Escolar Documentos
Profissional Documentos
Cultura Documentos
B* (roof)
3
2
2
576,94
576,94
C
C
C
C
M
3A
5
4
A
I, N
-
accuracy of inspection
soft-storey
M
M
C
C
C
other elements
present state
regularity
non-structural elements
roof
reinforced elements
N
1
structural typology
N
1
N
1
holes in facade
N
1
3C
N
1
8,57
8,57
8,57
interventions
4,96
age
3,20
building number
other informations
number
street
Type of information: C = one-alphanumeric character code; I = integer; N1 = number with one decimal digit; M = alphanumeric string with one or more
characters (multiple choice)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
n building
n storey
H first floor [m]
H max [m]
H min [m]
use
age
floor area [mq]
n storey on the main facade
H main facade [m]
joint
structural system
structural mesh
first level pillars dimensions
plan regularity
soft storey
first level infills
squat elements
structurl bow-windows
use
months of use
occupants
accuracy of inspections
global level
non-structural elements
I
I
I
I
I
I
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
E
G
1
2
1,2,4
B
E
G
3
C
F
H
1
existing
damage
C
F
H
1
C
D
I
2
M I
C
D
I
2
building number
utilization
use
residential
productive
commercial
office
public services and religious buildings
warehouse
strategic
tourism - accommodation facilities
n of occupants
null
D4-D5
D2-D3
D1
EMS level
null
D4-D5
D2-D3
D1
EMS level
null
D4-D5
D2-D3
D1
EMS level
null
D4-D5
D2-D3
D1
EMS level
null
D4-D5
D2-D3
D1
EMS level
null
D4-D5
D2-D3
D1
EMS level
I
C
4
C
A, C
infills and
partitions
C
C
C
C
M
Type of informations contained in columns: C = one-alphanumeric character code; I = integer; N1 = number with one decimal digit; M = alphanumeric string
with one or more characters (multiple choice)
BUILDING IN THE AGGREGATE (multiple choice)
1
isolated
A
same height
2
head
B
higher
3
corner
C
lower
4
inside
D
higher and smaller
5
backward
E
towering
6
protuding
F
staggered slabs (at different levels)
AGE
A
B
C
D
E
F
G
H
I
A*
< 1919
1919-1945
1946-1960
1961-1971
1972-1981
1982-1991
1992-2001
> 2001
________
different ages
INTERVENTIONS
A
enlargement
B
raising
C
renewal
D
restoration
E
maintenance
f
facade restoration
B*
partially demolished
R
no intervention
S
substitution (in the case of concrete substitution, complete r.c. schedule)
FLOOR AREA "The plan area of the building can be estimated through the use of the cartography, with maximum approximation of 10%.
AVERAGE FLOOR AREA
Fill out the average gross floor area of each storey of the building.
Fill out the average height of each storey of the building, approximated to 0,5 m.
"Fill out the maximum interstorey height measured for each storey, approximated to 0,5 m.
Fill out the maximum/minimum height of the building, estimated from the eaves.
Fill out the average height of the main facade, estimated from the eaves.
STRUCTURAL TYPOLOGY
1
only perimeter walls
2
interior walls
3
reinforced concrete above masonry
4
masonry above r.c.
5
masonry and r.c. on the same floor
6
reinforced masonry
7
confined masonry
VERTICAL STRUCTURES TYPOLOGY
A
Single leaf walls
B
cavity walls (or double leaf)
C
brick masonry
D
concrete blocks (heavy)
E
concrete blocks (light)
F
mixed structures
HORIZONTAL STRUCTURES TYPOLOGY
A
timber
B
timber with tie rods
C
metal beams with vaults or tiles
D
metal beams with vaults or tiles and tie rods
E
concrete and masonry or concrete slab
F
vaults without tie rods
G
vaults with tie rods
H
vaults and horizontal diaphragm
I
vaults and horizontal diaphragm with tie rods
L
metal beams with concrete slab
M
iron beams and brick tiles
ROOF
A
flat
B
C
D
E
F
G
H
A
regularity in plan and in elevation
regularity in elevation
regular plan
none
OTHER ELEMETS
A
arcade
B
loggia
C
external stairs
D
added bodies
E
isolated pillars
F
false walls
2
3
one flap
more flaps
G
H
I
L
M
N
overhanging
heavy roof
demolition of structural elements
non aligned holes
irregular strengthening
overhanging and towering/ standing out elements
REINFORCED ELEMENTS
A
buttresses and/or spurs
B
contrast elements
C
effective tie rods
D
confined openings
E
reinforced masonry with injections or non-reinforced plaster
F
reinforced masonry or with reinforced plaster
G
masonry with other or no indentified reinforcement
NON-STRUCTURAL ELEMENTS
A
absence of non-structural elements
B
well connected non-structural elements
C
poorly connected little elements
D
poorly connected big elements
PRESENT STATE
A
good conditions
B
medium conditions or widespread damage
C
bad conditions or medium damage
D
worst conditions or serious damage
Fill out the maximum/minimum height of the building, estimated from the ground to the eaves
residential
1=yes 2=no
productive
1=yes 2=no
public services 1=yes 2=no
AGE
A
B
C
D
E
F
G
< 1919
1919-1945
1946-1960
1961-1971
1972-1981
> 1981
________
FLOOR AREA The plan area of the building can be estimated through the use of the cartography, with maximum approximation of 10%
NUMBER OF STORIES OF THE MAIN FACADEFill out the number of the storey on the main facade. Attic should be excluded if its average height is less
than 20% of the avarege interstorey height of the building.
MAIN FACADE HEIGHT
Fill out the average height of the main facade, estimated from the ground to the eaves.
JOINT
1
2
3
isolated
according to law
not according to law
STRUCTURAL SYSTEM
A
prevalence of walls or frames with stiff masonry infills (without large holes and with resistant materials)
B
prevalence of frames with beams that are higher than the thickness of the horizontal diaphragms and bad quality infills
C
prevalence of frames with beams that have the same thickness of the horizontal diaphragms and bad quality or absent infills
D
frames with high beams on the perimeter with bad quality infills and beams that has the same thickness of the horizontal diaphragms
E
presence of frames with beams that are higher than the thickness of the horizontal diaphragms and r.c. walls
F
prevalence of r.c. walls
STRUCTURAL MESH
1
average distance between pillars < 4,5 m
2
average distance between pillars > 4,5 m and < 6 m
3
average distance between pillars > 6 m
FIRST LEVEL PILLARS DIMENSION
A
average dimension < 25 cm
B
average dimension > 25 cm and < 40 cm
C
average dimension > 40 cm
PLAN REGULARITY
1
compact and regular
2
compact and regular on the average
3
not compact and irregular
SOFT STOREY
1
absent
2
pilotis
3
4
neglected
not used (<10%)
partially used (10%-70%)
used (>70%)
MONTHS OF USE
OCCUPANTS
A
B
C
1 family
2 families
3-4 families
D
E
F
G
5-8 families
9-15 families
16-30 families
> 30 families
ACCURACY OF INSPECTION
A
from the outside inspection
B
partially internal inspection
C
complete inspection
EXPOSITION - UTILIZATION
A
> 65%
B
30% - 65%
C
< 30%
D
unused
E
under construction
F
not finished
G
neglected
EXPOSITION - USE
A
residential
B
productive
C
commercial
D
office
E
public services and religious buildings
F
warehouse
G
strategic
H
tourism - accommodation facilities
for each structural element fill out the damage extention corrispondant to different levels
DAMAGE - LEVEL/EXTENSION
>2/3 1/3-2/3
<1/3
D4-D5
A
B
C
D2-D3
D1
DAMAGE - EMS/GLOBAL LEVEL
code 0
1
structural
null
null
non-structural null
low
D
G
E
H
F
I
2
3
4
low
mean- severe partial collapse
severe /
/
/
5
total collapse