Você está na página 1de 4

INSTALACIONES ELCTRICAS

CALCULO DE LA MAXIMA DEMANDA


A. PRIMER PISO TD 01
A.1 VIVIENDA UNIFAMILIAR

AREA CONSTRUIDA
AREA LIBRE
THERMA vol = 130 litros

93.87
52.81
C.I.1

Watts/m2 Consumo (Watts )


25
2346.75
5
264.05
1500
1500
4110.8 Watts

CALCULO DEL CARGA INSTALADA TOTAL


C.I.T=(AREA CONST. + AREA LIBRE + CARGA)
C.I.T=
4110.8 watts

CALCULO DE LA MAXIMA DEMANDA


M.D=
M.D=
M.Dtherma=

M.D=C.I.Txfd
2000
610.8
1500
M.D=

TOTAL
100%
2000
35%
213.78
100%
1500
3713.78 watts

CALCULO DE LA INTENSIDAD DE CORRIENTE


I=
16.88 amperios
REDONDEANDO: 20 AMP. COMERCIAL
CABLE A USAR: # 12 THW COMERCIAL

B. SEGUNDO PISO TD 02
B.2. VIVIENDA UNIFAMILIAR

AREA CONSTRUIDA
AREA LIBRE
THERMA vol = 130 litros
C.I.1

Areas(m2)
Watts/m2 Consumo (Watts )
109.2
25
2730
35.56
5
177.8
0
1500
1500
4407.8 Watts

CALCULO DEL CARGA INSTALADA TOTAL


C.I.T=(AREA CONST. + AREA LIBRE + CARGA)
C.I.T=
4407.8 watts

CALCULO DE LA MAXIMA DEMANDA


M.D=
M.D=
M.Dtherma=

M.D=C.I.Txfd
2000
907.8
1500
M.D=

TOTAL
100%
2000
35%
317.73
100%
1500
3817.73 watts

CALCULO DE LA INTENSIDAD DE CORRIENTE


I=
17.35 amperios
REDONDENADO: 20 AMP COMERCIAL
CABLE A USAR: # 12 THW COMERCIAL
INSTALACIONES ELECTRICAS DE UNA VIVIENDA UNIFAMILIAR UBICADA EN EL Psje. CANTUTA N 1327, CERRITO DE
LA LIBERTAD PROVINCIA DE HUANCAYO DEPARTAMENTO DE JUNIN

INSTALACIONES ELCTRICAS

C.

AZOTEA TD 03:

C.1. VIVIENDA UNIFAMILIAR

Areas(m2)
Watts/m2 Consumo (Watts )
33.17
25
829.25
39.59
5
197.95
0
1500
1500
2527.2 Watts

AREA CONSTRUIDA
AREA LIBRE

THERMA vol = 130 litros


C.I.1

CALCULO DEL CARGA INSTALADA TOTAL


C.I.T=(AREA CONST. + AREA LIBRE + CARGA)
C.I.T=
2527.2 watts

CALCULO DE LA MAXIMA DEMANDA


M.D=
M.D=
M.Dtherma=

M.D=C.I.Txfd
1027.2
0
1500
M.D=

TOTAL
100%
1027.2
35%
0
100%
1500
2527.2 watts

CALCULO DE LA INTENSIDAD DE CORRIENTE


I=
11.49 amperios
REDONDEANDO: 16 AMP. COMERCIAL
CABLE A USAR: # 12 THW COMERCIAL

D.

TOTAL TG-01:

D.1. VIVIENDA UNIFAMILIAR

1 PISO TD 01:
I=

16.88 amperios

I=

17.35 amperios

I=

11.49 amperios

2 PISO TD 02:

AZOTEA TD 03:_

45.72 amperios
TOTAL TG 01 I=
REDONDEANDO: 50 AMP. COMERCIAL
CABLE A USAR: # 10 THW COMERCIAL

INSTALACIONES ELECTRICAS DE UNA VIVIENDA UNIFAMILIAR UBICADA EN EL Psje. CANTUTA N 1327, CERRITO DE
LA LIBERTAD PROVINCIA DE HUANCAYO DEPARTAMENTO DE JUNIN

INSTALACIONES ELCTRICAS

E.

CALCULO DE CAIDA DE TENSION:

E.1. VIVIENDA UNIFAMILIAR

1 FORMULA GENERAL DE CAIDA DE TENSION:

I= 40A
= 0.0175
L= 1M
S= 5,3mm2 (CALIBRE 10 THW)
K= 1.0 Monofacico

DATOS
0.0175
5.3

40
1
AV=

0.13

V CUMPLE

CALCULO DEL CONDUCTOR SEGN EL "A"

CALCULO DEL LA TUBERIA PVC - L EN PULGADAS

INSTALACIONES ELECTRICAS DE UNA VIVIENDA UNIFAMILIAR UBICADA EN EL Psje. CANTUTA N 1327, CERRITO DE