BULLETIN SW10
Thermowells
Thermowells must be used on any application where the stem of the temperature
switch may be exposed to pressure, corrosive fluids or high velocity. Additionally,
the use of a thermowell permits instrument
interchange or calibration check without
disturbing or closing down the process.
Ashcroft temperature switches have
bulb diameters to match 38 nominal bore
thermowells. The bulbs have a sensitive
portion length of 2 which can be used
with 212 U dimensioned thermowells or
longer. For maximum accuracy, a thermowells U dimension should be selected
to permit complete immersion of the sensitive portion plus 1 when measuring the
temperature of liquids; an extra 3 should
be allowed when measuring the temperature of gases.
Thermowell bushings should be used
with remote mount temperature switches.
We recommend the standard 3 bulb and
code 69 Series bushings for use with any
thermowell U dimension. A split rubber
grommet allows easy installation and S
dimension adjustment.
Nominal Range(1)
F
40
0
75
150
235
350
500
to
to
to
to
to
to
to
60
100
205
260
375
525(3)
750(2)
NOTES:
BULLETIN SW10
40
20
20
65
110
175
260
to
to
to
to
to
to
to
160
400
95
125
190
275
400
20, 26, 27
21, 24, 31
400
400
400
400
500
700
900
1.0-2.0
1.5-3.0
1.5-3.5
1.5-3.0
1.5-3.5
2.0-4.5
4.0-8.0
3.0-8.0
5.0-12.0
8.0-16.0
5.0-12.0
5.0-12.0
8.0-16.0
16.0-30.0
50
1.5-5.5
2.2-8.5
2.5-12.0
2.2-8.5
2.5-8.5
3.2-12.0
7.2-24.0
22
32, 42
1.4-6.0
1.5-7.5
2.0-9.0
2.0-9.0
2.0-9.0
2.5-10.0
5.0-23.0
8.0-16.0
9.0-20.0
10.0-24.0
10.0-24.0
10.0-24.0
15.0-34.0
30.0-50.0
4 Dual switch element multiply single switch element value by 1.6 for
approximate deadband.
5 Set and reset points must fall within the adjustable range.
of construction.
All standard models feature 1 percent of
range setpoint repeatability and a minimum of
400 percent of range proof pressures.
These standard designs perform well in applications where shock and vibration could be a
problem and may be used in conjunction with
Ashcroft diaphragm seals in extreme services
such as slurries or abrasive process fluids.
PRESSURE/VACUUM SWITCHES
Overpressure Ratings
Proof psi
Burst psi
Nominal Range(1)
Vacuum
30 Hg
Compound
15 H2O/
15 H2O
30 H2O/
30 H2O
30 Hg/
15 psi
30 Hg/
30 psi
30 Hg/
60 psi
Pressure
10 H2O
30 H2O
60 H2O
100 H2O
150 H2O
15 psi
30 psi
60 psi
100 psi
200 psi
400 psi
600 psi
1000 psi
3000 psi
760mm Hg
-100 kPa
250
400
0.3-0.7
1.5-3.0
0.5-2.2
0.4-1.5
2.1-4.2
375mm H2O/
375mm H2O
760mm H2O/
760mm H2O
760mm Hg/
1.0 kg/cm2
760mm Hg/
2.0 kg/cm2
760mm Hg/
4.0 kg/cm2
3.7 kPa/
3.7 kPa
7.5 kPa/
7.5 kPa
100 kPa/
100 kPa
100 kPa/
200 kPa
100 kPa/
400 kPa
20
35
20
35
250
400
250
400
250
400
0.15-.75/
0.15-.75
0.30-.60/
0.30-.60
0.5-1.0/
0.3-0.7
1.0-1.5/
0.3-0.8
2.0-3.0/
0.7-1.5
1.5-2.5/
1.5-2.5
1.5-2.5/
1.5-2.5
2.0-3.0/
0.5-1.5
3.0-6.0/
1.0-2.0
5.0-9.0/
3.0-5.0
0.45-2.0/
0.45-2.0
0.45-2.0/
0.45-2.0
0.75-2.5/
0 .5-1.0
1.2-4.5/
0.7-1.5
2.5-7.0/
1.1-4.0
0.5-1.2/
0.5-1.2
0.5-1.5/
0.5-1.5
0.7-1.8/
0.7-1.4
1.4-2.4
0.4-1.3
2.8-4.5
1.0-2.3
2.1-3.5/
2.1-3.5
2.1-3.5/
2.1-3.5
2.8-4.2/
0.7-2.1
4.2-8.4/
1.4-2.8
7.0-12.0/
4.2-7.0
250mm H2O
750mm H2O
1500mm H2O
2500mm H2O
3750mm H2O
1.0 kg/cm2
2.0 kg/cm2
4.0 kg/cm2
7.0 kg/cm2
14 kg/cm2
28 kg/cm2
42 kg/cm2
70 kg/cm2
210 kg/cm2
2.5 kPa
7.5 kPa
15 kPa
25 kPa
37 kPa
100 kPa
200 kPa
400 kPa
700 kPa
1400 kPa
2800 kPa
4200 kPa
7000 kPa
2100 kPa
20
20
20
20
20
500
500
500
1000
1000
2400
2400
12000
12000
35
35
35
35
35
1500
1500
1500
3000
3000
3000
3000
18000
18000
0.2-0.5
0.3-0.6
0.5-1.3
0.6-1.6
1.0-2.5
0.1-0.35
0.1-0.50
0.3-1.0
0.5-1.7
1-3
4-7.5
4-11
7-30
15-60
1.0-2.0
1.5-2.5
1.5-3.5
2.5-5.5
4.5-8.5
0.5-1.5
0.5-1.5
1.0-3.5
1.5-5.0
5-13
5-24
9-30
30-110
80-235
0.35-1.5
0.45-2.0
0.9-2.5
1.1-4.0
1.7-6.5
0.2-1.0
0.3-1.0
0.7-2.5
1.1-3.5
2-9
5.5-15
7-20
18-70
37-160
0.4-1.0
0.5-2.0
0.7-3.0
1.0-4.0
2.0-6.0
0.4-1.0
0.4-1.0
0.6-2.0
1.0-4.5
3.0-7.5
4.0-11.0
5.0-23.0
15-80
30.0-230
1.4-2.8
2.1-3.5
2.1-5.0
3.5-7.7
6.0-12.0
0.7-2.1
0.7-2.1
1.4-5.0
2.1-7.0
7.0-18.2
7.0-33.6
12.6-42
42-154
112-329
30 H2O
60 H2O
100 H2O
150 H2O
15 psid
30 psid
60 psid
100 psid
200 psid
400 psid
600 psid
Nominal Range(1)
750mm H2O
1500mm H2O
2500mm H2O
3750mm H2O
1.0 kg/cm2
2.0 kg/cm2
4.0 kg/cm2
7.0 kg/cm2
14.0 kg/cm2
28.0 kg/cm2
42 0 kg/cm2
Pressure Ratings
Static Working Pressure Proof psi
5.4
21.6
5.4
21.6
5.4
21.6
5.4
21.6
500
2000
500
2000
500
2000
1000
4000
1000
4000
1000
8000
1000
8000
7.5 kPa
15 kPa
25 kPa
37 kPa
100 kPa
200 kPa
400 kPa
700 kPa
1400 kPa
2800 kPa
4200 kPa
21, 24, 31
1.5-2.5
1.5-3.5
2.5-5.5
4.5-8.5
2.0-5.0
2.0-5.0
3.0-6.0
11.0-20.0
12.0-40.0
20.0-60.0
80.0-150.0
50
0.45-2.0
0.9-2.5
1.1-4.0
1.8-6.5
0.7-3.5
1.5-3.5
3.0-4.5
7.0-15.0
10.0-26.0
15.0-40.0
30.0-115.0
22
32, 42
0.5-2.0
2.1-3.5
0.7-3.0
2.1-5.0
1.0-4.0
3.5-7.7
2.0-6.0
6.3-12.0
0.7-1.4
2.8-7.0
1.4-2.8
2.8-7.0
2.8-5.6
4.2-8.5
6.0-14.0 16.0-28.0
7.0-21.0 17.0-56.0
14.0-28.0 28.0-84.0
30.0-56.0 112.0-210.0
NOTES:
BULLETIN SW10
1 Switches may generally be set between 15% and 100% of nominal range
on increasing pressure. Consult factory for applications where setpoints
must be lower.
2 All deadbands are given in English units as shown in the nominal range
column. Deadbands shown are for switches with Buna N diaphragm.
Approximate deadbands for optional diaphragms:
Viton:
Teflon:
Stainless Steel:
Monel:
Dual Switch Element:
B 4
2 0
X P K
600 PSI
1 ENCLOSURE
B4
B7
D4
D7
Range
Process
Temperature
Limits F(9)
0 to 150
20 to 300
0 to 150
0 to 300
0 to 300
3000
psi
4 OPTIONS
5 RANGE
25(2)
29(5)
31
32
42
50
61(7)
62(7)
63
64
NOTES:
1 Standard switch.
2 Not available with psid ranges.
3 Dual switches are 2 SPDT snap-action switches, not independently
adjustable.
4 Wires cannot be terminated inside B400 switch enclosure.
5 Not available with type 700 enclosure.
6 Estimated dc. rating, 2.5A, 28 Vdc (not
UL listed).
7 Estimated dc rating, 0.4A, 120 Vdc (not UL listed).
8 Available on pressure only.
9 Ambient operating temperature limits 20 to 150F, all styles, setpoint
shift of 1% of range per 50F temperature change is normal.
Switches are calibrated at 70F reference.
BULLETIN SW10
23
24(1)
26(7)
27
28(5)
3 ACTUATOR SEAL
Code
and
Material
B Buna-N
V Viton
T Teflon
S 316L(8)
P Monel(8)
Order
Code
20(7)
21
22(6)
65
67(4,6)
68(4)
70
71(4)
Switch Elements
UL/CSA Listed SPDT
Narrow deadband ac
15A, 125/250 Vac
Ammonia service
5A, 125/250 Vac
Hermetically sealed switch, 5A, 125/250 Vac
narrow deadband
Heavy duty ac
22A, 125/250 Vac
General purpose
15A, 125/250/480 Vac
12A, 125 Vdc
14A, 250 Vdc; 6A, 30 Vdc
Heavy duty dc
10A, 125 Vac or dc,
18 HP, 125 Vac or dc
Sealed environment proof
15A, 125/250 Vac
High temperature 300F
15A, 125/250 Vac
Manual reset trip on
15A, 125/250 Vac
increasing
Manual reset trip on
15A, 125/250 Vac
decreasing
Low level (gold) contacts
1A, 125 Vac
Hermetically sealed switch, 11A, 125/250 Vac
general purpose
5A, 30 Vdc
Hermetically sealed switch, 1A, 125 Vac
gold contacts
Variable deadband
15A, 125/250 Vac
UL/CSA Listed Dual (2 SPDT)
Dual narrow deadband
15A, 125/250 Vac
Dual sealed environment
15A, 125/250 Vac
proof
Dual high temp. 300F
15A, 125/250 Vac
Dual general purpose
15A, 125/250/480 Vac
12A, 125 Vdc
14A, 250 Vdc
Dual ammonia service
5A, 125/250 Vac
Dual hermetically sealed
5A, 125/250 Vac
switch, narrow deadband
Dual hermetically sealed
11A, 125/250 Vac
switch, general purpose
5A, 30 Vdc
Dual low level gold contacts 1A, 125 Vac
Dual hermetically sealed
1A, 125 Vac
switch, gold contacts
T 4
2 0
1 ENCLOSURE
T4
T7
23
24(1)
25
26(7)
27
28(5)
29(5)
31
32
42
50
61(7)
62(7)
63
64
65
67(4,6)
68(4)
70
71(4)
Switch Elements
UL/CSA Listed SPDT
Narrow deadband ac
15A, 125/250 Vac
Ammonia service
5A, 125/250 Vac
Hermetically sealed switch,
5A, 125/250 Vac
narrow deadband
Heavy duty ac
22A, 125/250 Vac
General purpose
15A, 125/250/480 Vac
1
2A, 125 Vdc
1
4A, 250 Vdc; 6A, 30 Vdc
Heavy duty dc
10A, 125 Vac or dc,
1
8 HP, 125 Vac or dc
Sealed environment proof
15A, 125/250 Vac
High temperature 300F
15A, 125/250 Vac
Manual reset trip on
15A, 125/250 Vac
increasing
Manual reset trip on
15A, 125/250 Vac
decreasing
Low level (gold) contacts
1A, 125 Vac
Hermetically sealed switch,
11A, 125/250 Vac
general purpose
5A, 30 Vdc
Hermetically sealed gold
1A, 125 Vac
contacts
Variable deadband
15A, 125/250 Vac
UL/CSA Listed Dual (2 SPDT)
Dual narrow deadband
15A, 125/250 Vac
Dual sealed environment
15A, 125/250 Vac
proof
Dual high temp. 300F
15A, 125/250 Vac
Dual general purpose
15A, 125/250/480 Vac
1
2A, 125 Vdc
1
4A, 250 Vdc
Dual ammonia service
5A, 125/250 Vac
Dual hermetically sealed
5A, 125/250 Vac
switch, narrow deadband
Dual hermetically sealed
11A, 125/250 Vac
switch, general purpose
5A, 30 Vdc
Dual low level gold contacts
1A, 125 Vac
Dual hermetically sealed
1A, 125 Vac
switch, gold contacts
BULLETIN SW10
Order Code
System Material
Style
TS
3l6 SS
Remote Mount
Rigid
Order Code
T05
T10
T15
T20
T25
System Material
316
316
316
316
316
Line Length
Style(9)
5
10
15
20
25
Capillary
with
302 SS
Spring
Armor
SS
SS
SS
SS
SS
Minimum
S
Thermowell
Dimension
U Dimension
234
4
212
6
412
9
712
12
1012
Remote Mount
3
212
5 OPTIONS
Use table on page 7
6 STANDARD TEMPERATURE
RANGE SELECTION
Adjustable Range
F
C
40 to 600
40 to 160
0 to 100
20 to 400
75 to 205
20 to 95
150 to 260
65 to 125
235 to 375
110 to 190
350 to 525
175 to 275
500 to 750(2)
260 to 400
NOTES:
1 Standard switch.
2 Available with remote mount thermal systems only.
3 Dual switches are 2 SPDT snap-action switches, not independently
adjustable.
4 Wires cannot be terminated inside T400 switch enclosure.
5 Not available with Type 700 enclosure.
6 Estimated dc rating, 2.5A, 28 Vdc (not UL listed).
7 Estimated dc rating, 0.4A, 120 Vdc (not UL listed).
8 Not available on 350 to 525F.
9 Consult factory on remote mount for bulb lengths other than 3.
H 4
2 4
X F S
3000 PSI
1 ENCLOSURE
Hydraulic pressure switch, Type 400, watertight
enclosure meets NEMA 3, 4, 4X, 13 and IP66
requirements.
H4
25
26(3)
27
28
29
32
42
61(3)
62(3)
63
64
65
70
Switch Elements
UL/CSA Listed SPDT
Narrow deadband ac
15A, 125/250 Vac
Ammonia service
5A, 125/250 Vac
Hermetically sealed switch, 5A, 125/250 Vac
narrow deadband
Heavy duty ac
22A, 125/250 Vac
General purpose
15A, 125/250/480 Vac
12A, 125 Vdc
14A, 250 Vdc; 6A, 30 Vdc
Heavy duty dc
10A, 125 Vac or dc,
18 HP, 125 Vac or dc
Sealed environment proof
15A, 125/250 Vac
High temperature 300F
15A, 125/250 Vac
Manual reset trip on
15A, 125/250 Vac
increasing
Manual reset trip on
15A, 125/250 Vac
decreasing
Hermetically sealed switch, 11A, 125/250 Vac
general purpose
5A, 30 Vdc
Hermetically sealed switch, 1A, 125 Vac
gold contacts
UL/CSA Listed Dual (2 SPDT)
Dual narrow deadband
15A, 125/250 Vac
Dual sealed environment
15A, 125/250 Vac
proof
Dual high temp. 300F
15A, 125/250 Vac
Dual general purpose
15A, 125/250/480 Vac
12A, 125 Vdc
14A, 250 Vdc
Dual ammonia service
5A, 125/250 Vac
Dual low level, gold contacts 1A, 125 Vac
BULLETIN SW10
3 ACTUATOR SEAL
Code
Process
and
Temperature
Material Limits F(4)
V Viton
20 to 300
Viton O-Ring,
Stainless Steel
Pressure
Connection
4 OPTIONS
Use table from page 7
5 STANDARD
PRESSURE RANGE
Range
psi
Adjustable
Setpoint
Limits psi
Proof
Pressure
psi
1000
2000
3000
5000
7500
150-1000
300-2000
450-3000
750-5000
1125-7500
12,000
12,000
12,000
10,000
100,000
NOTES:
1 Standard switch.
2 Dual switches are 2 SPDT snap-action switches, not
independently adjustable.
3 Estimated dc rating, 0.4A, 120 Vdc (not UL listed).
4 Ambient operating temperature limits 20 to 150F, all
styles, setpoint shift of 1% of range per 50F temperature
change is normal. Switches are calibrated at 70 F reference.
Code
XBP
XBX
XCH
XC8
XCN
XD2
XFM
XFP
XFS
XG3
XG5
XG6
XG7
XG8
XG9
XHS
XHX
XJK
XJL
XJM
XK3
XLE
XNH
XNN
XPK
XPM
XTA
XTM
XUD
XUX
X06
X07
X6B
Description
BULLETIN SW10
11
18
17
17
6
7
8
9
10
11
12
13
14
15
16
17
18
2
16,17
1, 17
1, 17
13
7
7
15
Notes
1
2
3
4
5
10
3
0.22
(6)
4.03
(102)
1.25
(32)
2.27
(58)
0.22
(6)
0.25
(6)
1.25
(32)
3.32
(84)
2.77
(70)
3.26
(83)
5.95
(151)
0.25
(6)
2.77
(70)
3.32
(84)
5.68
(144)
(58)
4.03
(102)
1.25
(32)
0.34
2 HOLES
0.36
(9)
2.50
(64)
0.14
(4)
3/4 NPT
3.06
(78)
1.39
(35)
2.78
(71)
0.50
(13)
2.31
(59)
3.26
(83)
5.62
(143)
3.50
(89)
2.27 (58)
2.27
(58)
0.22
(6)
4.03
(102)
0.28 X 3 HOLES
(7)
1.25
(32)
1.25
(32)
4.03
(102)
3.32
(84)
BRACKET WHEN
REQURIED XBP
VARIATION
1/4 NPT
FEMALE
5.12
(130)
0.22
(6)
2.84
(72)
3/4 NPT
5.11
(130)
0.28 X 3 HOLES
(7)
0.25
(6)
0.25
(6)
2.77
(70)
3.32
(84)
2.77
(70)
3.26
(83)
6.07 (154)
2.99
(76)
3/4 NPT
7.16
(182)
0.34
2 HOLES
L
1.55
(39)
1/4 NPT
FEMALE HIGH
PRESSURE PORT
0.50 (13)
1/4 NPT
FEMALE LOW
PRESSURE PORT
0.36 (9)
1.39
(35)
3.26
(83)
3.06
(78)
2.78 (71)
2.31
(59)
3.50 (89)
BRACKET WHEN
REQURIED XBP VARIATION
2.27
(58)
2.27
(58)
1.25
(32)
4.03 (102)
0.25
(6)
3.32
(84)
1/4 NPT
FEMALE
5.62
(143)
5.12 (130)
0.22
(6)
2.96 (75)
3/4 NPT
1.57 (40)
4.03 (102)
1.25
(32)
0.25
(6)
3.32
(84)
2.77
(70)
4.61
(117)
2.77
(70)
4.61
(117)
2.00
(51)
3/4 NPT
2.00
(51)
3/4 NPT
7/8 HEX
2.31 (59)
3.26 (83)
2.31
(59)
ACTIVE BULB
LENGTH
BULLETIN SW10
2.31 (59)
3.26 (83)
0.37
(9)
2.31
(59)
ACTIVE BULB
LENGTH
2.50
(64)
0.37
(9)
3.00
(76)
0.28 x 3 HOLES
(7)
3.58
(91)
5.20
(132)
1.22
(31)
2.18
(55)
3.58
(91)
5.20
(132)
1.22 (31)
2.18
(55)
0.03
(1)
0.03
(1)
0.32
(8)
0.32
(8)
3.62
(92)
3.62
(92)
3.90
(99)
5.73
(146)
1.37
(35)
3.90
(99)
6.43
163
0.31
(8)
1.11
(28)
0.31 (8)
1.93
(49)
4.37
(111)
3/4 NPT
2 HOLES
1.37
(35)
3/4 NPT 2 HOLES
1.93
(49)
2.31
(59)
0.36
(9)
4.37
(111)
1.39
(35)
0.50
(13)
0.34 X 2 HOLES
(9)
0.36
(9)
2.78
(71)
3.50
(89)
3.06
(78)
5.62
(143)
1/4 NPT FEMALE
BRACKET WHEN
REQUIRED "XBP"
VARIATION
5.12
(130)
0.28 x 3 HOLES
(7)
5.20
(132)
3.58 (91)
5.20 (132)
3.58
(91)
0.03
(1)
2.18
(55)
2.18
(55)
0.31
(8)
3.62
(92)
3.62
(92)
3.90
(99)
1.37
(35)
3.90
(99)
6.43
(163)
0.31 (8)
4.37
(111)
3.09
(78)
0.03
(1)
0.32
(8)
0.32
(8)
1.37
(35)
1.22 (31)
1.93
(49)
7.78
(198)
L
3/4 NPT
2 HOLES
1.39
(35)
0.36
(9)
1.43
(36)
0.50
(13)
2.31
(59)
3.06
(78)
1.11
(28)
0.36 (9)
5.62
(143)
2.78 (71)
3.50 (89)
1.93
(49)
5.12 (130)
BRACKET WHEN
REQUIRED "XBP" VA
4.37
(111)
5.20
(132)
3.58
(91)
3.58
(91)
2.18
(55)
1.22
(31)
0.32
(8)
5.20
(132)
0.03
(1)
3.60 (91)
5.23
(133)
0.31
(8)
3.61
(92)
1.37
(35)
4.37
(111)
7/8 HEX
1/2 NPT MALE
1.31
(33)
2.31
(59)
ACTIVE BULB
LENGTH
3.90
(99)
5.23
(133)
2.31
(59)
0.31 (8)
1.37
(35)
0.37
(9)
BULLETIN SW10
0.03
(1)
0.32
(8)
3.90
(99)
1.93
(49)
1.22 (31)
2.18
(55)
0.28 x 3 HOLES
(7)
2.31
(59)
ACTIVE BULB
LENGTH
2.50
(64)
L
3.00
(76)
0.37
(9)
BULLETIN SW10