Updated 2012
Chemical Analysis
The Quality of an
Analysis is Never
Better than the
Quality of the
Sample
LOGAN ALUMINUM, Inc.
properties
Mechanical properties directly affect the
performance of our sheet products
On target with minimum variation
chemistry reduces product variation
chemical analysis
Defective samples adversely affect
Best
BestPractice:
Practice:Spark
SparkLocation
Locationand
andQuantity
Quantity
Samples of 3xxx alloy must have at least 2
good sparks evenly spaced. Samples of 5182
must have at least 3 good sparks evenly
spaced. Sparks on standards and production
samples should be approximately 3/8 in from
the edge. Sparking samples or standards
anywhere else is poor practice.
OES Standard
8 -10 mm (3/8)
production sample
2 -1/4 diameter
Our
Our Goal
Goal A
A good
good sample
sample
Good 5xxx
alloy spark
number (3
min) and
location
Good
Sample
flat
surfaces,
square
edges
C
Good 3xxx
alloy spark
number (2
min) and
location
Smooth
milled
surface
D
excellence through teamwork
Sample
Sample Defects
Defects
Shrinkage and
shrinkage
cavity, cold
metal, cold
mold,
solidification
rate too fast
F
E
LOGAN ALUMINUM, Inc.
Sample
Sample Defects
Defects
Rounded
edges
cold mold,
cold metal
Broken
sprue
G
LOGAN ALUMINUM, Inc.
H
excellence through teamwork
Sample
Sample Defects
Defects
Sprue too
big
affects
cooling
rate, hard
to remove
from mold
Sprue too
small
affects
cooling
rate and
shrinkage
cavity
location
I
LOGAN ALUMINUM, Inc.
Sample
Sample Defects
Defects
Dross
leading to
bad
sparks
Shrinkage cavity
from cold mold,
cold metal,
short sprue
and/or sprue
broken off
before complete
solidification
Sample
Sample Defects
Defects
Broken sprue
Sprue not
completely
removed
Cold shuts
Cold
mold, cold
metal,
blocked
vents
Rounded
edges
cold mold,
cold metal
O
Double
pour noncontinuous
pouring
Mold
not
closed
Flashing
mold
jaws
loose
Dimpled /
wavy
surface
blocked
vents
P
excellence through teamwork
Sample
Sample Defects
Defects
Flashing
mold
jaws
loose
Sprue
shear
damage
Seams and
flashing
mold
problem
Sprue not
centered
T
0
Sample
Sample Defects
Defects
Good
Sample
Tape on
samples is
unacceptable
U
Shrinkage,
See
sample K
above
Shrinkage
cavity
inside
sample
Bad sample,
Shrinkage and
shrinkage
cavity. See
sample K above
Incomplete
pouring
Sample
Sample Defects
Defects
Missing
spark, must
have 2
good
sparks for
3xxx alloy
or 3 good
sparks for
5xxx
Incorrect
spark
location
Our
Our Goal
Goal A
A good
good sample
sample
Good 5xxx
alloy spark
number (3
min) and
location
Good
Sample
flat
surfaces,
square
edges
C
Good 3xxx
alloy spark
number (2
min) and
location
Smooth
milled
surface
B
LOGAN ALUMINUM, Inc.
D
excellence through teamwork
Mg concentration (%)
5.00
sample 1
4.90
sample 2
4.80
sample 3
4.70
sample 4
sample 5
4.60
average
4.50
Depth of cut, mm
The example here is Mg segregation in 5182 alloy. Segregation occurs for all
elements to some degree in all alloys. Mg segregation in 5182 is very drastic
thus making a good example. Machining from the spure side of the sample has
been found to be best. Consistent depth of cut to the correct depth is critical for
obtaining representative chemistry of the melt.
10.0
9.0
8.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
0.2
4.40
Chemical Analysis
The Quality of an
Analysis is Never
Better than the
Quality of the
Sample
LOGAN ALUMINUM, Inc.
Spectrometer Schematic
Photomultiplier
Tubes
Vacuum Chamber
Spectrometer Housing
Primary Slit
Diffraction Grating
Lens
Profile Adjustment Knob
Automated OE Laboratory
RSI samples are fed into the automated
laboratory by the spiral magazine.
Samples are automatically analyzed
and then sorted.
Automated OE Laboratory
Automated OE Laboratory
OES Standard
Same Metallurgical
Structure
40
DC cast
3 dia. x 5 long
drop sample
excellence through teamwork
Sample
SamplePreparation
Preparation&&Sparking
SparkingOES
OESanalysis
analysis
When
Whenair
airis
isallowed
allowedto
toenter
enterspark
sparkstand
standbad
badburns
burnsresult
result
When using the old quantometer
sample
stand
sample backstop
electrode
Emission
Absorption
Energy
Excited
States
hc
h
Light
Ground State
OES sample
Concentration, % Mg
Ar
Argon
Argon + O2
+
+
Intensity
Counter-electrode
contaminated Ar (Argon)
leak in spark stand
oxides/oxygen in dross inside a chemical sample