Você está na página 1de 160

PDMS

User Bulletin
Version 11.6.SP5

pdms1165/PDMS Bulletin
Issue 311008

PLEASE NOTE:
AVEVA Solutions has a policy of continuing product development: therefore, the
information contained in this document may be subject to change without notice.
AVEVA SOLUTIONS MAKES NO WARRANTY OF ANY KIND WITH REGARD TO
THIS DOCUMENT, INCLUDING BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE.
While every effort has been made to verify the accuracy of this document, AVEVA
Solutions shall not be liable for errors contained herein or direct, indirect, special,
incidental or consequential damages in connection with the furnishing, performance
or use of this material.

This manual provides documentation relating to products to which you may


not have access or which may not be licensed to you. For further information
on which Products are licensed to you please refer to your licence conditions.

Copyright 1974 through 2008 AVEVA Solutions Limited

All rights reserved. No part of this document may be reproduced, stored in a retrieval
system or transmitted, in any form or by any means, electronic, mechanical,
photocopying, recording or otherwise, without prior written permission of AVEVA
Solutions.

The software programs described in this document are confidential


information and proprietary products of AVEVA Solutions or its licensors.

For details of AVEVA's worldwide sales and support offices, see our website at
http://www.aveva.com

VANTAGE PDMS Version 11.6.SP5


User Bulletin

ii

Revision History
Issue

Notes

181104

Final draft for PDMS 11.6.0

140705

Final amendments for PDMS 11.6.SP1 marked *sp1*

261005

Amendments for PDMS 11.6.SP2 marked *sp2*

281005

Amendments & additions for defects

150506

Amendments for PDMS 11.6.SP3 marked *sp3*.


Along with program corrections and minor enhancements
(see chapter 8), changes include:
Piping Application Enhancements
Other Design Enhancements (see chapter 3)
Changes to support Global 2.4
Support for AutoCAD 2005, 2006 in AutoDRAFT
In addition page headers have been corrected.

130207

Amendments for PDMS 11.6.SP4 marked *sp4*.


Along with program corrections and minor enhancements
(see chapter 11), major enhancements include:

Pipe bending checks & pipe sketches


Parameterised Property Attributes (new Chapter 6)
Weights on Isometrics
New options for flow arrows on Isometrics
Intellectual Property protection for PML applications
A new chapter 10 covers updates to standard projects:
Australian Steel Catalogue
MDS Lexicon database
Chapter 1 (Introduction) has also been updated, notably the
sections on Support status and Future considerations, along
with minor corrections and improvements throughout.
Improvements related to Global 2.4.sp1 are also detailed in
this document:

311008

Query Global Network status from all modules


(section 2.8)
Admin queries for Remote databases and purging
transaction commands (Chapter 7)
Amendments for PDMS 11.6.SP5 marked *sp5*
Includes enhancements to Isodraft, Admin (primarily for
Global) and an additional section on fixed defects.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

Revision history-i

Contents
1

Introduction...................................................................................................1-1

1.1
1.2
1.3
1.4

Overview .................................................................................................................... 1-1


Summary of Changes at PDMS 11.6........................................................................ 1-2
Summary of Changes at PDMS 11.6.SP1 *sp1*..................................................... 1-3
Summary of Changes at PDMS 11.6.SP2 *sp2*..................................................... 1-3
1.4.1 Support for Final Designer.............................................................................. 1-3
1.4.2 Support for Laser Model Interface.................................................................. 1-3
1.4.3 Miscellaneous Improvements.......................................................................... 1-4
Summary of Changes at PDMS 11.6.SP3 *sp3*..................................................... 1-4
1.5.1 Piping application ............................................................................................ 1-4
1.5.2 Draft 3D view ................................................................................................... 1-4
1.5.3 Support of Global 2.4 ....................................................................................... 1-4
1.5.4 Miscellaneous Improvements.......................................................................... 1-5
Summary of Changes at PDMS 11.6.SP4 *sp4*..................................................... 1-5
1.6.1 Pipe bending checks & sketches...................................................................... 1-5
1.6.2 Parameterised Property Attributes ................................................................ 1-5
1.6.3 Weights on Isometrics...................................................................................... 1-6
1.6.4 Australian Steel Catalogue ............................................................................. 1-6
1.6.5 Intellectual Property protection for PML applications .................................. 1-6
1.6.6 Changes to related products............................................................................ 1-6
Summary of Changes at PDMS 11.6.SP5 *sp5*..................................................... 1-6
1.7.1 Isodraft Enhancements ................................................................................... 1-7
1.7.2 Changes to related products............................................................................ 1-7
Documentation *sp1* *sp2* *sp5* ........................................................................ 1-7
Operating System and Hardware Environment *sp4* ........................................ 1-8
Upgrading from previous releases *sp5* ............................................................... 1-9
Compatibility
(update) *sp3*............................................................................ 1-10
Notice of change in support status (update) *sp4*................................................ 1-10
1.12.1 PDMS 11.4 and earlier ............................................................................. 1-10
1.12.2 PDMS 11.5
(update) *sp4* ............................................................... 1-10
Future considerations ............................................................................................. 1-10
1.13.1 AutoCAD integration
(update) *sp4*................................................. 1-10
1.13.2 Windows versions
(update) *sp5* ..................................................... 1-10
1.13.3 Use of UNIX servers (update) *sp5* .................................................... 1-11
1.13.4 PML features
(update) *sp5* ............................................................ 1-11
1.13.5 Design Comparison with Schematics *sp5* .......................................... 1-12
1.13.6 ISODRAFT symbol files
*sp5* ............................................................ 1-12

1.5

1.6

1.7
1.8
1.9
1.10
1.11
1.12
1.13

PDMS GUI General changes .....................................................................2-1

2.1
2.2

Glossary ..................................................................................................................... 2-1


Application framework.............................................................................................. 2-3
2.2.1 Toolbars ............................................................................................................ 2-3
2.2.2 Dockable Windows ........................................................................................... 2-3
2.2.3 Floating Windows ............................................................................................ 2-3
2.2.4 Status Bar ........................................................................................................ 2-3
2.2.5 Session Settings ............................................................................................... 2-4
Tabbed Graphics form............................................................................................... 2-4
Database Explorers ................................................................................................... 2-5

2.3
2.4

VANTAGE PDMS Version 11.6.SP5


User Bulletin

Contents-i

Contents

2.5
2.6
2.7
2.8

2.4.1 History .............................................................................................................. 2-5


2.4.2 Explorer Settings ............................................................................................. 2-6
2.4.3 Filters ............................................................................................................... 2-6
2.4.4 Copy rules......................................................................................................... 2-6
2.4.5 Drag-and-drop .................................................................................................. 2-7
2.4.6 Mouse Actions .................................................................................................. 2-9
2.4.7 ToolTips ............................................................................................................ 2-9
2.4.8 Updates............................................................................................................. 2-9
Drawlist ..................................................................................................................... 2-9
My Data ................................................................................................................... 2-10
UNDO / REDO ........................................................................................................ 2-10
Information about Global network status *sp4* ................................................. 2-10

PDMS Design Changes ................................................................................3-1

3.1
3.2
3.3

General GUI improvements ..................................................................................... 3-1


Element Selection (update) *sp4* ......................................................................... 3-3
Quick Pipe Routing ................................................................................................... 3-4
3.3.1 Improvements for PDMS 11.6.sp3 *sp3* ..................................................... 3-4
Pipe Component modification................................................................................... 3-5
Pipe Component creation.......................................................................................... 3-6
Pipe Component Reselection .................................................................................... 3-6
Equipment Editing.................................................................................................... 3-6
Design Areas.............................................................................................................. 3-6
New Piping Pseudo Attributes ................................................................................. 3-7
3.9.1 Branch Surface Area........................................................................................ 3-7
3.9.2 Range of Angles or Radii ................................................................................. 3-7
3.9.3 Data Consistency ............................................................................................. 3-8
New Attributes for Material Management .............................................................. 3-9
3.10.1 Status attribute for use in MTO output .................................................... 3-9
3.10.2 Additional attributes for spool MTO........................................................ 3-10
3.10.3 Additional attributes for Piping Specifications ....................................... 3-10
Extract Refresh ....................................................................................................... 3-10
Add to Drawlist tool bar
*sp1* .......................................................................... 3-10
Piping component (e.g. flange) alignment *sp1* .................................................. 3-10
3.13.1 New attribute for PTCA, PTAX, PTMI, PTPOS...................................... 3-11
3.13.2 New pseudo attributes for branch members ........................................... 3-11
3.13.3 Connection Command............................................................................... 3-11
3.13.4 New Datacon warning messages.............................................................. 3-11
HVAC application new components *sp1*......................................................... 3-11
Pipe bending checks
*sp4*................................................................................. 3-12
3.15.1 Definitions ................................................................................................. 3-12
3.15.2 Design Database additions (update) *sp4*........................................... 3-12
3.15.3 Production Pipes Check Form .................................................................. 3-13
3.15.4 Setting up Production Checks .................................................................. 3-16
3.15.5 Running a Production Check.................................................................... 3-17
3.15.6 Automatic Flange Alignment ................................................................... 3-20
Laser model and its manipulation *sp2* ............................................................. 3-21
Check Isometrics ..................................................................................................... 3-21
Look Explicit
*sp3* .......................................................................................... 3-22

3.4
3.5
3.6
3.7
3.8
3.9

3.10

3.11
3.12
3.13

3.14
3.15

3.16
3.17
3.18

VANTAGE PDMS 11.6.SP5


User Bulletin

Contents-ii

Contents

Piping Isometric Enhancements .................................................................4-1

4.1
4.2
4.3

General GUI improvements ..................................................................................... 4-1


Parameterised MTOL & MTOQ ............................................................................... 4-1
Use of temperature and pressure for selection........................................................ 4-1
4.3.1 Standard Bolt Hole DB Change ...................................................................... 4-1
4.4 User-defined Material Lists...................................................................................... 4-2
4.5 Spooler Pulled bend numbering *sp1* ................................................................ 4-2
4.6 Isodraft Pulled bend numbering *sp1* ............................................................... 4-2
4.7 Weights on Isometrics
*sp4* ............................................................................... 4-2
4.7.1 User Interface .................................................................................................. 4-3
4.7.2 Command Syntax............................................................................................. 4-3
4.7.3 OUTPUT........................................................................................................... 4-3
4.7.4 Example Material List..................................................................................... 4-4
4.8 Flow Arrow settings
*sp4*................................................................................... 4-5
4.9 Isodraft SKEY Enhancements *sp5* .................................................................... 4-5
4.9.1 New UNBW SKEY........................................................................................... 4-5
4.9.2 New FY** SKEY .............................................................................................. 4-6
4.9.3 Tee/Olet SKEY Enhancement ......................................................................... 4-6
4.10 Improved Continuation Sheet Options *sp5* ......................................................... 4-7
4.10.1 New Annotation Options ............................................................................ 4-7
4.11 Placing of Dimension Labels *sp5* ....................................................................... 4-9
4.12 Improved Dimensioning Oriented Welds *sp5* ................................................ 4-10

Drawing Production Enhancements ...........................................................5-1

5.1

General GUI improvements ..................................................................................... 5-1


5.1.1 Merged sub-applications.................................................................................. 5-2
5.1.2 User utility menu............................................................................................. 5-3
5.1.3 Dimension and 2D drawing forms .................................................................. 5-3
5.1.4 Labelling rationalisation ................................................................................. 5-3
Use of the 3D features in DRAFT (update) *sp1* .................................................. 5-4
5.2.1 3D Commands .................................................................................................. 5-4
5.2.2 3D user interface.............................................................................................. 5-4
5.2.3 Managing 3D view content (Drawlist) ............................................................ 5-5
5.2.4 Multi Selection ................................................................................................. 5-6
5.2.5 Scale control ..................................................................................................... 5-8
5.2.6 UNDO/REDO ................................................................................................... 5-8
5.2.7 Modify Star....................................................................................................... 5-8
5.2.8 3D to 2D (Update Design)................................................................................ 5-8
5.2.9 2D to 3D............................................................................................................ 5-9
5.2.10 Display of 2D view frame in the 3D view gadget ...................................... 5-9
5.2.11 Update control........................................................................................... 5-10
5.2.12 View Type .................................................................................................. 5-10
5.2.13 Section Planes ........................................................................................... 5-10
5.2.14 Representation in 3D view ....................................................................... 5-10
5.2.15 Viewfinder Shortcut menu. ...................................................................... 5-11
5.2.16 3D view Shortcut menu additions related to view finder. ...................... 5-11
Template drawings.................................................................................................. 5-12
Section planes.......................................................................................................... 5-12
5.4.1 Improvements for *sp3* ................................................................................ 5-12

5.2

5.3
5.4

VANTAGE PDMS 11.6.SP5


User Bulletin

Contents-iii

Contents

5.5
5.6
5.7
5.8

Background processes ............................................................................................. 5-13


AutoCAD integration with Final Designer ............................................................ 5-13
UNDO/REDO
*sp1* ......................................................................................... 5-14
Pipe Sketch ADP
*sp4*..................................................................................... 5-14
5.8.1 Producing Pipe Sketches ............................................................................... 5-14
5.8.2 How to Use the Pipe Sketches Form............................................................. 5-14
5.8.3 Pipe Sketch Administration .......................................................................... 5-17
5.8.4 Styles .............................................................................................................. 5-19
5.8.5 Common Object .............................................................................................. 5-19
5.8.6 Log Messages ................................................................................................. 5-20
5.8.7 Table Definition Example.............................................................................. 5-20
5.8.8 Dimensions..................................................................................................... 5-21
5.8.9 Tags ................................................................................................................ 5-21

Parameterised Property Attributes .............................................................6-1

6.1
6.2
6.3

Introduction
*sp4*.............................................................................................. 6-1
Property attributes affected *sp4* ........................................................................ 6-1
Upgrade Requirement
*sp4* ............................................................................... 6-2

Admin enhancements for Global.................................................................7-1

7.1
7.2
7.3

Querying Remote databases *sp4*........................................................................ 7-1


Purge Transaction commands *sp4*..................................................................... 7-4
User Interface enhancements *sp5* .................................................................... 7-5
7.3.1 Admin elements Form ..................................................................................... 7-5
7.3.2 DB Allocation (By Location/By Database) Forms .......................................... 7-5
7.3.3 Create DB Form ............................................................................................... 7-5
7.3.4 Create Location Form ...................................................................................... 7-6
7.3.5 Extract Control Form ...................................................................................... 7-6
7.3.6 Main Tool bar ................................................................................................... 7-6
7.3.7 DICE Form ....................................................................................................... 7-6
7.3.8 Transaction Command Timings Form............................................................ 7-6
7.3.9 Create MDB Form ........................................................................................... 7-6

Customisation...............................................................................................8-1

8.1
8.2
8.3

Application switching................................................................................................ 8-1


Forms & Menus (PML) Enhancements ................................................................... 8-1
Further PML (Forms & Menus) changes *sp1* ..................................................... 8-3
8.3.1 Gadget layout management ............................................................................ 8-3
8.3.2 Form enhancements ........................................................................................ 8-4
8.3.3 New SLIDER gadget........................................................................................ 8-4
8.3.4 New radio group facility .................................................................................. 8-4
8.3.5 List gadget enhancements............................................................................... 8-5
8.3.6 Option gadget enhancements .......................................................................... 8-5
8.3.7 Miscellaneous ................................................................................................... 8-5
Internationalisation .................................................................................................. 8-6
Localisation ............................................................................................................... 8-6
PML Encryption
*sp4*........................................................................................ 8-7
8.6.1 Decryption ........................................................................................................ 8-7
8.6.2 Encryption ........................................................................................................ 8-7
8.6.3 Buffering........................................................................................................... 8-8

8.4
8.5
8.6

VANTAGE PDMS 11.6.SP5


User Bulletin

Contents-iv

Contents

Incompatible PML changes..........................................................................9-1

9.1
9.2
9.3
9.4
9.5
9.6

Summary ................................................................................................................... 9-1


Functional changes at 11.6 ....................................................................................... 9-1
Layout changes at 11.6 ............................................................................................. 9-2
Functional changes
*sp1* .................................................................................... 9-3
9.4.1 Multi-selection list Extra Start and Stop meta-events............................... 9-3
Layout changes
*sp1* ......................................................................................... 9-4
Parameterised Property attributes *sp4*.............................................................. 9-4

10

Updates to standard projects ....................................................................10-1

10.1 Supports catalogue for MDS *sp4* ..................................................................... 10-1


10.2 Australian Steel Catalogue *sp4* ...................................................................... 10-1

11

Product Faults and User Requests ...........................................................11-1

11.1 Known faults and Outstanding Issues................................................................... 11-1


11.1.1 Windows fault correction available....................................................... 11-1
11.1.2 Windows faults file locking.................................................................... 11-1
11.1.3 Microsoft .NET Framework Hotfixes KB886903 & KB886904 .............. 11-1
11.1.4 PDMS faults & limitations future corrections (update) *sp4* ............ 11-2
11.2 Faults corrected and minor enhancements ........................................................... 11-4
11.3 Faults corrected and minor enhancements *sp1* ............................................... 11-17
11.4 Faults corrected and minor enhancements *sp2* ............................................... 11-22
11.5 Faults corrected and minor enhancements *sp3* ............................................... 11-28
11.6 Faults corrected and minor enhancements *sp4* ............................................... 11-38
11.6.1 Corrections to Global 2.4.SP1 (issued with PDMS 11.6.sp4)................ 11-46
11.7 Faults corrected and minor enhancements *sp5* ............................................... 11-47
11.7.1 Corrections consolidated from previous fix releases: ............................ 11-48
11.7.2 Corrections to Global 2.4.SP2 (issued with PDMS 11.6.SP5)............... 11-52

VANTAGE PDMS 11.6.SP5


User Bulletin

Contents-v

Contents

VANTAGE PDMS 11.6.SP5


User Bulletin

Contents-vi

Introduction
This bulletin describes the new and enhanced functionality available in
the fifth service pack (SP5) for PDMS 11.6, including information about
the earlier releases of PDMS 11.6. It gives an overview of the major
changes at 11.6, which are described in full in new and revised User
Documentation. Minor changes and enhancements are also described in
this Bulletin.
There are no major changes to PDMS itself in the various service packs.
There are, however, changes in some of the related products, together
with corrections, small changes and enhancements, and revisions to some
of the User Documentation.
The most significant changes in this document for the various service
packs are indicated as appropriate: *sp1*, *sp2*, *sp3*, *sp4*. *sp5*.

1.1

Overview
PDMS has long led the way for 3D Plant Design. It has always been
object-based, using the concept of building a computer model of the plant,
in order to ensure that the design works in every detail. Deliverables are
always consistent as they are derived from this model. Interaction with
this model has used realistic colour-shaded images for over 15 years.
PDMS 11.5 introduced the first steps of a programme to build the Next
Generation user interface for PDMS, based on the latest Windows
technology. PDMS 11.6 brings a further leap forward in the graphical
user interface. Major new features introduced at PDMS 11.6 include:

Use of the latest Microsoft .NET technology to provide Windows


graphical user interface (GUI) standards for familiarity and ease of
integration. This gives an appearance, and many GUI features,
similar to Microsofts Office 2003.

A simpler mechanism for the various add-in applications for DESIGN,


both those produced by AVEVA and by customers.

Extension of the new Model Editor, introduced at PDMS 11.5, and


provision of a new Plant Editor for Piping and Equipment. Refer to
the VANTAGE PDMS Version 11.6 Graphical Model Manipulation
Guide for details. Future work will provide further specialist
discipline-oriented Editors to support the workflow for engineering
design.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

1-1

Introduction

A new GUI for DRAFT, including a 3D view, to simplify the creation


and annotation of drawings.

The first service pack provided improvements, based on early use of some
of these new features, notably in DRAFT. In addition, there were many
enhancements made to ease migration of PML applications to PDMS 11.6
and the .NET environment.
PDMS 11.6.SP1 also shared technology with AVEVAs new VANTAGE
Marine Outfitting product.
PDMS 11.6.SP2 enabled the use of two new add-on products: Final
Designer 1.3 and Laser Model Interface. These both integrate PDMS
with a third party product.

Final Designer enables the use of AutoCAD as an alternative editor for


PDMS Draft drawings. Its use is described in its on-line help and in its
Getting Started with Final Designer manual.
The Laser Model Interface enables PDMS Design to link to third party
laser model software to enable the point cloud survey data to be
visualised, measured and checked for clashes.
PDMS 11.6.SP3 brings further refinements, particularly to the new
piping application, as well as various priority enhancements and
corrections. It also adds support for the updated release of Global,
version 2.4.
PDMS 11.6.SP4 brings further improvements, as well as various priority
enhancements and corrections. Particular attention has been paid to
performance of the system, and in particular graphical picking. This
document also notes a few refinements in Global, in its first service pack
since the release of version 2.4.
PDMS 11.6.SP5 is provided to consolidate defect corrections and to
support a further update to Global, Global 2.5. This has many GUI
improvements as well as a major boost to update performance please
see separate bulletin.

1.2

Summary of Changes at PDMS 11.6


The changes fall into 3 main categories:

The PDMS Application Framework, with its new .NET GUI. This
brings improved ways of integrating users GUI customisation.

PDMS Design, with its enhanced Design Explorer and a new Plant
Editor, for Piping & Equipment.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

1-2

Introduction

PDMS Draft, with its new .NET GUI, 3D View and provision for
integration with AutoCAD.

Further work has been carried out on support of international languages,


though further improvements are planned for future releases. Details
are given in chapter 8 of this document.
There are many other minor improvements throughout the product and
much of the documentation has been updated.

1.3

Summary of Changes at PDMS 11.6.SP1

*sp1*

The changes fall into 3 main categories:

PDMS Design, with a new Add to Drawlist tool bar to specify the
colour of objects added using the Design Explorer.

PDMS Draft, with improvements to the usability of the new 3D View,


including section planes, and implementation of UNDO/REDO.

The PDMS customisation environment (PML Forms & Menus) has


further improvements for the definition of user interface gadgets.

In addition, changes have been made to support new releases of the other
VANTAGE Plant Design products, notably:
VANTAGE Plant Design Router 2.4
VANTAGE Plant Design Global 2.3
VANTAGE Multi-Discipline Supports 11.6
Corrections and improvements for many issues raised by customers in
PDMS 11.6 and earlier releases are also included in the service pack.

1.4

Summary of Changes at PDMS 11.6.SP2

*sp2*

1.4.1 Support for Final Designer


The new VANTAGE Plant Design Final Designer product provides a fully
integrated AutoCAD editor for DRAFT, thus enabling its use on
drawings produced directly from the PDMS model.

1.4.2 Support for Laser Model Interface


This new product enables point clouds from laser surveys to be used in
PDMS Design, thus enabling them to be viewed, measured and clash
checked alongside the PDMS model. It requires the use of a third party

VANTAGE PDMS Version 11.6.SP5


User Bulletin

1-3

Introduction

system from the specialist survey company, with which it integrates


closely. The system is designed to be open, but is expected to become
available initially from BitWyse, Leica (Cyra), Mensi/Trimble,
Quantapoint and Zoller+Frhlich (Z+F). There is a reference manual
explaining the new commands associated with the interface, but for full
details it is necessary to consult the appropriate third party vendor.

1.4.3 Miscellaneous Improvements


Corrections and improvements for many issues raised by customers in
PDMS 11.6 and earlier releases are also included in the service pack.

1.5

Summary of Changes at PDMS 11.6.SP3

*sp3*

1.5.1 Piping application


In addition to correction of issues raised by customers in their use of
earlier releases of PDMS 11.6, there have been various improvements to
the usability of the piping application. These are noted in section 3.3.1.

1.5.2 Draft 3D view


A number of enhancements to the new 3D view in Draft, notably to the
use of stepped section planes. See section 5.4.1.

1.5.3 Support of Global 2.4


PDMS 11.6.SP3 supports the use of a new release of Global; use with
Global 2.3 is not supported. This new release uses additional features in
the Global daemon (2.4) to allow a number of significant enhancements.
These include several aimed at providing better feedback to users, as
well as some giving additional control of Global functions. The robustness
of the daemon itself has been improved to minimize the number of
occasions it needs to be re-started.
The new features in Global are fully documented in a release bulletin
and updated versions of its other manuals.
Please note that many of the features of Global 2.4 are also available in
Global 2.2.SP2 for users of PDMS 11.5, in conjunction with a new service
pack SP2 for the latter. However, those which depend on additional
database attributes are not available.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

1-4

Introduction

1.5.4 Miscellaneous Improvements


Corrections and improvements for many issues raised by customers in
PDMS 11.6 and earlier releases are also included in the service pack.
These are noted in section 11.5.

1.6

Summary of Changes at PDMS 11.6.SP4

*sp4*

This service pack addresses a number of points raised during the use of
earlier releases of PDMS 11.6, along with corrections to faults found
during testing and use of earlier releases of PDMS. Details of these
changes can be found in Section 11.6.
In addition, there are some additional features, which are summarised
here and described in more detail in separate sections of this document.
The sample projects have also been updated, to include a steel catalogue
for Australia & New Zealand (see Section 1.6.4) and a dictionary
database for MDS (MASTER/MDSDICT) please see Chapter 10.
SP4 is accompanied by updates of some of the add-on products, notably:
VANTAGE Plant Design Router 2.4.SP4
VANTAGE Plant Design Global 2.4.SP1 (see Section 1.1.1.1)
VANTAGE Multi-Discipline Supports 11.6.SP4 (see Section 1.1.1.2)

1.6.1 Pipe bending checks & sketches


Allow the designer to check that a given pipe spool may be manufactured
by a particular machine, if such a machine has been defined in the
database. These pipes may then be detailed for fabrication using scale
drawings complete with fabrication information. Please see Sections 3.15
and 5.8.

1.6.2 Parameterised Property Attributes


This allows attributes in the property database to use parameters in
their definition, which can simplify the calculation of properties such as
weight. Please see Chapter 6.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

1-5

Introduction

1.6.3 Weights on Isometrics


This allows the user to add a weight column to the isometric material list
and provide a summary total for the fabrication and erection materials
plus an overall total for isometric material weight. Please see Section 4.7

1.6.4 Australian Steel Catalogue


This is a new catalogue in the standard project, structured in a similar
manner to the AISC one. Please see Chapter Error! Reference source not
found..

1.6.5 Intellectual Property protection for PML applications


A separate utility is available to encrypt PML macros. Encrypted macros
are automatically detected and decrypted as required. Please see Section
8.6.

1.6.6 Changes to related products


1.1.1.1 Global 2.4.SP1
Improvements to the user interface include:

Remote database session querying in ADMIN

Transaction purging appware in ADMIN

In addition, Network status is now available in all modules. Please note


that there are also corrections noted in section 11.6.1.
1.1.1.2 MDS
MDS 11.6.SP4 provides an interface to the design applications provided
by various pipe support vendors: Lisega, Carpenter & Paterson, Pipe
Supports Ltd. Please refer to MDS documentation for details.

1.7

Summary of Changes at PDMS 11.6.SP5

*sp5*

This service pack addresses a number of points raised during the use of
earlier releases of PDMS 11.6, along with corrections to faults found
during testing and use of earlier releases of PDMS. Details of these
changes can be found in Section 11.6.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

1-6

Introduction

In addition, there are many enhancements to Admin, mostly aimed at


simplifying the use of Global. The changes mean that it is important to
use Global 2.5.

1.7.1 Isodraft Enhancements


Significant Isodraft enhancements have been made since PDMS
11.6.SP4; they were first issued in PDMS 11.6.SP4.11.

SKEY Enhancements

Improved Continuation Sheet Functionality

Alternate Placing of Dimension Labels

These are documented in sections 4.9, 4.10, 4.11.


A further enhancement was included in PDMS 11.6.SP4.12.
Control component dimensioning on either side of a weld
This is documented in section 4.12.

1.7.2 Changes to related products


1.7.2.1 Global 2.5
Global 2.5 has many improvements, notably to update performance and
to the handling of offline satellites.
Please note that the performance improvements have necessitated a
change to the format of the data passed between locations, so 2.5 cannot
be mixed with versions of 2.4.
1.7.2.2 PDMS Nuclear Applications
There are two new product options available with PDMS 11.6.sp5:
Nuclear Concrete Design and Nuclear Room Manager. At present, these
applications are shipped and documented separately.

1.8

Documentation

*sp1* *sp2* *sp5*

This bulletin outlines the major changes at both the original PDMS 11.6
release and its service packs: it is updated for each service pack.
Most of the manuals were updated for PDMS 11.6; many had significant
changes that are noted on a Revision History page at the front of the
manual.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

1-7

Introduction

The Pipework design using VANTAGE PDMS manual, which was not
included in the original release, was updated for PDMS 11.6.SP1. The
following manuals were also updated for SP1:

PDMS Installation Guide

Drawing Production Using VANTAGE PDMS 11.6

PDMS Software Customisation Guide

PDMS Software Customisation Reference Manual

Many of the other manuals had minor amendments and corrections.


For PDMS 11.6.SP2, there were again amendments to 4 manuals:

Drawing Production Using VANTAGE PDMS 11.6

PDMS DESIGN Reference Manual Part 1:General Commands 11.6

PDMS ISODRAFT User Guide 11.6

PDMS ISODRAFT Reference Manual 11.6

The release also contains updated Design and Draft online help files:
updates were also supplied as a fix release PDMS11.6.SP1.2.
PDMS 11.6.SP5 also includes updates to some of the manuals, notably
for Admin.

1.9

Operating System and Hardware Environment

*sp4*

PDMS 11.6 is supported for use on Microsoft Windows 2000 SP4 and
Windows XP Service Pack (SP) 1, 2 or 3. It is not supported on the new
Windows Vista please see section 1.13 below. There is no UNIX version
of PDMS 11.6.
Windows XP SP2 requires changes to the default settings. The Internet
Connection Firewall (ICF) should be turned off or configured to enable
access to the database & licence servers. In addition, Group Policy
changes (which alter the registry) are required for users of Global
projects to ensure that RPC requests do not require authentication.
Details are given in the Installation Guide.
PDMS 11.6 requires Microsofts .NET Framework 1.1, which is supplied
on the CD-ROM and installed if required. This is used for the PDMS
graphical user interface. Please note that PDMS 11.6 is not compatible
with .NET Framework version 2.0 or later; if later versions are required
for other applications, it is necessary to install them in addition to
version 1.1. Further information is available on Microsofts web-site, for
example, see http://msdn2.microsoft.com/en-us/library/s80xxs7s.aspx.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

1-8

Introduction

PDMS 11.6 should run successfully on Windows NT4, but it has not been
tested under Windows NT4 and is no longer supported in that
environment. Please note that Microsoft no longer offers mainstream
support for either Windows NT4 or Windows 2000; it no longer offers
even extended support for NT4.
A minimum of 512 MB of memory is recommended for this release.
PDMS 11.6 will operate with less, but system performance will be
compromised. A screen resolution of at least 1024x768 is recommended.
Users running Windows XP are recommended to use the XP rather than
Classic theme. These should be set using Display Properties.
Due to the rapidly changing list of hardware-accelerated OpenGL
graphics cards commercially available, an up-to-date list of supported
graphics cards is not included in the documentation released with PDMS.
However, the AVEVA Web pages (http://www.aveva.com) contain a
current list of both tested and supported graphics cards.

1.10 Upgrading from previous releases

*sp5*

PDMS 11.6.SP5 is fully compatible with earlier releases of PDMS 11.6


and requires no upgrade. Please note, however, that Global should be
upgraded at the same time see above. PDMS 11.6 itself requires no
change to the PDMS database structure from that used at PDMS 11.4 &
11.5. Upgrade scripts are provided to upgrade projects from all previous
releases of PDMS 11 on the Windows platform, i.e. 11.2, 11.3, 11.4 &
11.5.
The upgrade scripts take account of a change at PDMS 11.4SP1, when
the standard database definition files were moved to the PDMS
executable directory (PDMSEXE). This simplified the upgrade process
required to add new attributes and elements to databases. It is no longer
necessary to copy these files (also known as virgin database files) to the
project data areas in order to gain access to new elements and attributes.
Users own PML customisation and applications from PDMS 11.4 or 11.5
should continue to work, after being amended to use the new application
switching mechanism. Please see Customisation chapter 8. It is possible
that some form layouts will be adversely affected by the change to the
standard Windows proportional screen fonts, though this depends on the
way the forms have been defined. There is also scope for enhancement
by using the new facilities offered by PML, such as toolbars and docking
forms. Many of the AVEVA applications have been upgraded in this way,
so users who have revised the AVEVA applications should review their
changes in the light of this work.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

1-9

Introduction

1.11 Compatibility

(update) *sp3*

PDMS 11.6.SP3 AutoDRAFT and DXF output functions have been


designed and tested with AutoCAD 2004, 2005 and 2006. Final Designer
(version 1.3) is compatible with AutoCAD 2005 and 2006.

1.12 Notice of change in support status

(update) *sp4*

1.12.1 PDMS 11.4 and earlier


PDMS 11.4 changed to inactive support status in June 2006, which
means that it is not normally be supported with releases of any kind.
At the same time, all earlier versions were withdrawn, which means
that customers no longer have the right to use them. In exceptional
circumstances AVEVA may be prepared to negotiate continued use and
critical problem support.
Full definitions of support status can be found on
http://support.aveva.com/support/United_Kingdom/index.htm in the
section on PDMS releases.

1.12.2 PDMS 11.5

(update) *sp4*

PDMS 11.5.SP1 was superseded by 11.5.SP2 during summer 2006. It was


accompanied by an updated version of Global, 2.2.SP2: both should be
used together and are fully supported, with previous versions of 11.5 now
at inactive support status.

1.13 Future considerations


1.13.1 AutoCAD integration

(update) *sp4*

Final Designer interfaces with AutoCAD and may provide an improved


method of performing some of the older AutoDRAFT functions. However,
there is no longer any plan to withdraw AutoDRAFT. The DXF output
feature is also unaffected, though it may be less necessary in future.

1.13.2 Windows versions

(update) *sp5*

Microsoft Vista is not supported for PDMS 11.6: it is a major upgrade


and will require some significant changes, at least to installation
procedures. AVEVA has investigated the implications and will support it
VANTAGE PDMS Version 11.6.SP5
User Bulletin

1-10

Introduction

for PDMS 12.1.SP1 (target May 2009) and subsequent releases. We will
drop support of Windows 2000 at the same release. Almost all
development at AVEVA is now carried out using Windows XP (service
pack 1, 2 or 3), which is currently the preferred option.
PDMS 12.0 also requires the installation of Microsofts .NET Framework,
in this case version 2.0. We expect to be using later versions of .NET for
subsequent releases.

1.13.3 Use of UNIX servers

(update) *sp5*

AVEVA has been supporting the use of Samba on IRIX servers to allow
users the opportunity to use their old servers for an interim period. This
is still supported for PDMS 11.6 but is not supported at the next major
release, PDMS 12.0, because of changes to allow larger PDMS databases.
Testing for PDMS 11.6 has used Samba 2.2.8a.

1.13.4 PML features

(update) *sp5*

Various changes are included in the next major release, PDMS 12. The
improvements to provide a more powerful customisation environment,
which complies better with Windows standards, mean that certain older
features can no longer be supported and will be removed: this may well
necessitate changes to some users PML applications. Those writing PML
applications should particularly note the following:
1.13.4.1

RADIO gadget

This gadget has been deprecated and has not been documented for
several years. It is no longer available in the PDMS 12 release. Any
usage should be replaced by the new FRAME and RTOGGLE gadgets,
which include its features and should offer a simple upgrade path.
1.13.4.2

RGROUP gadget

The RGROUP gadget, which replaced the RADIO gadget, has itself been
superseded by the radio group capability of the FRAME gadget in
conjunction with RTOGGLE gadgets. It still exists and continues to
work, but its use is discouraged; it will be removed in a future release.
1.13.4.3

Toolbar based OPTION gadget field reselection

Reselection of the selected field of an Option gadget on a toolbar will no


longer constitute a change of value. This provides better conformance
with expected behaviour in a Windows style GUI. The effect is that the

VANTAGE PDMS Version 11.6.SP5


User Bulletin

1-11

Introduction

gadgets SELECT call-back will not be run (a SELECT event is NOT


notified to PML).
1.13.4.4

Form based OPTION gadget field reselection

Reselection of the selected field will no longer necessarily constitute a


change of value. There will be an optional attribute NoReselection,
which is the recommended behaviour (as for Toolbar option gadgets
above). However, the default is Reselection, for upwards compatibility.
1.13.4.5

LIST gadget field Reselection

Reselection of the selected field no longer necessarily constitutes a


change of value. There will be an optional attribute NoReselection,
which is the recommended behaviour (as for OPTION gadgets above).
However, the default is Reselection, for upwards compatibility.
1.13.4.6

SAVE and RESTORE using .bin files

Binary save and restore is to be replaced by the combination of session


layout serialisation files and view content (.disp) files.

1.13.5 Design Comparison with Schematics

*sp5*

PDMS 12 offers a new option for integration and comparison of 3D


designs with schematic diagrams, such as P&IDs, from a variety of
systems. This initially covers equipment, piping, and HVAC and will be
extended in future to cover electrical cable. As a result, the old Design
Compare option (Compare module) has been removed.

1.13.6 ISODRAFT symbol files

*sp5*

PDMS 12 has a change to the format of ISODRAFT symbol files


generated by DRAFT. Those used in version 11 or earlier will not be
readable by ISODRAFT, so they will need to be regenerated from the
DRAFT database. Manually created symbol files are not affected.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

1-12

PDMS GUI General changes


PDMS 11.6 uses the Microsoft .NET environment including WinForms
based user interface components. Using this state-of-the-art technology
enables docking forms and toolbars in PDMS and provides a robust
foundation for the future provision of standard application programming
interfaces.
All modules with a graphical user interface (GUI) now use this new
technology, which is presented in an Application Framework and has
several new or updated components. The use of docking windows and
toolbars means that PDMS will appear more familiar to users of
Microsoft Windows XP and Office and reduce the number of dialogs
obstructing the 3D graphical view, enabling more effective use of screen
space. Many windows are now resizable, simply by dragging their edges
or corners in the usual Windows manner.
PDMS 11.6 also enhances the database explorer and drawlist with the
addition of filters and a more intuitive interface and at SP1 a colour
picker for objects dragged from the explorer.
The use of .NET has a significant impact on the number of program files
that comprise each PDMS module. For example, Design now consists of
the following files: des.exe, des.dll, wrappers.dll and these make use of a
large number of other files, including a large number of other .dll files.
This will have an impact on the way that bug fixes are issued: in future,
it is likely that fix releases will be cumulative. For example, fix release
11.6.0.5 will include all the changes in the preceding 4 fix releases.
Further information is given in the PDMS Installation Guide.

2.1

Glossary
The new Application Framework introduces some new concepts and
terminology, which are introduced here, along with other terms used in
this document. PDMS terminology is covered in the Getting Started with
PDMS manual.
Add-in

An add-in provides a means of adding functionality.


An add-in application appears on the Applications
menu, which provides a method of switching to it.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

2-1

PDMS GUI General changes

CE

Current Element the single PDMS object that is


acted upon by the PDMS command line and by many
of the user interface gadgets. See Selection.

Combo box

Standard Windows control that combines a text box


and interdependent list box.

Culture

The .NET term for the various local settings for


language etc. similar to the Windows locale.

Docking

This describes windows and menu bars that can be


attached in appropriate places to the frame of the
main PDMS window.

Dockable
Drag-and-drop

Select with mouse and then drag (holding the mouse


button down) to a different place.

Form

Input window see window.

MDI

Multiple document interface: a set of child windows


constrained to a single primary or parent window.

Menu bar

A horizontal bar below the title bar containing menus.

My Data

A new storage area for remembering PDMS data for


future use. Typically used for IDLists to copy from
one module to another.

Selection

Many of the user interface gadgets can now work on a


selection of objects defined using the 3D graphical
view.

Shortcut menu

This context sensitive pop-up menu is activated by


use of the secondary (usually right-hand) mouse
button.

Tab control

Allows multiple, usually related, forms (windows) to


be overlaid, with a simple switching mechanism
similar in appearance to a notebook or file divider.

Tabbed form
Title bar

The top, containing a title, of any particular window,


which can also be used to drag the window.

Toolbar

A frame containing controls, typically icons, to trigger


GUI actions

ToolTip

A small pop-up window containing descriptive text,


which typically appears when hovering over an icon.

Window

A separately controlled area of the screen. PDMS has


one primary or main window and many secondary
windows: some of these are often called forms.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

2-2

PDMS GUI General changes

2.2

Application framework
The PDMS 11.6 application framework provides the primary or main
application window with its associated main menu bar and toolbars as
well as support for docking windows. The framework also allows for
applications to be extended via the use of Add-ins, such as the Explorer,
and provides a GUI, based on the Microsoft Office 2003 look and feel.

2.2.1 Toolbars
The application framework supports toolbars, which can be floating or
docked to any of the sides of the primary window. Picking the title bar of
a toolbar and dragging away from the window frame will undock it.
Dragging it back to an appropriate place will re-dock it. The position and
state of toolbars and other windows are automatically saved between
sessions.
Note. Some toolbar tools cannot be displayed when a toolbar is docked
vertically.

2.2.2 Dockable Windows


The application framework supports the creation of dockable windows.
These may be dragged in a manner similar to toolbars and docked on any
side of the primary window. They may also be unpinned, so that they
auto-hide when not in use.

2.2.3 Floating Windows


Graphical views are contained in windows that can be floated via a
shortcut menu on their title bar. These floating windows can then be
placed on a different screen to the primary window.

2.2.4 Status Bar


The status bar consists of the following items:

An area for user prompts

A number of buttons to allow quick activation of MDI windows.

Current Date

Current Time.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

2-3

PDMS GUI General changes

2.2.5 Session Settings


Various user interface settings for each PDMS module are automatically
saved in files in the directory defined by the PDMSUSER environment
variable. They can thus be restored on the next entry to that module,
even between PDMS sessions. These settings can safely be reset to the
default value by deleting the relevant file. This process is called
Serialisation in Microsofts .NET environment and includes:

Layout of windows including their docking state

Explorer Settings

Element History including the CE

In general, the position and state of forms will be saved on exit from a
module and restored next time the user enters the module. This does not
apply to the contents of the main windows such as the 3D view, for which
the existing display binary save and restore mechanism may be used.
There are other exceptions: for example, the 3D view is not shown in
Draft until required, though its position is saved.

2.3

Tabbed Graphics form


The user interface for Graphics has been completely overhauled using a
standard Windows tabbed dialogue form to replace the original forms.
Many minor improvements have also been incorporated.
The new Graphics Settings form contains options previously on the 3D
View Options, Colours, Representation, Steelwork Representation, P-line
Representation and P-point Representation forms.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

2-4

PDMS GUI General changes

The Load Settings and Save Settings buttons load from and save to the
options files stored in %PDMSUSER%.
The Design bar menu has been changed to remove references to old
forms and to call the new one. The Graphics Settings form is accessible
from Settings > Graphics

2.4

Database Explorers
Explorer views have now been extended from the Design Database to
cover other modules and databases. The Application Framework
manages their layout and dockability. They provide a consistent tree
view of each database and module specific context menus.
An important feature of the Explorers is the ability to allow flexibility in
the presentation of the database hierarchy through the use of filters.
These are different sets of filters for different Databases. Additional
filters and other Explorer options are available on an Explorer Settings
form. The user may Drag-and-drop elements within and outside the
Explorer.
There is now a separate Toolbar Add-in, which shows the current
Element History.
Explorers are available in the Design, Draft, Spooler and Isodraft
modules, and replace the PML-based Members Lists. They are available
from the Main Menu>Display menus in each module. Each Explorer is
restricted to Elements of a particular database type.

2.4.1 History
The History Add-in appears on the main toolbar in Design, Draft, Spooler
and Isodraft. It displays the current element (CE), regardless of the
database.

The user can set the CE either by typing the element name into the
combo box, selecting a previously typed in element from the drop-down
list, navigating through the CE history one element at a time using the
backwards and forwards buttons or by selecting elements from the CE
history list using drop-downs on the backwards/forwards buttons.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

2-5

PDMS GUI General changes

When typing into the combo box the system attempts to auto complete
the name by scanning the open databases for the first 15 matches and
displaying them in a pop-up list. The user can then either carry on
typing or select an element from the list. When docked vertically the
toolbar displays only the backwards and forwards buttons; the combo box
is not displayed.

2.4.2 Explorer Settings


The Explorer Settings form is used to configure the behaviour of the
Explorer and set additional filters. It can be found, where appropriate,
from the Main Menu: Settings > Explorer
The settings are remembered between sessions for each user and module.
All options are turned off by default apart from Expand to CE which
causes the Explorer tree to expand, if required, to show the CE whenever
the CE changes. A very useful option is Auto Collapse Tree, which
applies to all active Explorers. If this is on, any expanded node not
containing the CE is collapsed whenever the user changes CE.
The remaining options apply to either the Design Explorer or the Draft
Explorer. They control the visibility of elements: they can set elements
as always hidden (e.g. non-writeable Template Worlds and LIBYs) or
allow previously hidden elements to be shown in the hierarchy (e.g.
TUBI, ROD and Point Worlds).

2.4.3 Filters
A predefined set of database filters is available to reduce the volume of
information presented in the Explorers. These can be selected and
turned on and off from each Explorer. When filtering is off the complete
database hierarchy is displayed in the Explorer. Only one system filter
can be active at any given time for each Explorer. Additional preset
filters are provided via the Explorer Settings Form (see above) for
special case elements. These can be toggled on/off regardless of
whether the system filters have been set.

2.4.4 Copy rules


An element (source) may be copied within the Explorer either by Dragand-drop, context menus or the keyboard shortcuts CTRL+C / CTRL+V
either beside or below another element (target). Paste beside copies the
element after the target.
For a copy to be valid the following must be true:

VANTAGE PDMS Version 11.6.SP5


User Bulletin

2-6

PDMS GUI General changes

The relevant MEMBER attribute is settable: with that of the target


element (if below) or its owner (if beside).

The source element type is an allowable member type for its new
owner.

If either of these rules is broken, the Paste is invalid. TUBI elements


cannot be copied or moved since they are implied by the system.
Users may add their own additional checks by adding code to the
following PML function:

IsCreatable.pmlfnc

This logical function is stored in %PMLLIB%\common\functions


directory and is called before the Copy.

2.4.5 Drag-and-drop
The Explorer supports Drag-and-drop within the Explorer to copy
elements, Drag-and-drop into the 3D view to add elements to the Draw
List and Drag-and-drop into My Data to add elements to it.
2.4.5.1 Drag-and-drop within the Explorer
Selecting an element and dragging it, with either the primary or
secondary mouse button down, initiates Drag-and-drop.

Single elements may be moved or copied within the Explorer using


Drag-and-drop (apart from TUBI if they are shown)

Copy rules are applied to validate the Copy (see above)

Hovering over a node causes it to auto-expand.

The mouse pointer icon changes to notify the user of an invalid copy
(e.g. between databases)

All child elements are transferred with the dragged item.

The Drag-and-drop action can be cancelled by pressing ESC at any


time before dropping.

A divider bar appears between elements to show where the dragged


element will be inserted if dropped, i.e. before, after or below.

Dropping directly onto an element assumes that the dragged


elements are to be added to the beginning of the elements child list.

Pressing CTRL whilst dragging performs a copy action.

Copy Drag-and-drop is indicated by an arrow + plus icon.

Copied elements and all their child elements are copied.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

2-7

PDMS GUI General changes

All connectivity attributes are lost in the copied elements.

The names of all copied elements which are named are prefixed with
Copy-(n)-of- (including copies of copies) where n >=2 (the first copy
will have the prefix Copy-of-.

Copy and Paste are available on the Explorer context menus.

After selecting an element and doing a Copy, the user may select a valid
owning element and add the Copied element to it using Paste or select a
valid sibling element and insert the Copied element after it using Paste
Before or Paste After. Paste is greyed out if the Copy is invalid

Alternatively the user can perform Drag-and-drop with the secondary


mouse button down. On mouse up, a context menu appears from
which the user can select a valid Copy or Cancel.

Finally, the user can use the CTRL+C and CTRL+V shortcuts to Copy
and Paste respectively.

2.4.5.2 Drag-and-drop into the 3D view


This allows the user to add elements in the Explorer to the Design
drawlist by Drag-and-dropping from the Explorer to the 3D view.

The user can select only single elements for drag & drop.

All significant elements will be added to the drawlist along with the
dragged element.

The elements can be dropped anywhere within the 3D view.

Elements cannot be dropped into place; they will appear in their


correct 3D positions.

The mouse pointer icon changes to notify the user of invalid moves

The Drag-and-drop action can be cancelled at any time before


dropping, by pressing ESC.

2.4.5.3 Drag-and-drop into My Data


This allows the user to add elements to My Data by Drag-and-dropping
from the Explorer into either the Collections or Contents grids in My
Data (q.v.)

The user can select only single elements for Drag-and-drop.

Dropping into My Data is equivalent to the Add to My Data context


menu.

Depending on where it is dropped, the dropped element is added


either to an existing Collection or as an orphan

VANTAGE PDMS Version 11.6.SP5


User Bulletin

2-8

PDMS GUI General changes

Child elements will not be added to My Data.

2.4.6 Mouse Actions


Primary mouse click:
Selects element, sets CE, (also expands/contracts tree if on node icon)
Primary mouse double click:
Selects element, sets CE, expands/contracts tree below element
Secondary mouse click:
Selects element, sets CE, displays context menu.

2.4.7 ToolTips
Name, Type and Description are shown in ToolTips over each Element.

2.4.8 Updates
The Explorers are kept in step with the database and CE. So, whenever
the user does the following the Explorer is updated:

2.5

Change CE

Create/Delete element

Rename element

Reorder / Include element (Copy/Paste)

UNDO / REDO

Getwork

MDB Update

Claim

Anything else that changes the state in the Explorer.

Drawlist
The Drawlist at 11.6 is a separate dockable window, managed by the
application framework, and replaces the previous Drawlist, which was
part of the Explorer.
It appears only in the Design and Spooler modules and provides
information about all elements currently added to the 3D View. It allows

VANTAGE PDMS Version 11.6.SP5


User Bulletin

2-9

PDMS GUI General changes

modification of the visual properties of the displayed elements, such as


visibility, translucency and colour. It also allows the user to add selected
Elements to My Data either from context menus or Drag-and-drop.

2.6

My Data
The My Data Add-in is a dockable window, managed by the Application
Framework, which provides a place for users to gather, organise and
perform operations on all the data they require to complete their tasks.
It contains collections of PDMS database Elements and single Elements.
My Data is particularly useful for the transfer of Design Drawlist
elements into Draft for the population of Drawings.
The user can add items to My Data in a number of ways: via context
menus on other components or via Drag-and-drop from other
components. The contents of My Data are persistent and are
reconstructed each time the user logs in. It is available in Design, Draft
and Spooler modules from the Main Menu>Display menus.
It consists of 3 components, namely a Collections Grid, an Actions Group
and a Contents Grid. The Actions Group and Contents Grids are
collapsible.

2.7

UNDO / REDO
The operation of UNDO and REDO has now been extended and is now
available to PML programmers for use in their applications. For details
of the latter, please refer to PDMS Software Customisation Guide section
8.3.7 UNDO and REDO.
Please note that UNDO is not yet available in modules other than
DESIGN & DRAFT.

2.8

Information about Global network status

*sp4*

It is now possible to Query the communications status of remote Global


locations in Design, Draft and Spooler. A form similar to that for
Remote > Locking and Isolation in Admin allows the user to query
Communication status and Project Lock and Isolation.
These queries are available from the Query menu:

VANTAGE PDMS Version 11.6.SP5


User Bulletin

2-10

PDMS GUI General changes

They result in the following forms, which behave in a manner similar to


the admin forms.

The user can ping locations by selecting them and using the Apply button
and then Sort and Filter results. Results are appended until the Clear
Results button is pressed.

The user can check locations by selecting them, toggling Lock, Isolation
or both and pressing the Apply button. The status will be displayed
below.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

2-11

PDMS Design Changes


The Locator Handle, which manipulates the 3D model, has been
enhanced to work in a variety of ways in a context sensitive manner.
The new Piping editor includes a Pipe Routing Handle. Piping designers
can route pipes interactively by dragging this Handle in the 3D graphics
view and snapping to element features. The interface includes extensive
graphical feedback to assist the designer and makes the pipe routing
process easy to learn and use, and very quick in operation.
The Locator Handle also provides features specific to piping components.
For example:

constraining the movement of piping components to the route of


the pipe

intelligent connection to nozzles and other piping components

moving groups of connected piping components.

Piping designers can now create piping components through a new


interface that uses docking windows to improve use of screen space. The
new interface allows rapid creation and placement of components in a
highly intuitive way, by interacting with the 3D graphics view. They can
also produce check isometrics (on screen or paper) from within Design,
thus simplifying the process of ensuring that the correct documentation
will be produced.
PDMS 11.6 extends graphical interaction to primitives below equipment
and sub equipment, thus enabling the manipulation of, for example,
nozzles using the Locator Handle.
In addition, many of the Design forms have been improved by using the
new facilities of the PDMS Workspace, such as tabbed forms.

3.1

General GUI improvements


Many forms in Design have been improved, for example:
The Query form is opened by selecting Query > Attributes from the main
bar. It has been made docking and resizable to allow easier viewing of
query results. The Query > General form has been removed.
The Query Project form is a tabbed form that replaces the existing User
List, Team List, DB List, MDB and Stamp List forms. It contains a tab

VANTAGE PDMS Version 11.6.SP5


User Bulletin

3-1

PDMS Design Changes

that shows the information that was previously shown on each individual
form.
The alpha view in the Data Consistency Check form no longer receives
the I/O requests channel when its not needed. The layout of the forms
has been improved.
The View Control form has been made dockable the menu bar has been
replaced by buttons, with some of the functions, changing the
background colour of views and deleting views, available on a shortcut
menu.
The layout of the Report Template form has been tidied up and tabs are
now used instead of spaces to align columns in the list. After input from
users, minor changes have been made: the form is not closed when a
report is saved; the user is asked to confirm before overwriting the
current data when modifying/creating a report; the user is asked whether
they want to quit without saving the current template when clicking on
the close icon.
The Penetration Defaults form now uses tabs for its three sections.
The Template Browser form has been made dockable. If open when
Design exits, its now opened when Design restarts. The Control > Select
CE TMPL menu option has been replaced by the CE TMPL button and
the Display > Selected Template has been replaced by the Display
button.
A new form, Data Access Control, has been created to replace the User
Rights form and add information previously found only on the Element
Data Access Control (DAC) Errors List form in the Model Management
product. The form has two tabs, displaying the information previously
shown on the two forms. The first, User Rights, shows the Access
Control Rights that apply to the current user, and information about
their scopes and roles. The second, Element Access, allows the user to
specify an element; for each attribute, it displays whether the user can
modify that attribute and the error message that occurs if not. It also
shows the operations (Claim, Issue, Drop, Create, Delete) the user is
allowed to carry out on that element. The form is shown by selecting
Query > Data Access Control from the bar menu.

Toolbars have been added to the Hangers & Supports application to


replace the current forms: the Utilities > Toolboxes > General and
Utilities > General > Support Creation menus now indicate whether the
toolbars are shown and toggle their visibility.
The Router forms, PDMS Router, Routing Messages and Branch Detail,
have been made resizable. This means there is no longer a need for a

VANTAGE PDMS Version 11.6.SP5


User Bulletin

3-2

PDMS Design Changes

means of resizing the forms by rebuilding them, so the forms associated


with that have been removed.

3.2

Element Selection

(update) *sp4*

Unlike PDMS 11.5, element selection behaviour is similar whether or not


Model Editor (Modify) mode is in use: the graphical selection set is
highlighted at all times. [Note: this selection set is not necessarily the
same as the Current Element or the object highlighted in the Explorer.]
The highlighting differs according to the elements Read/Write status: the
default edge highlighting being Dashed Green for Read/Write and Dotted
Red for Read only. When in Navigate mode (Model Editor not being
used), the selected objects cannot be changed, so all objects appear in the
Read/Write highlighting, even if they are Read only.
A more detailed description of selection is given in the Graphical Model

Manipulation Guide Chapter 2.

Model Editor button toggles between Navigate & Modify modes


There are two options for entering Modify mode. The first way is to click
on the Modify button; the second is to use the pull-down menu
Edit>Model Editor. The same two options are used to leave Modify mode.
When in Modify mode with object(s) selected, a handle appears on the
selection, which denotes the current interaction mode and guides the
user to possible operations. The most appropriate handle is chosen
whenever the selection changes. Where an alternative handle is
available, the pop-up menu will allow the user to change from (for
example) to a 3D handle from the constrained one.
The objects selected by a graphical pick depend on the application, the
Navigate/Modify mode and on various settings.

Navigate to Element button toggles Equipment selection level


This toggle is available in Navigate mode only: when selected, the pick
will select objects at equipment primitive level. When not selected, the
selection will be at Equipment level.
If you wish to edit the equipment, there is a further popup menu Edit
Equipment while in Model Editor mode see below.
In the piping application, related objects are selected by default. For
example, if a user selects a valve, the system by default selects the
flanges and gaskets connected to the valve. If only a single object is
required, the shortcut menu option Select CE can be used.
VANTAGE PDMS Version 11.6.SP5
User Bulletin

3-3

PDMS Design Changes

N.B. A status bar prompt (e.g. Identify Nozzle) appears when the system
expects a 3D pick. If you wish to escape from this, it is necessary first to
click in the 3D window.

3.3

Quick Pipe Routing


The quick pipe routing function allows the user to define the path of a
pipe wherever there is an ill-defined route within a branch, i.e. where the
dotted line is displayed instead of implied tube.
In defining a route the system will allow the user to perform the
following:

Orthogonal and non orthogonal leg definition

Positioning:
o Increment snapping
o Explicit positioning
o Feature snapping

Centre line

Offsetting by OD of tube (including insulation)

Automatic completion of route


o Where completion is predictable

UNDO/REDO changes

Where an extremity of a route is undefined, the system will allow the


user to assign the end to the last defined point within the route or to
designate an appropriate element to which the extremity is connected.
Note:
Where a component can not be selected from the spec, the shows a
blob to alert the user but does not display any other error alert.

3.3.1 Improvements for PDMS 11.6.sp3

*sp3*

Several usability improvements have been made to Quick Pipe Routing.


These include the following.
Connection errors are handled better.
The router tries to resolve the appropriate configuration of components
when it creates a component, e.g. creating a flange will try and create the
gasket as well. Under some circumstances, where the router cannot

VANTAGE PDMS Version 11.6.SP5


User Bulletin

3-4

PDMS Design Changes

connect and position a component with the minimum spool length, the
system will now return: Incompatible Connection error.
Set Branch option now sets the current spec of the branch into the form,
so that all component Selection is from the branch spec.
Equal size tees with PBOR3 set to E in the relevant column of the spec
no longer give a warning message.
See also fault corrections section 11.5.

3.4

Pipe Component modification


The pipe component modification function allows the user easily to rotate
or position a single component or selection of connected components
within the constraints of a pipe route.
In modifying a component or components, the system offers the following
functionality:
Rotation about the tube centre line
Constrained positioning along the path of the pipe route:
o Increment Snapping
o Feature Snapping
Components can only be repositioned where there is sufficient space to
fit them in the route
Automatic reorder of the elements within the hierarchy to suit the new
position within the pipe route
The ability to reposition the handle within the constraints of the
component selection set (along the centre line of the pipe)
The initial orientation of a selection is maintained where possible
UNDO/REDO of changes
The system does not try to resolve any inconsistencies that may occur
from the repositioning of a component, e.g. if a reducer is moved into
another leg of a branch, the components and tube between its original
position and new position in the branch will remain the same.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

3-5

PDMS Design Changes

3.5

Pipe Component creation


The new pipe component creation form allows the user to create a
component or component group that is either connected or positioned
along the route of a pipe.
The system will automatically try to create a set of predetermined
adjacent component types when certain component types are created, e.g.
creating a valve will try to create the appropriate adjacent gaskets and
flanges. This allows the pipe designer to define the major components of
the pipe route, with the system creating the secondary components
automatically.
Once a component (or group of components) has been created the system
will automatically select it, allowing the user, when in Modify Mode, to
modify the components position or rotation.

3.6

Pipe Component Reselection


Pipe components may be individually reselected using the reselection
form.

3.7

Equipment Editing
Equipment primitives may now be repositioned using the Equipment
editing mode of Model Editor. This involves drilling down the
hierarchy to the template, sub-equipment, primitive or negative
primitive required.
This mode can be entered by selecting an equipment item and using the
pop-up menu to pick Edit Mode > Equipment Editing.
To help selection, when an element in the equipment hierarchy is
selected it is drawn solid, together with its children, and the rest of the
drawlist is made translucent. When a positive primitive is selected, any
negative primitives that it owns are drawn in wireline, which allows
them to be picked: this would not be possible in HOLES ON mode.

3.8

Design Areas
These are 3D volumes encompassing a portion of the plant model. For
example, they might encompass a process or part process that can be
worked on in isolation. In some industries, they are usually regularly

VANTAGE PDMS Version 11.6.SP5


User Bulletin

3-6

PDMS Design Changes

shaped and aligned with major plant axes; in other cases, they are more
likely to be irregularly shaped, positioned and orientated.
New Design Database elements (top level AREAWL, AREASET,
AREADEF, ABOX, ACYLI, ACONE, ADISH, ASLCY, ACTOR, APYRA
and ASNOU) have been added for modelling Design Areas. These
primitives are defined in a similar manner to the normal equipment
primitives. Clash detection may be used to determine the contents of
these areas.

Which plant item origins are in a given Area?

For a given item, which Area(s) contain its origin?

Collections have been enhanced to reference Areas: some of the geometric


operations have been improved, including an EXCLUSIVE option for
WITHIN.
These Areas will be used in future PDMS applications and for improved
integration with VANTAGE Project Resource Management.

3.9

New Piping Pseudo Attributes


Several new pseudo attributes are now available for piping.

3.9.1 Branch Surface Area


BRIARE/A

Branch internal area.

BREARE/A

Branch external area.

These provide an approximate inside & outside surface area for piping
and are valid for PIPE, BRANCH, BRANCH members and SPOOL
elements. The following assumptions are made:

A Bend or Elbow is treated as a torus; any other Branch Element


is treated as a cylinder or cone.
If the CMPR on the SPCO is set, the OUTD (Outside Diameter) or
ACBO (Actual Bore) will be used, otherwise P-Arrive and P-Leave
bores and outside diameters will be used.
Insulation is ignored.

3.9.2 Range of Angles or Radii


RANANG/LE

Range of available angles. (Optional noun argument)

RANRAD/II

Range of available radii. (Optional noun argument)

VANTAGE PDMS Version 11.6.SP5


User Bulletin

3-7

PDMS Design Changes

These pseudo attributes, valid for branch and branch members, provide a
list of available angles or radii for selecting bends and elbows. The
information is derived from the branch PSPE and the bore of the
previous element in the branch (head bore if the first element). The
result comes from the ANGL or RADI, if appropriate or is returned
unset.

3.9.3 Data Consistency


This set of attributes gives a measure of the quality of the pipe route:
bores, connection types, offset and angle between a P-point and its
neighbour are checked.
AQANG

Angle between a branch component and its previous


component. Calculates angle between the P-point
directions and also with the vector between the Ppoints and uses the greater.
SPKBRK FALSE ATTAs are ignored

LQANG

Angle between a branch component and its next


component. Calculates angle between the P-point
directions and also with the vector between the Ppoints and uses the greater.
SPKBRK FALSE ATTAs are ignored

AQOFF

The offset between a branch component and its


previous component. Returned in distance units.
SPKBRK FALSE ATTAs are ignored.

LQOFF

The offset between a branch component and its next


component. Returned in distance units.
SPKBRK FALSE ATTAs are ignored.

AQCON

Returns true if the connection between a branch


component and its previous component is correct.
Is also valid when CE is TUBI.

LQCON

Returns true if the connection between a branch


component and its next component is correct.
Is also valid when CE is TUBI.

AQBORE

Returns true if the bore between a branch component


and its previous component is the same.
Does not consider TUBI.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

3-8

PDMS Design Changes

LQBORE

Returns true if the bore between a branch component


and its next component is the same.
Does not consider TUBI.

PQANG <int>

Angle between specified P-point of a branch


component and its adjacent component. Calculates
angle between the P-point directions and also with
the vector between the P-points and uses the greater.
SPKBRK FALSE ATTAs are ignored.
Attribute is valid for Branches. For branch members,
only the arrive & leave P-points are valid.

PQOFF <int>

The offset between specified P-point of a branch


component and its adjacent component. Returned in
distance units.
SPKBRK FALSE ATTAs are ignored.
Attribute is valid for Branches. For branch members,
only the arrive & leave P-points are valid.

PQCON <int>

Return true if the connection between a branch


component and its adjacent component is correct.
Is also valid when CE is TUBI.
Attribute is valid for Branches. For branch members,
only the arrive & leave P-points are valid.

PQBORE <int>

Return true if the bore between a branch component


and its adjacent component is the same.
Does not consider TUBI.
Attribute is valid for Branches. For branch members,
only the arrive & leave P-points are valid.

3.10 New Attributes for Material Management


The following attributes have been added, primarily to facilitate
integration with VANTAGE Project Resource Management (VPRM).

3.10.1 Status attribute for use in MTO output


A new attribute, FSTATUS, has been added to the following elements:
PIPE, STRU, EQUI, REST, ZONE, PCOM, ATTA, SPLDRG, SPEC
VANTAGE PDMS Version 11.6.SP5
User Bulletin

3-9

PDMS Design Changes

3.10.2 Additional attributes for spool MTO


The following attributes have been added to the SPLDRG element:
FAREA, FPLINE, FDRAWING, FREVISION, FRDRAWING

3.10.3 Additional attributes for Piping Specifications


The following attributes have been added to the SPEC element:
FISSUE, FINPUTBY

3.11 Extract Refresh


Modifications in PDMS can cause the Spatial map for an Extract to
change, resulting in the Map being updated on entry to Design. As a
result the User will now need to do a SAVEWORK to save the changes
before an EXTRACT REFRESH command can be executed.

3.12 Add to Drawlist tool bar

*sp1*

This enables the user to specify the visual properties of items added to
the drawlist, for example by dragging from the Explorer to the 3D view.
The options are Auto (rule-based) or Specific (colour, translucency and
edges on or off).

3.13 Piping component (e.g. flange) alignment

*sp1*

This development allows piping components to be connected so that by


default their Z directions are aligned. This is particularly useful for
ducting and cable trays etc. or where flanges need to be aligned. The
following changes have been made:

A PZAXIS attribute has been added to various ppoint elements in


the catalogue.
New pseudo attributes allow it to be queried in the design.
The connect command has been enhanced to use the PZAXIS if set.
Appropriate Datacon checks have been added.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

3-10

PDMS Design Changes

3.13.1 New attribute for PTCA, PTAX, PTMI, PTPOS


PZAXIS Z direction

3.13.2 New pseudo attributes for branch members

PZDIR Alignment direction for specified ppoint.

AZDIR Alignment direction for arrive ppoint.

LZDIR Alignment direction for leave ppoint.

PQAANG Angle between alignment direction for specified ppoint


and adjacent component.

AQAANG Angle between alignment direction for arrive ppoint


and previous component.

LQAANG Angle between alignment direction for leave ppoint


and next component.

3.13.3 Connection Command


The syntax of the command is unchanged, but it now uses valid
alignment directions in place of a default orientation. It checks that a
PZAXI is set for the relevant ppoint of the current element and for the
ppoint it is connecting to. If the element being connected to is a gasket or
a weld and does not have a set PZAXI then the ppoint of the next
element is used instead. If there are either one or two unset alignment
directions, then the connection command functions exactly as before. If
an orientation is specified, e.g. CONNECT AND P3 IS UP, then this will
override the alignment direction.

3.13.4 New Datacon warning messages


The following warnings can now be generated. They are not output if the
branch is badly routed.
D850 BAD ARRIVE ALIGNMENT GEOMETRY, ANGLE IS 15
D850 BAD LEAVE ALIGNMENT GEOMETRY, ANGLE IS 45

3.14 HVAC application new components

*sp1*

The range of components supplied with the standard application has


been increased.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

3-11

PDMS Design Changes

3.15 Pipe bending checks

*sp4*

PDMS 11.6.sp4 allows you to check pipe pieces and pipe spools for
production readiness against welding machines, bending machines, pipe
cut lengths on drawings and reports, and defined stock-lengths of tubing.
Fabrication checks run against available stock length and fabrication
machines.
Fabrication machines are currently limited to bending and auto
welding.
These checks rely on a number of changes to the Design database that
were introduced at PDMS 11.6.sp1. They were initially introduced for the
marine product.
Pipes designed and checked in this way may be detailed using the new
pipe-sketch facility but not yet with Isodraft. Please see section 5.8.

3.15.1 Definitions
Pipe Piece
A pipe-piece is the lowest level of fabricated item in the pipe. It relates to
a continuous piece of pipe tube that can be fabricated from stock
material.
The pipe piece holds references to the components at the start and end of
the piece. The system derives pipe-pieces: users cannot create or delete
them. Note that components on the end of the pipe pieces are not part of
the pipe piece, but are referenced by it.
Pipe Spool
A pipe spool is a prefabricated part of a pipe or branch, often welded
together in a workshop before being sent to the ship to be fitted on-site.
Pipe spools typically comprise a bent pipe with welded flanges at each
end, but they can also be more complicated fabrications with branches,
reducers and other components.
The system derives spools: users cannot create or delete spools. PDMS
11.6 does not include gaskets in the spool.

3.15.2 Design Database additions

(update) *sp4*

These elements were added to the database for PDMS 11.6.sp1, but were
unused until sp4.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

3-12

PDMS Design Changes

3.15.2.1

Design grid

New top level element GRIDWL: used for ship coordinate system but not
used in PDMS 11.6.
3.15.2.2

Fabrication machine definitions

New top level element FMWL.


3.15.2.3

Pipe pieces & pipe spools

New elements PPLIST (Pipe Part list) & PSLIST (Pipe Spool list).

3.15.3 Production Pipes Check Form


To check pipe spools for production readiness, you need to be in the
Design module and running the Pipework application. To display the
Production Pipe Checks form, choose the Utilities>Production Checks
option from the main menu bar.
If appropriate, you will be prompted to select a PIPE (using the Explorer
or 3D View) and then generate spools if this has not yet been done:

Once this is done, the main form will be displayed: it has five sections
that allow you to control different aspects of the production check on the
pipe and its spools:

Spools for the currently selected pipe

Tasks relating to the entire pipe

Tasks relating to the currently selected spool

Navigation relating to the currently selected spool

Options for setting up production checks.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

3-13

PDMS Design Changes

VANTAGE PDMS Version 11.6.SP5


User Bulletin

3-14

PDMS Design Changes

3.15.3.1

Pipe Tasks

Option

Function

Validate Pipe

Runs production checks against entire


pipe. The checks run for each spool in
the pipe that requires validating

View Production Information

Displays the production information


currently associated with each pipe
spool and pipe-piece

Remove Machine Info

Removes machine fabrication


information from all pipe spools and
pipe-pieces in the pipe

3.15.3.2

Spool Tasks

Option

Function

Validate Spool

Runs production checks against the


selected spool

View Production Information

Displays production information


currently associated with the spool and
its pipe-pieces

Remove Machine Info

Removes machine fabrication


information from the selected spool

3.15.3.3

Navigation

Option

Function

View Spool in Graphics

Sets up 3D View so the selected spool


fits in it

3.15.3.4

Setup Production Checks

Option

Function

Select Default Fabrication


Machines

Allows you to define the fabrication


machines to use when running
production checks against pipe spools

Define Auto-Resolve
Preferences

Sets options for automatically adding


any excess needed as a result of a check
against a bending machine

Define Stock Length

Sets up length used in checks

VANTAGE PDMS Version 11.6.SP5


User Bulletin

3-15

PDMS Design Changes

3.15.4 Setting up Production Checks


You run production checks against fabrication machines and tube stock
lengths you define using the options on the Setup Production Checks
section of the Production Pipes Check form.
3.15.4.1

Select Default Fabrication Machines

If a pipe-piece does not have a bending- or welding-machine associated


with it when the production checks run, the system checks the pipe-piece
against all machines selected in the default machine list. This allows the
system to identify and assign fabrication machines.
To define the default bending- and welding-machines to use in production
checks, click Select Default Fabrication machines. The lower pane displays
a selectable list of the available fabrication machines.

Select the machine you want to use and click Apply; if you want to cancel
the operation, click Back.
To avoid choosing incompatible machines, you can pick out fabrication
machines that can handle the pipe tubing in the selected spool. The
system checks the bore, material, and length of the tubes to see which
machines can handle the spool. To do this click For Spool x, (where x is the
number of the selected spool) and the lower pane changes to display a list
of the machines that can handle the pipe tube in the selected spool.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

3-16

PDMS Design Changes

Select the machines you want to use from the list and then either append
them to the current default machine list by clicking Append to Default
Machine List, or replace the entire list by clicking Replace Default Machine
List.

Clicking Back will take you back to the previous screen.


3.15.4.2

Define Auto-Resolve Preferences

To define auto-resolve preferences click Define Auto Resolve Preferences.


The lower pane changes to display the available preferences:
If you check Include End Excess the system adds excess pipe to the end of
the pipe-piece if needed. If you check Include Feed Excess the system adds
feed excess to the pipe-piece if needed.
3.15.4.3

Define Stock Length

The system checks the final cut length of a pipe-piece against the available
stock length.
To define the stock length click Define Stock Length. This opens an edit-box
you can use to change the stock-length value: Enter the new value then
click Apply to accept the value, or Back to cancel and reset the form to the
previous value.

3.15.5 Running a Production Check


To run a production check against every spool in the pipe you want to
validate, click Validate Pipe; to run the checks against a single spool, click
Validate Spool. These options run the production checks and show the
results in the lower pane of the form.
Production checks run using the fabrication machines associated with the
individual pipe-pieces of the spool.
If no machines are associated with a pipe-piece, then the system checks it
against all machines defined in the default machine list.
When the checks have run, the spool list at the top of the form displays the
results of the check for each spool. This can be one of the following three
states:

State

Meaning

Successful

Production checks were successful.

Failed

Some part of the production check failed.

Valid for production

Spool had already been validated so was not


rechecked.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

3-17

PDMS Design Changes

The lower part of the form shows the results for each pipe-piece of the
selected spool.
A list of pipe-pieces shows the production check results per piece, and each
piece has one of the three states above associated with it.
Selecting a pipe-piece from the list displays the detailed results of the
check below the pipe-piece list. The information displayed in this part of
the form depends on the results of the check. Some examples of different
results follow.
3.15.5.1

Successful Check with no Modifications

You will see this result where the check succeeded against both bendingand welding-machines, if these machines were required, and the pipepiece didnt have to be modified.
The results panel shows which, if any, bending machine was used and
which flanges, if any, can be pre-welded.
3.15.5.2

Successful Check with Modifications

In the different example below, you can see the check succeeded against
both bending- and welding-machines, and some excesses were needed to
make the pipe piece pass the checks.
As well as the bending and welding machine information there is a list of
excesses the pipe required. In the example above, you can see BM1 is
suitable for bending the tube, no flanges can be pre-welded, and both the
arrive and the leave of the tube required excesses. For each excess there is
a link-label for the type of excess.
If you click on this link the excess shows a tag in the graphics view so you
can see where it applies to the pipe-piece.
3.15.5.3

Failed Check with Modifications Required

If the pipe-piece requires excesses to pass the checks but you have set up
the auto resolve preferences not to include excess automatically, then the
check will fail. In this case the results display the excess required. You can
accept these excesses to make the pipe-piece pass the checks.
You can also set the pipe to be manually bent and so ignore bending
checks.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

3-18

PDMS Design Changes

3.15.5.4

Non Resolvable Failure

The pipe-piece may fail the production checks for a more serious reason.
For example, it may not be possible to find a bending machine that can
handle the pipe tubing the pipe-piece uses.
In this case the results panel shows the system cannot resolve the failure
by adding excess. To overcome this, you can set the pipe-piece to be
manually bent.
3.15.5.5

Stock Length Failure

If the pipe-piece also fails a stock length check then this is reported in the
lower part of the panel.
3.15.5.6

Expanding Machine Results Panel

You may be able to expand the bending machine and welding machine
results in the results panel, to display more information. If there is more
information to view then the Expand icon appears by the Bending Machine
Result title. Clicking the title or the icon expands the bending machine
results.
3.15.5.7

Modifying Production Information

You can also modify the production information applied to the pipe-piece.
Click Modify Production Information to display the required panel.
Use this panel to change the bending or welding machines and modify the
end excesses or apply minimum feed to a leg.
3.15.5.8

Changing or Assigning a Machine

To change or assign a bending or welding machine click the appropriate


link. If no machine is associated with the pipe-piece then Change bending
machine will read Assign Bending machine.
If the tube is straight, there are no bending machine options. If there are
no pre-welded flanges, there are no welding machine options.
Select the required machine then click Apply. To cancel any changes and
go back to the previous panel, click Back.
After selecting a new machine click Accept Changes at the bottom of the
panel to accept the changes.
3.15.5.9

Editing End Excess

To edit the end excess first expand the collapsible panel by clicking End
Excess.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

3-19

PDMS Design Changes

You can add your own end-excess by entering a value in the User Defined
text box.
Click Accept Changes to accept the new value.
3.15.5.10

Applying a Minimum Feed to a Leg

To view the feed excesses applied to a leg between two bends, click Feed
Excess to expand collapsible panel.

For each leg there is an editable text box in which you can enter a
minimum feed value for the leg. If you enter a new minimum feed value
for the leg then the system recalculates the feed excess the next time it
checks the pipe-piece.
3.15.5.11

Revalidating the Pipe Piece

After changing the production information you can revalidate the pipepiece by clicking Revalidate Pipe Piece. This runs a production check on the
pipe-piece with the new values.
3.15.5.12

Finishing Viewing Results

To finish viewing the results of the production checks click Finish Viewing
Results to return to the top level of the form.
3.15.5.13

Viewing Production Information

You can view the production information assigned to pipe-pieces of a spool


without having to go through a production check.
To do this, click on View Production Information for either the pipe or a
spool. This displays a view of the production information assigned to each
pipe-piece in the same way as does clicking on Modify Production
Information from the production check results panel.
3.15.5.14

Removing Machine Information

To remove all machine information associated with a pipe spool or all the
spools on a pipe click Remove Machine Info for either the pipe or the
selected spool:

3.15.6 Automatic Flange Alignment


For pipe-pieces and pipe spools that have been set up to be machinewelded, the system ensures it correctly orientates the piping model so
flange-holes and spools align when assembled.
The system checks flange-alignment as part of the pipe-checking and
Datacon functionality.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

3-20

PDMS Design Changes

3.16 Laser model and its manipulation

*sp2*

These options are only useful when the new Laser Model Interface is
installed. Details are available in its documentation.
The links to this external geometry are stored in new database elements
XGEOM, XLCTN, XCELS.
This enables the point cloud model to be visualized, measured and clash
checked alongside the PDMS model.

3.17 Check Isometrics


Check Isometrics can now be produced from within Design and Spooler.
Extra syntax has been added to the command line:

Isodraftmode switches into the Isodraft syntax.

Exit returns the user to the Design/Spooler syntax.

The Utilities menu has been extended in the Design Pipework discipline.
(A similar capability has been added to the Spooler module). Selecting
Pipe Isometric or System Isometric at a Pipe, Branch, Spldrg, Spool
or Field element will display a preview isometric (processed using a
predetermined options file, which may be replaced by the user). There is
a button to display the process time messages.
Selecting Show Pipe System at a pipe or branch element will highlight
the connected system for that element in the 3D view.
A Windows printing mechanism is also provided: it is possible to print
or all sheets using . There are similar icons for
single sheets using
previewing single or multiple drawings and for saving them to file.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

3-21

PDMS Design Changes

3.18 Look Explicit

*sp3*

The Explicit view direction option has been reintroduced in Design, on


the Limits CE Options popup menu. The user can enter the required
angle for the view direction, for example looking along a structural
member.

The Look 3D View form has a popup menu for setting view direction;
this allows the user to use the orientation of picked graphical items to
populate the Direction field.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

3-22

Piping Isometric Enhancements


In addition to the new check isometric facility in DESIGN and
SPOOLER, a number of improvements have been made to the
ISODRAFT module, some involving data set up in other parts of PDMS.
They are listed here for convenience.

4.1

General GUI improvements


ISODRAFT has a new Office 2003 style GUI, based on Microsofts .NET.
This includes many new features such as window and toolbars docking,
tabbing etc. Please refer to section 2.2 Application framework for further
details.

4.2

Parameterised MTOL & MTOQ


It is now possible to parameterise MTOL & MTOQ for example, the
following is now possible:
MTOQ (PARA[3] + DESPAR[2] )

4.3

Use of temperature and pressure for selection


The temperature and pressure attributes from the owning branch can
now be used as Spec selectors for choosing bolting items in ISODRAFT.
Spec answers may use a specific value or give a range.

4.3.1 Standard Bolt Hole DB Change


The bolt set BTSE now has some of the same attributes as a BLTP:
BTHK, BDIA, BTYP
as well as a new attribute:
NOFF (number off), which is defined as for the SBOL element.
If these entries are set, the program automatically creates an array with
NOFF members which are the default bolts for this connection.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

4-1

Piping Isometric Enhancements

This enables a drastic reduction in the amount of data that is required to


define bolt requirements. However, if the new attributes are not set, the
existing methods continue to work in exactly the same manner.
BLTPs should still be used as members of a BTSE for those numbers
where there is a deviation from the standard bolt as defined in the BTSE
or if the bolt hole numbering is non continuous. Note that Jacking bolts
must always be defined using BLTPs.

4.4

User-defined Material Lists


The restrictions on users defining their own material list format have
been eased. It is no longer necessary to be using the PARTNUMBERS
FROMDB option in order to do this. See MATERIALLIST command in
the VANTAGE PDMS ISODRAFT Reference Manual.

4.5

Spooler Pulled bend numbering

*sp1*

A new option has been added to the PARTNO command, for each of its
CREATE, CHECK and UPDATE <gid> options, e.g.
PARTNO CREATE <gid> PARTNO

This PBEND option (at the end of each command) will result in bends
having unique part numbers and will ensure implied tube either side of
the bend will have the same part number. Not all bends will be
numbered using this syntax; zero length bends will not be numbered.

4.6

Isodraft Pulled bend numbering

*sp1*

The syntax for PARTNO has been modified to include a new option for
pulled bends:
PBENDNUMBER ON PARTNO

This will use the part number rather than the bend number as the source
of the Bend number on the drawing and in the bend table if shown.

4.7

Weights on Isometrics

*sp4*

This new feature allows the user to add a weight column to the isometric
material list and provide a summary total for the fabrication and erection
material plus an overall total for isometric material weight.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

4-2

Piping Isometric Enhancements

4.7.1 User Interface


The user interface provides the following new options:
4.7.1.1 WEIGHT on the Material List Column Definition
The Material List Column Definitions form displays the option
WEIGHT in the list of available Component attributes.
4.7.1.2 Total Weight Option
If, and only if, this option is selected, three checkboxes are displayed: TOTAL FABRICATION

TOTAL ERECTION

TOTAL COMBINED

4.7.1.3 Weight Conversion Factor


In addition, a Conversion Factor (pre-populated with a value of 1.0)
may be specified.

4.7.2 Command Syntax


This mechanism generates the following syntax in the Options file:
Column c OTHER Heading 'WEIGHT' WEIGHT with Width www [TOTAL
FABRICATION] [TOTAL ERECTION] [TOTAL COMBINED] Factor f

4.7.3 OUTPUT

For the total weights, a new text element is optionally placed below each
material column.
All of the above texts have been given a text number and added to the
alternative text list so that they may be modified to a different language.
If a component does not have a weight, a --- character string is output to
indicate that no weight can be found.
The weight column and extra weight text is output to the
MATLISTFILENAME file if selected.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

4-3

Piping Isometric Enhancements

4.7.4 Example Material List

VANTAGE PDMS Version 11.6.SP5


User Bulletin

4-4

Piping Isometric Enhancements

4.8

Flow Arrow settings

*sp4*

Isodraft places flow arrows on the isometric with their direction governed
by the BRANCH attribute FLOWDirection. The function is controlled
using the FLOWARROWS command (please see ISODRAFT Reference
Guide). The arrows can be placed automatically or positioned using
ATTAchments with their ATTYpe attribute set to FLOW.
The settings for FLOWD are either BACK for flow from tail to head or
FORW for flow from head to tail.
Two new settings are now handled by Isodraft: OFF to allow the arrows
to be turned off or BOTH to indicate a two-way flow. Any other setting
will continue to be treated as forward.
Examples of 2-way flow arrows are shown below:

4.9

Isodraft SKEY Enhancements

*sp5*

4.9.1 New UNBW SKEY


A new SKEY UNBW (Butt Weld union) is now available. It has the same
GTYPE, Plotted Symbol and P-points as the existing Socket Weld and
Screwed Fitting Unions (UNSC and UNSW).

VANTAGE PDMS Version 11.6.SP5


User Bulletin

4-5

Piping Isometric Enhancements

4.9.2 New FY** SKEY


A new SKEY FY** (Y-type Filter/ Strainer with ** = BW, CP, SW, FL,
SC, PL) is now available.
P-points

Plotted
Symbol

This is in addition to the existing filter/strainer SKEYs FI**, FA**, FO**


and FR** with ** = BW, CP, SW, FL, SC, PL.

4.9.3 Tee/Olet SKEY Enhancement


Certain existing Tee/Olet SKEYS have been enhanced to allow the user
to indicate the presence of an offset P3.The P3 connection of the tee/olet
must be connected directly to a pipe/tube.
Affected SKEYs are HC**, TS**, Y1**, Y2**, Y3**
(with ** = BW, CP, SW, FL, SC, PL) and TPUL, TEBW, TESO, TERF,
TESW.
The default behaviour is that, if an offset P3 configuration is present, a
new ATEXT characterising the offset is output on the drawing. This new
ATEXT is number 233 in the list of ATEXTs and its default value is
BRANCH OFFSET BY followed by the nonzero relative coordinates of
the offset.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

4-6

Piping Isometric Enhancements

4.10 Improved Continuation Sheet Options

*sp5*

4.10.1 New Annotation Options

4.10.1.1

Show Coordinates across Sheets.

An extra clause SHEET has been introduced to the COORDINATES


command to specify that spatial coordinates are to be shown at sheet
breaks on the same isometric: Coords ON AT Sheet

This may be accomplished automatically by a new checkbox Sheets


option on the Annotation Options form (highlighted above as 1).
Checking this box will display the appropriate coordinates.
4.10.1.2

Continuation Sheet Information at Sheet Breaks

A new CONTSHEETS command is introduced which takes effect when


one isometric drawing is located on several sheets. It allows the User to
specify that the sheet number of the continuation sheet be shown at the
sheet break when the connection goes from one sheet of a drawing to
another. This option may now be set using the new checkbox option on

VANTAGE PDMS Version 11.6.SP5


User Bulletin

4-7

Piping Isometric Enhancements

the Annotation Options form (highlighted above as 2). Clicking this


checkbox will toggle between:
CONTSHEETS ON

Continuation sheet numbers between sheets are switched on.


CONTSHEETS OFF

Continuation sheet numbers between sheets are suppressed.

This is not to be confused with the CONTNOTES command which


specifies continuation notes at the end points on drawings when the
connection goes to another isometric.
4.10.1.3

Additional Attributes Shown at Sheet Breaks

An extra clause, ContUdefText (continuation user-defined text), has been


introduced to the CONTSHEETS command to specify that further
pipeline attribute or user-defined attribute (UDA) information may be
shown as part of the continuation sheet information displayed at sheet
breaks. The format of the constructed text string is controlled by the
User and may contain arbitrary text and carriage returns:
CONTSHEETS ON ContUdefText
'LATTR1''arbtext1''LATTR2''arbtext2'''

where LATTR1 and LATTR2 are valid Pipeline attributes and arbtext1
and arbtext2 are two arbitrary text strings. The sheet number of the
continuation sheet is automatically appended to the user-specified string.
Therefore, the example specified above would output the string
XXXXarbtext1YYYYarbtext2n for continuation sheet n where XXXX is
the value of LATTR1 and YYYY is the value of LATTR2.
This may be accomplished automatically by a new text box on the
Annotation Options window (highlighted above as 3). In the text box the
User is able to add something like:LATRR1/LATTR2-
where LATRR1 and LATTR2 are valid Pipeline attributes
This will generate XXXX/YYYY-n for sheet n where XXXX is the value of
LATTR1 and YYYY is the value of LATTR2.
A more concrete example of the use of the CONTNOTES, ContUdefText
option (combined with the COORDINATES option) is as follows. The
specified options:
Coords ON AT Sheet
ContSheets ON ContUdefText '''Name=''NAME''
Type=''TYPE''&/Lock=''LOCK'' Owner=''OWNER''
PSPE=''PSPE'' pg'''

VANTAGE PDMS Version 11.6.SP5


User Bulletin

4-8

Piping Isometric Enhancements

will display at the sheet break of an isometric:


E 12250
N 13500
EL +2735
Name =100-C-10 Type=PIPE
Lock= Owner=PIPES PSPE=A3B pg3
The COORDINATES option specifies the output of the first three lines.
Note that the user-defined text occupies the last two lines because a
carriage return &/ is specified. The value of the Lock attribute is not
output because, in this case, it is invalid. The continuation sheet page 3
specified indicates that this text would be expected to be located on sheet
2 of an isometric at the sheet break continuing onto sheet 3.

Note that a valid non-null string specified by the ContUdefText option


will always be output at sheet breaks, irrespective of whether the
CONTSHEETS option, specifying whether the continuation sheet
number is displayed or not, is set to ON or OFF.

4.11 Placing of Dimension Labels

*sp5*

A new DIMLABELS command is introduced, which allows the User to


control the appearance of dimension labels displayed on isometrics. This
option may be set to either of the two options:
DIMLABELS IN

Dimension labels are shown within the dimension line (the default).
DIMLABELS ABOVE

Dimension labels are shown above the dimension line.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

4-9

Piping Isometric Enhancements

This option may also be set by toggling between the two Dimension
Labels options (IN/ABOVE) on the Dimensioning Options form
(highlighted above). The effect of this option on the appearance of
dimension labels is indicated below:
ABOVE

IN

178

4.12 Improved Dimensioning Oriented Welds

*sp5*

A new option allows the user to control the dimensioning of components


on either side of a weld when the flow-through directions of these two
components are non-parallel. In earlier releases such configurations
could lead to inaccurate dimensions and skew/fall angles.
These non-parallel configurations may now be accommodated correctly
by using the WELDANGLES option. When this option is switched ON, it
is necessary for the user to also specify an angle as the minimum at
which the change of direction be considered significant. In other words,
for all angles greater than or equal to that specified, the new behaviour
for oriented welds occurs; otherwise, the old behaviour (equivalent to
WELDANGLES OFF), occurs.
This option may be set by using the new checkbox option on the
Dimensioning Options form. Checking or unchecking this box will toggle
between:
WELDANGLES ON

Oriented Welds option on.

WELDANGLES OFF

Oriented Welds option off.

When WELDANGLES ON is selected, the user may also specify the


minimum weld angle, WELDANGMIN, in the data entry box next to the
checkbox. The option WELDANGMIN takes the default value 0.10
degrees unless the user modifies it in the data entry box. Thus for the
case WELDANGLES ON, the Oriented Welds option is fully specified by,
for example,
WELDANGLES ON WELDANGMIN 0.08

The case WELDANGLES OFF is equivalent to the old behaviour and is


the default.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

4-10

Drawing Production Enhancements


For the PDMS Draft user, PDMS 11.6 provides access to a 3D colour
shaded graphical view for use in the definition of drawings. The user can
use it to define the contents of a drawing or to set the direction and limits
of a 2D view. This feature has been refined at PDMS 11.6.sp1.
For the PDMS Draft user, PDMS 11.6 provides access to a 3D colour
shaded graphical view for use in the definition of drawings. The user can
use it to define the contents of a drawing or to set the direction and limits
of a 2D view. This provides a highly intuitive and productive user
interface that will help to reduce drawing production times and enable
users to work in a familiar 3D environment. Users can create and
manipulate section planes in the 3D graphical view using direct
graphical interaction, and apply these section planes to any view on the
drawing. This displays in 3D the position of each part of the section plane
and is therefore simple to use, even for complex stepped section planes.
Further productivity improvement is achieved through the introduction
of a dockable database explorer and presentation of key annotation
features in a common application, removing the need for the user to
switch applications when adding basic annotation to drawings.
Isometric creation is typically performed as a batch job. However, for the
piping designer it is highly beneficial to produce a check isometric or
system isometric at various stages in the design process. PDMS 11.6 will
allow the piping designer to produce a standard isometric or system
isometric from within PDMS Design or PDMS Spooler, allowing the
designer to stay focussed on the piping design whilst generating
isometrics to assist in the design process. For further information, please
refer to the section on Design.

5.1

General GUI improvements


A new Office 2003 style GUI, based on Microsofts .NET, is now used in
Draft. This includes many new features such as window and toolbars
docking, tabbing etc. Please refer to section 2.2 Application framework
for further details.
In addition the Draft applications have been rationalised with the
various sub applications merged into a unified environment.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

5-1

Drawing Production Enhancements

5.1.1 Merged sub-applications


Dimensioning, Labels and 2D draughting applications have been merged
into one General application, so that all utilities are available to the user
without changing application or swapping menus.
DRAFT applications maintain the layer options (on the main window) to
enable the creation, in the appropriate place, of any 2D element,
dimension or label.
The Main Draft Menu has changed to remove the working sheet selection
and add a new members list explorer, with a mouse shortcut menu to add
a sheet to the 2D. The Dimensioning, Labelling and 2d draughting
applications have been removed, as they are now all merged into the
general application.
The Utilities from the 2D Draughting menu have been added to the
General Utilities menu, which is similar to the application utilities in
DESIGN.
Changes have been made to the Create and Modify menus as part of
merging the applications, with all the 2D draughting menus added to the
main menu.
5.1.1.1 Layers
The user can select a layer, but the application will select an appropriate
one, if required, before creating any element.
The layer gadget new has ALL the layers pertaining to the current sheet
listed, and this gadget can be filtered by using the new gadget Filter, to
list only those of the application the user is working on.
If the user changing from Dimensioning to Labelling, the application will
switch the layer gadget to list labels and select the first label type layer.
The user can re-select a different layer if required. The Layer gadget will
always change within the currently selected view, so if the user creates a
dimension in view 1 and then creates a label, the layer will switch to a
labelling layer in view 1.
Navigation around the DRAFT db automatically exchanges the layer
selection if a different view is selected. Clicking on a view has the same
effect as navigation to it.
Navigation to a dimension automatically changes the layer to a
dimension layer and highlights the view to which the dimension belongs.
This makes it easier to know where you are on the drawing and where
you are likely to create the next element.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

5-2

Drawing Production Enhancements

5.1.1.2 Database Hierarchy


Sheets may now be added to or removed from the 2D window from the
Explorer. This means it is necessary to check the position in the
hierarchy before adding something to the 2D window.
If the user is too high, i.e. above drawing level, then an error informs the
user that the REGI/DEPT is not a valid working sheet. However, if the
user is at drawing level, ALL the sheets are now added, even if there is
more than one. A message is displayed to inform the user that there are
several sheets, so they should check that they require them all to be
added.

5.1.2 User utility menu


A User application utility menu is now available in DRAFT, under the
general application. This utility allows the user to create menus for his
own use. The functionality is similar to that in DESIGN.

5.1.3 Dimension and 2D drawing forms


These forms have been changed so that dimensioning and 2D draughting
can be called from either form or toolbar. Some of the dimensioning
functionality has been moved from the utility menu and put under the
modify menu, to make it easier to find.

5.1.4 Labelling rationalisation


Labels have been rationalised and made dockable wherever possible.
This affects the Autotagging, Labelling and Gaps forms.
The autotagging form has been redesigned in order to reduce its size and
make it dockable. The regenerate tag button has been removed and
replaced with a toggle, so that the update button is the only button used
to execute the form. Checking the regenerate toggle and pressing update
regenerates the tags.
The labelling forms for SLAB (symbolic labels) and GLAB (General
Labels) have been combined and redesigned to be dockable, so that they
can be displayed all the time without obscuring the users view of the 2D
drawing canvas.
The main menu has been rationalised to show the new form, with the
modify menu reduced and some of the attribute settings removed, as they
are all covered in the new form.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

5-3

Drawing Production Enhancements

5.2

Use of the 3D features in DRAFT

(update) *sp1*

A 3D volume view is now available in DRAFT: it has similar properties to


that in Design. This can be used to explore the 3D model and identify
objects for drawing production.
There are also 2 database browsers: for Draft and Design databases. The
Design browser has a mouse shortcut menu option to add elements to the
3D view. You can also Drag-and-drop from the Design browser to the 3d
view.
Various improvements have been made to the usability of the 3D View at
sp1, notably to the behaviour of the view frame and section plane
features.

5.2.1 3D Commands
DESADD & DESREM commands allow the Addition and Removal of
Design elements to a 3D view gadget. These are similar to the ADD &
REM commands in Design. The GENERATE MODEL command allows
capture of a 2D view content and colour for addition to the 3D view.
The GENERATE MODEL command allows capture of a 2D view content
and colour for addition to the 3D view.
A new IDLIST object is now available to transfer the 3D contents to the
2D IDLIST (ADDE and REME elements).
A new SELECTION object provides a graphical aid of a 3D selection box.
This is called using the mouse secondary button in the 3D view.
A new VIEWFINDER object provides a graphical aid that represents the
2D view position, size and direction in the 3D view to allow interactive
positioning of the 2D view through point and view direction.

5.2.2 3D user interface


The new 3D view is similar to the 3D views in Design and may be
initiated from these menus: 3D View... from the shortcut menu for the 2D
view or Display > 3D View from the main menu.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

5-4

Drawing Production Enhancements

Associated
View

5.2.3 Managing 3D view content (Drawlist)


(ToolTip 'Add to View') adds elements to the 2D Idlist and the 3D
view. The Draft idlist ADDE elements are created at this time. This is
done to help workflow so the user does not have to do an UPDATE
DESIGN at this time. Updates could be done at anytime, even as a
background process or overnight job. The element added to the idlist will
generally be the current element, unless there is a multi selection active,
when the selection will be added. Elements added to the ID List will be
displayed in colour specified in the view representation rules.
(Tooltip Remove from View) removes elements from the 2D Idlist and
the 3D view. The Draft idlist REME elements are created at this time
The element removed from the idlist will generally be the current
element, unless there is a multi selection active, when the selection will
be removed.
(Tooltip Show View Content...' ) Show a form displaying the 2d view
Idlist (An UPDATE DESIGN may or not have been performed on this) .
This button is a toggle button to show or hide the ID List Contents form.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

5-5

Drawing Production Enhancements

This toggle gadget on the form, when ticked, means that the Idlist will be
amended appropriately when an element is added to (or removed from)
the 3D view directly from the Design Explorer. This is seen in the 3D
view in the correct representation colour.
If the gadget is unticked, this means that the element is added to the 3D
view only and the 2D Idlist is unchanged. Such items are added to the 3D
view in grey colour.
Therefore the significance of coloured items in the 3D view is that these
items have been added to the idlist. Grey items in the 3D view indicates
these items are in the 3D view but are not in the 2d idlist so even an
Update Design will not recognise these elements.

5.2.4 Multi Selection


The + and buttons will add or remove the current element unless a
Multi-selection has been made using the CTRL+pick or by dragging out a
frame.
A primary mouse button drag on the 3D view gadget will initiate a
selection box as shown below. This allows the user to multi pick elements
within or partially within a volume. The box can be resized by movement
arrows indicated on each side of the box. The box can also be used as a
clip box. Two separate examples are captured below.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

5-6

Drawing Production Enhancements

The following menu is presented when doing a secondary mouse button


drag:-

When the box is displayed it appears as above. The box can be resized by
dragging the arrows.
Picking the arrows on the displayed selection box with a mouse click the
following menu is shown.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

5-7

Drawing Production Enhancements

The background also has the following menu addition

Clipping Planes On This clips the graphics to the content of the


selection box.

5.2.5 Scale control


The view scale can be specified using direct input or form. Any change of
scale will be reflected in the 2D and 3D immediately.
The Scale gadget displays a standard scale dialog to maintain a
consistent feel in Draft.

5.2.6 UNDO/REDO
Database marks have been included:
1. When an element is added to the View The View Content form will
be updated.
2. When an element is removed from the View The View Content form
will be updated.

5.2.7 Modify Star


When the 3D View form initiates any database change such as:
Change in scale; Add to View; Remove from View; Move viewfinder,
(which modifies view through position)
the form title changes from 3D View to 3D View*
The * indicates that an Update Design is required using the
Once the Update Design is done the * indicator is removed.

button.

5.2.8 3D to 2D (Update Design)


(Tooltip 'Update 2D View from 3D view (i.e Update Design)')
The Elements displayed in the 3D view that are in the IDlist can be
transferred to a 2D view by simply pressing this button. At this time the
user may be asked if he wishes to do an Update Design and warned that
this can take a while. An Update can be done at this time or later by
using the Background Process Manager.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

5-8

Drawing Production Enhancements

5.2.9 2D to 3D
(Tooltip Update 3D View from 2D View)
The contents of the current 2D view can be displayed in the 3D view by
pressing this button. The associated view name is displayed next to this
gadget.
(Tooltip Pick 2D View to associate to the 3D View)
This button can be used to retain the current 3D view contents, to be
associate it to a different 2D view. The user is asked to identify a 2d
view. This is useful when different views of similar content are required
(e.g. Plan and Elevations)

5.2.10 Display of 2D view frame in the 3D view gadget

Figure 1

Figure 2

The limits of the associated 2D view are represented in the 3D view


using the VIEWFINDER. This is shown in the above snap shot by the
purple rectangle. The colour is, by default, the same as the highlight
colour of the 2d view but can be changed. The view finder is a core
object that can be:
1. Graphically dragged to reposition the view through point.
2. Graphically rotated using the corner blobs.
3. Graphically resized using the arrows shown in the Figure 2.
In each case the 2D database is changed. Note that a view can be
inverted or turned through 90 degrees by using the popup Rotate
Frame> options.
Similarly to switch between the Normal mode shown in Figure 1 and the
Resize mode shown in Figure 2 use the popup Resize Frame toggle.
VANTAGE PDMS Version 11.6.SP5
User Bulletin

5-9

Drawing Production Enhancements

5.2.11 Update control


It is PDMS User interface philosophy not to have hidden UPDATE
DESIGN operations. It is usually exposed so the user is aware that this
is going to happen, because this can take some time to update. Therefore
we have continued to separate this operation.
The Update Gadget has 3 options:

On Demand meaning UPDATE DESIGN when the 3D to 2D button is

pressed.

Background meaning UPDATE DESIGN as On Demand, by using the


Background Process Utility .
Auto Update meaning UPDATE DESIGN dynamically when the 2D

view changes (i.e. View Content, Scale, Direction, View Type, etc)

5.2.12 View Type

In the frame for update there is an option gadget to specify the type of
view to be generated in the 2D. The options in the gadget are the full
PDMS list of view types, ranging from Universal Hidden Line to
Wireline. Selecting one of these will change the database. Note that
section planes do not clip in wireline views.

5.2.13 Section Planes


(Tooltip 'Show Section Planes')
This toggle button activates the section planes and displays the Section
Planes form. Note that section planes can be individually hidden or
shown, so check settings on form..
(Tooltip Indicate Section Plane clipping')
This toggle indicates the clipping side of the section plane by graphically
displaying a series of perpendicular lines behind the section plane.

5.2.14 Representation in 3D view


It is possible to change the 3D representation, such as holes on/off, for 3D
elements as in Design.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

5-10

Drawing Production Enhancements

5.2.15 Viewfinder Shortcut menu.


Align Frame with 3D View Used to modify the view direction. Adjust

the 3d view to the desired view direction then use this option; and the
view finder will snap to this new direction.

Update Frame from 2D View If the view has been changed using 2D
appware the 3D could be out of date. Use this option to update the 3d
view.
Center Frame Centres the frame in the centre of the view gadget.
Rotate Frame > Options for Up, Down, Left, Right which allow the view
to be instantly inverted or turned through 90degrees.

Resize Frame (Toggle) Changes the mode of the View Finder so that is
can be resized. (See the above section Display of the 2D View in the 3D
View gadget )

Lock Frame This is a toggle that locks or unlocks the frame to prevent
accidental movement of the view frame. There is always an undo option
but the user may not be aware he has moved the frame.

Hide Frame Hides the frame by making it invisible. To reshow the


frame there is a Show Frame option on the view background menu.

Auto Update If this toggle is on then each time the frame is moved, an
Update Design is done. This should be used sensibly depending on view
content because large data will take a long time to process.

Frame Colour > White, Orange, Blue, Green, Magenta, Cyan, Yellow
Changes the frame colour to the selected colour toggle. The current
colour will be ticked.

Translucent Frame Gives the frame a background translucency or no


background. A translucent frame is easier to pick but can partially
obscure some of the content.

5.2.16 3D view Shortcut menu additions related to view finder.


Look >Through View Finder This is a quick way to change the 3d view
direction to look squarely through the view finder.

View Finder>Show Frame Reshows the view finder frame (The hide
option is on the view finder menu itself)
Highlight Frame Highlights the view finder frame by flashing it.
Similar to the Highlight CE in 2D view.

Center Frame Centres the frame in the centre of the view gadget.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

5-11

Drawing Production Enhancements

5.3

Template drawings
Create>New Drawing from Template utility.
Key Features:

5.4

The utility does not require the input of a name for the new drawing.

If the user is not at the correct hierarchal position, the system will
attempt to navigate to an appropriate place to create a drawing, and
ask the user to confirm if necessary.

Templates made from DRWG or DRTMPL are valid.

The Selection of the Template is more visual.

Once the drawing has been created, the user can then utilise the 3D
view to define the view contents. See below.

New Drawing creation and New Drawing Sheet creation are


allowed.

Default names or user names are allowed.

Section planes
The User can now create, edit and view section planes in a 3D model
window from within Draft, before adding these to a drawing view. This
makes it easier for the user to work with section planes, but does not
affect the existing working methods. It does improve the presentation of
section plane information and their effect on the drawing.
The Section Planes window is initiated from the 3D View window. It
enables the creation and editing of section planes, both simple and
stepped, and their associated clipping lists.

5.4.1 Improvements for *sp3*


Several improvements have been made to the operation of section planes,
including:

Planes are now shown on the 2D view at same time as on the 3D view.

There is now a new menu option (keyboard shortcut C) to cause an


extra step to close the stepped plane profile.

The axes and the drag plane can now be used to align the section
plane to a feature.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

5-12

Drawing Production Enhancements

5.5

The Modify Section form now updates the 3D view when Apply is
pressed. For example, if the plane is flipped, this is now shown in the
3D view.

Background processes
Certain PDMS commands may take a long time to complete. PDMS 11.6
introduces a background process manager (BPM) for managing the
UPDATE DESIGN command. This technology may be extended to other
processes in future releases of PDMS.
When the background process is updating a particular view, it is possible
for the user to edit another view on the same sheet. That is, there is no
contention between the foreground and background processes.
The BPM does NOT need to be active at the same time as the main
PDMS session. For example, the user can submit any number of
UPDATE DESIGN jobs and then exit before the BPM is started. The two
processes are completely independent so that the BPM can run
overnight, for example. However, once a BPM job has completed a
PDMS session must of course be started to refresh the updated element.
Picture files are not updated directly by the BPM.

5.6

AutoCAD integration with Final Designer


PDMS 11.6 will bring a new option for the final production of AutoCAD
drawings: first release is expected with the next service pack of PDMS
11.6. The new Final Designer product enables users to export their Draft
drawing sheets to AutoCAD with links to the Draft database maintained.
It is anticipated that users will continue to develop drawing sheets in
PDMS Draft and make use of the automation features: when a drawing
sheet is ready for final design it will be exported to AutoCAD.
An exported drawing sheet can be accessed through PDMS Draft by
navigating to the sheet and opening it. The sheet is displayed in an
AutoCAD session for viewing or further editing. Within AutoCAD, users
can add dimensions, labels, intelligent text and 2D primitives. Where
applicable, annotation can be attached to P-points or P-lines enabling the
annotation to be updated when the design graphics change.
If Design graphics change, they can be updated in the same way as
standard Draft views: the changes are shown on the AutoCAD sheet.
Creation, deletion and modification of annotation in AutoCAD are
communicated to PDMS Draft so that the database links are maintained,
however, full details of the definition are not communicated. This means

VANTAGE PDMS Version 11.6.SP5


User Bulletin

5-13

Drawing Production Enhancements

that, for annotation created or modified in AutoCAD, the AutoCAD sheet


stores the up-to-date definition.
Automation features in PDMS Draft should continue to work on
AutoCAD sheets with the exception of any commands that require
interaction with the Draft picture file such as ID commands.

5.7

UNDO/REDO

*sp1*

This is now available in DRAFT.

5.8

Pipe Sketch ADP

*sp4*

Automatic Drawing Production (ADP) has a new option to produce pipe


sketches automatically using production-checked pipe-spool data from
the Design application. The sketches include dimensioned scale drawings
of a pipe spool along with tables of relevant manufacturing data.
Pipe Sketch drawings are based on a Template Drawing, which contains
views and layers like any other Draft Template; for other Drawing
information the Template Drawing references a Backing Sheet. Users
will generally have their own Sketch Templates for Pipe Sketches.

5.8.1 Producing Pipe Sketches


To produce pipe sketches, you have first to navigate to a suitable level in
the design hierarchy and get a list of the spools for that level. Pipe
Sketches are produced using a form, which is invoked from the main
menu by choosing the Create> Pipe Sketches option.
The first time this is displayed, there will be a default AVEVA Template
in the Template field and a default log file name in the log file field.
When the form is applied the current settings of the Registry, Template
and Log File are written to a defaults file for use the next time the form
is displayed: this file is %pdmsuser%/PipeSketches.pmldat.

5.8.2 How to Use the Pipe Sketches Form


The form allows you to filter by name then select from the list of pipespools for which you want to create sketches. After you have identified
the template to use for the sketches and a place in the Draft database to
store the generated sketches you can generate the sketches.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

5-14

Drawing Production Enhancements

5.8.2.1

Design Element to Search Under


This is the name of the root design element,
which must be either a Zone or a Pipe.
You can populate the field using the CE
button or by typing in the name. The system
validates all typed input.
If you use the CE button, the text box
displays the name and the form initialises.

5.8.2.2

Filter the spools using


This lets you filter the pipe spools under the
root element according to various criteria.
When youve selected the criteria, click the
Search button to execute them.
All or part of the spool name includes spools
with names matching the text you enter,
either wholly or partially.
Production Status offers three options in a
drop-down list:
All: Matches all spools, both validated
and not validated.
Valid: Matches only spools valid for
production.
Not Valid: Matches only spools not
valid for production.
Sketch Status Filter offers three options in a
drop-down list:
All: Matches all spools, with and
without pipe sketches.
Created: Matches only spools with pipe sketches.
Not Created: Matches only spools without pipe sketches.

5.8.2.3 Search Results


This list is a collection of all the pipe spool elements of the of the root element, filtered
by the criteria above. The system processes only pipe spools selected in this list when
you click Create Sketches.
The results should be self-explanatory; however, the list also has a pop-up menu,

accessed by clicking the secondary mouse button anywhere in the list area:

The

VANTAGE PDMS Version 11.6.SP5


User Bulletin

effect of these Menu options is:

5-15

Drawing Production Enhancements

Select All: Selects all pipe spools in the list.


Clear Selection: Unselects all pipe spools in the list.
Print Sketch: Print the selected sketch.
Delete Sketch: Delete the selected sketch.

5.8.2.4 Display Button and Arrow Controls


Click on Display to add a sketch of the selected pipe spools to the working list of sheets
for display, although you can display only one sheet at a time. To navigate up and down
the list, use the up- and down-arrow icons.

5.8.2.5 Sketch Creation Options


These options are at the bottom of the form:
Sketch Template This must be an existing DRWG element that can be used as a
template for the pipe sketch drawings.
CE button This top CE button (denoted DRWG) allows for quick capture of the
current drawing.
Create Sketches in Registry The named element must be an existing REGIstry
element into which the system puts all new pipe sketch drawings.
CE button This bottom CE button (denoted REGI) allows for quick capture of
the current registry.
Log File The system records progress of the creation process as text that can be
written to file. This field shows the file name the system will write to. The system
overwrites this file if it already exists.
Browse button Invokes a standard browse form to let you select a log file.

5.8.2.6 Create Sketches


The Create Sketches button sets the process in action.
A message should appear in the status bar to record progress, e.g. Generate Pipe
Sketch n of N.
When the system has created the pipe sketches it adds them to the Draft Explorer.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

5-16

Drawing Production Enhancements

5.8.3 Pipe Sketch Administration


The system creates pipe sketches on templates and backing sheets you
can define yourself using the powerful facilities of the PipeSketch object.
5.8.3.1 Backing Sheet
The Pipe Sketch references the Backing Sheet, which is generally userdefined. It is a standard backing sheet containing the drawing title block,
with drawing data displayed via intelligent text,
e.g. #DATE<FR DRWG> and #:UDA_Name etc.
In addition to the standard title block, the backing sheet is used to
identify and locate TABLES that are used on the Pipe Sketch.
These tables are identified by:
MaterialTakeOff

function MTO

SpPurpose TABLE or SpPurpose CELLS

Bending Table

function BENDING

SpPurpose TABLE or SpPurpose CELLS

Bending Activities

function BENDINGA

SpPurpose TABLE or SpPurpose CELLS

Welding

function WELDING

SpPurpose TABLE or SpPurpose CELLS

Assembly

function ASSEMBLY

SpPurpose TABLE or SpPurpose CELLS

End Points

function ENDPOINT

SpPurpose TABLE or SpPurpose CELLS

5.8.3.2 Tables
In database terms the Table is a NOTE of the Backing Sheet (BACK).
There are two notes required, one for the Table headings and one for the
Table cells. Both notes are positioned at the same point. For example:
BACK named /DRA/MAS/BACKS/PipeSketch/A4 SETST
NOTE named */ExampleTable function ENDPOINT SpPurpose TABLE
NOTE named */ExampleCells function ENDPOINT SpPurpose CELLS

The example below is a table defined on a backing sheet. Although this


table is visible in the view, it will in practice have its visibility flag
(LVIS) set to false. The reason is that this table is copied onto the Pipe
Sketch Drawing then the cells of the table are populated with data from
the actual Pipe Spool.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

5-17

Drawing Production Enhancements

XYPOS of the
Tables (NOTE)

The figure below shows the table in situ on the final pipe Sketch Drawing.

5.8.3.3 MTO Tables


The figure shows the MTO/Material Take-off tables on the backing sheet. On this type
of table the cells data need to be attributes of the Pipe Spool elements, e.g. DTXR and
MTXR attributes as used in the Description and Material columns.

5.8.3.4 Other Tables


Bending, Bending Activities, Automatic Welding, Assembly Activities
and End Points tables are similar.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

5-18

Drawing Production Enhancements

5.8.4 Styles
All Drawing Styles and Representations are inherited from the template
drawing. These include the View Representations, text colours and font
size for Labels and Dimensions.

5.8.5 Common Object


The system uses one pipeSketches object that does all the work to
produce Pipe Sketch Drawings. This is so you do not have to use the form
and graphics mode to produce a batch of drawings.
The common object is a global instance of an object called !!pipeSketch.
5.8.5.1 Key Members:
Member

Type

Comment

!!pipeSketch.createIn

DBREF

Must be an existing Registry


REGI element

!!pipeSketch.selectedTemplate

DBREF

Must be an existing Drawing


DRWG element

!!pipeSketch.pipeSpool

DBREF

Must the an existing Pipe Spool


PSPOOL element

Member

Type

Comment

!!pipeSketch.logFile

FILE

The Form or User must write and


read this file

!!pipeSketch..drawingPrefix

STRING

Default is DR

!!pipeSketch..sheetPrefix

STRING

Default is S

5.8.5.2 Optional members

5.8.5.3 Other Members set and used in the background by the system:
Member

Type

Comment

!!pipeSketch..type

STRING

Will always be drawing or drtmpl

!!pipeSketch..pipePieces

ARRAY

System records the Pipe Pieces of


the Pipe Spool

!!pipeSketch..drawing

DBREF

System records the new drawing

!!pipeSketch..sheet

DBREF

System records the new sheet

!!pipeSketch..backingSheet

DBREF

System records the backing sheet


being used

VANTAGE PDMS Version 11.6.SP5


User Bulletin

5-19

Drawing Production Enhancements

!!pipeSketch..mtoHeadings

ARRAY

Array of strings read from backing


sheet MTO table

!!pipeSketch..logData

ARRAY

Array of comment strings that user


or form can read)

5.8.6 Log Messages


To write any message to the Log Data from any PML function use:
!!pipeSketchesLog(Text of your choice)

To clear the messages from the Log Data use:


!!pipeSketch.emptyLogData()

To write to the log file use:


!!pipeSketch.logFile = object FILE(%PDMSUSER%/pipeSketches.txt)
!!pipeSketch.openLogFile()
!!pipeSketch.writeLogFile() write the contents of .logData to the .logFile
!!pipeSketch.closeLogFile()

5.8.7 Table Definition Example


Under a Backing Sheet:
BACK /ExampleBack SETST

Create NOTEs
NEW NOTE */---Table SETST
FUNC --- (--- can be MTO, BENDING, BENDINGA, WELDING, ENDPOINT or ASSEMBLY)
SpPurpose TABLE

Set the XYpos and usual attributes for text size colour etc. Create and
name TEXP and STRA elements under the note. In the example below
there are 4 TEXP elements and 7 STRA elements (Shown in Black)
NEW NOTE */---Cells SETST
FUNC --- (--- can be MTO, BENDING, BENDINGA, WELDING, ENDPOINT or ASSEMBLY)
SpPurpose TABLE

Set the XYpos and usual attributes for text size colour etc. Create and
name TEXP and STRA elements under the note. In the example there
are 3 TEXP and 1 STRA elements (Shown in red):

VANTAGE PDMS Version 11.6.SP5


User Bulletin

5-20

Drawing Production Enhancements

NB. The */ColumnLine1 direction of From Point and To Point defines the direction of the rows.

5.8.8 Dimensions
Dimensioning is controlled from the Template Drawing:
A VIEW will be dimensioned only if it has a LAYER with a PURPose of
DIMA. If this layer exists, the dimensions go into that layer. The style of
the dimension will be cascaded from the owning layer.

5.8.9 Tags
Tagging is controlled from the Template Drawing:
A VIEW will be tagged only if it has a LAYER with a PURPose of LABA.
If this layer exists, the tags will go into that layer. The style of the tag
will be cascaded from the owning layer, or taken from a symbol template
in the case of component tags.
A typical symbol may look like this:

VANTAGE PDMS Version 11.6.SP5


User Bulletin

5-21

Drawing Production Enhancements

To control how the components of the Pipe Spool are tagged.

Firstly:
A LAYER with PURPose of LABA must own a TASK element with a
SpPurpose of TAGDEF which owns 4 Task Parameter elements
(TKPARA) with FUNCtion equal to TEMPLATE, OFFSET, TPEN and
FPEN and suitable TPVALUEs.
For example:
LAYER
TASK
TKPARA
FUNC TEMPLATE TKPARA /MySymbol
TKPARA
FUNC OFFSET TKPARA 10 10
TKPARA
FUNC TPEN TKPARA 1
TKPARA
FUNC FPEN TKPARA 11

When tagging views, the system will create a Symbolic Label (SLAB) for
each component, using the attributes of the above task parameters.

Secondly:
A LAYER with PURPose of LABA must own a TASK element with a
SpPurpose of 'ARRLAB' which owns 6 Task Parameter elements
(TKPARA) and specific FUNCtions and suitable TPVALUEs.
For example
LAYER
TASK
TKPARA
FUNC Top Side TKPARA On
TKPARA
FUNC Bottom Side TKPARA Off
TKPARA
FUNC Left Side TKPARA On
TKPARA
FUNC Right Side TKPARA On
TKPARA
FUNC Margin TKPARA 5
TKPARA
FUNC Minimum Gap TKPARA 1

When tagging views the system will arrange the Label around the view,
using the attributes of the above task parameters.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

5-22

Parameterised Property Attributes

6.1

Introduction

*sp4*

Weight and Centre of Gravity calculations use CWEI & UWEI attributes
in the Property Database. Until PDMS 11.6.SP4, these attributes were of
type literal; they have now been extended to allow the use of Design
Parameters. This should be especially useful for highly parameterised
catalogues, such as those used typically for HVAC & Pipe Supports.

6.2

Property attributes affected

*sp4*

The following Property attributes can now be parameterised:


For CMPD & TUBD elements:
CWEI, CIWE, UWEI, UIWE, ACBO, BTOL, WTOL, WDIA, SHAP,
PRFC, CORA, EFAC, PWAS, BFLE & OUTD
These can be set with standard expression syntax such as:
Cweight ( ATTRIB PARA[2 ] + ATTRIB PARA[3 ] )
Outdiameter ( ATTRIB PARA[1 ] + ATTRIB DESP[1 ] )

Existing syntax is still valid, for example:


UWEI 2.5

The following pseudo attributes have been updated to use the


parameterised properties:
BRWEIG

BRANCH WEIGHT

BRIWEI

BRANCH INSULATED WEIGHT

BRWWEI

BRANCH WET WEIGHT

BRWIWE

BRANCH WET INSULATED WEIGHT

BRIARE

BRANCH INTERNAL SURFACE AREA

BREARE

BRANCH EXTERNAL SURFACE AREA

WALLTH

TUBE WALL THICKNESS

A new pseudo attribute, PROPRE, has been added to allow the querying
of the calculated result of the property attribute. This is a valid at the
VANTAGE PDMS Version 11.6.SP5
User Bulletin

6-1

Parameterised Property Attributes

design element which indirectly references the property component such


as a branch or hanger member. It has a qualifier of the property attribute
to be evaluated and can be queried using the syntax:
Q PROPRE OUTD

6.3

Upgrade Requirement

*sp4*

Warning: Users DARS and PML applications will need upgrading if


parameterised properties are used.
Prior to SP4, a DARs program had to navigate to the relevant CMPD or
TUBD element and then query the real attribute, in order to obtain a
property for a piping component or similar. DARS has been updated so
that this still works for either existing data or for simple expressions;
however, it will give the wrong answer if more complex expressions are
used.

The type of expression that will not work is one which uses PARA or
DESP while a simple expression is similar to (33.5 * 8.6)
To upgrade any such DARs applications, use the pseudo attribute
PROPRE of the Design element, with the qualifier of the property
required.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

6-2

Admin enhancements for Global

7.1

Querying Remote databases

*sp4*

The Remote File Details and Remote Last Session form can be invoked in
two ways:
Either

Or

From Admin Main Query menu bar:

Popup menu in Admin Element form:

Query>Project>Remote Filedetails
Remote Last Session

Query>Remote Filedetails
Remote Last Session

Figure 1

Figure 2

Selecting the Remote Filedetails option displays the form below.


The main function of this form is to get the file details of one or more
databases for the current or any other location.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

7-1

Admin enhancements for Global

Selecting the Remote Last Session option displays a similar form with
results relevant to the last session:

In both forms, the Location option lists all the online (not offline)
locations. On selecting a location, all the databases of that location will
be listed. If the Daemon of the selected location is not working, the Apply
button is de-activated and the status of daemon will appear adjacent to
the button. While the system establishes connection with the Daemon of
the selected location, the status file informs the user. Select one or more
databases from the list and press the Apply button. Now the resulting
file detail or session detail of the selected database(s) is listed on the
right of the form, along with the database name see below.
VANTAGE PDMS Version 11.6.SP5
User Bulletin

7-2

Admin enhancements for Global

Results can be stored by entering a file name and pressing the Report
button.

Sort by and Filter gadgets work in a similar manner to those in the


admin forms.
If the daemon is not in contact for the selected location, the Apply
button is de-activated and an error shown adjacent to it, as shown below.
The Test Communication button is an additional utility to check the
Communication status of the daemon, so that the user can check it before
selecting the Location. This shows the Test Project Communication form.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

7-3

Admin enhancements for Global

7.2

Purge Transaction commands

*sp4*

A facility for purging transactions is now available from the Command


Transactions Form.

This will display the Command transactions form:

Selecting the Purge/Merge transactions DB tab will show:

The Left hand side only of the Form gets changed.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

7-4

Admin enhancements for Global

Transactions may be purged based on the result and/or age of the


transaction.
The option Older than is provided to enter the age of transactions that
will be included for purging: this should be in the range of 1 to 365 days.
The Purge Transactions DB button will action the Purge, once the
appropriate details have been selected.
The options ALL / SUCCESS / FAILURE are available for the Purge
option. Selecting ALL will delete all transactions which are not in
progress and older than the specified age. Selecting SUCCESS or
FAILURE will purges only Passed or Failed commands as appropriate.
Redundant owning elements will also be deleted.

Merge Transaction DB will merge the transaction DB of the current

location. This will have no effect unless the database has been purged or
commands have been deleted interactively.
The Command transactions form is available in other modules, but does
not have the Purge transactions frame.

7.3

User Interface enhancements

*sp5*

For full details, please refer to the AVEVA Global 2.5 User Bulletin.

7.3.1 Admin elements Form

On the Database drop-down: Display the Primary Location

Sort on Location

Filter Primary and Secondary Databases

View Data for read-only Satellites

7.3.2 DB Allocation (By Location/By Database) Forms

Filter on Primary/Secondary locations

7.3.3 Create DB Form

Display underlying database type

Widen Description Textbox

VANTAGE PDMS Version 11.6.SP5


User Bulletin

7-5

Admin enhancements for Global

7.3.4 Create Location Form

Display available Parents/Groups/Administrating Locations


on the same form

7.3.5 Extract Control Form

PING button to check Global Communications

Feedback on action button to indicate a command has been


received

7.3.6 Main Tool bar

Lock/Isolate radio gadget removed from the Main Tool Bar


now available under Remote Menu Status of Lock/Isolate is
still indicated on the Tool Bar

7.3.7 DICE Form

Filter on Primary/Secondary Locations

Display more Databases

7.3.8 Transaction Command Timings Form

Default Settings should be more efficient

7.3.9 Create MDB Form

Display Primary Location of the Database

Feedback when Data has been modified

Enhance the Filter on the DB List

View more Databases within the lists

VANTAGE PDMS Version 11.6.SP5


User Bulletin

7-6

Customisation

8.1

Application switching
The application switching mechanism in Design, Draft and Paragon has
been changed to remove the need to swap the main form when changing
application and to make it easier for the user to make additions to the
appware. An object provides more control over the display of forms in
different applications.
PML add-ins are available in PDMS 11.6.
An add-in can:

appear as an application on the main PDMS menu bar;

define menus and toolbars;

add menu fields and toolbars to applications;

remove menu fields from applications;

cause functions to be run when starting or switching between


applications.

Each existing application is implemented as a PML add-in. It is


important to make a distinction between an add-in that defines an
application and other add-ins. An application appears on the
Applications menu and can be switched to, whereas an add-in simply
provides a means of adding functionality to the module.
Information on how a user may upgrade existing applications and define
PML add-ins and control form display/reloading can be found in the
PDMS Software Customisation Guide Chapter 24 PML Add-ins.

8.2

Forms & Menus (PML) Enhancements


An improved Gadget Set for PDMS 11.6 provides:

Docking forms in the PDMS Application Framework


Definition of intelligent resizable forms
Toolbar definition in the PDMS Application Framework
Tabbed multi-page form definition
User-defined menu field names
Menu and menu bar editing enhancements

VANTAGE PDMS Version 11.6.SP5


User Bulletin

8-1

Customisation

Other miscellaneous enhancements.


1. DIALOG forms are floating by default, but may be declared docking.
Docking dialogs are necessarily resizable and can be docked to an edge
of the PDMS Application Framework. Docked dialogs can be specified
as docked, or can appear floating and then be docked interactively.
2. DOCUMENT forms are MDI children by default, and as such will be
constrained within the PDMS Application Framework MDI client
frame. However they may be interactively floated outside the MDI so
that they can be dragged off onto the second screen of a twin screen
installation. Similarly a floating dialog can be interactively unfloated,
i.e. once again constrained within the MDI frame.
3. The layout of resizable forms has been improved by exposing
WinForms properties Dock and Anchor on most F&M gadgets. In
particular, a frame gadget itself has Dock and Anchor properties, and
may own other frame gadgets. The gadget Dock and Anchor attributes
permit the definition of intelligent position and resize behaviour when
its container gadget resizes. The net effect is to allow multiple
resizable gadgets on a form and predictable and potentially complex
resize behaviour. Existing resize behaviour has been maintained.
4. The Frame gadget is now a genuine container for all gadgets defined
within its scope. This permits easy management of properties such as
visibility for all its children. It also supports various frame types,
which allow the definition of toolbars in Main forms and Tabbed Pages
within Dialogs and Documents.
5. Menu field names and Menu and Menu bar enhancements are
supported as a basis for menu editing for sub-applications and Add-ins.

to support PML defined main menus for Add-ins


to support PDMS core-code to take over main menus

to support enhanced menu editing

to support enhanced Bar-menu editing

5. Miscellaneous enhancements
Every gadget has a VISIBLE property, which can be queried and
set via PML.
Graphical view gadgets now have BACKGROUND and
HIGHLIGHT methods to query the view background and
highlight colours as colour-name strings.
Previously only pix-mapped buttons supported toggle behaviour,
i.e. on/off state with visual differentiation: this has been
extended to allow toggle button behaviour for all buttons.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

8-2

Customisation

8.3

Further PML (Forms & Menus) changes

*sp1*

Further improvements to PML forms & menus capability for this service
pack are noted here: full details are given in the two PDMS Software
Customisation Manuals, which have been updated and expanded.

8.3.1 Gadget layout management


It is difficult to predict the extent of gadgets which have a displayed Tag
attribute, because the size depends on the particular tag string. This is
made worse for gadgets whose content is also defined by a string (or
strings) rather than by an explicit width and height specification, e.g.
TEXT, OPTION, RGROUP. Determining the width as the number of
characters in a string multiplied by the grid size (notional character size
for the font) is not satisfactory because typically a mostly lower case
string of 10 characters say, only occupies about 60-70% of the 10 X
notional character spaces. Thus it usually results in lots of blank space,
but for pictorial fonts, such as Korean and Japanese, where the
characters tend to be wide it may cause truncation or wrap-round of the
displayed string.
8.3.1.1 Tagwidth and ButtonWidth attributes
The introduction of an optional Tag width specification for TEXT,
OPTION, RGROUP and TOGGLE gadgets and ButtonWidth attribute for
RGROUP gives the user (and F&M) more control over the size of gadgets,
independent of any string content and is upwards compatible. This
allows the Appware writer the possibility of removing the unwanted
empty space in gadget tags and radio groups and greatly improves
alignment possibilities with other gadgets.
8.3.1.2 Relative Gadget Extent specification
Form layout syntax has been extended to allow gadget size specification
relative to the size of previously defined gadgets on the form. This
mechanism makes it easier to construct forms in which the widths and/or
heights of various gadgets need to be the same as one another.
The combination of tag width specification and gadget relative size
specification greatly improves the ability to produce predictable form
layouts. This is particularly important for the construction of intelligent
resizable forms, where the static layout must be correct, but may never
actually be seen because of resizing during the first display.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

8-3

Customisation

8.3.1.3 Button Width and Height specification


New Button Width and Height specification allows the Appware writer to
remove the unwanted empty space in Buttons and greatly improves
alignment possibilities with other gadgets.
8.3.1.4 New No gadget auto-alignment property for Forms
Traditionally PML Forms have the notion of a set of linear gadgets,
namely BUTTON, TOGGLE, TEXT, OPTION, single line PARGRAPH
and horizontal RGROUP with no tag. These are gadgets which fit within
1 vertical grid unit, and which are pseudo-centre-aligned with each other
when displayed. This pseudo-alignment gives sensible layout for simple
forms for PATH RIGHT (the default) and PATH LEFT, but introduces
small errors in all other circumstances.
A new form setup keyword noalign has been introduced, which prevents
this (historical) gadget auto-alignment from happening. If proper centrealignment of gadgets is required for horizontal layout paths then the
VALIGN CENTRE command should be used, which applies accurately to
all gadget types.
This NoAlign setting is recommended when designing new PML forms.

8.3.2 Form enhancements


8.3.2.1 New QUIT callback
Forms now have a QUIT callback which allows intelligent support of the
Quit/Close icon on the title bar of forms and the main application
window.

8.3.3 New SLIDER gadget


This allows the interactive generation of an integer value in a specified
range (see the border controls on 3D views). Vertical and horizontal
sliders are supported.

8.3.4 New radio group facility


It has become apparent that quite a lot of Appware overlays the radio
group gadgets (RGROUP and the deprecated RADIO) with other gadgets
e.g. toggles, texts, buttons, options to allow qualification of the selected
option. The Customisation User Guide and Reference Manual warn
repeatedly that overlaying gadgets is bad practice and unpredictable, but
it is not possible to include other gadgets within an existing radio group
gadget. We have extended the Frame gadget to have a radio group
VANTAGE PDMS Version 11.6.SP5
User Bulletin

8-4

Customisation

property, and introduced a new radio button gadget, the Rtoggle, which
can only be added to Frames. The totality of radio buttons defined within
the Frame will act as a radio group. Any other gadgets can be added to
the Frame in the normal way.

8.3.5 List gadget enhancements


8.3.5.1 Multi-selection list new Start_Batch and Stop_Batch events
Multi-selection lists may now generate a batch of events. The metaevents START and STOP are now raised to bracket the set of
UNSELECT and the set of SELECT meta-events. Any programmatic
modification to the lists content or selections should only be made at the
STOP batch event.
8.3.5.2 New ADD methods for List and Selector gadgets
The methods ADD have been added to allow a single new entry to be
appended to the current set.

8.3.6 Option gadget enhancements


8.3.6.1 Scrolling of text within display field Option gadgets
The current value for a textual option gadget, shown within the display
field, can now be scrolled so that all of it can be seen. This enables users
to specify a gadget display width smaller than the drop-down list string
lengths.
8.3.6.2 New ADD methods for the Option gadget
The methods ADD have been added to allow a single new entry to be
appended to the Option gadgets drop-down list.

8.3.7 Miscellaneous
8.3.7.1 New FMSYS method to load/get a Form by name
Allows force loading of form definition and/or the ability to get a form
object from its name.
8.3.7.2 New Modified event for Text gadgets
The Text gadget now supports a MODIFIED event (action string).

VANTAGE PDMS Version 11.6.SP5


User Bulletin

8-5

Customisation

8.3.7.3 Control of RGROUP radio-button active status


The methods setActive have been added to allow control of the active
(greyed-in) status of individual radio buttons of the RGROUP gadget.
8.3.7.4 Query background colour name using the .Background() method.
Most gadgets now support this method.
8.3.7.5 SHOWN event for tabbed forms
For frames which are tabbed pages within a Tabset frame, F&M now
generates a SHOWN event whenever the user interactively selects a
new tab. The event is only fired for tabbed page frames which have a
PMLOpen callback defined. This is so that we dont upset the current use
of the frame as Rgroup SELECT event, which can be applicable to tabbed
pages but can be handled via a simple (non-Open) callback.
If you want to manage tabbed pages which also contain RToggles, then
you must supply an open callback so that you can differentiate the
SELECT (rtoggle) event and the (page) SHOWN event.

8.4

Internationalisation
Several improvements have been carried out to improve the availability
of local language support in PDMS. Further work is planned for future
releases, when the whole handling of local languages is due to be
updated in line with Windows standards including Unicode UTF8
character handling throughout.
At this stage, the languages supported are as PDMS 11.5: details are
given in the Installation guide. However, the new .NET GUI does work
in a slightly different manner, so some of the recommendations are now
more important.
Use of local languages is supported for use in PDMS names and text, but
not for PDMS word attributes this affects things such as SKEY, PKEY,
COCO etc. or for username or password. They are not recommended
for use in filenames: if used, macros are more likely to work if run using
this syntax:
$M <filename>
rather than:

8.5

$M /<filename>

Localisation
Many of the PDMS user interface gadgets are now defined using
Microsofts .NET, so they may be handled by some of the new tools.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

8-6

Customisation

Localisation deals with customizing data and resources for a specific


culture or locale language. All .NET Add-ins (Explorer, Explorer
Settings, Reference List, DrawList, and My Data) are localizable in that
all text and context menu strings are defined in a binary resource file.
This file is called PDMSResources.resources and lives alongside
PDMSResources.dll i.e. the %PDMSEXE% directory. It is created from
the xml file PDMSResources.resx using the .Net utility RESGEN.
PDMSResources.resources is the default resource name. This is the
resource file that the .NET runtime will look for when running PDMS - if
there are no language-specific resource files available. If there is a
resource file that matches the current culture then PDMS will use this.
In order to customise the Add-ins the user can either modify the default
resource or create a resource file for the intended culture. For example,
to create a resource file for UK English culture (culture Name: en-GB)
copy the default resource file PDMSResources.resx to
PDMSResources.en-GB.resx and modify the copied file.

8.6

PML Encryption

*sp4*

PML encryption is a new option available to use with PDMS 11.6.sp4 and
future releases of PDMS. It is intended to allow PML developers to issue
their applications for general use without disclosing the source code and
hence the details of the techniques used.

8.6.1 Decryption
PDMS 11.6.sp4 onwards can run PML files that are encrypted using
AVEVAs pmlencrypt utility. The resulting PML files can no longer be
read or edited but no special action is required to run them in PDMS.

8.6.2 Encryption
The pmlencrypt utility is a separate program that encrypts PML files. It
is up to the user to decide which file(s) he wishes to protect in this way,
though it should be used only on PML functions, objects forms and
macros and not, for example, images that might be stored in the same
directory. It requires a PML Publisher licence in the license file (the
feature name is VPD-PMLPUBLISHER). Please refer to the user guide
for full details.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

8-7

Customisation

8.6.3 Buffering
Decrypting a PML file takes longer than reading a plain-text version, and
in some circumstances PML files may be re-read many times during a
session. (A new command PML STATISTICS displays information on the
numbers of times each file has been read and some extra information
useful to AVEVA when testing the Published PML facilities).
In order to reduce the time taken to re-read the files Published PML files
may contain a buffering directive in the header-line (the first line in the
file). If a dash and a number are included directly after the three-digit
encryption algorithm id, then PDMS will retain the file in memory
indefinitely once it has been read that many times.
You may wish to edit heavily used files to add buffering to the header by
hand, or may use the buffer 5 option of pmlencrypt.exe to include a
buffer after five reads tag in each file encrypted.
A value of five is a good number to start with. Many files are read
precisely once during module start up: there is little benefit in buffering
those files, and a value of five will avoid that, but apply to all heavily
used files.
If a file you are actively developing has a header including buffering, it
will not be re-read as often as you are used to. To force all buffered files
to be cleared from memory if they are not in current use you can issue
the PML REHASH or PML INDEX commands, or switch modules.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

8-8

Incompatible PML changes

9.1

Summary
Great effort has been made to maintain upwards compatibility between
the current and previous versions, while introducing major changes. The
following are known potentially non-upwards compatible changes.

9.2

Functional changes at 11.6


The button gadget method !button.val returns type Boolean rather than
type String. Note this is in line with the documented behaviour, but is a
change from the previous actual behaviour.
A menu can no longer be referenced from several different places in the
Main menu system, i.e. the menu bar hierarchy of a form. If users have
made use of this, they will need to duplicate the shared menus. This
should be restricted to the form definition and is essentially a cut and
paste job. An attempt to reference a menu more than once will cause an
error alert to be raised.
The restriction on the Shortcut menu system is that a given menu can be
called from different shortcut trees, but cannot be used more than once in
a single shortcut tree. Infringing this will cause an error alert to be
raised.
A menu cannot now be used both as a Shortcut menu and as a Main
menu. If users have made use of this, they will need to duplicate the
shared menus. Infringing this will cause an error alert to be raised.
Remember the recommendation to set the menu usage mode of all
shortcut menus to POPUP.
We have removed the unpublished menu and menu bar Marker field
facility. The Marker is an invisible field which acts as a reference point
for the Clear methods of Bar and Menu. If this facility has been used
then it should be replaced by use of the named menu fields and the Menu
and Bar editing enhancements.
The ability to assign a user defined Shortcut menu to the TEXT gadget
has been withdrawn, because it clashes with the default Edit shortcut
which allows standard cut, copy and paste actions on the text field.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

9-1

Incompatible PML changes

9.3

Layout changes at 11.6


The spacing between radio buttons within the RGROUP gadget must
now be set explicitly rather than being derived from the VDIST and
HDIST setting in operation at the point of definition.
We have switched to using variably spaced fonts to improve the overall
appearance of the user interface. This has produced various layout
changes, because the form co-ordinate grid size is determined by the
nominal character size for the font. The actual size of a given character
is rarely equal to this nominal size. Most lower case characters are
smaller than the nominal size (a, e, i, o, u, j, l, p etc.) whilst a few lower
case characters, numerics and upper case characters are often bigger
than the nominal size (m, W, M, K, 2, 3 etc.). In particular the space
character may well be relatively small. These relationships also differ for
different font families. Thus, for a string of, say, 10 characters, the actual
display length is generally shorter than 10 grid spaces, but may be longer
if most of the character are Big (i.e. larger than the font nominal size).
This has a number of repercussions:
1. The 'Width' specification for a gadget is the number of grid units
assigned to the gadget, not the number of characters that it can hold.
Often the gadget will be able to accommodate more characters than
width, but if the characters are all Big then it will accommodate
fewer than width. Some adjustment may be needed to existing
Appware to reflect this change.
2. A similar situation exists for gadget Tag text. The space assigned for
the tag text is determined as (number of tag characters multiplied by
the grid unit size), not by the actual size of the tag string. This
supports the use of padding tags with trailing spaces to achieve left
alignment of a column of gadgets, i.e. all the gadgets to be aligned
should be given tags with the same number of characters in their tag
texts. For existing Appware, there may be a few cases where gadget
tags have a high proportion of Big characters, and additional trailing
spaces will need to be added to prevent tht displayed tag being
truncated or wrapping round.
3. A similar situation exists for paragraph gadgets whose width is set by
the Text keyword, e.g. para .p1 Text|WAM|. In this example it is
probable that an extra trailing space will need to be added to the
string to prevent truncation.
4. The form title no longer contributes to the extent of the form, so forms
with long titles may now be shorter.
5. The menu bar size calculation is factored down because menu fields
tend to have few upper case and numeric characters. The menu bar
contributes to the form extent, so forms with long menu bars may now
be shorter. For dialog forms with a menu bar only and no gadgets, it
is recommended to declare the form Resizable if possible, or to pre-

VANTAGE PDMS Version 11.6.SP5


User Bulletin

9-2

Incompatible PML changes

specify its minimum size to ensure that all the menu bar fields
actually appear.

9.4

Functional changes

*sp1*

9.4.1 Multi-selection list Extra Start and Stop meta-events.


At PDMS11.6 we introduced support for Extended Selection Mode for
multi-selection lists, whereby CTRL and SHFT keys can qualify the list
selection. As a result a whole set of UNSELECT events followed by a
whole set of SELECT events can result from a single (atomic) user action.
These events are presented in sequence, but Appware cannot tell where
the sequence starts or ends.
At PDMS11.6, problems may arise if a multi-selection list is
programmatically changed during the list callback. Modifying the list
content or its selection during the sequence can cause unexpected results
or even software crashes.
At PDMS11.6Sp1 we nave introduced new START and STOP batch
actions to bracket the sequence of UNSELECT and SELECT event
actions.
For maximum upwards compatibility, the START and STOP batch
actions are only notified to PML if the user has assigned an open
callback, since this is the only way that different event types (actions)
can be differentiated. Please see the PDMS Software Customisation
manuals for more information.
Appware which used simple callbacks and worked at PDMS11.6 will
continue to work because START and STOP events will not be notified to
it.
Appware which used open callbacks and worked at PDMS11.6 will
continue to work if the SELECT and UNSELECT meta-events were
explicitly differentiated in the callback, as shown below, because the new
START and STOP events will be ignored.
Define method .listSelectionChanged( !list is GADGET, !action is STRING )
...
if( !action eq SELECT ) then
...
elseif( !action eq UNSELECT then
...
endif
...
endmethod

VANTAGE PDMS Version 11.6.SP5


User Bulletin

9-3

Incompatible PML changes

If you experience a change in behaviour, then you may need to rewrite


your callback to explicitly handle the new START and STOP events and
modify the list content or its selection only on receiving the STOP event
action.
For newly written Appware we strongly advise the use of open callbacks
to service multi-selection list gadgets!

9.5

Layout changes

*sp1*

The following changes may well not be apparent for most forms which
have been defined by relative gadget placement (as recommended)
The start position for an OPTION gadget has moved left by 1 grid unit.
The width of an OPTION gadget with unspecified width and content has
decreased.
The extent of a TEXT gadget with no tag has decreased by 1 grid unit.
The extent of an RGROUP gadget set by a long title (rather than by the
size of its included buttons) has decreased.

9.6

Parameterised Property attributes

*sp4*

Applications may need adjustment if this new option (at SP4) is used
see also note on upgrades to DARs programs.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

9-4

10

Updates to standard projects

10.1 Supports catalogue for MDS

*sp4*

The MAS project now includes a dictionary database for MDS


(MASTER/MDSDICT). Please note that MDS uses a lot of user-defined
attributes (UDAs); if you use the AVEVA projects but not MDS, you may
wish to defer this database to reduce the chance of reaching the limit.
The limit for UDAs will be increased for PDMS 12.
At this release, the dictionary database is still also supplied as part of
MDS, as before.

10.2 Australian Steel Catalogue

*sp4*

A new structural steel catalogue and specification for profiles conforming


to Australian and New Zealand Standards has been added to the
MASTER/STLCATA database at PDMS 11.6.sp4.
The catalogue includes profiles detailed in the relevant standards as well
as Tees cut from Universal Beams and Universal Columns derived from
data published by the Australian Institute of Steel Construction. Equal
Angles from New Zealand production have also been included.
The information sources used for the catalogue are:
AS/NZS 3679.1:1996 Hot-rolled bars and sections.
AS/NZS 3679.1:1996 Welded I sections
AS 1163:1991 Structural steel hollow sections.
Extracts from the Design Capacity Tables published by the Australian Institute
of Steel Construction (Australian Steel Institute).

The catalogue hierarchy follows that of the AISC (American) catalogue,


i.e. the Reference Data is self-contained within a reference STCA in the
appropriate shape STSE.
The profiles use the standard AVEVA Generic Types (GTYPE), as
detailed in the Structural Design Using VANTAGE PDMS manual
supplied with the product. Parameter naming, data set DKEY and
DTITLE attributes are based on the AISC (American) catalogue.
SPRF element names have been taken from the relevant standards
(without spaces). The Description attribute of the SPRF has been set to

VANTAGE PDMS Version 11.6.SP5


User Bulletin

10-1

Updates to standard projects

the name of the SPRF with appropriate spaces inserted. The Description
attribute may be used in Draft to label a SCTN or GENSEC by setting
the label intelligent text to #DESC<FROM CATREF>.
The relevant Australian and New Zealand Standards do not specify
bolting cross-centre and backmark dimensions. The values given are
based on existing PDMS catalogue values for similar shape sizes from
other Standards.
Level and Obstruction attributes have been set for all shape geometry
elements in accordance with the following table:
Drawing
Levels

Representation

Obstruction
Value

Simple Draft

0-3

Detailed

4-8

Obstruction

9 - 10

Note:
Simple Draft representations have no root or toe radii included, where
applicable. Obstruction volumes have been constructed such that they do
not cover the detailed profile shape.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

10-2

11

Product Faults and User Requests

11.1

Known faults and Outstanding Issues

11.1.1 Windows fault correction available


ToolTips may not work properly, on computers with accelerated OpenGL
video adapter drivers, after starting PDMS 11.6. This is due to a fault in
Windows XP which is corrected in Service Pack 2: see
http://support.microsoft.com/?id=814135 and
http://support.microsoft.com/default.aspx?kbid=811113.

11.1.2 Windows faults file locking


There are faults in some versions of Windows related to file locking,
which is used for PDMS databases. These typically manifest themselves
as MCD errors or a PDMS session hanging. Hotfixes are available from
Microsoft for some versions of Windows and they are corrected in the
latest service pack of Windows XP.
Full details and the latest advice are given on the PDMS support pages
on the Internet.

11.1.3 Microsoft .NET Framework Hotfixes KB886903 & KB886904


Microsoft Windows Operating System Hotfixes (patches) KB886903 &
KB886904 for the .NET Framework can cause problems with PDMS.
These are security updates, so Microsoft recommends installation at the
earliest opportunity. For more details, please see:
http://support.microsoft.com/default.aspx?scid=kb;en-us;895242.
The version of the .NET Framework supplied with PDMS, which was
used by AVEVA for testing, is 1.1 for which the hotfix is KB886904.
However, users have reported problems with PDMS when this hotfix is
applied. PDMS Design and other modules fail to initialise and give a
series of errors, starting with:
System.InvalidOperationException: Unable to generate a temporary
class (result=1).

The simple solution is to uninstall the patch and reboot, after which
PDMS should start normally.
An alternative solution, which removes the vulnerability, is to upgrade to

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-1

Product Faults and User Requests

.NET Framework 1.1 Service Pack 1 (SP1) and then apply the correct
hotfix: KB886903.

11.1.4 PDMS faults & limitations future corrections (update) *sp4*


Unless otherwise indicated, the following faults will be corrected, if
possible, by the time of the next service pack.

Reference

Description

Module

Although use of international languages has been


improved for PDMS 11.6 & 11.6.SP1, there are still
various issues to be addressed in PDMS 12.

General

(1533)

PDMS cannot, in general, handle spaces in file


names or directories. This is due to the way in
which its commands are processed and cannot
easily be resolved, without some incompatibility.
Changes are being considered for PDMS 12.

General

(3777)

Centreline length output to file is incorrect in


Imperial (English) units.

Isodraft

(4366)

The extract control form did not handle deleted


sites correctly and cannot delete a site if one or
more sites are controlled by a DAC.

General

(4509)
(4510)

The Equipment application Option list selections


are not handled correctly. Planned for PDMS 12.

Design

(4863)

Under some circumstances, the General Model


Editor handle is incorrectly used in place of the
Pipe Component Modification handle. Planned for
PDMS 12.

Design

(5087)

The use of proportional fonts makes some screen


reports difficult to read: they will be changed to use
columns. An alternative is to produce a text file and
then view that.

General

(5285)

Member elements are not always correctly moved


Design
when a PNODE is moved or rotated. Improvements
have been made to positioning but rotation is still
not correct. Planned for PDMS 12.

HPD 28284
(6989)

PDMS sometimes runs slowly when using a thin


client implementation. This is being investigated
but can be improved by placing PMLLIB on each

VANTAGE PDMS Version 11.6.SP5


User Bulletin

Design
(and

11-2

Product Faults and User Requests

Reference
(9023)

Description

Module

client.

elsewhere)

No clash is detected with an XGEOM (laser model


point cloud) with no spatial occupancy map and
no warning is given.

Design

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-3

Product Faults and User Requests

11.2 Faults corrected and minor enhancements


This section briefly describes some of the most significant corrections and
improvements since PDMS 11.5 but not necessarily documented
elsewhere. Many of these will have been back-ported to earlier releases:
where this information was available at the time of writing, this is noted.
Please note that this list is not exhaustive: many other minor corrections
have been made. Users responsible for raising specific Software Change
Requests (SCRs) resulting in changes to PDMS should already have been
notified individually.
N.B. References in (brackets) are AVEVA internal numbers.

Reference

Description

First
Released

HPD 17392
HPD 17432
HPD 15676

Performance improvements on entering Design.

Design
11.5.0.1

Corrected setting of back references on CRFAs.

Full Service See User Bulletin for details:


pack
Updated AISC steel profiles catalogue to
Version 3.01.

Admin MDB Form performance enhancements

DABACON default buffer size increased

Nominal BDIA and BLEN for Bolts and


Hangers

Units option for height input to SPECON

Upwards of 50 minor improvements & fault


corrections

PDMS
11.5.SP1

HPD 14056

A set of gridlines (modelled by SCTNs with null


SPREF) was drawn if the only content of a View
but could disappear when other Design items
were added.

Draft
11.5.SP1

HPD 18376

Selection of a SCTN and then Goto>SPREF from


the members form used to navigate using the
SPREF NAME rather than the SPREF reference.
This caused incorrect navigation in the unusual
case of multiple SPREFs with the same name in

Design
11.5.SP1

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-4

Product Faults and User Requests

Reference

Description

First
Released

the MDB this is now corrected.


HPD 18378

Corrected a spurious error condition when


deleting members of a ZONE, when DACS are on,
using Delete>Members >All.

Design
11.5.SP1

HPD 21137
(3701)

The numbering of spool drawings that did not


start at a GASK or FLAN has been corrected.
This could lead to unset BOLTPARTNUMBERS.

Spooler
11.5.SP1.1
Isodraft
11.5.SP1.2

HPD 18208

Ability to add MTOLENGTH on a case by case


basis

Design
11.5.sp1.3
Isodraft
11.5.sp1.3

HPD 20676
(3683)

Wireline representation was faint with some


Design
graphics cards. This has been resolved by making 11.5.sp1.4
anti-aliasing (introduced at PDMS 11.5) optional.
It is now off by default but can be turned on by
setting the environment variable
SGL_ANTIALIAS=ON

HPD 16464
HPD 15743

No longer leaves phantom users in DARS and


design

DARs
11.5.sp1.5

HPD 22854
(3883)

Upgrading a project directly from 11.2 did not set


the database extract number

Admin
11.5.sp1.6

HPD 21916
HPD 22215
HPD 22899
HPD 22729

Flanges on the upstream and downstream side of


a component with MTOC and MTOT attribute set
to DOTU or DOTD are no longer flipped.
Flanged tees in the material list with the same
code and bores had different entries in the
material list but only one part number on the
isometric
Weld Bores were not shown as Nominal Bores on
the weld table when using Imperial Bores.
Spooler part numbering now checks LOFF to
ensure that OLETs do not split implied tube into
2 parts.
When the "MTOC" attribute is set to DOTD on
flanges, the bolt item was still created in
"COMPIPE" export file, even though it was not

Spooler
11.5.SP1.7
Isodraft
11.5.SP1.7
Isodraw
11.5.SP1.7

HPD 21274
HPD 22017
(3938)
HPD 22534

VANTAGE PDMS Version 11.6.SP5


User Bulletin

Isodraw
11.5.SP1.8

11-5

Product Faults and User Requests

Reference

HPD 23077

HPD 23143
(4011)
HPD 18109
HPD 23699
HPD 23868
HPD 21581

HPD 23772
(4190)
HPD 23891
HPD 24237
HPD 23756
(4249)
HPD 24305

(4353)
HPD 24095
HPD 24526

HPD 23649

Description
shown on the isometric drawing
Corrected wrong dimension (OLET TEE) if a
Text ATTA and a WELD have the same position
and an OLET is the previous fitting.
Panels & Plates application amended to create a
single penetration for a section through a panel
correctly.

First
Released
Isodraw
11.5.SP1.9
Design
11.5.SP1.10

Corrected fault in restoring display from binary


dump files.
Enhanced drawlist query (for MDS).
Tapered SCTNs with SPREF containing SREC
geometry were drawn prematurely shortened if
the tapering was more than around half the
original size.
Desclash now correctly records long names for its
clash reports.
Corrected Desclash failure with a very large
obstruction ( >20M in X, Y, Z axis)

Design
11.5.SP1.11

Partnumber now 0 for bend with SKEY TB*D


Bolts now correctly reported at out of spec valve
to nozzle (no gasket) connection
Corrected transformation applied to the graphics
of OLAY elements when these were defined by
external plotfile - potentially affected DXF &
DGN file export from DRAFT.
Pseudo attribute DACMOD did not work when
used within a collection

Design
11.5.SP1.13

Corrected operation of extracts: it previously


caused a DICE check to give the message:
Element n has an inconsistent entry in the name
table. Name exists in the table but a different
name exists on the element.
This was caused by renaming an element in an
extract, creating another element with the
original name and then flushing or issuing the
renamed element.
Global Extract Flush/Issue/Release used to lead to
inconsistent errors due to only part of a command

Design
11.5.SP1.14
Draft
11.5.SP1.14
Admin
11.5.SP1.14

VANTAGE PDMS Version 11.6.SP5


User Bulletin

Design
11.5.SP1.12

Draft
11.5.SP1.13
Isodraft
11.5.SP1.13

11-6

Product Faults and User Requests

Reference

Description

First
Released

being executed when the local daemon was not


running. PDMS did the child extract action, but
the parent extract action was lost. Following
Flush/Issue commands failed with a 613; Releases
had inconsistent claimlists resulting in error
messages:
Element n needs clearing from extract from
claimlist in parent extract.
Element n needs to be marked in parent extract,
as being claimed to this extract in parent extract
Element n is claimed to extract n, not a child
The child part of the extract is now undone if the
local daemon is not running. The command will
have to be resubmitted once the daemon is back
up.
HPD 24817

HPD 20482
HPD 22731
(3834)
HPD 24054
HPD 25141
HPD 23330
HPD 24636
(4709)

DICE reported a corruption where an element


was not registered in its owners member list:
Element =n/n is not in the member's list of its
owner =n/n
For example, this sequence:
In Master
Create /PIPE1
Create /BRAN
In Extract
Create /PIPE2
Move /BRAN to /PIPE2
Flush /BRAN
Meant that /BRAN was not in the member list of
/PIPE2.
DICE can now patch this fault.

Design
11.5.SP1.15

Axes and element name (Query>AXES option) are


now correctly displayed on the graphical view,
even when clipping is turned on.

Design
11.5.SP1.16

Draft
11.5.SP1.15
Admin
11.5.SP1.15

Print view distorts the view on the printer


Updating or checking numbering of a SPLDRG
results in termination with DB error 41

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-7

Product Faults and User Requests

Reference

Description

First
Released

HPD 23773
HPD 25939
(4756)
HPD 25723

Amended relative movement form when used


WRT element itself.

Design
11.5.SP1.17
Isodraft
11.5.SP1.17

HPD 25083

HPD 25860
HPD 25563

Position Explicit (AT) with LOAP gave the


following incorrect error message:
(2,211) Attribute ORI cannot be evaluated for
LOAPOINT /1210-10-1/ANCHOR - max.level of
nesting exceeded'
Q P1 BOLT TOTAL did not work with one branch
with a flange connected to PTAIL and a second
branch connected to the first. The second branch
had a gasket and flange connected to PHEAD.
Choose form did not output HEIGHT values with
the correct units
Selection of Tee with ARRIVE 3(!) and LEAVE 1
or 2 sometimes incorrectly gave error message:
(61,164) SPEC does not contain elements
matching given criteria.

(3123)

Database 'Marks' are now cleared by GETWORK

11.6.SP2

HPD 22229

Global Extract ranges could not be applied using


the GUI.
Corrected Expunge User Process form: the date
was incorrect for most of the entries.

Admin 11.6

Corrected occasional WIGWAM Primitive Group


overflow (error 21) typically on company logos
composed of 1000s of STRAs. (SKE ORIG ALL IN
gid or SKE POIN ALL IN gid).
RENAME text gadget on COPY form now works
correctly with or without the / preceding the
name.
#PROJ^DESC corrected for Global projects.
DATE field now correct when creating e a DRWG
from a TEMPLATE.
Code words such a #P^POS & #PK^POSS did not
work for TEXPs of VNOTs.
Customer specific set-up file for configured DXFoutput did not correctly set up DRAFT Utilities >
DXFout > Configured.

Draft 11.6

HPD 26241
HPD 15174

HPD 20154

HPD 22250
HPD 24115
(4153)
HPD 26286

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-8

Product Faults and User Requests

Reference

Description

First
Released

HPD 11795
(3277)

The Export of some panels to Review was


incorrect, so they appeared black. This was due
to an incorrect calculation of the normal to the
end surface of extrusions, which now always point
outwards.
List Gadgets now correctly grey out when
inactive.
Q MTBE or Q BRCOG used to crash with
DABACON 18 error when the CE was implied
tube of hanger.
3DView.shaded boolean now returns correct value
Copy with Offset form failed to display if it had
been used to refer to a deleted element: it now
defaults to /*.
Error fixed that caused syntax error when
modifying the position line or joint line of a joint
(MODIFY>JOINTS>POSITION LINE).
Macro error corrected for Modify>Joints>Joint
Like.
Corrected macro error for
ModifySectionsMerge and then selecting
Sections in List.
Trying to modify the position line of a fitting on a
section gave syntax errors in line 119 of Macro
%PDMSUI%/DES/CLIB/GPLINE
Tidy Gtypes macro on SCTNs with template
fittings gave errors:
(2,752) Array element 7 does not exist
In line 49 of Macro
%PDMSUI%/DES/STLWRK/MSETGTYPE
A steelwork joint with an associated plotfile but
no editable properties now correctly displays the
plot.

Design 11.6

Error removing weld symbol from FLANGE when


P-point 2 PSKEY set to PLAIN.
Incorrect continuation nozzles no longer drawn
when using FTUBS
ISODRAFT now handles explicitly set BTHK

Isodraft
11.6

HPD 14470
HPD 18365

HPD 19125
HPD 22572
(4013)
HPD 23149

HPD 24304
HPD 24504

HPD 25367

HPD 25368

HPD 26863
HPD 18490
HPD 24072
HPD 25430

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-9

Product Faults and User Requests

Reference

Description

(5508)
HPD 26118

values of BLTPs of BTSE for wafer components.


Using universal keys caused a splash fatal error
in certain cases.
Redefinition of Spec Break ATEXT caused
information to be missed off drawing.
See Remedy call for details. Isometrics with no
material list had incorrect spool numbers with
Spool Number PREFIX *K
EXTRACT CLAIM LATEST gets the latest
claimlist for all writable DBs. This entails going
through a share lock on each DB.

HPD 26213
HPD 26562

HPD 15643
(2985)

First
Released

General

For large projects this can be time-consuming so


the syntax has been extended to allow:
EXTRACT CLAIM LATEST DB <dbname>/ALL
and allow specific db to be given.
In ADMIN it is no longer permitted to say just
EXTRACT CLAIM LATEST specifying a db is
compulsory. Elsewhere it is optional.
HPD 14636
(3399)

Improved performance when merging large


number of sessions.

General

HPD 18268
(3402)

OUTPUT now correctly adds quotes when an


STEX string begins with ( .

Paragon

(3413)

Increased the max insulation thickness from 150


to 300mm.

Design

HPD 18402
(3420)

Now handles a user doing PARTNO CREATE CE


when another user has just created the spool
drawing & still has it claimed.

Spooler

HPD 18641
(3431)

The following pseudo attributes may not be used


in catalogue expressions:
ATLE, LTLE, AGRD, LGRD, FITLEN, MTLE,
STLE, STAP & MTCL.

Design

Use of ATLE previously caused a crash in Design


when the item using such a ppoint was drawn.
HPD 18874
(3464)

CONN PH to P4 of /PAD4 now correctly sets


CRFA of /PAD4 if initially unset.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

Design

11-10

Product Faults and User Requests

Reference

Description

First
Released

(3520)

Element with duplicated names in two extracts of


the same database caused problems on flushing
back to the parent database.
Data listings are now always output in forwards
mode: previously numbering could get confused.

Design 11.6

HPD 18959
(3529)

Design

HPD 14758
HPD 16772
(3541)

Resolved a problem with Report formatting with


Design
subtotalling. If a value results from several values
being subtotalled, then it no longer appears on a
new line in the report.

HPD 20176
(3628)

Modify>Sub Equipment Origin>ID Point now


clears the SUBE name is after the user accepts
the location of new origin point.

Design

HPD 20222
(3648)

Text strings in DXF output are no longer limited


to 128 chars, as expanded text from DRAFT can
be up to 180 chars.

Draft

HPD 20167
(3651)

UDAs with non alpha names now work in PML2


expressions, e.g.

General

!XX = !!CE.:UDA-LIST
HPD 19946
(3653)

The ACBORE on a CMPD is no longer treated as


a nominal bore, so when set to 38.14 it is not
changed to 40!

Propcon

HPD 20364
(3660)

Query !!ce.inth now returns ZERO (0) were


insulation is unset for a component.

Design

HPD 20798
(3682)

Q BRWEI no longer crashes if the CE is a pipe


which owns restraints.

Design

HPD 20968
(3699)

!X = !!CE.PTCDIR now works correctly.

General

HPD 21379
(3724)

RESELECT now works for tees & reducers

Design

HPD 21328
(3809)

Data output command no uses a greater precision


(1/8192) with FINCH DIST.

Design

HPD 22751
(3837)

PDMS no longer crashes when the Explorer ADD


CONNECTED option is used with the connected
branch deleted.

Design

HPD 23033

Several improvements have been made to the

Design

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-11

Product Faults and User Requests

Reference

Description

HPD 23039
(4008)
(4009)

behaviour when creating and modifying ring


GENSECS, using the Create Ring and Modify
Section (Ring) forms.

HPD 23041
(4010)

Deletion of CURVE element of SPINE using


Modify Section (Curve) form produces error
message and does not complete deletion.

First
Released

Design

If a CURVE element is deleted using the Delete


button on the Modify Section (Curved) form an
error message is displayed, see attachment, and
the deletion is not carried out.
HPD 22577
(4012)

If you set the frame of reference to the SCTN that


you are trying to move, the resulting position is
no longer incorrect (by a long way!)

Design

(4033)

A number of improvements have been made to


SP1 to ensure that a list, option gadget and
textbox with the same width specified in the form
definition now have the same overall width.

General

Many other improvements have been made to


forms & menus layout, visibility etc.
(4062)

HPD 23467
(4084)

With 2D views, the arrow keys seem to be locked


to the horizontal scroll bars and do not work
properly.
Lists/Collections form, using Add>Selection

GUI

General

ALL types no longer outputs a syntax error.

HPD 23523
(4106)

Dice can now patch the case where elements have


been lost from the member list of their owners.

Admin

HPD 23609
(4117)

Error D800 is now included in the Design Ref pt 4


manual.

Design

(4186)

Dice now outputs highest session number.

Dice 11.6

HPD 23891
(4206)

Clashes are no longer missed when a very large


object is checked against a small obstruction item.

Design

(4300)

Dice no longer crashes on corrupt database

Dice 11.6

HPD 24095
HPD 24526
(4408/4410)

Out of sync name tables (possibly caused by a bug


in extract flush) are now patched by Dice.

Admin 11.6
11.5.sp1

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-12

Product Faults and User Requests

Reference

Description

First
Released

(4430)

Problem opening these other Databases will no


longer cause DICE to fall over.

Admin 11.6

(4433)

MODE FULL and MAXERROR of 0 are now the


default settings on entry to Admin.

HPD 24237
(4346)

There is now no Partnumber for bend with SKEY


TB*D

Design

(4474)

Correct precision now displayed in GUI for


imperial units.

Draft

HPD 24998
(4543)

Options>Modify form: Select Component Tags


now includes FILT.

Isodraft

(4568)

The Head and Tail type markers do not resize


during an align with feature operation when the
view is zoomed in.
The View manipulation for the Draft 3D View
window has been improved for SP1.

Design

HPD 19944
HPD 18705
HPD 24431
(4757)

Amended unwanted clipping when rotating the


view around an element.

Design

HPD 24648
(4760)

When adding Routing Planes as a constraint to a


branch, the form in Design now shows all the
RPLAs in the MDB, not just the current
database.

Router

HPD 24557
HPD 24531
(4761)
HPD 25281
(4783)

Global Stand alone Project creation using the


Admin
upgrade option adds unnecessary lines in inmacro
that creates a loss of catalogue references: the last
section must be removed for it to work correctly.
Modification of ACR GROUPS using the
Admin
application has been amended.

HPD 25293
(4804)

MicroStation (.DGN) files have been corrected to


enable DGN file export.

Draft

HPD 22623
(4819)

The case of an unset filename for File on the


DATACON form is now handled better.

Design

HPD 25357
(4874)

Corrected an error causing some primitives of a


catalog component to be omitted from the display.

Design

(4471)

VANTAGE PDMS Version 11.6.SP5


User Bulletin

Draft

11-13

Product Faults and User Requests

Reference

Description

First
Released

(SGL errors were also output)


HPD 24880
(4908)

The Utilities>Pipe penetration application no


longer leaves the aid axes behind.

Design

HPD 20192
(4918)

The Create Extrusion form no longer creates two


slashes (//).

Design

HPD 25539
(4919)

The Nozzle Specification (FNOZZPEC) form has


been amended.

Design

(4926)

Corrected a problem on entry to PDMS with


Korean MDB name.

Monitor
11.6

(4933)

Query>Project>DBs now gives correct details for


those with Korean names.

Admin

(4980)

Resolved a problem merging Extract Databases


containing sessions that point to a base session in
the owner. Previously an error meant that
running Dice on the Child Extract gave a Bad
Block FATAL error, with the rest of the database
not being checked.
Error in bolt querying corrected.

Admin 11.6

HPD 25083
(4994)

Design

Q P1 BOLT TOTAL did not always work correctly


with branches connected together.

(5015)

UNDO now works more reliably with the model


editor handle position.

Design

(5016)

Corrected an error with Project form for project


descriptions containing Korean characters.

Admin

HPD 25602
(5020)

An error causing memory to leak in PML (TCTL)


has been corrected.

Design

(5035)

The Reselect command is now available outside


the model editor from SP1.

Design

(5154)

With a sheet consisting of more than one view,


the preview for offset section planes is not clear.
Position>Explicit (At) Form corrected when used
with loadpoint LOAP.

Draft

HPD 25723
(5208)

The following error message used to appear:


(2,211) Attribute ORI cannot be evaluated for

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-14

Product Faults and User Requests

Reference

Description

First
Released

LOAPOINT /1210-10-1/ANCHOR max.level of


nesting exceeded.
(5212)

HPD 25563
(5228)

An AREADE element containing an ABOX does


not correctly copy it fails to copy the ABOX and
gives a misleading error message.
Resolved a problem with selection with a TEE
with ARRIVE 3(!) and LEAVE 1 or 2, using the
syntax:

Design

!Select = SELECT LSTUBE WITH SHOP TRUE


(5284)

A docking form that is undocked will not show


ToolTips on pixmap buttons.
Can now save the Define Purpose file using the
SaveAs option.

GUI

HPD 26241
(5382)

Correct dates now shown on the Expunge User


Process form.

Admin

HPD 22229
(5384)

When setting the Global Extract range for an


uninitialised location, the user is asked if he
wants to initialise the location. A No answer is
now handled correctly.

(Global)
Admin

(5387)

The list gadget allows data as strings to be added


as columns separated by a TAB character. The
expression object used for columns, tables and
report objects at SP1 allows the tab character to
be used so that the data can be added directly to a
list from a table/report.

General

(5427)
(5428)

Some PDMS blocking forms prevent the user from General


accessing other applications, including MS Office
etc.
If the ADMIN/PADD DB is deferred when the
Draft
user tries to display the 3D View window, Draft
would crash with Dabacon 41 error. This is
handled properly in SP1.

(5370)

(5459)

(5550)

The + and - keys have been implemented in SP1


such that + increases the offset or clearance from
the plane defined by the feature, - decreases this
value.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

Design

Design

11-15

Product Faults and User Requests

Reference

Description

(5555)

An error when producing Check ISOs of unnamed Design


spool elements has been corrected.

(5559)

Correction of an error causing the message


(2,751) Variable !!REALFMT does not exist
when querying attributes.
Certain changes are treated incorrectly during
reconfiguration of extracts
Direction of movement of a component at the tail
of the branch using the GUI has been corrected.

General

(5698)

Resolved a problem when flushing any element


would result in a Dabacon 534 error.

General

HPD26626
(5704)

The default value DPRO is now used to evaluate a Design


text property. It is used for the real equivalent
RPROP.

HPD 27087
(5716)

A correction has been made to avoid an incorrect


message:
(99,532) Undefined UDA name
when using long uda names.

(5719)

Form now tracks the problem item on the Data


Consistency Form.
Correction to allow concatenation of a method to a
UDA value.

Design

(3287)

DICE now increments the session when it patches


a database, thus ensuring that Global correctly
recognises and distributes any necessary changes,
including claim lists.

Dice 11.6.0

(5791)

Invalid entries in name tables (i.e. invalid


references) are now corrected if possible.
A partial flush will now ignore any invalid table
attributes and carry on.

Dice

(5613)
(5625)

HPD 27082
(5726)

(5793)

VANTAGE PDMS Version 11.6.SP5


User Bulletin

First
Released

Admin
Design

General

General

11-16

Product Faults and User Requests

11.3 Faults corrected and minor enhancements

*sp1*

Please note that this list is not complete: many corrections were made to
faults discovered during internal testing and early evaluation. Some of
these may also have been back-ported to earlier releases.

Reference

Description

Module

HPD 23235
(4130)

The axis is no longer left the object being


created/modified after leaving the HVAC
application.

Design
11.6.sp1

HPD 25543
(5051)

Export does not export leave rod from hangers.

Design
11.6.sp1

HPD 26315
(5406)
HPD 26936
(5680)

Wigwam overflow crashes with a very large


number of EXTRUsions or error messages, e.g.
Error 21s (Primitive Group too long) from
GOPPLN, when drawing large models created
using ImPLANT. Existing checks need to be
extended. Splitting or simplifying the model will
usually help.

Draft
11.6.sp1

HPD 26447
(5477)

Connect button is no longer greyed out to prevent


connection of ph to first mem after it was
connected to a PT.

Design
11.6.sp1

HPD 26802
(5625)

Creation of a component starting from the tail of


the branch with a spool between the TAIL and
the component now goes in the correct direction.

Design
11.6.sp1

HPD 26863
(5634)

A steelwork joint with an associated plotfile but


no editable properties will no longer have the
plotfile button greyed out on the Joint Spec form.

Design
11.6.sp1

HPD 22396
(5725)

Corrected a possible SPLASH crash for GLAB (&


probably SLAB) with invalid DDNM when
repositioning using command AT @.

Draft
11.6.sp1

HPD 27043
(5732)

Text evaluation of a selection now adds brackets


around a VTEXT variable.

General
11.6.sp1

HPD 19575
(5754)

Modify>Component>Connection Ref. now works


correctly for a CROS.

Design
11.6.sp1

HPD 23235

The axis is no longer left at the object being

Design

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-17

Product Faults and User Requests

Reference

Description

Module

(4130)

created or modified after leaving the HVAC


application

11.6.sp1

HPD 19243
(5756)

Access control methods are now properly invoked Draft


before creating a ADDE/REME element, ensuring 11.6.sp1
that the ADD command does not create a new
ADDE under an IDLI when it is not claimed.

HPD 27197
(5747)

Component selection form no longer shows an


error if component is in LIMBOSPEC

Design
11.6.sp1

HPD 19602
(5752)

Settings>Storage Areas option Create>Level


brings up the buildings level form: this now
works better if the Apply button is used without
giving a name.

Design
11.6.sp1

HPD 19630
(5763)

A PML error caused by deletion of the PLOO


element of a rectangular panel has been
corrected.

Design
11.6.sp1

HPD 27430
(5775)

Resolved problem of losing the temporary


graphics after popping up the modify labels menu
if the cursor is off the graphics window.

Draft
11.6.sp1

HPD 26914
HPD 27671
(5780)

Corrected quantity for bolt material if there are


more than 100 bolts in one flanged connection.

Isodraft
11.6.sp1

HPD 27469
(5800)

Corrected a calculator error when using Delete


range of piping components button in imperial
units.

Design
11.6.sp1

HPD 27468
(5801)

A correction has been made for mixed pipe bore


handling when using Quick Pipe Router.

Design
11.6.sp1

HPD 27553)
(5764/5809)

Datal output for "BACK" now correctly outputs


certain cascaded attributes such as SIZE, XYPS
if they are set.

Draft
11.6.sp1

HPD 27472
(5811)
HPD 27766
(6697)

Improved equality check for two PML variables of General


data type BORE. This means that components
11.6.sp1
will be correctly matched.

HPD 27191
(5817)

Member .detail of AVEVA object GPHPOSITION


corrected to work with Imperial FINCH units.

Design
11.6.sp1

HPD 27893

Plotfiles in tabbed frames no longer make PDMS

Design

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-18

Product Faults and User Requests

Reference

Description

Module

(6707)

crash or hang.

11.6.sp1

HPD 27884
(6708)

It is no longer necessary to set dock or anchor for


tabbed frames to create a scrollbar, as they are
now treated as Dock Fill.

Design
11.6.sp1

HPD 27883
(6709)

It is now possible to give tabbed frames tags after


they have been created.

Design
11.6.sp1

HPD 27882
(6710)

It is now possible to make tabbed frames


invisible.

Design
11.6.sp1

HPD 27946
(6729)

Branch weight of first tubi now gives correct


weight.

Design
11.6.sp1

HPD 27956
(6734)

comPropData.pmlobj corrected for nozzles

Design
11.6.sp1

HPD 27987
(4422)
(6741)

Unhandled Exception error message is no longer


when Auto-hide option is used on the Command
Line.

Monitor,
Admin

HPD 27623
(6763)

PDMS will no longer crash when checking pipe


with missing references on hangers.

Design
11.6.sp1

HPD 16869
(6774)

Correction for tube weights in material list.

Isodraft
11.6.sp1

HPD 28142
(6786)

If PML discovers an incomplete DO loop on an


ENDMETHOD, it now issues an error message
as well as tidying up.

General
11.6.sp1

HPD 28030
(6829)

Picking of REST/HANG elements now works


correctly when representation for insulation is
set to translucent.

Design
11.6.sp1

HPD 28292
(6834)

Corrected a problem closing sheet, after a


deletion. This led to an error messages
(2,109) Undefined name
and afterwards
(47,15) CP: Syntax error
for any activity.

Draft
11.6.sp1

HPD 28331
(6840)

Components created using the new component


creation form will no longer always have the
SHOP set to FALSE, regardless of the spec.

Design
11.6.sp1

HPD 28434
(6875)

Improved visibility of Zoom box on plot view.

Isodraft
11.6.sp1

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-19

Product Faults and User Requests

Reference

Description

Module

HPD 28280
(6879)

Setting obstruction to anything but OFF no


longer makes all the steel section disappear.

Design
11.6.sp1

HPD 28394
(6886)

Correction to allow the steelwork joints on the


MTO.

Draft
11.6.sp1

HPD 28478
(6893)

Corrected an error when LOCKing the WORLD!


No longer gives a Runtime error with the error
message 'Unhandled Database Error 10 from
DGOTO, invalid external reference'

Draft
11.6.sp1

HPD 28515
(6906)

Moving a branch no longer navigates to a


different element.

Design
11.6.sp1

HPD 28528
(6923)

PRESSURE and TEMP are not showing on the


iso properly; they are being converted with the
UNIT (showing as FEET and INCHES).

Isodraft
11.6.sp1

HPD 28407
(3525/6924)

Improved the speed of GETWORK in Draft.

Draft
11.6.sp1

HPD 28587
(6925)

Resolved text problems with Cyrillic fonts in DXF


output.

Draft
11.6.sp1

HPD 23469
(6972)

Corrected an error in the description for 1" 90deg


elbows.

11.6.sp1

HPD 23470
(6973)

Corrected various problems with Spec Breaks:


1. At some breaks no break marker boxes were
shown.
2. Only one marker box was shown at CONT.ON
(REC -30).
3. Marker for a single spec instrument was
missed out.
4. In some cases, the lines for the positioning
were too long.

Isodraft
11.6.sp1

HPD 28468
(6990)

Corrected a problem with the component mouse


pointer when using modify mode to rotate or
move a piping component.

Design
11.6.sp1

HPD 28583
(6993)

The case where a JOIS or JOIE attribute on a


SCTN element was an invalid ref (as correctly
noted by DICE) was not being handled by
CHECK (Datacon). This situation is now trapped,
and an error 'Structural Geometry Error - JOIS
(/JOIE) reference invalid' will be produced.

Design
11.6.sp1

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-20

Product Faults and User Requests

Reference

Description

Module

HPD 28470
(6996)

Modify Mode now correctly moves the Pipe Head


or Pipe Tail, when there is a connection across a
pair of flanges.

Design
11.6.sp1

HPD 28762
(7162)

Itemcode from UDA now works correctly when


the number of UDAs exceeds 30.

Isodraft
11.6.sp1

HPD 28912
(7173)

Utilities > Export > Dump Attributes utility now


works correctly when is a BRAN component that
has an unset or bad SPREF.

Design
11.6.sp1

HPD 28933
(7298)

Creating Corner Posts with the ASL Modeller


application now locates the corner posts correctly
with an imperial project.

Design
11.6.sp1

HPD 28965
(7398)

Can now modify floor fittings.

Design
11.6.sp1

HPD 27131
(7520)

Module switch will no longer crash when there is


an instance of user defined object with member(s)
of type EXPRESSION.
PML will now not attempt to save any objects
which have any C++ members, such as the
Expression object. This is because any such PML
object is not saved over a module switch.

General
11.6.sp1

HPD 28477
(7539)

Q BREARE now gives the correct result for a


TUBI after a REDU.

Design
11.6.sp1

HPD 28477
(7661)

Highlighted elements are no longer displayed


Design
wrongly.
11.6.sp1
Formerly, if you identified a portion of tube in the
graphical view and then moved to another item in
the view, the portion of line that you have
identified previously would change to dotted (in
wireline) like there is an error on that portion of
pipe.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-21

Product Faults and User Requests

11.4 Faults corrected and minor enhancements

*sp2*

This lists the most important corrections in Service Pack 2, at the time of
writing (October 2005).

Reference

Description

Module

HPD 16305
(2879)
HPD 29325
(7908)
HPD 29632
(7929)

Dice sometimes incorrectly showed errors in large


Dabacon tables.

Dice
11.6.sp2

(3418)

Pline Definition window now correctly displayed


Paragon
on selecting Modify mode, deleting the created
11.6.sp2
Pline and then re-calling the form in Create mode.

HPD 23332
(4127)

A POHEDRON of zero thickness now Exports to


Review correctly.

Design
11.6.sp2

(4495/8458/
8229)

Dice now correctly handles errors in tables due to


corrupt data, rather than crashing.

Admin
11.6.sp2

HPD 24925
(4758)

Corrected an error causing report templates to


fail thus:

Reporting
11.6.sp2
(also fix for
11.5)

WARNING Data too long for variable. Data


truncated.
This was due to inconsistent limitations in
passing arguments between macros.
(5254)

Form layouts improved, e.g. relative offset

Design
11.6.sp2

(5377)

Exception error when using UNDO and Quick


Pipe Router

Design
11.6.sp2

(5457)

Relative move form now shown correctly after


deleting equipment

Design
11.6.sp2

HPD 30534
(6711/8171)

Many improvements were made to robustness,


when used on damaged databases, including:
Deletion of a primary element in a master
database could lead to errors when modifying it in
a variant.

DICE
11.6.sp2

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-22

Product Faults and User Requests

Reference

Description

Module

HPD 29571
(7999)
(6728)

Option to allow a partial flush to work with


deleted elements with the same name.

11.6.sp2

HPD 25316
(6757)

SKEYs WLR and WLC have been added for use to


show lugs. The default symbol for both is the
same as a NIPL OLET, but without the bore data
and elevation messages.

Isodraft
11.6.sp2

HPD 25340
(6981)

Limitation in DACs condition setting form


corrected.

Admin
11.6.sp2

HPD 27267
(7089)

Modifications to prevent excessive database


growth during issuing or flushing.

(Dabacon)
11.6.sp2

HPD 29068
(7431)

Group reference list now allows for element


appearing more than once caused crash

Design
11.6.sp2

HPD 29217
(7589)

Corrected spurious cut length number for elbow


upstream welded attachment.

Isodraft
11.6.sp2

(7670)

Plines can now be highlighted or selected on


Gensecs, as on Sections.

Design
11.6.sp2

(7709)

Pipework Pipe Component Selection form now


shows Spec correctly after a change.

Design
11.6.sp2

HPD 29394
(7768)

Corrected OLET Item Numbers display in the


isometric graphics area, for specific options
including user defined columns.

Isodraft
11.6.sp2

HPD 29404
(7769)

New option to suppress continuation notes, giving


the number of the sheet, across sheets of a
drawing. This command controls only the arrowed
continuation message; other aspects of the
continuation are unchanged. Examples:
CONTS OFF: Continuation notes between sheets
are suppressed.
CONTSHEET ON: Continuation notes between
sheets are switched on.

Isodraft
11.6.sp2

HPD 29415
HPD 29847
(7777/7990)

Corrected Dabacon error 23 or 10 on flushing an


extract Database containing differing length
UDAs.

11.6.sp2

HPD 29468
(7804)

The customary warning when a licence is due to


expire shortly is now working again.

General

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-23

Product Faults and User Requests

Reference

Description

Module

(7807)

Pipe and branch names are now displayed


correctly in the Component Creation form

Design
11.6.sp2

(7808)

Bore text is now displayed correctly in the


Component Creation form

Design
11.6.sp2

HPD 29292
(7699)
(7813)
(7814)
(7818)
(7828)
(7833)
(7847)

Bores are now correctly handled for both imperial


and metric projects when creating components.

Design
11.6.sp2

HPD 29556
(7877)

Clashes are not detected if implied tube is badly


aligned, i.e. is shown dotted in the 3D graphics, as
it is not included in the spatial map. Under some
circumstances, this could be misleading: for
example, if different tolerances are used for
drawing and for building the map. Rather than a
bad alignment message, new D860 & E860 (for
Arrive & Leave tube) error messages are now
issued when data checking when the tube is not
in the map. These state:
TUBE DOES NOT EXIST IN THE SPATIAL
MAP, NO CLASH WILL BE DETECTED

Design
11.6.sp2
(also
11.6.sp1.5)

(7888)

An error causing an exception when using the 3D


view has been corrected. Features were not being
rotated with the model, so they appeared in the
wrong place, and could not then be associated
with the model. Placing the cursor in the 3d
window then caused a crash.

Draft
11.6.sp2

(7894)

An attempt to rotate a deleted selection will no


longer cause an Unhandled Exception error.

Design
11.6.sp2

(7895)

Labels now snap to the origin of the label in


modify mode with snap to grid turned on.

Draft
11.6.sp2

HPD 29591
(7915)

Resolved Dabacon crash with certain data when


querying PQAANG this caused a Runtime
Error when Branch Reconnection or Data Check
was carried out.

Design
11.6.sp6
(and
11.6.sp1.1)

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-24

Product Faults and User Requests

Reference

Description

Module

(7917)

Use of model editor on HVAC branch no longer


causes a null reference exception error.

Design
11.6.sp2

(7918)

Resolved occasional exception error, due to


operations being attempted on a closed 3D view.

Design
11.6.sp2

(7919)

Various uses of the Reference Definition


Application form while in Model editor mode
caused a run time error. These have been
corrected.

Design
11.6.sp2

HPD 29726
HPD 29860
(7939)

Corrected poor form layout when using some


Asian languages

Design
11.6.sp2

HPD 29529
(7945)

Improved Equipment Positioning on Panel


surfaces.

Design
11.6.sp2

(7951)

Resolved a fault causing Dabacon errors such as


Unhandled Database error 41 in Extract
databases.

11.6.sp2

HPD 29776
(7965)

Resolved ERROR in SPLASH routine HADDIA


when detailing an Equipment Trim.

Isodraft
11.6.sp2

HPD 29886
(8017)

SPLASH Error in routine HGETI1 when floating


a second Graphics window has been corrected.

Design
11.6.sp2

HPD 29206
(8048)

The PREPROCESS and POSTPROCESS


commands have been modified to use the
maximum string length of 250 characters before
processing, e.g. for embedded quotation marks.

Isodraft
11.6.sp2

(8052)

Corrected spurious message: (160,9) File


%PDMSUSER%/frame-coords.txt does not exist.
This occurred on the first attempt to list the
attributes of an element in the explorer.

Design
11.6.sp2

HPD 30077
(8147)
(8206)

System incorrectly called for Final Designer


license feature. This also caused many errors in
the log-file when there was no such license.

Draft
11.6.sp2

(8162)

Corruption in Name table now prevented when


name of element (deleted in variant) is re-used in
owning extract.

11.6.sp2

(8183)

Dice will now correct reports errors of the form:


Next bucket is 6 but bucket 6 found in extract 3.

Dice
11.6.sp2

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-25

Product Faults and User Requests

Reference

Description

Module

(8184)

Crash in Dice when doing a check db with patch


on.

Dice
11.6.sp2

(8208)

Extracts no longer created with wrong team using


Admin GUI.

Admin
11.6.sp2

(8221)

Resolved a fault causing Dabacon error 41 when


doing "extract refresh.

11.6.sp2

(8228)

Entries were being left in the Spatial Map when


elements no longer existed: a Dice check reported
this problem. Now handled correctly.

11.6.sp2

(8233)

In a global project, all changed extract files must


be propagated after compaction before databases
are used. To ensure this is done, Dabacon now
checks and handles this situation by checking the
compaction count.

11.6.sp2

(8246)

Co-fitting now correctly applies referenced


negative geometry, when splitting a panel.

Design
11.6.sp2

(8306)

A SBFI (sub-fitting) can use the ARRIVE


attribute to specify a P-point of the owning CMFI
(compound fitting) to alter the frame of reference
for its geometry and orientation. In this case, the
system now correctly uses the design points of a
CMFI defined as a TMPL in place of the P-points
of one using a catalogue definition.

Design
11.6.sp2

(8308)

The EDG measure utility now works correctly


when in graphics mode.

Design
11.6.sp2

(8328)

In certain circumstances, the Commands form


'Request' panel became 'see-through' now
corrected.

Design
11.6.sp2

(8360)

Dice now handles transaction databases better, to


avoid misleading error messages due to the
databases growing whilst DICE is running its
checks.

Admin
11.6.sp2

(8383)

Corrected a fault with linear grids, causing a run


time error when clicking any point on the dotted
line.

Design
11.6.sp2

HPD 29073
HPD 30189

Clicking on a ROD element no longer causes a


crash after a message Unhandled Exception:

Design
11.6.sp2

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-26

Product Faults and User Requests

Reference

Description

(8376)

System.NullReferenceException.

HPD 30284
(8427)

Certain PML forms could cause an error (61,564)


F&M Cursor functions not allowed during
Tracking updates is raised and then a program
crash. This did not happen at PDMS 11.5. The
error will now be trapped properly.
This was caused by a form with Tracking on
executing a cursor function from a button and
causing the system to become recursive.

Design
11.6.sp2

(8446)

Under certain circumstances, claims were being


lost, resulting in the following DICE error:
Element ATTACHMENT /name needs to be
marked in parent extract, as being claimed to this
extract in parent extract

11.6.sp2

(8448)

Crash in MyData corrected. It was caused by


adding an element to MyData in one session,
changing the elements name in another session,
and then savework, getwork in the first session.
Dice no longer hangs, when encountering a
particular severe corruption in the sessions of a
database.

11.6.sp2

(8465)

Dice now copes better with databases containing


lots of 406 errors.

Admin
11.6.sp2

(8476)

Switching names on two elements no longer


causes corruption if done twice in conjunction
with flushwithout.

11.6.sp2

(8479)

Dabacon error 41 on deleting an extract now


handled correctly

Admin
11.6.sp2

(8504)

Dice now handles extracts missing at the current Admin


location differently. Previously, a DICE check on
11.6.sp2
a level 2 extract might give an error 'Unable to
search index table in extract 3' because Extract 3
was non-propagating, and therefore not present at
the current location. This error is now treated like
the 'Lost bucket' error in a global project, which
outputs a warning about non-primary databases.

(8464)

VANTAGE PDMS Version 11.6.SP5


User Bulletin

Module

Admin
11.6.sp2

11-27

Product Faults and User Requests

11.5 Faults corrected and minor enhancements

*sp3*

This lists the most important corrections in Service Pack 3, at the time of
writing (April 2006). In some cases, these may also have been made
available in fix releases for previous versions of PDMS.

Reference

Description

Module

(3887)

The Extract claim hierarchy form has been


improved: among other things, it now indicates
when a claim exists at a lower hierarchy.

Design
11.6.sp3

(4658)

Corrected display of Bore in Query>attributes form


for mm Bore units setting.

Design
11.6.sp3

HPD 24740
(4759)

Improved DACs error handling in several places in


the GUI by using a new test rather than a dummy
move (BY E 0 mm).

Design
11.6.sp3

HPD 28023
(7292)

This resolves a problem with the GUI when adding


an ATTA to a cable tray which contains a MDS
support.

(4915)
(8939)

Spooler no longer changes the session units.


Output dimensions and MTO units in Isometric
preview in Spooler are now shown in the current
session units.

Spooler
11.6.sp3

HPD 26603
(5591)

Query>General has been added back due to


popular demand. This enables, for example, the
Querying of BOLT info for piping components.

Design
11.6.sp3

(5518)

Resolved an Unhandled Exception (Object


reference not set to an instance of an object) caused
by an UNDO after moving an object using the
locator handles and then deleting the 3D View.

Design
11.6.sp3

HPD 27480
(5807)

Data listing of DRWG improved. Problems occurred Draft


at a DPOINTS with DTOF. This was corrected
11.6.sp3
treating DPOIs like DPPTs, so that their critical
attribute (POS) is not initialised on creation.

HPD 20209
(6772)

A combination of ATTA, Sheet break, ATTA in a


particular sequence caused a dimensioning error.

HPD 30819
(8701)

VANTAGE PDMS Version 11.6.SP5


User Bulletin

Isodraft
11.6.sp3

11-28

Product Faults and User Requests

HPD 27992
(6850)

Query attributes at a SPEC, SPCO, SELE in


Paragon no longer gives an error.

Paragon
11.6.sp3

HPD 28432

Unnecessary rectangle no longer plotted for OLET


in certain circumstances.

Isodraft
11.6.sp3

Support (trunnion) dimension on elbow no longer


shows cut length rather than distance to elbows
P0.

Isodraft
11.6.sp3

HPD 77267
(7089)

Achieved a significant reduction in number of


database pages written on a Flush with Refresh.
This takes effect only on a such a Flush, when no
changes have been made in the parent extract.

General
11.6.sp3
(also
11.5.sp1.45)

HPD 28795
(7141)

Merge Changes did not correctly update pointers


between session pages, resulting in subsequent
flushing corrupting the Database. The command
EXTRACT FLUSH RESET also led to a Product
crash. These faults have now been corrected.

Admin
11.6.sp3

HPD 28871
(7199)

The presence in sequence of additional MTO


records caused welds attached to a support ATTA
to appear incorrectly in the weld report.

Isodraft
11.6.sp3

HPD 16673
(7314)

Resolved problems with the dimensioning of a skew Isodraft


box on a pipe that is modelled in a non-orthogonal
11.6.sp3
direction.

HPD 25281
(7268)

Resolved a problem modifying ACR GROUPS.

Admin
11.6.sp3

(7413)

The Design Pipework application (Modify Pipe


form) had a fault causing the options to be lost and
an error Array element 0 does not exist. This
forced the user to close the form and reopen it. This
has been corrected.

Design
11.6.sp3

(7786)
HPD 31108

Corrected a fault causing Utilities>Send Message


for a GLOBAL project to give an error '(61,680)
F&M: Cannot access column data for gadget
!!ADMMESS.LOCN, it is not multi-column'.

Admin
11.6.sp3

HPD 29892
(8020)

Corrected Iso Dimensions and Error message when


using user defined SKEY.

Isodraft
11.6.sp3

HPD 29954
(8047)

Corrected dimensioning in certain circumstances


around ATTA.

Isodraft
11.6.sp3

(6874)
HPD 28541
(7034)

(8812)

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-29

Product Faults and User Requests

HPD 29964
(8053)
HPD 30475
(8532)

Confusing layout of the HVAC modify form


corrected.

Design
11.6.sp3

HPD 30008
(8119)

Corrected dimensioning when using SPECBREAK


BRANCH around ATTA.

Isodraft
11.6.sp3

HPD 30026
(8144)

A combination of dotted lines and hangers caused


an incorrect dimension.

Isodraft
11.6.sp3

(8154)

Corrected an error with Design Explorer


navigating to an element and selecting Query >
Attributes

Design
11.6.sp3

(8186)

While creating ADP view with limits set to


drawlist, an error illegal values for attribute
VSCA appeared and the view was not generated.

Draft
11.6.sp3

(8214)

ATTEXT command now enables the addition of


extra text to the material list for tube as well as
fittings.

Isodraft
11.6.sp3

HPD 30171
(8320)

The Cutpiece number table did not match the


cutpiece numbers on the iso for split drawings.
This was becasue the bends had no SKEY set.

Isodraft
11.6.sp3

HPD 30009
(8327)

Field Weld labels were shifted to the next weld.


and Cut piece lengths after field welds were wrong,
when the welds were followed by a Tee.

Isodraft
11.6.sp3

HPD 30200
(8334),
HPD 31094
(8796)

New pipe creation form no longer lists wrong sizes


for inch bores.

Design
11.6.sp3

HPD 30195
(8335)

Splash error no longer given when the user selects


a menu entry and drags the cursor into the main
display.

Design
11.6.sp3

HPD 30231
(8374)

PZAXIS (& other axis attributes) may now be reset


to unset.

Paragon
11.6.sp3

Corrected dimensioning on isometrics with "dime


comp on" and Tolerance Offset 2mm :

Isodraft
11.6.sp3

HPD 30387
(8508)
HPD 30048
HPD 30254
(8401)

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-30

Product Faults and User Requests

(8402)

A form handling fault meant that manipulation of


a View gadget could cause another gadget to
reappear in an inactive state. The system now
ensures that a view's form is displayed before
allowing refresh of status line label widgets.

Design,
Paragon
11.6.sp3

HPD 30094
(8434)

Corrected GUI error in setting MTO length and


Quantity of Detail Text.

Paragon
11.6.sp3

HPD 30037
(8435)

PLINEs are now drawn and the filter works


correctly.

Design
11.6.sp2.1

(8494)

Corrected a problem causing a memory error to be


reported. This was caused by some databases in an
extract tree having been compacted, while others
hadn't.

DICE
11.6.sp3

(8496)

Lug SKEYs WLR and WLC are now user


definable.

Isodraft
11.6.sp3

HPD 30320
(8515)

AutoDRAFT will now work with AutoCAD 2004,


2005, 2006.

Draft
11.6.sp3

HPD 30350
(8521)

Translucent obstruction now works with holes on.

Design
11.6.sp3

HPD 30470

Background Process Manager did not run the jobs


for certain users/passwords, for example if the
username was only one character.

Draft
11.6.sp3

(8601)

HPD 31361
(8931)
(8595)

HPD 30393
(8529)

(8557)
(8869)

It has been updated and now also copes properly


with characters with an ASCII value less than 32.
Reselecting components out of spec in the Design
Pipework application, now works correctly.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

Design
11.6.sp3

11-31

Product Faults and User Requests

HPD 30349
(8534)
(8855)

The 3D display has been corrected to show the


teeth of the section planes in the correct direction.
In the 3D view, the teeth indicate which side of the
plane the objects will be kept, and the display
changes when the user flips it.

Draft
11.6.sp3

The Planes are now shown on the 2D view at the


same time as the 3D view. In the 2D view, the
shaded area indicates where the plane itself is, and
does not change when the user switches between
'in front' and 'behind'.
HPD 30367
(8535)

PDMS no longer shuts down if Windows/Forms for


Explorer, Command Window and Drawlist are in
one set and moved together.

General
11.6.sp3

HPD 30485
(8538)

Improved display of the alert input form with long


text it no longer gets cut off.

General
11.6.sp3

(8544)
(8572)

Highlighting on ppoints (& plines) for picking, e.g.


if you use Q IDP @ when you select the item, was
not working, though there was feedback in the
prompt space for the ppoint passed over.

Design
11.6.sp3

HPD 30327
(8564)

Output in some Draft Admin forms has been


improved so that it no longer shows as an
exponential number.

Draft
11.6.sp3

HPD 30649
(8613)

SAVEWORK from the menu corrected to work for


Model Management projects with a missing default
file des-userdefinedhook.pmlmac.

Design
11.6.sp3

HPD 30074
(8615)

A floating window no longer causes PDMS to crash


on a machine with two screens.

Design
11.6.sp3

HPD 30730
(8664)

Corrected a WELD symbol error caused by the


sequence TUBE WELD, zero length BEND, TUBE.

Isodraft
11.6.sp3

HPD 30740
(8669)

Precision in Draft Admin increased.

Draft
11.6.sp3

HPD 30819
(8701)

General option added back to Query menu

Design
11.6.sp3

HPD 30019
(8702)

Bolt diameter units were incorrect in the material


list when Vessel/Equipment Trim is chosen.

Isodraft
11.6.sp3

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-32

Product Faults and User Requests

HPD 30852
(8745)
HPD 31127
(8808)

New Component Creation form no longer places a


90 degree elbow in place of a 45 deg one.

Design
11.6.sp3

HPD 30234
(8754)

Corrected errors with reference dimensions at the


mid point of a tee.

Isodraft
11.6.sp3

HPD 31124
(8787)

Corrected error in Merge Changes handling of


Table pages that caused DICE errors or a crash in
an extract hierarchy.

General
11.6.sp3

HPD 31125
(8790)

Corrected fault causing Reconfigurer to crash with


kerror 41.

General
11.6.sp3

HPD 31132
(8805)

Corrected a fault that caused a crash when


deleting a DPSE under a ZONE.

Design
11.6.sp3

HPD 30984
(8838)

Corrected a fault causing partnumbers to be


missed from the drawing they were on the
material list. This was traced to the fact that
Spooler gave new part numbers to components
across Branches, but Isodraft did not consolidate
them when outputting part numbers FROMDB.

Isodraft
11.6.sp3

HPD 31174
(8840)

Resolved a fault causing a SPLASH error message


when running a piping system isometric.

Isodraft
11.6.sp3

HPD 31076
(8842)

Can now use the GUI to modify the origin of a piece Design
of equipment when using Ppoints On, Numbers
11.6.sp3
Settings.

HPD 31187
(8844)

The Purpose field on the Create Site form now


shows the correct data.

Design
11.6.sp3

(8848)

In Annotation Modify Mode, the box can no longer


be resized to make the size smaller than the
minimum permitted view size.

Draft
11.6.sp3

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-33

Product Faults and User Requests

(8849)

Various improvements to the operation of the


Viewfinder and 3D view:

Draft
11.6.sp3

(1) The 3D view always does reflect the VIEW


direction. There is now an extra option on
viewfinder menu to 'look through' view finder
(same as on 3D view popup menu), which may help
user to orientate himself.
(2) The OK button on the modify view form now
updates the 3D view graphics.
(3) On UNDO the system now issues an alert if
UPDATE DESI required.
(4) There is a new option on the orientation menu
to reset the angle to zero.
(5) Moving the view frame with the secondary
mouse button & selecting cancel now clears the 2D
view temporary graphics.
(6) Resize hotspots are now be cleared for a new
view.
HPD 29872
(8867)

Isodraft no longer creates a slope arrow with the


wrong slope direction (where the start/end of a
tapped fitted branch was incorrectly treated as if it
is on the main pipe).

Isodraft
11.6.sp3

(8871)

The Equipment application utility to control


graphical navigation (selecting Equipment, Subequipment or Primitive) did not work at 11.6 and
has been changed so that it works better:

Design
11.6.sp3

The toolbar Navigate button is now a toggle:


On allows equipment and primitive level picking
using EDG as before
Off means that Model Editor mode is used.
The Model Editor mode button is inactive when in
any EDG mode.
HPD 30916
(8876)

Unpinned docked windows are no longer animated:


they now appear and disappear instead of sliding
back and forth.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

Design
11.6.sp3

11-34

Product Faults and User Requests

HPD 31216
(8890)

The Dimension line for the Valve was incorrectly


extended to include a connected Flange. (Flange
was

Isodraft
11.6.sp3

MTOC OFF MTOC DOTU MTOC DOTD the


flanges, gaskets and valve were all SHOP FALSE.)
AID text now has a background colour to make it
more easily visible, especially on point clouds.

Design
11.6.sp3

HPD 31252
(8897)

A long piece of pipe was incorrectly split in two in


the MATC file under certain circumstances.

Isodraft
11.6.sp3

(8909)

Flush can now handle elements in secondary lists


which no longer exist.

Design
11.6.sp3

HPD 31351
(8920)

Spool number was missing at a bypass.

Isodraft
11.6.sp3

HPD 30657
(8932)

Spool numbers greater than 99 are now handled.

Isodraft
11.6.sp3

HPD 31213
(8949)

Corrected a fault causing a 'twisted' pipe drawing


with the option FALLSKEW TWODBOX ON.

Isodraft
11.6.sp3

HPD 31405
(8952)

When showing existing pipe by setting the MTOC,


MTOH and MTOT attributes of the existing
components and/or branches to DOTD, spool
numbers are no longer shown for these items.

Isodraft
11.6.sp3

HPD 31401
(8955)

The OUTC command now displays a REAL UDA


correctly according to its settings.

Isodraft
11.6.sp3

HPD 31439
(8965)

Corrected the bend curvature appearance on the


drawing isometric. (This was the first bend in a
spool drawing, right after a flange.)

Isodraft
11.6.sp3

HPD 31448
(8974)

The Draft GUI will now output the results of


queries more accurately.

Draft
11.6.sp3

(8976)

Corrected a spatial map inconsistency error shown


by DICE after a merge. This could result in a
Dabacon error 534 in DESIGN

General
11.6.sp3

HPD 31489
(9001)

Corrected an error in composite dimensions when


insulation is set for a zero length pulled bend
which is followed immediately by a Tee in-leg.

Isodraft
11.6.sp3

(9008)

Speed improvement when adding a large XGEOM


to the Design Explorer.

Design
11.6.sp3

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-35

Product Faults and User Requests

HPD 31554
(9021)

Report template width field extended.

Design
11.6.sp3

HPD 31611
(9061)

Corrected a crash caused by a catalogue item


having more than 100 visible ppoints.

Design
11.6.sp3

HPD 31658
(9062)

Corrected a missing item number on Iso for an


instrument that should be marked correctly with
both item number and the name of the item
(because of an OUTCOM element).

Isodraft
11.6.sp3

HPD 31463
(9065)

The drawing of Venturi (PCOM with SKEY based


on SGPL) with 3 offline legs has been improved.

Isodraft
11.6.sp3

Currently, Isodraft restricts the number of tapping


points on a PCOM to 3 2 end points and 1 middle
point. If a tapping is not close to the centre, it is
pushed to the nearest end this tolerance has been
relaxed but users are advised to place the middle
tappings as close to the centre as possible.
(9073)

Performance improved - deletion of many table


entries no longer causes empty database pages.

General
11.6.sp3

(9083)

Improved SaveWork speed by reducing the


dynamic memory allocated.

General
11.6.sp3

HPD 31711
(9091)

Corrected dimensional errors on branches.

Isodraft
11.6.sp3

HPD 31743
(9092)

Corrected an error causing file write locks to be left


when a flush generated error.

General
11.6.sp3

HPD 31744
(9095)

Corrected an error causing a name clash not being


detected on Flush.

General
11.6.sp3

HPD 31687
(9097)

Corrected a Dimension problem with set-on tees


with no spool the dimension was from the HPOS
instead from the centre line of the main branch.

Isodraft
11.6.sp3

HPD 31763
(9104)

The number of welds at LUGs has been corrected.

Spooler
11.6.sp3

HPD 31859
(9131)

Corrected the replicate macro so that it does not


Admin
insert a $ at the end of a long line as a continuation 11.6.sp3
in the middle of a text string.

HPD 31901
(9161)

Corrected a crash when setting attributes to rules.

VANTAGE PDMS Version 11.6.SP5


User Bulletin

Design
11.6.sp3

11-36

Product Faults and User Requests

HPD 31902
(9164)

Corrected a crash when navigating to Draft


elements in Design.

Design
11.6.sp3

(9219)

Corrected a crash when making a relative move


(BY) using Positioning Control (Graphics option)
and picking the "marker" cone at the branch TAIL.

Design
11.6.sp3

(9236)

Corrected viewfinder operations to prevent an error Draft


message Variable!!DRA3DVIEWSECTIONS does
11.6.sp3
not exist.

HPD 32018
(9259)

Fixed error querying attributes of SCOM, or using


Show Attribute).

VANTAGE PDMS Version 11.6.SP5


User Bulletin

Paragon
11.6.sp3

11-37

Product Faults and User Requests

11.6 Faults corrected and minor enhancements

*sp4*

This lists the most important corrections in Service Pack 4, at the time of writing
(January 2007). Please note that the list is not complete; some other internally
reported issues have also been corrected.

Reference

Description

(1071)

Modifying a hanger with a locked element used to H&S


delete the other elements. The application now
verifies whether the hanger or its elements are
locked before deletion.

(1116)

Error handling improved for creation of hanger.

H&S

(1117)

Clear Aid function improved; options provided:


Remove Axes & Remove All (Axes, Lines & Text).

H&S

(1156)

Modify > Fill menu option at BRANCH level


improved.

DESIGN
Cable Trays

Improved user interface for modifying branch


specification.

DESIGN
Cable Trays

No longer gives variable not defined error


message on creation of stanchion of E type wicket
gate with no cross member.

DESIGN
H&S

(1170)
(1338)

Module

(1410)

No longer gives warning message Form


CLCLACHK too large for screen.

DESIGN

(1876)

User interface layout corrections.

ROUTER

(2158, 2275,
2309, 2579,
2606, 7594,
8583, 9137)

Various corrections and improvements to user


interface.

ADMIN

(2300)

Insulation no longer displayed in mm when using


in Imperial units.

HVAC

(2308)

Description field now accepts text in single


quotes.

ADMIN

(2768)

The user is prompted to enter a positive value for


scale-up factor for DXF/DGN output.

DRAFT

HPD 16691

Correction of various errors related to the use of

DESIGN

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-38

Product Faults and User Requests

Reference

Description

Module

(3342)

Imperial (English) units.

H&S

(3414)

The current project name is no longer shown in


the Foreign Projects section of the Include
Foreign database form.

ADMIN

(3450)

Error message is now given if a user attempts to


modify an element deleted by another user.

DESIGN

(3457)

The Filter option now works correctly on the in


the DB set selection form.

ADMIN

(3474)

Saved template file is now correctly deleted in


PDMSUSER by Utilities>Export>Delete.

DESIGN
GENERAL

(3450)

The system no longer fails to display an error


message to a user working on a Multi-write DB
with implicit claim, when attempting to modify
an element that has been deleted by another.

DESIGN

(3500)

An error is now shown when attempting to


position an object without specifying the
direction.

DESIGN
HVAC

(3505)

Duplicate name error handled when Setting


configuration for tube hanger.

DESIGN

HPD 19210
(3534)

Create > Support > Template item added to the


Create Support menu.

DESIGN
H&S

(3575)

The Filter option has been corrected.

ADMIN

(3581)

Admin Elements form operation has been


ADMIN
improved when changing the type of element. The
Filter and Sort by selector are updated and
buttons grayed out or activated as appropriate.

(3676, 9366)

User interface corrections mean that correct


Form Data is now shown when modifying a
DATA Element and that string properties can be
defined.

PARAGON

(4842)

Project>Expunge>Claimlist... in ADMIN now


shows correct display list of multiwrite
databases.

ADMIN

(5240)

The performance of picking is much improved. In


particular, the time to dimension (LDIM and
ADIM) and label (GLAB) has been speeded up.

DRAFT

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-39

Product Faults and User Requests

Reference

Description

Module

(5432)

Right click menu is now correctly displayed in


DGN General.

DRAFT

(6672)

View scale is no longer shown as a decimal on


DRAFT 3D View.

DRAFT

HPD 25077
(6705)

Flow arrows on Trunnions may now be prevented


by using the new 'OFF' setting for the 'FLOW'
attribute of BRANCH.

ISODRAFT

HPD 28322
(6842)

Corrects fatal error in Isodraw when drawing 4


PCOMs with SKEY UNIV due to lack of space
for the symbols.

ISODRAFT

HPD 28432
(6874)

Corrected Rectangle shape being shown for OLET


ISODRAFT
(Skey:WTBW),

HPD 16192
(6947)

A valve with a user defined SKEY caused


misplaced dimension line and instrument text to
be drawn outside the balloon.

ISODRAFT

HPD 18377
(6958)

Corrected dimension near skewed elbow.

ISODRAFT

HPD 28754
(7070)

Corrected support dimension.

ISODRAFT

HPD 28727
(7073)

Corrected SPLASH error when drawing certain


supports.

ISODRAFT

(7076)

Settings > Defaults > Main option is now more


robust.

H&S

(7087)

Modify > Hanger > Attributes prompts the user


to select the hanger. If the user then presses the
<Esc> key the Position form is now [properly
cleared.

H&S

HPD 26368
(7124)

Corrected a fault causing welds to be shown as


Shop for Site caps.

ISODRAFT

(7523)

Project field on Entry form is now checked for


valid input.

ADMIN

(7554)

Main menu option Display > Drawlist form could


cause Syntax Errors. These have been corrected.

SPOOLER

(7562)

Invalid section splitting no longer causes PML


Error message.

Design
Structural

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-40

Product Faults and User Requests

Reference

Description

Module

(7593)

Up or Down arrow no longer pops up error in


Create Date Stamp

ADMIN

(7778)

Radio gadget callback no longer repeated after


alert in certain circumstances.

GENERAL

(7861)

Several improvements to layout and usability of


the user interface.

DRAFT

(7894)

System will no longer crash when attempting to


rotate a selection that has been deleted!

DESIGN

HPD 29540
(7907)

Pipe Bore in the Title-block is no longer shown in


feet and inches for a Pipe of bore 24" and above.

ISODRAFT

(8182)

Error cannot create SLAB at this level no


longer given while creating SLAB.

DRAFT

MDS Trunnion offset is shown wrongly on Iso.

ISODRAFT

(8243)

Remove from View option in 3D view no longer


gives error Variable IDlist does not exist.

DRAFT

HPD 30141
(8259)

Corrected problems with z direction for


instrument connections on sloped lines.

ISODRAFT

(8582)

The Utilities definition form now checks the


description better.

DESIGN
HVAC

(8607)

User Interface improvements.

DESIGN
H&S

(8608, 9390,
9406)

User Interface improvements.

ROUTER

(8870)

Quick Pipe Routing Insulated pipe handled


better.

DESIGN

(8889)

Error message now displayed correctly when


dragging from Explorer to 3D view.

DESIGN

HPD 31258
(8956)

ISODRAFT no longer gives minor discrepancies


in dimensions for certain options.

ISODRAFT

HPD 31439
(8965)

Bend curvature is no longer in the wrong


direction on the isometric.

ISODRAFT

HPD 31509
(8996)
HPD 31508

Dragging a FRMW into the 3D view will no


longer add the owning STRU to the 3D or 2D
draw list.

DRAFT

HPD 30020
(8203)

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-41

Product Faults and User Requests

Reference

Description

Module

(9018)

Longer database names (up to 93 characters) can


now be used in the CNAME operation; the
system will output an appropriate error message
when attempting to use a longer name.

ADMIN

HPD 31551
(9022)
(10149)

It is now possible to run cursor functions


(including VAR !pick) from a blocking form in
certain cases. This is to resolve an issue with a
PML form that worked at PDMS 11.5 but used to
hang the system at 11.6.
This is a blocking form that requests a VAR !p
PICK sub-mode on the OK button. At PDMS
11.6.sp3, when the user clicks the OK button, the
form stays displayed; the user is unable to make
a pick, as the blocking form is preventing it. The
form is now removed and the user can perform
the pick.
Please note that blocking forms can lead to poor
(demand driven) user interfaces. It is
recommended that they be used only to force the
user to provide data for which there are no
defaults. An alternative might be to have a nonblocking form managing the task; this would
allow the display of a blocking form to acquire
critical data and would also control access to
graphical picking.

DESIGN
11.6.sp4

HPD 31676
(9070)

Corrected an error in the number of Spools.

ISODRAFT

HPD 31780
(9106)

Corrected SPLASH error in Isodraft Mode.

DESIGN

HPD 31808
(9135)

Deletion of a DB no longer rearranges the sort


order.

ADMIN

HPD 32588
(9140, 9445)

No longer gives erroneous Dabacon error 516


after flush error.

(9180)

No longer gives unwanted message Can't convert DRAFT


string to Db Ref from Change Representation
Rules form.

HPD 32010

Performance improvements for graphical picking;


no longer highlights incorrect item. Explorer

(8997)

VANTAGE PDMS Version 11.6.SP5


User Bulletin

ALL

DESIGN

11-42

Product Faults and User Requests

Reference

Description

(9223)

performance improvements.

HPD 32067
(9252)

Weld is no longer missing on iso when a reference


dimension is attached to the welded elbow. (Weld
table was already OK.)

ISODRAFT

HPD 32077
(9257)

Increased limits that caused Error in SPLASH


routine HGETS1 Area: Handling when drawing
very complex isometric.

ISODRAFT

HPD 32172
(9306)

Corrected a fault causing Splash error 9 on a


particular Spool Iso with OLETs.

ISODRAFT

HPD 32190
(9313)

Corrected a crash when a reducing flange was


followed by lap joint.

ISODRAFT

HPD 32211
(9324)

Corrected a warning about gadget placement in


the PML Browser form.

GENERAL

HPD 32178
(9327)

Corrected an error in overall dimensions in an


almost vertical line with the use of the zero
length skew option.

ISODRAFT

(9343)

Now navigates correctly to the element in the


navigation bar of the names form when using
main menu Modify > View > Local Rules.

DRAFT

(9345)

Corrections to several User Interface layout


faults, giving improved usability.

DRAFT

HPD 32286
(9353)

Corrected a fault causing tube to be shown


between mating flanges.

(9357)

The Modify tool bar button is no longer greyed


DESIGN
out if the escape key is pressed to exit EDG mode.

HPD 32362
(9369)

Textpane text limit increased by handling in a


different way.

DESIGN

HPD 32322
(9371)

Part numbers on iso no longer duplicated.

SPOOLER

(9376)

Supplied pdms.bat & evars.bat files revised to


remove references to FD versions of projects.

General

HPD 31250
(9379)

Calculation of skew angles on Isometric drawing


now matches better with the 3D view.

ISODRAFT

HPD 32365
(9393)

Branch is now plotted in the correct direction


when zero long components are at the pipe head.

ISODRAFT

VANTAGE PDMS Version 11.6.SP5


User Bulletin

Module

ISODRAFT

11-43

Product Faults and User Requests

Reference

Description

Module

(9394)

An element is created, stored using SAVEWORK


and then deleted, followed a QUIT operation
This used to leave the element in a state where
'Delete' and 'Rename' are greyed out on the popup menu in the Explorer, but is now corrected.

DESIGN

HPD 32476
(9408)
(9419)

A fault causing an error for a large name table (4


levels) when deleting pages.
Correction also made to table page splitting.

DABACON

HPD 32482
(9412)

Reference dimension no longer shown twice.

ISODRAFT

(9417)

Model manager menu not shown under Design


Utilities.

DESIGN

HPD 32514
(9420)

No longer crashes for certain combinations of


flanges & lap joints.

ISODRAFT

HPD 32603
(9451)

<space> can now be used instead of mouse click


for current focus position.

DESIGN

(9464)

User interface correction to prevent syntax error


while creating Working Extracts.

(9470)

Automatic Continuous Clash Detection


(AUTOCLASH) was failing to report clashes after
encountering an error: this has now been
corrected. This could occur, for example, when
checking a badly routed pipe. On Demand Clash
Detection was not affected.

ADMIN

DESIGN

(9494)

Extract Control no longer gives PML Error when


CE is World.

DESIGN

HPD 32449
(9510)

Iso legibility improved for certain configuration


so that dimension and text are not overlaid.

ISODRAFT

HPD 32749
(9512)

Straight line no longer broken into segments with


ISODRAFT
different slopes.

HPD 32763
(9521)

Corrected missing weld numbers on spool iso.

HPD 32832
(9548)

User interface corrected to remove message about ADMIN


Variable !!CHECKNOUPD on use of Update
Event Form.

HPD 32927

Corrected dimension error caused by combination

VANTAGE PDMS Version 11.6.SP5


User Bulletin

ISODRAFT

ISODRAFT

11-44

Product Faults and User Requests

Reference

Description

(9567)

of Flow Arrow, Composite dimension & Support.

HPD 32928
(9568)

Pipe Cut length number no longer wrongly


displayed along a pipe when material output is
switched off.

HPD 32899
(9584)

Part numbers for Reducers now shown and the


material list collected correctly.

HPD 32949,
HPD 33088,
HPD 33258
(9591, 9610,
9740)

New facility added to show weights and totals on


isometrics. Please see section 4.7.

ISODRAFT

HPD 32975
(9593)

Corrected a fault causing the branch order


around ATTAs to be reordered when moving
components with the model editor.

DESIGN

HPD 31504
(9597)

Dimension of support to field weld of flange now


ISODRAFT
shown when flange attribute MTOC set to DOTU.

HPD 33068
(9607)

IWELD for LUG is no longer missing in spool


drawing.

SPOOLER

HPD 33093
(9611)

Corrected OLET/PIPE misalignment on spool iso.

ISODRAFT

HPD 33139
(9623)

Unwanted skew no longer appears at a particular


bend configuration.

ISODRAFT

HPD 33170
(9639)

Primitives with translucent obstruction now


shown in correct position.

DESIGN

HPD 33312
(9652)

Performance improved for modification of SDTE


with a large number of detail texts.

PARAGON

HPD 33195
(9665)

Errors with multi-write databases corrected


these were sometimes caused by deletion of Draft
objects and UNDO.

DRAFT

HPD 33344
(9676)

Corrected a crash caused by use of DACs when


using MDS.

DESIGN
MDS

(9695)

Corrected Array bounds error in VLDMRC - IA(0)

ISODRAW

HPD 33657
(9772)

Corrected the coordinates on the iso around


particular configuration of ELBO used by MDS.

ISODRAFT

HPD 33804

Can now successfully use EDG to pick D-Points

GENERAL

VANTAGE PDMS Version 11.6.SP5


User Bulletin

Module

ISODRAFT
ISODRAFT

11-45

Product Faults and User Requests

Reference

Description

(9777)

under XGEOM

(9781)

Explorer no longer fails to load if there are no


members.

Module
SPOOLER

(9787)

Database error 41 no longer occurs when


hovering over the view frame in the 3D view.

DRAFT

(9902)

Can now re-enter H&S after using File>Save


option from Application Defaults form.

DESIGN
H&S

11.6.1 Corrections to Global 2.4.SP1 (issued with PDMS 11.6.sp4)


Reference

Description

Module

(0940)

Corrected a crash when using REPLICATE at a


satellite

Global

HPD 33318
(9328, 9926)

Corrected an error while creating update event at


satellite location.

Global

(9391)

Copy command text from Transaction messages


form

Global

(9452)

Fixes to Global 2.4 file-copy functionality


(Suppress spurious errors)

Global

(9555)

Restore lost Remote Session methods (Access to


these is fairly obscure, via PML Location objects)

Global

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-46

Product Faults and User Requests

11.7 Faults corrected and minor enhancements

*sp5*

This lists the most important corrections in Service Pack 5, at the time of writing
(October 2008). Please note that the list is not complete; some other internally
reported issues have also been corrected. The list includes points that affect only
Global projects.
Corrections made at PDMS 11.6.SP5:
Incident
number

Defect
number

Description

Module

HPD 37648

P-10276
(11709)

Corrected output of Simplified Chinese characters in


MATL (material list) file with mixed English/Chinese text.
This file now matches the (correct) output of the material
information on the Isometric.
However, the MATC file still outputs a coded description.

Isodraft

HPD 27771

P-9186
(6673)

Correct symbol now shown on reducer continuation

Isodraft

HPD 35622

P-10271
(11695)

SQL-Direct did not work at PDMS11.6.SP3 or 4.

SQL-Direct

HPD 36807

P-10230
(11632)

Background Process Manager was failing with some


passwords

Draft BPM

HPD 37174

P-10260
(11678)

Now correctly selects component from alternate spec,


rather the branch spec.

Design

P-7716

Improvements to the handling of Asian characters to


prevent spurious messages: error (2,792) Cannot assign to
attribute.

Design

P-8109

Improvements to the handling of Asian characters to


prevent spurious messages: (2,109) Undefined name

Design

HPD 37796

P-10368

Japanese Shift-JIS DXF file no longer has errors in certain


characters codes. Please note that updated AutoCAD font
files should also be used these are available separately.

Draft

HPD 37890

P-10291
(11729)

Corrections have been made to Reconfigurer to prevent


certain cases of database corruption

Admin

HPD 36107

P-10181
(11540)

Changing Lvisibility from true to false, when you have


multiple views on a sheet with all the view frames are
turned on, no longer causes the view to disappear

Draft

HPD 38119

P-10451

Bad Skewbox dimensioning

Isodraft

HPD 38200

P-10452

Material control files in error

Isodraft

HPD 38120

P-10468

Spurious length of pipe and bad Skewbox triangle

Isodraft

HPD 32183

P-10607

No status flag error

Isodraft

HPD 34955

P-10608

Wrong dimension and wrong representation on isometric.

Isodraft

HPD 35321

P-10609

Check valve dimension is wrong on isometric

Isodraft

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-47

Product Faults and User Requests

Incident
number

Defect
number

Description

Module

HPD 35905

P-10610

Duplicate part numbers for tubi connected to seton

Isodraft

HPD 36110

P-10611

Weld Numbering Error

Isodraft

HPD 36484

P-10620

Wrong dimensions on pipe legs with olets

Isodraft

HPD 36585

P-10621

Problem using weld for small slopes an pipes

Isodraft

HPD 36969

P-10622

Isodraft produces an FATAL ERROR while processing

Isodraft

HPD 34236

P-10623

Missing Bends in Part List

Isodraft

HPD 37298

P-10624

Connections to 6-way components do not always show


correctly

Isodraft

HPD 37347

P-10625

Spooler deletes the WLDGRP or JNTGRP

Isodraft

HPD 37612

P-10626

Iso not up to date

Isodraft

HPD 37060

P-10627

IWELD not shown on SPLDRG

Isodraft

HPD 32183

P-10607

No status flag error

Isodraft

HDP 37836

P-10289

Partno 2 is shown in Part List but not on the Iso

Isodraft

HPD 37171

P-10301

A fatal error has occurred in ISODRAW

Isodraft

HPD 38347

P-10333

dimension line of overall length points to wrong p

Isodraft

HPD 34769

P-10085

Incorrect bore value shown on Iso

Isodraft

HPD 38668

P-11708

Tube numbering problem for Pulled Bends with no leave


tube

Spooler

P-11709

IWELD created when COCO not defined

Spooler

HPD 38179

P-11743

Bolt part numbers incorrectly consolidated by Gateway

Isodraft

HPD 38638

P-11820

Bolting problems with Isodraft equipment detailing

Isodraft

HPD 38849

P-11920

We have a problem with numbering if after the spool


break are (support) ATTAs

Spooler

11.7.1 Corrections consolidated from previous fix releases:


Incident
number

Defect
number

Description

Fix
Version

DFN03777

Centreline lengths calculated incorrectly for Imperial


lengths

12

DFN07469

Error maintaining branch count when pipe contains


pslists

12

HPD 31255

DFN08906

The dimension to a welded attachment is incorrect

12

HPD 32183

DFN09310

No status flag error

12

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-48

Product Faults and User Requests

DFN09492

fix for preventing the router menu showing if router


appware is not installed.

12

HPD 34955

DFN10449

Wrong dimension and wrong representation on isometric

12

HPD 35321

DFN10667

Check valve dimension is wrong

12

HPD 35905

DFN11458

Create IWELD for Seton TEEs

12

HPD 36110

DFN11550

Weld Numbering Error.

12

HPD 36484

DFN11592

Wrong dimensions on pipe legs with olets

12

HPD 36490

DFN11597

Same dimension appears twice.

12

HPD 36585

DFN11611

Problem using welds for small slopes on pipes

12

HPD 36613

DFN11615

Issue with dimensions on isometric

12

HPD 36969

DFN11651

Isodraft produces an FATAL ERROR while processing

12

HPD 37002

DFN11662

Number FTUB with SKEY of TUBE

12

HPD 34236

DFN11667

Number Pipe with different Specs distinctly

12

HPD 36903

DFN11673

Reposition at component after FROMSPCOM command

12

HPD 36538

DFN11683

Error reporting WBORE of an IWELD

12

HPD 37298

DFN11693

Connections to 6-way components do not always show


correctly

12

HPD 37347

DFN11702

Only remove or copy the Weld or Joint group being


created

12

HPD 37512

DFN11705

Incorrectly positioned continuation text

12

HPD 37612

DFN11710

SPOOL_ERROR_INTERNAL when Gasket first element


of Spool drawing

12

HPD 37060

DFN11725

Do not create Welds at ATTAs even if SPKBRK is True

12

HPD 37836

DFN11727

Treat MTOC values of DOTD and DOTU as OFF

12

HPD 35876

DFN11434

Incorrect CofG when SCTN on a Template joint is


queried using command line

11

P-4417

DRAFT entry time too long (11.6)

P-4419

Plines & memberlines sometimes truncated rather than


drawn to node point (11.6)

DFN11403

Fix bug in db5_flush which was leaving stacks when


error 573 was generated

DFN11391

Fix bug in db5_flush which was leaving stacks when


error 573 was generated

P-4372

PipeCheckAddin can cause delays exiting design


(Additional performance enhancement)

HPD 36348

DFN11587

SCTN with profile of cone crashes PDMS

DFN9293

Inter-DB macros for deleted DB

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-49

Product Faults and User Requests

DFN11640

Extract Flush Reset crashes remote daemon

DFN11635

UPDATE command does nothing in certain network


configurations

DFN2128

Secondary merge causes update failures due to


prevention of reverse propagation

P-4315

Prevent potential problem with endpoints in file-copy


after ADMNEW check

P-4319

Undefined variables affecting REMOTE MERGE for


Transaction db

P-4316

REMOTE MERGE will stall not fail if error creating


operations

P-4408

Undefined variable caused SYNCHR ALL error

DFN11122

ADMIN crash in Q REMOTE

P-4321

SORTALLOCATE wrong in RELEASE version

DUN642

PML encryption

DFN11434

SCTN CofG error on Template joints.

DFN9713

Volume calculation on structures with TMPL. 09/01/08

HPD 28734

DFN07931

Control whether dimension value appears in/above


dimension line

HPD 33734

DFN09793

Insertion of missing horizontal lines in some tables

HPD 36076

DFN11541

Set Search Within constraint

HPD 36069

DFN11549

Fixed Length Tube Weights

HPD 36563

DFN11604

Eccentric reducer symbol at sheet break error

HPD 36284

DFN11613

Dimensions Composite

HPD 36701

DFN11625

Last ATTA co-incident with WELD

HPD 36891

DFN11643

error (61,567) F&M: Cannot find required field


!!SPLASBUILT in list/menu

HPD 36884

DFN11650

Incorrect Continuation Comment when Field Weld not


included in Spool Drawing

DUN0747

SKEY enhancements

DUN0757

Improved Continuation Sheet Functionality

DFN8502

Unhandled Dab538 in DICE

HPD 33482

DFN10456

Cannot dimension ppoint of template

HPD 35192

DFN10625

run error and crash when using add to drawlist con

HPD 34452

DFN10260

Error in SPLASH routine

HPD 34993

DFN10486

Separate Tube Weight Conversion Factor

HPD 35201

DFN10757

Weights are too close to column border

HPD 35848

DFN11366

ERROR in SPLASH routine

HPD 35905

DFN11458

Part Numbers distinct across Branches

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-50

Product Faults and User Requests

HPD 36046

DFN11528

Wrong display of tracing (visible when turned off)

HPD 36076

DFN11541

Set Search Within constraint

HPD 36069

DFN11549

Fixed Length Tube Weights

HPD 36362

DFN11578

Incorrect Continuation Comment when Field Weld added

HPD 36278

DFN11581

Missing Weights for MTOREF Items

HPD 36497

DFN11596

atta showing as bend

DFN11610

The fix is to make the Model Management menu entry


available in Spooler.

HPD 36076

DFN11541

Unhandled Exception error when using spooler > Cope


better with Spools that contain more than 500 item

HPD 35015

DFN10459

Valve dimension is wrong.

HPD 35201

DFN10757

Weights are too close to column border

HPD 35736

DFN11130

Problem with Elbow angle when the first digit after the
decimal is a 0

HPD 26805

DFN7121

Split atta causes wrong dimensions

DFN10905

Zillions of lines of "DRAWING INSIDE TITLE BLOCK"

HPD 35079

DFN10619

PDMS Model Editor Error when I use at ATTA.

HPD 35111

DFN10533

Specon destroys CATA DB. Problem with long member


list.

DFN10622

Data changed on UDA not saved with SAVEWORK (if


last dynamic attribute on already created element)

HPD 34969

DFN10752

PDMS116SP4 takes 5 minutes or more to exit (and


Splash crash fix)

DFN9621

Fix for Splash crashes on module switch

HPD 35408

DFN10470

Re-introduce bottom scroll bar on forms. Modification to


discourage users from killing the PDMS console window.

HPD 35604

DFN10996

Clashes not being reported when either CLEARANCE or


TOUCH GAP values are non-zero.

HPD 35230

DFN11277

Modification to discourage users from killing the PDMS


console window.

HPD 32322

DFN9371

On the right tee you see part number 3 and part number
6 for the tee

HPD 33981

DFN9958

Wrong dimension 1453 on isometric plot

HPD 33984

DFN9975

Continuation notes are wrongly positioned on olets

HPD 34169

DFN10131

Weld number is shown in middle of pipe where there


isn't any weld

HPD 34219

DFN10151

Overall dimension is missing on isometric plot

HPD 34927

DFN10422

Overall dimension on isometric is wrong

VANTAGE PDMS Version 11.6.SP5


User Bulletin

11-51

Product Faults and User Requests

HPD 34668

DFN10329

Pipe and Cable Trays Not Clashing Correctly

HPD 33873

DFN10442

PDMS crashes on 0mm long SCTN

HPD 34833

DFN10376

change des.dll to delayload udnet.dll and sgl5net.

HPD 34554

DFN10303

Bolting query causes crash in Design after entering &


exiting from ISODRAFTMODE

11.7.2 Corrections to Global 2.5 (issued with PDMS 11.6.SP5)


Incident
number

Defect
number

Description

HPD 37152

P-10454

TRANSFER doesnt copy GLOBAL db

Global

HPD 37069

P-10455

TRANSFER and Inter-db macros

Global

P-10456

TRANSFER corrupts System db

Global

P-10457

TRANSFER TO should remove HUB macros from satellite


Transfer folder

Global

P-10458

TRANSFER FROM apparently copying dbs from local


folder, not Transfer folder

Global

P-10459

TRANSFER FROM leaves ADMIN user in Transfer Global


db, not that for local Project

Global

P-10460

TRANSFER FROM may corrupt another satellite system


db at offline satellite

Global

P-11455

TRANSFER FROM keeps re-importing macro for deleted


db

Global

P-11309

Misc db not updated correctly

Global

P-10667

TRANSFER needs FORCE PROPG option

Global

P-11475

REPLICATE SYSTEM STANDALONE problem with


/*GRO

Global

P-11524

BUCKET renamed REFBLOCKS

Global

P-11525

REMOTE MERGE synonym GLOBAL MERGE

Global

P-11526

Copy Overwrite reworded

Global

P-6896

Allocate - handle deleted location

Global

HPD 38385

P-11575

CHANGE ACCESS crash (Deleted user)

Global

HPD 33573

P-11576

Reverse Propagation after Generate

Global

P-10515

Resetting project to Offline

Global

P-9274

Replicate System Satellite errors

Global

P-11527

Copy from Foreign loses Picture-file

Global

P-10666

GLBADMIN test crash (GENERATE LOC)

Global

P-10665

GENERATE - Initialise Merge timer to unset

Global

P-11522

Transaction messages - width of refs for Save-to-file

Global

HPD 26298

VANTAGE PDMS Version 11.6.SP5