Você está na página 1de 13

IES LM-79-08

MEASUREMENT AND TEST REPORT


For

ATG Electronics Corp


9020 Rancho Park Court Rancho Cucamonga, CA 91730

Test Model: HBCC20

Report Type:

Electrical and Photometric tests including: Luminous Flux,


Color, Luminous Intensity Distribution, THD, Off-state
Power

Test Engineer:

Daniel Duan

Report Number: RSZ131022510-10


Test Date:

2014-01-07

Report Date:

2014-01-07

Reviewed By:

Jeanne Han/Safety Manager

Prepared By:

Bay Area Compliance Laboratories Corp. (Shenzhen)


6/F, the 3rd Phase of WanLi Industrial Building,
ShiHua Road, FuTian Free Trade Zone
Shenzhen, Guangdong, China
Tel: +86-755-33320018
Fax: +86-755-33320008

Test Facility:

Test facility was located at Pu Long Cun 69, Puxinghu Industrial


Area, Tangxia Town, Dongguan, Guangdong, P.R.China.

Accreditation:

The NVLAP Lab Code is 200707-0.

STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp.
(Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification,
approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government.
This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

Bay Area Compliance Laboratories Corp. (Shenzhen)


6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China

1. Product Description
General Information:
Sample No.:RSZ131022510-S01 Model: HBCC20 One sample was received on 2013-10-22 and used for testing.
Model Tested:

HBCC20

Manufacturer:

ATG Electronics Corp

Brand Name:

ATG

Product Designation:
Burning Time Before Test:

HighBay
0 hour(For New Products)

Rated Values:
Rated Voltage/Frequency:

100-277 VAC 50/60Hz

Rated Power:

200W

Nominal CCT:

5000K

2. Standards Used

IESNA LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products
ANSI C82.77-2002: Harmonic Emission Limits Related Power Quality Requirements for Lighting

3. Description of Test Equipment


Device

Manufacture

Model No

Serial No

Test Range

Calibration date

1.5m temperature
integrating sphere

SENSING

SPR-600

S09008

2550

2013-03-08

Spectral radiation analyzer

SENSING

SPR3000

90902027

350nm800nm

2013-03-08

Digital power meter

YOKOGAWA

WT-210

91j926132

15/30/60/150/300/60
0V

2013-03-25

Precision frequency power


supply

ALL Power

APW-105N

970613

0V-300V 50-400Hz

2013-03-25

Standard Light Source

SENSING

N/A

LSD090808

N/A

2013-05-13

Temperature/humidity/clock

Victor

VC230

EE209

0~400~90%

2013-04-01

0~60V

2013-03-25

Programmable Precision DC
Power Supply

ITECH

IT6154

0061 0417
6471 0010 19

AC POWER SUPPLY

EVERFINE

VPS1060 PWM

1101006

0-150V 0-300V

2013-03-25

Digital CC&CV DC Power


Supply

EVERFINE

WY12010

1009009

30V/5A

2013-03-25

Electrical parameter tester

YOKOGAWA

WT-210

91KB35700

15/30/60/150/300/60
0V

2013-03-25

full-field speed
goniophotometer

EVERFINE

GO-R5000

YG108492N1
1600mm,3000W/10A
0120001

2013-03-08

Temperature/humidity/clock

Victor

VC230

EE091

0~400~90%

2013-04-01

Standard Light Source

EVERFINE

D908

1012001

N/A

2013-05-28

Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been
performed using suitable standards traceable to National Primary Standards and International System of Units (SI).

Report No. RSZ131022510-10

Page 2 of 13

The NVLAP Lab Code is 200707-0.

Bay Area Compliance Laboratories Corp. (Shenzhen)


6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China

4. Test Method
Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-7908. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of the
sample was maintained at 25C1C during measurement. And relative humidity is less than 65%.
Integrating Sphere System
The system includes AC power source, digital power meter, DC power supply, spectrophotometer, and integrating
sphere. The integrating sphere system is calibrated by standard light source before measurement.
4 geometry was used during measurement. The product was operated in its intended orientation in application and
was recorded in this report.
The uncertainty of the light output (luminous flux) measurements is U=1.70% (K=2), at the 95% confidence level. The
uncertainty of the correlated color temperature measurements is U=21K (K=2), at the 95% confidence level. The
uncertainty of the CRI is U=1.4(K=2) , at the 95% confidence level.
Goniophotometer System
The goniophotometer system is calibrated by standard light source before measurement.
Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial
uniformity. The product was operated in its intended orientation in application and was recorded in this report.
The uncertainty of the luminous intensity is U=2.82% (K=2) , at the 95% confidence level.
Additional Test
The Additional Test item may not be covered by IESNA LM-79-2008. Additional test including power factor, off-state
power and THD, was measured by Digital Power Meter after stabilized at 25C1C.Test voltage for THD and power
factor test would be equal to rated voltage or, in case of a voltage range, maximum value of that range.

Report No. RSZ131022510-10

Page 3 of 13

The NVLAP Lab Code is 200707-0.

Bay Area Compliance Laboratories Corp. (Shenzhen)


6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China

5. Test Result
[Integrating Sphere System]
Total operating time for integrating sphere test: 1.5 hours
Test orientation: Downward

Electrical Measurement
Voltage (V)

Frequency (Hz)

Current (A)

Power (W)

Power Factor

120.07

60.0

1.7251

206.33

0.996

Luminous Flux (lm)

Radiant Flux (W)

Efficacy (lm/W)

CCT (K)

Duv

18456.942

39.878

89.454

5292

4.02E-03

Photometric Measurement

Chromaticity Coordinate
x

u'

v'

0.3378

0.3536

0.2057

0.3230

0.2057

0.4846

Color Rendering Index


Ra
82.1
R1

R2

R3

R4

82

84

86

84

R5

R6

R7

R8

82

79

87

72

R9

R10

R11

R12

15

63

84

58

R13

R14

R15

83

92

77

Report No. RSZ131022510-10

Page 4 of 13

The NVLAP Lab Code is 200707-0.

Bay Area Compliance Laboratories Corp. (Shenzhen)


6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China

Relative Spectral Power Distribution


1.2
1.0
0.8
0.6
0.4
0.2
0.0
380

440

500

560

620

680

740

800

nm

mW

nm

mW

nm

mW

nm

mW

nm

mW

380

3.504E-02

465

5.834E-01

550

9.443E-01

635

6.168E-01

720

7.830E-02

385

2.331E-02

470

4.116E-01

555

9.358E-01

640

5.684E-01

725

6.783E-02

390

1.563E-02

475

3.090E-01

560

9.297E-01

645

5.187E-01

730

5.895E-02

395

1.185E-02

480

2.836E-01

565

9.252E-01

650

4.731E-01

735

5.136E-02

400

9.301E-03

485

3.036E-01

570

9.202E-01

655

4.300E-01

740

4.458E-02

405

9.814E-03

490

3.612E-01

575

9.225E-01

660

3.862E-01

745

3.939E-02

410

1.569E-02

495

4.503E-01

580

9.222E-01

665

3.474E-01

750

3.487E-02

415

3.179E-02

500

5.635E-01

585

9.254E-01

670

3.056E-01

755

3.109E-02

420

7.236E-02

505

6.696E-01

590

9.239E-01

675

2.706E-01

760

2.756E-02

425

1.611E-01

510

7.770E-01

595

9.238E-01

680

2.383E-01

765

2.456E-02

430

3.235E-01

515

8.555E-01

600

9.148E-01

685

2.070E-01

770

2.235E-02

435

5.881E-01

520

9.204E-01

605

8.894E-01

690

1.817E-01

775

2.003E-02

440

1.012E+00

525

9.564E-01

610

8.607E-01

695

1.570E-01

780

1.805E-02

445

1.573E+00

530

9.722E-01

615

8.254E-01

700

1.361E-01

785

1.645E-02

450

1.706E+00

535

9.687E-01

620

7.778E-01

705

1.181E-01

790

1.548E-02

455

1.257E+00

540

9.717E-01

625

7.234E-01

710

1.033E-01

795

1.413E-02

460

8.166E-01

545

9.551E-01

630

6.671E-01

715

8.976E-02

800

1.322E-02

Report No. RSZ131022510-10

Page 5 of 13

The NVLAP Lab Code is 200707-0.

Bay Area Compliance Laboratories Corp. (Shenzhen)


6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China

CIE 1931 x y Chromaticity Diagram


0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0
0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

7-Step & 4-Step Chromaticity Quadrangles


0.45

sample
7-STEP 2700K
7-STEP 3000K
7-STEP 3500K
7-STEP 4000K
7-STEP 4500K
7-STEP 5000K
7-STEP 5700K
7-STEP 6500K
4-STEP 2700K
4-STEP 3000K
4-STEP 3500K
4-STEP 4000K
4-STEP 5000K
4-STEP 6500K

0.40

0.35

0.30
0.30

Report No. RSZ131022510-10

0.35

0.40

Page 6 of 13

0.45

0.50

The NVLAP Lab Code is 200707-0.

Bay Area Compliance Laboratories Corp. (Shenzhen)


6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China

[Goniophotometer System]
Total operating time for luminous intensity distribution: 2.0 hours
Test orientation: Downward

Electrical Measurement
Input Voltage (V)

Frequency (Hz)

Input Current (A)

Power (W)

Power Factor

120.0

60.0

1.758

210.1

0.9954

Luminous Flux (lm)

Efficacy (lm/W)

CBCP (cd)

S/MH (C0/180)

S/MH (C90/270)

19107.5

90.95

17131

0.86

0.87

Photometric Measurement

Luminous Intensity Distribution

C0/180

C45/225

C90/270

C135/315

AVG.

Beam Angle (50% Imax):

58.4

56.1

58.7

56.6

57.5

Field Angle (10% Imax):

97.9

88.8

98.3

88.2

93.3

Report No. RSZ131022510-10

Page 7 of 13

The NVLAP Lab Code is 200707-0.

Bay Area Compliance Laboratories Corp. (Shenzhen)


6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China

Luminous Intensity (cd) Distribution Data


C

0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0
95.0
100.0
105.0
110.0
115.0
120.0
125.0
130.0
135.0
140.0
145.0
150.0
155.0
160.0
165.0
170.0
175.0
180.0

22.5

45

67.5

90

112.5

135

157.5

17131
16127
15288
14302
13391
10234
7751
5773
4140
1852
1669
1275
1020
776
533
338
201
151
125
90
62
60
57
48
52
49
42
42
41
41
36
34
40
36
32
22
17

17131
16442
15670
14818
13008
10629
7706
5849
3904
1878
1730
1311
1011
807
530
325
192
149
122
84
61
56
51
42
41
39
37
40
41
38
36
34
37
35
30
21
17

17131
16969
18487
15142
12503
10768
7763
6147
2791
1768
1669
1292
931
739
469
281
180
131
113
97
68
56
49
45
45
45
45
44
41
37
37
39
39
37
31
23
18

17131
16817
16199
14994
13469
10704
7878
6128
3946
1837
1697
1304
1009
771
508
303
178
133
113
91
73
57
49
45
43
42
43
42
40
37
34
35
38
37
33
25
20

17131
16598
15752
14568
13905
10452
7973
6770
4198
1844
1667
1277
996
768
508
298
177
129
118
88
74
59
48
43
41
41
40
38
37
35
33
31
37
37
34
25
21

17131
16820
16041
15221
14836
11410
8448
6608
4035
1873
1713
1336
1030
791
518
297
174
132
111
88
72
56
48
43
41
41
42
41
39
36
33
34
37
33
28
20
20

17131
17008
18653
15911
14930
11777
8673
6442
3126
1745
1660
1317
966
748
484
288
175
130
113
89
66
53
46
43
43
43
42
42
41
36
36
40
39
37
28
21
18

17131
16760
16229
15238
14825
11381
8679
6774
4160
1883
1787
1377
1064
846
564
338
190
142
123
83
60
53
50
40
40
36
36
38
39
36
35
33
36
34
33
25
17

Report No. RSZ131022510-10

Page 8 of 13

The NVLAP Lab Code is 200707-0.

Bay Area Compliance Laboratories Corp. (Shenzhen)


6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China

Luminous Intensity (cd) Distribution Data (cont.)


C

0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0
95.0
100.0
105.0
110.0
115.0
120.0
125.0
130.0
135.0
140.0
145.0
150.0
155.0
160.0
165.0
170.0
175.0
180.0

180

202.5

225

247.5

270

292.5

315

337.5

17131
16519
15855
14721
14143
10837
8455
7069
4318
1953
1782
1366
1095
864
589
363
209
143
128
86
64
58
56
47
51
49
42
42
36
39
33
32
36
36
37
24
17

17131
16628
15994
15174
13994
10878
8384
6831
4114
1837
1755
1385
1077
852
572
341
194
148
131
85
66
55
51
40
40
39
38
40
42
38
36
33
36
33
32
24
17

17131
16760
18426
15074
13648
11162
8482
6474
3272
1668
1618
1337
998
778
515
308
189
144
125
96
73
58
50
44
45
45
46
46
43
38
40
43
43
39
29
21
18

17131
16325
15465
14495
14133
10721
8486
6552
4143
1809
1727
1324
1056
811
549
329
203
153
125
100
79
62
52
47
45
45
47
46
44
40
35
37
40
35
30
19
20

17131
16159
15200
13958
13640
10551
8263
6607
4267
1901
1731
1363
1107
838
573
357
215
154
133
101
81
63
53
47
44
44
44
43
40
37
35
31
40
39
35
23
21

17131
16356
15562
14224
13258
10873
8160
6056
3683
1891
1729
1330
1075
867
588
348
217
164
126
99
78
61
51
47
45
44
47
45
42
39
35
36
41
38
33
24
20

17131
16474
18235
14496
13105
10772
8065
5692
2747
1744
1663
1253
972
770
495
314
207
147
123
100
72
56
50
44
45
46
48
47
44
38
40
43
41
38
31
23
18

17131
16217
15658
14368
13357
10682
7923
5774
3411
1744
1621
1255
1006
820
516
315
198
159
119
89
62
56
52
42
41
39
38
44
43
39
37
34
37
34
30
21
17

Report No. RSZ131022510-10

Page 9 of 13

The NVLAP Lab Code is 200707-0.

Bay Area Compliance Laboratories Corp. (Shenzhen)


6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China

Average Area Illumination Figure


Angle: 57.5 . Flux out: 10337.0 lm.

Report No. RSZ131022510-10

Height (m)

Diameter
(cm)

Eavg(lx)

Emax(lx)

0.5

54.9

42835.0

71493.0

1.0

109.7

10709.0

17873.0

1.5

164.6

4759.0

7944.0

2.0

219.4

2677.0

4468.0

2.5

274.3

1713.0

2860.0

3.0

329.2

1190.0

1986.0

3.5

384.0

874.2

1459.0

4.0

438.9

669.3

1117.0

4.5

493.8

528.8

882.6

5.0

548.6

428.3

714.9

Page 10 of 13

The NVLAP Lab Code is 200707-0.

Bay Area Compliance Laboratories Corp. (Shenzhen)


6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China

Zonal Lumen Density Measurement


Deg

Flux (lm)

Deg

Flux (lm)

0-5

401.2

2.10

0-5

401.2

2.10

5-10

1174.8

6.15

0-10

1576.0

8.25

10-15

1851.5

9.69

0-15

3427.5

17.94

15-20

2383.0

12.47

0-20

5810.5

30.41

20-25

2542.9

13.31

0-25

8353.4

43.72

25-30

2442.9

12.78

0-30

10796.3

56.50

30-35

2152.0

11.27

0-35

12948.3

67.77

35-40

1616.0

8.45

0-40

14564.2

76.22

40-45

1003.6

5.25

0-45

15567.9

81.47

45-50

711.5

3.73

0-50

16279.3

85.20

50-55

662.8

3.47

0-55

16942.2

88.67

55-60

535.5

2.80

0-60

17477.7

91.47

60-65

445.4

2.33

0-65

17923.0

93.80

65-70

338.3

1.77

0-70

18261.3

95.57

70-75

218.1

1.14

0-75

18479.4

96.71

75-80

132.5

0.70

0-80

18611.9

97.41

80-85

89.6

0.47

0-85

18701.6

97.88

85-90

73.0

0.38

0-90

18774.6

98.26

90-95

58.3

0.30

0-95

18832.9

98.56

95-100

43.1

0.23

0-100

18876.0

98.79

100-105

33.7

0.17

0-105

18909.7

98.96

105-110

28.2

0.15

0-110

18937.9

99.11

110-115

23.8

0.13

0-115

18961.7

99.24

115-120

21.5

0.11

0-120

18983.2

99.35

120-125

20.0

0.10

0-125

19003.2

99.45

125-130

18.5

0.10

0-130

19021.7

99.55

130-135

17.2

0.09

0-135

19038.9

99.64

135-140

15.4

0.08

0-140

19054.4

99.72

140-145

13.1

0.07

0-145

19067.5

99.79

145-150

10.7

0.06

0-150

19078.2

99.85

150-155

9.0

0.04

0-155

19087.2

99.89

155-160

7.6

0.04

0-160

19094.8

99.93

160-165

6.2

0.04

0-165

19101.1

99.97

165-170

4.1

0.02

0-170

19105.1

99.99

170-175

2.0

0.01

0-175

19107.1

100.00

175-180

0.5

0.00

0-180

19107.6

100.00

Report No. RSZ131022510-10

Page 11 of 13

The NVLAP Lab Code is 200707-0.

Bay Area Compliance Laboratories Corp. (Shenzhen)


6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China

[Additional Test]
Test Item

Test Voltage (V)

Frequency (Hz)

Test Result

Power Factor:

277

60

0.9214

Total Harmonic Distortion:

120

60

4.87%

Total Harmonic Distortion:

277

60

14.04%

Off State Power:

120

60

0.0W

6. Product Photo

Report No. RSZ131022510-10

Page 12 of 13

The NVLAP Lab Code is 200707-0.

Bay Area Compliance Laboratories Corp. (Shenzhen)


6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China

***********END OF REPORT***********

Report No. RSZ131022510-10

Page 13 of 13

The NVLAP Lab Code is 200707-0.

Você também pode gostar