Radar

Medium-textured panel

Indoor
Environmental
Quality

Classified as low-formaldehyde
according to standards established
by CHPS, the State of Washington,
ASHRAE, and ANSI.

Features and
Benefits

Non-directional pattern with a


fresh, clean appearance offers fast,
efficient installation.
Economical, all-purpose ceiling
pattern offered in many sizes.
Optional FIRECODE formulation
designed to meet life safety codes.

Applications

Schools
Corridors
Offices
Retail stores

Substrate

RADAR Panels/DONN Brand DX/DXL Suspension System

Water-felted mineral fiber

Radar

Acoustical Ceilings

Panel Size

RADAR Panels

Item No.

Technical Service 800 USG.4YOU


Web Site www.usg.com
Samples/Literature 888 874.2450
Samples/Literature Fax 888 874.2348
Customer Service 800 950.3839
Literature Number SC2288

UL Classified

Edge

Imperial
Metric (mm)1

Class2

Imperial NRC
Metric

CAC
Min.

LR3

Color

Grid
VOC
Options Class.4

Recycled Panel
Content5 Cost

(SQ)

2x2x5/8

Class A

2110

.55

33

.85

White

A, B, C

Low

28%

600x600x15

ME2110

2x2x5/8

2115

.55

35

.85

White

Low

48%

2310

.55

35

.85

White

A, B

Low

28%

2x4x5/8

(SLT)

Class A

600x1200x15

ME2310

2x4x5/8

2315

.55

35

.85

White

Low

48%

2x4x5/8

Class A

2310P 6

.55

35

.85

White

A, B

Low

28%

2x5x5/8

Class A

2619

.55

35

.85

White

A, B

Low

28%

20x60x5/8

Class A

2617

.55

35

.85

White

A, B

Low

28%

2x4x3/4

Class A

2311

.60

35

.85

White

A, B

Low

28%

30x60x3/4

Class A

2618

.60

35

.85

White

A, B

Low

28%

2x2x5/8

Class A

2120

.55

33

.85

White

Low

28%

600x600x15

ME2120

2x2x5/8

2125

.55

35

.85

White

Low

48%

2x4x5/8

Class A

2320

.55

35

.85

White

Low

28%

2x2x3/4

Class A

2121

.60

35

.85

White

Low

28%

(FLB)

2x2x5/8

Class A

2130

.55

33

.85

White

E, F, G

Low

28%

RADAR Tile7

(BESK)

12x12x5/8

Class A

2990

.508

408

.85

White

Low

28%

$$$

RADAR Illusion
Two/24 Panel

(SLT)3

2x4x3/4

Class A

2742

.55

35

.89

White

Low

28%

$$

The look of
2x2panels

Illusion Two/24

Pattern

A
DONN DX/
DXL

B
DONN DXW

C
CENTRICITEE

D
DONN DX/DXL

E
CENTRICITEE9

F
FINELINE 1/8

G
FINELINE

H
DONN DX/DXL
Concealed

Grid Profile Options

ASTM E1264
classification
Type III, Form 2,
Pattern C, D, E
ASTM E84 surface
burning characteristics
Class A
Flame spread: 25
Smoke developed: 10

Imperial weight
.69-.81 lb./sq. ft.
(Class A 5/8 panels)
1.00 lb./sq. ft. (Class A 3/4 panels)
1.10 lb./sq. ft. (Class A 5/8 tile)
1.15 lb./sq. ft. (FIRECODE panels)
Metric weight
3.37-3.95 kg/m2 (Class A
15 mm panels)

Thermal resistance
R-1.4 (Class A, 5/8 panels and tile)
R-1.7 (Class A, 3/4 panels)
R-1.4 (Class A,15 mm panels)
R-1.6 (FIRECODE, 5/8 panels)
Maximum backloading
See Warranty for details.
Maintenance
Can be cleaned easily with a soft
brush or vacuum.

Manufactured by
USG Interiors, Inc.
125 South Franklin Street
Chicago, IL 60606

Footnotes
1. Metric available in White only.
2. Fire-rated items: see UL design
details.
3. LR values are shown as averages.
4. Formaldehyde VOC Classification.
Classified as low-formaldehyde
according to standards established by
the Collaborative for High-Performance
Schools (CHPS), the State of Washington,
the American Society of Heating,
Refrigeration and Air-Conditioning

Engineers (ASHRAE), and the American


National Standards Institute (ANSI).
5. For details, see the Sustainability
Selector.
6. Includes plastic coating, GardnerScrubbability-tested to 3,000 cycles
(ASTM D246).
7. Contact USG for adhesive
recommendation for 12x12 glue-up
applications.
8. Not UL Classified for sound.
9. Maximum 2 x 2 for square panels.

Safety First!
Follow good safety and industrial
hygiene practices during handling and
installation of all products and systems.
Take necessary precautions and wear
the appropriate personal protective
equipment as needed. Read material
safety data sheets and related literature
on products before specification and/
or installation.

The following are trademarks of USG


Interiors, Inc. or a related company:
CENTRICITEE, DONN, DX, DXL, DXW,
FINELINE, FIRECODE, RADAR, USG.

SC2288/rev. 6-06
2006, USG Interiors, Inc.
Printed in U.S.A.

Você também pode gostar