Você está na página 1de 128

Greenheck Quick Delivery

Stock & Quick Build Catalog


Volume 22

This catalog is being sent to you on behalf of:

ction
Sele
ctionn-Based eory
Sele
Th
Fan pplicatiomance
A
or
Perf

Fans
Roof Exhaust Direct Drive - G
Model G Centrifugal Roof Exhaust fans are direct drive. These fans are specifically designed for roof mounted applications
exhausting relatively clean air. Fan wheels are centrifugal, backward inclined, and constructed of aluminum.

PERFORMANCE

C*

Performance capabilities
range from 73 cfm to
4,295 cfm and up to 1 in.
wg of static pressure.

1 3/4 in.
A

G CONDENSED PERFORMANCE &


DIMENSIONAL DATA
MODEL

C*

ROOF
OPENING

G-060

17

193/8

121/8

10 x 10

17

193/8

121/8

10 x 10

G-070

17

193/8

121/8

10 x 10

G-075

17

193/8

121/8

10 x 10

G-080

17

21

145/8

12 x 12

G-085

17

21

145/8

12 x 12

G-090

17

21

145/8

12 x 12

17

21

145/8

12 x 12

G-101

19

245/8

20

14 x 14

G-121

19

245/8

20

14 x 14

G-131

22

287/8

20

18 x 18

G-141

22

287/8

20

18 x 18

G-150

26

35

211/8

18 x 18

G-160

30

35

215/8

20 x 20

G-170

30

35

215/8

20 x 20

G-180

30

35

22

20 x 20

G-065

DAMPER
SIZE

Performance for available IN STOCK SIZES is shown on page 5


IN STOCK
SIZES ()

8x8

10 x 10

G-095

12 x 12

16 x 16

18 x 18

MIN/MAX
RPM
1050
1550
1050
1550
1050
1550
1050
1550
1050
1550
1050
1550
1050
1550
1050
1550
860
1725
860
1725
860
1725
860
1140
860
1140
860
1140
860
1140
860
1140

SONES @
0 in.
1.7
4.2
2.2
4.9
2.7
5.6
3.6
6.1
3.8
7.3
4.0
7.6
4.0
7.6
5.4
9.6
4.3
12.1
5.6
14.1
6.5
19.2
6.8
10.4
7.9
11.7
8.0
13.6
9.7
16.3
12.1
19.5

PERFORMANCE
0
.125
.25
138
73
203
166
120
187
110
276
232
176
254
179
374
327
274
296
200
438
377
310
335
249
134
495
439
379
399
307
179
588
529
464
520
420
292
768
700
633
717
569
389
1059 969
863
766
588
239
1536 1454 1374
922
723
449
1849 1753 1659
1193 1011 771
2393 2310 2222
1376 1160 919
1824 1667 1498
1772 1552 1305
2348 2184 2016
2008 1783 1535
2662 2489 2319
2572 2329 2077
3409 3226 3042
3240 3002 2733
4295 4122 3933

IN INCHES WG
.5
.75
1

238
308
472
623
1181

974

1453 1223
2030 1820 1555
1112
1629
552
1932
1417
2647
1978
3509

1115
1411
2182 1458
2971 2247

*May be greater depending on motor. All dimensions in inches.


Dimension A - given is the inside dimensions of the curb cap.
The roof curb should be 1 in. less than the curb cap to allow for roofing and flashing.
Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include
the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA
Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

For complete product information


refer to catalog Model G and GB, or
contact your local representative.
4

FANS

Greenheck Fan Corporation certifies that the G


models shown herein are licensed to bear the
AMCA Seal. The ratings shown are based on tests
and procedures performed in accordance with
AMCA Publication 211 and AMCA Publication 311
and comply with the requirements of the AMCA
Certified Ratings Program.

UL/cUL 705
E40001 - G

Roof Exhaust Belt Drive - GB


Model GB Centrifugal Roof Exhaust fans are belt drive. These fans are specifically designed for roof mounted applications
exhausting relatively clean air. Fan wheels are centrifugal, backward inclined, and constructed of aluminum. Adjustable motor
pulleys allow for final system balancing.
B

PERFORMANCE

C*

GB CONDENSED PERFORMANCE
RANGES & DIMENSIONAL DATA
B

ROOF
OPENING

MODEL

C*

GB-071

19

243/8 23

14 x 14

GB-081

19

243/8 23

14 x 14

GB-091

19

243/8 23

14 x 14

GB-101

19

243/8 23

14 x 14

GB-121

19

243/8 23

14 x 14

GB-131

19

283/8 23

14 x 14

GB-141

22

283/8 23

18 x 18

GB-161

22

283/8 23

18 x 18

GB-180

30

35

28

20 x 20

GB-200

30

35

28

20 x 20

GB-220

34

42 31

26 x 26

GB-240

34

42 31

26 x 26

GB-260

40

50

36

32 x 32

GB-300

40

50

36

32 x 32

GB-330

46

58 38

38 x 38

GB-360

46

58 38

38 x 38

GB-420

52

65

44 x 44

GB-480

58

73 47

GB-500

64

83

50

56 x 56

GB-540

64

83

50

56 x 56

44

50 x 50

Performance capabilities
range from 140 cfm to
44,690 cfm and up to 2.0
in. wg of static pressure.

13/4 in.

Performance for available IN STOCK SIZES is shown on pages 8 & 9

PERFORMANCE IN INCHES WG
DAMPER IN STOCK MIN/MAX SONES @
SIZE
SIZES ()
RPM
0 in.
0
.25
.5
.75
1
1.25
1.5
600
1.2
131
68

1710
11.1
372
334
292
245
198
600
2.2
301
175

1710
12.5
856
784
710
629
480
600
2.7
455
271

1710
13.4
1295 1179 1061
934
785
12 x 12
700
3.7
593
455

1800
13.2
1525 1418 1320 1208 1064
793
595
3.3
721

1725
17.4
2093 1984 1871 1743 1600 1426
595
4.5
844
655

1685
16.9
2391 2278 2157 2020 1857 1654
525
4.4
974
709

1705
20
3163 3020 2883 2739 2574 2370
16 x 16
478
4.7
1412 1030

1375
21
4062 3815 3571 3304 3007 2609 2073
495
4.3
1924 1150

1460
26
5677 5514 5335 5155 4938 4698 4426
18 x 18
440
6.5
2434

1200
24
6640 6336 5968 5650 5274 4828 4177
330
6.6
2507
985
23
7484 7212 6898 6568 6106 5547 4883
24 x 24
425
5.9
3902 3422 2691

910
24
8355 7916 7467 6932 6240 5388 3707
270
7.7
3487
835
23
10784 10292 9794 9225 8606 7932 7157
30 x 30
300
9.3
4859 3976

890
28
14416 13897 13335 12716 12072 11379 10536
255
5.2
6159
700
28
16908 16185 15408 14564 13624 12640 11538
36 x 36
215
4.8
5750
685
30
18321 17560 16711 15773 14710 13534 12119
180
2.5
7417
42 x 42
600
30
24724 23765 22709 21620 20103 18584 16590
150
5.6
9015
48 x 48
485
31
29148 27622 26016 24290 22106 19516
160
5.9
12893
460
33
37068 34991 32805 30342 27917 25310
54 x 54
160
6.3
14160
505
40
44694 43221 41157 38813 36503 33869 31293

1.75

2.0

4123

3765

3077

6024

4294

9568

7963

10184

26758

*May be greater depending on motor. All dimensions in inches. Dimension A - given is the inside dimensions of the curb cap.
The roof curb should be 1 in. less than the curb cap to allow for roofing and flashing.
Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the
effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301.
Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

For complete product information


refer to catalog Model G and
GB, or contact your local
representative.
6

FANS

Greenheck Fan Corporation certifies that the GB


models shown herein are licensed to bear the
AMCA Seal. The ratings shown are based on tests
and procedures performed in accordance with
AMCA Publication 211 and AMCA Publication 311
and comply with the requirements of the AMCA
Certified Ratings Program.

UL/cUL 705
E40001 - GB

GB Performance Data - In Stock


Stock Model GB fans include galvanized birdscreen, disconnect switch, UL/cUL 705 Electrical.

Order stock products online at


www.greenheck.com/qd
MODEL

HP

GB-071-4X-QD-R2
873-1256 RPM
1/4 HP, 115/60/1 ODP

GB-071-4X-QD-R3
1221-1710 RPM
1/4 HP, 115/60/1 ODP
GB-081-4X-QD-R2
873-1256 RPM
1/4 HP, 115/60/1 ODP

GB-081-4X-QD-R3
1221-1710 RPM
1/4 HP, 115/60/1 ODP
GB-091-4X-QD-R2
863-1256 RPM
1/4 HP, 115/60/1 ODP

GB-091-4X-QD-R3
1221-1710 RPM
1/4 HP, 115/60/1 ODP
GB-101-4X-QD-R3
1056-1400 RPM
1/4 HP, 115/60/1 ODP
GB-101-4X-QD-R4
1324-1688 RPM
1/4 HP, 115/60/1 ODP
GB-101-LMDX-QD
588-1800 RPM

GB-121-4X-QD
980-1395 RPM
1/4 HP, 115/60/1 ODP
GB-121-LMDX-QD
595-1550 RPM

GB-131-LMDX-QD
540-1685 RPM

1/3

GB-141-5X-QD
1049-1360 RPM
1/2 HP
115/208-230/60/1
ODP
GB-141-LMDX-QD
450-1545 RPM

SONES @
0 IN.

MAX
BHP

600

1757

1.2

0.006

131

68

939

2750

3.4

0.021

205

169

127

1247

3652

6.5

0.05

272

246

1556

4558

9.3

0.098

339

1710

5009

11.1

0.13

373

600

1757

2.2

0.008

301

175

939

2750

4.7

0.031

470

404

330

1247

3652

7.6

0.073

625

575

1556

4558

10.8

0.14

779

1710

5009

12.5

0.19

856

600

1757

2.7

0.011

455

271

939

2750

5.7

0.042

711

1247

3652

9.2

0.098

1556

4558

11.8

1710

5009

13.4

.125

.25

.375

.5

.625

.75

217

185

154

109

319

296

274

248

353

335

312

292

223

197

120

269

246

198

525

470

403

284

740

700

660

615

571

517

821

785

748

710

669

630

606

490

263

945

866

785

698

604

454

0.19

1179

1116

1052

988

919

848

772

504

0.25

1296

1238

1180

1122

1062

999

934

785

511

700

2039

3.7

0.020

593

455

1165

3393

6.8

0.091

987

905

830

731

578

1400

4077

8.9

0.16

1186

1117

1051

989

909

810

633

1635

4761

11.1

0.25

1385

1325

1269

1214

1161

1094

1019

792

1800

5242

13.2

0.33

1525

1471

1418

1367

1320

1270

1208

1064

595

2035

3.3

0.021

722

542

820

2804

5.2

0.054

995

877

728

1045

3574

7.3

0.111

1268

1177

1078

962

805

1395

4770

12.5

0.25

1692

1625

1557

1484

1404

1315

1214

907

1/3

1550

5300

14.6

0.33

1880

1820

1759

1696

1629

1555

1475

1289

1725

5899

17.4

0.50

2093

2038

1984

1928

1871

1810

1743

1600

595

2044

4.5

0.024

844

655

720

2474

5.4

0.043

1022

879

650

960

3299

7.6

0.103

1362

1262

1144

990

1315

4518

13.2

0.26

1866

1794

1718

1637

1545

1435

1305

1/3

1440

4948

15.0

0.35

2044

1978

1911

1838

1759

1674

1571

1299

1685

5790

16.9

0.56

2391

2335

2279

2219

2158

2093

2020

1857

525

2010

4.4

0.030

974

709

710

2718

5.7

0.074

1317

1147

908

920

3522

7.7

0.16

1706

1576

1439

1258

961

GB-141-4X-QD
614-865 RPM
1/4 HP, 115/60/1 ODP
GB-141-3X-QD
906-1170 RPM
1/3 HP, 115/60/1 ODP

TS

GB-131-4X-QD
942-1315 RPM
1/4 HP, 115/60/1 ODP
GB-131-5X-QD
1299-1685 RPM
1/2 HP,
115/208-230/60/1
ODP

PERFORMANCE IN INCHES WG

RPM

1075

4115

10.0

0.26

1994

1881

1771

1646

1489

1265

1/3

1170

4479

11.4

0.34

2170

2066

1966

1858

1733

1574

1355

1360

5207

14.6

0.53

2522

2433

2346

2258

2166

2062

1942

1602

1545

5915

17.6

0.78

2866

2787

2709

2634

2556

2475

2384

2176

1705

6528

20

1.03

3163

3091

3020

2952

2883

2811

2739

2574

Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects
of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown
are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

FANS

GB Performance Data - In Stock


Stock Model GB fans include galvanized birdscreen, disconnect switch, UL/cUL 705 Electrical.

Order stock products online at


www.greenheck.com/qd
MODEL

HP

GB-161-4X-QD
634-865 RPM
1/4 HP
115/60/1 ODP

GB-161-5X-QD
852-1100 RPM
1/2 HP
115/208-230/60/1 ODP
GB-161-LMDX-QD
425-1375 RPM

PERFORMANCE IN INCHES WG

RPM

TS

SONES
@ 0 IN.

MAX
BHP

.125

478

2080

4.7

0.044

1412

1030

625

2720

6.4

0.097

1846

1574

1221

865

3764

10.6

0.26

2555

2359

2162

.25

.375

.5

1932

1624

.625

.75

1/3

945

4113

12.6

0.34

2791

2612

2433

2236

2009

1692

1100

4787

15.3

0.53

3249

3094

2943

2786

2614

2428

2197

1250

5440

17.9

0.79

3692

3556

3421

3288

3149

2997

2838

2443

1375

5984

21

1.05

4062

3938

3815

3694

3571

3444

3304

3007

495

2397

4.3

0.078

1924

1645

1150

730

3535

7.4

0.26

2838

2667

2469

2212

1882

810

3923

8.8

0.35

3149

2997

2832

2623

2375

2052

940

4552

12.7

0.55

3655

3526

3387

3234

3052

2843

2600

1055

5109

16.2

0.77

4102

3989

3866

3741

3596

3432

3251

2811

1185

5739

19.0

1.1

4607

4507

4400

4290

4179

4045

3900

3575

1335

6465

22

1.54

5191

5102

5010

4912

4814

4715

4599

4343

1460

7071

26

1.97

5677

5595

5514

5424

5335

5245

5155

4938

440

2462

6.5

0.103

2434

1975

600

3357

8.5

0.26

3320

2984

2637

2088

1/3

665

3721

9.6

0.35

3679

3378

3084

2705

2087

770

4308

12.1

0.55

4260

4013

3744

3477

3140

2643

860

4812

14.1

0.77

4759

4548

4289

4068

3810

3504

3085

1.5

2073

GB-180-5X-QD
676-940 RPM
1/2 HP
115/208-230/60/1 ODP
GB-180-LMDX-QD
495-1460 RPM

1/3

4426

3765

GB-200-LMDX-QD
440-1200 RPM

965

5400

16.7

1.09

5340

5157

4927

4719

4519

4285

4015

3239

1090

6099

20

1.57

6031

5870

5681

5473

5301

5123

4924

4449

1200

6715

24

2.09

6640

6493

6336

6144

5968

5812

5650

5274

425

2726

5.9

0.21

3902

3422

2691

460

2950

6.7

0.26

4223

3784

3188

4177

GB-240-LMDX-QD
300-910 RPM

505

3239

7.8

0.35

4636

4241

3760

3059

585

3752

10.3

0.55

5371

5030

4665

4194

3562

2112

660

4233

13.1

0.79

6059

5756

5449

5093

4636

4073

3217

730

4682

15.8

1.06

6702

6427

6157

5861

5506

5076

4567

825

5291

19.7

1.54

7574

7331

7091

6844

6573

6261

5901

5002

910

5836

24

2.06

8355

8134

7916

7699

7467

7214

6932

6240

300

2395

9.3

0.19

4859

3976

365

2914

9.2

0.35

5912

5222

4339

420

3353

9.6

0.53

6803

6221

5536

4640

475

3792

11.4

0.77

7694

7197

6615

5954

1/3

GB-300-LMDX-QD
250-890 RPM

2036

1/3

3707

5094

530

4231

13.4

1.07

8584

8149

7639

7094

6455

5667

4194

600

4790

15.9

1.55

9718

9334

8906

8445

7951

7387

6721

665

5309

18.8

2.12

10771

10424

10059

9648

9228

8772

8268

760

6068

23

3.15

12310

12007

11703

11357

10996

10629

10241

9369

890

7106

28

5.05

14416

14157

13897

13638

13335

13027

12716

12072

7025

10536

7963

Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects
of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values
shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
FANS

H-GPF or SDCurb

A
1.75 in.
A
C
D
D
1.75 in.
A

A
B

Low Silhouette Roof Exhaust - LB/LBP


STANDARD CONSTRUCTION FEATURES

OPTIONS AND ACCESSORIES

Aluminum housing with hinged hood


Non-overloading backward inclined aluminum wheel
Curb cap with prepunched mounting holes
Motor and drives isolated on shock mounts
Birdscreen mounted to the discharge perimeter
Ball bearing motors
Adjustable motor pulley
Adjustable motor plate
Fan shaft mounted in ball bearing pillow blocks
Static free belts
Corrosion resistant fasteners
Nema-1 disconnect

Galvanized housing
Performance baffle (Direct drive models)
Gravity and motorized dampers
Galvanized and aluminum roof curbs
(See pages 114-115)
Curb seal
Curb adaptors
Aluminum birdscreen
Speed control (Direct drive models)
Relubricatable bearings
UL/cUL 705 Electrical
Dual Drives
NEMA 3R and EXP disconnect switches
Greenheck coatings (See coatings page 117)
B

D
1.75 in.
A
C

MODEL LBP

MODEL LB

1.75 in.
A
C

LB BELT DRIVE CONDENSED


PERFORMANCE RANGES & DIMENSIONAL DATA
B

ROOF
OPENING

LB-10 22 x 22 28

39

17

14 x 14

LB-14 26 x 26 35

39

18

18 x 18

LB-18 30 x 30 40

39

21

20 x 20

20 x 20

MODEL

LB-21 30 x 30 43 51 23

LB-24 34 x 34 45 51 23 6

26 x 26

LB-30 40 x 40 50 62 265/8 8

32 x 32

LB-36 46 x 46 60 62 325/8 9

38 x 38

LB-42 52 x 52 705/8 74 373/8 11 44 x 44


LB-48 58 x 58 703/8 67 41 115/8 50 x 50
LB-54 64 x 64 79 86 453/8 12 56 x 56

PERFORMANCE IN INCHES WG
DAMPER MIN/MAX SONES
SIZE
RPM
@ 0 in.
0
.125
.25
.5
.75
1
600
3.0
539
351
12 x 12
1767
13.5
1587 1533 1480 1385 1254 1112
480
4.1
903
614
16 x 16
1343
14.4
2525 2456 2372 2199 1979 1692
465
2.7
1753 1422
1460
24
5505 5417 5328 5138 4936 4714
18 x 18
465
6.6
2820 2420 1732
1165
25
7066 6940 6815 6474 6124 5678
355
5.8
3419 2806
24 x 24
910
27
8763 8549 8333 7889 7377 6713
230
8.0
3910 2576
30 x 30
835
27
14194 13914 13635 13062 12432 11728
220
5.2
6204 4803
36 x 36
678
25
19121 18770 18419 17621 16683 15636
190
6.1
8328 6455
42 x 42
515
24
22574 22037 21500 20214 18651 16871
150
5.4
9666 6546
48 x 48
420
23
27065 26278 25383 23363 21159 18029
130
4.6
12159
54 x 54
401
29
37506 36544 35583 33500 30332 26018

LBP BELT DRIVE CONDENSED


PERFORMANCE RANGES & DIMENSIONAL DATA
MODEL

LBP-10 22 x 325/8 39

28

15

LBP-14 26 x 26

40

32

15

LBP-18 30 x 30

46

353/8

24

LBP-21 30 x 30

46

36

24

LBP-24 34 x 34

49

40

23

LBP-30 40 x 40

58

46

26

LBP-36 46 x 46

63

LBP-42 52 x 52

70

58

38

LBP-48 58 x 58

76

64

403/8

LBP-54 64 x 64

83

70

435/8

513/4 343/8

PERFORMANCE IN INCHES WG
ROOF
DAMPER MIN/MAX SONES @
OPENING
SIZE
RPM
0 in.
0
.125
.25
.5
.75
1
600
3.0
539
351
14 x 14 12 x 12
1767
13.5
1587 1533 1480 1385 1254 1112
480
4.1
903
614
18 x 18 16 x 16
1343
14.4
2525 2456 2372 2199 1979 1692
465
2.7
1753 1422
20 x 20
1460
24
5505 5417 5328 5138 4936 4714
18 x 18
465
6.6
2820 2420 1732
20 x 20
1165
25
7066 6940 6815 6474 6124 5678
355
5.8
3419 2806
26 x 26 24 x 24
910
27
8763 8549 8333 7889 7377 6713
230
8.0
3910 2576
32 x 32 30 x 30
835
27
14194 13914 13635 13062 12432 11728
220
5.2
6204 4803
38 x 38 36 x 36
678
25
19121 18770 18419 17621 16683 15636
190
6.1
8328 6455
44 x 44 42 x 42
515
24
22574 22037 21500 20214 18651 16871
150
5.4
9666 6546
50 x 50 48 x 48
420
23
27065 26278 25383 23363 21159 18029
130
4.6
12159
56 x 56 54 x 54
401
29
37506 36544 35583 33500 30332 26018

All dimensions in inches.


Dimension A - given is
the inside dimensions of
the curb cap. The roof
curb should be 11/2 in.
less than the curb cap
to allow for roofing and
flashing. Performance
certified is for installation
type A: Free inlet, Free
outlet. Power rating
(BHP) does not include
transmission
losses.
Performance
ratings
include the effects of a
birdscreen. The sound
ratings
shown
are
loudness values in fan
sones at 5 ft. (1.5 m) in a
hemispherical free field
calculated per AMCA
Standard 301. Values
shown are for installation
type A: Free inlet fan
sone levels. The AMCA
Certified Ratings Seal
applies to sone ratings
only.

FANS

13

Upblast Roof Exhaust Direct Drive - CUE/CUE-HP


Model CUE Centrifugal Roof Exhaust fans are direct drive. These fans are specifically designed for roof mounted applications.
Exhaust air is discharged directly upward, away from the roof surface. Fan wheels are centrifugal, backward inclined and
constructed of aluminum.

PERFORMANCE

Performance capabilities
range from 130 cfm to
6,410 cfm and up to 1.5
in. wg of static pressure.
"

C*

1 3/4 in.
A

CUE CONDENSED PERFORMANCE RANGES


& DIMENSIONAL DATA
Performance for available IN STOCK SIZES is shown on page 15
B

C*

ROOF
OPENING

CUE-060 17

183/8

13

113/8

10 x 10

CUE-065 17

183/8

13

113/8

10 x 10

CUE-070 17

183/8

13

113/8

10 x 10

CUE-075 17

183/8

13

113/8

10 x 10

21

133/8

11

12 x 12

21

133/8

11

12 x 12

21

133/8

11

12 x 12
12 x 12

MODEL

CUE-080 19
CUE-085 19
CUE-090 19
CUE-095 19

21

15

137/16

CUE-098 19

247/8

28

173/8

14 x 14

CUE-101 19

247/8

28

173/8

14 x 14

CUE-121 19

247/8

28

173/8

14 x 14

CUE-131 19

247/8

28

173/8

14 x 14

CUE-141 22

287/8

29

193/8

18 x 18

CUE-161 22

287/8

29

193/8

18 x 18

CUE-180 30

233/8

285/8

21

20 x 20

CUE-200 30

233/8

285/8

21

20 x 20

PERFORMANCE IN INCHES WG
DAMPER IN STOCK MIN/MAX SONES @
SIZE ^ SIZES ()
RPM
0 in.
0
.125
.25
.5
.75
1.5
1050
1.7
133
81
1550
4.2
197 164
128
1050
2.2
180 109
1550
4.7
266 222
172
8x8
1050
2.6
250 171
1550
5.5
369 325
269
1050
3.4
287 188
1550
6.0
424 359
291
1050
3.8
325 247
133
1550
7.3
480 431
376
235
1050
4.0
389 305
182
1550
7.5
574 520
461
312
10 x 10
1050
4.1
549 451
306
1550
7.8
811 744
677
501
1050
5.3
711 570
381
1550
9.6
1049 964
861
616
860
8.4
588 409
1725
13.8
1180 1094 1017 824
586
860
4.6
732 625
481

1725
13.3
1468 1422 1373 1255 1129
12 x 12
860
5.3
1015 905
781

1725
15.6
2037 1979 1923 1816 1710 1176
860
8.5
1180 1057 914
1725
18.8
2366 2305 2244 2122 1994
860
7.3
1558 1427 1264
1725
26
3125 3066 3005 2865 2711 2085
16 x 16
860
10.7
2472 2315 2126 1680

1140
15.7
3277 3161 3035 2745 2421
860
12.3
3249 3074 2922 2474
1140
17.6
4307 4173 4045 3822 3470
18 x 18
860
15.7
4837 4587 4346 3815 3084
1140
24
6412 6224 6036 5674 5283 3445

*May be greater depending on motor. All dimensions in inches.


^Dampers should not be used in grease applications.
Dimension A - given is the inside dimensions of the curb cap.
The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing.
Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values
shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

For complete product information


refer to catalog Series C, or
contact your local representative.
14

FANS

Greenheck Fan Corporation certifies that the CUE


models shown herein are licensed to bear the
AMCA Seal. The ratings shown are based on tests
and procedures performed in accordance with
AMCA Publication 211 and AMCA Publication 311
and comply with the requirements of the AMCA
Certified Ratings Program.

UL/cUL 705
UL/cUL 762 (size 98 and up)
E40001 - CUE

Upblast Roof Exhaust Belt Drive - CUBE


Model CUBE Centrifugal Roof Exhaust fans are belt drive. These fans are specifically designed for roof mounted
applications. Exhaust air is discharged directly upward, away from the roof surface. Fan wheels are centrifugal, backward
inclined, and constructed of aluminum. Adjustable motor pulleys allow for final system balancing.

PERFORMANCE

C*

Performance capabilities
range from 258 cfm to
30,000 cfm and up to 5
in. wg of static pressure.

13/4 in.
A

CUBE CONDENSED PERFORMANCE


RANGES & DIMENSIONAL DATA Performance for available IN STOCK SIZES is shown on pages 18 & 19
MODEL

C*

CUBE-098 19 247/8 28 173/8


CUBE-101 19 247/8 28 173/8
CUBE-121 19 247/8 28 173/8
CUBE-131 19 247/8 28 173/8
CUBE-141 22

29 24 193/8

CUBE-161 22

29 24 193/8

CUBE-180 30

353/8 285/8 21

CUBE-200 30

353/8 285/8 21

CUBE-220 34 4225/32 337/8 25


CUBE-240 34 4225/32 337/8 25
CUBE-300 40

50

36

29

CUBE-360 46 5611/16 391/8 293/8


CUBE-420 52 653/16 44 35
CUBE-480 58 743/16 481/8 36

ROOF
DAMPER IN STOCK MIN/MAX SONES
OPENING SIZE^ SIZES ()
RPM
@ 0 IN.
650
8.1
14 x 14

1725
13.8
860
4.6
14 x 14

1820
14.3
12 x 12
685
4.4
14 x 14

1725
15.6
650
6.2
14 x 14
1645
17.9
590
5.0
18 x 18

1725
26
16 x 16
730
8.1
18 x 18

1390
22
630
7.1
20 x 20

1495
28
18 x 18
500
6.2
20 x 20

1210
25
450
7.3
26 x 26
955
25
24 x 24
410
6.4
26 x 26

930
24
355
6.9
32 x 32 30 x 30

905
32
300
6.9
38 x 38 36 x 36
690
30
220
6.5
44 x 44 42 x 42
600
29
180
5.5
50 x 50 48 x 48
490
24

PERFORMANCE IN INCHES WG
0
.25
.5
.75
1
2
445
1180 1017 824
586
732
625
481
1549 1459 1350 1234 1106
809
2037 1923 1816 1710 1571
892
2256 2128 2001 1864 1684
1069
3125 3005 2865 2711 2539
2098 1669
3996 3806 3584 3340 3078
2380 1861
5648 5443 5254 5082 4921 3564
2812 1822
6806 6451 6108 5748 5350
3585 2624
7607 7202 6799 6347 5844
3717 2471
8431 7985 7536 6953 6375
5777 4227
14727 14266 13788 13223 12614 9178
8092 6023
18611 17884 17115 16236 15243
9353 5075
25508 24604 23451 22295 21023
11016
29988 28697 27291 25704 23674

*May be greater depending on motor. All dimensions in inches.


^Dampers should not be used in grease applications.
Dimension A - given is the inside dimensions of the curb cap.
The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing.
Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance
ratings do not include the effects of appurtenances (accessories).
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301.
Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

For complete product information


refer to catalog Series C, or
contact your local representative.
16

FANS

Greenheck Fan Corporation certifies that the CUBE


models shown herein are licensed to bear the
AMCA Seal. The ratings shown are based on tests
and procedures performed in accordance with
AMCA Publication 211 and AMCA Publication 311
and comply with the requirements of the AMCA
Certified Ratings Program.

UL/cUL 705
UL/cUL 762
MH 11745-CUBE

CUBE Performance Data - In Stock


Stock Model CUBE fans include disconnect switch, UL/cUL 762 label and heat baffle.

Order stock products online at


www.greenheck.com/qd

MODEL

CUBE-098-4G-QD
1259-1725 RPM
1/4 HP, 115/60/1 ODP

HP

CUBE-101-LMDG-QD
960-1820 RPM
CUBE-121-3G-QD
1068-1545 RPM
1/3 HP, 115/230/60/1
ODP
CUBE-121-LMDG-QD
685-1545 RPM
CUBE-141-5G-QD
951-1400 RPM
1/2 HP, 115/208-230/60/1
ODP
CUBE-141-7G-QD
1215-1595 RPM
3/4 HP, 115/208-230/60/1
ODP
CUBE-141-LMDG-QD
590-1595 RPM
CUBE-161-7G-QD
935-1265 RPM
3/4 HP,
115/208-230/60/1 ODP
CUBE-161-LMDG-QD
730-1390 RPM

TS

PERFORMANCE IN INCHES WG

SONES @
0 in.

MAX
BHP

.125

.25

793

672

522

.375

.5

.625

.75

1189

1125

1056

861

1350

1293

1234

1106

1398

1315

1224

965

1639

1580

1518

1441

1262

1792

1667

1515

1318

998

2106

2006

1896

1772

1628

1442

2517

2445

2361

2271

2173

2068

1949

1642

2889

2825

2757

2683

2601

2517

2429

2225

1974

1743

1364

2476

2300

2109

1893

1583

2940

2796

2640

2475

2297

1770

3532

3425

3301

3172

3035

2893

2582

3900

3806

3698

3584

3464

3340

3078

2380

2154

1861

1403

1160

3302

9.2

0.006

1330

3786

10.7

0.09

909

804

689

361

1550

4412

13.0

0.14

1060

966

878

644

502

860

2505

4.6

0.04

732

625

481

1205

3509

7.7

0.100

1025

957

873

782

662

1660

4834

12.7

0.26

1413

1364

1313

1251

1820

5300

14.3

0.35

1549

1505

1458

1406

685

2342

4.4

0.029

808

669

845

2889

5.3

0.056

997

885

757

1045

3573

6.5

0.105

1233

1141

1053

944

798

1410

4821

11.1

0.26

1664

1594

1528

1463

1545

5283

12.8

0.34

1824

1760

1698

590

2259

5.0

0.040

1068

851

1105

4230

10.9

0.26

2001

1905

1/3

1210

4632

12.2

0.34

2191

1390

5322

14.9

0.52

1595

6106

20

0.79

730

3177

8.1

0.15

2098

1904

1669

1389

875

3808

11.0

0.26

2515

2361

2177

1/3

965

4200

12.4

0.35

2774

2637

1110

4831

15.0

0.54

3190

3072

1265

5505

18.5

0.79

3636

1390

6049

22

1.05

3995

630

3051

7.1

0.16

CUBE-101-4G-QD
1191-1660 RPM
1/4 HP, 115/60/1 ODP
CUBE-101-3G-QD
1408-1820 RPM
1/3 HP, 115/208-230/60/1
ODP

RPM

1/3

1/3

CUBE-180-LMDG-QD
630-1495 RPM

745

3608

9.2

0.26

2814

2616

2448

2143

1763

1/3

820

3971

11.2

0.34

3097

2915

2759

2525

2257

1866

940

4552

13.8

0.52

3551

3388

3243

3115

2879

2654

2363

1075

5206

16.5

0.78

4061

3919

3786

3666

3554

3344

3141

2652

1185

5739

18.5

1.04

4476

4347

4223

4108

4005

3903

3702

3336

1360

6586

23

1.58

5137

5025

4913

4811

4710

4620

4531

4232

1495

7240

28

2.10

5647

5545

5443

5345

5253

5162

5082

4921

500

2797

6.2

0.15

2812

2386

1821

CUBE-200-LMDG-QD
500-1210 RPM

605

3385

8.1

0.26

3402

3054

2674

2144

1/3

665

3721

9.4

0.35

3740

3421

3095

2699

2072

760

4252

12.1

0.52

4274

3993

3718

3413

3048

2517

875

4896

16.3

0.79

4921

4676

4438

4192

3922

3626

3240

960

5372

18.7

1.04

5399

5175

4957

4742

4508

4253

3985

3168

1100

6155

23

1.57

6187

5991

5798

5610

5420

5216

5006

4528

1210

6771

25

2.09

6805

6628

6450

6279

6108

5932

5747

5349

Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free
field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

18

FANS

CUBE Performance Data - In Stock


Stock Model CUBE fans include disconnect switch, UL/cUL 762 label and heat baffle.

Order stock products online at


www.greenheck.com/qd
MODEL

HP

CUBE-240-LMDG-QD
410-930 RPM

TS

SONES @
0 in.

MAX
BHP

.125

410

2629

6.4

0.18

3716

3169

2471

.75

465

2982

7.6

0.26

4215

3767

3187

2162

1/3

510

3271

8.9

0.34

4623

4242

3716

3134

585

3752

11.5

0.51

5303

4960

4539

4093

3565

670

4297

14.3

0.79

6073

5762

5460

5052

4059

4202

3524

735

4714

16.6

1.04

6663

6370

6133

5764

5409

5037

4618

845

5419

19.6

1.58

7660

7399

7183

6947

6615

6304

6002

5282

930

5965

24

2.10

8431

8194

7985

7798

7536

7233

6953

6375

355

2834

6.9

0.31

5777

5131

4226

1/3

CUBE-300-LMDG-QD
355-905 RPM

PERFORMANCE IN INCHES WG
.25
.375
.5
.625

RPM

365

2914

7.2

0.34

5939

5316

4463

420

3353

9.0

0.52

6834

6314

5659

4820

480

3832

11.0

0.77

7811

7376

6844

6231

5440

530

4231

13.3

1.05

8624

8231

7771

7245

6636

605

4830

17.0

1.56

9845

9500

9127

8705

8226

7707

7083

665

5309

20

2.07

10821

10508

10192

9410

8967

8495

7270

765

6108

24

3.15

12449

12176

11903

11607

11273

10938

10553

9743

905

7226

32

5.19

14727

14496

14266

14036

13788

13505

13203

12614

5879

CUBE-HP Performance Data - In Stock


Stock Model CUBE-HP fans include disconnect switch, UL/cUL 762 label and heat baffle.
MODEL

PERFORMANCE IN INCHES WG

RPM

TS

SONES @
.5 IN.

MAX
BHP

.5

895

3426

6.1

0.055

330

1465

5609

14.2

0.26

1/3

1605

6145

15.2

1845

7064

2110

HP

.75

1.25

1.5

1015

920

797

642

0.34

1146

1062

965

845

703

17.0

0.52

1363

1292

1218

1136

8078

19.8

0.78

1592

1535

1472

795

3850

8.3

0.22

1570

1/3

925

4480

10.8

0.35

2104

1687

1065

5158

13.8

0.53

2581

2323

1932

1215

5884

15.0

0.79

3062

2867

1335

6465

18.7

1.04

3440

1530

7410

24

1.57

1685

8160

27

675

4329

775

1.75

2.25

2.5

1041

923

800

1408

1341

1261 1178 1073

965

2626

2286

1853

3260

3075

2839

2523

2155

4034

3884

3728

3574

3375

3134 2859 2533

2.09

4495

4369

4225

4085

3945

3767 3574 3324 3061

9.4

0.52

3405

2606

4970

13.1

0.78

4232

3704

2940

850

5451

14.5

1.04

4811

4367

3845

3024

975

6253

18.4

1.56

5736

5386

4988

4538

4005

1070

6863

22

2.08

6404

6112

5774

5407

4990

4549 3624

1230

7889

26

3.16

7513

7279

7016

6729

6409

6090 5709 5325 4721

CUBE-141HP-LMDG-QD
895-2110 RPM

CUBE-180HP-LMDG-QD
795-1685 RPM

CUBE-240HP-LMDG-QD
635-1230 RPM

Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include
transmission losses. Performance ratings do not include the effects of appurtenances (accessories).
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field
calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The
AMCA Certified Ratings Seal applies to sone ratings only.

FANS

19

C*

13/4 in.
A

Sidewall Exhaust - CW/CW-HP/CWB/CWB HP


These fans are ideal for exhausting contaminated air out and away from buildings. Fan wheels are centrifugal, backward
inclined, and constructed of aluminum.
Model CW Sidewall Exhaust fans are the centrifugal direct drive type.
Model CWB Sidewall Exhaust fans are the centrifugal belt drive type. Adjustable motor pulleys allow for final system balancing.
B**

Wall Opening

PERFORMANCE

CW performance
capabilities range from
70 cfm to 3,277 cfm and
up to 1.5 in. wg of static
pressure.

5in. *

*Note: 2 inches minimum. 5 inches when motorized damper is required.

CW CONDENSED PERFORMANCE &


DIMENSIONAL DATA
MODEL

B**

WALL
OPENING

CW-060

183/8

13

14

8 x 8

CW-065

183/8

13

14

8 x 8

CW-070

183/8

13

14

8 x 8

CW-075

183/8

13

14

8 x 8

21

133/8

177/8

10 x 10

CW-085

21

133/8

177/8

10 x 10

CW-090

21

133/8

177/8

10 x 10

CW-095

21

15

177/8

10 x 10

CW-098

247/8

28

19

12 x 12

CW-101

247/8

28

19

12 x 12

CW-121

247/8

28

19

12 x 12

CW-131

247/8

28

19

12 x 12

CW-141

287/8

29

221/8

15 x 15

CW-161

287/8

29

221/8

15 x 15

CW-180

353/8

285/8

27

17 x 17

CW-200

353/8

285/8

27

17 x 17

CW-080

CWB performance
capabilities range from
258 cfm to 12,449 cfm
and up to 2.75 in. wg of
static pressure.

Performance for available IN STOCK SIZES is shown on page 25

DAMPER IN STOCK MIN/MAX SONES


SIZE^
SIZES ()
RPM
@ 0 in.
1050
1.7
1550
4.2
1050
2.2

1550
4.7
8x8
1050
2.6

1550
5.5
1050
3.4

1550
6.0
1050
3.8

1550
7.3
1050
4.0

1550
7.5
10 x 10
1050
4.1

1550
7.8
1050
5.3

1550
9.6
860
8.4
1725
13.8
860
4.6

1725
13.3
12 x 12
860
5.3

1725
15.6
860
8.5
1725
18.8
860
7.3

1725
26
15 x 15
860
10.7
1140
15.7
860
12.3
1140
17.6
17 x 17
860
15.7
1140
24

PERFORMANCE
0
.125
.25
133
81
197
164
128
180
109
266
222
172
250
171
369
325
269
287
188
424
359
291
325
247
133
480
431
376
389
305
182
574
520
461
549
451
306
811
744
677
711
570
381
1049 964
861
588
409
1180 1094 1017
732
625
481
1468 1422 1373
1015 905
781
2037 1979 1923
1180 1057 914
2366 2305 2244
1558 1427 1264
3125 3066 3005
2472 2315 2126
3277 3161 3035
3249 3074 2922
4307 4173 4045
4837 4587 4346
6412 6224 6036

IN INCHES WG
.5
.75
1.5

235
312
501
616
824

586

1255 1129
1816 1710 1176
2122 1994
2865
1680
2745
2474
3822
3815
5674

2711 2085
2421
3470
3084
5283 3445

CW HIGH PRESSURE CONDENSED PERFORMANCE &


DIMENSIONAL DATA
IN STOCK SIZES not available for High Pressure
B**

WALL
OPENING

DAMPER
SIZE^

29

221/8

15 x 15

15 x 15

CW-180HP 353/8 285/8 273/4

17 x 17

17 x 17

MODEL

CW-161HP 287/8

MIN/MAX
RPM
1140
1725
1725

SONES
@ .5 in.
12.5
22
28

.5
1645
2787
4613

PERFORMANCE IN INCHES WG
.75
1
1.25 1.5 1.75
2
1444 1175
2680 2560 2439 2310 2167 2003
4493 4353 4215 4078 3914 4340

**May be greater depending on motor. All dimensions in inches.


Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances
(accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA
Standard 301. Values shown are for installation type A: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
^Dampers should not be used in grease applications.

UL/cUL 705
UL/cUL 762 (size 98 and up)
MH11745 - CW/CWB

Greenheck Fan Corporation certifies that the CW


and CWB models shown herein are licensed to
bear the AMCA Seal. The ratings shown are based
on tests and procedures performed in accordance
with AMCA Publication 211 and AMCA Publication
311 and comply with the requirements of the
AMCA Certified Ratings Program.

For complete product information


refer to catalog Series C, or
contact your local representative.
FANS

23

Sidewall Exhaust - CW/CW-HP/CWB/CWB HP

Order stock products online at


www.greenheck.com/qd

CW PERFORMANCE DATA - IN STOCK

Stock Model CW fans include birdscreen, disconnect switch, UL/cUL 705 label.
PERFORMANCE IN INCHES WG

RPM

TS

SONES @
0 in.

MAX
BHP

.125

1050

2234

2.2

.009

180

109

1300

2765

3.2

.017

223

170

97

1550

3297

4.8

.028

266

222

172

1050

2234

2.5

.008

250

172

1300

2765

4.1

.015

309

255

152

1550

3297

5.6

.026

369

325

269

1050

2234

3.3

.012

287

188

1300

2765

4.4

.024

356

279

185

1550

3297

6.1

.039

424

359

291

CW-080-DGEX-QD
1/20 HP
3 Speed

1050

2990

3.8

.016

325

248

133

1300

3701

5.4

.031

403

343

272

173

1550

4413

7.3

.054

480

431

376

315

CW-085-DGEX-QD
1/20 HP
3 Speed

1050

2990

3.6

.018

389

305

182

1300

3701

5.4

.035

482

416

340

235

1550

4413

7.5

.061

574

520

462

395

CW-090-DGEX-QD
1/15 HP
3 Speed

1050

2990

3.8

.027

550

450

306

1300

3701

5.4

.052

680

600

516

391

1550

4413

7.5

.088

811

744

677

CW-095-DGEX-QD
1/8 HP
3 Speed

1050

2990

4.9

.037

711

569

381

1300

3701

7.4

.072

880

773

1550

4413

9.6

.121

1049

1140

3320

7.2

0.09

970

1140

3898

7.4

0.14

1346

1260

1179

1091

980

833

1140

4364

11.3

0.29

2064

1972

1864

1744

1604

1429

MODEL

CW-065-DGEX-QD
1/30 HP
3 Speed

CW-070-DGEX-QD
1/30 HP
3 Speed

CW-075-DGEX-QD
1/25 HP
3 Speed

CW-101-BX-QD
1/6 HP
CW-121-BX-QD
1/6 HP
CW-141-BX-QD
1/4 HP

.25

.375

.5

.625

.75

95

160

204

236

313

161

603

501

347

641

484

200

964

861

746

616

896

806

707

443

1166

Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories).
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are
for installation type A: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

CWB PERFORMANCE DATA - IN STOCK


MODEL

HP

RPM

TS

SONES @ MAX
0 in
BHP

Stock model CWB fans include birdscreen, disconnect switch,


UL/cUL762 and heat baffle.
PERFORMANCE IN INCHES WG
0

.125

590

2259

7.3

0.04

1069

851

1090

4173

10.7

0.25

1975

1877

.25

.375

.5

1763

1633

1476

.75

1.25

1.5

1.75

2085

1704

CWB-141-LMDG-QD
590-1590 RPM

CWB-180-LMDG-QD
545-1480 RPM

1/3

1200

4594

12.1

0.34

2174

2088

1987

1875

1749

1410

1400

5360

15.2

0.53

2537

2465

2382

2292

2196

1974

1675

1590

6087

19.9

0.78

2881

2817

2748

2674

2592

2420

2213

1952

2711

2539

2339

1725

6605

26

1.0

3125

3066

3005

2936

2865

740

3584

9.1

0.25

2795

2596

2422

2115

1723

1/3

830

4019

11.4

0.36

3135

2954

2799

2575

2315

960

4649

14.2

0.55

3626

3466

3323

3197

2981

2487

1070

5182

16.4

0.77

4042

3898

3765

3645

3533

3113

2613

1200

5811

18.8

1.08

4533

4405

4281

4168

4066

3778

3411

2948

1360

6586

22

1.58

5137

5024

4911

4809

4710

4531

4229

3909

1480

7168

26

2.03

5591

5487

5383

5284

5193

5021

4845

4517

Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not
include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field
calculated per AMCA Standard 301. Values shown are for installation type A: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone
ratings only.
FANS

25

Roof Supply Fans - RSF/RSFP


Models RSF and RSFP are roof mounted, filtered supply fans designed to provide efficient and economical make-up air.
Galvanized steel housings are designed for maximum airflow and weather protection.

PERFORMANCE
Performance capabilities
range from 650 to 14,300
cfm and up to 2 in. wg of
static pressure.

BL

CL

RSF

RSFP
A

2 1/2 in.

21/2 in.

RSF STANDARD CONDENSED PERFORMANCE


& DIMENSIONAL DATA
MODEL

RSF-90

RSF-100

RSF-120

RSF-150

RSF-180

RSF-200

A (Sq.)

26

30

34

40

46

52

B (Sq.)

351/8

411/8

471/8

531/8

611/8

731/8

25

25

27

31

34

39

RECOMMENDED
ROOF OPENING

15 x 15

17 x 17

21 x 21

23 x 23

29 x 29

33 x 33

DAMPER
SIZE

12 x 12

14 x 14

18 x 18

20 x 20

26 x 26

30 x 30

CFM

PERFORMANCE IN INCHES WG
.125

.25

650

435

569

1530

707

783

2300

994

1048
505

700

377

2500

796

852

3400

1052

1089

1150

330

430

3220

615

664

4600

844

877

1625

274

363

4730

516

588

6800

708

739

2450

241

317

7220

478

516

10400

665

687

2900

200

266

11260

488

509

14300

609

626

.5

1.5

924

1172

1385

957

1146

1314

1468

760

930

1079

1213

641

784

913

1030

581

691

799

901

553

639

719

794

All dimensions in inches. Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP/kW) does not
include transmission losses. Performance ratings include the effects of 1 in. aluminum filters.

For complete product information


refer to catalog Model RSF & RSFP,
or contact your local representative.
26

FANS

Greenheck Fan Corporation certifies that the RSF/


RSFP models shown herein are licensed to bear
the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
with AMCA Publication 211 and comply with
the requirements of the AMCA Certified Ratings
Program.

UL/cUL 705
E40001 - RSF

Supply Air Fan - SAF

STANDARD CONSTRUCTION FEATURES

OPTIONS AND ACCESSORIES

Heavy gauge galvanized steel housing


Double width, double inlet forward curved wheel
Removable cover allows complete accessibility to blower assembly
1 inch washable aluminum filters, easily removable for cleaning
Vibration isolation for entire blower assembly
AMCA Certified Ratings Seal for Sound and Air Performance
Mounted and wired Nema-1 disconnect switch
Lifting lugs
Energy efficient motor
UL/cUL 705 Electrical

Duct adaptors (In Stock)


Curb adaptors
Gravity and motorized dampers (In stock)
High velocity supply dampers
Galvanized roof curbs (In stock)
Aluminum roof curbs (See pages 114-115)
Curb extensions
Replacement filter sets
Curb seal
Curb adapter/reducer

Order stock products online at


www.greenheck.com/qd
IN STOCK SIZES are galvanized steel construction and include washable
aluminum filters. UL/cUL 705.

SAF PERFORMANCE DATA - IN STOCK


MODEL

SAF-110-LMDX-QD

SAF-112-LMDX-QD

SAF-115-LMDX-QD

SAF-118-LMDX-QD

PRESSURE IN INCHES WG

CFM

OV

MAX
BHP

.125

.25

820

877

0.08

RPM

432

549

1180

1263

0.22

RPM

525

616

780

1540

1658

0.55

RPM

632

707

844

1900

2033

1.02

RPM

745

809

927

1140

2260

2418

1.05

RPM

859

920

1023

1210

.5

1.5

2.5

1127

1082
1328

2620

2803

0.97

RPM

977

1032

1250

1850

0.11

RPM

390

483

1750

2590

0.31

RPM

459

549

682

2250

3330

0.49

RPM

549

615

745

2750

4070

1.04

RPM

647

698

810

990

3250

4810

1.45

RPM

748

790

880

1063

3750

5550

1.5

RPM

849

888

962

1300

2717

0.23

RPM

316

407

546

2000

4180

1.05

RPM

387

463

586

781

2700

5643

1.89

RPM

479

534

642

821

970

3400

7106

1.91

RPM

577

621

712

870

1011

4100

8569

2.04

RPM

677

717

785

935

4800

10032

1.96

RPM

780

815

2500

7400

0.37

RPM

294

359

466

3700

10952

1.67

RPM

376

426

516

664

800

4900

14504

4.46

RPM

466

508

582

713

828

932

1034

6100

18056

4.73

RPM

563

594

661

775

878

973

1059

7300

21608

4.63

RPM

662

688

744

846

939

8500

25160

4.64

RPM

760

786

831

934
1098

Performance certified is for Model SAF exhaust for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance
ratings include the effects of filters in the airstream.
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free eld calculated per AMCA Standard 301. Values shown are for
installation type A: Free inlet fan sone levels.

FANS

29

Make-Up Air Systems - KSFD & KSFB


STAND ALONE - STANDARD WEATHERHOOD
KSFD and KSFB - Arr. Hz

Width

H05

41

15

20

H08

41

15

37

H15

81

23

32

H25

100

30

41

KSFD and KSFB - Arr. DB

DB

Housing Size

Hz.

Housing Size

Width

H05

32

19

20

H08

32

19

37

H15

72

26

32

H25

82

34

41

All dimensions are in inches.

STAND ALONE - EXTENDED WEATHERHOOD


KSFD and KSFB - Arr. DB

Housing Size

Width

H05

172

15

20

H08

166

15

37

H15

146

23

32

H25

153

30

41

All dimensions are in inches.

3 FT. VERTICAL SEPARATION COMBINATION PACKAGE - STANDARD WEATHERHOOD


A
KSFD and KSFB - Arr. DB3

3 ft.
min.

Housing Size

A*

B*

Width*

H05

71

50

25

H08

83

53

36

H15

132

55

43

H25

165

67

59

All dimensions are in inches.


*Maximum dimensions (dependent on
CUBE fan).
Dimensions are in inches and include mixing box and
standard weatherhood. For roof opening dimensions and
locations refer to factory submittal.

10 FT. HORIZONTAL SEPARATION COMBINATION PACKAGE - EXTENDED WEATHERHOOD


A

B
KSFD and KSFB - Arr. DBC

10 ft.
min.

Consult your representative for dimensional data when the evaporative


cooling option is selected.

Housing Size

A*

B*

Width*

H05

201

50

25

H08

208

53

36

H15

197

55

43

H25

218

67

59

All dimensions are in inches.


*Maximum dimensions (dependent on CUBE
fan).

FANS

31

Ceiling Exhaust - SP
B

D
E

SP-C50

E
C

SP-A110 through SP-A510


and SP-A710 & SP-A780

SP-B50 through SP-B200

OUTLET
D
E

SP-C50-QD

35/8

SP-B50-QD

137/8

11

615/16

4 dia. x

SP-B70-QD

137/8 11

615/16

4 dia. x

SP-B80-QD

137/8

615/16

4 dia. x

SP-B90-QD

137/8 11

715/16 6 dia. x 1

SP-B110-QD

137/8 111/2

715/16 6 dia. x 1

SP-B150-QD

137/8

715/16

SP-B200-QD

137/8 111/2

SP-A50-QD

137/8 105/8 115/8

6 dia. x 1

SP-A70-QD

137/8

115/8

SP-A90-QD

137/8 105/8 115/8

SP-A110-QD

13

105/8

10

SP-A125-QD

13 105/8 10

SP-A190-QD

13 105/8 10

SP-A200-QD

137/8

65/8

SP-A250-QD

14

117/8 11

SP-A290-QD

14

SP-A390-QD
SP-A410-QD

RPM AMPS WATTS

3 dia. x 15/8 1680

SONES
GRILLE SIZE
@ 0 IN.

SP-A700, SP-A900
& SP-A1550

Order stock products online at


www.greenheck.com/qd

SP PERFORMANCE & DIMENSIONAL DATA - IN STOCK


MODEL

0.00

PERFORMANCE IN INCHES WG
.100 .125 .250 .375 .500 .625 .750 1.00

0.80

46

2.9

9 x 9

52

49

48

46

43

625

0.50

38

1.7

14 x 12

67

53

51

40

29

675

0.53

45

1.7

14 x 12

77

70

68

57

49

39

900

0.60

54

2.9

14 x 12

87

80

78

68

61

54

44

700

0.65

50

1.9

14 x 12

102

92

88

75

59

45

30

950

1.14

80

2.0

14 x 12

133

114

110

97

95

94

91

85

6 dia. x 1 1050

1.70

129

3.0

14 x 12

160

156

155

154

152

149

147

138

92

715/16 6 dia. x 1 1100

2.20

173

4.4

14 x 12

197

195

194

191

187

184

181

166

128

700

0.31

18

0.7

14 x 12

76

51

47

30

6 dia. x 1

850

0.27

20

1.1

14 x 12

83

70

66

42

6 dia. x 1

900

0.34

29

1.1

14 x 12

99

88

84

61

950

0.58

49

1.3

14 x 12

119

110

106

88

1100

0.62

53

1.4

14 x 12

135

123

121

104

1400

1.30

113

3.2

14 x 12

216

197

192

167

133

900

0.43

48

2.0

14 x 12

247

225

220

196

172

142

105

67

1000

0.77

83

2.9

14 x 12

272

251

246

227

210

185

157

119

117/8 11

1050

0.72

81

3.2

14 x 12

315

293

287

257

231

207

175

124

14

117/8

11

1350

1.34

135

5.4

14 x 12

410

395

391

368

345

325

307

279

18

143/8 14

1000

1.74

121

4.1

193/8 x 163/8

443

413

405

351

305

SP-A510-QD

18

143/8 14

1070

3.30

224

6.1

193/8 x 163/8

557

512

501

439

392

325

SP-A700-QD

137/8

111/2

115/8

191/2

1100

3.20

350

1.9

251/8 x 131/2

757

729

723

700

679

649

613

560

SP-A710-QD

18

143/8

14

10

1080

4.40

285

7.4

193/8 x 163/8

752

714

701

653

588

485

320

SP-A780-QD

18

143/8

14

10

1600

3.30

348

10.2

193/8 x 163/8

812

782

775

741

704

665

625

23 143/8

14

18

950

4.00

285

5.2

25 x 163/8

955

907

896

841

773

701

SP-A1050-QD 23 143/8

14

18

1095

6.30

420

7.2

25 x 163/8

1125 1059 1043 964

885

796

163/8

1455 1414 1404 1353 1307 1262 1218 1174


1607 1568 1558 1506 1449 1407 1369 1323

SP-A900-QD

11

11

1/2

105/8

11

143/8

14

18

1450

7.40

786

11.6

25 x

SP-A1550-QD 23 143/8

14

18

1610

8.60

818

12.4

25 x 163/8

SP-A1410-QD 23

37

29

30

50

25

396

581

662

All dimensions in inches.


Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed
(RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical
free field calculated per AMCA Standard 301. Values are for installation type B: free inlet sone levels. The AMCA Certified Ratings Sound Seal applies to sone
ratings only.

UL/cUL 507
E33599
Ceiling Exhaust Fans are also UL Listed
for sizes 50 through 390 for above
bathtub/shower with GFCI branch
protected circuit. File No. E33599

Greenheck Fan Corporation certifies that


the SP models shown herein are licensed to
bear the AMCA Seal. The ratings shown are
based on tests and procedures performed in
accordance with AMCA Publication 211 and
AMCA Publication 311 and comply with the
requirements of the AMCA Certified Ratings
Program.

For complete product information


refer to catalog Model SP and
CSP, or contact your local
representative.
FANS

33

G
E

D
A

D
dia.
Inlet
F xG
C

B
A

Roof Discharge Accessories


D

11 /8
1

RJ-4 & RJ-6 x 9

91/4

31 /2

10

MODEL RJ
Pitched Roof Cap

11 1
/2

B
A

Steel construction with black enamel finish


Integral flashing flange
Built in birdscreen and damper

5 /8
1

RJ-10 x 10

MODEL

FOR USE
WITH SIZES

THROAT

RJ-4

C50, B50-B80

11

5 5/16

4 in. Dia.

RJ-6 x 9

B90-B200
A50-A390

18

14

14

10 3/8

6x9

RJ-10 x 10

A410-A1050

18

27

15

235/8

10 x 10

MODEL EL - 10x3
Elbow Discharge with Grille

Designed for installation under roof eaves


Painted steel louvered grille
Built in damper
For SP/CSP sizes 50-290

All dimensions in inches.

Flat Roof Caps


CURB CAP

FLASHING FLANGE
B

FOR USE
WITH SIZES

Dia.
A

MODEL RFC-7

All aluminum exterior


construction
Galvanized steel
internal supports
Integral birdscreen
Built in curb cap
Requires roof curb

Weathertight aluminum
construction
Integral birdscreen
Built in curb cap
Requires roof curb

MODEL

13/4 in.

MODEL GRS

MODEL RCC-7

Dia.
Dia.
A

11/2 in.

Dia.

MODEL GRSF

Weathertight
aluminum construction
Integral birdscreen
Built in flashing flange

MODEL

Dia.

FOR USE
WITH SIZES

All aluminum exterior


construction
Galvanized steel internal
supports
Integral birdscreen
Built in flashing flange

Dia.
7
10

RCC-7

50-390

15

12

10

63/8

RFC-7

50-390

18

12

10

63/8

GRS-10

410-710

19

20

10

GRSF-10

410-710

23

20

GRS-12

780-1050

22

24

77/8

12

GRSF-12

780-1050

26

24

77/8

12

165/16

205/16

GRS-16

1410-2150

26

285/8

165/16

GRS-20

3600

30

35

205/16

GRSF-16

1410-2150

30

285/8

GRSF-20

3600

34

35

All dimensions in inches.

All dimensions in inches.

HANGING VIBRATION ISOLATORS


Vibration isolator kits are available
for suspended installations. Kits
include all hardware necessary to
mount one unit, with the exception
of 10-32 threaded rod to be supplied
by others. Fan mounting brackets
include prepunched mounting holes
for ease of installation.

UNIT SIZE

B50-B200

155/8

A50-A190

145/8

A200-A390

15

A410, A510
A710, A780

195/8

A700

251/8

A900-A1050
A1410-A1550

253/8

A1750, A2150

36

A3600

485/8

All dimensions in inches.

10-32 hanging
support rod
by others

FANS

37

Wall Discharge Accessories


MODEL WC

MODEL WC

(Round Connection)
Hooded Wall Cap
Aluminum construction aluminum finish
For outside wall
applications
Built in birdscreen (not
available on WC-4)
and damper
FOR USE
WITH SIZES

MODEL

C50, B50-B80
B90-B200
A50-A190
A200-A510

WC-4
WC-6
WC-8

8.5

41/8

8.5

11

11

51/8

8.5

FOR USE
WITH SIZES

MODEL

C
A

WC-10 x 3

50-290

12

10

WC-8 x 8

200-510

10

10

WC-18 x 8

700-1550

10

20

18

18

FOR USE
WITH SIZES

Brick Vent
Designed for installation in
masonry walls
Anodized aluminum
construction
Built in aluminum mesh insect
screen

MODEL

FOR USE
WITH SIZES

50-290

8 1/8

BVE808

WL-10 x 3

50-290

12

10

BVE128

390-510

12

WL-18 x 6

390-1550

19

18

BVE157

700-1050

15 5/8

All dimensions in inches.

All dimensions in inches.

MODEL RDC Round Duct Connector

ACCESSORY PRESSURE DROPS

The chart below can be used with all of the discharge


accessories shown on these two pages. Specific pressure
drop values for these accessories must be included in
total system calculations for proper fan selection.
30

20
WL-18x6

Replaces the standard


square discharge ductconnector and damper.
Uses existing mounting
holes
Galvanized steel
construction
RDC 6 includes a damper
RDC 8 does not include a
damper

RJ-10x10

MODEL

FOR USE
WITH SIZES

DIA.

RDC-6

A110-A190

RDC-8

A200-A510

10

CFM x 100

111/8

MODEL BVE
B

Anodized
E
aluminum grille
Built in damper
D
Not recommended
A
for exterior
applications
exposed to severe
weather conditions. An external wall louver is
recommended for such applications.

BVE-157
WC-18x8

9
8
7

BVE-128
WC-8x8
WC-8

WC-10x3
WC-6
RJ-6x9
EL-10x3
WL-10x3
BVE-808
RFC-7
RCC-7

5
4

All dimensions in inches.

MODEL TR 6x4
Transition Duct Reducer
Reduces duct from 6 to 4 inches.
Galvanized steel construction
MODEL

.03

.04 .05 .06 .07 .08 .09.10

.2

.3

.4

.5

Pressure Drop in Inches of Water Gauge

Above accessories tested with 4 feet of inlet duct

FOR USE
WITH SIZES
B50-B200

.6

TR 6 x 4

A50-A90
A110-A190*

38

Wall Louvered
Discharge

.02

All dimensions in inches.

MODEL WL

.01
1

Steel construction with


black enamel finish
For outside wall
applications
Built in birdscreen and
damper

All dimensions in inches.

MODEL

(Square/Rectangular
Connections)
Hooded Wall Cap

FANS

*Used in conjunction with RDC-6.


All dimensions in inches.

RDC-6

RDC-8

Accessories
MOTION DETECTORS
Motion detectors may be used with Models SP and CSP fans, or fan and light combinations. Motion
detectors use a passive infrared motion detector that will automatically turn on the fan when a change
in temperature is sensed. They have a viewing area of 180 degrees, however they must be placed in
the line-of-sight. They also have an adjustable time
delay shutoff setting of 1 to 20 minutes.
HOT

BLACK

Model MDW - For use on fan or lights. Available


shipped loose.
Rated for 115V
UL/cUL Listed
Requires 2 x 4 handy box

GREEN
GND.
RED
LOAD

NEUTRAL

(12.5 AMPS MAX)

TRANSFORMERS
Transformers are available for applications requiring voltage
reduction. Selection is based on motor amperage. All transformers are
shipped loose.
277 V SUPPLY
SWITCH BOX

Model T-2.0 - UL/cUL Listed


Rated for 230/277 to 115, 2 Amps

BLK BLK BLK

H1

Model T-4.3 - UL/cUL Listed


Rated for 230/277 to 115, 4.3 Amps

H2

H3

277V TO 115V TRANS.


750 VA

X1

X2

SWITCH

RED RED

Model T-6.5 - UL/cUL Listed


Rated for 230/277 to 115, 6.5 Amps
Model T-8.6 - UL/cUL Listed
Rated for 230/277 to 115, 8.6 Amps

115 V MOTOR

CEILING RADIATION DAMPERS


The Greenheck SP-A and SP-B ceiling
radiation dampers are UL/cUL Classified,
rated at three to four hours fire resistance,
and are available on all SP-A and SP-B fans
and fan/light combinations. This design saves
space by allowing the dampers to be mounted
directly beneath the fan.

SP MODEL

CRD

LENGTH

WIDTH

HEIGHT

A50 - A190

310

13.38

11.13

B50 - B200
A200 - A390

320

14.38

12.25

A410 - A510
A710 - A780

350

18.44

14.81

A-700

700

24.19

12.31

A900 - A1550

360

24.19

14.81

All dimensions in inches.

FILTERS

SP MODEL

DESIGNER
GRILLE

FILTER
MODEL

FILTER
AREA (FT2)

SP-A50 - A190

F-200

F-210

.620

SP-B50 - B200, A200 - A390

F-200

F-220

.785

SP-A410 - A510
SP-A710 - A780

NA

F-250

1.319

SP-A900 - A1550

NA

F-260

1.797

Mesh
Filter

FILTER LOSS CHART


.24
.22
.20
.18
.16
Resistance in w.c.

Fans used in most applications, even where air is not excessively dirty, will collect
airborne dirt on wheels and motors over time. Accumulations of dirt on the fan
wheel will sharply reduce performance and cause imbalance. Dirt buildup on the
motor can cause it to overheat. All of these conditions will shorten the life of the fan.
To help reduce this accumulation, washable aluminum mesh filters are available
to trap dirt before it enters the fan. These filters should be regularly cleaned to
maintain performance. Fig. A (Filter Loss Chart) shows the effect the filter will have
on performance. To determine the added resistance, divide the desired cfm by the
filter area (ft2). This will give FPM. Use this with the filter loss chart to get the added
resistance.
In addition to reducing dirt accumulations on the motor
and wheel, filters also reduce sound levels.

.14
.12
.10
.08
.06
.04

SP
Grille

.02

FIG. A
.00

3
4
5
6
Velocity FPM x 100

FANS

39

INLET
OPENING

2 in.

H
W
DAMPER
OUTLET
OPENING

1 in.

F C

1 in.
E
B

Inline Direct Drive and Belt Drive - SQ/BSQ


Models SQ and BSQ are the ideal selection for clean air applications (intake, exhaust, return, or make-up air systems) where
space is a prime consideration. Fan wheels are centrifugal, backward inclined, and constructed of aluminum.
Model SQ Centrifugal Inline fans are direct drive. Maximum operating temperature is 130 F
Model BSQ Centrifugal Inline fans are belt drive. Maximum operating temperature is 180 F.

SQ

PERFORMANCE
1 in.

1 in.

B sq.

SQ performance
capabilities range from
80 cfm to 5,025 cfm and
up to 1.75 in. wg of static
pressure.

B sq.
C sq.

C sq.

BSQ performance
capabilities range from
62 cfm to 26,600 cfm and
up to 3.5 in. wg of static
pressure.

BSQ
A

B sq.
C sq.

C sq.

D*

* May vary depending on motor size.

SQ STANDARD CONDENSED
PERFORMANCE RANGES &
DIMENSIONAL DATA
DAMPER
SIZE

Performance for available IN STOCK SIZES is shown on page 44

IN STOCK
SIZES ()

MODEL

SQ-60

13

12

87/8

SQ-65

13

12

87/8

SQ-70

13

12

87/8

SQ-75

13

12

87/8

SQ-80

16

15

117/8

SQ-85

16

15

117/8

SQ-90

16

15

117/8

SQ-95

16

15

117/8

SQ-100

21

17

137/8

14 x 14

SQ-120

21

19

157/8

16 x 16

SQ-130

21

21

177/8

18 x 18

SQ-140

22

23

197/8

20 x 20

SQ-160

26

26

227/8

23 x 23

9x9

12 x 12

PERFORMANCE IN INCHES WG

MIN/MAX
RPM

SONES
@ 0 in.

.125

.25

1050
1550
1050
1550
1050
1550
1050
1550
1050
1550
1050
1550
1050
1550
1050
1550
860
1725
860
1725
860
1725
860
1725
860
1725

1.7
4.0
2.1
4.2
2.7
5.6
3.6
6.1
3.8
7.3
4.0
7.6
4.0
7.6
4.9
9.6
4.8
13.1
4.5
14.7
6.3
17.4
7.1
20
8.9
26

126
186
154
228
212
313
241
356
306
451
357
528
500
738
623
919
725
1454
971
1948
1180
2368
1637
3283
2506
5027

145
79
184
118
252
146
294
225
394
272
474
369
654
475
829
611
1402
843
1883
1048
2307
1487
3211
2334
4941

105

.5

.75

1.25

1.75

1227

1077

830

1692

1562

1416

1239

2105

1961

1791

1559

2985
1605
4683

2825

2645

2424

1624

4504

4312

4094

3575

128
189
229
104
342
142
413
188
564
274
720
410
1349
704
1818
890
2247
1316
3139
2147
4856

201
254
334
461

All dimensions in inches.


Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings
shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type B:
free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

For complete product information


refer to catalog Models SQ
and BSQ or contact your local
representative.
42

FANS

Greenheck Fan Corporation certifies that the SQ,


BSQ models shown herein are licensed to bear
the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
with AMCA Publication 211 and AMCA Publication
311 and comply with the requirements of the
AMCA Certified Ratings Program.

UL/cUL 705
E40001 - SQ/BSQ

Inline Direct Drive and Belt Drive - SQ/BSQ

SQ PERFORMANCE DATA - IN STOCK


Order stock products online at
www.greenheck.com/qd

Stock Model SQ fans include disconnect switch.


Sizes 100 and above also include a motor cover and UL/cUL 705.
PERFORMANCE IN INCHES WG
.375
.5
.625
.75

HP

RPM

TS

SONES @
0 IN.

MAX
BHP

.125

1/90

1050

2233

3.6

0.011

241

146

1/45

1300

2765

4.1

0.210

298

224

133

1/25

1550

3297

6.1

0.035

356

294

229

1/50

1050

2989

3.8

0.016

306

225

104

1/30

1300

3701

5.4

0.032

378

312

244

140

1/15

1550

4412

7.3

0.055

451

394

342

280

1/140

1050

2989

4.0

0.017

357

272

142

1/30

1300

3701

5.5

0.033

442

377

298

185

1/15

1550

4412

7.6

0.057

528

474

413

343

1/50

1050

2989

4.0

0.020

500

369

188

1/25

1300

3701

5.4

0.040

619

519

397

245

1/10

1550

4412

7.6

0.068

738

654

564

457

1/30

1050

2989

4.9

0.031

623

475

274

1/15

1300

3701

7.6

0.059

771

659

522

352

1/8

1550

4412

9.6

0.100

919

829

720

603

461

276

SQ-100-AX-QD

1725

5052

13.1

0.25

1455

1403

1350

1292

1227

1156

1078

831

SQ-120-AX-QD

1725

5927

14.7

0.48

1948

1884

1819

1754

1692

1625

1563

1417

SQ-140-BX-QD

1/3

1140

4346

10.8

0.30

2107

2061

1942

1818

1666

1447

1121

MODEL

SQ-75-DGEX-QD
3-Speed

SQ-80-DGEX-QD
3-Speed

SQ-85-DGEX-QD
3-Speed

SQ-90-DGEX-QD
3-Speed

SQ-95-DGEX-QD
3-Speed

.25

1.25

137

201

254

334

1240

Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP/kW) does not include transmission losses. Performance ratings do not include
the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA
Standard 301. Values shown are for installation type B: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

SQ & BSQ OPTIONS AND ACCESSORIES


Hanging
Vibration
Isolator Model HVI
(Hanger rods
supplied
by others)

Backdraft Damper
Model WD-330

Housing
Insulation
Kit

Side Discharge
The side discharge option provides several
advantages, from removing a system effect
problem, increasing performance, or even
reducing installation labor.
The most notable is reducing system
effects. Notice Fig. 1 how the air, when
discharged into the corner, will take
several duct lengths before becoming
smooth again. This is not the case with a
side disharge. Notice now in Fig. 2 as air
comes into the fan/corner and leaves the
fan/corner you have nice smooth airow
providing a more predictable system.
(Remember the duct length prior to or
following the installation location should be
approximately two to three wheel diameters
to achieve catalog performance).
Fan

Base Vibration Isolator


Model BVI

Fig. 2

Fan

44

FANS

Fig. 1

Inline Direct Drive and Belt Drive - SQ/BSQ


BSQ PERFORMANCE DATA - IN STOCK

Order stock products online at


www.greenheck.com/qd

Stock Model BSQ fans include disconnect switch, motor cover UL/cUL 705.

MODEL
BSQ-70-4X-QD
1368-1970 RPM
1/4 HP, 115/60/1 ODP

HP

BSQ-80-4X-QD
1222-1835 RPM
1/4 HP, 115/60/1, ODP

1/3

BSQ-80-LMDX-QD
1050-2485 RPM

BSQ-90-4X-QD
1168-1690 RPM
1/4 HP, 115/60/1 ODP

1/3

BSQ-90-LMDX-QD
1050-2690 RPM

1
BSQ-100-4X-QD
1073-1610 RPM
1/4 HP, 115/60/1 ODP

1/3

BSQ-100-LMDX-QD
1050-2555 RPM

1
BSQ-120-4X-QD
923-1370 RPM
1/4 HP, 115/60/1 ODP
BSQ-120-LMDX-QD
1000-2490 RPM

1/3

1
1

BSQ-130-LMDX-QD
900-2355 RPM

1/3

1
1

1/3

BSQ-140-LMDX-QD
800-2135 RPM

1
1
2

1/3

BSQ-160-LMDX-QD
650-2000 RPM

1
1
2
3
1/3

BSQ-180-LMDX-QD
700-1645 RPM

1
1
2
3

BSQ-240-LMDX-QD
500-1225 RPM

1
1
2
3
5

1370
1730
1970
1050
1835
1885
2100

SONES @
0 IN.
11.8
16.1
19.1
8.0
17.2
17.7
21

MAX
BHP
0.088
0.18
0.26
0.049
0.26
0.28
0.39

.125
265
349
404
372
721
742
834

.25
227
323
383
298
688
710
805

.375
186
293
358
184
651
675
775

2645

28

0.79

1065

1041

1018

1050
1360
1695
1750
1910
2220
2690
1050
1265
1610
1765
2030
2325
2555
1000
1370
1500
1725
1974
2170
2490
900
1293
1424
1630
1866
2053
2355
800
1075
1180
1355
1550
1710
1960
2135
650
860
960
1100
1265
1390
1590
1750
2000
700
790
905
1035
1140
1310
1440
1645
500
570
650
715
820
900
1035
1225

8.0
11.7
16.0
16.5
18.1
22
28
7.9
9.8
15.0
16.3
19.7
23
26
7.7
11.0
12.4
15.2
19.7
23
31
7.7
11.9
13.7
16.2
21
25
35
6.3
10.7
12.0
14.2
16.2
18.3
24
30
6.6
8.7
9.8
12.3
15.6
18.0
22
28
40
10.0
10.6
12.2
14.5
16.5
20
23
29
10.7
12.3
14.3
16.1
19.4
22
28
41

0.061
0.14
0.26
0.29
0.37
0.59
1.05
0.073
0.13
0.26
0.34
0.52
0.79
1.05
0.102
0.26
0.34
0.52
0.785
1.05
1.57
0.087
0.26
0.35
0.52
0.78
1.05
1.58
0.11
0.26
0.35
0.52
0.78
1.05
1.58
2.04
0.11
0.25
0.35
0.52
0.79
1.05
1.57
2.08
3.07
0.24
0.35
0.52
0.78
1.04
1.58
2.07
3.14
0.35
0.53
0.78
1.04
1.56
2.07
3.15
5.22

547
753
966
1000
1100
1291
1578
774
966
1266
1398
1623
1872
2065
1026
1475
1629
1893
2183
2410
2779
1084
1652
1838
2126
2448
2702
3112
1362
1925
2132
2474
2852
3161
3640
3975
1671
2333
2637
3058
3550
3920
4509
4979
5710
2649
3046
3546
4101
4545
5259
5803
6656
4518
5279
6121
6795
7874
8689
10058
11973

443
684
915
951
1057
1255
1548
671
893
1207
1345
1577
1832
2028
914
1396
1557
1831
2129
2361
2737
911
1563
1754
2050
2389
2655
3074
1185
1808
2029
2390
2781
3096
3584
3923
1391
2165
2497
2941
3448
3827
4428
4905
5645
2387
2840
3366
3947
4408
5145
5699
6566
4001
4845
5757
6476
7616
8457
9856
11802

290
605
859
898
1009
1216
1519
498
798
1149
1292
1531
1791
1991
783
1315
1484
1768
2075
2312
2694
635
1462
1672
1983
2324
2592
3026
860
1679
1916
2295
2702
3030
3528
3872

RPM

1966
2331
2808
3346
3734
4347
4831
5581
2023
2569
3167
3789
4265
5021
5590
6475
3325
4363
5360
6133
7317
8198
9653
11631

PERFORMANCE IN INCHES WG
.5
.625
.75
1
140
90
260
227
192
112
330
301
272
211

1.25

1.5

1.75

141

614
640
743

571
598
711

525
555
674

426
459
595

297
508

367

995

970

945

894

835

773

705

509
798
841
958
1175
1487

383
730
776
904
1132
1453

655
708
845
1086
1419

439
528
705
987
1347

517
879
1270

733
1185

540
1097

683
1089
1240
1484
1750
1954

1004
1179
1439
1710
1917

917
1101
1396
1669
1880

924
1263
1593
1809

1120
1474
1732

1360
1624

1201
1521

1230
1410
1705
2020
2262
2651

1136
1331
1641
1964
2212
2607

1026
1243
1572
1908
2161
2563

1010
1425
1791
2059
2475

1243
1663
1951
2387

1518
1833
2294

1307
1709
2198

1328
1568
1908
2266
2357
2971

1170
1443
1820
2202
2484
2923

958
1299
1714
2128
2426
2877

1468
1949
2286
2777

1121
1740
2117
2659

1462
1926
2514

1686
2359

1535
1795
2195
2619
2955
3469
3821

1307
1651
2092
2532
2880
3404
3763

1442
1977
2442
2800
3338
3703

1631
2246
2638
3201
3583

1955
2453
3059
3454

1429
2181
2904
3324

1758
2718
3181

1691
2142
2662
3226
3638
4266
4757
5516

1883
2500
3101
3525
4184
4683
5451

2296
2961
3412
4086
4610
5387

2629
3157
3887
4431
5256

2101
2830
3664
4247
5100

2334
3397
4044
4943

3065
3810
4770

2210
2928
3606
4122
4896
5476
6377

1499
2621
3398
3944
4772
5363
6278

2175
3166
3755
4630
5250
6179

2411
3283
4302
4979
5981

2510
3911
4678
5744

3365
4318
5485

3838
5216

3704
4933
5757
7016
7926
9420
11460

4375
5358
6688
7646
9184
11270

4847
6349
7347
8947
11070

5494
6713
8433
10671

5833
7894
10245

7234
9804

6302
9345

Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP/kW) does not include transmission losses. Performance ratings do not include the
effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301.
Values shown are for installation type B: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
FANS

45

Inline Fans Options & Accessories - BDF, BCF, SQ & BSQ


HORIZONTAL MOUNTING
For ease of installation knockouts are provided at each location where mounting
brackets are shown in diagram below. Universally adjustable brackets are available
to mount the fan in hanging or base mounted positions.

HANGING ISOLATORS - Complete hanging isolator kits


are available with either neoprene or spring isolators. The
isolators are sized to match the weight of the fan. (Hanging
rods supplied by others).

ss
ce l
c
A ne
Pa

HANGING NEOPRENE

BASE ISOLATORS - Complete base isolator kits are


available with either neoprene or spring isolators and are sized
to match the weight of the fan.

HANGING SPRING

STANDING NEOPRENE

STANDING SPRING

MULTI DISCHARGE POSITIONS


BDF fans have been designed for horizontal mounting and are standard with a
Bottom Horizontal Discharge. Optional Top Horizontal Discharge is also available.
BCF fans are available with either Top Horizontal or Upblast Discharge positions. SQ
and BSQ fans are available with Right Side Discharge, Left Side Discharge, Inline
Discharge positions, or a combination of Right, Left, and Inline positions.
BDF Discharge Positions
Bottom Horizontal Top Horizontal

Right Side

46

Left Side

FANS

BCF Discharge Positions


Top Horizontal
Upblast

SQ/BSQ Discharge Positions


Inline

Combination

Inline Fans Options & Accessories - BDF, BCF, SQ & BSQ


FILTER BOX
Filter boxes incorporate a vee bank design constructed of galvanized steel. Filters
are available in 1 in. or 2 in. throwaway (pleated) or permanent (washable aluminum
mesh). Side access panels are standard for easy maintenance.

K*

2 in.
n
Facess
l
c
A ane
P

x
Bo
teress
l
i
F cc l
A ane
P

BCF
MODEL
SINGLE DOUBLE
FAN
FAN

BSQ

MODEL
60-75
80-95
100
120
130
140
160

SQ
FILTER
K*
SIZE
221/8
10 x 12
14 x 25
455/8
47
16 x 20
523/16
16 x 25
463/8
20 x 20
523/8
20 x 25
20 x 20
513/8

NO.
FILTERS
1
1
2
2
2
2
4

MODEL

K*

70 - 80 - 90
100
120
130 - 130HP
140 - 140HP
160 - 160HP
180 - 180HP

505/8
47
523/16
463/8
523/8
513/8
551/16

200 - 200HP

6611/16

240 - 240HP

687/8

300 - 300HP

721/8

360 - 360HP
420

79
931/8

FILTER
NO.
SIZE
FILTERS
14 x 25
1
16 x 20
2
16 x 25
2
20 x 20
2
20 x 25
2
20 x 20
2
20 x 25
4
12 x 25
3
16 x 25
3
20 x 25
4
16 x 25
4
20 x 25
8
16 x 25
10
20 x 25
5
16 x 25
5
20 x 25
10

106
107
108
110
112

206
207
208
210
212

FILTER SIZE
K*
44
52
56
61
65

NO. FILTERS

SINGLE DOUBLE SINGLE DOUBLE


FAN
FAN
FAN
FAN

16x20
16x20
16x20
20x20
16x20

20x20
16x20
16x20
20x20
20x25

1
1
2
2
4

1
2
4
4
4

BDF
MODEL

K*

FILTER
SIZE

NO.
FILTERS

80

49

16 x 20

90

547/8

20 x 25

100

517/8

20 x 20

120

639/16

12 x 25

150

621/16

16 x 20

180

753/8

20 x 25

200

85

16 x 25

12

K* is length of fan and filter box combined.


All dimensions in inches.

INSULATED HOUSINGS
The interior of the fan housings and filter boxes can be lined with a fiberglass duct
liner for noise reduction and condensation control. The duct liner can be utilized to
reduce radiated noise from inline fan housings. It is recommended for applications
when fans are placed in acoustically sensitive locations. The duct liner also reduces
the noise radiating from the inlet and outlet of the fan.

FANS

47

D
Max. W/Motor Cover

B
H
C

Motor Positions for Horizontal Fans


(Discharge Views)
A
A
H

F
Base Mount Units

Ceiling Hung Units

Airflow

Airflow

Airflow

Airflow

UBFM

UBCH

DBFM

DBCH

Optional Discharge and Mounting


Bracket Locations for Vertical Fans

Mixed Flow - QEI


The QEI mixed flow fan is a low sound, highly efficient alternative for inline ventilation. The unique half-axial, half-centrifugal
wheel design captures the highly efficient straight-through airflow of vane axials and the lower sound levels of tubular
centrifugal fans to provide an energy efficient product that wont be a noise distraction in your ventilation system.

Axial

Flexible Universal Mounting


System allows for field rotation of
motor location.

Centrifugal

Mixed Flow

All motors are mounted on


adjustable pivot bases for
easy adjustments.

Sealed belt guard protects


personnel and minimizes air
leakage around motor shaft.

Extended collar on
inlet and outlet allow
for quick and easy slipfit duct connections to
ductwork or plenum wall.
Flexible Sleeve

Permatector coating
is an industrial grade,
electrostatic powder
paint. Provides a
durable, long lasting
finish for interior or
exterior applications.

Fan

Cast flange mounted


bearings are air-handling
quality and use concentric
bore locking systems for
smooth operation. Bearings
are selected for a minimum
L(10) life in excess of 80,000
hours at the maximum fan
class RPM. {Average life L(50) of 400,000 hours}

Integral, spun inlet cone


provides even airflow into the
wheel in ducted or
non-ducted applications
and helps to reduce system
effects associated with uneven
duct velocity profiles.
Mixed flow wheels are designed with
single-thickness, cambered blades
to maximize free area and efficiency.
Tight wheel to cone tolerances
further improve the mechanical
efficiency.

LOWER SOUND POWER,


BETTER SOUND QUALITY

Aerodynamically designed
straightening vanes improve
performance by converting
kinetic energy of swirling air
into useful static pressure.

100

Sound Power, dB

The sound quality of the QEI is as beneficial to low sound


design as is the reduced overall sound power. The sound
chart compares units of similar outer tube diameters at an
operating point of 20,000 cfm with 1.5 inches wg of static
pressure (Ps). Tubular centrifugals (green) have dominant
tones in the 63 hz through 250 hz octave bands, while
vane axials (red) have more mid to high frequency sound.
The QEI does not have a dominant tone. A bystander
would hear a more bland sound that is quieter than a
tubular centrifugal or vane axial.

90

80

70

60
62

125

250

500

1000

Frequency, Hz
QEI

50

FANS

Duct

Typical Vane Axial


Typical Centrifugal

2000

4000

8000

Optional
Mounting Rails

Horizontal Base Mount

Fig. 1

Horizontal Base Mount


Motor at 3 (C) or 9 Oclock (G) Position

Fig. 2

Optional
Mounting Rails

Horizontal Ceiling Hung


Motor at 3 (C) or 9 Oclock (G) Position
Horizontal Ceiling Hung

Fig. 4

Fig. 3

A
H

B
C

C
D

F
E

Tube Axial TDI/TBI-CA/TBI-FS

Model TDI direct drive tube axial fans


are best suited for applications moving
relatively clean, dry and cool air in
commercial and industrial applications.

APPLICATIONS
Clean Air Fume Exhaust Spark
Resistant Construction

PERFORMANCE
Capacities range from 2,100 cfm to
48,400 cfm and up to 0.875 in. wg of
static pressure.

Model TBI-CA belt drive is a good


selection where the motor must be
mounted out of the airstream. Used
with temperatures up to 200F or
contaminated air. Three levels of
construction available.

Model TBI-FS belt drive fans have


motors out of the airstream. They are a
good choice for clean or contaminated
airstreams with temperatures up to 400 F.
Three levels of construction available.

APPLICATIONS
Clean Air Fume Exhaust Spark
Resistant Construction

High Temperature Process UL/cUL


Emergency Smoke Industrial Space
Contaminated Air

PERFORMANCE

PERFORMANCE

Capacities range from 800 cfm to 96,000


cfm and up to 3.25 in. wg of static
pressure.

Capacities range from 4,800 cfm to 76,000


cfm and up to 4 in. wg of static pressure.

APPLICATIONS

TDI STANDARD PERFORMANCE & DIMENSIONAL DATA


MODEL

A (I.D.)

B (O.D.)

C (B.C)

TDI-3-18

183/8

211/16

19

18

TDI-3-20

203/8

231/16

21

19

TDI-3-24

243/8

271/16

25

19

TDI-3-30

TDI-3-36

TDI-3-42

TDI-3-48

303/8
363/8
42
48

339/16
399/16
45
52

32
38
443/16
50

PERFORMANCE IN INCHES WG
.125
.25
.5
.75
.875

MIN/MAX
RPM

1140
1725
1140
1725
860
1140
1725
860
1140
1725
860
1140
1725
680
860
1140
680
860
1140

4190
5873
5336
7018
6215
9028
12599
12478
15600
20634
21839
26098
33394
24214
27070
40594
32194
38105
48408

21
21
27
27

3773
5657
4946
6683
5391
8399
12226
11175
14763
19895
20153
24952
32488
21392
25358
39128
28973
35525
46588

3189
5417
4454
6355
4313
7667
11837
9659
13793
19175
18236
23760
31582
18362
23243
37338
24774
32712
44919

4749

3919

5594

4443

10922

9919

9380

11494
17718

15819

14739

21096
29765

17968
27577

26395

17850
34109

29879

25360

25851
41349

35525

32815

Charts shown
are for level 3
performance.
For complete
performance
ratings for levels
3, 4 & 5, refer
to the CAPS
program or to
catalogs Model
TDI TBI-CA level
3 and Model TBICA level 4 & 5, or
contact your local
representative.

All dimensions in inches.


Performance certified is for installation type D: Ducted inlet, Ducted outlet.
Performance ratings do not include the effects of appurtenances (accessories).

TBI-CA STANDARD PERFORMANCE & DIMENSIONAL DATA


MODEL

A (I.D.)

B (O.D.) C (B.C)

TBI-CA-3L18

183/8

215/8

19

22

21

TBI-CA-3H18

183/8

215/8

19

22

21

TBI-CA-3H18

183/8

215/8

19

22

21

TBI-CA-3H20

203/8

235/8

21

22

23

TBI-CA-3H24

243/8

275/8

25

23

26

TBI-CA-3H30

303/8

335/8

32

24

29

TBI-CA-3H36

363/8

395/8

38

29

33

TBI-CA-3H42

42

45

44

30

37

TBI-CA-3H48

48

52

50

33

40

TBI-CA-3H54

55

59

57

37

47

TBI-CA-3H60

61

65

63

40

50

MIN/MAX
RPM

.125

1890
3000
1610
2710
1189
2290
1056
2225
977
1990
848
1815
763
1710
594
1326
490
1024
476
910
507
970

1914
3225
2171
3874
2698
5583
3126
7186
4931
10858
7473
17648
10388
25929
13266
32585
16808
38804
27099
56134
37656
76735

PERFORMANCE IN INCHES WG
.25
.5
.75
1
1659
3103
1937
3758
2331
5450
2618
7032
4223
10619
6405
17222
8620
25301
10728
31815
14083
37720
23391
54567
33757
74906

1.25

2825

2427

1868

1253

3502

3209

2832

5152

4781

4358

6673

6234

5761

5483

10085

9422

8718

7926

16278 15321

14327

13167

23973 22609

21122

19364

30334 28652

26506

23892

35371 33046

30421

25718

51229 47707

42975

71249 67412

62911

57746

All dimensions in inches.


Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP/kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

52

FANS

Greenheck
Fan
Corporation certifies
that the TDI & TBI-CA
models shown herein
are licensed to bear
the AMCA Seal. The
ratings shown are
based on tests and
procedures performed
in accordance with
AMCA Publication
211 and comply with
the requirements of
the AMCA Certified
Ratings Program.

E
C
B
A O.D.
I.D.
Airow

D
UBFM

Optional
Inlet
B A
Bell

Optional
Inlet/Outlet
Cone

Vane
Axial Fan
C

UBCH

DBFM

DBCH

F
D

G
B

E
A

Centrifugal Utility Fans - SFD/SFB


SFB
STANDARD CONSTRUCTION FEATURES

SFD
STANDARD CONSTRUCTION FEATURES

HOUSING:
Heavy gauge steel housing with Lock-seam
construction
Unit support angles with prepunched mounting holes
Adjustable motor plate
Corrosion resistant fasteners
Entire unit is phosphatized and coated.

HOUSING:
Heavy gauge galvanized steel housing with Lock-seam
construction
Corrosion resistant fasteners
WHEEL:
Forward curved aluminum wheel (Fans with EXP.
motors include: aluminum rub ring, and shaft seal)

BEARINGS, SHAFT, AND WHEEL:


Heavy duty lubricatable, self-aligning ball bearing pillow
blocks
Polished, solid steel shafts
Forward curved fan wheel
(Fans with EXP. motors include: aluminum inlet cone,
aluminum rub ring, and shaft seal)

OPTIONS AND ACCESSORIES

DISCHARGE POSITIONS
(Viewed from Drive Side)
CCW
TH

CW
TH

CCW
TAD

CCW
BH

CW
TAD

CCW
DB

CW
BH

CCW
BAU

CW
DB

CW
BAU

CCW
UB

Vibration isolators
Weatherhood
Belt guard (Belt Drive)
Gravity and motorized dampers - Model WD
Shaft seal with aluminum rub ring
Inlet and outlet guards
Speed controls (Direct Drive)
Heat slinger (Belt Drive)
Drain connection (Belt Drive)
Access doors - Bolted or Hinged (Belt Drive)
Flanged inlets or outlets (Belt Drive)
Dual drives
Extended lube lines (Belt Drive)
Stainless steel shaft (Belt Drive)
Greenheck coatings (See coatings page 117)
C
F

CW
UB

CCW
BAD

CW
BAD

CW
TAU

CCW
TAU

SFB STANDARD CONDENSED PERFORMANCE


& DIMENSIONAL DATA
MODEL

SFB-9

20

24

165/8

14

115/16

65/8

10

13

SFB-10

22

265/8

193/8

167/8

12

11

151/8

SFB-12

22

283/8

213/8

167/8

12

13

151/8

SFB-15

275/8

31

233/8

187/8

13

12

153/8

165/8

SFB-18

367/8

42

307/8

25

18

17

19

223/8

SFB-20

37

46

335/8

273/8

19

157/8 211/8

24

SFB-22

395/8

52

36

30

20

17

23

28

SFB-25

41

57

403/8

335/8

197/8

19

257/8

31

SFB-27

46

611/8

44

375/8

22

213/8

28

33

SFB-30

48

68

48

411/8

22

233/8

31

365/8

MIN/MAX
CFM
300
1400
700
2300
900
2900
1600
4200
2400
6600
3100
7900
4000
10000
5800
13800
9000
17000
10400
20000

E
PERFORMANCE IN INCHES WG
.125
.5
.875
1.5
2
2.5
472
1282
450
1080
373
880
326
658
285
607
263
549
241
508
205
410
225
387
225
398

1422
718
1211
613
979
511
761
454
693
398
617
359
562
308
460
302
431
297
437

1552

1797 1969

1335

1518 1644

1087

1255

858

1000 1098 1186

770

888

976

680
447
617
387
508
370
473
355
476

778

851

919

703

772

832

587
464
539
437
539

646

699

592
494
585

641

All dimensions in inches.


Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).

56

FANS

626

Centrifugal Utility Fans - SWB


FINISH
All structural steel parts are phosphatized and coated with
Greenhecks
Permatector
for a long
lasting finish.

WHEELS
Backward
inclined
wheels are
constructed
of heavy
gauge, single
thickness
blades securely
riveted or
welded to a
heavy gauge
backplate
and wheel cone. Each wheel is statically and dynamically
balanced to precise tolerances.

DRIVES
Drives are sized for a minimum of 150% of driven
horsepower. Machined cast iron motor pulleys are factory
set to the required RPM and adjustable for final system
balancing.

MOTORS
Heavy duty ball bearing motors are carefully matched
to the fan load. Open drip proof, totally enclosed and
explosion proof enclosures are available.

SHAFTS AND BEARINGS


Precision turned, ground and polished solid steel shafts
are sized so the first critical speed is at least 25% over
the maximum operating speed. Stainless steel shafts are
available on Series 200 SWBs. Heavy duty, self aligning
pillow block ball bearings are selected for a minimum L50
life in excess of 200,000 hours at maximum cataloged
operating conditions.

STANDARD CONSTRUCTION
FEATURES

Model SWB Arrangement 10, single width, backward inclined,


utility fans feature:

INLET CONES
The streamlined inlet cone design provides a low turbulence air
intake. This reduces intake losses and sound levels.

HOUSING
Utility fan housings are constructed of heavy gauge steel. Series
100 housings are constructed from galvanized steel. Series 200
fans are constructed of steel and are coated with Permatector.
They are available in CW or CCW rotation and are field rotatable
to the eight standard discharge positions. Housing sides are
bonded to the fan scroll with an airtight lock seam.

HOUSING SUPPORTS AND DRIVE FRAME


Housing supports are constructed of structural steel with
formed flanges for extra strength. Rugged welded steel drive
frame members support the shaft and bearings and provide
rigid reinforcement for the housing. A pivoting motor plate
with adjusting screws make belt tensioning a quick and easy
operation. Prepunched mounting holes are provided for ease of
installation.

OPTIONS AND ACCESSORIES


SWB 100 SWB 200 OPTIONS AND ACCESSORIES

Vibrations Isolators

Weatherhood

Belt Guard

Gravity and Motorized Dampers Model WD (In Stock)


External Inlet Vane Damper &
Companion Flange

Shaft Seal with Aluminum Rub Ring

Inlet and Outlet Guards

Heat Slinger

Drain Connection

Access Doors - Bolted

Access Doors - Hinged

Flanged Inlets or Outlets

Dual Drives

STD

Aluminum Wheel

UL/cUL 705 Electrical with


Weatherhood
UL/cUL 762 Grease - Indoor and
Outdoor Mounting

Performance Baffles

Welded Scroll Construction

Extended Lube Lines

SWB 100 SWB 200 STANDARD FEATURES

HOUSING:
Heavy gauge steel housing with
lock formed seams
Unit support angles with
prepunched mounting holes

Adjustable motor plate

Corrosion resistant fasteners

Slip Fit Outlet

BEARINGS, SHAFT AND WHEEL:


Heavy duty lubricatable, selfaligning ball bearing pillow
blocks

58

Polished, solid steel shafts

Backward inclined steel wheel*

Stainless Steel Shaft


Greenheck Coatings (See coatings
page 117)
Aluminum Construction

Backward inclined aluminum


wheels

UL Listed for Emergency & Smoke


Control

FANS

Centrifugal Utility Fans - SWB


SWB STANDARD CONDENSED
PERFORMANCE & DIMENSIONAL DATA
MODEL
SWB-110

23 265/8 18 167/8 15

11

SWB-113 251/8 31 233/8 187/8 16 105/8

MIN/MAX
CFM
OV

14

SWB-115

28 345/8 25 211/8 18 115/8 157/8

SWB-116

303/8 381/8

227/8 19 131/8 17

28

SWB-118

34

42

307/8

SWB-120

37

46

335/8 273/8 23 157/8 211/8

25

22

145/8 19

SWB-124

41 57 405/8 335/8

25

19 257/8

SWB-130

48

48 411/8

27

233/8 31

SWB-136

553/8 823/8 607/8 485/8

30

285/8 38

68

500
1200
2000
800
1800
2675
1000
2200
3250
1200
2800
4200
1500
3260
4800
1800
3600
5175
2800
5600
8050
4000
7500
11500
7000
12600
17500

641
1540
2567
748
1683
2502
810
1782
2633
789
1842
2763
813
1768
2604
807
1615
2321
848
1697
2440
805
1510
2316
948
1707
2371

C
PERFORMANCE IN INCHES WG
.25
.5
1
1.5
2
2.5
898
1631
2571
824
1496
2136
737
1294
1827
625
1164
1682
545
940
1316
471
723
967
413
668
912
329
501
719
317
488
650

1094
1759
2652
986
1591
2210
880
1388
1899
751
1237
1734
667
1016
1375
591
807
1035
503
727
957
400
552
755
373
527
680

1983 2176 2351 2511


1767 1928 2073 2211
2338

1557 1704 1835 1954


2030 2146
1368 1492 1606 1709
1832 1921 2008
1141 1255 1373 1478
1479 1572 1653
943 1069 1184 1287
1153 1251 1344

D
E

827
917 1005
1039 1112 1180
636
825

713
882

780
938

596
736

658
787

714

All dimensions in inches.


Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission
losses. Performance ratings do not include the effects of appurtenances (accessories).

SWB STANDARD CONDENSED


PERFORMANCE & DIMENSIONAL DATA
MODEL

SWB-210

22 265/8 18 167/8 15

11

SWB-212

23

283/8 213/8 167/8 15

95/8

13

SWB-213 251/8 31 233/8 187/8 16 105/8

14

SWB-215 28 345/8 25 211/8 18 115/8 157/8


SWB-216 303/8 381/8 28

227/8 19 131/8

17

145/8

19

SWB-218

34

42 307/8

SWB-220

37

46 335/8 273/8 23 157/8 211/8

25

22

SWB-222 395/8 52 367/8 30

24

17

23

SWB-224 41 57 405/8 335/8

25

19

257/8

46 611/8 44 375/8

27

213/8

28

48 411/8

27

233/8

31

74 55 441/8

29

25

347/8

SWB-236 553/8 823/8 607/8 485/8

30

285/8

38

SWB-227

SWB-230 48

SWB-233

52

68

Performance for available IN STOCK SIZES


is shown on page 60
PERFORMANCE IN INCHES WG
STOCK MIN/MID
OV
SIZES () MAX/CFM
.5
1
2
3
4
5
500
791 1078 1475
1250
1977 1770 1968 2317 2657 3003 3326

2375
3757 3096 3201
600
729 1020 1372
1650
2007 1775 1943 2262 2569 2868 3147

2850
3467 2867 2968 3169
800
785
930 1279
2200
2161 1680 1821 2085 2346 2615 2876
3425
3364 2478 2575 2759
1000
810
839
2575
2086 1447 1580 1829 2079 2329
4375
3545 2302 2386 2547
1200
789
762
3300
2171 1359 1472 1696 1919 2143 2348

5700
3750 2208 2279
1500
813
690
3600
1953 1117 1233 1459 1682 1888 2069
6000
3255 1737 1810 1949 2084
1800
807
630
849
4600
2063 1072 1171 1365 1556 1754 1930

7800
3499 1704 1767 1883
2300
848
587
777
4550
1678 841
952 1173 1370 1554 1733
9050
3339 1508 1566 1675 1785
2800
848
515
7200
2183 914
992 1138 1282 1424 1573

11050
3350 1333 1384 1486 1586
3800
947
489
642
8350
2082 799
872 1012 1167 1307 1430
13550
3379 1221 1267 1358
4000
805
418
12000
2417 816
873
985 1090 1195
19000
3827 1238 1274
6000
991
398
508
13000
2148 661
720
828 933 1035 1132
21000
3470 1006 1044 1119
7000
948
362
472
13000
1761 520
586
703 820 945
25000
3387 911
945 1013

O.D.

All dimensions in inches.


Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
FANS

59

Centrifugal Utility Fans - SWB


SWB PERFORMANCE DATA - IN STOCK

Order stock products online at


www.greenheck.com/qd

Stock Model SWB fans come with CW-TH rotation and discharge and include: aluminum wheel
(SWB-210), steel wheel (SWB-212-224), weatherhood and UL/cUL 705.
MODEL

SWB-210-LMDX-QD

SWB-212-LMDX-QD

SWB-216-LMDX-QD

SWB-220-LMDX-QD

SWB-224-LMDX-QD

RPM

HP

MAX
BHP

1670
1833
2103
2408
2650
3033
3339
1500
1651
1770
1891
2029
2169
2265
2376
2486
2600
2716
2857
2998
982
1124
1287
1347
1416
1526
1621
1705
1784
1905
2042
2200
815
876
934
980
1028
1100
1176
1230
1295
1395
1482
1622
1757
1942
681
715
749
799
858
895
944
1014
1080
1175
1281

1/3

1
1
2

1/3

1
1
1
1
1
2
2
1/3

1
1
1
1
2
2
3
3
5

1
1
1
1
2
2
3
3
5
5
7

1
1
1
1
2
2
3
3
5
5

.25
.33
.50
.75
1.0
1.5
2
.251
.334
.414
.501
.612
.751
.863
1.001
1.150
1.316
1.501
1.740
2.001
.334
.501
.752
.861
1.001
1.252
1.503
1.748
2.003
2.439
3.004
3.756
.502
.621
.752
.869
1.003
1.228
1.501
1.718
2.004
2.506
3.004
3.939
5.007
6.76
.753
.870
1.002
1.216
1.506
1.709
2.005
2.482
3.003
3.867
5.011

.25
1246
1383
1608
1860
2059
2372
2621
1443
1606
1734
1867
2017
2169
2273
2392
2509
2629
2751
2899
3047
2396
2805
3267
3435
3628
3933
4195
4426
4643
4974
5348
5778
3551
3860
4156
4389
4631
4991
5369
5636
5956
6447
6872
7554
8209
9107
5420
5739
6057
6516
7050
7384
7824
8449
9037
9878
10813

.5
1158
1307
1542
1801
2004
2322
2576
1323
1504
1645
1786
1940
2092
2196
2315
2434
2559
2686
2840
2992
2140
2599
3092
3267
3468
3786
4057
4295
4519
4858
5240
5678
3179
3527
3856
4113
4366
4742
5136
5414
5746
6253
6690
7389
8056
8971
4878
5236
5589
6093
6664
7019
7485
8143
8758
9623
10580

.75
1046
1214
1471
1744
1952
2277
2533
1185
1388
1538
1685
1851
2016
2128
2257
2377
2501
2627
2779
2930
1773
2352
2897
3089
3307
3639
3917
4163
4392
4740
5031
5576
2653
3114
3499
3779
4061
4475
4903
5195
5536
6056
6505
7220
7920
8834
4198
4631
5028
5592
6227
6614
7120
7807
8442
9345
10339

PERFORMANCE IN INCHES WG
1
1.5
2
922
1108
737
1388
1198
788
1680
1528
1359
1900
1775
1629
2231
2135
2023
2491
2408
2315
990
1252
1421
1048
1583
1313
1757
1544
1170
1928
1742
1490
2044
1871
1655
2176
2016
1833
2306
2153
1986
2440
2293
2140
2574
2434
2293
2730
2603
2470
2884
2770
2643

2.5

1111
1469
1894
2209

1237
1764
2092

1385
1842

1298
1574
1772
1962
2132
2326
2513

1435
1718
1929
2164
2367

1620
1975

1996
2676
2887
3117
3473
3774
4034
4267
4621
5019
5474

2284
2634
3092
3438
3721
3980
4368
4800
5270

2153
2976
3347
3652
4083
4537
5045

3191
3737
4257
4800

3231
3904
4529

3732

2994
3368
3709
4174
4625
4937
5308
5866
6323
7051
7746
8692

3242
3934
4342
4781
5398
5906
6703
7439
8407

3994
4832
5433
6300
7083
8128

2781
4779
5842
6706
7792

5223
6262
7451

6597

3650
4299
5013
5726
6151
6692
7435
8118
9054
10072

3775
4874
5671
6583
7349
8401
9512

5222
6263
7650
8870

6650
8150

7188

Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP) does not include
transmission losses. Performance ratings do not include the effects of appurtenances (accessories).

For complete product information


refer to the CAPS program or to
catalog Centrifugal Backward
Inclined - Model SWB Utility
Fans, or contact your local
representative.
60

FANS

UL/cUL 705
UL/cUL 762
E40001-SWB

Centrifugal Fans - Selection Guide


FAN WIDTH

ROTATION

SINGLE WIDTH (SW) Single Inlet - Single Outlet

Choice between clockwise (CW) and counterclockwise (CCW) as determined from the drive
side. Rotation changes discharge location as
illustrated below.

Used in a wide range of applications


Contaminated air, elevated temperatures, moisture
content, kitchen exhaust, fume exhaust
Typically used in ducted in - ducted out applications, but
can be unducted at either end as needed
DOUBLE WIDTH (DW) Double Inlet - Single Outlet
Generally used for high volume applications or
air handlers
Clean air applications only due to bearings being
located in the airstream
Typically applied as free inlet - ducted outlet

SPARK RESISTANT CONSTRUCTION


SPARK C - Includes aluminum inlet cone and rub ring
SPARK B - Includes aluminum wheel and rub ring
SPARK A - All airstream parts constructed from aluminum
(Consult factory for availability)

ARRANGEMENTS
ARRANGEMENT 10

SINGLE WIDTH
Backward Inclined or Airfoil Wheel

This is the most common fan


arrangement. Motor is mounted
on the fan under the bearing
pedestal and can be enclosed
with a motor cover, limited
motor frame sizes, smallest
overall package size. No
mounting base required.

ARRANGEMENT 9

Motor position determined


from the drive side. Letter
assignment is independent
of discharge position and fan
rotation.

FAN
Z

W
Y

DISCHARGE POSITIONS
Chart shows discharge positions available on QB
centrifugal fans. Determined from the drive side.
Some models and sizes allow for field rotation.

BAU

UB

TAU

TH

WHEEL TYPES
Motor is mounted on the side
of the bearing pedestal, limited
motor frames sizes, smaller
overall size than arrangement 1.
No mounting base required.

ARRANGEMENT 1

SINGLE WIDTH
Backward Inclined or Airfoil Wheel

Motor is mounted on a
structural base. Mounting base
required. See page 116 for
more details.
ISOLATION BASE

ARRANGEMENT 3

SINGLE WIDTH AND DOUBLE WIDTH


Backward Inclined or Airfoil Wheel

ISOLATION BASE

DOUBLE
WIDTH

CW

MOTOR POSITIONS
(ARR 1 & 3 ONLY)

BH

SINGLE WIDTH
Backward Inclined or Airfoil Wheel

SINGLE
WIDTH

CCW

DW (when compared
to SW) can supply an
equal amount of air with
a smaller wheel diameter
resulting in lower overall
unit size. Bearing
located in the airstream
limits temperatures and
does not permit spark
resistant construction.
Mounting base required.
See page 116 for more
details.

Backward Inclined Wheel


Centrifugal, non-overloading
style with single thickness flat
blades. Most versatile wheel.
Excellent for clean, high-temp, or
contaminated air.
Airfoil Wheel
Centrifugal, non-overloading style
with Airfoil shaped blades. Higher
operating efficiencies. Used for
clean air applications.
Industrial Process Open Wheel
Open material handling wheels
are suitable for material handling
such as wood chips, abrasives
and dust.
Industrial Process Wool Wheel
The wool wheel, or backplate
material handling wheel, is
designed for handling long,
fibrous, stringy material such as
paper or yarn.
Industrial Process Air Handling
Wheel
Air handling wheels are designed
for applications ranging from
clean air exhaust to light material
handling.
FANS

61

RADIAL
AL

I
AX

RAD

IAL

RAD

AX

AL

IAL

15.625

Airow
10.50

7.625

12.00
18.50

Direct Drive - S
Sidewall Propeller direct drive fans have varied model configuration arrangements available to handle exhaust and supply
requirements. Propellers are available in fabricated aluminum, fabricated steel, or cast aluminum blades depending on
the level of construction. Three levels of construction are available. Direct drive fans are often preferred for jobs where
maintenance access is difficult.

LEVEL 1 - SIZE 8-12 - D, G, E Motor Speeds


F*

B*
C*

A Sq.

Exhaust

Supply

Airow

Airow

LEVEL 1 - SIZE 12-24 - A, B, C Motor Speeds, LEVELS 2 & 3


B*
C*

A sq.
G sq.

F*
D

PERFORMANCE
Performance capabilities range
from 115 cfm to 51,206 cfm
and up to 1 in. wg of static
pressure.

Exhaust

Supply

Airow

DIRECT DRIVE S STANDARD CONDENSED PERFORMANCE


RANGES & DIMENSIONAL DATA - STEEL PROPELLER

Airow

Performance for available IN STOCK SIZES is


shown on page 67
PERFORMANCE IN INCHES WG

B* EXHAUST F* SUPPLY C* EXHAUST


LEVEL
LEVEL
LEVEL
MODEL A PANEL
1

2&3

2&3

2&3

E EXHAUST
LEVEL
1

2&3

STOCK
SIZES
()

S-8

13

83/8

S-10

15

103/8

S-12

18

10

131/8

123/8

S-14

20

11

14

143/8

S-16

22

11

13

14

14

87/8

10

163/8

163/8

S-18

24

14

13

14 14 107/8

10

183/8

183/8

S-20

26

17

17

18

18

11

13

20

20

S-24

32

20

20

21

21

125/8

13

243/8

245/8

S-30

38

20

21

163/8

305/8

S-36

44

20

28

163/8

365/8

S-42

50

26

28

18

425/8

S-48

56

265/8

28

205/8

49

301/8

227/16

553/8

S-54

62

28

MIN/MAX SONES
#
PROP
RPM
@ 0 in. BLADES PITCH
1050
1550
1050
1550
860
1750
860
1750
860
1750
860
1750
860
1750
860
1750
860
1160
860
1160
860
860
860
860
690
860

1.5
4.9
3.2
5.9
4.0
8.7
5.9
14.8
7.4
23
8.7
23
10.8
35
9.1
41
23
33
27
40
30
41
43
53
52
54

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
4
4
4
4

40
40
40
40
32
32
40
36
36
30
34
21
28
35
32
15
18
20
7
14
2
27
7
22
20
16

.1

311
459
626
924
804
1636
1189
2734
2003
3531
2661
4177
3133
7266
5000
9537
9698
13905
9985
18400
8673
28811
18124
34332
41542
45612

126
351
361
800
512
1515
919
2615
1732
3344
2202
4015
2823
6980
4540
9310
9066
13434
9347
17945
7991
27924
17081
33166
39736
44465

.15

.25

255

167

726
349
1448
649
2553
1433
3250
1874
3931
2641
6837
9197
8707
13198
9012
17718
7632
27480
16565
32583
38845
43892

1282
408
2422
849
3058

.5

948
1829
2303

3683
2085
6543

3059

8961
7892
12665
8255
17263
6888
26533
15499
31257
37177
42745

8315

5453
6559

11144
5325
15787 10993
4937
24002
12067
27990
32089
39103 30171

*May vary due to motor sizes. All dimensions in inches.


Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories).
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are
for installation type A: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

For complete product information


refer to catalog Sidewall Propeller
Fans, or contact your local
representative.
66

FANS

Greenheck Fan Corporation certifies that


the S models shown herein are licensed
to bear the AMCA Seal. The ratings
shown are based on tests and procedures
performed in accordance with AMCA
Publication 211 and AMCA Publication
311 and comply with the requirements of
the AMCA Certified Ratings Program.

UL/cUL 705
E40001-S

A sq.
A sq.

B
C

F
D

Exhaust

Supply

Airow

Airow

E
E

Exhaust

Supply

Airow

Airow

D
B

D
F

Belt Drive - SB
BELT DRIVE SB CONDENSED PERFORMANCE RANGES &
DIMENSIONAL DATA - STEEL PROPELLER
Performance for available IN STOCK SIZES is shown on page 70
MODEL A PANEL

B EXHAUST F SUPPLY C EXHAUST


LEVEL
LEVEL
LEVEL
1&2

SB-20

SB-24

26

32

19

19

3
-

19

1&2
20

20

1&2
17

3
-

E EXHAUST
LEVEL
1&2

20 17 167/8 1

20

245/8

STOCK SIZES
LEVEL
()

245/8

SB-30

38

22

21

21

20

18

191/8 1

305/8

305/8

SB-36

44

21

28

23

27

20

21

365/8

365/8

SB-42

50

25

28

23

29

22

18

42

42

SB-48

56

25

28

23

29

22

26

48

48

SB-54

62

25

35

24

36 22 32

55

55

SB-60

68

28^

35

24^

35

22

61

61

SB-72

82

35

35

73

30

303/8 21/8

1L
1H
2L
2H
1L
1H
2L
2H
3L
3H
1L
1H
2L
2H
3L
3H
1L
1H
2L
2H
3L
3H
1L
1H
2L
2H
3L
3H
1L
1H
2L
2H
3L
3H
1L
1H
2L
2H
3L
3H
2L
2H
3L
3H
3L
3H

PERFORMANCE IN INCHES WG

MAX MAX SONES


RPM
@ 0 IN.
1085
1221
1241
1391
863
1010
987
1148
1127
1485
685
882
950
1221
1100
1432
550
694
693
870
819
1321
424
533
723
906
762
951
355
429
608
731
686
862
343
377
508
561
619
779
399
521
503
659
492
559

17.9
20
22
25
17.4
19.9
24
25
27
28
18.7
22
32
36
41
49
17.6
20
27
34
28
59
18.8
21
39
56
33
43
15.4
19.3
36
38
44
54
17.3
19.0
44
72
56
75
31
47
72
70
58
75

.125

.25

5549
4587
6347
5226
7176
5281
8207
6002
8873
7745
11334
10077
15719
13951
17423
15173
15867
15252
19992
19121
22543
23810
19759
18407
33693
31290
32562
28763
22875
21826
39177
37192
45087
39021
30129
28831
44623
42904
54526
50022
53242
45754
67119
57873
86853
84448

4918
4277
5763
4953
6367
4818
7522
5605
8337
7424
10252
9341
14985
13414
16709
14820
14112
13797
18743
18095
21377
23304
16705
16388
32120
30259
31112
27821
19219
18906
37271
35536
43261
37910
26014
25408
41857
40952
52198
48395
47929
43208
62922
55734
83860
81436

4269
3872
5325
4639
5345
4193
6731
5121
7685
7073
8621
8560
14151
12889
15991
14467
11681
12111
17105
16735
20081
22798

.5

.75

2514

1063

3740

1885

2108

903

3342
5568
6270

1852

910

5208

3469

1138

11760
11734 9979
14240 11253
13585 12445 11175

13871
16505
21710 20232 18473

13751
30386 26322
29057 26258 22859
29634 25934
26939 25062 22588 19605
13505
35157
33823
41495
36799
16537
19923
39088
38410
49736
47032
41675
41233
58582
54054
80837
79030

29209
29713 21822
36866
34248 30989 27269

28363
31961
42826 33869
44548 41129 35731
34834
50625 45469
73537
74243 67312

All dimensions in inches.


^ = LEVEL 2 ONLY
Please note: Optimum selections shown in bold.

BELT DRIVE SBC CONDENSED PERFORMANCE RANGES &


DIMENSIONAL DATA - CAST ALUMINUM PROPELLER
MODEL A PANEL B EXHAUST F SUPPLY C EXHAUST

SBC-24

32

19

20

155/8

245/8

SBC-30

38

21

20

17

305/8

SBC-36

44

28

27

23

365/8

SBC-42

50

28

29

23

42

SBC-48

56

28

29

27

48

SBC-54

62

35

36

30

55

SBC-60

68

35

35

287/16

61

SBC-72

82

35

35

28

21/8

73

LEVEL
3L
3H
3L
3H
3L
3H
3L
3H
3L
3H
3L
3H
3L
3H
3L
3H

MAX SONES @
RPM
0 IN.
1194
1396
1262
1616
1183
1480
916
1259
908
1182
727
856
620
775
578
795

24
26
40
47
51
58
42
57
50
75
61
61
56
67
72
104

IN STOCK SIZES not available for SBC

0
8225
7958
17403
15633
27371
25310
31268
29396
45707
43876
50893
50181
61815
59655
87026
85182

PERFORMANCE IN INCHES WG
.125
.25
.5
.75
7787
7563
16631
15111
26355
24537
29539
28560
43334
42275
49204
48653
58572
56913
81173
82395

7253
7126
15835
14596
25194
23750
27517
27589
40528
40858
46849
47125
55353
54624
73547
79290

5677
6208
13841
13579
22246
22116
23037
25445
34663
37667
41235
43599
44586
49309
53266
73185

1836
5051
11164
12487

11270

20313

18538

22880

19614

34068

29382

39366

33873

42537

31181

65974

55871

1966

All dimensions in inches. Please note: Optimum selections shown in bold.


Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the
effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per
AMCA Standard 301. Values shown are for installation type A: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
FANS

69

Belt Drive - SB

Order stock products online at


www.greenheck.com/qd

SB PERFORMANCE DATA - IN STOCK


MODEL NUMBER

MOTOR
HP

IN STOCK SIZES are belt drive exhaust and include steel propellers UL/cUL 705.

PERFORMANCE IN INCHES WG

FAN
RPM

MAX
BHP

F.A.
SONES

.1

.125

705

.17

13.3

3606

2835

2450

861

.30

14.3

4404

3794

3671

3455

889

.33

14.9

4547

3949

3830

3654

3067

947

.40

16.1

4843

4270

4155

4043

3647

1021

.50

17.0

5222

4675

4566

4461

4180

3746

1085

.60

17.9

5549

5021

4918

4816

4620

4269

773

.17

9.8

2904

2452

2292

2112

1595

924

676

304

953

.30

16.1

3580

3246

3148

3033

2769

2468

2001

1159

656

998

.33

16.7

3749

3436

3342

3243

3006

2727

2398

1588

873

392

1039

.40

17.2

3903

3607

3517

3427

3211

2954

2675

2037

1064

602

1107

.50

18.0

4159

3885

3805

3720

3533

3315

3065

2599

1367

934

501

1221

.60

20

4587

4339

4277

4203

4049

3872

3675

3333

2514

1456

1063

562

.17

12.3

4673

3577

688

.30

12.8

5721

4890

4659

4378

.15

.2

.25

.3

.375

.5

.625

.75

SBE-1L20-LMDX-QD
705-1085 RPM

1/3

3711

SBE-1H20-LMDX-QD
773-1221 RPM

1/3

SBE-1L24-LMDX-QD
562-863 RPM

1/3

711

.33

13.2

5912

5114

4891

4654

759

.41

14.1

6311

5572

5367

5158

4621

811

.50

15.6

6744

6062

5872

5677

5255

4528

863

.60

17.4

7176

6545

6367

6187

5820

5345

448

.25

10.9

7413

5790

475

.30

11.6

7860

6394

5880

491

.33

12.1

8125

6742

6249

523

.40

13.0

8654

7427

6970

6503

564

.50

14.3

9333

8261

7862

7436

598

.60

15.5

9895

8898

8583

8185

7366

645

.75

17.2

10673

9766

9508

9190

8446

7562

685

.90

18.7

11335 10496

10253 10009 9332

8622

361

.34

11.8

10415

7958

6849

384

.41

11.8

11078

8915

8018

6662

412

.5

12.7

11886

9913

9250

8354

438

.61

13.6

12636 10809

10290

9572

471

.76

14.5

13588 11925

11442 10947 9408

1/3

SBE-1L30-LMDX-QD
390-685 RPM

1/3

SBE-1L36-LMDX-QD
390-685 RPM

500

.90

15.3

14425 12890

12435 11981 10808

518

1.01

16.1

14944 13482

13044 12605 11569 10084

8915

550

1.20

17.6

15867 14525

14113 13699 12873 11682

1
9934

Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW) does not include transmission losses. Performance ratings do not include
the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA
Standard 301. Values shown are for installation type A: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

70

FANS

Sidewall Fan Accessories - S

Weatherhood*
(45 Exhaust
only shown)

W.O.

Damper Guard*
Damper

Wall Housing and OSHA Guard - (Std.)

WALL HOUSING DIMENSIONAL DATA


SIZE
8
10
12
14
16
18
20
24
30
36
42
48
54
60
72

WALL
A
13
15
18
20
22
24
26
32
38
44
503/8
563/8
623/8
683/8
831/8

WALL HOUSING &


ACCESSORIES

HOUSING DAMPER GUARD 45 WEATHERHOOD 90WEATHERHOOD DAMPER


SIZE
B* W.O.
C
D
E
F
WIDTH
H
J
19 14
5
10
13
11
10
163/8
12
10 x 10
19 16
6
12
14 7/8
133/8
12
18
14
12 x 12
23 19
5
14
163/8
155/8
14
203/8
163/8
14 x 14
26 21
6
16
17
175/8
16
22
183/8
16 x 16
27 23
6
18
193/8
195/8
18
25
203/8
18 x 18
28 25
6
20
22
215/8
20
27
223/8
20 x 20
32 27
6
22
24
235/8
22
29
243/8
22 x 22
37 33
6
26
267/8
303/8
291/8
36
31
26 x 26
38 39
6
32
291/8
36
351/8
401/8
377/8
32 x 32
39 45
63/4
38
33
42
411/8
45
437/8
38 x 38
44 51
9
44
35
48
471/8
49
497/8
44 x 44
44 57
9
50
403/8
545/8
53
55
56
50 x 50
52 63
7
56
44
607/8
59
61
62
56 x 56
3
54 69
7
62
48 /8
67
655/8
66
683/8
62 x 62
60 84
7
74
53
79
781/8
721/8
807/8
74 x 74

Wall housings are the safest and most


efficient platform for mounting of
sidewall propeller fans and their optional
accessories. Wall housings allow for a
wide range of mounting arrangements to
meet specific applications, and can be
mounted flush inside, flush outside, or
centered in wall. Standard construction
is of galvanized steel.
*Select only one. Shown together for illustration only.

* B dimension will increase by 6 in. when a heavy duty motorized backdraft damper is specified.
For complete dimensional information refer to submittal. All dimensions given in inches.

W.O.

D
J

Wall Collar

Damper

Motor - Side Guard

WALL COLLAR DIMENSIONAL DATA


SIZE
8
10
12
14
16
18
20
24
30
36
42
48
54
60
72

WALL COLLAR
(WI - STOCK ONLY)
A
B*
W.O.
127/8 161/8 14
147/8 161/8 16
177/8 161/8 19
197/8 183/8 21
217/8 183/8 23
237/8 183/8 25
257/8 183/8 27
317/8 183/8 33
377/8 183/8 39
437/8 18 45
497/8 18 51
557/8 187/8 57
617/8 201/8 63
677/8
21
69
817/8
22
83

DAMPER
GUARD
C
D
5
10
6
12
5
14
6
16
6
18
6
20
6
22
6
26
6
32
6
38
9
44
9
50
7
56
7
62
7
74

Weatherhood*
(90 Turndown
shown)
Damper
Guard*

C
G

45
90
MOTOR-SIDE DAMPER
WEATHERHOOD
WEATHERHOOD
GUARD
SIZE
SQ.
E
F
WIDTH
H
J
G**
13 11
10
163/8
12
81/16
10
14 7/8 133/8
12
18
14
13
12
163/8 155/8
14
203/8
163/8
18
14
17 175/8
16
22
183/8
18
16
193/8 195/8
18
25
203/8
18
18
22
215/8
20
27
223/8
18
20
24 235/8
22
293/4
243/8
18
22
267/8 303/8
291/8
36
31
18
26
291/8 36
351/8
401/8
377/8
20
32
33
42
411/8
45
437/8
23
38
35 48
471/8
49
497/8
24
44
403/8 545/8
53
55
56
27
50
44 607/8
59
61
62
33
56
483/8
67
655/8
66
683/8
33
62
53 79
781/8
721/8
807/8
33
74

** Dimensions are for exhaust fan guard. See CAPS for supply fan and optional OSHA motor side guard dimensions.
For complete dimensional information refer to submittal. All dimensions given in inches.

WALL COLLAR &


ACCESSORIES
Wall collars offer an alternate
method for mounting sidewall
propeller fans and the optional
accessories shown here.
Standard construction is of
galvanized steel.
*Select only one. Shown together for
illustration only.

FANS

71

TB

Tall Base Option


A sq.

2 1/2 in.

Tall Base Option


A sq.

Belt Drive Model Number Code


The model number system is designed to completely identify the fan. The correct code letters must be specified to
designate belt drive with exhaust, supply or filtered supply air configurations. The remainder of the model number is
determined by the size and performance.

RB E - 2 L 24 - 7
Hooded Roof Propeller
Belt Drive
RB - Fabricated Propeller
RBC - Cast Propeller
(Level 3 only)
E - Exhaust
S - Supply
F - Filtered Supply
Level of
Construction
1, 2, 3

Motor HP
4 = 1/4
3= 1/3
5= 1/2
7= 3/4
10 = 1

15 = 11/2
20 = 2
30 = 3
50 = 5

Fan Size
Propeller Type
L - Low
H - High

75 = 7 1/2
100 = 10
150= 15
200= 20

Hooded Propeller Roof Fans - R & RB


RBE STANDARD CONDENSED PERFORMANCE RANGES & DIMENSIONAL DATA
MODEL

RBE-20

RBE-24

RBE-30

RBE-36

RBE-42
RBE-48
RBE-54

A
SQ.
30

34

40

46

52
58
64

27

29

34

39

42
43
49

TALL
BASE
TB
44

46

51

56

59
60
66

RBE-60

70

50

67

RBE-72

82

53

70

ROOF
OPENING LEVEL
SQ.
1L
1H
54 x 51
22
2L
2H
1L
1H
2L
66 x 63
26
2H
3L
3H
1L
1H
2L
75 x 75
32
2H
3L
3H
1L
1H
2L
88 x 87
38
2H
3L
3H
2H
86 x 99
44
3L
3H
2H
93 x 111
50
3L
3H
2H
112 x 111
56
3L
3H
2H
124 x 123
62
3L
3H
3L
136 x 135
74
3H
WxL

MAX
RPM

SONES
@ 0 in.

1025
1348
1171
1550
775
1152
888
1311
1278
1461
686
895
864
1125
996
1239
550
679
693
856
922
1357
888
868
898
726
690
842
557
650
795
536
582
677
508
606

16.9
24
21
31
15.7
29
19.2
34
26
29
19.4
23
28
34
30
36
17.6
18.9
27
34
37
55
44
43
37
37
32
45
68
39
61
36
41
49
52
59

PERFORMANCE IN INCHES WG
0
4524

.125
4095

5169

4791

6148

5461

7045

6450

4426
4472
5636

7329

6925

6503

9795

8487

6556
6992
10213

12336 11329
11661 10987
12937 12330
13589 11638

.25
3562
3422
4408

17123 15590

10241
11711
9444
9945
13986

19176
21485
27562
28037

18328
20919
26336
27045

17452
20379
24827
25858

32445
33135
35818
37500
44393
45489
41920
56644

30758
31527
34434
35114
42106
43976
39092
53977

28605
29742
32994
32419
39668
42592
36208
50800

82283 78327

74199

.5

.75

1.5

2733
3559

2637

4429
5502
5312

3901

4176
6789
8113

5499

10290

8799

5286
10416
11341
15415
19308
22117
23096
24938
25450
30055
26549
34363
39704
29935
43880
43808
65283
64145

7132
12091
17650
19266
19271
19108
20437

7146

15847
15631
16508
15888

9159
9261

27145
19845

24208

15499

36650
22580
36744
38756
54395
58110

32982

24769

33603
50925

27099

RBS STANDARD CONDENSED PERFORMANCE RANGES & DIMENSIONAL DATA


MODEL

RBS-20

RBS-24

RBS-30

RBS-36

RBS-42
RBS-48
RBS-54

A
SQ.
30

34

40

46

52
58
64

27

29

34

39

42
43
49

TALL
BASE
TB
44

46

51

56

59
60
66

RBS-60

70

50

67

RBS-72

82

53

70

ROOF
OPENING LEVEL
SQ.
1L
1H
54 x 51
22
2L
2H
1L
1H
2L
66 x 63
26
2H
3L
3H
1L
1H
2L
75 x 75
32
2H
3L
3H
1L
1H
2L
88 x 87
38
2H
3L
3H
2H
86 x 99
44
3L
3H
2H
93 x 111
50
3L
3H
2H
112 x 111
56
3L
3H
2H
124 x 123
62
3L
3H
3L
136 x 135
74
3H
WxL

MAX
RPM

SONES
@ 0 in.

1052
1366
1205
1564
779
1157
891
1322
1278
1420
689
906
869
1136
995
1243
548
621
690
783
919
1417
878
870
899
733
689
851
557
646
779
551
582
695
504
620

22
26
27
34
17.9
25
23
37
31
31
22
29
31
39
33
52
20
21
33
35
45
82
58
53
54
44
49
74
59
52
81
40
54
64
55
60

PERFORMANCE IN INCHES WG
0
5328

.125
4700

6103

5570

7083

6150

8101

.25
3867
3683
4975

.5

.75

4120

2320

1.5

2771
3732
2862

7324

4819
4945
6382

8102

7725

7269

4651
5640
5851

10564

9548

13324

12659

7533
7808
11522

12586
13247
15072

12039
12820
13722

18977

18189

11406
12365
9918
9206
16276

20113
21830
30194
29702

19360
21376
29299
28718

18515
20921
28159
27706

36434
34926
38705
42225
46542
50138
44697
59743

34712
33452
37638
40222
44457
49056
51638
57009

33316
31699
36571
36742
41924
47590
38407
54205

86594

82943

78711

4289
8793
8431
11108

5659
8746

6634

9350
10084
15273
19774
23387
24913
24117
29248
25920
34181
26638
34736
42686
30068
45051
46256
67046
62164

18437
18669
19834
19830
21021
19638
29385
15561
26145
36983
20414
36007
39019
52057
54641

16367
11382
15792
25477
31628

18703

27724
32640
45820

All dimensions in inches.


For performance for fan models RBCE, RBCS, RBCF, RBF, RCE3, RCS3, RE2, RS2 refer to catalog Hooded Propeller Roof Fans.
Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW) does not include transmission losses. Performance ratings
include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft.
(1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free
FANS
inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

73

B
B

Curb
Cap

Curb
Cap

RDU/RBU/RBUMO
RBU STANDARD CONDENSED PERFORMANCE & DIMENSIONAL DATA
MODEL

C
LEVEL

1&2
RBU-20

RBU-24

RBU-30

RBU-36

RBU-42
RBU-48

27

24

311/8

15

26

373/8

16

16

16

237/8

193/8

38

56

16

15

33

495/6

15

15

30

43

237/8

193/8

40

PERFORMANCE IN INCHES WG

CURB
ROOF
SONES MAX
LEVEL
CAP OPENING
@ 0 IN. RPM
30

34

40

46

52
58

24

28

34

40

46
52

RBU-54

625/8

45

19

267/8

66

60

RBU-60

68

48

21

27

72

66

1L
1H
2L
2H
1L
1H
2L
2H
3L
3H
1L
1H
2L
2H
3L
3H
1L
1H
2L
2H
3L
3H
2L
3L
3H
2L
3L
3H
2L
3L
3H
3L
3H

19.3
21
19.3
21
18.2
28
22
32
24
28
18
27
30
34
38
50
20
28
29
41
61
66
39
33
57
30
45
51
30
50
54
43
48

1084
1443
1084
1443
808
1351
924
1477
1135
1460
695
963
964
1213
1154
1471
547
806
689
1014
976
1401
718
652
1011
594
690
876
496
609
811
504
673

.125

5235
4295
5235
4295
6791
7382
7766
8071
8900
8358
11108
10943
15408
13783
17745
16466
15252
16441
19212
20683
26247
23827
32495
26765
28701
37987
44597
40049
44670
56220
52094
64326
58475

4616
4041
4616
4041
5985
7037
7078
7755
8197
7931
9534
10166
14272
13173
16855
15907
13326
15195
17866
19637
25093
23230
30584
24942
27743
36154
42591
38737
41495
53570
50598
61083
56434

.25

.5

.75

3669
3669
6491
6127
7286
6411
7427
7459
6435
7845
9279
7021
13148
12515 11071
15865
15355 14335
13830
15917
18743
23979
22633
28793
22691
26759
33838
40288
37415
37122
50445
49059
56176
54119

16145
21093
21037
23522

4404

9315
13226

11816

19260
14105

17598

24540
28240
35204
34563

21672
29650
31092

27129

42530
44746

27190
40046

35353

48865

43082

35057

All dimensions in inches.

RBUMO STANDARD CONDENSED PERFORMANCE & DIMENSIONAL DATA


MODEL

CURB
CAP

ROOF
OPENING

RBUMO-20

27

43

19

29

24

RBUMO-24

311/8

455/6

17

33

28

RBUMO-30

RBUMO-36

RBUMO-42

RBUMO-48

373/8

43

495/6

56

51

55

595/8

635/6

19

19

195/8

21

39

45

51

57

34

40

46

52

RBUMO-54

625/8

705/8

22

66

60

RBUMO-60

68

75

23

72

66

LEVEL

SONES
@ 0 IN.

MAX
RPM

1L
1H
2L
2H
1L
1H
2L
2H
3L
3H
1L
1H
2L
2H
3L
3H
1L
1H
2L
2H
3L
3H
2L
3L
3H
2L
3L
3H
2H
3L
3H
3L
3H

18.3
19.6
18.3
19.6
17.7
24
22
29
23
26
17.9
26
28
32
36
49
19.3
27
28
39
49
61
38
42
53
29
40
47
34
46
50
40
46

1060
1393
1060
1393
771
1259
883
1377
1089
1370
673
929
933
1167
1109
1420
530
784
668
988
943
1343
701
750
960
587
676
842
585
591
776
493
650

4797
3937
4797
3937
6234
6540
7140
7153
7827
7163
9706
10221
13456
12839
15679
15223
14236
15501
17943
19535
24356
22439
29635
29671
26600
34761
40135
37206
38905
51679
48021
61784
55174

PERFORMANCE IN INCHES WG
.125
.25
.5
.75
3979
3475
3979
3475
5271
6066
6308
6723
7094
6707
8202
9265
12436
12092
14675
14657
12403
14137
16499
18453
23220
21888
28136
27925
25403
32809
38262
35684
36257
48380
46336
57265
52967

Please note: Optimum selections shown in bold.


All dimensions in inches. *May be greater depending on motor. **RBUMO = 1/2 in. less. Dimension A - given is the inside
dimensions of the curb cap. The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing.
Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW) does not include
transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings
shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301.
Values shown are for installation type A: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone
ratings only.

5530
5332
6273
6223
6208

5096
4968

8301
11279
11308 9633
13659
14044 12712 11285
12677
14852
17368
22077
21337
26190
26138
24222
30166
35865
34269
33184
44763
44533
51778
50458

14948
19334
19655
21646
21824
21531
24091
30524
31241

9613

17885
15694

15850

18596

14837

21518
27087

20830

36436
40247 35308
44728 37535

FANS

26609

75

1 3/4 in.

Tube Axial Upblast Roof Exhaust - TAUD/TAUB/TAUB-CA


Model TAUD direct drive tube axial upblast roof exhaust fans feature cast aluminum propellers and are designed to efficiently
remove and disperse contaminated air. They are best suited for exhausting relatively clean, dry and cool air.
Model TAUB belt drive tube axial upblast roof exhaust fans are designed to efficiently remove and disperse contaminated air.
The TAUB L/H is available with high temperature options that meet IRI, SBCCI, or can be UL listed as a Power Ventilator for
Smoke Control Systems.
STANDARD
TAUD TAUB-CA TAUB-L/H
CONSTRUCTION
D
FEATURES
AMCA certified performance

Permatector coating

Cast aluminum airfoil

propeller
B
Fabricated steel propeller

Polished steel shaft

C
Heavy gauge curb cap,
tubular housing, and

windband
Steel or aluminum butterfly

2 / in.
backdraft dampers
A
Adjustable
motor plate

Corrosion resistant

fasteners
Cast iron pillow block
TUBE AXIAL PERFORMANCE

bearings
TAUD performance capabilities are
Extended
lube lines

2,800 to 46,000 cfm and up to 1 in.


wg of static pressure. TAUB-L/H
Minimum bearing life L(10)

performance capabilities are 5,000


40,000 hrs
to 60,000 cfm and up to 1 in. wg of
static pressure. TAUB-CA performance
capabilities are 3,000 to 74,000 cfm and
up to 1 in. wg of static pressure.
1

TAUD STANDARD CONDENSED PERFORMANCE


& DIMENSIONAL DATA
MODEL

ROOF
OPENING

TAUD-18

26

46

22

25

20 x 20

TAUD-20

30

46

23

27

22 x 22

TAUD-24

34

52

257/8

307/8

26 x 26

40

577/8

285/8

371/8

TAUD-30

TAUD-36

TAUD-42

TAUD-48

46

62

31

43

52

697/8

33

495/8

58

753/8

375/8

55

32 x 32

38 x 38

44 x 44

50 x 50

MIN/MAX
RPM

1140
1725
1140
1725
860
1140
1725
860
1140
1725
860
1140
1725
680
860
1140
680
860
1140

3221
4584
4448
5568
5090
7383
10695
10898
13691
18144
19008
22914
29680
21959
25086
36814
30936
36360
46455

PERFORMANCE IN INCHES WG
.125
.25
.5
.75
2739
4348
3989
5267
4038
6740
10288
9636
12762
17485
17401
21960
28872
19186
23024
35197
27426
33983
44268

4108

3536

4926

4187

6072
9901
8215
11812
16789
15604
20736
28042
15981
20771
33468
23440
31147
42243

9073

8095

7603

9695
15137

13450

11405

18177
26197

14977
24193

22056

14921
30373

25503

24197
38672

32978

26099

All dimensions in inches.


Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances
(accessories).

Greenheck Fan Corporation certifies that


the TAUD and TAUB-CA models shown
herein are licensed to bear the AMCA Seal.
The ratings shown are based on tests and
procedures performed in accordance with
AMCA Publication 211 and comply with
the requirements of the AMCA Certified
Ratings Program.

UL/cUL 705
E40001 TAUD/TAUB

UL Listed Power Ventilators


for Smoke Control Systems
(TAUB-L/H)

Greenheck Fan Corporation certifies that


the TAUB-L/H only models shown herein are
licensed to bear the AMCA Seal. The ratings
shown are based on tests and procedures
performed in accordance with AMCA
Publication 211 and AMCA Publication 311
and comply with the requirements of the
AMCA Certified Ratings Program.

FANS

77

WxL
(Width x Length)

A sq.

WxL
(Width x Length)

Tall Base Option

A sq.

Reversible Fabra Fans - RPDR/RPBR


STANDARD CONSTRUCTION FEATURES

OPTIONS AND ACCESSORIES

Washable aluminum filters


Base and hoods of galvanized steel
Galvanized wire mesh birdscreen
Double venturi
Reversible cast aluminum airfoil blade propeller
Protective guards
Ball bearing motors
Adjustable motor plate
Adjustable motor pulley
Fan shaft mounted in ball bearing pillow blocks
Static resistant belts
Corrosion resistant fasteners
Tie down points.
(Due to shipping size limitations, hoods for fans
sizes 48 and larger will be shipped in sections.
Hood assembly requires no special tools or training.
Complete illustrated assembly and installation
instructions are packed with each fan.)

Filtered fan with 2 in. filters


Aluminum housing
Tall bases
Motorized dampers
Galvanized roof curbs (See pages 114-115)
Aluminum roof curbs (See pages 114-115)
Insect screen bases
Rubber curb cap stripping
Curb adaptors
Extended lube lines (Belt Drive)
Tie down points
Dual drives
Hood insulation
Greenheck coatings (See coatings page 117)

RPBR STANDARD CONDENSED PERFORMANCE & DIMENSIONAL DATA CAST ALUMINUM PROPELLER
MODEL

RPBR-24

RPBR-30

RPBR-36

RPBR-42

RPBR-48

CFM
RANGE
@ .25 SP

2866-7679

7070-14022

9150-20183

8993-25002

7338-32532

RPBR-54 12437-41542

RPBR-60 14113-43965

RPBR-72 22926-63816

34

40

46

52

58

64

70

82

32

34

38

43

44

49

50

53

WxL
(STANDARD
HOOD)

66 x 63

74 x 75

76 x 87

86 x 99

100 x 111

112 x 111

124 x 123

136 x 135

All dimensions in inches.

For complete product information


refer to catalog Reversible
Fabra Fan, or contact your local
representative.
80

FANS

WxL
(FILTERED
HOOD)

66 x 63

78 x 87

94 x 87

100 x 99

112 x 111

124 x 123

136 x 135

136 x 147

ROOF
OPENING

26 x 26

32 x 32

38 x 38

44 x 44

50 x 50

56 x 56

62 x 62

74 x 74

MIN/
SONES
MID/MAX
@ .125 in.
RPM

PERFORMANCE IN INCHES WG
0

.125

.25

.375

.5

850

19.7

4457

3268

1295

33

6790

6241

5341

4220

1635

48

8573

8155

7679

6911

6023

650

17.6

6943

1000

36

10682

9609

7900

1450

62

15488

14813

14022

13125

11850

17887

625

20

9601

6731

1040

46

15977

14955

13411

1415

79

21738

21020

20183

19080

500

20

11888

6713

875

46

20804

18756

15948

11888

1180

74

28056

26551

25002

22725

480

23

15116

9862

805

49

25352

23210

20632

15240

1130

87

35587

34108

32532

30813

28809

400

22

21919

16285

645

47

35344

32897

28341

24563

21011

830

73

45481

43760

41542

38359

34545

440

27

26801

20934

14113

630

48

38374

35116

30228

25640

20748

805

80

49034

46568

43965

40611

36071

340

24

34031

20399

555

56

55551

51205

44148

28723

705

86

70565

67077

63816

58014

20602

45700

Outlet
Vetrtical Air Flow
Option

G
F

Filter
Projection
2 or 4 in.

D
E
Inlet
Air Flow
B

Modular Small Cabinet Fan - MSCF


Mixing Box

Plenum

Filter

Heating

Cooling

Fan

G
A

MSCF DIMENSIONAL DATA


A
w/o
w/ Filter
Filter
11
24.5
14
24.5
16
27
18.5
31
18.5
32
21
32
26
38
26
38

Unit
Size
15
20
25
30
45
50
65
85

12 in.

24 in.

Vertical

Sloped

12.75
12.75
12.75
12.75
12.75
12.75
12.75
12.75

24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5

12.75
12.75
12.75
12.75
12.75
12.75
12.75
12.75

24.5
24.5
27
31
32
32
38
38

Hot Water
1 & 2 Row
12.75
12.75
12.75
12.75
12.75
12.75
12.75
12.75

Inlet
4 Row HW &
Steam
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5

Unit

24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5

25
25
29
32
32
38
42
42

11
14
16
18.5
18.5
21
26
26

38
38
38
38
50
50
50
62

Outlet

Height

Width

Height

Width

9
12
14
16.5
16.5
19
24
24

36
36
36
36
48
48
48
60

4
6.5
8
9
9
10.25
12
12

6.75
6.75
8.5
9
10
10
12.75
15

All dimensions are in inches. For complete dimensional information, see CAPS submittal drawings.

Low Profile Fan Coil - LFC


LFC DIMENSIONAL DATA
Unit
Size

w/o
Filter

A
w/ 2 in.
Filter

w/ 4 in.
Filter

Width

40
40
40
45
45
48
52
52

42
42
42
47
47
50
54
54

44
44
44
49
49
52
56
56

11.0
14.0
16.0
18.5
18.5
21.0
26.0
26.0

38
38
38
38
50
50
50
62

15
20
25
30
45
50
65
85

Inlet

Outlet

Height Width Height


9.0
12.0
14.0
16.5
16.5
19.0
24.0
24.0

36
36
36
36
48
48
48
60

4.0
6.5
8.0
9.0
9.0
10.25
12.0
12.0

Width
6.75
6.75
8.5
9.0
10.0
10.0
12.75
15.0

All dimensions are shown in inches.

MSCF/LFC PERFORMANCE DATA


UNIT SIZE

15

20

25

30

45

50

65

85

NOMINAL CFM

800

1100

1350

1600

2250

2600

3350

4300

FAN/MOTOR DATA
RPM Range

1100 - 3500

1100 - 3500

800 - 3050

750 - 2500

725 - 2400

650 - 2200

500 - 2000

500 - 2200

HP Range

.25 - 2

.25 - 2

.25 - 3

.25 - 3

.25 - 3

.25 - 5

.25 - 7.5

.25 - 10

Max. BHP

2.1

2.1

2.1

3.15

3.15

5.25

7.875

10.5

300 - 800

600 - 1100

900 - 1800

1200 - 2400

1500 - 2900

1800 - 3600

2400 - 4200

3000 - 5800

2 - 9 x 18

2 - 14 x 18

2 - 16 x 24

2 - 18 x 24

2 - 24 x 24

3.0

1 - 16 x 16
1 - 16 x 20
3.4

4.8

5.4

7.2

1 - 12 x 24
2 - 24 x 24
8.9

450

471

469

481

465

483

2 - 24 x 24

2 - 24x24

4 - 24x24

CFM Range
VERTICAL FILTER DATA

Area - ft

1.8

1 - 12 x 12
1 - 12 x 24
2.5

Velocity - ft/min.

444

440

Qty. & Size - in. (cm)

^ SLOPED FILTER DATA


Qty. & Size - in.

1 - 12 x 12

1 - 16 x 16

1 - 12 x 24

1 - 16 x 20

2 - 16 x 20

1 - 12 x 24
1 - 24 x 24

2 - 12 x 24
4 - 24 x 24

Area - ft2

2.5

3.4

3.8

5.3

7.2

7.2

14.4

17.8

Velocity - ft/min.

320

324

355

302

313

361

233

242

COIL DATA
Area - ft2

1.6

2.2

2.7

3.2

4.5

5.2

6.7

8.6

Width - in.

7.50

10.00

12.50

15.00

15.00

17.50

22.50

22.50

Length - in.

31.00

31.00

31.00

31.00

43.00

43.00

43.00

55.00

500

500

500

500

500

500

500

500

Velocity- ft/min.

^ Available for MSCF unit only. For complete performance information see CAPS.

For more product information refer


to Catalog Indoor Air Handling
Units, or contact your local
representative.
TEMPERED FANS

85

Direct Fire Gas - Models DGK, DG & DGX

Equally important, Greenheck combination packages are specifically designed to


comply with NFPA 96.
A max.
10 ft. min.

DG
Dimensions

The Greenheck combination kitchen package simplifies installation and reduces


field labor costs. The pre-engineered design ensures that the supply fan, exhaust
fan, curb and combination extension components interface properly.

DGX
Dimensions

COMBINATION PACKAGES - DG & DGX


ARR. DBC

Housing
Size

Width

H10

179

46

30

H20

200

54

40

H30

225

62

52

ARR. DBC

Housing
Size

Width

H12

171

46

33

H22

225

54

44

H32

261

62

52

All dimensions are in inches.

Downblast Discharge - Arrangement DB

DGK
Dimensions

Model DGK, DG and DGX are available for either downblast (Arrangement DB) or
horizontal (Arrangement HZ) discharge. An upblast discharge (Arrangement UB) is
also available on the DGX.

Housing
Size

Width

H15

108

30

32

Housing
Size

Width

H10

131

34

28

H20

148

34

36

H30

160

42

48

DGX
Dimensions

STAND ALONE ARRANGEMENTS - DGK, DG & DGX

DG
Dimensions

Combination Package - Arrangement DBC


ARR. DB/HZ

ARR. DB/HZ

ARR. DB/HZ

Housing
Size

Width

H12

127

40

33

H22

160

46

44

H32

1920

49

52

All dimensions are in inches.

THRU-WALL INSTALLATION - DGX


Model DGX is available with a pre-engineered, thru-wall installation option, which
is ideal when a roof penetration is not desirable.
Factory options that facilitate easy installation and ensure problem-free
operation:
Weatherhood: A full down turn design with generous intake area to minimize
intake velocity and moisture entrainment.

DGX
Dimensions

Horizontal Discharge - Arrangement HZ


Housing
Size

THRU WALL MOUNT


A

Width

H12

122

40

33

H22

145

46

36

H32

160

49

52

All dimensions are in inches.

Thru-Wall Sleeve: Sleeve provides attachment interface between weatherhood


and burner section. Accommodates walls up to 15 inches in depth.
Filter Section: Aluminum mesh media filters outdoor air and strips fine mist from
the air. A drain pan weeps moisture out the front of the wall sleeve.

Consult your representative


for dimensional data when
the evaporative cooling option
is selected. For roof opening
dimensions and locations refer to
the factory submittal.
Thru Wall Arrangement

TEMPERED FANS

87

IG Dimensional Data
B

A max
10 ft.
min

36 in.

B max

Combination Package - Arrangement DBC

Stand Alone - Arrangement DB/HZ


ARR. DB/HZ

ARR. DBC

Housing
Size

Width

Housing
Size

Width

H10

90

26

44

H10

182

56

48

H20

93

26

53

H20

183

56

53

H30

102

26

53

H30

181

56

53

Dimensions are in inches and


include mixing box and standard
weatherhood. For roof opening
dimensions and locations refer to
factory submittal.

Dimensions are in inches.

For roof opening locations refer to


factory submittal/IOM. Consult your
representative for dimensional data
when the evaporative cooling option is
selected.

IGX Dimensional Data

10 ft.
min.

Stand Alone - Arrangement DB/HZ


ARR. DB/HZ

Combination Package - Arrangement DBC


ARR. DBC

Housing
Size

Width

Housing
Size

H12

122

40

33+

H12

H22

140*

46

44

H22

H32

173*

49

52

H32

242*

Width

166

46

33+

206*

54

44

62

52

All dimensions are in inches.


* A dimension for units with only one furnace.
Add 33 in. for each additional furnace.
+ Furnace section width is 44 in. for 200 MBH and 250 MBH
furnace sizes.

Indirect Fired
Gas Heat

Consult your representative


for dimensional data when the
evaporative cooling option is
selected.
TEMPERED FANS

89

B
B
C

C
D

D
Dia.
A

13/4 in.

Dia.
A

13/4 in.

7/8

in.

2 in.
C
5 in.
Throat Width
Curb Cap Width
B

Throat Length
Curb Cap Length

21/2 in.

Outdoor Air
Discharge
B

A
D

E
Exhaust
Air Inlet

Intake Hood
Exhaust Hood

Outdoor Air
91F

Preconditioned Outdoor Air


79F
Energy
Recovery
Ventilator

Exhaust Air
87F

Supply
55F

AHU

Exhaust Air
75F
Return Air
75F

Laboratory Exhaust Systems

Family
of Lab
Exhaust
Systems
Vektor-MD

Vektor-H

Vektor-H

Vektor-CD

Vektor-MD

Vektor-CD

Housing Style

Inline Centrifugal

Inline Mixed Flow

Centrifugal

Stack Style

High Plume Nozzle

High Plume Dilution Nozzle

High Plume Dilution Nozzle

Min Flow

500 CFM {850 m3/hr}

1,500 CFM {2,550 m3/hr}

500 CFM {850 m3/hr}

Max Flow

24,000 CFM {40,750 m3/hr}

80,000 CFM {135,900 m3/hr}

100,000 CFM {170,000 m3/hr}

Max ESP

Up to 3.5 inches wg {875 Pa}

Up to 8 inches wg {2000 Pa}

Up to 14 inches wg {3500 Pa}

Why use Greenheck Vektor Lab Exhaust Systems?


The main objective of a laboratory exhaust system is to remove hazardous or noxious fumes from a laboratory, dilute the
fumes as much as possible and expel them from the lab building so that the fumes do not contaminate the roof area nor are
re-entrained into the building makeup air system.
Greenheck Vektor laboratory exhaust systems offer the following benefits:
Significant plume rise without unsightly exhaust stacks
that detract from buildings aesthetics
Significant dilution of laboratory exhaust effluent,
reducing contaminant concentration
Inline or side inlet centrifugal arrangements
Reliable belt or direct drive systems
Efficient and quiet blower technology
AMCA class C or B spark resistant construction
Premium high efficiency motor, standard
Application to constant or variable volume exhaust
systems
Efficient discharge nozzle design
Corrosion resistant baked polyester resin coating

Safe and easy maintenance


Multiple fan assemblies
on a factory provided
common plenum
Meets ANSI Z9.5 and
ASHRAE lab design
guidelines
Energy Recovery options
available
Designed and
guaranteed to withstand
125 mph windloads
without the use of guide
wires

How Vektor High Plume Dilution Technology Works...


Laboratory exhaust is drawn into the Vektor fan (A). The exhaust is discharged into the
Vektor multi-stage induction nozzle and ambient dilution air is induced into the Vektor
windband (B). The laboratory exhaust plus induced dilution air is discharged at high
velocity to atmosphere (C). Available on the Vektor-MD and Vektor-CD.
94

LABORATORY EXHAUST SYSTEMS

Isolation Damper
Bypass Air
Damper

Bypass Air
Plenum

Bypass Air
Laboratory
Exhaust

Mixed Flow Wheel

Vektor Housing

Isolation Damper

Bypass Air Damper

Bypass Air
Lab Exhaust Air

Flex Connection

Lab Exhaust Air


(Horizontal Intake)

Bypass Air

Lab Exhaust Air


(Vertical Intake)

Type A

Type B*

Type C*

Blades In Airstream

Blades Out Of
Airstream
st ea

100% Free Area

Type CO*

Type CR*

Type R*

100% Free Area

100% Free Area

High Free Area

Steel Stud
Frame

Wallboar d

Retaining
Bar

Cross-Section A-A

Damper
Sleeve

Fire Smoke Dampers

MODEL FSD: Traditional Fire Smoke


Classified to UL/cUL 555 and UL/cUL 555S and must be mounted
within the plane of the wall or floor. Rated for airflow and leakage in
either direction.

Performance
Performance capabilities up to 3000 fpm and 4 in. wg of static pressure.

MODEL OFSD: Out Of Wall Fire Smoke


Classified to UL/cUL 555 and UL/cUL 555S and can be installed outside
of the plane of the wall or floor. This allows the actuator to be mounted
internally with convenient access to the damper, actuator, and heat
responsive device through the grille. The entire installation can be done
from the grille side of the opening. Rated for airflow and leakage in
either direction.

Performance
Performance capabilities up to 3000 fpm and 4 in. wg of static pressure.

MODEL CFSD: Corridor Fire Smoke


Models each with three mounting configurations available.
1-hour Corridor Fire Resistance Rating and UL/cUL 555S Leakage
Rating. Can be installed horizontally behind grilles and diffusers in
corridor penetrations with ratings for airflow and leakage in either
direction.

Performance
Performance capabilities up to 2000 fpm and 4 in. wg of static pressure.

TRANSITION TYPES

AIRFOIL

RRL - Standard
(Standard on QD Stock Models)

Thermostat

3V
Type O
100% Free Area

Type R
100% Free Area

Type C
100% Free Area

Greenheck Fan Corporation certifies that the FSD211, 212, 213, 231, 311, 311M, CFSD-211, 212,
OFSD-211, 212, 311, 312, SSFSD-211, SEFSD211 models shown herein are licensed to bear
the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
with AMCA Publication 511 and comply with the
requirements of the AMCA Certified Programs.

100

DAMPERS

TOR

High Te mp. Sensor


Primary
Sensor

OCI

Ceiling Radiation
Damper
Thermal
Blanket
3 3/4" Max.

Lay-In Diffuser

Tee Bar

Stand off Bracket

Manual Hand Quadrant

Extended Pin

Non-Drainable
Head

K Blade

J Blade

Sloped Sill

Non-Drainable
Head

2 in.
4 in.
6 in.

Sloped Sill
4 in.
6 in.

Drainable
Head

Drainable
Head

Drainable
Head

Exhaust
Blade
K Blade

Separator
Plate

J Blade

Sloped
Sill

2 in.
4 in.
6 in.

Sloped
Sill
4 in. / 6 in.

Sloped
Sill
4 in.

Drainable
Head

Flat Head
Drainable
Head

Drainable
Head

Line of

Dual
Drainable
Blade

Sloped
Sill

Sloped
Sill

2 in.
4 in.
6 in.

Flat Sill
Sill Pan
4 in. / 6 in.

Hidden Mullion

Dual
Drainable
Blade

Drainable
Blade

6 in.

Frame

Frame

Frame

Support
Strut

Blade

Blade

Blade
Blade

Support
Strut

Frame

Frame
1.5 in.

1.375 in.

Frame
1.5 in.

1.5 in.

Sightproof
Head

Drainable
Sightproof
Head

Sightproof
Blade

Drainable
Sightproof
Blade

Flat Sill

Flat Sill

2 in.
4 in.

2 in.
4 in.

Drainable
Sightproof
Head

Drainable
Sightproof
Head

Sightproof
Blade

Drainable
Sightproof
Blade

Flat Sill

Flat Sill
5 in.

2 in.
4 in.

Drainable
Head

Drainable
Head

Top Stop

Top Stop

Drainable
Adjustable Blade

Drainable
Blade
Bottom
Stop
Concealed
Actuator
Location
Flat Sill

Bottom Stop
Flat Sill
4 in.
6 in.

Drainable
Head

4 in.
6 in.

Head Member

Top Stop
Adjustable
Blade
Adjustable Blade

Bottom Stop
Flat Sill

Flat Sill
4 in.

6 in.

Flat
Head

Drainable
Head

Blade
Linkage

Top
Stop

Fixed
Blade

Movable
Blade
Fixed
Blade

Movable
Blade
Bottom
Stop
Flat Sill

Flat Sill

4 in.
6 in.

4 in.
6 in.

6 in.

Formed
Head
Member

Formed
Blade
Member

Bottom
Stop
Formed
Sill Member
4 in. / 6 in.
Formed
Head
Member

Formed
Head
Member
Formed
Fixed Blade

Formed
Blade
Member
Bottom
Stop
Formed
Sill Member
4 in. / 6 in.

Formed
Adjustable
Blade
Stainless
Steel
Jamb Seal
Bottom
Stop
Formed
Sill Member

4 in. / 6 in.

4 in.
5 in.
6 in.
7 in.
Drainable
Head

Rain
Resistant
Blade

4 in.
6 in.
8 in.

High
Performance
Jamb
High Performance
Blade

Flat Sill
Formed Sill Pan

Formed
Head Member
Fiberglass
Insulation

Insulation
Screen
Formed
Acoustical Blade

Formed
Sill Member

Bottom
Blank Off
8 in.

Formed
Head Member

Formed
Acoustical Head
Fiberglass
Insulation
Formed
Acoustical Blade

Insulation
Screen

Fiberglass
Insulation

Formed
Blade Member

Insulation
Screen
Formed
Acoustical Sill

Formed
Sill Member
6 in.
8 in.
12 in.

12 in.

Throat
A
Curb Cap

Options and Accessories


Mounting Options
The mounting options shown on this page (type A and B) relate to the Selection Guide For Vibration Isolation as published in
the latest ASHRAE applications handbook, HVAC Applications-Sound and Vibration Control.

DIRECT MOUNT - TYPE A


No base required. Isolators are attached directly to
equipment. Direct isolation can be used if equipment
is unitary and rigid without the use of additional
support. Direct isolation is not recommended for
equipment having large overhung loads (e.g. motors
on Arr. 9 fans). If there is any doubt that equipment
can be supported directly on isolators, use rails,
bases or consult the factory.

Spring

Rubber

STRUCTURAL BASES - TYPE B2


Structural steel bases consist of structural steel
members welded into a rigid one piece base. Motor
slide rails are included where applicable. Bases are
required for all Arr. 1 and 3 fans with independently
mounted motors. Structural steel bases are available
without isolators, with rubber mounts or with spring
mounts. All structural steel bases with spring mounts
incorporate height saving brackets.

Rubber Mount
Shown W/O
Isolators or
Brackets

Quick Build bases are standard dimensions with factory supplied


motor and drives.

Spring Mount
W/Height Saving Bracket

RESTRAINED SPRING MOUNTS - TYPE 4A 1


in. DEFLECTION

RUBBER MOUNTS - TYPE 2


1/4 in. & 1/2 in. DEFLECTION

Restrained spring isolators consist of laterally stable, freestanding springs assembled into a steel housing. These
assemblies are designed for vertical and horizontal motion
restraint. Restrained spring isolators can be used for
blocking during equipment installation and are provided
with leveling bolts. Springs provide 50% overload capacity
and are color coded or identified to indicate load capacity.
Restrained spring mounts are recommended for equipment
subject to wind loading or large torquing forces.

Neoprene mountings consist of a steel


top plate and base plate completely
embedded in colored (oil-resistant)
neoprene for easy identification of
capacity. Neoprene mountings are
furnished with a tapped hole in the
center. This enables the equipment to
be bolted securely to the rubber mount.

FREE-STANDING OPEN
SPRING MOUNTS TYPE 3
1 in. DEFLECTION

HOUSED SPRING MOUNTS - TYPE 4B


1 in. DEFLECTION

Free-standing spring isolators are


unhoused laterally stable steel springs.
They provide a minimum horizontal
stiffness of 0.8 times the rated vertical
stiffness and provide an additional 50%
overload capacity. These isolators are
equipped with a top mounted adjusting bolt
and an acoustical non-skid base. Springs
are color coded or identified to indicate
load capacity.

Housed spring isolators consist of steel springs assembled


into a telescoping housing with a top mounted adjusting
bolt and an acoustical non-skid base. Housed spring
isolators include resilient inserts to prevent metal-to-metal
contact and provide snubbing for side loads. Springs
provide an additional 50% overload capacity and are color
coded or identified to indicate load capacity.

MOUNTING SELECTION
ARR
1
3
4
9
10

116

OPTIONS AND ACCESSORIES

FAN TYPE
AF/BISW
IPA/O/W
AF/BISW
AF/BIDW
SFD
AF/BISW
IPA/O/W
SFB/SWB
AF/BISW
AF/BISW
IPA/O/W

DIRECT MOUNT
(TYPE A)

X
X
X
X
X

STRUCTURAL BASE
(TYPE B2)
X
X
X
X
X
X
X
X
X

Coatings
Greenheck now offers a choice of either protective or decorative coatings for many
of the Quick Build products.
Protective coatings are available in a choice of four electrostatic applied powders.
Powders available range from polyester urethanes to high performance epoxy
providing an available selection for most environments.
Powder coatings offer a number of advantages over most wet coatings. Electrostatic
painting involves applying a dry, charged particle to a grounded sheet metal. The
results are uniform coverage and thickness with heavier coverage in the high charge
areas (edges, corners, and pockets), that are difficult to reach with wet paint. Another
advantage is environmental friendliness.

PERFORMANCE COATINGS
The following is a brief description of the protective coatings offered. Complete
descriptions and protective qualities can be found in GREENHECKS SPECIAL
COATING ENGINEERING BULLETIN (or consult your local representative).
Each protective coating has a distinctive color for identification.

POWDER COATINGS
PERMATECTOR

Hi-Pro Polyester

Hi-Pro Polyester*

Permatector

Decorative Coatings

Permatector is the standard coating applied to all steel fans.


Typical applications include corrosion resistance in indoor and
outdoor environments.

For projects where the fan exterior


appearance is important and additional
chemical resistance is not required,
customers can choose from 16 standard
decorative colors.

Hi-Pro Polyester (Used in lieu of Air Dry Phenolic)


This coating is resistant to salt water, chemical fumes, and moisture
in more corrosive atmospheres. It has superior chemical resistance,
excellent abrasion and outdoor UV protection. This coating
has protective qualities that exceed Air Dried Heresite.
*Note: Standard Hi-Pro Polyester Lab Exhaust products are 041 gray

EPOXY

INDUSTRIAL
EPOXY

Epoxy
Epoxy has excellent moisture resistance and moderate to good
chemical resistance. Greenhecks epoxy is light tan in color so it
will resist fading and chalking when exposed to sunlight.

Heat Cured Enamels


Decorative coatings are heat cured enamels
applied either as wet paints or electrostatic
powders.
The range of colors offered provides for
a color selection to meet most exterior
requirements.

Industrial Epoxy
Industrial Epoxy is a high performance epoxy with excellent
chemical resistance in interior applications to a wide variety of
chemicals including acids, caustics, solvents, and high moisture.
MARBLE
IVORY

SPARTAN
WHITE

NOTE: Colors are subject to change.

GRAY
COLONIAL
BLUE

DESERT
SAND
BEECHNUT

HORIZON
BLUE

TAUPE

MEDIUM
BRONZE

STATUARY
BRONZE

NOTE:
Colors are subject to change.

LIGHT
GRAY
CHARCOAL

MACHINE
TOOL
GRAY

FLAT
BLACK

GLOSS
BLACK

OPTIONS AND ACCESSORIES

117

Fan Fundamentals
Introduction to FAN SELECTION
This is a guide to the most basic fan sections, all of which enable you to select the right fan for the job. It will answer the
following questions (and more):
What is a SONE?
How are model numbers and performance tables used to select a fan?
How are direct drive and belt driven fans different?
What types of motors are used with these fans?
The goal is to understand and use the Greenheck literature as an important tool in filling a customers fan order.

TERMS
cfm
Ps
sone
Bhp
hp

Cubic Feet Per Minute. A measure of airflow.


Static Pressure. Resistance to airflow measured in inches of water gauge.
A measure of loudness. One sone can be approximated as the loudness of a quiet refrigerator at a distance of 5
feet. Sones follow a linear scale, that is, 10 sones are twice as loud as 5 sones.
Brake Horsepower. A measure of power consumption. Used to determine the proper motor horsepower and wiring.
Horsepower. Used to indicate a fans motor size.

rpm
TS

Revolutions Per Minute. Measure of fan speed.


Tip Speed. The speed of the tip of a fan wheel or prop measured in feet per minute.
AMCA Air Movement & Control Association. A nationally recognized association which establishes standards for fan testing and
performance ratings. AMCA also license air volume and sound certified ratings.

MODEL DESIGNATION
For Greenheck belt drive models, the model designation tells the model type, size and the motor hp.
EXAMPLE:

GB-090-6

Model is GB
hp is 1/6
Nominal Wheel Dia. 9 in.

For direct drive units, the model designation tells


the model type, the size and the motor/fan rpm.
EXAMPLE:

G-121-B

Model is G
rpm is 1140
Nominal Wheel Dia. 12 in.

MOTOR INFORMATION (Belt Drive Only)


When specifying a belt drive fan, the model designation
does not completely describe the unit. Additional
information about the motor is necessary. These items
are listed below:
MOTOR ENCLOSURE
This will be either Open (open, drip proof), TE (totally
enclosed) or EXP (explosion resistant). Open is the
most common and will be supplied unless otherwise
specified.

BELT DRIVE
Sufx
Motor hp
1/6
6
4

1/3
3
5

10
1
15
1
20
2
30
3
50
5
75
7

DIRECT DRIVE
Sufx
Fan rpm
A
1725
B
1140
C
860
D
1550
G
1300
E
1050
F
880
P
1625

This table lists model


designation suffixes for
motor horsepower and
fan rpm.

SPEEDS
Motors are available in either single speed or two speed.
Single speed motors are 1725 rpm. Two speed motors
will be 1725/1140 rpm. Single speed will be supplied
unless otherwise specified.
ELECTRICAL CHARACTERISTICS
Voltage and phase. Voltage can be 115, 208, 230 or 460.
Phase is either single or 3 phase. A 115 volt, single phase
motor is shown as 115/1. Typically, motors of 1/2 hp and
less are single phase. Motors of 3/4 hp and greater are 3
phase.

DIRECT DRIVE
Selection of direct drive fans (those with the motor shaft
connected to the fan wheel or propeller) is nearly the
same as belt drive selection. However, there are two
differences worth noting. Where belt drive fan speed can
be altered by adjusting the motor pulley, direct drive fans
(since they have no pulleys) must use a different method.
1 To adjust a direct drive fans speed (also motor speed)
or to provide a means of meeting an exact performance
requirement, a speed control can be furnished. Speed
controls vary the voltage supplied to the fan and slow
it down; a principle similar to the way dimmer light
switches work.
2 Models CUE and CW, sizes 060-095 and Model SQ,
sizes 60-95, are provided with 115 volt, 60 cycle motors.

TYPICAL MOTOR TAG Suffix Letter Motor Speed


D
1550 rpm
G
1300 rpm
E
1050 rpm

Electrical Instructions
Wiring Connections
White to L1 Black to L2
White to L1 Blue to L2
White to L1 Red to L2

The three speeds are 1550 rpm (D), 1300 rpm (G) and 1050
rpm (E). Changing a motor lead is all that is necessary to
change speeds. When selecting a model with a 3 speed
motor, it is recommended that the G speed be chosen
whenever possible. This is the middle speed, which gives
the greatest flexibility in air volume because airflow can be
increased or decreased simply by changing a motor lead.
FAN FUNDAMENTALS

119

Introduction to FAN SELECTION


MOTOR HORSEPOWER
The motor horsepower for direct drive fans is
always sized by Greenheck and does not require
further consideration. For belt drive models,
the catalog identifies which horsepower is
recommended. However, there are times when it
is wise to bump the horsepower one size. For
example, the hp recommended for the GB-180
at 810 rpm (2375 cfm @ .5 Ps, page reference
9) is 1/3 hp.
Although a 1/3 hp motor is recommended, it is
not necessarily a good motor selection for this
application. Our static pressure of 0.5 in. was only
an estimate. It may actually turn out to be .625 in.

If this is the case, we will need a 1/2 hp motor


because our fan will have to run at almost
810 rpm (refer to performance box - 2052 cfm
at 0.625 in. Ps, page reference 9). Therefore,
choosing a 1/2 hp motor in this case is exercising
good judgement.
The complete model designation for this
application is GB-180-5.
NOTE: The GB-180-5 has an rpm range of 700-940.
This means that if the static pressure is less than
estimated, say 0.25 in. Ps, the fan can be slowed down
to accommodate this condition.

BELT DRIVE
One advantage of choosing a belt drive over a direct
drive is that it is capable of adjusting the fan rpm,
which enables the fan to move more air if necessary.
Motor pulleys are adjusted by loosening the set
screw and turning the top half of the pulley (see
illustrations at right). This causes the pulley diameter
to change, which results in changing the fan rpm.

APPLICATIONS
Ventilating a building simply replaces stale or foul
air with clean, fresh air. Although the ventilation
process is required for many different applications,
the airflow fundamentals never change:
UNDESIRED AIR OUT, FRESH AIR IN
The key variables that do change depending on
applications are the fan model and the air volume
flow rate (cfm). Other considerations include the
resistance to airflow (static pressure or Ps) and
sound produced by the fan (Sones).
Occasionally, a customer will require a fan to perform
a particular function, yet does not know which model
to use or even what cfm is necessary. In this case,
some fan specification work must be done.
Fan specification is usually not a precise science
and can be done confidently when the fan
application is understood.
Based on the application, four parameters need to
be determined. They are:
Fan Model
Cubic Feet per Minute (cfm)
Static Pressure (Ps)
Loudness limit (sones)

120

FAN FUNDAMENTALS

Belt
Opening the pulley decreases fan rpm.
Closing the pulley increases fan rpm.

The information that follows will help walk you


through this type of problem and enable you to
select the right fan for the job.

FAN MODEL
Fans all perform the basic function of moving
air from one space to another. But the great
diversity of fan applications creates the need for
manufacturers to develop many different models.
Each model has benefits for certain applications,
providing the most economical means of performing
the air movement function. The trick for most users
is sorting through all of the models available to find
one that is suitable for their needs.

PROPELLER vs. CENTRIFUGAL WHEEL


Propeller fans provide an economical method to
move large air volumes (5,000+ cfm) at low static
pressures (0.50 in. or less). Motors are typically
mounted in the airstream which limits applications
to relatively clean air at maximum temperatures of
110F.
Centrifugal fans are more efficient at higher static
pressures and are quieter than propeller fans.
Many centrifugal fan models are designed with
motors mounted out of the airstream to ventilate
contaminated and high temperature air.

Introduction to FAN SELECTION


DETERMINING CFM
After the model is known, the cfm must be determined.
Consult local code requirements or the table below for
suggested air changes for proper ventilation.

location and average duty level of the area. For hot


climates and heavier than normal area usage, select
a lower number in the range to change the air more
quickly. For moderate climates with lighter usages,
select a higher number in the range.

The ranges specified will adequately ventilate the


corresponding areas in most cases. However, extreme
conditions may require Minutes per Change outside
of the specified range. To determine the actual number
needed within a range, consider the geographic

To determine the cfm required to adequately ventilate


an area, divide the room volume by the appropriate
Minutes per Change value.

SUGGESTED AIR CHANGES FOR PROPER VENTILATION


cfm = Room Volume
Min./Chg.
Area
Assembly Hall .
Attic . . . . . . .
Auditorium . . .
Bakery . . . . . .
Bar . . . . . . . .
Barn . . . . . . .
Boiler Room . .
Bowling Alley .
Cafeteria . . . .
Church . . . . .
Classroom . . .
Club Room . . .

.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.

Min./Chg.
. . . . 3-10
. . . . . 2-4
. . . . 3-10
. . . . . 2-3
. . . . . 2-4
. . . 12-18
. . . . . 1-3
. . . . . 3-7
. . . . . 3-5
. . . . 4-10
. . . . . 4-6
. . . . . 3-7

Area
Dance Hall . . . . .
Dining Room . . .
Dry Cleaner . . . .
Engine Room . . .
Factory . . . . . . .
Foundry . . . . . . .
Garage . . . . . . .
Generator Room .
Gymnasium . . . .
Kitchen . . . . . . .
Laboratory . . . . .
Laundry . . . . . . .

SAMPLE PROBLEM
A building requires an exhaust fan to ventilate a
general office (see diagram below) which measures 30
ft. x 40 ft. x 8 ft. The office is often crowded.
SOLUTION:
The total room volume is 30 ft. x 40 ft. x 8 ft. = 9600
cubic feet. From the chart, the range for general
offices is 2-8 minutes per change. Since the office has
heavier than normal usage, 4 minutes per change is
recommended. Therefore, the required exhaust is:

Room Volume = L x W x H (of room)

.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.

Min./Chg.
. . . . .3-7
. . . . .4-8
. . . . .2-5
. . . . .1-3
. . . . .2-7
. . . . .1-5
. . . . 2-10
. . . . .2-5
. . . . .3-8
. . . . .1-5
. . . . .2-5
. . . . .2-4

Area
Machine Shop . . .
Mill . . . . . . . . . . .
Office . . . . . . . . .
Packing House . .
Projection Room .
Recreation Room .
Residence . . . . . .
Restaurant . . . . .
Rest Room . . . . .
Store . . . . . . . . .
Transfer Room . . .
Warehouse . . . . .

.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.

Min./Chg.
. . . . . 3-6
. . . . . 3-8
. . . . . 2-8
. . . . . 2-5
. . . . . 1-2
. . . . . 2-8
. . . . . 2-6
. . . . 5-10
. . . . . 5-7
. . . . . 3-7
. . . . . 1-5
. . . . 3-10

Since the air to be exhausted is relatively clean, this is


an ideal application for a model GB fan.
NOTE: In this example, make-up air was provided
through a set of louvers at the wall farthest from the
exhaust fan. If there were no provisions for make-up
air in this room, a supply fan would also have to be
sized. The supply cfm should equal the exhaust cfm.
Supply fan location should be as far as possible from
the exhaust fan.

9600 ft3
= 2400 cfm
4 min.

Exhaust fan to be sized

30 ft.
Louvers to supply
Makeup air
8 ft.

40 ft.

FAN FUNDAMENTALS

121

Introduction to FAN SELECTION


The pressures generated by fans in ductwork are
very small. Yet, accurately estimating the static
pressure is critical to proper fan selection.
Fan static pressure is measured in inches of water
gauge. One pound per square inch is equivalent
to 27.7 in. of water gauge. Static pressures in fan
systems are typically less than 2 in. of water gauge,
or 0.072 Psi. The drawing below illustrates how
static pressures are measured in ductwork with a
manometer.
A pressure differential between the duct and
the atmosphere will cause the water level in the
manometer legs to rest at different levels. This
difference is the static pressure measured in inches
of water gauge.
In the case of the exhaust fan below, the air is
being drawn upward through the ductwork because
the fan is producing a low pressure region at the
top of the duct. This is the same principle that
enables beverages to be sipped through a straw.

The amount of static pressure that the fan must


overcome depends on the air velocity in the
ductwork, the number of duct turns (and other
resistive elements), and the duct length. For
properly designed systems with sufficient make-up
air, the guidelines
in the table GUIDELINES
below can be used
STATIC PRESSURE
for estimating static pressure:
STATIC PRESSURE GUIDELINES
Non-Ducted

0.05 in. to 0.20 in.


0.2 in. to 0.40 in. per 100 feet of
duct (assuming duct air velocity
falls within 1000-1800 feet per
minute)
0.08 in. per fitting (elbow, register,
grill, damper, etc.)

Ducted

Fittings
Kitchen Hood
Exhaust
IMPORTANT!

DETERMINING STATIC PRESSURE (Ps)

0.625 in. to 1.50 in.

Static pressure requirements are significantly affected


by the amount of make-up air supplied to an area.
Insufficient make-up air will increase static pressure
and reduce the amount of air that will be exhausted.
Remember, for each cubic foot of air exhausted, one
cubic foot of air must be supplied.

Airflow to
exhaust fan

Ductwork

Exhaust Fan

Damper

4 ft.

6 ft.

Airflow
Atmospheric
Pressure

Duct
1 in.

Grill

Manometer
Water

To calculate the system losses, one must know the


ductwork system configuration (see Ductwork figure).
This duct is sized for air velocities of 1400 feet per
minute. Referring to the static pressure chart, that will
result in about 0.3 in. per 100 feet. Since we have
10 feet of total ductwork, our pressure drop due to
the duct is:
.3 in. x 10 ft. = .03 in.
100 ft.

Airflow out of
restaurant

There is also a 0.08 in. pressure drop for each


resistive element or fitting. For this example, there
are 5 fittings: one grill, two duct turns, one damper
and louver in the wall of the office. The total pressure
drop for fittings is:
5 x 0.08 in. = 0.4 in.
Therefore, the total pressure drop is:
0.03 in. + 0.40 in. = 0.43 in.*

* NOTE: For convenience in using selection charts, round this value up to the nearest 1/8 in., which would be 0.50 Ps.
122

FAN FUNDAMENTALS

Example

Solution

Greenheck Rep Directory


Greenheck Sales Office Representatives
ALABAMA
*Birmingham - Air-Tech Incorporated . . . . . . . . 205-942-7081
Dothan - Air-Tech Incorporated . . . . . . . . . . . 205-942-7081
*Mobile - Air-Tech Incorporated . . . . . . . . . . . 850-433-6443

ALASKA
*Anchorage - Stinebaugh & Company . . . . . . . . 907-345-8021

ARIZONA
*Phoenix - Air Specialty Products . . . . . . . . . . 480-377-9255
Tucson - Air Specialty Products . . . . . . . . . . . 520-623-0656

ARKANSAS

Forest Park - Mingledorffs Inc. . .


Gainesville - Mingledorffs Inc. . .
Lawrenceville - Mingledorffs Inc. .
Macon - Mingledorffs Inc. . . . . .
Marietta - Mingledorffs Inc. . . . .
*Norcross - Mingledorffs Inc. . . .
Savannah - Mingledorffs Inc. . . .
Statesboro - Mingledorffs Inc. . .
Valdosta - Mingledorffs Inc. . . . .
Warner Robins - Mingledorffs Inc.

Little Rock - John Prince Company . . . . . . . . . 501-666-5488


(Memphis, TN) - Gorham/Schaffler Inc. . . . . . . . 901-345-6100
Springdale - John Prince Company . . . . . . . . . 479-756-5240

HAWAII

CALIFORNIA

IDAHO

.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.

. 404-361-2474
. 770-297-9335
. 678-442-1060
. 478-477-3193
. 770-426-0551
. 770-446-6311
. 912-236-8122
. 912-764-8841
. 229-245-8200
. 478-953-3727

*Honolulu - Norman S. Wright Mechanical Equipment


. . . . . . . . . . . . . . . . . . . . . . . . . . . 808-678-3911

*Anaheim - Norman S. Wright/Airelink Mech. Equip. LLC


. . . . . . . . . . . . . . . . . . . . . . . . . . . 714-632-9800
Chico - Norman S. Wright Mechanical Equipment
. . . . . . . . . . . . . . . . . . . . . . . . . . . 530-345-9289
Fresno - Norman S. Wright Mechanical Equipment
. . . . . . . . . . . . . . . . . . . . . . . . . . . 559-271-3200
*Los Angeles - Norman S. Wright/Airelink Mech. Equip. LLC
. . . . . . . . . . . . . . . . . . . . . . . . . . . 818-367-6100
Pismo Beach - Norman S. Wright Mechanical Equipment
. . . . . . . . . . . . . . . . . . . . . . . . . . . 805-773-2810
*Sacramento - Norman S. Wright Mechanical Equipment
. . . . . . . . . . . . . . . . . . . . . . . . . . . 916-381-6666
*San Diego - Dave Dennison Co. Inc. . . . . . . . . . . . . 619-440-5061
*San Francisco - Norman S. Wright Mechanical Equipment
. . . . . . . . . . . . . . . . . . . . . . . . . . . 415-467-7600
Santa Clara - Norman S. Wright Mechanical Equipment
. . . . . . . . . . . . . . . . . . . . . . . . . . . 408-748-1304
Santa Rosa - Norman S. Wright Mechanical Equipment
. . . . . . . . . . . . . . . . . . . . . . . . . . . 707-568-3903

Boise - Technical Air Products Inc.. . . . . . . . . . 208-377-2071


(Spokane, WA) - Parmely & Associates Inc. . . . . . 509-443-1220

COLORADO

KENTUCKY

Colorado Springs - CFM Company .


*Denver - CFM Company . . . . . .
Evergreen - CFM Company . . . . .
Fort Collins - CFM Company . . . .

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

. 719-528-1116
. 303-761-2291
. 303-670-8994
. 970-493-7293

CONNECTICUT
*Newington - Buckley Associates Inc. . . . . . . . . 860-666-0555
Stratford - Buckley Associates Inc. . . . . . . . . . 203-380-2405

DELAWARE
*(Phil, PA) - Del-Ren Associates Inc. . . . . . . . . . 856-541-1776
Seaford - Ward-Boland Associates Inc. . . . . . . . 302-629-7006

FLORIDA
*Ft. Lauderdale/Miami - CORS-AIR . . . . . . .
Ft. Myers - Commercial Air Management Inc. .
Jacksonville - Florida Mechanical Products . .
*Orlando - Stan Weaver & Company . . . . . .
Pensacola - Air-Tech Incorporated . . . . . . .
*Tampa - Stan Weaver & Company . . . . . .
*West Palm Beach - CORS-AIR. . . . . . . . .

.
.
.
.
.
.
.

.
.
.
.
.
.
.

. 954-456-4300
. 239-277-0029
. 904-695-9295
. 407-581-6940
. 850-433-6443
. 800-783-6915
. 561-844-9767

.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.

. 229-432-5254
. 706-548-2563
. 770-458-4000
. 404-878-7755
. 706-854-0738
. 706-651-1950
. 912-265-5193
. 706-322-3870
. 770-918-9132

GEORGIA
Albany - Mingledorffs Inc. . . . . . . . .
Athens - Mingledorffs Inc. . . . . . . . .
*Atlanta - George Holden & Associates
- Mingledorffs Inc. . . . . . . .
Augusta - George Holden & Associates
- Mingledorffs Inc. . . . . . . .
Brunswick - Mingledorffs Inc. . . . . . .
Columbus - Mingledorffs Inc. . . . . . .
Conyers - Mingledorffs Inc. . . . . . . .

.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.

ILLINOIS
*Chicago - Brucker Company . . . . . . . . . . . . . 847-437-9690
(No. & Central Illinois) - Brucker Company . . . . . 309-691-5160
(So. Illinois) - H.C. Sharp Company Inc. . . . . . . . 314-351-6900

INDIANA
Evansville - RL Craig Company Inc. . . .
Fort Wayne - Colby Equipment Co. Inc. .
Gary - Brucker Company . . . . . . . . .
*Indianapolis - Colby Equipment Co. Inc.
Jasper - RL Craig Company Inc. . . . . .

REP DIRECTORY

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

. 800-422-1935
. 260-482-3773
. 219-861-0841
. 317-545-4221
. 800-422-1935

IOWA
Des Moines - Products Inc. . . . . . . . . . . . . . . 515-288-5738
*Sioux City - Commercial Air Management . . . . . 402-339-9177

KANSAS
*Kansas City - Jorban-Riscoe Associates Inc. . . . 913-438-1244
Wichita - Jorban-Riscoe Associates Inc. . . . . . . 316-687-3277
Louisville - RL Craig Company Inc. . . . . . . . . . . 502-244-1600

LOUISIANA
Baton Rouge - Air-Side Equipment Inc. . . . . . . . 225-216-3546
New Orleans - Air-Side Equipment Inc. . . . . . . . 504-837-2346
Shreveport - Reed Mechanical Equipment Inc.
. . . . . . . . . . . . . . . . . . . . . . . . . . . 318-687-8818

MAINE
*(Manchester, NH) - Buckley Associates Inc. . . . . 603-669-3566

MARYLAND
*Baltimore - Ward-Boland Associates Inc. . . . . . . 410-363-1833
Hagerstown - Ward-Boland Associates Inc. . . . . . 301-791-0187
*Silver Spring - C.G. Wood Company Inc. . . . . . . 301-565-3366

MASSACHUSETTS
*Boston - Buckley Associates Inc. . . . . . . . . . . 781-878-5000
*(Newington) - Buckley Associates Inc. . . . . . . . 860-666-0555

MICHIGAN
*Detroit - Michigan Air Products . . . . . . . . . . . 248-837-7000
Grandville - Michigan Air Products . . . . . . . . . . 616-534-8000
Saginaw - Michigan Air Products . . . . . . . . . . . 989-754-0409

MINNESOTA
*(Fargo, ND) - Therm-Air Sales Corporation . . . . . 701-282-9500
*Minneapolis - TMS Johnson, Inc. . . . . . . . . . . 763-544-5442

MISSISSIPPI
*Biloxi/Gulfport - Ward Mechanical Equipment . . . . 601-956-3002
*Jackson - Ward Mechanical Equipment . . . . . . 601-956-3002
(Memphis, TN) - Gorham/Schaffler Inc. . . . . . . . 901-345-6100

* Denotes representatives who carry local inventory.


124

.
.
.
.
.

Greenheck Sales Office Representatives


MISSOURI
*Kansas City - Jorban-Riscoe Associates Inc. . . . . . 913-438-1244
Springfield - Jorban-Riscoe Associates Inc.. . . . . 913-438-1244
St. Louis - H.C. Sharp Company Inc. . . . . . . . . . 314-351-6900

Chattanooga - Air Alliance . . . . . . . .


Knoxville - Air Alliance . . . . . . . . . . .
Memphis - Gorham/Schaffler Inc. . . . .
*Nashville - Underwood Air Systems Inc.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

. 423-622-5525
. 865-450-9770
. 901-345-6100
. 615-251-4555

MONTANA

TEXAS

Great Falls - Sound Air Inc. . . . . . . . . . . . . . . 406-727-8483

*Austin - Mechanical Reps Inc. . . . . . . .


*Dallas - Bartos Industries . . . . . . . . .
El Paso - Mechanical Representatives Inc.
*Fort Worth - Bartos Industries . . . . . . .
*Houston - H.D. Grant Company Inc.. . . .
*Lubbock - David G. Halley & Co. Inc. . . .
*San Antonio - Mechanical Reps Inc. . . .

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

.
.
.
.
.
.
.

. 512-444-1835
. 214-350-6871
. 915-779-1212
. 817-332-7906
. 713-668-8880
. 806-745-3405
. 210-650-9005

NEBRASKA
*Omaha - Commercial Air Management . . . . . . . 402-339-9177

NEVADA
*Las Vegas - Norman S. Wright Mechanical Equipment
. . . . . . . . . . . . . . . . . . . . . . . . . . . 702-361-4212
Reno - Norman S. Wright Mechanical Equipment
. . . . . . . . . . . . . . . . . . . . . . . . . . . 775-826-8622

NEW HAMPSHIRE

UTAH

*Manchester - Buckley Associates Inc. . . . . . . . 603-669-3566

Salt Lake City - Mechanical Products Intermountain


. . . . . . . . . . . . . . . . . . . . . . . . . . . 801-352-9003

NEW JERSEY

VERMONT

*Edison - Air Distribution Enterprises Inc. . . . . . . 732-553-0038


*(Philadelphia, PA) - Del-Ren Associates Inc. . . . . 856-541-1776

*(Albany, NY) - Buckley Associates Inc. . . . . . . . 518-438-7423

NEW MEXICO

Chesapeake - Hoffman & Hoffman Inc. . . . . . . . 757-548-1700


Richmond - Hoffman & Hoffman Inc. . . . . . . . . . 804-272-1500
Roanoke - Hoffman & Hoffman Inc. . . . . . . . . . 540-725-8701
*(Silver Spring, MD) C.G. Wood Company Inc. . . . . 301-565-3366

*Albuquerque - Mechanical Representatives Inc.


. . . . . . . . . . . . . . . . . . . . . . . . . . . 505-821-2563

NEW YORK
*Albany - Buckley Associates Inc. . . . . . .
*Buffalo - H & V Commercial Ind Sales Inc. .
*New York - Air Distribution Enterprises Inc.
Rochester - T.H. Herman Inc. . . . . . . . . .
Syracuse - George Race & Associates Inc. .

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

. 518-438-7423
. 716-897-5010
. 516-256-4800
. 585-394-8386
. 315-455-4901

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

. 828-252-5782
. 704-364-4700
. 336-292-8777
. 919-781-8011
. 910-791-4775

NORTH CAROLINA
Asheville - Hoffman & Hoffman Inc. . .
Charlotte - Hoffman & Hoffman Inc. . .
*Greensboro - Hoffman & Hoffman Inc.
Raleigh - Hoffman & Hoffman Inc. . . .
Wilmington - Hoffman & Hoffman Inc. .

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

NORTH DAKOTA
*Fargo - Therm-Air Sales Corporation . . . . . . . . 701-282-9500

WASHINGTON
*Seattle - Dorse & Company Inc. . . . . . . . . . . . 206-284-2610
Spokane - Parmely & Associates Inc. . . . . . . . . 509-443-1220

WASHINGTON, D.C.
*(Silver Spring, MD) - C.G. Wood Company Inc. . . . 301-565-3366

WEST VIRGINIA
Charleston - Mason & Barry Inc. . . . . . . . . . . . 304-755-0781

WISCONSIN
Green Bay - Vyron Corporation . . . . .
Madison - Vyron Corporation . . . . . .
Milwaukee - Vyron Corporation . . . . .
Wisconsin Rapids - Vyron Corporation

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

. 920-405-8822
. 608-850-3400
. 262-783-3600
. 715-421-2100

WYOMING

OHIO
*Cincinnati - Environmental Air Products
*Cleveland - Air Control Products Inc. . .
*Columbus - Air Systems Diversified Inc.
*Dayton - Environmental Air Products . .
Toledo - Air Control Products Inc. . . . .

VIRGINIA

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

. 513-489-9494
. 440-526-3020
. 614-291-0960
. 513-489-9494
. 419-380-8990

OKLAHOMA
Oklahoma City - Engineered Equipment. . . . . . . 405-525-7722
Tulsa - Engineered Equipment. . . . . . . . . . . . . 918-625-1005

OREGON
Medford - Johnson Air Products . . . . . . . . . . . 541-772-2690
*Portland - Johnson Air Products . . . . . . . . . . 503-234-5071

PENNSYLVANIA
*Harrisburg - H & H Sales Associates Inc. .
*Philadelphia - Del-Ren Associates Inc. . .
Pittsburgh - Pittsburgh Air Systems Inc. . .
Scranton - Colman Sales Co. Inc. . . . . .

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

. 717-796-2401
. 856-541-1776
. 412-741-3070
. 570-587-1188

RHODE ISLAND
*(Boston, MA) - Buckley Associates Inc. . . . . . . . 781-878-5000

SOUTH CAROLINA
Columbia - Hoffman & Hoffman Inc. . . . . . . . . . 803-765-9360
Greenville - Hoffman & Hoffman Inc. . . . . . . . . . 864-676-1888
Mt. Pleasant - Hoffman & Hoffman Inc. . . . . . . . 843-884-3201

(Great Falls, MT) - Sound Air Inc. . . . . . . . . . . 406-727-8483


(Ft. Collins, CO) - CFM Company . . . . . . . . . . . 970-493-7293

CANADA
*EH Price Limited
*Calgary . . . . . . . . . . . . . . . . . .
*Charlesbourg. . . . . . . . . . . . . . .
*Dartmouth . . . . . . . . . . . . . . . .
*Edmonton . . . . . . . . . . . . . . . .
*Hamilton . . . . . . . . . . . . . . . . .
*Kelowna . . . . . . . . . . . . . . . . .
*London . . . . . . . . . . . . . . . . . .
*Montreal . . . . . . . . . . . . . . . . .
*Ottawa . . . . . . . . . . . . . . . . . .
*Regina . . . . . . . . . . . . . . . . . .
*Saskatoon . . . . . . . . . . . . . . . .
*Toronto . . . . . . . . . . . . . . . . . .
*Vancouver . . . . . . . . . . . . . . . .
*Vancouver Island . . . . . . . . . . . .
*Winnipeg . . . . . . . . . . . . . . . . .
Global Mechanical Systems Ltd.
*New Brunswick & Prince Edward Island

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

. 403-777-2790
. 418-849-2306
. 902-468-1310
. 780-477-9231
. 905-383-3599
. 250-765-7226
. 519-451-5100
. 514-334-9804
. 613-725-2029
. 306-525-2367
. 306-931-3316
. 905-660-0066
. 604-777-1712
. 250-475-2500
. 204-982-2222

. . . . 506-857-4887

SOUTH DAKOTA
Sioux Falls - Climate Systems, Inc.. . . . . . . . . . 605-334-2164

TENNESSEE
Blountville - Air Alliance . . . . . . . . . . . . . . . . 423-279-7117
REP DIRECTORY

125

International Agents
ARGENTINA - Air-Technik S.R.L. d/b/a Cermac
. . . . . . . . . . . . . . . . . . . . . . . . . . 541142923453
AUSTRALIA - Imagro Australia Pty Ltd . . . . . . 61-892863220
BAHAMAS - Cors-Air Bahamas . . . . . . . . . . . 954-456-4300
BAHRAIN - Awal Products Co. W.L.L. . . . . . 9733177813535
BRUNEI - Benaire Engineering PTE, Ltd . . . . . . . 6567410280
*CARIBBEAN ISLANDS - SAEG Engineering Group
. . . . . . . . . . . . . . . . . . . . . . . . . . . 305-718-8146
CHILE - Roster Ltda . . . . . . . . . . . . . . . . . . 5623651876
CHINA - BEIJING - Hongen Times of Prosperity Science and
Technology (Beijing) Co Ltd . . . . . . . . . 86-10-64856900
Century Liangji (Beijing) Technology Dev . . 86-22-2373-5760
CHINA - CHENGDU CENTRAL WEST CHINA Chengdu Xiongfeng Eng Equip Co Ltd . . . 86-28-8737-4375
CHINA - GUANGZHOU - Guangzhou Hongxin Co. Ltd.
. . . . . . . . . . . . . . . . . . . . . . . . 86-2-0-38-85-2303
CHINA - SHANGHAI CITY - Techair Shanghai
Enterprise Co. Ltd. . . . . . . . . . . . . . . . 862152930291
CHINA - TIANJIN - Tianjin ZhongHeShengDa International . . .
Trade Co. Ltd . . . . . . . . . . . . . . . . . 86-22-2726-3030
Tianjin Zhengli Machine and Equipment Sales Co Ltd.
. . . . . . . . . . . . . . . . . . . . . . . . 86-22-2373-5760
COLOMBIA - SAEG Colombia . . . . . . . . . . . . . 5716131749
COSTA RICA - Strong Intl Central America - Costa Rica
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 5062341640
DOMINICAN REPUBLIC - SAEG Dominican Republic
. . . . . . . . . . . . . . . . . . . . . . . . . . . 809-473-7234
ECUADOR - SAEG Ecuador . . . . . . . . . . . . . 305-718-8146
EGYPT - Contact . . . . . . . . . . . . . . . . . . . . 2027941517
EL SALVADOR - Strong Intl Central America . . . 50322298939
GUAM - American International Supply Inc. . . . . 671-647-5061
GUATEMALA - Strong Intl Central America - Guatemala
. . . . . . . . . . . . . . . . . . . . . . . . . . . 50224850434
HONDURAS - Strong Intl Central America . . . . . 5045504888
HONG KONG - Ziehl-ebm (H.K.) Ltd. . . . . . . . 852-2481-7233
INDIA - WEST & SOUTH - Chatur Parmanand Vaswani
. . . . . . . . . . . . . . . . . . . . . . . . . . . 91222844303
ISRAEL - M.N. Engineering Co. . . . . . . . . . . . 97239799833
JAPAN - Ninon Enterprises Ltd. . . . . . . . . . 81-98-936-6099

JORDAN - Sources for Engineering Supplies Co. Ltd.


. . . . . . . . . . . . . . . . . . . . . . . . . .
.
.
.
.

KOREA - ACEM Trading Corp.. . . . . . . . . .


KUWAIT - Gulf Facilities General Trading . . .
LEBANON - Air Distribution Center S.A.R.L. . .
MALAYSIA - Gt-Gulf (m) Sdn. Bhd. . . . . . . .
MEXICO - CANCUN - Versa Rep. S.A. de C.V.

. 96265525255
. 822-598-2793
. . 9655719234
. 961-135-3823
. 603-7957-021

. . . . . . . . . . . . . . . . . . . . . . . . . . 529988432574

MEXICO - CHIHAUHAU - Mechanical Representatives


(Mexico Sales) . . . . . . . . . . . . . . . . . . 915-779-1212

MEXICO - GUADALAJARA - Proveedora Industrial


Panamericana S.A. de . . . . . . . . . . . . . . 52338259325
*MEXICO - MEXICO CITY - Versa Comercializadora
S.A. de C.V. . . . . . . . . . . . . . . . . . . . 525556041377
MEXICO - MONTERREY - Proveedora Termica del Norte
S.A. de C.V. . . . . . . . . . . . . . . . . . . . 528181257300
MEXICO - TIJUANA - Becerril . . . . . . . . . . 526646821523
OMAN - Khimji Ramdas - A/C Division . . . . . . . 968-795-901
PAKISTAN - Airtech International . . . . . . . . . . 92214980308
PANAMA - SAEG Panama . . . . . . . . . . . . . . . 5072606783
PERU - SAEG Peru . . . . . . . . . . . . . . . . . . . 5112261600
PHILIPPINES - Fahrenheit Industries Inc. . . . . 63-2-374-3293
PUERTO RICO - Technical Distributors Inc. . . . . 787-274-1818
QATAR - Gulf Facilities Trading Co. WLL . . . . . . . 9744501152
*SAUDI ARABIA - Al Saadeh Trading Establishment
. . . . . . . . . . . . . . . . . . . . . . . . . . . 96614780643
SINGAPORE - Asiatic Engineering Pte Ltd. . . . . 65-6291-8282
Insync Engineering Pte Ltd . . . . . . . . . . . 65-6665-6022
Bio-Pointe Pte Ltd. . . . . . . . . . . . . . . . . 65-6748-8911
SRI LANKA - Techno-Maart (Pte) Ltd. . . . . . . . 94114717500
TAIWAN - Techair Enterprise Co. Ltd. . . . . . 886-2-2731-9100
THAILAND - Ventilation Engineering Company Ltd.
. . . . . . . . . . . . . . . . . . . . . . . . . . . 66253090602
TURKEY - ATC Air Trade Centre Ltd. STI. . . . . 902122834510
*U.A.E. - Western Technological Equipment . . . . 97142994124
URUGUAY - Ing Schellemberg S.R.L. . . . . . . . . . 59822037200
VENEZUELA IMEX Importacion Y Exportacion
. . . . . . . . . . . . . . . . . . . . . . . . . . 582432327021
VIETNAM - Asiatic Engineering Pte Ltd. . . . . . . 84-8512-4436
YEMEN - Al-Rashed Trading Centre . . . . . . . . 967-124-5699

* Denotes representatives who carry local inventory.

Food Service Representatives


AIR FLOW SPECIALISTS
Davie, FL . . . . . . . . . . . . . . . .
Indian Harbour Beach, FL . . . . . . .
AIR SOLUTIONS & BALANCING, LLC
Merrimack, NH . . . . . . . . . . . . .
AIR-TECH INCORPORATED
Pensacola, FL . . . . . . . . . . . . . .
BYRNE & ASSOCIATES
Fairfield, OH . . . . . . . . . . . . . . .
Louisville, KY . . . . . . . . . . . . . .
COMMERCIAL KITCHEN REPS
Rochester, NY. . . . . . . . . . . . . .
COMMERCIAL VENTILATION SOLUTIONS
Edwardsville, IL . . . . . . . . . . . . .
COURTNEY MARKETING INC
Phoenix, AZ . . . . . . . . . . . . . . .
Santa Fe, NM . . . . . . . . . . . . . .
CULINARY EQUIPMENT
Aurora, CO . . . . . . . . . . . . . . .
Colorado Springs, CO . . . . . . . . .
EQUIPMENT MARKETING ASSOCIATES
San Pedro, CA . . . . . . . . . . . . .
ETTINGER-ROSINI & ASSOCIATES
Arlington, TX . . . . . . . . . . . . . .
Dallas, TX . . . . . . . . . . . . . . . .

126

REP DIRECTORY

. . . . . . . . . 954-727-9507
. . . . . . . . . 321-777-8877
. . . . . . . . . 603-262-9292
. . . . . . . . . 850-433-6443
. . . . . . . . . 513-829-9117
. . . . . . . . . 502-896-4056
. . . . . . . . . 585-249-0520
LLC
. . . . . . . . . 618-656-9873
. . . . . . . . . 623-434-1113
. . . . . . . . . 505-466-9171
. . . . . . . . . 303-371-9544
. . . . . . . . . 719-359-5182
. . . . . . . . . 310-521-9071
. . . . . . . . . 817-460-5800
. . . . . . . . . 214-343-2548

GMD FOODSERVICE MARKETING


Ann Arbor, MI . . . . . . . . . . . .
Grand Haven, MI . . . . . . . . . .
INTERMOUNTAIN FOOD EQUIPMENT
Salt Lake City, UT . . . . . . . . .
MARKETEAM
Vancouver, WA . . . . . . . . . . .
MILLER & STRYKER ASSOCIATES
Wood Dale, IL . . . . . . . . . . . .
PARAGON MARKETING
Lenexa, KS . . . . . . . . . . . . .
PRO-QUIP FOODSERVICE E&S
Little Rock, AR . . . . . . . . . . .
Memphis, TN . . . . . . . . . . . .
Slidell, LA . . . . . . . . . . . . . .
SCHMID DEWLAND ASSOCIATES
Gibbsboro, NJ . . . . . . . . . . .
TD MARKETING COMPANY INC
East Rutherford, NJ . . . . . . . .
VENTILATION CONCEPTS
Whispering Pines, NC . . . . . . .
WARD-BOLAND
Smyrna, DE . . . . . . . . . . . . .
WOOLSEY & ASSOCIATES
Waukesha, WI. . . . . . . . . . . .

. . . . . . . . . . . 734-786-3470
. . . . . . . . . . . 616-846-3444
. . . . . . . . . . . 801-534-1964
. . . . . . . . . . . 360-696-3984
. . . . . . . . . . . 630-766-0077
. . . . . . . . . . . 913-469-6868
. . . . . . . . . . . 501-221-7120
. . . . . . . . . . . 901-347-0675
. . . . . . . . . . . 985-649-1144
. . . . . . . . . . . 856-783-3400
. . . . . . . . . . . 201-935-1600
. . . . . . . . . . . 910-949-4521
. . . . . . . . . . . 302-629-7006
. . . . . . . . . . . 262-436-0102

Place
Stamp
Here

Remember to use ...

GREENHECK VOLUME 22
QD CATALOG ADDRESS CORRECTION
PO BOX 410
SCHOFIELD WI 54476-0410

web address:
www.greenheck.com

W h e n Q u i c k e r i s B e t t e r - G re e n h e c k i s B e s t .

Greenhecks Quick Delivery


Program provides many options
to help you meet your projects
schedule. Stocking warehouses
and distribution centers around
the world ensure same-day
pickup and same-day shipment
for orders in by 2 p.m. (CST).
Hundreds of custom products
can be manufactured through
Quick Build in just days.
PICK UP OR WE SHIP. ALWAYS QUICK.

LOADING ASSISTANCE.

Anywhere. Anytime.
Regional warehouses are nearby
and fully stocked

1 HOUR
LOCAL STOCK
CUSTOMER
PICKUP

QD STOCK
U.S.

CALIFORNIA
FLORIDA
NEVADA
NEW JERSEY
NORTH CAROLINA

OHIO
TEXAS
WISCONSIN

WORLDWIDE
CHINA
MEXICO
UNITED ARAB EMIRATES
MANUFACTURING LOCATIONS
CALIFORNIA
KENTUCKY
WISCONSIN
CHINA

SAME DAY
OR NEXT DAY
SHIPMENTS

1-DAY
CUSTOM BUILT
PRODUCTS
SHIPPED IN
ONE DAY

3-5-10-DAY
CUSTOM BUILT
PRODUCTS SHIPPED
IN 3, 5 OR 10 DAYS

STANDARD LEAD TIME


ALL GREENHECK PRODUCTS ARE
SHIPPED AS FAST AS POSSIBLE
FROM ONE OF OUR FOUR
MANUFACTURING PLANTS.

Você também pode gostar