LM24A-F
Technical data
Electrical data
Functional data
Nominal voltage
Nominal voltage range
Power consumption In operation
At rest
For wire sizing
Connection
AC 24 V, 50/60 Hz / DC 24 V
AC 19.2 ... 28.8 V / DC 21.6 ... 28.8 V
1.5 W @ nominal torque
0.2 W
1.5 VA
Cable 1 m, 3 x 0.75 mm2
Angle of rotation
Running time
Sound power level
Damper rotation
Position indication
Safety
Protection class
Degree of protection
Mode of operation
Rated impulse voltage
Control pollution degree
Ambient temperature range
Non-operating temperature
Ambient humidity range
Maintenance
Dimensions
Weight
EMC
Certification
Dimensions / Weight
Safety notes
www.belimo.com
The actuator is not allowed to be used outside the specified field of application, especially in
aircraft or any other form of air transport.
Assembly must be carried out by trained personnel. Any legal regulations or regulations
issued by authorities must be observed during assembly.
The device may only be opened at the manufacturers site. It does not contain any parts that
can be replaced or repaired by the user.
The cable must not be removed from the device.
When calculating the required torque, the specifications supplied by the damper manufactur
ers (cross section, design, installation site), and the air flow conditions must be observed.
The device contains electrical and electronic components and is not allowed to be disposed
of as household refuse. All locally valid regulations and requirements must be observed.
/2
LM24A-F
Product features
Simple direct mounting
Simple direct mounting on the damper spindleby form-fit. The actuator, with its hollow shaft, is
placed over the 8 mm square spindle of the damper and secured by two screws.
Manual override
Manual override with push-button possible (the gear is disengaged for as long as the button is
pressed or remains locked).
Accessories
Electrical accessories
Mechnical accessories
Description
Data sheet
T2 - S..A..
T2 - P..A..
Various accessories
T2 - Z-TM..A../LM..A..
Electrical installation
Direction of rotation
3-point control
T
Notes
Connection via safety isolating transformer.
Other actuators can be connected in parallel.
Please note the performance data.
Open-close control
Wiring diagrams
0
1
3
Cable colours:
1 = black
2 = red
3 = white
0
1
Dimensions [mm]
47
61
Dimensional drawings
16
116
Damper spindle
/2
Length
20
100.5
5.2
30
66
28.5
20
22
94
41
www.belimo.com
70214-00004.D
LM..A..F / TM..A..F
ZF12-LMA
ZF10-LMA
ZF8-LMA
20 m
1 mm
65
www.belimo.com
/2
LM..A..F / TM..A..F
~
+
L
+
L
0
1
1
T
0
1
AC 24 V / DC 24 V
DC 48 ... 110 V
(LM72A..)
+
S1 S2 S3
+
S1 S2 S3
0...100%
LM24A.. LMC24A..
LM72A.. TMC24A..
LM24A-S.. TMC24A-S..
LM24AP5..
L
1
0...100%
~
2
DC 010 V
DC 210 V
LM24A-SR.. LMC24A-SR..
LM24A-SX.. TMC24A-SR..
LM24A-MF..
Y
U
+
3
DC 010 V
MP
LM24A-MP..
SG..24
DC 48 ... 110 V
(LM72A-SR..)
Y
U
S1 S2 S3
LM230A-S.. TMC230A-S..
AC 24 V / DC 24 V
S1 S2 S3
S1 S2 S3
0
1
LM230A.. LMC230A..
TMC230A..
Y
U
DC 0 ... 10 V
DC 2 ... 10 V
Y
U
DC 0 ... 10 V
DC 2 ... 10 V
LM72A-SR..
SG..24
!
N
LM230ASR..
/2
www.belimo.com
70214-00004.D
LM..A..F / TM..A..F
ZF12-LMA
ZF10-LMA
ZF8-LMA
20 m
1 mm
65
www.belimo.com
/2
LM..A..F / TM..A..F
~
+
L
+
L
0
1
1
T
0
1
AC 24 V / DC 24 V
DC 48 ... 110 V
(LM72A..)
+
S1 S2 S3
+
S1 S2 S3
0...100%
LM24A.. LMC24A..
LM72A.. TMC24A..
LM24A-S.. TMC24A-S..
LM24AP5..
L
1
0...100%
~
2
DC 010 V
DC 210 V
LM24A-SR.. LMC24A-SR..
LM24A-SX.. TMC24A-SR..
LM24A-MF..
Y
U
+
3
DC 010 V
MP
LM24A-MP..
SG..24
DC 48 ... 110 V
(LM72A-SR..)
Y
U
S1 S2 S3
LM230A-S.. TMC230A-S..
AC 24 V / DC 24 V
S1 S2 S3
S1 S2 S3
0
1
LM230A.. LMC230A..
TMC230A..
Y
U
DC 0 ... 10 V
DC 2 ... 10 V
Y
U
DC 0 ... 10 V
DC 2 ... 10 V
LM72A-SR..
SG..24
!
N
LM230ASR..
/2
www.belimo.com