For highest demands. Short and practical.

VERSIONS

APPROVALS

zinc-plated steel
stainless steel

BUILDING MATERIALS
Approved for:
Concrete C20/25 to C50/60,
cracked
Concrete C20/25 to C50/60, noncracked
Also suitable for:
Concrete C12/15
Natural stone with dense structure

ADVANTAGES

APPLICATIONS

FUNCTIONING

The characteristics of the FAZ ll K


considerably reduce the amount of
drilling and hammer blows required
when installing the bolt anchor, thus
reducing the force needing to be
applied and the installation time.
The tried and tested expansion clip
allows for a high load-bearing
capacity, even in the case of reduced
anchorage depths.
With the FAZ II 10 K (nominal drill
hole diameter 10 mm), the tensile
loads are unchanged when
compared with standard anchorage
depths, thus achieving the maximum
performance.

The FAZ II K is suitable for prepositioned and push-through


installation.
When the installation torque is
applied, the cone bolt is pulled into
the expansion clip and expands it
against the drill hole wall.
The anchor is set in line with the
approval once the preset installation
torque is achieved.

http://www.fischer.de/en/ - 09/11/2014

Steel constructions
Guard rails
Consoles
Ladders
Cable trays
Gates
Faades

High performance steel anchors

Bolt anchor FAZ II K

min
2)

Kleinster mglicher Achs- bzw. Randabstand bei gleichzeitiger Reduzierung der zulssigen Last bei
Mindestbauteildicke (hmin 2 x hef). Die Kombination von minimalem Rand- und Achsabstand ist
nicht mglich. Einer der beiden minimalen Werte ist gem Zulassung zu erhhen.

ef

Bedingungen reduziert werden.

LOADS
TECHNICAL DATA
Bolt anchor FAZ II
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 05/0069 has to be considered.
Type

Cracked concrete
minimum maximum minimum
torque permissible permissible
min.
eective eective
member
moment tensile load shear load spacing
anchorage anchorage thickness5)
Bolt anchor FAZ II K
depth
depth
hef,min
hef,max
hmin
Tinst
Nperm3)
Vperm3)
smin2)
[mm]

FAZ II 8
FAZ II 10
FAZ II 12
FAZ II 16
FAZ II 20
FAZ II 24
1)

2)

Non-cracked concrete
min.
permissible permissible
min.
edge
tensile load shear load spacing
distance

min.
edge
distance

cmin2)

Nperm3)

Vperm3)

smin2)

cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

45

100
80
120
100
140
140
170
200
250

20,0
45,0
45,0
60,0
60,0
110,0
110,0
200,0
270,0

2,4
4,3
4,3
6,1
7,6
9,0
13,4
17,1
24,0

6,9
8,7
11,4
13,9
16,9
20,7
31,4
40,0
49,1

35
40
40
45
45
60
60
95
100

40
45
45
55
55
65
65
85
100

4,3
6,1
7,6
8,5
11,9
12,6
18,8
24,0
33,6

6,9
11,4
11,4
16,9
16,9
29,0
31,4
40,0
49,1

40
40
40
50
50
60
60
95
100

40
45
45
55
55
65
65
95
135

40
60
50
70
65
85
100
125

The partial safety factors for material resistance as regulated in the approval as well as a partial
safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g. an
anchor with a spacing s 3 x h ef and an edge distance c 1,5 x h ef. Accurate data see approval.
Minimum possible axial spacings resp. edge distance while reducing the permissible load for the
minimum member thickness (hmin 2 x hef). The combination of the given min. spacing and min.
edge distance is not possible. One of them has to be increased according approval.

http://www.fischer.de/en/ - 09/11/2014

3)

4)
5)

For combination of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval.
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
According approval the minimum member thickness (h min 2 x hef) can be reduced under specific
conditions.

High performance steel anchors

Bolt anchor FAZ II K

min

ef

nicht mglich. Einer der beiden minimalen Werte ist gem Zulassung zu erhhen.

LOADS
Bolt anchor FAZ II A4
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 05/0069 has to be considered.
Type

minimum maximum minimum


eective eective
member
anchorage anchorage thickness5)
depth
depth
hef,max
hmin
hef,min
[mm]

FAZ II 8 A4
FAZ II 10 A4
FAZ II 12 A4
FAZ II 16 A4
FAZ II 20 A4
FAZ II 24 A4
1)

2)

torque
moment

gerissener Beton
permissible permissible
min.
tensile load shear load spacing

ungerissener Beton
min.
permissible permissible
min.
edge
tensile load shear load spacing
distance

min.
edge
distance

Tinst

Nperm3)

Vperm3)

smin2)

cmin2)

Nperm3)

Vperm3)

smin2)

cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

45

100
80
120
100
140
140
170
200
250

20,0
45,0
45,0
60,0
60,0
110,0
110,0
200,0
270,0

2,4
4,3
4,3
6,1
7,6
9,0
13,4
17,1
24,0

6,9
8,7
11,4
13,9
16,9
20,7
31,4
40,0
49,1

35
40
40
45
45
60
60
95
100

40
45
45
55
55
65
65
85
100

4,3
6,1
7,6
8,5
11,9
12,6
18,8
24,0
33,6

6,9
11,4
11,4
16,9
16,9
29,0
31,4
40,0
49,1

40
40
40
50
50
60
60
95
100

40
45
45
55
55
65
65
95
135

40
60
50
70
65
85
100
125

The partial safety factors for material resistance as regulated in the approval as well as a
partial safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g.
an anchor with a spacing s 3 x hef and an edge distance c 1,5 x hef. Accurate data see
approval.
Minimum possible axial spacings resp. edge distance while reducing the permissible load for the
minimum member thickness (hmin 2 x hef). The combination of the given min. spacing and min.
edge distance is not possible. One of them has to be increased according approval.

http://www.fischer.de/en/ - 09/11/2014

3)

4)
5)

For combination of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval.
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
According approval the minimum member thickness (hmin 2 x hef) can be reduced under specific
conditions.

High performance steel anchors

Bolt anchor FAZ II K

4)
5)

Bolt anchor FAZ II K


2)

Bei hheren Betonfestigkeiten bis C50/60 sind hhere zulssige Lasten mglich.
Die Mindestbauteildicke (hmin 2 x hef) kann gem Zulassungsbescheid unter bestimmten
Bedingungen reduziert werden.

LOADS
Bolt anchor FAZ II C
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 05/0069 has to be considered.
Type

minimum maximum minimum


eective eective
member
anchorage anchorage thickness5)
depth
depth
hef,max
hmin
hef,min
[mm]

FAZ II 8 C
FAZ II 10 C
FAZ II 12 C
FAZ II 16 C
FAZ II 20 C
FAZ II 24 C
1)

2)

[mm]

45
40
60
50
70
65
85
100
125

torque
moment

Cracked concrete
permissible permissible
min.
tensile load shear load spacing

Non-cracked concrete
min.
permissible permissible
min.
edge tensile load shear load spacing
distance

min.
edge
distance

Tinst

Nperm3)

Vperm3)

smin2)

cmin2)

Nperm3)

Vperm3)

smin2)

cmin2)

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

100
80
120
100
140
140
170
200
250

20,0
45,0
45,0
60,0
60,0
110,0
110,0
200,0
270,0

2,4
4,3
4,3
6,1
7,6
9,0
13,4
17,1
24,0

6,9
8,7
11,4
13,9
16,9
20,7
31,4
40,0
49,1

35
40
40
45
45
60
60
95
100

40
45
45
55
55
65
65
85
100

4,3
6,1
7,6
8,5
11,9
12,6
18,8
24,0
33,6

6,9
11,4
11,4
16,9
16,9
29,0
31,4
40,0
49,1

40
40
40
50
50
60
60
95
100

40
45
45
55
55
65
65
95
135

The partial safety factors for material resistance as regulated in the approval as well as a
partial safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g.
an anchor with a spacing s 3 x hef and an edge distance c 1,5 x hef. Accurate data see
approval.
Minimum possible axial spacings resp. edge distance while reducing the permissible load for the
minimum member thickness (hmin 2 x hef). The combination of the given min. spacing and min.
edge distance is not possible. One of them has to be increased according approval.

http://www.fischer.de/en/ - 09/11/2014

3)

4)
5)

For combination of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval.
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
According approval the minimum member thickness (hmin 2 x hef) can be reduced under specific
conditions.

High performance steel anchors

Dbel mit einem Achsabstand s 3 x hef und einem Randabstand c 1,5 x hef. Exakte Daten
siehe Zulassungsbescheid.
Kleinster mglicher Achs- bzw. Randabstand bei gleichzeitiger Reduzierung der zulssigen Last bei
Mindestbauteildicke (hmin 2 x hef). Die Kombination von minimalem Rand- und Achsabstand ist
nicht mglich. Einer der beiden minimalen Werte ist gem Zulassung zu erhhen.

Mindestbauteildicke (hmin 2 x hef). Die Kombination von minimalem Rand- und Achsabstand ist
nicht mglich. Einer der beiden minimalen Werte ist gem Zulassung zu erhhen.

LOADS
Bolt anchor FAZ II GS
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 05/0069 has to be considered.
Type

minimum maximum minimum


eective eective
member
anchorage anchorage thickness5)
depth
depth
hef,max
hmin
hef,min
[mm]

FAZ II 8 GS
FAZ II 10 GS
FAZ II 12 GS
FAZ II 16 GS
1)

2)

torque
moment

Cracked concrete
permissible permissible
min.
tensile load shear load spacing

Non-cracked concrete
min.
permissible permissible
min.
edge
tensile load shear load spacing
distance

min.
edge
distance

Tinst

Nperm3)

Vperm3)

smin2)

cmin2)

Nperm3)

Vperm3)

smin2)

cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

45

100
80
120
100
140
140
170

20,0
45,0
45,0
60,0
60,0
110,0
110,0

2,4
4,3
4,3
6,1
7,6
9,0
13,4

6,9
8,7
11,4
13,9
16,9
20,7
31,4

35
40
40
45
45
60
60

40
45
45
55
55
65
65

4,3
6,1
7,6
8,5
11,9
12,6
18,8

6,9
11,4
11,4
16,9
16,9
29,0
31,4

40
40
40
50
50
60
60

40
45
45
55
55
65
65

40
60
50
70
65
85

The partial safety factors for material resistance as regulated in the approval as well as a
partial safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g.
an anchor with a spacing s 3 x hef and an edge distance c 1,5 x hef. Accurate data see
approval.
Minimum possible axial spacings resp. edge distance while reducing the permissible load for the
minimum member thickness (hmin 2 x hef). The combination of the given min. spacing and min.
edge distance is not possible. One of them has to be increased according approval.

http://www.fischer.de/en/ - 09/11/2014

3)

4)
5)

For combination of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval.
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
According approval the minimum member thickness (hmin 2 x hef) can be reduced under specific
conditions.

High performance steel anchors

Bolt anchor FAZ II K

Bedingungen reduziert werden.

Kleinster mglicher Achs- bzw. Randabstand bei gleichzeitiger Reduzierung der zulssigen Last bei
Mindestbauteildicke (hmin 2 x hef). Die Kombination von minimalem Rand- und Achsabstand ist
nicht mglich. Einer der beiden minimalen Werte ist gem Zulassung zu erhhen.

LOADS
Bolt anchor FAZ II GS A4
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 05/0069 has to be considered.
Type

minimum maximum minimum


eective eective
member
anchorage anchorage thickness5)
depth
depth
hef,max
hmin
hef,min
[mm]

FAZ II 8 GS A4
FAZ II 10 GS A4
FAZ II 12 GS A4
FAZ II 16 GS A4
1)

2)

torque
moment

Cracked concrete
permissible permissible
min.
tensile load shear load spacing

Non-cracked concrete
min.
permissible permissible
min.
edge
tensile load shear load spacing
distance

min.
edge
distance

Tinst

Nperm3)

Vperm3)

smin2)

cmin2)

Nperm3)

Vperm3)

smin2)

cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

45

100
80
120
100
140
140
170

20,0
45,0
45,0
60,0
60,0
110,0
110,0

2,4
4,3
4,3
6,1
7,6
9,0
13,4

6,9
8,7
11,4
13,9
16,9
20,7
31,4

35
40
40
45
45
60
60

40
45
45
55
55
65
65

4,3
6,1
7,6
8,5
11,9
12,6
18,8

6,9
11,4
11,4
16,9
16,9
29,0
31,4

40
40
40
50
50
60
60

40
45
45
55
55
65
65

40
60
50
70
65
85

The partial safety factors for material resistance as regulated in the approval as well as a
partial safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g.
an anchor with a spacing s 3 x hef and an edge distance c 1,5 x hef. Accurate data see
approval.
Minimum possible axial spacings resp. edge distance while reducing the permissible load for the
minimum member thickness (hmin 2 x hef). The combination of the given min. spacing and min.
edge distance is not possible. One of them has to be increased according approval.

http://www.fischer.de/en/ - 09/11/2014

3)

4)
5)

For combination of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval.
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
According approval the minimum member thickness (hmin 2 x hef) can be reduced under specific
conditions.