Você está na página 1de 8

FROM

DESIGN REALITY
TO

Dallas TX

A R C H I T E C T U R A L F L AT, B E N T A N D S E C U R I T Y G L A S S FA B R I C AT O R S

Ledyard CT

Ft. Lauderdale FL

Cleveland OH

LAMINATED

Annealed, Heat Strengthened or Tempered.


Chemically Strengthened

glass

Maximum Sizes up to 90 x 137 Depending


on Glass Options
Clear, White or Colored PVB and
DuPont SentryGlas Interlayers and Spallshield

Rockefeller Center NY NY
Pittsburgh PA

Hurricane Interlayers Certified to Applicable Codes


Laminated Insulating glass products available in
sizes up to 84 x 137 ASTM 2190 Certified.
Certified Laminator of PPG Solarban 60 & 70
Laminated Pattern Glass
Meets Safety Codes; ANSI Z97, ANSI Z96,
and CPSC 16 CFR 1201 CAT I or II
Fabricated according to ASTM 1172

Mount Pleasant SC

TEMPERED, HEAT &


CHEMICALLY STRENGTHENED
Heat Treated Glass available in thicknesses from
1/8 to 3/4

glass
Philadelphia PA

Maximum Size 84 x 180


Fabricated according to ASTM C1048, Meets
CPSC 16 CFR 1201 CAT I & II as well as ANSI Z97.1
Heat Soak Option Available
Miami Intl. Aiport, FL

Chemically Strenghthened Glass Fabricated accoding


to ASTM C1422.
Maximum Size 46 x 80

George Bush Intl. Aiport, Houston TX

INSULATING

glass

High Performance IGUS available for all Security Glass


Maximum Size 84 x 130
Fabricated according to ASTM C2190
Certified Guardian Select SunGuard Fabricator

BENT

glass

Annealed Laminated or Insulating up to


96 x 170, Contact us for Details
Bent Reflective and Low E Glass

Birmingham AL

Compound Bends

Palm Beach FL

Fabricated to ASTM C 1464

Virginia Beach VA

SILK SCREEN PRINTED DESIGN


Custom and Standard Patterns

glass
Richmond Virginia

Wide Array of Fired on Ceramic Frit Colors


Standard Sizes up to 80 x 130
Larger Sizes can be Reviewed Upon Request
Available in Monolithic, Heat Strengthened,
Tempered, Laminated or Insulating Units
(80 x 130) ASTM E 2190 Certified
Curved Units Available, Call for Details

Ohio

051012

NY City Housing

GLASS CLAD POLYCARBONATE

FORCED ENTRY
& DETENTION

Standard Sizes for Polycarbonate Laminates


up to 60 x 120 or 72 x 96
Larger Sizes Available Upon Request

glass

Insulating Units Available


ASTM E 2190 Certified
Strengthened Glass Surfaces for
Maximum Scratch & Chemical Resistance
High Impact Polycarbonate Core,
Single or Multi-Layered
to Meet Desired Protection Level
Urethane Interlayers Create
High-Strength Bond
Detention Center

Glass Clad Polycarbonate Products


Product
Number
DGCP437
DGCP562
DGCP687
DGCP750
DGCP812
DGCP937
DGCP1000
DGCP1250

Forced Entry
Protection
ASTM 1233-95
Class 1 Forced Entry
ASTM F1915-05 Grade 4
10 Min. Forced Entry

ASTM F1915-05 Grade 3


20 Min. Forced Entry

ASTM F1915-05 Grade 2


40 Min. Forced Entry

ASTM F1915-05 Grade 3


20 Min. Forced Entry

ASTM F1915-05 Grade 2


40 Min. Forced Entry

ASTM F1915-05 Grade 1


60 Min. Forced Entry

ASTM F1915-05 Grade 1


60 Min. Forced Entry

Ballistic
Protection
N/A
HPW-TP-0500.03
Level A Ballistics .38 Special
Modified (Spall No Penetration)
HPW-TP-0500.03
Level B Ballistics 9mm
Modified (Spall No Penetration)
HPW-TP-0500.03
Level B Ballistics 9mm
Modified (Spall No Penetration)
HPW-TP-0500.03
Level B Ballistics 9mm
Modified (Spall No Penetration)
HPW-TP-0500.03
Level B Ballistics .357 Magnum
Modified (Spall No Penetration)
HPW-TP-0500.03
Level B Ballistics .357 Magnum
Modified (Spall No Penetration)
HPW-TP-0500.03
Level C Ballistics .44 Magnum
Modified (Spall No Penetration)

Thickness Tolerance Weight Visible Light Winter


Nominal Min Max lbs/sq ft Transmittance U-Value

Solar
Heat Gain
Coefficient

Shading
Coefficient

.458

.436 .508

4.46

82.2%

.868

.720

.832

.560

.528 .620

5.09

77.9%

.806

.709

.819

.715

.658 .791

6.06

75.4%

.746

.700

.809

.703

.647 .778

5.97

73.4%

.741

.696

.804

.744

.683 .823

6.21

73.0%

.730

.693

.800

.846

.775 .935

6.85

69.2%

.685

.686

.792

.960

.879 1.061

7.57

67.3%

.650

.682

.787

1.221

1.123 1.326

10.71

63.8%

.634

.641

.740

Size Restrictions:, Ask for Details

LAMINATED
POLYCARBONATE

Mar-Resistant Polycarbonate Surfaces


Maximum Impact Resistance with no
Worry of Glass Breakage
High Impact Polycarbonate Core,
Single or Multi-Layered
to Meet Desired Protection Level

All Polycarbonate Products


Product
Number
DLP375
DLP500
DLP750

Forced Entry
Protection

Ballistic
Protection

ASTM F1915-05 Grade 3 Level AHPW-TP-0500.03


Ballistics .38 Special
20 Min. Forced Entry

ASTM F1915-05 Grade 2


40 Min. Forced Entry

ASTM F1915-05 Grade 1


60 Min. Forced Entry

DLP1000

HPWTP0500.03 Level 4

DLP1250

HPWTP0500.03 Level 4
Thru Step 44

No Spall
HPW-TP-0500.03
Level A Ballistics .38 Special
No Spall
HPW-TP-0500.03
Level B Ballistics 9mm
No Spall
HPW-TP-0500.03
Level B Ballistics .357 Magnum
Modified, No Spall
UL 752 Level 3 Ballistics
.44 Magnum, No Spall

Urethane Interlayers Create


High-Strength Bond

Thickness Tolerance Weight Visible Light Winter


Nominal Min Max lbs/sq ft Transmittance U-Value

Solar
Heat Gain
Coefficient

Shading
Coefficient

.399

.341 .418

2.35

78.6%

.831

.794

.915

.506

.455 .557

3.13

72.2%

.762

.770

.888

.786

.707 .865

4.88

70.0%

.661

.763

.880

1.061

.956 1.169

6.56

62.6%

.585

.741

.854

1.311

1.180 1.443

8.14

60.7%

.524

.736

.848

Size Restrictions: Ask for Details

FIRE-PROTECTION-RATED
SECURITY GLAZING

Wired Glass-Clad
Polycarbonate Laminates
Dlubak Corporations Wired Glass-Clad Polycarbonates are intended for
installation in fire windows, fire doors, and fire door frames with transoms
and/or sidelights that are provided with suitable glazing frame members.
The wired-glass surfaces, bonded to a polycarbonate core create a product
that not only resists extreme impact from physical and ballistic attack but also provides UL Classified Fire-RatedProtection. These are the ultimate glazing product for detention or correctional facilities and other applications that
require protection against physical attack and fire.

UL Fire Tested

Wired Glass Plates on Surfaces for


Fire Protection (Square or Diamond)

Our Fire-Protection-Rated products are available in several


standard makeups that offer a full range of protection against
physical attack and ballistics as well as 20, 45 and 90 min fire
ratings. The chart below shows our standard products along with
testing and technical data. Please contact us at 800-336-0562
for additional technical information or questions. You can also
visit our website at www.dlubakglass.com

High Impact Polycarbonate Core,


Single or Multi-Layered
to Meet Desired Security Protection

Urethane Interlayers
Create High-Strength Bond

Fire-Protection-Rated Security Glazing Products


Product
Number

Forced Entry
Protection
ASTM 1233-95
Class 1 Forced Entry
ASTM F1915-05 Grade 4

DFR437WW
DFR562WW

10 Min. Forced Entry

F1915-05 Grade 3
DFR687WW ASTM
20 Min. Forced Entry

F1915-05 Grade 2
DFR750WW ASTM
40 Min. Forced Entry
ASTM F1915-05 Grade 3

DFR812WW

20 Min. Forced Entry

ASTM F1915-05 Grade 2

DFR937WW

40 Min. Forced Entry

DFR1000WW
DFR1250WW

ASTM F1915-05 Grade 1


60 Min. Forced Entry

ASTM F1915-05 Grade 1


60 Min. Forced Entry

Ballistic
Protection
N/A
HPW-TP-0500.03
Level A Ballistics .38 Special
Modified (Spall No Penetration)
HPW-TP-0500.03
Level B Ballistics 9mm
Modified (Spall No Penetration)
HPW-TP-0500.03
Level B Ballistics 9mm
Modified (Spall No Penetration)
HPW-TP-0500.03
Level B Ballistics 9mm
Modified (Spall No Penetration)
HPW-TP-0500.03
Level B Ballistics .357 Magnum
Modified (Spall No Penetration)
HPW-TP-0500.03
Level B Ballistics .357 Magnum
Modified (Spall No Penetration)
HPW-TP-0500.03
Level C Ballistics .44 Magnum
Modified (Spall No Penetration)

Thickness Tolerance Weight Visible Light


Nominal Min Max lbs/sq ft Transmittance
.718

.696 .834

7.88

80.0%

.820

.788 .946

8.52

75.8%

.975

.928 1.117

9.48

73.3%

.963

.917 1.104

9.39

71.4%

1.004

.953 1.149

9.63

71.1%

1.106

1.045 1.261

10.27

67.3%

1.22

1.149 1.387

10.99

65.5%

1.261

1.185 1.432

11.24

63.8%

UL Classified
Fire-Protection-Rated Gazing
Material, tested in accordance with:
ANSI/UL9 Standard for Fire Tests
of Window Assemblies
ANSI/UL10B Standard for Fire Tests
of Door Assemblies
ANSI/UL10C Standard for Positive
Pressure Fire Tests of Door

Also carries UL Canadian


Classification for:
All of the products above are Fire-Protection- Rated for the following applications. Please review the chart
below for size and framing restrictions as well as building codes for each rating and application.
Maximum Exposed (Visual Opening)
Building Code
Minimum Depth of
Rating
Application
Markings
Glazing Pocket
Height
Width
Total Area
20 Min

Window Frame,
Transome Frame, Sidelite

1764 sq in

42

42

1 (3/4 Bite)

D-NH-NT-20

20 Min

Door With Light Kit

1344 sq in

32

42

1-1/4 (1 Bite)

D-NH-NT-20

45 Min

Window Frame,
Transome Frame, Sidelite

1764 sq in

42

42

1-1/4 (1 Bite)

D-H-NT-45

45 Min

Door With Light Kit

1344 sq in

32

42

1-1/4 (1 Bite)

D-H-NT-45

90 Min

Door With Light Kit

100 sq in

10

33

1-1/4 (1 Bite)

D-H-NT-90

Due to the specialized nature of this product, detailed installation instructions will be provided with each assembly. This product is intended
for interior installations only, as wire glass breakage can occur due to thermal stress.

CAN4-S104-10 Canadian National


Standard Method for Fire Tests of Doors
CAN4-S106-80 Canadian National
Standard Method for Fire Tests of
Window Assemblies.

051012

BULLET RESISTANT

glass
UL 752 Listed, NIJ & EN No-Spall Ballistic
Protection, Handguns to High-Powered Rifles
All Glass & Thinner and Lighter
Glass/Polycarbonate Makeups Available
Insulating Units Available
(ASTM E 2190 Certified)
Custom Designs & Low Spall Units
Available for Government, Military and
Commercial Applications

Drive Through Windows


E.F. Bavis

UL 752 Listed Bullet Resistant Laminates


Product
Number
DBG01

Protection
Level
Level 1

(All Glass)

9mm Handgun FMJ Lead Core, 3 shots

DBP01

Level 1

DBP03

Level 3

DBP04

Level 4

DBP05

Level 5

DBP08

Level 8

(Glass / Polycarbonate) 9mm Handgun FMJ Lead Core, 3 shots


(Glass / Polycarbonate) .44 Mag SWC Gas Checked, 3 shots
(Glass / Polycarbonate) 30-06 Riffle Lead Core Soft Point, 1 shot
(Glass / Polycarbonate) 7.62 mm Rifle Lead Core FMJ, 1 shot
(Glass / Polycarbonate) 7.62 mm Rifle Lead Core FMJ, 5 shots

Thickness Tolerance
Weight Visible Light Winter
Nominal Minimum Maximum lbs/sq ft Transmittance U-Value

Solar
Heat Gain
Coefficient

Shading
Coefficient

1.29

1.209

1.381

16.29

77.1%

.850

.577

.669

.778

.713

.823

8.82

79.0%

.870

.655

.758

1.078

.998

1.145

12.54

76.0%

.828

.610

.706

1.238

1.134

1.307

14.64

74.5%

.814

.591

.685

74.5%

.814

.591

.685

56.1%

.592

.525

.607

1.238

1.134

1.307

14.64

2.350

2.211

2.552

26.30

Size Restrictions: Minimum 12 x 12 , Maximum; Ask for Details

NIJ 0108.01 and EN 1063 No Spall Bullet Resistant Laminates


NIJ Level 2
.357 Mag JSP, 5 shots
9mm FMJ, 5Shots
EN Class Br4
.44 Mag, FCJ Flat Nose
Soft Core, 3 Shots
NIJ Level 3A
DBR32NS
.44 Mag Handgun Lead
(Glass / Polycarbonate)
SWC Gas Checked, 5 shots
9mm FMJ, 5 Shots
EN Class Br5
5.56 x 45 NATO, Type SS109
(Steel Penetrator), 3 Shots
NIJ Level 3
DBR34NS

DBR20NS

.828

.761

.882

8.87

79.3%

.842

.657

.759

1.338

1.216

1.409

15.36

74.2%

.784

.588

.681

1.338

1.248

1.432

15.96

73.1%

.801

.577

.668

1.718

1.562

1.807

19.90

70.6%

.734

.558

.646

2.288

2.135

2.449

27.40

65.3%

.690

.524

.607

2.848

2.703

3.093

34.54

59.9%

.642

.505

.584

(Glass / Polycarbonate)

(Glass / Polycarbonate) 7.62 x 51 M80 Ball FMJ Rifle, 5 shots

DBR40NS
(Glass / Polycarbonate)

NIJ Level 3

7.62 x 51 M80 Ball FMJ Rifle, 5 shots

EN Class Br6

7.62 x 51 M80 Ball FSJ Rifle, 3 Shots

DBR54NS

(Glass / Polycarbonate)

DBR72NS
(Glass / Polycarbonate)

NIJ Level 4
30-06 AP Rifle, 1 shot
EN Class BR7

7.62 x 51 NATO Rifle FCJ Steel Core,


3 shots

Size Restrictions: Minimum; 19-3/4 x 19-3/4 , Maximum; Ask for Details

No matter which product you chose there are several additional options available such as : Tinted Glass, Reflective Glass, One
Way Mirror, Frosted Glass, Colored Interlayers, Wire Glass, Self-Cleaning Glass, Insulating Units With Low E Coatings, Holes and
Pass Thru, Custom Shapes

Up Armored HMMWV

TRANSPARENT ARMOR
RG 31 MRAP

glass
Transparent Armor for Military Applications
Built to ATPD 2352 Specifications
Current Solutions for 1b, 2b, 3a
Heated Windscreens Available
Rock Strike Capability
High Volume Production Capacity to Handle
Thousands of Parts Per Month
Custom Design and Solutions

RG 33 MRAP

Gunner Protection Kit Glass

BLAST RESISTANT

glass

Tempered Glass Laminates


(Cost effective & Maximum Durability)
DuPont SentryGlas & Spall Shield
(Duponts Ionoplast Interlayer Technology)
Glass/Polycarbonate Laminates
Insulating Units Available
(ASTM E 2190 Certified)
Custom Designs Available for Government,
Military and Commercial Applications
FBI Birmingham, Al

Quito, Ecuador NEC

Kathmandu, Nepal USAID Annex

Air Force Research Lab, Tyndall

BLAST DESIGN: It is important to note that a blast resistant window operates as a system. It involves not only the glass itself, but also the
framing system, anchoring system and even the structure of the building. A frame that is not designed for blast or that is not anchored properly
may not hold the glazing during a blast situation causing unnecessary failure and possible injury. A qualified blast engineer should be
consulted for the design of each project.

051012

FROM

Make Dlubak Corporation your choice for


Curved Glass & Extrusions / Specialty Flat
Laminated and Insulating Glass Products

DESIGN REALITY
TO

www.dlubakglass.com

Blast Resistant
Armored Vehicles, Courthouses, Embassy, etc

Curved Glass
Display Case
Jewelry, Refrigeration, Sneeze Guard, etc

Edgework, Holes (NC machined) / Notches, Water-Jet Cutting


Graphics & Design
Logos, Sandblasting, etc

Hurricane
DuPont Butacite PVB, SentyGlas and Spallshield
Solutia Saflex PVB, Saflex HP, Vanceva Storm
Hyzod Polycarbonate Sheet

Insulating / Bystronic Line (ASTM E 2190 Certified)


High Performance, Screen Printed / Spandrel, Security / Ballistic

Laminated Glass / Interlayer


Butacite by DuPont - .015, .030, .060, .090 interlayer
SentyGlas by DuPont - .035, .060, .090, .100 interlayer
Spallshield by DuPont
Saflex by Solutia - .015, .030, .060, .090 interlayer
Polyurethane interlayers
Colored PVB Interlayers by DuPont, Solutia (Vanceva) and Trosifol

Security / Bullet Resistant


All Glass, Glass Clad Polycarbonate and all Polycarbonate Laminates
UL 752 Listed Ballistic Levels I, III, IV, V, VIII
NIJ Ballistic Levels II, III, IIIA, IV
EN Ballistic Levels BR4, BR5, BR6, Br7
UL 9,10B &10C Classified Fire-Protection-Rated Gazing
UL CAN4-S104-10 & CAN4-S106-80 Classified Fire-Protection-Rated Gazing
Transparent Armor for Military Vehicles tested to the ATPD2352 Standard

Screen Printing
Dots, Holes, Stripes, Custom Patterns and Colors

Spandrel
Standard and Custom

Heat and Chemically Tempered Glass


1/8 to 3/4 thickness
For Additional Information:
Specifications and Applications
for our Quality Products.
Technical Assistance or
Samples of our Products
for your Project needs.
Area Sales Representatives
available upon request.
051012

Contact Us At:
Dlubak Corporation
520 Chestnut Street
P.O. Box 510
Blairsville, PA 15717
Phone: 800-336-0562
Fax: 724-459-0866
www.dlubakglass.com