Você está na página 1de 2

EZTRONIC EZP8

ECG for T8/


26mm fluorescent lamps

Technical information
Edition: Oct. 2011

EZP8 1x18/220-240
EZP8 1x36/220-240
EZP8 2x36/220-240

Subject to change

Applications :

For domestic use


Built-in ballast for luminaires in protection class I only
Valuable solution for flicker free light and energy saving in:
Commercial lighting - office, super market
School lighting
Industrial factory lighting
For easy replacement of magnetic ballast with minimum required changes to luminaires

Suitable for lighting with max. 3 switching cycles per day

Features:

Lamp start within 0.3 Sec.


Small size & same fixing centers as magnetic ballast for 1x models
Highly reliable
Automatic safety shut down at lamp failures
Automatic restart after lamp replacement 1)
20,000 hours lifetime with 10% max. failure rate at tcmax = 75C.

Product number
Reference
EZP8 1x18/220-240
EZP8 1x36/220-240
EZP8 2x36/220-240

EAN 10 / unpacked unit (1 pc)

EAN 40 / Package unit (50 pcs)

4008321 367471
4008321 367396
4008321 367457

4008321 367488
4008321 367402
4008321 367464

149mm

202mm

EZP8 1x18/220-240
EZP8 1x36/220-240

Lamp wiring:

Max. permitted cable length in between ECG and lamp:


2.0 m (PIN 21, 22); 1.0 m (PIN 23)

Page 1 of 2

EZP8 2x36/220-240
Master lamp

Max. permitted cable length in between ECG and lamp:


2.0 m (PIN 21, 22); 1.0 m (PIN 23,24)

EZTRONIC EZP8
ECG for T8/
26mm fluorescent lamps

Technical information
Edition: Oct. 2011

EZP8 1x18/220-240
EZP8 1x36/220-240
EZP8 2x36/220-240

Subject to change

Technical data:
Reference:

EZP8 1x18/220-240

EZP8 1x36/220-240

EZP8 2x36/220-240

Lamps:
HF Lamp wattage [W]
System wattage [W]
Line current [A]

L18W
16
20
0.080.09
Ip = 23 A; TH = 100 s

L36W
32
36
0.16
Ip = 23 A; TH = 100 s

2 x L36W
2 x 32
72
0.32
Ip = 22 A; TH = 240 s

Max. number of ECG, circuit


breaker 10A, Char. B / Char. C

34 / 54

34 / 54

15 / 24

Max. number of ECG, circuit


breaker 16A, Char. B / Char. C

56 / 89

56 / 89

25 / 40

Inrush current:

Max. cross section of wires for


2
push-in contact [mm ]
Starting time:
Mains input:
Voltage range (AC):
Operating frequency:
Electrical strength
Power factor:
Ambient temperature ta:
Measuring point temperature tc:
U-OUT:
Design (l x w x h):
Distance of fixing centers:
Terminals:
Weight:
Safety:
Radio interference:
Harmonic content:
Immunity:
Packaging unit:

0.51.0
t<0.3 sec.
220 -240V; 50/60Hz
198-264V
> 20 kHz
264V permanent

0.95
-10C...+50C
Max. + 75C
430V
149 x 42 x 30 mm
202 x 42 x 30 mm
139 mm
192 mm
45 Push-in (3+3)
45 Push-in (3+4)
85g
135g
Acc. to IEC 61347-2-3
Acc. to CISPR 15:2005 Edition 7 + A1:2006 including 30-300MHz CDN mode / EN55015
Acc. to IEC61000-3-2
Acc. to IEC61547
50pcs

Approval marks:

Remark: 1) Auto restart feature is on master lamp only. Please see below for more details.
Auto-restart Feature:
With the mains supply connected, the ECG can be auto-reset by simply rotating the MASTER Lamp after relamping. The MASTER Lamp must
be the last lamp to be inserted in order to avoid the mis-triggering of shutdown protection circuit.
Group-relamping is strongly recommended if bad lamp is detected in that fixture, to avoid confusion created by the mixture of new and used lamps
if only partial of lamps are replaced.
Relamping Procedures:
For Single Lamp ECG: Change the defective lamp and ECG will resume the operation immediately.
For Multi Lamp ECG: Replace all of these lamps and ensure that the MASTER Lamp is the last lamp inserted. Rotate the MASTER Lamp to
reset the ECG if necessary.

Page 2 of 2

Você também pode gostar