Você está na página 1de 31

Proposed Cooling Loads.

mit
03/Mar/2014

INTEGRATED
ENVIRONMENTAL
SOLUTIONS LTD

Project Summary ASHRAE system loads ASHRAE room loads

Project summary

Building

Model data:
Project file
Proposed Cooling Loads.mit
Model floor area1
42882.24 ft2
2
Building Floor Area
42882.24 ft2
3
Building Volume
704695.13 ft3
Number of rooms in 'Building floor area'
25

ASHRAE Loads provides the


heating and cooling loads for
the building and rooms using the
ASHRAE Heat Balance Method.
For each analyzed zone, the
Heat Balance Method calculates
the conductive, convective, and
radiative heat balance for each
room surface and a heat balance
for the room air.

Building Form

Heating calculation data:


Results file
Calculated
Profile month
Outdoor winter design temp

cooling loads.htg
01:29 03/Mar/2014
January
8.6 F

The Heat Balance Method


directly solves these equations
and reports the results of each
calculation. It also allows for a
great deal of customization of
the simulation inputs.

Cooling calculation data:


Results file
Calculated
Profile month
Max outdoor temp. dry bulb
Max outdoor temp. wet bulb

cooling loads.clg
01:29 03/Mar/2014
May - Sep
93.7 F
75.7 F

A detailed description of the


Heat Balance Method can be
found in the 2005 ASHRAE
Fundamentals Handbook.

Design weather:
Source
ASHRAE design weather database
Weather location
Atlantic City Intl Airport, New Jersey
Monthly percentile:
For heating loads design weather
99.6 %
For cooling loads design weather
1.0 %

1. 'Model floor area' is the total


floor area of all rooms in the
building regardless of whether
they are conditioned
2. 'Building floor area' is the
total area of all rooms for which
'Include in building floor area' is
ticked in 'Room Data' (used for
loads metrics in this report)
3. 'Building volume' is the total
volume of all rooms for which
'Include in building floor area' is
ticked in 'Room Data'

Building Plan

ASHRAE system loads


System
name

Room heating plant


load (kBtu/h)
Sensible
Humid
A-Z
Hi/Lo
Hi/Lo
Main system 727.3
430.9

Outdoor primaryair
load (kBtu/h)
Mech vent Aux Vent
Hi/Lo
Hi/Lo
516.1
0.0

Plant load
kBtu/h
Hi/Lo
1,862.7

Btu/hft2
Hi/Lo
43.44

Heating loads:
Total room plant load
Total central plant load

System heating loads

Copyright 2012 Integrated Environmental Solutions Limited All rights reserved

727.3 kBtu/h
1,862.7 kBtu/h
43 Btu/hft
2

Cooling loads:
Total room plant load
Total central plant load

115.1 kBtu/h
1,014.4 kBtu/h
24 Btu/hft
2

Air flow rates:


Total room air flows
System Peak
name time

System cooling load

A-Z
Main
system

Jul
16:30

Room cooling
plant load
(kBtu/h)
Sens
De
hum
Hi/Lo

Hi/Lo

115.1

0.0

Outdoor primary
air load (kBtu/h)

Peak plant
load

Mech Mech Aux


Aux
vent vent
vent vent
sens
lat
sens
lat
Hi/Lo Hi/Lo Hi/Lo Hi/Lo

kBtu/h Btu/hf
t2

541.8

1,014.4 23.65

438.5

0.0

0.0

Hi/Lo

Hi/Lo

21298.4 cfm
0.5 cfm/ft2

System assignments:
Main
system

Main
system

Copyright 2012 Integrated Environmental Solutions Limited All rights reserved

0123VESTIBUL ELECTRIC
E
AL ROOM
0424CONFERE PRODUCTI
NCE
ON 2
0525BARRY'S RECEIVING
OFFICE
2606-MENS WOMENS
TOILET
TOILET
07-OPEN 27-MENS
PLAN
TOILET
OFFICE
2809COMPRES
WOMENS SOR ROOM
TOILET
2911-LUNCH MACHINE
ROOM
SHOP
1231-MEZZ 1
WOMENS 32-MEZZ 2
BATHROO
M
13-STOCK
ROOM
15-MENS
BATHROO
M
16INSPECTIO
N
17KITCHEN
18NETWORK
19-LAB
20PRODUCTI
ON
21 22RECEIVIN
G
MACHINE
SHOP

ASHRAE room loads


System

Room name

A-Z
Apply

Main system
Main system
Main system
Main system
Main system
Main system
Main system

Room heating loads

Main system
Main system
Main system
Main system
Main system
Main system
Main system
Main system
Main system
Main system
Main system
Main system
Main system
Main system
Main system
Main system
Main system
Main system

01-VESTIBULE
04-CONFERENCE
05-BARRY'S
OFFICE
06-MENS TOILET
07-OPEN PLAN
OFFICE
09-WOMENS
TOILET
11-LUNCH ROOM
12-WOMENS
BATHROOM
13-STOCK ROOM
15-MENS
BATHROOM
16-INSPECTION
17-KITCHEN
18-NETWORK
19-LAB
20-PRODUCTION
21 22-RECEIVING
MACHINE SHOP
23-ELECTRICAL
ROOM
24-PRODUCTION 2
25-RECEIVING
26-WOMENS
TOILET
27-MENS TOILET
28-COMPRESSOR
ROOM
29-MACHINE
SHOP
31-MEZZ 1
32-MEZZ 2

Floor
area
ft2

OA temp
(F)

Room conditions

DB

WB

Set
point
(F)
Hi/Lo

Supply
air
(F)
Hi/Lo

Sens
load
(Btu/h)
Hi/Lo

Supply
airflow
(cfm)
Hi/Lo

100.0
708.5
219.7

8.6
8.6

6.3
6.3

70.0
73.0
73.0

90.0
90
90

10000
9039
4199

150.0
486.0
225.8

165.3
87.4

8.6

6.3

73.0

90

4207

226.2

8.6

6.3

73.0

90

814

43.8

1,651.5

8.6

6.3

73.0

90

23709

1274.8

Hi/Lo

79.2

8.6

6.3

73.0

90

814

43.8

519.2

8.6

6.3

73.0

90

10466

562.7

222.4

8.6

6.3

73.0

90

1770

95.2

490.3

8.6

6.3

73.0

90

3947

212.2

131.1

8.6

6.3

73.0

90

1171

63.0

203.6
180.7
146.8
439.0
15,303.1

8.6
8.6
8.6
8.6
8.6

6.3
6.3
6.3
6.3
6.3

73.0
73.0
73.0
73.0
73.0

90
90
90
90
90

1620
1564
3251
7273
147528

87.1
84.1
174.8
391.1
7932.5

1,716.0

8.6

6.3

73.0

90

18915

1017.0

274.2

8.6

6.3

73.0

90

4168

224.1

10,305.7
2,021.7

8.6
8.6

6.3
6.3

73.0
73.0

90
90

86137
21665

4631.5
1164.9

102.9

8.6

6.3

73.0

90

478

25.7

113.6

8.6

6.3

73.0

90

502

27.0

151.9

8.6

6.3

73.0

90

1011

54.4

5,217.7

8.6

6.3

73.0

90

66844

3594.1

1,822.3
608.4

8.6
8.6

6.3
6.3

73.0
73.0

90
90

14594
4908

784.7
263.9

Copyright 2012 Integrated Environmental Solutions Limited All rights reserved

System

Room name

Floor
area
ft2

Peak
time
Month

A-Z
Apply

Main system
Main system
Main system
Main system
Main system
Main system
Main system
Main system

Peak room cooling loads

Main system
Main system
Main system
Main system
Main system
Main system
Main system
Main system

Main system
Main system
Main system
Main system
Main system
Main system
Main system
Main system
Main system

01VESTIBULE
04CONFERENCE
05-BARRY'S
OFFICE
06-MENS
TOILET
07-OPEN
PLAN OFFICE
09-WOMENS
TOILET
11-LUNCH
ROOM
12-WOMENS
BATHROOM
13-STOCK
ROOM
15-MENS
BATHROOM
16INSPECTION
17-KITCHEN
18-NETWORK
19-LAB
20PRODUCTION
21 22RECEIVING
MACHINE
SHOP
23ELECTRICAL
ROOM
24PRODUCTION
2
25RECEIVING
26-WOMENS
TOILET
27-MENS
TOILET
28COMPRESSO
R ROOM
29-MACHINE
SHOP
31-MEZZ 1
32-MEZZ 2

OA
temp
(F)
Time

DB

Room conditions
WB

Hi/Lo

Set
point
DB(F)
Hi/Lo

Supply
air
DB(F)
Hi/Lo

Sens
load
(Btu/h)
Hi/Lo

Lat
load
(Btu/h)
Hi/Lo

Supply
airflow
(cfm)
Hi/Lo

100.0

75.0

55.0

10000

1000

150.0

708.5

Jul

16:30

93.2

75.6

77.0

55

-9926

-1435

412.4

219.7

Sep

14:30

86.7

73.4

77.0

55

-3217

-435

133.7

165.3

Sep

13:30

85.1

73.0

77.0

55

-9349

-327

388.4

87.4

Jul

16:30

93.2

75.6

77.0

55

-639

-182

26.5

1,651.5

Sep

13:30

85.1

73.0

77.0

55

-39054

-3269

1622.7

79.2

Jul

16:30

93.2

75.6

77.0

55

-593

-158

24.6

519.2

Jul

09:30

80.7

72.1

77.0

55

-14950

-1051

621.2

222.4

Jul

16:30

93.2

75.6

77.0

55

-1588

-464

66.0

490.3

Jul

16:30

93.2

75.6

77.0

55

-3638

-967

151.2

131.1

Jul

16:30

93.2

75.6

77.0

55

-925

-273

38.4

203.6

Jul

16:30

93.2

75.6

77.0

55

-1436

-425

59.7

180.7
146.8
439.0

Jul
Jul
Jul

16:30
09:30
16:30

93.2
80.7
93.2

75.6
72.1
75.6

77.0
77.0
77.0

55
55
55

-1332
-2882
-12174

-365
-297
-889

55.3
119.7
505.8

15,303.1

Jul

16:30

93.2

75.6

77.0

55

-176892

-30983

7349.7

1,716.0

Aug

16:30

91.0

75.6

77.0

55

-12582

-3689

522.8

274.2

Jul

16:30

93.2

75.6

77.0

55

-1948

-572

80.9

10,305.7

Jul

16:30

93.2

75.6

77.0

55

-77042

-19551

3201.0

2,021.7

Jul

16:30

93.2

75.6

77.0

55

-15408

-4035

640.2

102.9

Jul

16:30

93.2

75.6

77.0

55

-732

-169

30.4

113.6

Jul

16:30

93.2

75.6

77.0

55

-800

-188

33.2

151.9

Jul

16:30

93.2

75.6

77.0

55

-1112

-248

46.2

5,217.7

Jul

09:30

80.7

72.1

77.0

55

-103855

-10499

4315.1

1,822.3
608.4

Jul
Jul

16:30
16:30

93.2
93.2

75.6
75.6

77.0
77.0

55
55

-16136
-4401

-3132
-1144

670.4
182.9

Copyright 2012 Integrated Environmental Solutions Limited All rights reserved

System

Room
name

Floor
area
ft2

A-Z

Hi/Lo

100.0

Main
system
Main
system
Main
system
Main
system
Main
system
Main
system
Main
system
Main
system

Cooling airflow summary

Main
system
Main
system
Main
system
Main
system
Main
system
Main
system
Main
system
Main
system
Main
system
Main
system
Main
system
Main
system
Main
system
Main
system
Main
system
Main
system

No.
people

Room conditions

Engineering checks

Supply
air
DB (F)
Hi/Lo

Sens
load
(Btu/h)
Hi/Lo

Supply
airflow
(cfm)
Hi/Lo

Outside
airflow
(cfm)
Hi/Lo

Air
changes
/hr
Hi/Lo

(cfm/
ft2)

(Btu/
h*ft2)

%
OA

Hi/Lo

Set
point
DB (F)
Hi/Lo

Hi/Lo

Hi/Lo

Hi/Lo

OA/
person
(cfm)
Hi/Lo

3.0

75.0

55.0

10000

150.0

15.0

6.00

1.50

30.0

20.0

15.0

12,134.4

0.9

77.0

55

9926

412.4

188.3

2.04

0.58

14.01

45.7

209.2

3,762.5

0.3

77.0

55

3217

133.7

58.4

2.13

0.61

14.64

43.7

194.7

2,831.4

0.2

77.0

55

9349

388.4

43.9

8.23

2.35

56.55

11.3

219.5

1,497.3

0.1

77.0

55

639

26.5

23.2

1.06

0.30

7.31

87.5

232.0

28,285.8

2.1

77.0

55

39054

1622.7

438.9

3.44

0.98

23.65

27.0

209.0

1,356.1

0.1

77.0

55

593

24.6

21.0

1.09

0.31

7.49

85.4

210.0

8,892.7

0.7

77.0

55

14950

621.2

138.0

4.19

1.20

28.79

22.2

197.1

3,809.6

0.3

77.0

55

1588

66.0

59.1

1.04

0.30

7.14

89.5

197.0

8,398.3

0.6

77.0

55

3638

151.2

130.3

1.08

0.31

7.42

86.2

217.2

2,246.0

0.2

77.0

55

925

38.4

34.9

1.03

0.29

7.05

90.9

174.5

3,487.1

0.3

77.0

55

1436

59.7

54.1

1.03

0.29

7.05

90.6

180.3

3,094.7

0.2

77.0

55

1332

55.3

48.0

1.07

0.31

7.37

86.8

240.0

2,514.2

0.2

77.0

55

2882

119.7

39.0

2.86

0.82

19.63

32.6

195.0

7,519.7

0.6

77.0

55

12174

505.8

116.7

4.04

1.15

27.73

23.1

194.5

15,303.1 262,104.8

19.4

77.0

55

176892

7349.7

4,066.6

1.68

0.48

11.56

55.3

209.6

1,716.0

29,391.3

2.2

77.0

55

12582

522.8

456.0

1.07

0.30

7.33

87.2

207.3

274.2

4,696.6

0.4

77.0

55

1948

80.9

72.9

1.03

0.30

7.10

90.1

182.3

10,305.7 162,645.7

13.1

77.0

55

77042

3201.0

2,738.7

1.18

0.31

7.48

85.6

209.1

2,021.7

37,126.6

2.6

77.0

55

15408

640.2

537.3

1.03

0.32

7.62

83.9

206.7

102.9

890.8

0.1

77.0

55

732

30.4

27.3

2.05

0.30

7.12

89.8

273.0

113.6

983.7

0.1

77.0

55

800

33.2

30.2

2.03

0.29

7.04

91.0

302.0

151.9

1,315.8

0.2

77.0

55

1112

46.2

40.4

2.11

0.30

7.32

87.4

202.0

5,217.7

87,991.1

6.6

77.0

55

103855

4315.1

1,386.6

2.94

0.83

19.90

32.1

210.1

31-MEZZ 1 1,822.3

19,314.5

2.3

77.0

55

16136

670.4

484.3

2.08

0.37

8.85

72.2

210.6

32-MEZZ 2

8,404.4

0.8

77.0

55

4401

182.9

161.7

1.31

0.30

7.23

88.4

202.1

Apply

Main
system

Room
volume
ft3

01VESTIBUL 708.5
E
04CONFERE 219.7
NCE
05BARRY'S
165.3
OFFICE
06-MENS
87.4
TOILET
07-OPEN
PLAN
1,651.5
OFFICE
09WOMENS
79.2
TOILET
11-LUNCH 519.2
ROOM
12WOMENS 222.4
BATHROO
M
13-STOCK 490.3
ROOM
15-MENS
BATHROO 131.1
M
16INSPECTI
203.6
ON
17180.7
KITCHEN
18146.8
NETWORK
19-LAB
20PRODUCTI
ON
21 22RECEIVIN
G
MACHINE
SHOP
23ELECTRIC
AL ROOM
24PRODUCTI
ON 2
25RECEIVIN
G
26WOMENS
TOILET
27-MENS
TOILET
28COMPRES
SOR
ROOM
29MACHINE
SHOP

439.0

608.4

Copyright 2012 Integrated Environmental Solutions Limited All rights reserved

ASHRAE loads - room data summaries


01-VESTIBULE

01-VESTIBULE

Room input data


Geometry
Floor area (ft2 )
Volume (ft3 )
Ext. wall area (ft2 )
Int. wall area (ft2 )
Ext. window area (ft2 )
Int. window area (ft2 )
Skylight area (ft2 )
Room Data
Lighting load (W/ft2 )
Power load (W/ft2 )
Number of people
Area / person (ft2 )
Sens gain / pers
Latent gain / person
Heating set point (F)
Cooling set point (F)
Max rel. humidity %
Min rel. humidity %

708.5
12134.4
395.1
2,980.3
85.4
0.0
0.0
1.6
0.9
0.9
787.2
633.22
962.33
73.0
83.0
55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-259.3
Ext. Glazing
766.3
Skylights Conduction
0.0
Roof
587.6
Ground/Exposed Floor
-1173.0
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-3671.8
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-1509.4
Ext. Glazing
-2180.3
Skylights Conduction
0.0
Roof
-2167.2
Ground/Exposed Floor
-1628.6
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-129.1
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Solar Gains

6705.8

Solar Gains

0.0

Infiltration Gains

364.3

568.4

Infiltration Gains

-1424.8

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
3789.8
2245.9
569.9

0
Latent
0
0.0
866.1

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

9,926

1,435

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

324.0
0.46
1.60
188.3
58.1

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-9,039

486.0
0.69
2.40
188.3
38.7

04-CONFERENCE

04-CONFERENCE

Room input data


Geometry
219.7
Floor area (ft2 )
3762.5
Volume (ft3 )
530.9
Ext. wall area (ft2 )
500.7
Int. wall area (ft2 )
22.4
Ext. window area (ft2 )
0.0
Int. window area (ft2 )
0.0
Skylight area (ft2 )
Room Data
1.3
Lighting load (W/ft2 )
0.9
Power load (W/ft2 )
Number of people
0.3
732.3
Area / person (ft2 )
Sens gain / pers
589.00
Latent gain / person
894.67
Heating set point (F)
73.0
Cooling set point (F)
Max rel. humidity %
Min rel. humidity %

83.0
55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-599.5
Ext. Glazing
128.4
Skylights Conduction
0.0
Roof
37.1
Ground/Exposed Floor
-272.1
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-574.3
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-2013.1
Ext. Glazing
-572.0
Skylights Conduction
0.0
Roof
-691.5
Ground/Exposed Floor
-517.1
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
36.3
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Solar Gains

2622.7

Solar Gains

0.0

Infiltration Gains

61.1

166.4

Infiltration Gains

-441.8

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
940.0
696.4
176.7

0
Latent
0
0.0
268.4

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

3,216

435

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

105.0
0.48
1.67
58.4
55.6

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-4,199

225.8
1.03
3.60
58.4
25.9

05-BARRY'S OFFICE

05-BARRY'S OFFICE

Room input data


Geometry
165.3
Floor area (ft2 )
2831.4
Volume (ft3 )
166.3
Ext. wall area (ft2 )
632.6
Int. wall area (ft2 )
99.0
Ext. window area (ft2 )
0.0
Int. window area (ft2 )
0.0
Skylight area (ft2 )
Room Data
1.2
Lighting load (W/ft2 )
0.9
Power load (W/ft2 )
Number of people
0.2
826.5
Area / person (ft2 )
Sens gain / pers
664.50
Latent gain / person
1,009.50
Heating set point (F)
73.0
Cooling set point (F)
Max rel. humidity %
Min rel. humidity %

83.0
55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-725.8
Ext. Glazing
338.5
Skylights Conduction
0.0
Roof
-57.3
Ground/Exposed Floor
-1295.6
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-2910.4
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-624.8
Ext. Glazing
-2498.5
Skylights Conduction
0.0
Roof
-508.6
Ground/Exposed Floor
-378.9
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
136.2
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Solar Gains

12646.5

Solar Gains

0.0

Infiltration Gains

36.1

125.2

Infiltration Gains

-332.5

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
660.2
524.1
132.9

0
Latent
0
0.0
201.9

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

9,349

327

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

305.2
1.85
6.47
43.9
14.4

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-4,207

226.2
1.37
4.79
43.9
19.4

06-MENS TOILET

06-MENS TOILET

Room input data


Geometry
87.4
Floor area (ft2 )
1497.3
Volume (ft3 )
0.0
Ext. wall area (ft2 )
650.0
Int. wall area (ft2 )
0.0
Ext. window area (ft2 )
0.0
Int. window area (ft2 )
0.0
Skylight area (ft2 )
Room Data
0.8
Lighting load (W/ft2 )
0.9
Power load (W/ft2 )
Number of people
0.1
874.0
Area / person (ft2 )
Sens gain / pers
703.00
Latent gain / person
1,070.00
Heating set point (F)
73.0
Cooling set point (F)
Max rel. humidity %
Min rel. humidity %

83.0
55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
0.0
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
91.6
Ground/Exposed Floor
-21.5
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-67.5
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
0.0
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
-270.7
Ground/Exposed Floor
-204.2
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-163.3
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Solar Gains

0.0

Solar Gains

0.0

Infiltration Gains

50.0

76.4

Infiltration Gains

-175.8

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
249.4
277.1
70.3

0
Latent
0
0.0
107.0

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

649

183

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

20.9
0.24
0.84
23.2
111.0

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-814

43.8
0.50
1.76
23.2
53.0

07-OPEN PLAN OFFICE

07-OPEN PLAN OFFICE

Room input data


Geometry
Floor area (ft2 )
Volume (ft3 )
Ext. wall area (ft2 )
Int. wall area (ft2 )
Ext. window area (ft2 )
Int. window area (ft2 )
Skylight area (ft2 )
Room Data
Lighting load (W/ft2 )
Power load (W/ft2 )
Number of people
Area / person (ft2 )
Sens gain / pers
Latent gain / person
Heating set point (F)

1651.5
28285.8
787.3
2,457.8
375.7
0.0
0.0
1.0
0.9
2.1
786.4
632.57
961.19
73.0

Cooling set point (F)

83.0

Max rel. humidity %


Min rel. humidity %

55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-3023.7
Ext. Glazing
1687.8
Skylights Conduction
0.0
Roof
-317.6
Ground/Exposed Floor
-6707.6
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-9825.6
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-2968.4
Ext. Glazing
-9521.2
Skylights Conduction
0.0
Roof
-4884.6
Ground/Exposed Floor
-3647.8
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
634.1
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Solar Gains

44545.1

Solar Gains

0.0

Infiltration Gains

360.3

1250.5

Infiltration Gains

-3321.3

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
5771.8
5235.1
1328.4

0
Latent
0
0.0
2018.5

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

39,054

3,269

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

1274.9
0.77
2.70
438.9
34.4

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-23,709

1274.8
0.77
2.70
438.9
34.4

09-WOMENS TOILET

09-WOMENS TOILET

Room input data


Geometry
79.2
Floor area (ft2 )
1356.1
Volume (ft3 )
0.0
Ext. wall area (ft2 )
635.3
Int. wall area (ft2 )
0.0
Ext. window area (ft2 )
0.0
Int. window area (ft2 )
0.0
Skylight area (ft2 )
Room Data
0.8
Lighting load (W/ft2 )
0.9
Power load (W/ft2 )
Number of people
0.1
792.0
Area / person (ft2 )
Sens gain / pers
635.00
Latent gain / person
969.00
Heating set point (F)
73.0
Cooling set point (F)
Max rel. humidity %
Min rel. humidity %

83.0
55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
0.0
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
81.0
Ground/Exposed Floor
-24.6
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-38.1
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
0.0
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
-245.9
Ground/Exposed Floor
-185.5
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-223.4
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Solar Gains

0.0

Solar Gains

0.0

Infiltration Gains

43.7

67.5

Infiltration Gains

-159.2

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
226.0
251.0
63.5

0
Latent
0
0.0
96.9

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

603

164

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

19.4
0.24
0.86
21.0
108.2

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-814

43.8
0.55
1.94
21.0
47.9

11-LUNCH ROOM

11-LUNCH ROOM

Room input data


Geometry
519.2
Floor area (ft2 )
8892.7
Volume (ft3 )
661.5
Ext. wall area (ft2 )
785.3
Int. wall area (ft2 )
179.6
Ext. window area (ft2 )
0.0
Int. window area (ft2 )
0.0
Skylight area (ft2 )
Room Data
0.4
Lighting load (W/ft2 )
0.9
Power load (W/ft2 )
Number of people
0.7
741.7
Area / person (ft2 )
Sens gain / pers
596.43
Latent gain / person
906.71
Heating set point (F)
73.0
Cooling set point (F)

83.0

Max rel. humidity %


Min rel. humidity %

55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-2174.3
Ext. Glazing
342.1
Skylights Conduction
0.0
Roof
-4.3
Ground/Exposed Floor
-2917.8
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-3133.4
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-2475.4
Ext. Glazing
-4510.2
Skylights Conduction
0.0
Roof
-1566.3
Ground/Exposed Floor
-1165.8
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
295.7
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Solar Gains

20030.2

Solar Gains

0.0

Infiltration Gains

40.7

416.5

Infiltration Gains

-1044.2

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
703.5
1645.8
417.5

0
Latent
0
0.0
634.7

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

14,950

1,051

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

488.1
0.94
3.29
138.0
28.3

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-10,466

562.8
1.08
3.80
138.0
24.5

12-WOMENS BATHROOM

12-WOMENS BATHROOM

Room input data


Geometry
Floor area (ft2 )
Volume (ft3 )
Ext. wall area (ft2 )
Int. wall area (ft2 )
Ext. window area (ft2 )
Int. window area (ft2 )
Skylight area (ft2 )
Room Data
Lighting load (W/ft2 )
Power load (W/ft2 )
Number of people
Area / person (ft2 )
Sens gain / pers
Latent gain / person
Heating set point (F)

222.4
3809.6
0.0
1,038.9
0.0
0.0
0.0
0.9
0.9
0.3
741.3
596.33
906.67
73.0

Cooling set point (F)

83.0

Max rel. humidity %


Min rel. humidity %

55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
0.0
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
233.9
Ground/Exposed Floor
-50.8
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-252.6
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
0.0
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
-673.8
Ground/Exposed Floor
-508.1
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-140.8
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Solar Gains

0.0

Solar Gains

0.0

Infiltration Gains

131.3

194.5

Infiltration Gains

-447.3

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
666.4
705.1
178.9

0
Latent
0
0.0
272.0

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

1,612

466

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

51.8
0.23
0.82
59.1
114.1

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-1,770

95.2
0.43
1.50
59.1
62.1

13-STOCK ROOM

13-STOCK ROOM

Room input data


Geometry
Floor area (ft2 )
Volume (ft3 )
Ext. wall area (ft2 )
Int. wall area (ft2 )
Ext. window area (ft2 )
Int. window area (ft2 )
Skylight area (ft2 )
Room Data
Lighting load (W/ft2 )
Power load (W/ft2 )
Number of people
Area / person (ft2 )
Sens gain / pers
Latent gain / person
Heating set point (F)

490.3
8398.3
0.0
1,621.7
0.0
0.0
0.0
1.5
0.9
0.6
817.2
657.50
999.00
73.0

Cooling set point (F)

83.0

Max rel. humidity %


Min rel. humidity %

55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
0.0
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
476.0
Ground/Exposed Floor
-246.4
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-1177.9
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
0.0
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
-1464.9
Ground/Exposed Floor
-1103.3
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-392.9
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Solar Gains

0.0

Solar Gains

0.0

Infiltration Gains

274.8

423.3

Infiltration Gains

-986.1

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
2448.1
1554.4
394.5

0
Latent
0
0.0
599.4

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

3,723

1,023

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

118.8
0.24
0.85
130.3
109.7

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-3,947

212.2
0.43
1.52
130.3
61.4

15-MENS BATHROOM

15-MENS BATHROOM

Room input data


Geometry
131.1
Floor area (ft2 )
2246.0
Volume (ft3 )
0.0
Ext. wall area (ft2 )
814.3
Int. wall area (ft2 )
0.0
Ext. window area (ft2 )
0.0
Int. window area (ft2 )
0.0
Skylight area (ft2 )
Room Data
0.8
Lighting load (W/ft2 )
0.9
Power load (W/ft2 )
Number of people
0.2
655.5
Area / person (ft2 )
Sens gain / pers
526.50
Latent gain / person
800.50
Heating set point (F)
73.0
Cooling set point (F)

83.0

Max rel. humidity %


Min rel. humidity %

55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
0.0
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
140.9
Ground/Exposed Floor
-28.1
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-112.6
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
0.0
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
-401.7
Ground/Exposed Floor
-303.0
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-202.8
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Solar Gains

0.0

Solar Gains

0.0

Infiltration Gains

78.7

114.7

Infiltration Gains

-263.7

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
341.5
415.8
105.3

0
Latent
0
0.0
160.1

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

941

275

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

30.2
0.23
0.81
34.8
115.2

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-1,171

63.0
0.48
1.68
34.8
55.2

16-INSPECTION

16-INSPECTION

Room input data


Geometry
203.6
Floor area (ft2 )
3487.1
Volume (ft3 )
0.0
Ext. wall area (ft2 )
962.9
Int. wall area (ft2 )
0.0
Ext. window area (ft2 )
0.0
Int. window area (ft2 )
0.0
Skylight area (ft2 )
Room Data
1.0
Lighting load (W/ft2 )
0.9
Power load (W/ft2 )
Number of people
0.3
678.7
Area / person (ft2 )
Sens gain / pers
545.67
Latent gain / person
829.67
Heating set point (F)
73.0
Cooling set point (F)
Max rel. humidity %
Min rel. humidity %

83.0
55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
0.0
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
217.2
Ground/Exposed Floor
-44.2
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-343.5
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
0.0
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
-616.9
Ground/Exposed Floor
-465.2
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-128.5
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Solar Gains

0.0

Solar Gains

0.0

Infiltration Gains

122.1

178.0

Infiltration Gains

-409.5

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
697.1
645.4
163.7

0
Latent
0
0.0
248.9

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

1,458

427

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

46.9
0.23
0.81
54.1
115.4

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-1,620

87.1
0.43
1.50
54.1
62.1

17-KITCHEN

17-KITCHEN

Room input data


Geometry
180.7
Floor area (ft2 )
3094.7
Volume (ft3 )
0.0
Ext. wall area (ft2 )
903.3
Int. wall area (ft2 )
0.0
Ext. window area (ft2 )
0.0
Int. window area (ft2 )
0.0
Skylight area (ft2 )
Room Data
1.1
Lighting load (W/ft2 )
0.9
Power load (W/ft2 )
Number of people
0.2
903.5
Area / person (ft2 )
Sens gain / pers
726.00
Latent gain / person
1,103.50
Heating set point (F)
73.0
Cooling set point (F)

83.0

Max rel. humidity %


Min rel. humidity %

55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
0.0
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
183.8
Ground/Exposed Floor
-59.4
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-262.3
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
0.0
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
-548.3
Ground/Exposed Floor
-413.4
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-238.5
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Solar Gains

0.0

Solar Gains

0.0

Infiltration Gains

102.1

157.1

Infiltration Gains

-363.4

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
670.1
572.7
145.2

0
Latent
0
0.0
220.7

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

1,352

378

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

43.5
0.24
0.84
48.0
110.3

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-1,564

84.1
0.47
1.63
48.0
57.1

18-NETWORK

18-NETWORK

Room input data


Geometry
146.8
Floor area (ft2 )
2514.2
Volume (ft3 )
432.7
Ext. wall area (ft2 )
420.3
Int. wall area (ft2 )
23.2
Ext. window area (ft2 )
0.0
Int. window area (ft2 )
0.0
Skylight area (ft2 )
Room Data
1.6
Lighting load (W/ft2 )
0.9
Power load (W/ft2 )
Number of people
0.2
734.0
Area / person (ft2 )
Sens gain / pers
590.00
Latent gain / person
898.00
Heating set point (F)
73.0
Cooling set point (F)
Max rel. humidity %
Min rel. humidity %

83.0
55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-437.5
Ext. Glazing
74.0
Skylights Conduction
0.0
Roof
23.9
Ground/Exposed Floor
-455.8
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-1080.5
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-1630.8
Ext. Glazing
-589.0
Skylights Conduction
0.0
Roof
-471.5
Ground/Exposed Floor
-352.5
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
88.4
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Solar Gains

3378.0

Solar Gains

0.0

Infiltration Gains

11.5

117.8

Infiltration Gains

-295.2

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
785.2
465.4
118.0

0
Latent
0
0.0
179.6

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

2,882

297

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

94.1
0.64
2.25
39.0
41.4

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-3,251

174.8
1.19
4.17
39.0
22.3

19-LAB

19-LAB

Room input data


Geometry
Floor area (ft2 )
Volume (ft3 )
Ext. wall area (ft2 )
Int. wall area (ft2 )
Ext. window area (ft2 )
Int. window area (ft2 )
Skylight area (ft2 )
Room Data
Lighting load (W/ft2 )
Power load (W/ft2 )
Number of people
Area / person (ft2 )
Sens gain / pers
Latent gain / person
Heating set point (F)

439.0
7519.7
427.7
1,002.3
99.2
0.0
0.0
1.0
0.9
0.6
731.7
588.33
894.67
73.0

Cooling set point (F)

83.0

Max rel. humidity %


Min rel. humidity %

55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-1013.2
Ext. Glazing
799.8
Skylights Conduction
0.0
Roof
267.5
Ground/Exposed Floor
-2197.7
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-3218.0
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-1618.0
Ext. Glazing
-2519.8
Skylights Conduction
0.0
Roof
-1327.9
Ground/Exposed Floor
-992.6
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
67.8
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Solar Gains

13999.5

Solar Gains

0.0

Infiltration Gains

225.7

352.2

Infiltration Gains

-883.0

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
1565.9
1391.8
353.0

0
Latent
0
0.0
536.8

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

12,174

889

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

397.4
0.91
3.17
116.7
29.4

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-7,273

391.1
0.89
3.12
116.7
29.8

20-PRODUCTION

20-PRODUCTION

Room input data


Geometry
Floor area (ft2 )
Volume (ft3 )
Ext. wall area (ft2 )
Int. wall area (ft2 )
Ext. window area (ft2 )
Int. window area (ft2 )
Skylight area (ft2 )
Room Data
Lighting load (W/ft2 )
Power load (W/ft2 )
Number of people
Area / person (ft2 )
Sens gain / pers
Latent gain / person
Heating set point (F)

15303.0
262104.8
2,350.3
5,335.9
1,225.0
0.0
0.0
0.7
0.9
19.4
788.8
634.47
964.19
73.0

Cooling set point (F)

83.0

Max rel. humidity %


Min rel. humidity %

55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-7111.8
Ext. Glazing
9649.5
Skylights Conduction
0.0
Roof
11522.1
Ground/Exposed Floor
-34074.9
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-15946.7
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-8904.9
Ext. Glazing
-31208.5
Skylights Conduction
0.0
Roof
-44268.4
Ground/Exposed Floor
-33082.9
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
707.5
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Solar Gains

107818.3

Solar Gains

0.0

Infiltration Gains

7868.3

12277.6

Infiltration Gains

-30776.1

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
36342.0
48510.4
12308.8

0
Latent
0
0.0
18705.3

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

176,886

30,983

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

5774.7
0.38
1.32
4066.6
70.4

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-147,533

7932.5
0.52
1.82
4066.6
51.3

21 22-RECEIVING MACHINE SHOP

21 22-RECEIVING MACHINE SHOP

Room input data


Geometry
Floor area (ft2 )
Volume (ft3 )
Ext. wall area (ft2 )
Int. wall area (ft2 )
Ext. window area (ft2 )
Int. window area (ft2 )
Skylight area (ft2 )
Room Data
Lighting load (W/ft2 )
Power load (W/ft2 )
Number of people
Area / person (ft2 )
Sens gain / pers
Latent gain / person
Heating set point (F)
Cooling set point (F)
Max rel. humidity %
Min rel. humidity %

1716.0
29391.3
928.5
1,993.2
57.3
0.0
0.0
0.8
0.9
2.2
780.0
627.36
953.45
73.0
83.0
55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-917.8
Ext. Glazing
442.3
Skylights Conduction
0.0
Roof
1498.9
Ground/Exposed Floor
-756.1
Door
1023.7
Internal Conduction Gains
Sensible
Int. Walls
-2900.7
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-3526.0
Ext. Glazing
-1464.5
Skylights Conduction
0.0
Roof
-5070.1
Ground/Exposed Floor
-3800.1
Door
-1653.2
Internal Conduction Gains
Sensible
Int. Walls
50.5
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Solar Gains

1879.4

Solar Gains

0.0

Infiltration Gains

862.1

1610.2

Infiltration Gains

-3451.1

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
4650.9
5439.8
1380.2

0
Latent
0
0.0
2097.6

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

12,603

3,708

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

410.8
0.24
0.84
456.0
111.0

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-18,915

1017.0
0.59
2.08
456.0
44.8

23-ELECTRICAL ROOM

23-ELECTRICAL ROOM

Room input data


Geometry
274.2
Floor area (ft2 )
4696.6
Volume (ft3 )
529.2
Ext. wall area (ft2 )
823.4
Int. wall area (ft2 )
0.0
Ext. window area (ft2 )
0.0
Int. window area (ft2 )
0.0
Skylight area (ft2 )
Room Data
0.9
Lighting load (W/ft2 )
0.9
Power load (W/ft2 )
Number of people
0.4
685.5
Area / person (ft2 )
Sens gain / pers
551.00
Latent gain / person
838.00
Heating set point (F)
73.0
Cooling set point (F)
Max rel. humidity %
Min rel. humidity %

83.0
55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-31.6
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
303.4
Ground/Exposed Floor
-54.0
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-337.7
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-2022.2
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
-858.6
Ground/Exposed Floor
-644.0
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-92.0
Int. Glazing
0.0
Ceiling
0.0
Floor
0.0
Door
0.0

Solar Gains

0.0

Solar Gains

0.0

Infiltration Gains

162.9

239.8

Infiltration Gains

-551.5

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
847.0
869.2
220.4

0
Latent
0
0.0
335.2

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

1,980

575

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

63.6
0.23
0.81
72.9
114.6

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-4,168

224.1
0.82
2.86
72.9
32.5

24-PRODUCTION 2

24-PRODUCTION 2

Room input data


Geometry
Floor area (ft2 )
Volume (ft3 )
Ext. wall area (ft2 )
Int. wall area (ft2 )
Ext. window area (ft2 )
Int. window area (ft2 )
Skylight area (ft2 )
Room Data
Lighting load (W/ft2 )
Power load (W/ft2 )
Number of people
Area / person (ft2 )
Sens gain / pers
Latent gain / person
Heating set point (F)
Cooling set point (F)
Max rel. humidity %
Min rel. humidity %

10305.7
162645.7
1,766.1
5,946.9
583.6
0.0
0.0
0.5
1.4
13.1
786.7
632.77
961.60
73.0
83.0
55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-2860.7
Ext. Glazing
4694.2
Skylights Conduction
0.0
Roof
7140.5
Ground/Exposed Floor
-8264.6
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-8987.6
Int. Glazing
0.0
Ceiling
-4954.0
Floor
0.0
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-6674.1
Ext. Glazing
-14963.8
Skylights Conduction
0.0
Roof
-22650.0
Ground/Exposed Floor
-22530.5
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-285.5
Int. Glazing
0.0
Ceiling
65.4
Floor
0.0
Door
0.0

Solar Gains

10395.8

Solar Gains

0.0

Infiltration Gains

5263.7

8123.5

Infiltration Gains

-19097.7

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
19129.1
49003.5
8289.3

0
Latent
0
0.0
12596.9

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

78,849

20,720

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

2515.1
0.24
0.93
2738.7
108.9

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-86,136

4631.5
0.45
1.71
2738.7
59.1

25-RECEIVING

25-RECEIVING

Room input data


Geometry
Floor area (ft2 )
Volume (ft3 )
Ext. wall area (ft2 )
Int. wall area (ft2 )
Ext. window area (ft2 )
Int. window area (ft2 )
Skylight area (ft2 )
Room Data
Lighting load (W/ft2 )
Power load (W/ft2 )
Number of people
Area / person (ft2 )
Sens gain / pers
Latent gain / person
Heating set point (F)
Cooling set point (F)
Max rel. humidity %
Min rel. humidity %

2021.7
37126.6
643.9
2,811.3
0.0
0.0
0.0
0.8
1.4
2.6
777.6
625.50
950.50
73.0
83.0
55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-858.6
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
1890.8
Ground/Exposed Floor
-1392.8
Door
2896.5
Internal Conduction Gains
Sensible
Int. Walls
-4300.7
Int. Glazing
0.0
Ceiling
0.0
Floor
-339.1
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-2456.6
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
-5982.7
Ground/Exposed Floor
-3965.9
Door
-5066.9
Internal Conduction Gains
Sensible
Int. Walls
80.2
Int. Glazing
0.0
Ceiling
0.0
Floor
86.2
Door
0.0

Solar Gains

0.0

Solar Gains

0.0

Infiltration Gains

1167.7

1810.0

Infiltration Gains

-4359.4

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
5479.5
9613.2
1626.3

0
Latent
0
0.0
2471.3

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

15,783

4,281

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

503.0
0.25
0.81
537.3
106.8

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-21,665

1164.9
0.58
1.88
537.3
46.1

26-WOMENS TOILET

26-WOMENS TOILET

Room input data


Geometry
102.9
Floor area (ft2 )
890.8
Volume (ft3 )
0.0
Ext. wall area (ft2 )
358.6
Int. wall area (ft2 )
0.0
Ext. window area (ft2 )
0.0
Int. window area (ft2 )
0.0
Skylight area (ft2 )
Room Data
1.3
Lighting load (W/ft2 )
1.4
Power load (W/ft2 )
Number of people
0.1
1,029.0
Area / person (ft2 )
Sens gain / pers
827.00
Latent gain / person
1,258.00
Heating set point (F)
73.0
Cooling set point (F)

83.0

Max rel. humidity %


Min rel. humidity %

55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
0.0
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
0.0
Ground/Exposed Floor
-34.1
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-174.1
Int. Glazing
0.0
Ceiling
-95.4
Floor
0.0
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
0.0
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
0.0
Ground/Exposed Floor
-239.5
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-94.5
Int. Glazing
0.0
Ceiling
-39.8
Floor
0.0
Door
0.0

Solar Gains

0.0

Solar Gains

0.0

Infiltration Gains

30.8

47.0

Infiltration Gains

-104.6

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
440.1
489.1
82.7

0
Latent
0
0.0
125.8

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

739

173

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

23.9
0.23
1.61
27.3
114.2

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-478

25.7
0.25
1.73
27.3
106.2

27-MENS TOILET

27-MENS TOILET

Room input data


Geometry
113.6
Floor area (ft2 )
983.7
Volume (ft3 )
0.0
Ext. wall area (ft2 )
376.8
Int. wall area (ft2 )
0.0
Ext. window area (ft2 )
0.0
Int. window area (ft2 )
0.0
Skylight area (ft2 )
Room Data
1.3
Lighting load (W/ft2 )
1.4
Power load (W/ft2 )
Number of people
0.1
1,136.0
Area / person (ft2 )
Sens gain / pers
914.00
Latent gain / person
1,387.00
Heating set point (F)
73.0
Cooling set point (F)

83.0

Max rel. humidity %


Min rel. humidity %

55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
0.0
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
0.0
Ground/Exposed Floor
-32.7
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-225.1
Int. Glazing
0.0
Ceiling
-87.7
Floor
0.0
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
0.0
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
0.0
Ground/Exposed Floor
-264.0
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-77.2
Int. Glazing
0.0
Ceiling
-44.9
Floor
0.0
Door
0.0

Solar Gains

0.0

Solar Gains

0.0

Infiltration Gains

34.5

52.5

Infiltration Gains

-115.5

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
486.1
540.0
91.4

0
Latent
0
0.0
138.7

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

807

191

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

26.1
0.23
1.59
30.2
115.7

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-502

27.0
0.24
1.65
30.2
111.9

28-COMPRESSOR ROOM

28-COMPRESSOR ROOM

Room input data


Geometry
151.9
Floor area (ft2 )
1315.8
Volume (ft3 )
92.0
Ext. wall area (ft2 )
342.9
Int. wall area (ft2 )
0.0
Ext. window area (ft2 )
0.0
Int. window area (ft2 )
0.0
Skylight area (ft2 )
Room Data
0.6
Lighting load (W/ft2 )
1.4
Power load (W/ft2 )
Number of people
0.2
759.5
Area / person (ft2 )
Sens gain / pers
611.00
Latent gain / person
928.50
Heating set point (F)
73.0
Cooling set point (F)
Max rel. humidity %
Min rel. humidity %

83.0
55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-34.8
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
0.0
Ground/Exposed Floor
-54.7
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-77.0
Int. Glazing
0.0
Ceiling
65.0
Floor
0.0
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-354.5
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
0.0
Ground/Exposed Floor
-357.5
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-70.0
Int. Glazing
0.0
Ceiling
-74.0
Floor
0.0
Door
0.0

Solar Gains

0.0

Solar Gains

0.0

Infiltration Gains

43.8

67.3

Infiltration Gains

-154.5

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
332.9
722.4
122.2

0
Latent
0
0.0
185.7

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

1,120

253

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

36.3
0.24
1.66
40.4
111.3

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-1,011

54.3
0.36
2.48
40.4
74.4

29-MACHINE SHOP

29-MACHINE SHOP

Room input data


Geometry
Floor area (ft2 )
Volume (ft3 )
Ext. wall area (ft2 )
Int. wall area (ft2 )
Ext. window area (ft2 )
Int. window area (ft2 )
Skylight area (ft2 )
Room Data
Lighting load (W/ft2 )
Power load (W/ft2 )
Number of people
Area / person (ft2 )
Sens gain / pers
Latent gain / person
Heating set point (F)
Cooling set point (F)
Max rel. humidity %
Min rel. humidity %

5217.7
87991.0
2,745.3
3,582.3
801.1
0.0
0.0
0.7
1.4
6.6
790.6
635.88
966.32
73.0
83.0
55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-11111.6
Ext. Glazing
1727.9
Skylights Conduction
0.0
Roof
159.9
Ground/Exposed Floor
-22221.7
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-16070.4
Int. Glazing
0.0
Ceiling
0.0
Floor
-689.2
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-10360.1
Ext. Glazing
-20322.3
Skylights Conduction
0.0
Roof
-15289.0
Ground/Exposed Floor
-11059.1
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
441.2
Int. Glazing
0.0
Ceiling
0.0
Floor
75.2
Door
0.0

Solar Gains

110742.2

Solar Gains

0.0

Infiltration Gains

402.8

4121.0

Infiltration Gains

-10331.8

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
11909.1
24810.0
4196.8

0
Latent
0
0.0
6377.7

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

103,856

10,499

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

3390.4
0.65
2.31
1386.6
40.9

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-66,846

3594.2
0.69
2.45
1386.6
38.6

31-MEZZ 1

31-MEZZ 1

Room input data


Geometry
Floor area (ft2 )
Volume (ft3 )
Ext. wall area (ft2 )
Int. wall area (ft2 )
Ext. window area (ft2 )
Int. window area (ft2 )
Skylight area (ft2 )
Room Data
Lighting load (W/ft2 )
Power load (W/ft2 )
Number of people
Area / person (ft2 )
Sens gain / pers
Latent gain / person
Heating set point (F)
Cooling set point (F)
Max rel. humidity %
Min rel. humidity %

1822.3
19314.5
558.8
1,163.0
188.9
0.0
0.0
0.9
1.4
2.3
792.3
637.30
968.52
73.0
83.0
55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-1007.6
Ext. Glazing
1405.3
Skylights Conduction
0.0
Roof
1668.9
Ground/Exposed Floor
0.0
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-2335.0
Int. Glazing
0.0
Ceiling
0.0
Floor
-3537.3
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-2131.7
Ext. Glazing
-4837.7
Skylights Conduction
0.0
Roof
-5399.7
Ground/Exposed Floor
0.0
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-17.0
Int. Glazing
0.0
Ceiling
0.0
Floor
60.3
Door
0.0

Solar Gains

3346.0

Solar Gains

0.0

Infiltration Gains

579.8

904.7

Infiltration Gains

-2267.9

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
5885.1
8665.1
1465.8

0
Latent
0
0.0
2227.6

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

16,136

3,132

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

526.8
0.29
1.64
484.3
91.9

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-14,594

784.7
0.43
2.44
484.3
61.7

32-MEZZ 2

32-MEZZ 2

Room input data


Geometry
Floor area (ft2 )
Volume (ft3 )
Ext. wall area (ft2 )
Int. wall area (ft2 )
Ext. window area (ft2 )
Int. window area (ft2 )
Skylight area (ft2 )
Room Data
Lighting load (W/ft2 )
Power load (W/ft2 )
Number of people
Area / person (ft2 )
Sens gain / pers
Latent gain / person
Heating set point (F)

608.4
8404.4
479.5
1,025.7
0.0
0.0
0.0
1.0
1.4
0.8
760.5
611.88
929.50
73.0

Cooling set point (F)

83.0

Max rel. humidity %


Min rel. humidity %

55.0
45.0

Peak room cooling loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-342.0
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
622.6
Ground/Exposed Floor
0.0
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-1132.5
Int. Glazing
0.0
Ceiling
0.0
Floor
-373.7
Door
0.0

Latent
0
0
0
0
0
0
Latent
0
0
0
0
0

Peak room heating loads (Btu/h)


Exterior Conduction Gains
Sensible
Ext. Walls
-1827.1
Ext. Glazing
0.0
Skylights Conduction
0.0
Roof
-1850.5
Ground/Exposed Floor
0.0
Door
0.0
Internal Conduction Gains
Sensible
Int. Walls
-133.9
Int. Glazing
0.0
Ceiling
0.0
Floor
-109.5
Door
0.0

Solar Gains

0.0

Solar Gains

0.0

Infiltration Gains

284.8

435.9

Infiltration Gains

-986.8

Other air exchange gains


Internal Gains
Lighting
Equipment
People

0
Sensible
2044.6
2893.0
489.5

0
Latent
0
0.0
743.6

Other air exchange gains


Internal Gains
Lighting Gains
Equipment
People

0
Sensible
0.0
0.0
0.0

Totals

4,486

1,179

Totals

Cooling supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

143.7
0.24
1.03
161.7
112.5

Heating supply air volume (cfm)


cfm/ft2
ac/hr
Outside air volume (cfm)
% Outside air

-4,908

263.9
0.43
1.88
161.7
61.3