Você está na página 1de 298

Indoor unit

0CVP0-02A (Replaces:0CVP0-01D)

LG Airconditioners Product Data

Indoor unit
(R410A)

Introduction
General Information
Indoor Units

Introduction
1. Preface
R410A Model
is the most favored choice when there is a need for precise air conditioning of relatively big
projects extending from Multi-Room structure to big commercial places. We have a big line up, that offers wider
flexibility of model selection.
Equipped with inverter technology and long piping installation, the product matches well if one talk about optimum power consumption in high rise buildings. Add on capacity feature makes it easy to upgrade the existing
capacity at any time.
With the growing concern about environment preservation,
comes with R410A refrigerant which
is environment friendly and thus our
system is a high technology and environment friendly product.

Unique refrigerant flow and electronic circuit control gives this system an unique capability to work in
extreme/abnormal working conditions making our customer feel great about their decision of selecting
LG
as their first choice.
This publication provides a detailed and in depth information about the design and installation of
.
We hope that with this information you would become an expert of your

system.

Air-Conditioning Company

2. Step by Step
(1)

(2)

System Selection Process

Calculate or obtain the maximum heat load for the area(s) to be air conditioned

Decide the indoor unit specifications


Decide the outdoor unit specifications
Capacity coefficient factor
Decide the air velocity and temperature distributions

(3)

(4)

Selection of refrigerant pipe joints and headers

Selection of the control system


Control wiring method
Description of devices

(5)

Electrical wiring
Electric characteristics
Field wiring

Caution

1. Air conditioners should not be installed in areas where corrosive gas such as acid gas
or alkaline gas is produced.
2. If the outdoor unit is installed close to the sea shore, direct exposure to the sea breeze
should be avoided and choose an outdoor unit with anti-corrosion treatment.

Indoor unit
General Information
1. Model Names
2. External Appearance
3. Nomenclature
4. Indoor Unit Capacity Index

Indoor unit

General information

1. Model Names
Category

Chassis
Name
SE

Wall Mounted
(General)

Capacity(Btu/h(kW))
5k
7k
(1.6) (2.2)

9k
(2.8)

12k
(3.6)

15k
(4.5)

18k
(5.6)

Mirror
ART COOL

ARNU18 ARNU24
GS5*2 GS5*2
ARNU07 ARNU09 ARNU12 ARNU15
GSE*2 GSE*2 GSE*2 GSE*2
ARNU18 ARNU24
GS8*2 GS8*2

S8
Gallery

SF

1 Way

TJ

2 Way

TL
TR

Ceiling

ARNU07 ARNU09 ARNU12


GSF*2 GSF*2 GSF*2
ARNU07 ARNU09 ARNU12
GTJ*2 GTJ*2 GTJ*2
ARNU18 ARNU24
GTL*2 GTL*2
ARNU05 ARNU07 ARNU09 ARNU12
GTR*2 GTR*2 GTR*2 GTR*2
ARNU15 ARNU18
GTQ*2 GTQ*2

TQ

Cassette
4 Way

28k 36k 42k


48k
76k 96k
(8.2) (10.6) (12.3) (14.1) (22.4) (28)

ARNU07 ARNU09 ARNU12 ARNU15


GSE*2 GSE*2 GSE*2 GSE*2

S5
SE

24k
(7.1)

ARNU24 ARNU28
GTP*2 GTP*2

TP

ARNU36
GTN*2

TN

ARNU42 ARNU48
GTM*2 GTM*2

TM
BH
High
Static
Ceiling
Concealed
Duct

ARNU07 ARNU09 ARNU12 ARNU15 ARNU18 ARNU24


GBHA2 GBHA2 GBHA2 GBHA2 GBHA2 GBHA2
ARNU28 ARNU36 ARNU42
GBGA2 GBGA2 GBGA2

BG

ARNU48
GBRA2

BR

URNU76 URNU96
GB8A2 GB8A2

B8
B1
Low Static

ARNU07 ARNU09 ARNU12 ARNU15


GB1G2 GB1G2 GB1G2 GB1G2
ARNU18 ARNU24
GB2G2 GB2G2

B2
B3
Built In

ARNU07 ARNU09 ARNU12 ARNU15


GB3G2 GB3G2 GB3G2 GB3G2
ARNU18 ARNU24
GB4G2 GB4G2

B4
Ceiling & Floor

VE

Ceiling Suspended

VJ
CE

With Case

ARNU09 ARNU12
GVEA2 GVEA2
ARNU18 ARNU24
GVJA2 GVJA2
ARNU07 ARNU09 ARNU12 ARNU15
GCEA2 GCEA2 GCEA2 GCEA2
ARNU18 ARNU24
GCFA2 GCFA2

CF

Floor
Standing
Without
Case

CE
CF

ARNU07 ARNU09 ARNU12 ARNU15


GCEU2 GCEU2 GCEU2 GCEU2
ARNU18 ARNU24
GCFU2 GCFU2

*ART COOL- SE/S8( * R:Mirror, V:Silver, B : Blue), SF(* E:Red, V:Silver, G:Gold , 1: Kiss (Photo changeable))
*Wall Mounted- A: Basic, L:Plasma
*Ceiling Cassette- A: Basic, C:Plasma

General information

Indoor unit

2. External Appearance
Ceiling Cassette- 1Way

Ceiling Cassette -2Way

ARNU07GTJ*2
ARNU09GTJ*2
ARNU12GTJ*2

ARNU18GTL*2
ARNU24GTL*2

* A:Basic, C:Plasma

* A:Basic, C:Plasma

Ceiling Cassette- 4Way

Ceiling Concealed Duct - High Static

ARNU05GTR*2
ARNU07GTR*2
ARNU09GTR*2
ARNU12GTR*2
ARNU15GTQ*2
ARNU18GTQ*2

ARNU07GBHA2
ARNU09GBHA2
ARNU12GBHA2
ARNU15GBHA2
ARNU18GBHA2
ARNU24GBHA2
ARNU28GBGA2

ARNU24GTP*2
ARNU28GTP*2
ARNU36GTN*2
ARNU42GTM*2
ARNU48GTM*2

ARNU36GBGA2
ARNU42GBGA2
ARNU48GBRA2
URNU76GB8A2
URNU96GB8A2

* A:Basic, C:Plasma

Ceiling Concealed Duct - Low Static

Wall Mounted

ARNU07GB1G2 ARNU15GB1G2
ARNU09GB1G2 ARNU18GB2G2
ARNU12GB1G2 ARNU24GB2G2

ARNU07GSE*2
ARNU09GSE*2
ARNU12GSE*2

ARNU15GSE*2
ARNU18GS5*2
ARNU24GS5*2
* A:Basic, L:Plasma

Ceiling Concealed Duct Built-in

ART COOL Gallery

ARNU07GB3G2
ARNU09GB3G2
ARNU12GB3G2

ARNU07GSF*2
ARNU09GSF*2
ARNU12GSF*2

ARNU15GB3G2
ARNU18GB4G2
ARNU24GB4G2

* E:Red V:Silver
G:Gold 1: Kiss (Photo changeable)

ART COOL Mirror


ARNU07GSE*2
ARNU09GSE*2
ARNU12GSE*2
ARNU15GSE*2
ARNU18GS8*2
ARNU24GS8*2

* R:Mirror
V:Silver
B:Blue

Ceiling & Floor


ARNU09GVEA2
ARNU12GVEA2

Ceiling Suspended
ARNU18GVJA2
ARNU24GVJA2

Floor Standing
With case
ARNU07GCEA2
ARNU09GCEA2
ARNU12GCEA2
ARNU15GCEA2
ARNU18GCFA2
ARNU24GCFA2

Without case
ARNU07GCEU2
ARNU09GCEU2
ARNU12GCEU2
ARNU15GCEU2
ARNU18GCFU2
ARNU24GCFU2

Indoor unit

General information

3. Nomenclature
ARN

07

TJ

2
Serial Number
Combinations of functions
A:Basic function
L:Neo Plasma(Wall Mounted)
C:Plasma(Ceiling Cassette)
G: Low Static
U : Floor Standing without Case
ART COOL Type Panel Color
SE/S8 - R:Mirror V:Silver B:Blue
SF - E:Red V:Silver G:Gold 1: Kiss (Photo changeable)
Chassis Name
Electrical Ratings
2: 1, 220V, 60Hz
6:1, 220 ~ 240V, 50Hz
G:1, 220 ~ 240V, 50Hz / 220V 60Hz
Total Cooling Capacity in Btu/h
EX) 5,000 Btu/h'05' 18,000 Btu/h'18'
Combination of Inverter Type and
Cooling Only or Heat Pump
N: AC Inverter and H/P V: AC Inverter and C/O
U: DC Inverter and H/P and C/O
System with
Indoor Unit using R410A
LGETA:U Ex) URN

General information

Indoor unit

4. Indoor Unit Capacity Index


INDOOR UNIT CAPACITY INDEX
Unit Capacity
(Btu/h)

5k

7k

9k

12k

15k

18k

24k

28k

36k

42k

48k

76k

96k

Capacity
Index

1.6

2.2

2.8

3.6

4.5

5.6

7.1

8.2

10.6

12.3

14.1

22.4

28

Capacity Index is same as the capacity(kW).

Indoor unit

General information

Indoor unit
Indoor Units

Ceiling Cassette 2-Way


Ceiling Cassette 4-way
Ceiling Concealed Duct(High Static)
Ceiling Concealed Duct(Low Static)
Ceiling Concealed Duct(Built in)
Wall Mounted
ART COOL Mirror
ART COOL Gallery
Ceiling & Floor/Ceiling Suspended
Floor Standing

Indoor unit

Cassette 1-way

Ceiling Cassette 1-Way

Ceiling Cassette 1-Way

1. List of functions
2. Specifications
3. Dimensions
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. Air Velocity and Temperature Distribution
8. Electric Characteristics
9. Sound Levels
10. Installation
11. Accessories

Indoor unit

Ceiling Cassette 1-way

1. List of functions
Category

Air flow

Installation

Reliability

Convenience

Individual
control

Special
function kit

Air supply outlet


Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Wide wired remote controller
Deluxe wired remote controller
Simple wired remote controller
Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
Zone control
CTIE
Electro thermostat

ARNU07GTJ*2, ARNU09GTJ*2, ARNU12GTJ*2


1
Auto
O
4/5/4
X
O
O
X
Option
O
O
O
X
O
O
O
O
O(Heat recovery)
X
O(Heat pump or Cooling only)
O
O
O
O
O
O
O
O
Accessory
Accessory
Accessory
Accessory
X
Accessory
-

Cassette 1-way

Air purifying

Function

O : Applied
X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.
* Some functions can be limited by remote controller.

Ceiling Cassette 1-way

Indoor unit

1-1

2. Specifications

Cassette 1-way

* Model Name
A:Basic, C:Plasma
Type
Model
Cooling Capacity

Heating Capacity

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h

Casing
Body
Dimensions (WxDxH)
Front Panel
Coil

Fan

Rows x Columns x FPI


Face Area
Type
Motor Output x Number
Running Current
Air Flow Rate(H/M/L)

mm
inch
mm
inch
m2
W
A
CMM
cfm

Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Safety Device
Liquid Side
mm(inch)
Pipe Connections Gas Side
mm(inch)
Drain Pipe(Internal Dia.)
mm
Net Weight
Body
kg(lbs)
Noise Level(Sound Press, 1.5m, H/M/L) dB(A)3
Power Supply
Refrigerant Control
Power cable
Transmission cable
Panel Color
Panel Name(Accessory)

, V, Hz

1Way Ceiling Cassette


ARNU07GTJ*2
ARNU09GTJ*2
ARNU12GTJ*2
2.2
2.8
3.6
1,900
2,400
3,100
7,500
9,600
12,300
2.5
3.2
4.0
2,200
2,800
3,400
8,500
10,900
13,600
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
860x410x138
860x410x138
860x410x138
33.8x16.1x5.4
33.8x16.1x5.4
33.8x16.1x5.4
1,070x480x20
1,070x480x20
1,070x480x20
42.1x18.9x0.8
42.1x18.9x0.8
42.1x18.9x0.8
2x9x21
2x9x21
2x9x21
0.13
0.13
0.13
Cross Flow Fan
Cross Flow Fan
Cross Flow Fan
20.0
20.0
20.0
0.20
0.20
0.20
7.5/6.5/6
7.5/6.5/6
8/7/6
265/229/212
265/229/212
283/247/212
Direct
Direct
Direct
BLDC
BLDC
BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene
Foamed polystrene
Foamed polystrene
Fuse
Fuse
Fuse
6.35(1/4)
6.35(1/4)
6.35(1/4)
12.7(1/2)
12.7(1/2)
12.7(1/2)
25.0
25.0
25.0
11.5(25.4)
11.5(25.4)
11.5(25.4)
40/38/37
40/38/37
41/39/37
1, 220 ~ 240, 50
1, 220 ~ 240, 50
1, 220 ~ 240, 50
1, 220, 60
1, 220, 60
1, 220, 60
EEV
EEV
EEV
CV1.5 x 3C
CV1.5 x 3C
CV1.5 x 3C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
Morning fog
Morning fog
Morning fog
PT-HJ*

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are Net Capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve

1-2

Indoor unit

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

Ceiling Cassette 1-way

83
138

410
344.4

32.8

198.8

19.1 16.5

131

16.4

Indoor unit
939

1070

Branch Duct Connection

923

961.2
860

410
1

30
36
50
83

Gas pipe connection


Air suction grill
Air discharge grill

3
4

Unit size(7k, 9k, 12k):12.7

Unit size(7k, 9k, 12k):6.35

Descripition

(unit : mm)

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

CHASSIS CODE: TJ

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Note

Liquid pipe connection

Name

Number

ARNU07GTJ*2
ARNU09GTJ*2
ARNU12GTJ*2

Cassette 1-way

Ceiling Cassette 1-way

480

Ceiling Cassette 1-way

3. Dimensions

110

1-3

173
151
100
56

242.5

Cassette 1-way

4. Piping Diagrams

Heat Exchanger

EEV

Filter

:Cooling
:Heating

Th2

Th3
C.F.F.

Filter
Th1

lndoor unit

Refrigerant pipe connection port diameter


[Unit: mm(inch)]

Model

Gas

Liquid

12.7(1/2)

6.35(1/4)

ARNU07GTJ*2
ARNU09GTJ*2
ARNU12GTJ*2

1-4

LOC.

Description

Th1

Room thermistor

Th2

Pipe in thermistor

Th3

Pipe out thermistor

Indoor unit

Ceiling Cassette 1-way

5. Wiring Diagrams
TJ Chassis

Cassette 1-way

CONNECTOR NUMBER
CN-POWER
CN-MOTOR1
CN-D/PUMP
CN-485
CN-DISP
CN-EEV
CN-VANE2
CN-FLOAT
CN-PIPE/IN
CN-PIPE/OUT
CN-ROOM
CN-REMO
CN-CC
CN-AIRC

LOCATION POINT
AC Power supply
Fan motor output
Drain pump output
Communication
Display
EEV Output
Step motor
Float switch input
Suction pipe sensor
Discharge pipe sensor
Room sensor
Remote controller
Dry contact
Air clean

Dip Switch Setting


SW3
GROUP

Off
Master

On
Slave

SW4

DRY CONTACT

Variable

Auto

SW5

EXTRA 1

Off

On

FUNCTION
AC Power line input for indoor controller
Motor output of BLDC
AC output for drain pump
Connection between indoor and outdoor
Display of indoor status
EEV Control output
Step motor output
Float switch sensing
Pipe in thermistor
Pipe out thermistor
Room air thermistor
Remote control line
Dry contact line
Air cleaner control
Remarks
Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

Ceiling Cassette 1-way

Indoor unit

1-5

6. Capacity Tables

Cassette 1-way

6.1 Cooling Capacity

Cooling capacity

20
14
TC SHC
kW kW

23
16
TC SHC
kW kW

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

2.2

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8

1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6

2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.2

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.5

2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.5
2.5
2.5
2.4
2.4
2.3
2.3

1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.6
1.6
1.6
1.5
1.5
1.5
1.5

2.9
2.9
2.8
2.8
2.7
2.7
2.7
2.6
2.6
2.6
2.5
2.5
2.5
2.4
2.4
2.3

1.7
1.6
1.6
1.6
1.6
1.6
1.5
1.5
1.5
1.5
1.5
1.4
1.4
1.4
1.4
1.4

2.8

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6

2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8

2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
2.9
2.9

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.3
3.2
3.2
3.1
3.1
3.0
3.0
2.9

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.0
2.0
2.0
1.9
1.9
1.9

3.7
3.6
3.6
3.5
3.5
3.4
3.4
3.4
3.3
3.3
3.2
3.2
3.1
3.1
3.0
3.0

2.1
2.1
2.1
2.0
2.0
2.0
2.0
1.9
1.9
1.9
1.9
1.8
1.8
1.8
1.8
1.7

3.6

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1

2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9

2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6

3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6

2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6

3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.7
3.7

2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.6
2.6

4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.2
4.1
4.1
4.0
4.0
3.9
3.8
3.7

2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.7
2.7
2.6
2.6
2.5
2.5
2.4

4.7
4.7
4.6
4.6
4.5
4.4
4.4
4.3
4.3
4.2
4.2
4.1
4.0
4.0
3.9
3.8

2.8
2.7
2.7
2.7
2.6
2.6
2.6
2.5
2.5
2.5
2.4
2.4
2.4
2.3
2.3
2.2

Capacity
Index

Outdoor
air temp.
(DB, C)

Notes:
TC: Total Capacity(kW)

1-6

30
22
TC SHC
kW
kW

32
24
TC SHC
kW kW

SHC: Sensible Heat Capacity(kW)

Indoor unit

Ceiling Cassette 1-way

6.2 Heating Capacity


Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

2.8

3.6

Indoor air temp. (DB, C)


16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

kW

kW

kW

kW

kW

kW

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.3
2.4
2.5
2.6
2.8
2.8
2.9
2.9
2.9
2.9
2.9

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.3
2.4
2.5
2.6
2.7
2.7
2.7
2.7
2.7
2.7
2.7

1.7
1.7
1.8
1.7
1.8
1.9
1.9
2.0
2.0
2.1
2.2
2.3
2.4
2.5
2.5
2.5
2.5
2.5
2.5

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.2
2.3
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.2
2.3
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

1.7
1.7
1.8
1.9
2.0
2.1
2.1
2.1
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7
-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

2.1
2.2
2.3
2.5
2.6
2.7
2.8
2.8
2.9
3.0
3.2
3.4
3.6
3.6
3.7
3.7
3.7
3.7
3.7
2.7
2.8
2.9
3.1
3.2
3.4
3.4
3.5
3.6
3.8
4.0
4.2
4.4
4.5
4.6
4.6
4.6
4.6
4.6

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.9
3.0
3.2
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
2.7
2.8
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.8
4.0
4.2
4.3
4.3
4.3
4.3
4.3
4.3
4.3

2.1
2.2
2.3
2.2
2.3
2.4
2.5
2.5
2.6
2.7
2.8
3.0
3.1
3.2
3.2
3.2
3.2
3.2
3.2
2.7
2.8
2.9
2.7
2.9
3.0
3.1
3.2
3.3
3.4
3.5
3.7
3.9
4.0
4.0
4.0
4.0
4.0
4.0

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.8
3.0
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
2.6
2.8
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.7
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.8
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
2.6
2.7
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.7
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8

2.1
2.2
2.3
2.4
2.6
2.7
2.7
2.7
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.6
2.7
2.9
3.0
3.2
3.4
3.4
3.4
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5

Cassette 1-way

2.2

Heating capacity

Notes:
TC: Total Capacity(kW)

Ceiling Cassette 1-way

Indoor unit

1-7

7. Air Velocity and Temperature Distribution(Reference Data)

Cassette 1-way

ARNU07GTJ*2
Cooling

Heating

Discharge angle: 45

Discharge angle: 60

Air velocity [m/s]

Air velocity [m/s]


2.7m

2.7m
2.0
1.5

2m

2.0

2m

1.0
1.5

1m

1m
0.5

1.0
0.5
5m

4m

3m

2m

0m
0m

1m

Temperature [C]

5m

4m

3m

2m

0m
0m

1m

Temperature [C]
2.7m

2.7m
33
30

18
2m

20

2m
24

22

21

18

1m

1m

27

24
5m

4m

3m

2m

0m
0m

1m

5m

4m

3m

2m

0m
0m

1m

ARNU09GTJ*2
Heating

Cooling
Discharge angle: 45

Discharge angle: 60
Air velocity [m/s]

Air velocity [m/s]

2.7m

2.7m
2.0
1.5

2m

2m

2.0
1.0
1.5

1m

1m
0.5

1.0
0.5
5m

4m

3m

2m

0m
0m

1m

5m

4m

3m

2m

0m
0m

1m

Temperature [C]

Temperature [C]

2.7m

2.7m
33

18
20

2m

30

21

1m

22

24
4m

3m

2m

1m

0m
0m

5m

4m

1m

27

18

5m

2m

24

3m

2m

1m

0m
0m

Note:
The standard setup height is 2.7m. Shown here is the measurement distribution at the ceiling height of 2.7m

1-8

Indoor unit

Ceiling Cassette 1-way

ARNU12GTJ*2
Cooling

Heating
Discharge angle: 60

Discharge angle: 45

Air velocity [m/s]

Air velocity [m/s]

2.7m

2.7m
2.0

2m
2.0

1m
1.0

1.0

0.5

0.5
4m

3m

Cassette 1-way

1.5
1m

1.5

5m

2m

2m

0m
0m

1m

5m

4m

3m

2m

0m
0m

1m

Temperature [C]

Temperature [C]

2.7m

2.7m
18
20

33
2m

30

21

22

2m

1m

1m
24

27

24
5m

4m

3m

2m

1m

0m
0m

5m

4m

3m

2m

1m

0m
0m

Note:
The standard setup height is 2.7m. Shown here is the measurement distribution at the ceiling height of 2.7m

Ceiling Cassette 1-way

Indoor unit

1-9

8. Electric Characteristics

Cassette 1-way

Units
Model

Type

ARNU07GTJ*2

TJ

ARNU09GTJ*2

TJ

ARNU12GTJ*2

TJ

ARNU07GTJ*2

TJ

ARNU09GTJ*2

TJ

ARNU12GTJ*2

TJ

Power Supply
Hz
50

Volts
220~240

60

220

Voltage Range MCA


Max:264
Min:198
Max:242
Min:198

IFM

Input(W)

MFA

kW

FLA

Cooling Heating

1.29

15

0.02

0.23

40

40

1.29

15

0.02

0.23

40

40

1.29

15

0.02

0.23

40

40

1.29

15

0.02

0.23

40

40

1.29

15

0.02

0.23

40

40

1.29

15

0.02

0.23

40

40

Symbols:
MCA : Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
IFM : Indoor Fan Motor
Note :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA + 1
MFA 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the larger value on the MCA.
5. Instead of fuse, use Circuit Breaker.

1-10

Indoor unit

Ceiling Cassette 1-way

9. Sound Levels
Overall
Notes:
- Sound measured at 1.5m away from the center of the unit.
- Data is valid at free field condition
- Data is valid at nominal operating condition
- Reference accoustic pressure OdB = 20Pa
- Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment is installed.

1.5m

Cassette 1-way

Microphone

Model

ARNU07GTJ*2
ARNU09GTJ*2
ARNU12GTJ*2

Sound Levels dB(A)


M
L

40
40
41

38
38
39

37
37
37

Sound Pressure Level


ARNU07GTJ*2

ARNU09GTJ*2
80

NC-65
60
NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
NC-25

20
Approximate
Hearing
Threshold
63

70

NC-65
60
NC-60

NC-50

250

500

1000 2000 4000 8000

Octave Band Center Frequency (Hz)

Ceiling Cassette 1-way

NC-45

40

NC-40
NC-35

30

NC-30
NC-25

20
Approximate
Hearing
Threshold

NC-15
125

NC-55

50

NC-20

10

80

70

NC-65
60
NC-60

NC-50

250

500

1000

2000

4000

8000

Octave Band Center Frequency (Hz)

Indoor unit

NC-45

40

NC-40
NC-35

30

NC-30
NC-25

20
Approximate
Hearing
Threshold

NC-15
125

NC-55

50

NC-20

10
63

Octave Band Sound Pressure Level (dB re 20Pa )

70

Octave Band Sound Pressure Level (dB re 20Pa )

Octave Band Sound Pressure Level (dB re 20Pa )

80

ARNU12GTJ*2

NC-20
NC-15

10
63

125

250

500

1000

2000

4000

8000

Octave Band Center Frequency (Hz)

1-11

Please read this instruction sheet completely before installing the product.
When the power cord is damaged, replacement work shall be performed by authorized personnel only.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Anti-bacteria filter

Air Outlet

Required Parts
Connecting cable
Pipes: Gas side
Liquid side
Hanging Bolt
(W 3/8 or M10 length 650mm)
Insulated drain hose
Additional Drain hose

TEMP

Remote Controller

Air Intake

Required Tools
Level
Screw driver
Electric drill
Hole core drill
Flaring Tool set
Torque Wrenches
Hexagonal Wrench
Gas-leak detector
Thermometer

10.1 Selection of the best location

1-12

Ceiling board

50 or
more

Ceiling board

50 or
more

30 or less

20 or more

Ceiling

Above 200
300 or less

There should not be any heat source or steam near the


unit.
There should not be any obstacles to the air circulation.
A place where air circulation in the room will be good.
A place where drainage can be easily obtained.
A place where noise prevention is taken into consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the wall,
ceiling, or other obstacles.
The indoor unit must have sufficient maintenance
space.

100
or more

Cassette 1-way

10. Installation

Unit:cm
Floor

Indoor unit

Ceiling Cassette 1-way

10.2 Ceiling opening dimensions and hanging bolt location


The dimensions of the paper pattern for installation
are the same as those of the ceiling opening
dimensions.

1,030 (Ceiling opening)

53

50

344(Hanging bolt)
53

Level gauge

923 (Hanging bolt)


860

Cassette 1-way

Ceiling

450 (Ceiling opening)


410

57

CAUTION
(unit: mm)

This air-conditioner uses a drain pump.


Install the unit horizontally using a level gauge.
During the installation, care should be taken not to
damage electric wires.
Select and mark the position for fixing bolts and piping hole.
Decide the position for fixing bolts slightly tilted to
the drain direction after considering the direction of
drain hose.
Drill the hole for anchor bolt on the wall.

Ceiling board

NOTE:
Avoid the following installation location.
1. Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated.
These may cause heat exchange efficiency reduction, or water drops, drain pump mal-function.
In these cases, take the following actions;
Make sure that ventilation fan is enough to cover all noxious gases from this place.
Ensure enough distance from the cooking room to install the air conditioner in such a place where it may
not suck oily steam.

Air conditioner

Take enough
distance
Use the ventilation fan
for smoke-collecting
hood with sufficient
capacity.
Cooking table

2. Avoid installing air conditioner in such places where cooking oil or iron powder is generated.
3. Avoid places where inflammable gas is generated.
4. Avoid place where noxious gas is generated.
5. Avoid places near high frequency generators.

Ceiling Cassette 1-way

Indoor unit

1-13

Nut
(W3/8 or M10)

55mm

Cassette 1-way

Ceiling
Keep the length of the bolt
from the bracket to 40mm

Hanging bolt
(W3/8 or M10)

Flat washer for M10


(accessory) Ceiling board

Air Conditioner body

Flat washer for M10


(accessory)
Nut
(W3/8 or M10)

Set screw of
paper pattern (4 pieces)

Paper pattern
for installation

Open the ceiling board


along the outer edge of the
paper pattern

Adjust the same height

The following parts are locally purchased.


Hanging Bolt - W 3/8 or M10
Nut
- W 3/8 or M10
Spring Washer - M10
Plate Washer - M10

Ceiling board

CAUTION
Tighten the nut and bolt to prevent the unit
from falling.

10.3 Wiring Connection


Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit
respectively.

Terminal Block Indoor


1(L)

2(N)

SODU

INTERNET DRY1 DRY2 GND 12V

IDU

Outdoor
Unit

INDOOR POWER INPUT

WARNING
Make sure that the screws of the terminal are not loose.

1-14

Indoor unit

Ceiling Cassette 1-way

10.4 Installation of Decoration Panel


Before installing the decoration panel,
always remove the paper template.

The decoration panel has its installation


direction.

Air conditioner unit

Decorative panel
fixing screws
(hexagon M6 screws)
Temporarily fitting
at 2 poles
(Tightening about 10mm)

Piping side

Control box cover


Cover

Plasma filter

Key holes

Louver motor

Decorative panel
fixing screws
(Hexagon M6 screw)

Decorative panel

Push

Ratch
pull

Inlet Grille

CAUTION
Install the decoration panel
otherwise cool air leakage
causes condensation.
Water drops fall.

Correct method

Wrong method
Air conditioner
unit
Cool air leakage
(no good)
Ceiling
board
Decoration panel

Air conditioner
unit
Ceiling
board
Decoration panel

Fit the insulator (this part) and


be careful for cool air leakage

Ceiling Cassette 1-way

Indoor unit

1-15

Cassette 1-way

1. Temporarily fix two decoration panel fixing screws (hexagon M6 screw) on the unit body. (Tighten by amount 10mm in
length.) The fixing screws (hexagon M6 screw) are included in the Indoor unit box.
2. Remove the air inlet grille from the decoration panel. (Remove the hook for the air inlet grille cord.)
3. Hook the decoration panel key hole (
) on the screws fixed in step above, and slide the panel so that the
screws reach the key hole edge.
4. Retighten completely two temporarily fixed screws and other two screws. (Total 4 screws)
5. Connect the louver motor connector and display connector and room temp. thermistor connector.
6. After tightening these screws, install the air inlet grille (including the air filter) and push middle point of inlet grille.
7. Assemble the cover display and the cover.

Drain piping must have down-slope (1/50 to 1/100): be sure


not to provide up-and-down slope to prevent reversal flow.
During drain piping connection, be careful not to exert extra
force on the drain port on the indoor unit.
The outside diameter of the drain connection on the indoor
unit is 32mm.

Upward
routing
not allowed

Pipe clamp
Indoor unit

Maintenance
drain port

Piping material: Polyvinyl chloride pipe 25mm


and pipe fittings
Be sure to install heat insulation on the drain piping.

1/50~1/100

Heat insulation material: Polyethylene foam with


thickness more than 8 mm.

MAX 700mm

Drain test
The air conditioner uses a drain pump to drain water.
Use the following procedure to test the drain pump operation:

Feed water

Flexible drain hose


(accessory)
Main
drain pipe

Drain Pump

Drain
port

Glue the joint

Drain hose connection


Use the clip (accessory)

Drain pan

Connect the main drain pipe to the exterior


and leave it provisionally until the test comes
to an end.
Feed water to the flexible drain hose and
check the piping for leakage.
Be sure to check the drain pump for normal
operating and noise when electrical wiring is
complete.
When the test is complete, connect the flexible drain hose to the drain port on the indoor
unit.

CAUTION
The supplied flexible drain hose should not be strained.
A strained hose may cause leakage of water.

Max 300mm

Hanger
distance
1~15m

Hanger Bracket
1/50~1/100 slope

Metal
clamp
Flexible drain hose

Max 700mm

Cassette 1-way

10.5 Indoor Unit Drain Piping

Insulation

HAND OVER
Teach the customer the operation and maintenance procedures, using the operation manual.
(air filter cleaning, temperature control, etc.)
Flexible drain hose

1-16

Indoor unit

Ceiling Cassette 1-way

CAUTION

WIRED REMOTE CONTROLLER INSTALLATION


Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place away
from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.

Do not install the remote controller where it can be affected by:


- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)

TEMP

yes

Remote Controller

no

TEMP

Remote Controller

5feet
(1.5meters)

TEMP

Controller
Remote

no

no

Fig.1 Typical locations for remote controller

Ceiling Cassette 1-way

Indoor unit

1-17

Cassette 1-way

After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have separate power specially for the air conditioner. As for the method of wiring, follow the circuit diagram pasted on the inside of control box cover.
2) Provide a circuit breaker switch between power source and the unit.
3) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations
to which the unit is subjected during the course of transportation. Check them and make sure that they are all
tightly fastened. (If they are loose, it could give rise to burn-out of the wires.)
4) Confirm the Specification of power source
5) Confirm that electrical capacity is sufficient.
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the
name plate.
7) Confirm that the cable thickness is as specified in the power sources specification.
(Particularly note the relation between cable length and thickness.)
8) Do not install the leakage breaker in a place which is wet or moist.
Water or moist may cause short circuit.
9) The following troubles would be caused by voltage drop-down.
Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to the normal
function of a overload protection device.
Proper starting power is not given to the compressor.

11. Accessories

Cassette 1-way

Standard Accessories
Name

Clamp metal

Drain hose

Insulation for
fitting

Quantity

2 EA

1 EA

1 set

Washer for
hanging bracket
8 EA

Clamp
(Tie Wrap)

Bolt

4 EA

4 EA

Screw

(Other)

3 EA
Paper pattern for
installation
Owner's manual
Installation manual

Shape

for gas pipe

for liquid pipe


Screws for fixing panels are attached to decoration panel.

CAUTION
Use only those accessories (Standard or optional) which have designated specifications.

1-18

Indoor unit

Ceiling Cassette 1-way

1. List of functions
2. Specifications
3. Dimensions
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. Air Velocity and Temperature Distribution
8. Electric Characteristics
9. Sound Levels
10. Installation
11. Accessories

Ceiling Cassette 2-way

Indoor unit

Cassette 2-way

Ceiling Cassette 2-Way

1. List of functions

Cassette 2-way

Category

Air flow

Air purifying

Installation

Reliability

Convenience

Individual
control

Special
function kit

Function
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Wide wired remote controller
Deluxe wired remote controller
Simple wired remote controller
Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
Zone control
CTIE
Electro thermostat

ARNU18GTL*2, ARNU24GTL*2
2
Auto
O
4/5/4
X
O
O
X
Option
O
O
O
X
O
O
O
O
O(Heat recovery)
X
O(Heat pump or Cooling only)
O
O
O
O
O
O
O
O
Accessory
Accessory
Accessory
Accessory
X
Accessory
-

O : Applied
X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

2-1

Indoor unit

Ceiling Cassette 2-way

2. Specifications
* Model Name
A:Basic, C:Plasma
Type
Model
Cooling Capacity

Heating Capacity
Casing
Body
Dimensions (WxDxH)
Front Panel
Coil

Fan

Rows x Columns x FPI


Face Area
Type
Motor Output x Number
Running Current
Air Flow Rate(H/M/L)

mm
inch
mm
inch
m2
W
A
CMM
cfm

Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Safety Device
Liquid Side
mm(inch)
Pipe Connections Gas Side
mm(inch)
Drain Pipe(Internal Dia.)
mm
Net Weight
Body
kg(lbs)
Noise Level(Sound Press, 1.5m, H/M/L) dB(A)3
Power Supply
Refrigerant Control
Power cable
Transmission cable
Panel Color
Panel Name(Accessory)

, V, Hz

2Way Ceiling Cassette


ARNU18GTL*2
5.6
4,800
19,100
6.3
5,400
21,500
Galvanized Steel Plate
830x550x225
32.6x21.6x8.9
1,050x640x28.5
41.3x25.2x1.1
2x11x20
0.13
Cross Flow Fan
20x2
0.18x2
13/12/10
459/424/353
Direct
BLDC
Microprocessor, Thermostat for cooling and heating
Foamed polystrene
Fuse
6.35(1/4)
12.7(1/2)
25.0
22(48.5)
40/35/30
1, 220 ~ 240, 50
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.25 x 2C
Morning fog
PT-HL*

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are Net Capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve

Ceiling Cassette 2-way

Indoor unit

Cassette 2-way

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

2-2

Cassette 2-way

* Model Name
A:Basic, C:Plasma
Type
Model
Cooling Capacity

Heating Capacity

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h

Casing
Body
Dimensions (WxDxH)
Front Panel
Coil

Fan

Rows x Columns x FPI


Face Area
Type
Motor Output x Number
Running Current
Air Flow Rate(H/M/L)

mm
inch
mm
inch
m2
W
A
CMM
cfm

Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Safety Device
Liquid Side
mm(inch)
Pipe Connections Gas Side
mm(inch)
Drain Pipe(Internal Dia.)
mm
Net Weight
Body
kg(lbs)
Noise Level(Sound Press, 1.5m, H/M/L) dB(A)3
Power Supply
Refrigerant Control
Power cable
Transmission cable
Panel Color
Panel Name(Accessory)

, V, Hz

2Way Ceiling Cassette


ARNU24GTL*2
7.1
6,100
24,200
8.0
6,900
27,300
Galvanized Steel Plate
830x550x225
32.6x21.6x8.9
1,050x640x28.5
41.3x25.2x1.1
2x11x20
0.13
Cross Flow Fan
20x2
0.18x2
17/15/13
601/530/459
Direct
BLDC
Microprocessor, Thermostat for cooling and heating
Foamed polystrene
Fuse
9.52(3/8)
15.88(5/8)
25.0
22(48.5)
42/37/32
1, 220 ~ 240, 50
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.25 x 2C
Morning fog
PT-HL*

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are Net Capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve

2-3

Indoor unit

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

Ceiling Cassette 2-way

Indoor unit

35.6

144.2

893

931.2
830
2
205.5
1

69.2

34
482
550

177.1
225

6.5

92

Air discharge grill

Unit size(24k):15.88

Unit size(18k):12.7

Unit size(24k):9.52

Unit size(18k):6.35

Descripition

(unit : mm)

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

CHASSIS CODE: TL

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Note

Air suction grill

Gas pipe connection

2
3

Liquid pipe connection

Name

Number

ARNU18GTL*2
ARNU24GTL*2

Cassette 2-way

Ceiling Cassette 2-way


206.5
69.2

Ceiling Cassette 2-way

3. Dimensions

2-4

162.4

Cassette 2-way

4. Piping Diagrams

Heat Exchanger

EEV

Filter

:Cooling
:Heating

Th2

Th3
C.F.F.

Filter
Th1

lndoor unit

Refrigerant pipe connection port diameter


[Unit: mm(inch)]

2-5

Model

Gas

Liquid

ARNU18GTL*2

12.7(1/2)

6.35(1/4)

ARNU24GTL*2

15.88(5/8)

9.52(3/8)

LOC.

Description

Th1

Room thermistor

Th2

Pipe in thermistor

Th3

Pipe out thermistor

Indoor unit

Ceiling Cassette 2-way

5. Wiring Diagrams
TL Chassis

Cassette 2-way

CONNECTOR NUMBER
CN-POWER
CN-MOTOR1
CN-MOTOR2
CN-D/PUMP
CN-485
CN-DISP
CN-EEV
CN-VANE2
CN-FLOAT
CN-PIPE/IN
CN-PIPE/OUT
CN-ROOM
CN-REMO

SPEC
AC Power supply
Fan motor output
Fan motor output
Drain pump output
Communication
Display
EEV Output
Step motor
Float switch input
Suction pipe sensor
Discharge pipe sensor
Room sensor
Remote controller

Dip Switch Setting


SW3
GROUP

Off
Master

On
Slave

SW4

DRY CONTACT

Variable

Auto

SW5

EXTRA 1

Off

On

DESCRIPTION
AC Power line input for indoor controller
Motor output of BLDC
Motor output of BLDC
AC output for drain pump
Connection between indoor and outdoor
Display of indoor status
EEV Control output
Step motor output
Float switch sensing
Pipe in thermistor
Pipe out thermistor
Room air thermistor
Remote control line
Remarks
Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

Ceiling Cassette 2-way

Indoor unit

2-6

6. Capacity Tables

Cassette 2-way

6.1 Cooling Capacity

Capacity
Index

5.6

20
14
TC SHC
kW kW

23
16
TC SHC
kW kW

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

30
22
TC SHC
kW
kW

32
24
TC SHC
kW kW

10

3.8

3.2

4.5

3.6

5.2

3.9

5.6

3.9

6.0

4.0

6.7

4.2

7.4

4.2

12

3.8

3.2

4.5

3.6

5.2

3.9

5.6

3.9

6.0

4.0

6.7

4.2

7.3

4.1

14

3.8

3.2

4.5

3.6

5.2

3.9

5.6

3.9

6.0

4.0

6.7

4.2

7.2

4.1

16

3.8

3.2

4.5

3.6

5.2

3.9

5.6

3.9

6.0

4.0

6.7

4.2

7.1

4.0

18

3.8

3.2

4.5

3.6

5.2

3.9

5.6

3.9

6.0

4.0

6.7

4.2

7.0

4.0

20

3.8

3.2

4.5

3.6

5.2

3.9

5.6

3.9

6.0

4.0

6.7

4.2

6.9

3.9

21

3.8

3.2

4.5

3.6

5.2

3.9

5.6

3.9

6.0

4.0

6.7

4.2

6.8

3.9

23

3.8

3.2

4.5

3.6

5.2

3.9

5.6

3.9

6.0

4.0

6.7

4.2

6.7

3.8

25

3.8

3.2

4.5

3.6

5.2

3.9

5.6

3.9

6.0

4.0

6.6

4.2

6.6

3.8

27

3.8

3.2

4.5

3.6

5.2

3.9

5.6

3.9

6.0

4.0

6.4

4.1

6.6

3.7

29

3.8

3.2

4.5

3.6

5.2

3.9

5.6

3.9

6.0

4.0

6.4

4.0

6.5

3.7

31

3.8

3.2

4.5

3.6

5.2

3.9

5.6

3.9

6.0

4.0

6.3

3.9

6.4

3.6

33

3.8

3.2

4.5

3.6

5.2

3.9

5.6

3.9

6.0

4.0

6.2

3.9

6.3

3.6

35

3.8

3.2

4.5

3.6

5.2

3.9

5.6

3.9

6.0

4.0

6.0

3.8

6.2

3.5

37

3.8

3.2

4.5

3.6

5.2

3.9

5.6

3.9

5.8

3.9

5.9

3.7

6.1

3.5

39

3.8

3.2

4.5

3.6

5.2

3.9

5.6

3.9

5.7

3.9

5.8

3.7

6.0

3.4

Outdoor
air temp.
(DB, C)

Notes:
TC: Total Capacity(kW)

2-7

Cooling capacity

SHC: Sensible Heat Capacity(kW)

Indoor unit

Ceiling Cassette 2-way

Cooling capacity

Capacity
Index

23
16
TC SHC
kW kW

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

30
22
TC SHC
kW
kW

32
24
TC SHC
kW kW

10

4.8

4.1

5.7

4.5

6.6

4.9

7.1

5.0

7.6

5.1

8.5

5.3

9.3

5.3

12

4.8

4.1

5.7

4.5

6.6

4.9

7.1

5.0

7.6

5.1

8.5

5.3

9.2

5.2

14

4.8

4.1

5.7

4.5

6.6

4.9

7.1

5.0

7.6

5.1

8.5

5.3

9.1

5.2

16

4.8

4.1

5.7

4.5

6.6

4.9

7.1

5.0

7.6

5.1

8.5

5.3

9.0

5.1

18

4.8

4.1

5.7

4.5

6.6

4.9

7.1

5.0

7.6

5.1

8.5

5.3

8.8

5.0

20

4.8

4.1

5.7

4.5

6.6

4.9

7.1

5.0

7.6

5.1

8.5

5.3

8.7

5.0

21

4.8

4.1

5.7

4.5

6.6

4.9

7.1

5.0

7.6

5.1

8.5

5.3

8.7

4.9

23

4.8

4.1

5.7

4.5

6.6

4.9

7.1

5.0

7.6

5.1

8.5

5.3

8.5

4.9

25

4.8

4.1

5.7

4.5

6.6

4.9

7.1

5.0

7.6

5.1

8.4

5.3

8.4

4.8

27

4.8

4.1

5.7

4.5

6.6

4.9

7.1

5.0

7.6

5.1

8.2

5.1

8.3

4.7

29

4.8

4.1

5.7

4.5

6.6

4.9

7.1

5.0

7.6

5.1

8.1

5.1

8.2

4.7

31

4.8

4.1

5.7

4.5

6.6

4.9

7.1

5.0

7.6

5.1

8.0

5.0

8.1

4.6

33

4.8

4.1

5.7

4.5

6.6

4.9

7.1

5.0

7.6

5.1

7.8

4.9

7.9

4.5

35

4.8

4.1

5.7

4.5

6.6

4.9

7.1

5.0

7.6

5.1

7.7

4.8

7.8

4.4

37

4.8

4.1

5.7

4.5

6.6

4.9

7.1

5.0

7.4

5.0

7.5

4.7

7.7

4.4

39

4.8

4.1

5.7

4.5

6.6

4.9

7.1

5.0

7.2

4.9

7.4

4.6

7.6

4.3

Notes:
TC: Total Capacity(kW)

Ceiling Cassette 2-way

SHC: Sensible Heat Capacity(kW)

Indoor unit

2-8

Cassette 2-way

7.1

20
14
TC SHC
kW kW

Outdoor
air temp.
(DB, C)

Cassette 2-way

6.2 Heating Capacity


Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

5.6

Heating capacity
Indoor air temp. (DB, C)

16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

-19.8 -20.0

kW
4.2

kW
4.2

kW
4.2

kW
4.2

kW
4.2

kW
4.2

-18.8 -19.0

4.3

4.3

4.3

4.3

4.3

4.3

-16.7 -17.0

4.6

4.6

4.6

4.6

4.6

4.5

-14.7 -15.0

4.9

4.8

4.3

4.8

4.8

4.8

-12.6 -13.0

5.1

5.1

4.5

5.0

5.0

5.0

-10.5 -11.0

5.4

5.4

4.8

5.4

5.3

5.3

-9.5 -10.0

5.4

5.4

4.9

5.4

5.4

5.4

-8.5

-9.1

5.5

5.5

5.0

5.5

5.5

5.4

-7.0

-7.6

5.7

5.7

5.1

5.6

5.6

5.5

-5.0

-5.6

6.0

6.0

5.4

5.8

5.8

5.5

-3.0

-3.7

6.2

6.2

5.5

6.1

5.9

5.5

0.0

-0.7

6.6

6.6

5.8

6.1

5.9

5.5

3.0

2.2

7.0

6.7

6.2

6.1

5.9

5.5

5.0

4.1

7.1

6.7

6.3

6.1

5.9

5.5

7.0

6.0

7.2

6.7

6.3

6.1

5.9

5.5

9.0

7.9

7.2

6.7

6.3

6.1

5.9

5.5

11.0

9.8

7.2

6.7

6.3

6.1

5.9

5.5

13.0 11.8

7.2

6.7

6.3

6.1

5.9

5.5

15.0 13.7

7.2

6.7

6.3

6.1

5.9

5.5

Notes:
TC: Total Capacity(kW)

2-9

Indoor unit

Ceiling Cassette 2-way

Heating capacity
Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

-19.8 -20.0

kW
5.4

kW
5.4

kW
5.4

kW
5.3

kW
5.3

kW
5.3

-18.8 -19.0

5.5

5.5

5.5

5.5

5.4

5.4

-16.7 -17.0

5.8

5.8

5.8

5.8

5.8

5.8

-14.7 -15.0

6.2

6.1

5.5

6.1

6.1

6.1

-12.6 -13.0

6.5

6.5

5.8

6.4

6.4

6.4

-10.5 -11.0

6.8

6.8

6.0

6.8

6.7

6.7

-9.5 -10.0

6.9

6.9

6.2

6.9

6.9

6.8

-8.5

-9.1

7.0

7.0

6.3

7.0

7.0

6.8

-7.0

-7.6

7.3

7.3

6.5

7.1

7.1

7.0

-5.0

-5.6

7.6

7.6

6.8

7.4

7.4

7.0

-3.0

-3.7

7.9

7.9

7.0

7.7

7.5

7.0

0.0

-0.7

8.4

8.4

7.4

7.8

7.5

7.0

3.0

2.2

8.9

8.6

7.8

7.8

7.5

7.0

5.0

4.1

9.0

8.6

8.0

7.8

7.5

7.0

7.0

6.0

9.2

8.6

8.0

7.8

7.5

7.0

9.0

7.9

9.2

8.6

8.0

7.8

7.5

7.0

11.0

9.8

9.2

8.6

8.0

7.8

7.5

7.0

13.0 11.8

9.2

8.6

8.0

7.8

7.5

7.0

15.0 13.7

9.2

8.6

8.0

7.8

7.5

7.0

Notes:
TC: Total Capacity(kW)

Ceiling Cassette 2-way

Indoor unit

2-10

Cassette 2-way

7.1

Indoor air temp. (DB, C)

7. Air Velocity and Temperature Distribution(Reference Data)

Cassette 2-way

ARNU24GTL*2
Cooling

Heating

Discharge angle: 40

Discharge angle: 60

Air velocity [m/s]

Air velocity [m/s]


2.7m

2.0

2.5

3.0

3.0

2.5

1.5

1.5

1.0

1.0

0.5

4m

2.7m
2.5
2.0

2m

2.0

1.5

1m

2m

1m

0m

1m

2m

0m
4m

3m

Temperature [C]

21

20

20

0.5

4m

3m

2m

22

1m

2m

0m
4m

3m

24

1m

28

1m

0m

1m

2m

3m

0m
4m

4m

27

3m

2m

Indoor unit

1m

29

2.7m

32
31

30

26

2-11

0m

32
31

2m

23

24

2m

0.5

1m

2.7m
21

23

3m

1m

1.0

Temperature [C]

22

4m

2m

1.5

1.0

0.5

3m

2.5
2.0

2m

30
27

28

29
28

0m

1m

28
27

1m

26

2m

3m

0m
4m

Ceiling Cassette 2-way

8. Electric Characteristics
Units
Model

Type

ARNU18GTL*2

TL

ARNU24GTL*2

TL

ARNU18GTL*2

TL

ARNU24GTL*2

TL

Power Supply
Hz

Volts

50

220~240

60

220

Voltage Range MCA

IFM

Input(W)

MFA

kW

FLA

Cooling Heating

Max:264

1.52

15

0.04

0.41

70

70

Min:198

1.52

15

0.04

0.41

70

70

Max:242

1.52

15

0.04

0.41

70

70

Min:198

1.52

15

0.04

0.41

70

70
Cassette 2-way

Symbols:
MCA : Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
IFM : Indoor Fan Motor
Note :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA + 1
MFA 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the larger value on the MCA.
5. Instead of fuse, use Circuit Breaker.

Ceiling Cassette 2-way

Indoor unit

2-12

9. Sound Levels

Cassette 2-way

Overall
Notes:
- Sound measured at 1.5m away from the center of the unit.
- Data is valid at free field condition
- Data is valid at nominal operating condition
- Reference accoustic pressure OdB = 20Pa
- Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment is installed.

1.5m
Microphone

Sound Levels dB(A)

Model

ARNU18GTL*2

40

35

30

ARNU24GTL*2

42

37

32

Sound Pressure Level


ARNU18GTL*2

ARNU24GTL*2
80

70

70

NC-65

60

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
NC-25

20

10

Approximate
Hearing
Threshold
63

NC-65
60
NC-60

125

250

500

NC-15
1000 2000 4000 8000

NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
NC-25

20
Approximate
Hearing
Threshold

NC-20

Octave Band Center Frequency (Hz)

2-13

Octave Band Sound Pressure Level (dB re 20Pa )

Octave Band Sound Pressure Level (dB re 20Pa )

80

NC-20
NC-15

10
63

125

250

500

1000

2000

4000

8000

Octave Band Center Frequency (Hz)

Indoor unit

Ceiling Cassette 2-way

10. Installation
Please read the instruction sheets completely before installing the product.
When the power cord is damaged, replacement work shall be performed by authorized personnel only.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Cassette 2-way

Anti-bacteria filter
TEMP

Remote Controller

Air Intake
Air Outlet

Required Parts
Connecting cable
Pipes: Gas side
Liquid side
Hanging Bolt
(W 3/8 or M10 length 650mm)
Insulated drain hose
Additional Drain hose

Required Tools
Level
Screw driver
Electric drill
Hole core drill
Flaring Tool set
Torque Wrenches
Hexagonal Wrench
Gas-leak detector
Thermometer

Ceiling Cassette 2-way

Ceiling Board

50 or
more

30 or less

50 or
more

Above 200
300 or less

Ceiling
Ceiling Board

100
or more

There should not be any heat source or steam near the


unit.
There should not be any obstacles to the air circulation.
A place where air circulation in the room will be good.
A place where drainage can be easily obtained.
A place where noise prevention is taken into consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the wall,
ceiling, or other obstacles.
The indoor unit must have sufficient maintenance
space.

20 or more

10.1 Selection of the best location

Unit:cm
Floor

Indoor unit

2-14

Cassette 2-way

10.2 Ceiling opening dimensions and hanging bolt location


The dimensions of the paper pattern for installation
are the same as those of the ceiling opening
dimensions.
Ceiling board

Ceiling
Level gauge

CAUTION
This air-conditioner uses a drain pump.
Install the unit horizontally using a level gauge.
During the installation, care should be taken not to
damage electric wires.

Select and mark the position for fixing bolts and


piping hole.
Decide the position for fixing bolts slightly tilted
to the drain direction after considering the direction of drain hose.
Drill the hole for anchor bolt on the wall.

NOTE:
Avoid the following installation location.
1. Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated.
These may cause heat exchange efficiency reduction, or water drops, drain pump mal-function.
In these cases, take the following actions;
Make sure that ventilation fan is enough to cover all noxious gases from this place.
Ensure enough distance from the cooking room to install the air conditioner in such a place where it may
not suck oily steam.

Air conditioner

Take enough
distance
Use the ventilation fan
for smoke-collecting
hood with sufficient
capacity.
Cooking table

2. Avoid installng air conditioner in such places where cooking oil or iron powder is generated.
3. Avoid places where inflammable gas is generated.
4. Avoid place where noxious gas is generated.
5. Avoid places near high frequency generators.

2-15

Indoor unit

Ceiling Cassette 2-way

Ceiling

Nut
(W3/8 or M10)

90mm

Keep the length of the bolt


from the bracket to 40mm

Hanging bolt
(W3/8 or M10)

Flat washer for M10


False
(accessory)
ceiling board

Set screw of
paper pattern (4 pieces)

Paper pattern
for installation

Open the ceiling board


along the outer edge of the
paper pattern

Adjust the same height

The following parts are locally purchased.


Hanging Bolt - W 3/8 or M10
Nut
- W 3/8 or M10
Spring Washer - M10
Plate Washer - M10

False ceiling board

Cassette 2-way

Flat washer for M10


(accessory)
Nut
(W3/8 or M10)

Air Conditioner body

CAUTION
Tighten the nut and bolt to prevent the unit
from falling.

10.3 Wiring Connection


Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit
respectively.

Terminal Block Indoor


1(L)

2(N)

SODU

INTERNET DRY1 DRY2 GND 12V

IDU
-

Outdoor
Unit

INDOOR POWER INPUT

WARNING
Make sure that the screws of the terminal are not loose.

Ceiling Cassette 2-way

Indoor unit

2-16

Cassette 2-way

10.4 Installation of Decoration Panel


Before installing the decoration panel,
always remove the paper template.

The decoration panel has its installation


direction.

1. Temporarily fix two decoration panel fixing screws (hexagon M5 screw) on the unit body. (Tighten by amount 10mm in
length.)
The fixing screws (hexagon M5 screw) are included in the indoor unit box.
2. Remove the air inlet grille from the decoration panel. (Remove the hook for the air inlet grille cord.)
3. Hook the decoration panel key hole (
) on the screws fixed in step above, and slide the panel so that the screws
reach the key hole edge.
4. Retighten completely two temporarily fixed screws and other two screws. (Total 4 screws)
5. Connect the louver motor connector and display connector.
6. After tightening these screws, install the air inlet grille
(including the air filter).
Air conditioner unit
Decorative panel
fixing screws
(hexagon M6 screws)
Temporary fitting
at 2 poles
(Tightening about 10mm)

Piping side

Control box cover


Cover

Plasma filter

Louver motor

Key holes

Decorative panel
fixing screws
(Hexagon M6 screw)

Decorative panel
Push

Ratch
pull

Inlet Grille

CAUTION
Install the decoration panel
otherwise cool air leakage
causes condensation.
Water drops fall.

Correct method

Wrong method
Air conditioner
unit
Cool air leakage
(no good)
Ceiling
board
Decoration panel

Air conditioner
unit
Ceiling
board
Decoration panel

Fit the insulator (this part) and


be careful for cool air leakage

2-17

Indoor unit

Ceiling Cassette 2-way

10.5 Indoor Unit Drain Piping

Upward
routing
not allowed

Pipe clamp

Drain piping must have down-slope (1/50 to 1/100): Make sure


not to provide up-and-down slope to prevent reversal flow.
During drain piping connection, be careful not to exert extra
force on the drain port on the indoor unit.
The outside diameter of the drain connection on the indoor
unit is 32mm.

Indoor unit

Maintenance
drain port

1/50~1/100

Make sure to install heat insulation on the drain piping.

MAX 700mm

Heat insulation material: Polyethylene foam with


thickness more than 8 mm.

Drain test
The air conditioner uses a drain pump to drain water.
Use the following procedure to test the drain pump operation:

Feed water

Flexible drain hose


(accessory)
Main
drain pipe

Drain Pump

Drain
port

Glue the joint

Drain hose connection


Use the clip (accessory)

Connect the main drain pipe to the exterior and leave it


provisionally until the test comes to an end.
Feed water to the flexible drain hose and check the piping for leakage.
Make sure to check the drain pump for normal operating
and noise when electrical wiring is complete.
When the test is complete, connect the flexible drain
hose to the drain port on the indoor unit.

Drain pan
CAUTION

The supplied flexible drain hose should not be strained.


A strained hose may cause leakage of water.

Max 300mm

Hanger
distance
1~15m

Metal
clamp
Flexible drain hose

Hanger Bracket
1/50~1/100 slope
Max 700mm

CAUTION

Insulation

Ceiling Cassette 2-way

Indoor unit

2-18

Cassette 2-way

Piping material: Polyvinyl chloride pipe inner


diometes 25mm and pipe fittings

CAUTION

Cassette 2-way

CAUTION
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have separate power specially for the air conditioner. As for the method of wiring, follow the circuit diagram
pasted on the inside of control box cover.
2) Provide a circuit breaker switch between power source and the unit.
3) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the
unit is subjected during the course of transportation. Check them and make sure that they are all tightly fastened. (If they
are loose, it could give rise to burn-out of the wires.)
4) Confirm the specification of power source
5) Confirm that electrical capacity is sufficient.
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate.
7) Confirm that the cable thickness is as specified in the power sources specification.
(Particularly note the relation between cable length and thickness.)
8) Do not install the leakage breaker in a place which is wet or moist.
Water or moist may cause short circuit.
9) The following troubles would be caused by voltage drop-down.
Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to the normal function of a overload protection device.
Proper starting power is not given to the compressor.

HAND OVER
Teach the customer the operation and maintenance procedures, using the operation manual.
(air filter cleaning, temperature control, etc.)

WIRED REMOTE CONTROLLER INSTALLATION


Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place away
from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.

Do not install the remote controller where it can be affected by:


- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)

TEMP

yes

Remote Controller

no

TEMP

Controller
Remote

TEMP

Remote Controller

5feet
(1.5meters)

no

no

Fig.1 Typical locations for remote controller

2-19

Indoor unit

Ceiling Cassette 2-way

11. Accessories
Standard Accessories
Name

Clamp metal

Drain hose

Insulation for
fitting

Quantity

2 EA

1 EA

1 set

Washer for
hanging bracket
8 EA

Clamp
(Tie Wrap)
4 EA

Bolt

(Other)

4 EA

Shape

for gas pipe

for liquid pipe


Screws for fixing panels are attached to decoration panel.

CAUTION
Use only those accessories (Standard or optional) which have designated specifications.

Ceiling Cassette 2-way

Indoor unit

2-20

Cassette 2-way

Paper pattern for


installation
Owner's manual
Installation manual

Cassette 4-way

Ceiling Cassette 4-way

1. List of functions
2. Specifications
3. Dimensions
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. Air Velocity and Temperature Distribution
8. Electric Characteristics
9. Sound Levels
10. Installation
11. Accessories

Indoor unit

Ceiling Cassette 4-way

1. List of functions
Category

Air flow

Installation

Reliability

Convenience

Individual
control

Special
function kit

Air supply outlet


Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Elevation Grill
Wide wired remote controller
Deluxe wired remote controller
Simple wired remote controller
Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
Zone control
CTIE
Electro thermostat

ARNU05GTR*2, ARNU07GTR*2, ARNU09GTR*2, ARNU12GTR*2


ARNU15GTQ*2, ARNU18GTQ*2, ARNU24GTP*2, ARNU28GTP*2
ARNU36GTN*2, ARNU42GTM*2, ARNU48GTM*2
4
Auto
O
4/5/4
X
O
O
O
X
Option
O
O
O
X
O
O
O
O
O(Heat recovery)
X
O(Heat pump or Cooling only)
O
O
O
O
O
O
O
O
Accessory (TM,TN,TP only)
Accessory
Accessory
Accessory
Accessory
X
Accessory
-

O : Applied
X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.
* Plasma kit and Elevation Grille are not applicable at the same time

Ceiling Cassette 4-way

Indoor unit

3-1

Cassette 4-way

Air purifying

Function

2. Specifications

Cassette 4-way

* Model Name
A:Basic, C:Plasma
Type
Model
Cooling Capacity

Heating Capacity

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h

Casing
Body
Dimensions(WxDxH)
Front Panel
Coil

Fan

Rows x Columns x FPI


Face Area
Type
Motor Output x Number
Running Current
Air Flow Rate(H/M/L)

mm
inch
mm
inch
m2
W
A
CMM
cfm

Drive
Motor type
Temperature Control

Sound Absorbing Thermal Insulation Material


Safety Device
Liquid Side
mm(inch)
Pipe Connections Gas Side
mm(inch)
Drain Pipe(Internal Dia.)
mm
Net Weight
Body
kg(lbs)
Packaged
kg(lbs)
Noise Level(Sound Press, 1.5m, H/M/L) dB(A)3
Power Supply
Refrigerant Control
Power cable
Transmission cable
Panel Color
Panel Name(Accessory)

, V, Hz
mm2
mm2

ARNU05GTR*2
1.6
1,400
5,500
1.8
1,500
6,100
Galvanized Steel Plate
570x570x214
22.4x22.4x8.4
700x700x30
27.5x27.5x1.2
1x8x18
0.21
Turbo Fan
43x1
0.2
7.5/7.0/6.6
265/247/212
Direct
BLDC
Microprocessor,
Thermostat for cooling
and heating
Foamed polystrene
Fuse
6.35(1/4)
12.7(1/2)
25
13.1(28.9)
15.4(33.9)
36/35/33
1, 220 ~ 240, 50
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.25 x 2C
Morning fog

4 Way Ceiling Cassette


ARNU07GTR*2
ARNU09GTR*2
2.2
2.8
1,900
2,400
7,500
9,600
2.5
3.2
2,200
2,800
8,500
10,900
Galvanized Steel Plate Galvanized Steel Plate
570x570x214
570x570x214
22.4x22.4x8.4
22.4x22.4x8.4
700x700x30
700x700x30
27.5x27.5x1.2
27.5x27.5x1.2
1x8x18
2x8x18
0.21
0.21
Turbo Fan
Turbo Fan
43x1
43x1
0.2
0.2
7.5/7.0/6.6
8.0/7.5/7.1
265/247/212
283/265/251
Direct
Direct
BLDC
BLDC
Microprocessor,
Microprocessor,
Thermostat for cooling Thermostat for cooling
and heating
and heating
Foamed polystrene
Foamed polystrene
Fuse
Fuse
6.35(1/4)
6.35(1/4)
12.7(1/2)
12.7(1/2)
25
25
13.1(28.9)
14.2(31.3)
15.4(33.9)
16.5(36.3)
36/35/33
36/35/34
1, 220 ~ 240, 50
1, 220 ~ 240, 50
1, 220, 60
1, 220, 60
EEV
EEV
CV1.5 x 3C
CV1.5 x 3C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
Morning fog
Morning fog
PT-UQC

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve

3-2

Indoor unit

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

Ceiling Cassette 4-way

* Model Name
A:Basic, C:Plasma
Type
Model
Cooling Capacity

Heating Capacity
Casing
Body
Dimensions(WxDxH)
Front Panel
Coil

Fan

Rows x Columns x FPI


Face Area
Type
Motor Output x Number
Running Current
Air Flow Rate(H/M/L)

mm
inch
mm
inch
m2
W
A
CMM
cfm

Drive
Motor type
Temperature Control

Sound Absorbing Thermal Insulation Material


Safety Device
Liquid Side
mm(inch)
Pipe Connections Gas Side
mm(inch)
Drain Pipe(Internal Dia.)
mm
Net Weight
Body
kg(lbs)
Packaged
kg(lbs)
Noise Level(Sound Press, 1.5m, H/M/L) dB(A)3
Power Supply
Refrigerant Control
Power cable
Transmission cable
Panel Color
Panel Name(Accessory)

, V, Hz
mm2
mm2

ARNU12GTR*2
3.6
3,100
12,300
4.0
3,400
13,600
Galvanized Steel Plate
570x570x214
22.4x22.4x8.4
700x700x30
27.5x27.5x1.2
2x8x18
0.21
Turbo Fan
43x1
0.2
8.7/8.0/7.0
307/283/247
Direct
BLDC
Microprocessor,
Thermostat for cooling
and heating
Foamed polystrene
Fuse
6.35(1/4)
12.7(1/2)
25
14.2(31.3)
16.5(36.3)
36/35/34
1, 220 ~ 240, 50
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.25 x 2C
Morning fog

4 Way Ceiling Cassette


ARNU15GTQ*2
ARNU18GTQ*2
4.5
5.6
3,900
4,800
15,400
19,100
5.0
6.3
4,300
5,400
17,100
21,500
Galvanized Steel Plate Galvanized Steel Plate
570x570x256
570x570x256
22.4x22.4x10.1
22.4x22.4x10.1
700x700x30
700x700x30
27.5x27.5x1.2
27.5x27.5x1.2
2x10x18
2x10x18
0.27
0.27
Turbo Fan
Turbo Fan
43x1
43x1
0.2
0.2
11.0/10.0/9.3
11.2/11.0/10.0
388/353/328
396/388/353
Direct
Direct
BLDC
BLDC
Microprocessor,
Microprocessor,
Thermostat for cooling Thermostat for cooling
and heating
and heating
Foamed polystrene
Foamed polystrene
Fuse
Fuse
6.35(1/4)
6.35(1/4)
12.7(1/2)
12.7(1/2)
25
25
15.5(34.2)
15.5(34.2)
18.0(39.7)
18.0(39.7)
37/36/35
38/37/36
1, 220 ~ 240, 50
1, 220 ~ 240, 50
1, 220, 60
1, 220, 60
EEV
EEV
CV1.5 x 3C
CV1.5 x 3C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
Morning fog
Morning fog
PT-UQC

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve

Ceiling Cassette 4-way

Indoor unit

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

3-3

Cassette 4-way

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h

Cassette 4-way

* Model Name
A:Basic, C:Plasma
4 Way Ceiling Cassette
ARNU24GTP*2
ARNU28GTP*2
ARNU36GTN*2
7.1
8.2
10.6
Cooling Capacity
6,100
7,100
9,100
24,200
28,000
36,200
8.0
9.2
11.9
Heating Capacity
6,900
8,000
10,200
27,300
31,500
40,600
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
Casing
840 x 840 x 204
840 x 840 x 204
840 x 840 x 246
Dimensions
Body
mm
33.0x33.0x8.0
33.0x33.0x8.0
33.0x33.0x9.7
(WxDxH)
inch
950 x 950 x 25
950 x 950 x 25
950 x 950 x 25
Front Panel
mm
37.4 x 37.4 x 1
37.4 x 37.4 x 1
37.4 x 37.4 x 1
inch
2 x 8 x 19
2 x 8 x 19
2x10x19
Coil
Rows x Columns x FPI
0.40
0.40
0.57
Face Area
m2
Turbo Fan
Turbo Fan
Turbo Fan
Fan
Type
30
30
135
Motor Outputx Number
W
0.15
0.15
0.56
Running Current
A
17/15/13
19/16/14
25/21/19
Air Flow Rate(H/M/L)
CMM
600/529/459
671/565/494
883/742/671
cfm
Direct
Direct
Direct
Drive
BLDC
BLDC
BLDC
Motor type
Microprocessor, Thermostat for cooling and heating
Temperature Control
Foamed polystrene
Foamed polystrene
Foamed polystrene
Sound Absorbing Thermal Insulation Material
Fuse
Fuse
Fuse
Safety Device
9.52(3/8)
9.52(3/8)
9.52(3/8)
Pipe
Liquid Side
mm(inch)
15.88(5/8)
15.88(5/8)
15.88(5/8)
Connections
Gas Side
mm(inch)
25.0
25.0
25.0
Drain Pipe(Internal Dia.)
mm
20.8(45.8)
20.8(45.8)
23.5(51.8)
Net Weight
Body
kg(lbs)
38/35/31
39/38/32
43/40/39
Noise Level (Sound Press, 1.5m, H/M/L)
dB(A) 3
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
Power Supply
, V, Hz
1, 220, 60
1, 220, 60
1, 220, 60
EEV
EEV
EEV
Refrigerant Control
CV2.0 X 3C
CV2.0 X 3C
CV2.0 X 3C
Power cord
CVV-SB 1.25 X 2C
CVV-SB 1.25 X 2C
CVV-SB 1.25 X 2C
Transmission cable
Morning fog
Morning fog
Morning fog
Panel Color
PT-UMC
Panel Name(Accessory)
PTEGM0
Elevation Grill(Accessory)
Type
Model

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve

3-4

Indoor unit

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

Ceiling Cassette 4-way

* Model Name
A:Basic, C:Plasma
Type
Model
Cooling Capacity

Heating Capacity

Body
Front Panel

Coil
Fan

Rows x Columns x FPI


Face Area
Type
Motor Outputx Number
Running Current
Air Flow Rate(H/M/L)

mm
inch
mm
inch
m2
W
A
CMM
cfm

Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Safety Device
Pipe
Liquid Side
mm(inch)
Connections
Gas Side
mm(inch)
Drain Pipe(Internal Dia.)
mm
Net Weight
Body
kg(lbs)
Noise Level (Sound Press, 1.5m, H/M/L)
dB(A) 3
Power Supply
, V, Hz
Refrigerant Control
Power cord
Transmission cable
Panel Color
Panel Name(Accessory)
Elevation Grill(Accessory)

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve

Ceiling Cassette 4-way

Indoor unit

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

3-5

Cassette 4-way

Casing
Dimensions
(WxDxH)

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h

4 Way Ceiling Cassette


ARNU42GTM*2
ARNU48GTM*2
12.3
14.1
10,600
12,100
42,000
48,100
13.8
15.9
11,000
13,200
43,800
51,200
Galvanized Steel Plate
Galvanized Steel Plate
840x840x288
840x840x288
33.0x33.0x11.3
33.0x33.0x11.3
950 x 950 x 25
950 x 950 x 25
37.4 x 37.4 x 1
37.4 x 37.4 x 1
2 x 12 x 19
2 x 12 x 19
0.57
0.57
Turbo Fan
Turbo Fan
135
135
0.56
0.56
30/27/24
31/29/27
1,059/954/848
1,059/1,024/954
Direct
Direct
BLDC
BLDC
Microprocessor, Thermostat for cooling and heating
Foamed polystrene
Foamed polystrene
Fuse
Fuse
9.52(3/8)
9.52(3/8)
15.88(5/8)
15.88(5/8)
25.0
25.0
25.6(56.4)
25.6(56.4)
47/44/42
48/47/45
1, 220 ~ 240, 50
1, 220 ~ 240, 50
1, 220, 60
1, 220, 60
EEV
EEV
CV2.0 X 3C
CV2.0 X 3C
CVV-SB 1.25 X 2C
CVV-SB 1.25 X 2C
Morning fog
Morning fog
PT-UMC
PTEGM0

55

380(Air outlet hole)


473
700

378.6

4-R
2

0
378.6
380(Air outlet hole)
700
22.5

172

523
59.5
84.5
30 19
142.5

2 1

79
53
48

Indoor unit
570

165

461
570

517

128

R3
5

570

517

Air suction grill

(unit : mm)

Unit size(5k, 7k, 9k, 12k):12.7

Unit size(5k, 7k, 9k, 12k):6.35

Descripition

CHASSIS CODE: TR

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Note

Air discharge grill

Power supply connection

Gas pipe connection


Drain pipe connection

2
4

Liquid pipe connection

Name

Number

ARNU05GTR*2
ARNU07GTR*2
ARNU09GTR*2
ARNU12GTR*2

Ceiling Cassette 4-way

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

Branch Duct Connection

63

69

34.5

3-6
214

Cassette 4-way

3. Dimensions

Ceiling Cassette 4-way

55

380(Air outlet hole)


473
700

30 19
142.5

2 1

174
570

165

461
570

517

570

Liquid pipe connection


Gas pipe connection
Drain pipe connection
Power supply connection
Air discharge grill
Air suction grill

1
2
3
4
5
6

(unit : mm)

Unit size(15k, 18k):12.7

Unit size(15k, 18k):6.35

Descripition

CHASSIS CODE: TQ

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Note

Name

Number

ARNU15GTQ*2
ARNU18GTQ*2

Ceiling Cassette 4-way

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

Branch Duct Connection

63

68

76
94

R3
5

517
256

0
4-R
2
378.6
380(Air outlet hole)
700
22.5

378.6

523
59.5
125
95.5

172

79
48

Indoor unit

3-7

Cassette 4-way

Ceiling Cassette 4-way

Indoor unit

54

500(Air outlet hole)


734
950

4-

R2

500(Air outlet hole)


618
950

25

292

671

108 60

204
154

65 40

618

79
41.5

350

840

165

840

787

787

804

53.5

62

R35

Air discharge grill


Air suction grill

5
6

(unit : mm)

Unit size(24k, 28k):15.88

Unit size(24k, 28k):9.52

Descripition

CHASSIS CODE: TP

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Note

Drain pipe connection


Power supply connection

Gas pipe connection

2
4

Liquid pipe connection

Name

ARNU24GTP*2
ARNU28GTP*2

Number

Cassette 4-way

Ceiling Cassette 4-way

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

Branch Duct Connection

80

204

3-8
684
840

A direction View

60
82
99

126

Ceiling Cassette 4-way

Indoor unit

3-9

246
195

2
110

60
840

165

840

40

350

80

103
141

246

62

Gas pipe connection


Drain pipe connection
Power supply connection
Air discharge grill
Air suction grill

3
4
5
6

Unit size(36k):15.88

Unit size(36k):9.52

Descripition

(unit : mm)

CHASSIS CODE: TN

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Note

Liquid pipe connection

Name

Number

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

Branch Duct Connection

53.5

ARNU36GTN*2

Ceiling Cassette 4-way

Cassette 4-way

Ceiling Cassette 4-way


107

126

78

A direction View

100
52

R35

25

1
165

840

350

53.5

3-10

Indoor unit
100
84

A direction View
126

288

237

25

Air discharge grill


Air suction grill

5
6

(unit : mm)

Unit size(42k, 48k):15.88

Unit size(42k, 48k):9.52

Descripition

CHASSIS CODE: TM

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Note

Drain pipe connection


Power supply connection

Gas pipe connection

2
3

Liquid pipe connection

Name

ARNU42GTM*2
ARNU48GTM*2

Number

Cassette 4-way

Ceiling Cassette 4-way

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

Branch Duct Connection

109

R35

Ceiling Cassette 4-way

4. Piping Diagrams

Heat Exchanger

:Cooling
:Heating

EEV
Filter

Th3

Th2
Turbo Fan

Th1

Cassette 4-way

Filter

lndoor unit

Refrigerant pipe connection port diameter


[Unit: mm(inch)]

Model

Gas

Liquid

ARNU05GTR*2

12.7(1/2)

6.35(1/4)

ARNU07GTR*2

12.7(1/2)

6.35(1/4)

ARNU09GTR*2

12.7(1/2)

6.35(1/4)

ARNU12GTR*2

12.7(1/2)

6.35(1/4)

ARNU15GTQ*2

12.7(1/2)

6.35(1/4)

ARNU18GTQ*2

12.7(1/2)

6.35(1/4)

ARNU24GTP*2

15.88(5/8)

9.52(3/8)

ARNU28GTP*2

15.88(5/8)

9.52(3/8)

ARNU36GTN*2

15.88(5/8)

9.52(3/8)

ARNU42GTM*2

15.88(5/8)

9.52(3/8)

ARNU48GTM*2

15.88(5/8)

9.52(3/8)

LOC.

Description

Th1

Room thermistor

Th2

Pipe in thermistor

Th3

Pipe out thermistor

Ceiling Cassette 4-way

Indoor unit

3-11

5. Wiring Diagrams

Cassette 4-way

TR/TQ Chassis

CONNECTOR NUMBER
CN-POWER
CN-MOTOR1
CN-D/PUMP
CN-485
CN-DISP
CN-EEV
CN-VANE2
CN-FLOAT
CN-PIPE/IN
CN-PIPE/OUT
CN-ROOM
CN-REMO
CN-CC
CN-AIRC

LOCATION POINT
AC Power supply
Fan motor output
Drain pump output
Communication
Display
EEV Output
Step motor
Float switch input
Suction pipe sensor
Discharge pipe sensor
Room sensor
Remote controller
Dry contact
Air clean

Dip Switch Setting


SW3
GROUP

Off
Master

On
Slave

SW4

DRY CONTACT

Variable

Auto

SW5

EXTRA 1

Off

On

FUNCTION
AC Power line input for indoor controller
Motor output of BLDC
AC output for drain pump
Connection between indoor and outdoor
Display of indoor status
EEV Control output
Step motor output
Float switch sensing
Pipe in thermistor
Pipe out thermistor
Room air thermistor
Remote control line
Dry contact line
Air cleaner control
Remarks
Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

3-12

Indoor unit

Ceiling Cassette 4-way

TM/TN/TP Chassis

Cassette 4-way

CONNECTOR NUMBER
CN-POWER
CN-MOTOR1
CN-D/PUMP
CN-485
CN-DISP
CN-EEV
CN-VANE1 / VANE2
CN-FLOAT
CN-PIPE/IN
CN-PIPE/OUT
CN-ROOM
CN-REMO
CN-CC
CN-AIRC

LOCATION POINT
AC Power supply
Fan motor output
Drain pump output
Communication
Display
EEV Output
Step motor
Float switch input
Suction pipe sensor
Discharge pipe sensor
Room sensor
Remote controller
Dry contact
Air clean

Dip Switch Setting


SW3
GROUP

Off
Master

On
Slave

SW4

DRY CONTACT

Variable

Auto

SW5

EXTRA 1

Off

On

FUNCTION
AC Power line input for indoor controller
Motor output of BLDC
AC output for drain pump
Connection between indoor and outdoor
Display of indoor status
EEV Control output
Step motor output
Float switch sensing
Pipe in thermistor
Pipe out thermistor
Room air thermistor
Remote control line
Dry contact line
Air cleaner control
Remarks
Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

Ceiling Cassette 4-way

Indoor unit

3-13

6. Capacity Tables

Cassette 4-way

6.1 Cooling Capacity

Capacity
Index

1.6

2.2

2.8

Outdoor
air temp.
(DB, C)
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

Notes:
TC: Total Capacity(kW)

3-14

Cooling capacity

20
14
TC SHC
kW kW

23
16
TC SHC
kW kW

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

30
22
TC SHC
kW
kW

1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9

1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6

1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0

1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1

1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

32
24
TC SHC
kW kW
2.1
2.1
2.1
2.0
2.0
2.0
2.0
1.9
1.9
1.9
1.8
1.8
1.8
1.8
1.7
1.7
2.9
2.9
2.8
2.8
2.7
2.7
2.7
2.6
2.6
2.6
2.5
2.5
2.5
2.4
2.4
2.3
3.7
3.6
3.6
3.5
3.5
3.4
3.4
3.4
3.3
3.3
3.2
3.2
3.1
3.1
3.0
3.0

1.3
1.3
1.3
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.1
1.1
1.1
1.1
1.1
1.1
1.8
1.7
1.7
1.7
1.7
1.6
1.6
1.6
1.6
1.6
1.5
1.5
1.5
1.5
1.5
1.4
2.1
2.1
2.1
2.1
2.0
2.0
2.0
2.0
1.9
1.9
1.9
1.9
1.8
1.8
1.8
1.7

SHC: Sensible Heat Capacity(kW)

Indoor unit

Ceiling Cassette 4-way

Cooling capacity

Capacity
Index

4.5

5.6

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

20
14
TC SHC
kW kW

23
16
TC SHC
kW kW

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

30
22
TC SHC
kW
kW

2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8

2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2

4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.7

Notes:
TC: Total Capacity(kW)

Ceiling Cassette 4-way

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2

2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6

2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9

3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6

2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9

3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0

2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0

2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2

32
24
TC SHC
kW kW
4.7
4.7
4.6
4.6
4.5
4.4
4.4
4.3
4.3
4.2
4.2
4.1
4.0
4.0
3.9
3.8
5.9
5.8
5.8
5.7
5.6
5.5
5.5
5.4
5.3
5.3
5.2
5.1
5.0
5.0
4.9
4.8
7.4
7.3
7.2
7.1
7.0
6.9
6.8
6.7
6.6
6.6
6.5
6.4
6.3
6.2
6.1
6.0

2.7
2.6
2.6
2.6
2.5
2.5
2.5
2.5
2.4
2.4
2.4
2.3
2.3
2.2
2.2
2.2
3.5
3.5
3.4
3.4
3.3
3.3
3.3
3.2
3.2
3.1
3.1
3.0
3.0
2.9
2.9
2.8
4.2
4.1
4.1
4.0
4.0
3.9
3.9
3.8
3.8
3.7
3.7
3.6
3.6
3.5
3.5
3.4

SHC: Sensible Heat Capacity(kW)

Indoor unit

3-15

Cassette 4-way

3.6

Outdoor
air temp.
(DB, C)

Cassette 4-way

Cooling capacity

20
14
TC SHC
kW kW

23
16
TC SHC
kW kW

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

7.1

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8

4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2

5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7

4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6

6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6

5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0

7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1

5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1

7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.4
7.2

5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.1
5.0

8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.4
8.2
8.1
8.0
7.8
7.7
7.5
7.4

5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.4
5.3
5.2
5.1
5.1
5.0
4.9
4.8

9.3
9.2
9.1
9.0
8.8
8.7
8.7
8.5
8.4
8.3
8.2
8.1
7.9
7.8
7.7
7.6

5.4
5.4
5.3
5.2
5.2
5.1
5.1
5.0
4.9
4.9
4.8
4.7
4.6
4.6
4.5
4.4

8.2

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9

6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6

5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4

7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7

5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8

8.2
8.2
8.2
8.2
8.2
8.2
8.2
8.2
8.2
8.2
8.2
8.2
8.2
8.2
8.2
8.2

5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9

8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.5
8.4

6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
5.9
5.8

9.8
9.8
9.8
9.8
9.8
9.8
9.8
9.8
9.7
9.4
9.3
9.2
9.0
8.9
8.7
8.5

6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.3
6.1
6.1
5.9
5.8
5.7
5.6
5.5

10.8
10.6
10.5
10.4
10.2
10.1
10.0
9.9
9.7
9.6
9.5
9.3
9.2
9.0
8.9
8.8

6.3
6.2
6.1
6.1
6.0
5.9
5.8
5.8
5.7
5.6
5.5
5.4
5.4
5.3
5.2
5.1

10.6

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2

6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3

8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5

6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.9

9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9

7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5

10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6

7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6

11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.0
10.8

7.9
7.9
7.9
7.9
7.9
7.9
7.9
7.9
7.9
7.9
7.9
7.9
7.9
7.9
7.7
7.5

12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.5
12.2
12.1
11.9
11.7
11.4
11.2
11.0

8.2
8.2
8.2
8.2
8.2
8.2
8.2
8.2
8.1
7.9
7.8
7.7
7.6
7.4
7.3
7.1

13.9
13.7
13.6
13.4
13.2
13.0
12.9
12.8
12.6
12.4
12.2
12.0
11.8
11.7
11.5
11.3

8.1
8.0
7.9
7.8
7.7
7.6
7.6
7.5
7.3
7.3
7.1
7.0
6.9
6.8
6.7
6.6

Capacity
Index

Outdoor
air temp.
(DB, C)

Notes:
TC: Total Capacity(kW)

3-16

30
22
TC SHC
kW
kW

32
24
TC SHC
kW kW

SHC: Sensible Heat Capacity(kW)

Indoor unit

Ceiling Cassette 4-way

Cooling capacity

Capacity
Index

14.1

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

20
14
TC SHC
kW kW

23
16
TC SHC
kW kW

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

30
22
TC SHC
kW
kW

32
24
TC SHC
kW kW

8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5

9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3

11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
13.2
13.2
13.2
13.2
13.2
13.2
13.2
13.2
13.2
13.2
13.2
13.2
13.2
13.2
13.2
13.2

14.7
14.7
14.7
14.7
14.7
14.7
14.7
14.7
14.5
14.1
14.0
13.8
13.5
13.3
13.0
12.8
16.9
16.9
16.9
16.9
16.9
16.9
16.9
16.9
16.6
16.2
16.1
15.8
15.5
15.2
14.9
14.7

16.2
15.9
15.8
15.6
15.3
15.1
15.0
14.8
14.6
14.4
14.2
14.0
13.7
13.5
13.4
13.1
18.5
18.3
18.1
17.8
17.6
17.3
17.2
17.0
16.7
16.5
16.3
16.0
15.8
15.5
15.3
15.1

Notes:
TC: Total Capacity(kW)

Ceiling Cassette 4-way

7.3
7.3
7.3
7.3
7.3
7.3
7.3
7.3
7.3
7.3
7.3
7.3
7.3
7.3
7.3
7.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3

8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
9.2
9.2
9.2
9.2
9.2
9.2
9.2
9.2
9.2
9.2
9.2
9.2
9.2
9.2
9.2
9.2

8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0

12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
14.1
14.1
14.1
14.1
14.1
14.1
14.1
14.1
14.1
14.1
14.1
14.1
14.1
14.1
14.1
14.1

8.9
8.9
8.9
8.9
8.9
8.9
8.9
8.9
8.9
8.9
8.9
8.9
8.9
8.9
8.9
8.9
10.2
10.2
10.2
10.2
10.2
10.2
10.2
10.2
10.2
10.2
10.2
10.2
10.2
10.2
10.2
10.2

13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
12.8
12.5
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
14.7
14.4

9.1
9.1
9.1
9.1
9.1
9.1
9.1
9.1
9.1
9.1
9.1
9.1
9.1
9.1
8.9
8.7
10.5
10.5
10.5
10.5
10.5
10.5
10.5
10.5
10.5
10.5
10.5
10.5
10.5
10.5
10.2
10.0

9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.4
9.2
9.1
8.9
8.8
8.6
8.4
8.3
10.9
10.9
10.9
10.9
10.9
10.9
10.9
10.9
10.8
10.5
10.4
10.2
10.0
9.9
9.7
9.5

9.4
9.3
9.2
9.1
9.0
8.8
8.8
8.6
8.5
8.4
8.3
8.2
8.0
7.9
7.8
7.7
10.8
10.7
10.6
10.4
10.3
10.1
10.1
9.9
9.8
9.6
9.5
9.4
9.2
9.1
8.9
8.8

SHC: Sensible Heat Capacity(kW)

Indoor unit

3-17

Cassette 4-way

12.3

Outdoor
air temp.
(DB, C)

Cassette 4-way

6.2 Heating Capacity


Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

1.6

2.2

2.8

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7
-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7
-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

Heating capacity
Indoor air temp. (DB, C)

16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

kW

kW

kW

kW

kW

kW

1.2
1.2
1.3
1.4
1.5
1.5
1.5
1.6
1.6
1.7
1.8
1.9
2.0
2.0
2.1
2.1
2.1
2.1
2.1
1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.3
2.4
2.5
2.6
2.8
2.8
2.9
2.9
2.9
2.9
2.9
2.1
2.2
2.3
2.5
2.6
2.7
2.8
2.8
2.9
3.0
3.2
3.4
3.6
3.6
3.7
3.7
3.7
3.7
3.7

1.2
1.2
1.3
1.4
1.5
1.5
1.5
1.6
1.6
1.7
1.8
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.3
2.4
2.5
2.6
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.9
3.0
3.2
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

1.2
1.2
1.3
1.2
1.3
1.4
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.7
1.7
1.8
1.7
1.8
1.9
1.9
2.0
2.0
2.1
2.2
2.3
2.4
2.5
2.5
2.5
2.5
2.5
2.5
2.1
2.2
2.3
2.2
2.3
2.4
2.5
2.5
2.6
2.7
2.8
3.0
3.1
3.2
3.2
3.2
3.2
3.2
3.2

1.2
1.2
1.3
1.4
1.4
1.5
1.5
1.6
1.6
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.2
2.3
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.8
3.0
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1

1.2
1.2
1.3
1.4
1.4
1.5
1.5
1.6
1.6
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.2
2.3
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.8
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0

1.2
1.2
1.3
1.4
1.4
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.7
1.7
1.8
1.9
2.0
2.1
2.1
2.1
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.1
2.2
2.3
2.4
2.6
2.7
2.7
2.7
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8

Notes:
TC: Total Capacity(kW)

3-18

Indoor unit

Ceiling Cassette 4-way

Heating capacity
Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

4.5

5.6

16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

kW

kW

kW

kW

kW

kW

2.7
2.8
2.9
3.1
3.2
3.4
3.4
3.5
3.6
3.8
4.0
4.2
4.4
4.5
4.6
4.6
4.6
4.6
4.6
3.4
3.5
3.7
3.9
4.1
4.3
4.3
4.4
4.6
4.8
5.0
5.3
5.6
5.6
5.8
5.8
5.8
5.8
5.8
4.2
4.3
4.6
4.9
5.1
5.4
5.4
5.5
5.7
6.0
6.2
6.6
7.0
7.1
7.2
7.2
7.2
7.2
7.2

2.7
2.8
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.8
4.0
4.2
4.3
4.3
4.3
4.3
4.3
4.3
4.3
3.4
3.5
3.7
3.8
4.1
4.3
4.3
4.4
4.6
4.8
5.0
5.3
5.4
5.4
5.4
5.4
5.4
5.4
5.4
4.2
4.3
4.6
4.8
5.1
5.4
5.4
5.5
5.7
6.0
6.2
6.6
6.7
6.7
6.7
6.7
6.7
6.7
6.7

2.7
2.8
2.9
2.7
2.9
3.0
3.1
3.2
3.3
3.4
3.5
3.7
3.9
4.0
4.0
4.0
4.0
4.0
4.0
3.4
3.5
3.7
3.4
3.6
3.8
3.9
4.0
4.1
4.3
4.4
4.6
4.9
5.0
5.0
5.0
5.0
5.0
5.0
4.2
4.3
4.6
4.3
4.5
4.8
4.9
5.0
5.1
5.4
5.5
5.8
6.2
6.3
6.3
6.3
6.3
6.3
6.3

2.6
2.8
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.7
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.3
3.5
3.7
3.8
4.0
4.3
4.3
4.4
4.4
4.6
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.2
4.3
4.6
4.8
5.0
5.4
5.4
5.5
5.6
5.8
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1

2.6
2.7
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.7
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.3
3.4
3.7
3.8
4.0
4.2
4.3
4.4
4.4
4.6
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.2
4.3
4.6
4.8
5.0
5.3
5.4
5.5
5.6
5.8
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9

2.6
2.7
2.9
3.0
3.2
3.4
3.4
3.4
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.3
3.4
3.6
3.8
4.0
4.2
4.3
4.3
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.2
4.3
4.5
4.8
5.0
5.3
5.4
5.4
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7
-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7
-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

Cassette 4-way

3.6

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

Indoor air temp. (DB, C)

Notes:
TC: Total Capacity(kW)

Ceiling Cassette 4-way

Indoor unit

3-19

Cassette 4-way

Heating capacity
Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

7.1

8.2

10.6

Indoor air temp. (DB, C)


16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

kW

kW

kW

kW

kW

kW

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7
-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

5.4
5.5
5.8
6.2
6.5
6.8
6.9
7.0
7.3
7.6
7.9
8.4
8.9
9.0
9.2
9.2
9.2
9.2
9.2
6.2
6.3
6.7
7.1
7.5
7.8
7.9
8.1
8.4
8.7
9.1
9.7
10.2
10.4
10.6
10.6
10.6
10.6
10.6

5.4
5.5
5.8
6.1
6.5
6.8
6.9
7.0
7.3
7.6
7.9
8.4
8.6
8.6
8.6
8.6
8.6
8.6
8.6
6.2
6.3
6.7
7.0
7.5
7.8
7.9
8.1
8.4
8.7
9.1
9.7
9.8
9.8
9.8
9.8
9.8
9.8
9.8

5.4
5.5
5.8
5.5
5.8
6.0
6.2
6.3
6.5
6.8
7.0
7.4
7.8
8.0
8.0
8.0
8.0
8.0
8.0
6.2
6.3
6.7
6.3
6.6
7.0
7.1
7.3
7.5
7.8
8.1
8.5
9.0
9.2
9.2
9.2
9.2
9.2
9.2

5.3
5.5
5.8
6.1
6.4
6.8
6.9
7.0
7.1
7.4
7.7
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
6.1
6.3
6.7
7.0
7.4
7.8
7.9
8.1
8.2
8.5
8.9
8.9
8.9
8.9
8.9
8.9
8.9
8.9
8.9

5.3
5.4
5.8
6.1
6.4
6.7
6.9
7.0
7.1
7.4
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
6.1
6.3
6.7
7.0
7.4
7.7
7.9
8.1
8.2
8.5
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6

5.3
5.4
5.8
6.1
6.4
6.7
6.8
6.8
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
6.1
6.3
6.6
7.0
7.4
7.7
7.8
7.9
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

8.0
8.2
8.7
9.2
9.6
10.1
10.2
10.5
10.8
11.3
11.8
12.5
13.2
13.4
13.7
13.7
13.7
13.7
13.7

8.0
8.2
8.7
9.0
9.6
10.1
10.2
10.5
10.8
11.3
11.8
12.5
12.7
12.7
12.7
12.7
12.7
12.7
12.7

8.0
8.2
8.7
8.2
8.6
9.0
9.2
9.4
9.7
10.1
10.4
11.0
11.6
11.9
11.9
11.9
11.9
11.9
11.9

7.9
8.2
8.7
9.0
9.5
10.1
10.2
10.5
10.6
11.0
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5

7.9
8.1
8.7
9.0
9.5
10.0
10.2
10.5
10.6
11.0
11.2
11.2
11.2
11.2
11.2
11.2
11.2
11.2
11.2

7.9
8.1
8.6
9.1
9.5
10.0
10.1
10.2
10.4
10.4
10.4
10.4
10.4
10.4
10.4
10.4
10.4
10.4
10.4

Notes:
TC: Total Capacity(kW)

3-20

Indoor unit

Ceiling Cassette 4-way

Heating capacity
Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

Indoor air temp. (DB, C)


16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

kW

kW

kW

kW

kW

12.3

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

9.2
9.5
10.1
10.6
11.2
11.7
11.9
12.1
12.6
13.1
13.7
14.5
15.3
15.5
15.9
15.9
15.9
15.9
15.9

9.2
9.5
10.1
10.5
11.2
11.7
11.9
12.1
12.6
13.1
13.7
14.5
14.8
14.8
14.8
14.8
14.8
14.8
14.8

9.2
9.5
10.1
9.5
10.0
10.4
10.7
10.9
11.3
11.7
12.1
12.8
13.5
13.8
13.8
13.8
13.8
13.8
13.8

9.1
9.5
10.1
10.5
11.0
11.7
11.9
12.1
12.2
12.8
13.3
13.4
13.4
13.4
13.4
13.4
13.4
13.4
13.4

9.1
9.4
10.1
10.5
11.0
11.6
11.9
12.1
12.2
12.8
13.0
13.0
13.0
13.0
13.0
13.0
13.0
13.0
13.0

9.1
9.4
9.9
10.5
11.0
11.6
11.7
11.8
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1

14.1

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

10.7
11.0
11.6
12.2
12.9
13.5
13.7
14.0
14.5
15.1
15.7
16.7
17.7
17.9
18.3
18.3
18.3
18.3
18.3

10.7
11.0
11.6
12.1
12.9
13.5
13.7
14.0
14.5
15.1
15.7
16.7
17.0
17.0
17.0
17.0
17.0
17.0
17.0

10.7
11.0
11.6
10.9
11.5
12.0
12.3
12.6
13.0
13.5
13.9
14.7
15.5
15.9
15.9
15.9
15.9
15.9
15.9

10.5
11.0
11.6
12.1
12.7
13.5
13.7
14.0
14.1
14.7
15.3
15.4
15.4
15.4
15.4
15.4
15.4
15.4
15.4

10.5
10.8
11.6
12.1
12.7
13.4
13.7
14.0
14.1
14.7
14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.9

10.5
10.8
11.4
12.1
12.7
13.4
13.5
13.6
13.9
13.9
13.9
13.9
13.9
13.9
13.9
13.9
13.9
13.9
13.9

Notes:
TC: Total Capacity(kW)

Ceiling Cassette 4-way

Indoor unit

3-21

Cassette 4-way

kW
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

7. Air Velocity and Temperature Distribution(Reference Data)


ARNU05GTR*2, ARNU07GTR*2, ARNU09GTR*2
Cassette 4-way

Cooling

Heating

Discharge angle: 40

Discharge angle: 50

Air velocity [m/s]

Air velocity [m/s]


2.7m

2.7m
2.0

2.0

2.0

1.5
1.0

1.5
1.0

2m

2.0
1.5

1.5
1.0

2.5m

1.5m

0m

1.5m

0m
2.5m

1.0
0.5

0.5

1m

0.5

0.5

2.5m

2m

1.5m

1m

0m

1.5m

0m
2.5m

Temperature [C]

Temperature [C]

2.7m

2.7m
33

2m

18

18
20

20

22

21

21 2m
27

18

24

27

18
24

24

1m

22

33

1m

24

2.5m

1.5m

0m

1.5m

0m
2.5m

2.5m

1.5m

0m

1.5m

0m
2.5m

ARNU12GTR*2
Cooling

Heating

Discharge angle: 40

Discharge angle: 50
Air velocity [m/s]

Air velocity [m/s]

2.7m

2.7m
2.0

2.0
1.5

2.0

2m
1.5

2.0
1.5

1.0
1.0

1.0

0.5

2.5m

2m

1.5
1.0

0.5

1m

1m

0.5

0.5

1.5m

0m

1.5m

0m
2.5m

2.5m

1.5m

0m

0m
2.5m

1.5m

Temperature [C]

Temperature [C]

2.7m

2.7m
18

33

18

20

2m

20

22

33

30
24

22

2m

30

27

27

24

21

21

1m

1m
24

2.5m

3-22

1.5m

24

0m

1.5m

0m
2.5m

2.5m

1.5m

Indoor unit

0m

1.5m

0m
2.5m

Ceiling Cassette 4-way

ARNU15GTQ*2
Cooling

Heating

Discharge angle: 40

Discharge angle: 50

Air velocity [m/s]

Air velocity [m/s]

2.7m

2.7m
2.0

2.0

2.0

1.0

0.5
3m

1m

1m

0m

1m

2m

0.5

0.5

3m

4m

0m

4m

3m

1m

1.0

1.0

0.5

2m

1.5

1.5

1.0

4m

2m

2m
1.5

2m

1m

0m

1m

2m

3m

4m

Temperature [C]

Temperature [C]

2.7m

2.7m
18

18
20

20

33

33

2m

2m
22

22

21

24

24

1m

27

24

24

3m

21

1m
27

4m

0m

2m

1m

0m

1m

2m

3m

4m

0m

4m

3m

2m

1m

0m

1m

2m

3m

4m

0m

ARNU18GTQ*2
Cooling

Heating

Discharge angle: 40

Discharge angle: 50

Air velocity [m/s]

Air velocity [m/s]

2.7m

2.7m
2.0

2.0

2.0

1.5

2m

1.0

4m

3m

2m

1.5

1.5
1m

1.0

0.5
0m

1m

3m

4m

0m

4m

3m

2m

1m

1.0

0.5

2m

2m

1.5

1.0

0.5
1m

2.0

0.5

1m

0m

1m

2m

3m

4m

Temperature [C]

Temperature [C]

2.7m

2.7m
18
20

18

22

33

20

2m

2m

2m

30

21

22

24

3m

33

30

1m

4m

0m

21
24

27

27

1m

24

24

1m

0m

Ceiling Cassette 4-way

1m

2m

3m

4m

0m

4m

3m

2m

Indoor unit

1m

0m

1m

2m

3m

4m

0m

3-23

Cassette 4-way

1.5

2.0

ARNU24GTP*2
Cassette 4-way

Cooling

Heating

Discharge angle: 40

Discharge angle: 50

Air velocity [m/s]

Air velocity [m/s]

2.0

2.0

2.7m

2.7m

2m

2m
2.0

1.5

1.5

3m

2m

1m

0m

1m

3m

4m

0m

4m

2m

0.5

1m

0m

1m

2m

3m

4m

0m

Temperature [C]

18
20
22

2.7m

2.7m

18
20
22

2m

23

24

2m

1m

0m

1m

2m

3m

4m

0m

4m

30

2m
22

22

3m

1m

24

24

27

23

24

33

33
30

1m

3m

3m

1m

1.0

0.5

2m

Temperature [C]

4m

2.0

1.0

1.0

1.0
4m

1m

2m

1m

27

0m

1m

2m

3m

4m

0m

ARNU28GTP*2
Cooling

Heating

Discharge angle: 40

Discharge angle: 50

Air velocity [m/s]

Air velocity [m/s]

2.7m
2.0

2m

2.0

1.0

1.0

1.0

2m

2m
1.5

1m

1.5

1.0
3m

2.7m

3.0
2.0

1.5

1m

1.5

4m

3.0
2.0

2.5

2.5

1m

0m

1m

2m

3m

4m

0m

0.5

4m

3m

2m

0.5

1m

0m

1m

2m

3m

4m

Temperature [C]

Temperature [C]

2.7m

2.7m
18

33

18

33

2m

2m
21
22

22
23

4m

3-24

3m

2m

0m

23

1m

0m

24

1m

1m

2m

3m

4m

0m

30

30

3m

2m

Indoor unit

24

1m

27

4m

21

1m

0m

27
1m

2m

3m

4m

0m

Ceiling Cassette 4-way

ARNU36GTN*2
Cooling

Heating

Discharge angle: 40

Discharge angle: 50

Air velocity [m/s]

Air velocity [m/s]

3.0
2.5
2.0

2.7m

3.0
2.5
2.0

2m

1.0
5m

4m

3m

1m

0m

1m

2m

4m

0m
5m

3m

2m

1.0

1m

2.7m

0m

1m

2m

3m

4m

0m
5m

22

23

1m

0m

2m

1m

2m

3m

4m

0m
5m

30

24
22

1m
23

2m

33

2m

20

22

2.7m

33

18

20

3m

4m

1m

Temperature [C]

18

4m

5m

2m

2.0

1.0

3m

Temperature [C]

5m

2.0

1.0
1m

2m

2.7m

3.5
3.0
2.5

30

27

5m

4m

3m

2m

1m

24
22

1m

4m

0m
5m

27

0m

1m

2m

3m

ARNU42GTM*2
Cooling

Heating

Discharge angle: 40

Discharge angle: 50

Air velocity [m/s]

Air velocity [m/s]

3.2m

3.2m
4.0

4.0

4.0
3.0

3.0

3.0

2m

3.0

4.0

2m

1m

5m

4m

3m

1m
2.0

2.0
1.0

2.0
1.0
1m

2m

0m

1m

2m

2.0

1.0

3m

4m

0m
5m

5m

4m

3m

2m

1.0

1m

0m

1m

2m

3m

4m

Temperature [C]

Temperature [C]
3.2m

3.2m

2m

20

33

33

18

18

24

20

30

22

22

4m

3m

2m

1m

0m

Ceiling Cassette 4-way

1m

2m

3m

30
22

27

24

24

4m

0m
5m

5m

4m

2m

24
22

1m

5m

0m
5m

3m

2m

Indoor unit

1m

1m

27

0m

1m

2m

3m

4m

0m
5m

3-25

Cassette 4-way

1.5

1.5

3.5
3.0
2.5

ARNU48GTM*2
Cassette 4-way

Cooling

Heating

Discharge angle: 40

Discharge angle: 50

Air velocity [m/s]

Air velocity [m/s]

3.2m
4.0

1.0
4m

3m

2m

1m

0m

1m

2m

2m

3.0

3.0

1m

2.0
1.0

2.0

4.0

2m

3.0

3.0

5m

3.2m
4.0

4.0

1m
2.0

2.0

1.0

3m

4m

0m
5m

5m

4m

3m

2m

1m

1.0

0m

1m

2m

3m

4m

0m
5m

Temperature [C]

Temperature [C]
3.2m

3.2m
33

18

18

2m

20

20

33

2m
22

24

22

24

1m
22
24

5m

4m

3-26

24

3m

2m

1m

1m

0m

1m

2m

3m

30

30
27

22

4m

0m
5m

5m

4m

3m

2m

Indoor unit

1m

27

0m

1m

2m

3m

4m

0m
5m

Ceiling Cassette 4-way

8. Electric Characteristicss
Units
Model

Type

Power Supply
Hz

Volts

Voltage Range MCA

IFM

Input(W)

MFA

kW

FLA

Cooling Heating

TR

1.25

15

0.043

0.2

30

30

ARNU07GTR*2

TR

1.25

15

0.043

0.2

30

30

ARNU09GTR*2

TR

1.25

15

0.043

0.2

30

30

ARNU12GTR*2

TR

1.25

15

0.043

0.2

30

30

ARNU15GTQ*2

TQ

1.25

15

0.043

0.2

30

30

ARNU18GTQ*2

TQ

1.25

15

0.043

0.2

30

30

1.22

15

0.03

0.17

33

33

50

220~240

MAX : 264
MIN:198

ARNU24GTP*2

TP

ARNU28GTP*2

TP

1.22

15

0.03

0.17

33

33

ARNU36GTN*2

TN

1.81

15

0.135

0.64

144

144

ARNU42GTM*2

TM

1.81

15

0.135

0.64

144

144

ARNU48GTM*2

TM

1.81

15

0.135

0.64

144

144

ARNU05GTR*2

TR

1.25

15

0.043

0.2

30

30

ARNU07GTR*2

TR

1.25

15

0.043

0.2

30

30

ARNU09GTR*2

TR

1.25

15

0.043

0.2

30

30

ARNU12GTR*2

TR

1.25

15

0.043

0.2

30

30

ARNU15GTQ*2

TQ

1.25

15

0.043

0.2

30

30

ARNU18GTQ*2

TQ

1.25

15

0.043

0.2

30

30

ARNU24GTP*2

TP

1.22

15

0.03

0.17

33

33

ARNU28GTP*2

TP

1.22

15

0.03

0.17

33

33

ARNU36GTN*2

TN

1.81

15

0.135

0.64

144

144

ARNU42GTM*2

TM

1.81

15

0.135

0.64

144

144

ARNU48GTM*2

TM

1.81

15

0.135

0.64

144

144

60

220

MAX : 242
MIN:198

Symbols:
MCA : Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
IFM : Indoor Fan Motor
Note :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA + 1
MFA 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the larger value on the MCA.
5. Instead of fuse, use Circuit Breaker.

Ceiling Cassette 4-way

Indoor unit

3-27

Cassette 4-way

ARNU05GTR*2

9. Sound Levels

Cassette 4-way

Overall
Notes:
- Sound measured at 1.5m below the center of the unit.
- Data is valid at free field condition
- Data is valid at nominal operating condition
- Reference accoustic pressure OdB = 20Pa
- Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment is installed.

Ceiling
1.5m

Model
ARNU05GTR*2
ARNU07GTR*2
ARNU09GTR*2
ARNU12GTR*2
ARNU15GTQ*2
ARNU18GTQ*2

H
36
36
36
36
37
38

Sound Level dB(A)


L
M
33
35
33
35
34
35
34
35
35
36
36
37

Sound Level dB(A)


L
M
35
31
38
32
40
39
44
42
47
45

Model
H
38
39
43
47
48

ARNU24GTP*2
ARNU28GTP*2
ARNU36GTN*2
ARNU42GTM*2
ARNU48GTM*2

Sound Pressure Level


ARNU07GTR*2

ARNU09GTR*2
80

70

70

70

NC-65

60

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
NC-25

20
Approximate
Hearing
Threshold
10
63

3-28

NC-60

125 250 500 1000 2000 4000 8000


Octave Band Center Frequency (Hz)

NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
NC-25

20
Approximate
Hearing
Threshold

NC-20
NC-15

NC-65

60

10
63

Octave Band Sound Pressure Level (dB re 20Pa )

80

Octave Band Sound Pressure Level (dB re 20Pa )

Octave Band Sound Pressure Level (dB re 20Pa )

ARNU05GTR*2
80

NC-60

125 250 500 1000 2000 4000 8000


Octave Band Center Frequency (Hz)

Indoor unit

NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
NC-25

20
Approximate
Hearing
Threshold

NC-20
NC-15

NC-65

60

10
63

NC-20
NC-15

125 250 500 1000 2000 4000 8000


Octave Band Center Frequency (Hz)

Ceiling Cassette 4-way

ARNU15GTQ*2
70

70

NC-65

60

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
NC-25
Approximate
Hearing
Threshold
63

NC-60

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
NC-25

20
Approximate
Hearing
Threshold

NC-15

125 250 500 1000 2000 4000 8000


Octave Band Center Frequency (Hz)

NC-55

50

NC-20

10

NC-65

60

63

NC-55
NC-50
NC-45
NC-40
NC-35

30

NC-30
20

63

250

500

NC-15
1000 2000 4000 8000

NC-65

60

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30

10

NC-25
Approximate
Hearing
Threshold
63

NC-30
NC-25
NC-20
NC-15

10
63

125 250 500 1000 2000 4000 8000


Octave Band Center Frequency (Hz)

70

125

250

500

NC-15
1000 2000 4000 8000

ARNU42GTM*2

NC-65

60

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
20

NC-20

10

NC-25
Approximate
Hearing
Threshold
63

125

NC-20

250

500

NC-15
1000 2000 4000 8000

Octave Band Center Frequency (Hz)

Octave Band Center Frequency (Hz)

ARNU48GTM*2

80

80

70

NC-65

60

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
NC-25

20
Approximate
Hearing
Threshold
63

125

Octave Band Sound Pressure Level (dB re 20Pa )

Octave Band Sound Pressure Level (dB re 20Pa )

NC-35

30

ARNU36GTN*2

70

NC-20

125

NC-40

80

Octave Band Center Frequency (Hz)

10

NC-15

20

NC-25
Approximate
Hearing
Threshold

NC-45

40

Approximate
Hearing
Threshold

Octave Band Sound Pressure Level (dB re 20Pa )

NC-60

Octave Band Sound Pressure Level (dB re 20Pa )

NC-65

40

NC-50

ARNU28GTP*2

70

50

NC-55

50

20

80

60

NC-60

125 250 500 1000 2000 4000 8000


Octave Band Center Frequency (Hz)

ARNU24GTP*2

NC-65

60

NC-20

10

80

10

Octave Band Sound Pressure Level (dB re 20Pa )

70
Octave Band Sound Pressure Level (dB re 20Pa )

80

20

Octave Band Sound Pressure Level (dB re 20Pa )

ARNU18GTQ*2

80

70

NC-60

250

500

Octave Band Center Frequency (Hz)

Ceiling Cassette 4-way

NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
NC-25

20
Approximate
Hearing
Threshold

NC-20
NC-15
1000 2000 4000 8000

NC-65

60

NC-20
NC-15

10
63

125

250

500

1000 2000 4000 8000

Octave Band Center Frequency (Hz)

Indoor unit

3-29

Cassette 4-way

Octave Band Sound Pressure Level (dB re 20Pa )

ARNU12GTR*2
80

Please read this instruction sheet completely before installing the product.
When the power cord is damaged, replacement work shall be performed by authorized personnel only.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Anti-bacteria filter

Air
Intake

TEMP

Remote Controller

Air Outlet

Required Parts

Required Tools

Connecting cable
Pipes: Gas side
Liquid side
Hanging Bolt
(W 3/8 or M10 length 650mm)
Insulated drain hose
Additional Drain hose

Level
Screw driver
Electric drill
Hole core drill
Flaring Tool set
Torque Wrenches
Hexagonal Wrench
Gas-leak detector
Thermometer

3-30

50 or
more

Ceiling Board

50 or
more

30 or less

Ceiling
Ceiling Board

Above 250
360 or less

There should not be any heat source or steam near the


unit.
There should not be any obstacles to the air circulation.
A place where air circulation in the room will be good.
A place where drainage can be easily obtained.
A place where noise prevention is taken into consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the wall,
ceiling, or other obstacles.
The indoor unit must have sufficient maintenance
space.

30 or more

10.1 Selection of the best location

100
or more

Cassette 4-way

10. Installation

Unit:cm
Floor

Indoor unit

Ceiling Cassette 4-way

10.2 Ceiling opening dimensions and hanging bolt location


The dimensions of the paper pattern for installation are the same as those of the ceiling opening dimensions.

Ceiling
Ceiling board

Level gauge

TM/TN/TP Chassis
875(Ceiling opening)

517

461

CAUTION
This air-conditioner uses a drain pump.
Install the unit horizontally using a level gauge.
During the installation, care should be taken not to
damage electric wires.

875(Ceiling opening)

517

Unit:mm

684(Hanging bolt)

840 Unit size


840 Unit size

671

319

570

585~660(Ceiling opening)

787(Hanging bolt)

570
523

Cassette 4-way

TQ/TR Chassis
585~660(Ceiling opening)

Unit:mm

Select and mark the position for fixing bolts and piping hole.
Decide the position for fixing bolts slightly tilted to
the drain direction after considering the direction of
drain hose.
Drill the hole for anchor bolt on the wall.

NOTE:
Avoid the following installation location.
1. Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated.
These may cause heat exchange efficiency reduction, or water drops, drain pump mal-function.
In these cases, take the following actions;
Make sure that ventilation fan is enough to cover all noxious gases from this place.
Ensure enough distance from the cooking room to install the air conditioner in such a place where it may not suck oily steam.
Air conditioner

Take enough
distance
Use the ventilation fan
for smoke-collecting
hood with sufficient
capacity.
Cooking table

2. Avoid installng air conditioner in such places where cooking oil or iron powder is generated.
3. Avoid places where inflammable gas is generated.
4. Avoid place where noxious gas is generated.
5. Avoid places near high frequency generators.

Ceiling Cassette 4-way

Indoor unit

3-31

Ceiling

Cassette 4-way

Nut
(W3/8 or M10)

Flat washer for M10


(accessory)
Ceiling board

150mm

Keep the length of the bolt


from the bracket to 40mm

Hanging bolt
(W3/8 or M10)

Air Conditioner body

Ceiling board
Keep the length of 15~18mm
between the air conditioner bottom
surface and the ceiling surface

Flat washer for M10


(accessory)
Nut
(W3/8 or M10)

Set screw of
paper model (4 pieces)
Paper model
for installation

The following parts are locally purchased.


Hanging Bolt - W 3/8 or M10
Nut
- W 3/8 or M10
Spring Washer - M10
Plate Washer - M10

Open the ceiling board


along the outer edge of the
paper model

CAUTION
Tighten the nut and bolt to prevent the unit
from falling.

10.3 Wiring Connection


Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit
respectively.
Remote
control cord

Indoor
power cord

TR/TQ Chassis
Terminal Block Indoor
1(L)

2(N)

SODU

INTERNET DRY1 DRY2 GND 12V

IDU
-

Outdoor
Unit

INDOOR POWER INPUT

TM/TN/TP Chassis
Terminal Block Indoor
1(L) 2(N) 3(L) 4(N) 5(A) 5(B)

POWER
INPUT

SODU
B

INTERNET DRY1 DRY2 GND 12V

IDU
-

Outdoor
Unit

TO AIR
FRESH KIT

WARNING
Make sure that the screws of the terminal are not loose.

3-32

Indoor unit

Ceiling Cassette 4-way

10.4 Installation of Decoration Panel


Before installing the decoration panel,
always remove the paper template.

The decoration panel has its installation


direction.

Piping side
Air conditioner unit

Control box cover


Decoration panel fixing screws
(hexagon M5 screws)
Temporally fitting at 2 places
(Tightening about 10mm)

Louver motor

Decoration panel

Display
Lead wire for
louver motor and
display

Decoration panel fixing screws


(Hexagon M5 screw)

CAUTION
Inlet Grille

Install certainly the decoration


panel.
Cool air leakage causes
sweating.

Good example

Bad example
Air conditioner
unit

Air conditioner unit


Air

Cool air leakage


(no good)

Water drops fall.


Ceiling
board
Decoration panel
Fit the insulator (this part) and
be careful for cool air leakage

Ceiling Cassette 4-way

Indoor unit

Ceiling
board
Decoration
panel

3-33

Cassette 4-way

1. Temporarily fix two decoration panel fixing screws (hexagon M5 screw) on the unit body. (Tighten by
amount 10mm in length.)
The fixing screws (hexagon M5 screw) are included in the indoor unit box.
2. Remove the air inlet grille from the decoration panel. (Remove the hook for the air inlet grille cord.)
3. Hook the decoration panel key hole (
) on the screws fixed in step above, and slide the panel so
that the screws reach the key hole edge.
4. Retighten completely two temporarily fixed screws and other two screws. (Total 4 screws)
5. Connect the louver motor connector and display connector.
6. After tightening these screws, install the air inlet grille (including the air filter).

Drain piping must have down-slope (1/50 to 1/100): be sure not to provide up-and-down slope to prevent reversal flow.
During drain piping connection, be careful not to exert extra force on the
drain port on the indoor unit.
The outside diameter of the drain connection on the indoor unit is 32mm.
Piping material: Polyvinyl chloride pipe inner
diometes 25mm and pipe fittings

Upward
routing
not allowed

Pipe clamp
Indoor unit

Maintenance
drain port

Be sure to install heat insulation on the drain piping.

1/50~1/100

Heat insulation material: Polyethylene foam with


thickness more than 8 mm.

MAX 700mm

Drain test
The air conditioner uses a drain pump to drain water.
Use the following procedure to test the drain pump operation:
Feed water

Flexible drain hose


(accessory)
Main
drain pipe

Drain Pump

Drain
port

Glue the joint

Drain hose connection


Use the clip (accessory)

Connect the main drain pipe to the exterior and leave it provisionally until the test comes to an end.
Feed water to the flexible drain hose and check the piping
for leakage.
Be sure to check the drain pump for normal operating and
noise when electrical wiring is complete.
When the test is complete, connect the flexible drain hose to
the drain port on the indoor unit.

Drain pan

CAUTION

Max 300mm

The supplied flexible drain hose should not be strained.


A strained hose may cause leakage of water.

Hanger
distance
1~15m

Metal
clamp
Flexible drain hose

Hanger Bracket
1/50~1/100 slope
Max 700mm

Cassette 4-way

10.5 Indoor Unit Drain Piping

Insulation

CAUTION
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have separate power specially for the air conditioner. As for the method of wiring, follow the circuit diagram pasted on the inside of
control box cover.
2) Provide a circuit breaker switch between power source and the unit.
3) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the unit is subjected during
the course of transportation. Check them and make sure that they are all tightly fastened. (If they are loose, it could give rise to burn-out of the
wires.)
4) Confirm the specification of power source
5) Confirm that electrical capacity is sufficient.
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate.
7) Confirm that the cable thickness is as specified in the power sources specification.
(Particularly note the relation between cable length and thickness.)
8) Do not install the leakage breaker in a place which is wet or moist.
Water or moist may cause short circuit.
9) The following troubles would be caused by voltage drop-down.
Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to the normal function of a overload protection device.
Proper starting power is not given to the compressor.

HAND OVER
Teach the customer the operation and maintenance procedures, using the operation manual (air filter cleaning, temperature control, etc.).

3-34

Indoor unit

Ceiling Cassette 4-way

WIRED REMOTE CONTROLLER INSTALLATION


Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.

Do not install the remote controller where it can be affected by:

TEMP

Cassette 4-way

- Drafts, or dead spots behind doors and in corners.


- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)

yes

Remote Controller

no

TEMP

Controller
Remote

TEMP

Remote Controller

5feet
(1.5meters)

no

no

Fig.1 Typical locations for remote controller

Ceiling Cassette 4-way

Indoor unit

3-35

11. Accessories

Cassette 4-way

Standard Accessories
Name

Drain hose

Clamp metal

Quantity

1 EA

2 EA

Shape

Washer for
hanging backet
8 EA

Clamp
(Tie Wrap)

Insulation for
fitting

4 EA

1 SET

for gas pipe

Bolt

(Other)

4 EA
Paper pattern for
installation
Owner's manual
Installation manual

for liquid pipe

CAUTION
Use only those accessories (Standard or optional) which have designated specifications.

3-36

Indoor unit

Ceiling Cassette 4-way

1. List of functions
2. Specifications
3. Dimensions & Gravity point
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. External Static Pressure(E.S.P) & Air Flow
8. Electric Characteristics
9. Sound Levels
10. Installation
11. Accessories

Ceiling Concealed Duct


- High Static

Indoor unit

Ceiling Concealed Duct- High Static

Ceiling Concealed Duct


(High Static)

Ceiling Concealed Duct- High Static

1. List of functions
Category

Air flow

Air purifying

Installation

Reliability

Convenience

Individual
control

Special
function kit

Function
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Wide wired remote controller
Deluxe wired remote controller
Simple wired remote controller
Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
Zone control
CTIE
Electro thermostat

ARNU07GBHA2, ARNU09GBHA2, ARNU12GBHA2, ARNU15GBHA2,


ARNU18GBHA2, ARNU24GBHA2, ARNU28GBGA2 , ARNU36GBGA2,
ARNU42GBGA2, ARNU48GBRA2, URNU76GB8A2, URNU96GB8A2
1
3/3/3
X
X
O
O
O
X
O
O
O
O(Heat recovery)
X
O(Heat pump or Cooling only)
O
O
O
O
O
O
O
Accessory
Accessory
Accessory
Accessory
X
Accessory
Accessory
-

O : Applied
X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

4-1

Indoor unit

Ceiling Concealed Duct


- High Static

2. Specifications
Type
Model

Heating Capacity
Casing
Dimensions(WxDxH) Body

mm
inch

Rows x Columns x FPI


Face Area
m2
Type
Motor Output x Number
W
Running Current
A
Air Flow Rate(H/M/L)
CMM
(High Mode-factory set)
cfm
Fan
External Static Pressure mmAq(Pa)
Air Flow Rate(H/M/L)
CMM
(Standard Mode)
cfm
External Static Pressure mmAq(Pa)
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side
mm(inch)
Pipe Connections Gas Side
mm(inch)
Drain Pipe(Internal Dia.)
mm
Net Weight
kg(lbs)
Noise Level(Sound Press, 1.5m, H/M/L) dB(A)3
Coil

Power Supply
Refrigerant Control
Power cable
Transmission cable

, V, Hz
mm2
mm2

ARNU07GBHA2
2.2
1,900
7,500
2.5
2,200
8,500
Galvanized Steel Plate
882x450x260
34.7x17.7x10.2
2x10x21
0.15
Sirocco Fan
118
0.92
8.5/7.5/6
300/265/212
8(78)
8.5/8/7.5
300/282/265
6(59)
Direct
BLDC
Microprocessor, Thermostat for cooling and heating
Foamed polystrene
Fuse
6.35(1/4)
12.7(1/2)
25.0
26(57.4)
34/33/32
1, 220 ~ 240, 50
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.25 x 2C

Ceiling Concealed Duct -High Static


ARNU09GBHA2 ARNU12GBHA2
2.8
3.6
2,400
3,100
9,600
12,300
3.2
4.0
2,800
3,400
10,900
13,600
Galvanized Steel Plate Galvanized Steel Plate
882x450x260
882x450x260
34.7x17.7x10.2
34.7x17.7x10.2
2x10x21
2x10x21
0.15
0.15
Sirocco Fan
Sirocco Fan
118
118
0.92
0.92
10/8.5/7.5
12/10/8.5
353/300/265
424/353/300
8(78)
8(78)
8.5/8/7.5
11/8.5/7.5
300/282/265
388/300/265
6(59)
6(59)
Direct
Direct
BLDC
BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene
Fuse
Fuse
6.35(1/4)
6.35(1/4)
12.7(1/2)
12.7(1/2)
25.0
25.0
26(57.4)
26(57.4)
35/34/33
37/35/34
1, 220 ~ 240, 50 1, 220 ~ 240, 50
1, 220, 60
1, 220, 60
EEV
EEV
CV1.5 x 3C
CV1.5 x 3C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Noise Level is Standard Mode
(for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dB(A))

Ceiling Concealed Duct


- High Static

Indoor unit

ARNU15GBHA2
4.5
3,900
15,400
5.0
4,300
17,100
Galvanized Steel Plate
882x450x260
34.7x17.7x10.2
2x10x21
0.15
Sirocco Fan
118
0.92
13.5/12/8.5
477/424/300
8(78)
13.5/12/11
477/424/388
6(59)
Direct
BLDC
Microprocessor, Thermostat for cooling and heating
Foamed polystrene
Fuse
6.35(1/4)
12.7(1/2)
25.0
26(57.4)
39/38/37
1, 220 ~ 240, 50
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.25 x 2C

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

4-2

Ceiling Concealed Duct- High Static

Cooling Capacity

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h

Ceiling Concealed Duct- High Static

Type
Model
Cooling Capacity

Heating Capacity

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h

Casing
Dimensions(WxDxH) Body

mm
inch

Rows x Columns x FPI


Face Area
m2
Type
Motor Output x Number
W
Running Current
A
Air Flow Rate(H/M/L)
CMM
(High Mode-factory set)
cfm
Fan
External Static Pressure mmAq(Pa)
Air Flow Rate(H/M/L)
CMM
(Standard Mode)
cfm
External Static Pressure mmAq(Pa)
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side
mm(inch)
Pipe Connections Gas Side
mm(inch)
Drain Pipe(Internal Dia.)
mm
Net Weight
kg(lbs)
Noise Level(Sound Press, 1.5m, H/M/L) dB(A)3
Coil

Power Supply
Refrigerant Control
Power cable
Transmission cable

, V, Hz
mm2
mm2

Ceiling Concealed Duct(High Static)


ARNU18GBHA2
ARNU24GBHA2
ARNU28GBGA2
5.6
7.1
8.2
4,800
6,100
7,100
19,100
24,200
28,000
6.3
8.0
9.2
5,400
6,900
8,000
21,500
27,300
31,500
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
882x450x260
882x450x260
1,182x450x298
34.7x17.7x10.2
34.7x17.7x10.2
46.5x17.7x11.7
3x10x21
3x10x21
3x12x21
0.15
0.15
0.26
Sirocco Fan
Sirocco Fan
Sirocco Fan
118
118
390
0.92
0.92
2.30
15.5/13.5/12.4
18.3/16.9/15.5
25.9/24.1/21.8
547/477/438
646/597/547
915/851/770
8(78)
8(78)
10(98)
15.3/13.6/10.3
19/16.4/14.5
25.3/21.8/17.6
540/480/364
671/579/512
893/770/622
6(59)
6(59)
8(78)
Direct
Direct
Direct
BLDC
BLDC
BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene
Foamed polystrene
Foamed polystrene
Fuse
Fuse
Fuse
6.35(1/4)
9.52(3/8)
9.52(3/8)
12.7(1/2)
15.88(5/8)
15.88(5/8)
25.0
25.0
25.0
26.5(58.4)
26.5(58.4)
38(83.8)
42.5/41/37
45/43/41
44/42/40
1, 220 ~ 240, 50
1, 220 ~ 240, 50
1, 220 ~ 240, 50
1, 220, 60
1, 220, 60
1, 220, 60
EEV
EEV
EEV
CV1.5 x 3C
CV1.5 x 3C
CV1.5 x 3C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Noise Level is Standard Mode
(for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dB(A))

4-3

Indoor unit

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

Ceiling Concealed Duct


- High Static

Cooling Capacity

Heating Capacity

Ceiling Concealed Duct(High Static)


Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h

Casing
Dimensions(WxDxH) Body

mm
inch

Rows x Columns x FPI


Face Area
m2
Type
Motor Output x Number
W
Running Current
A
Air Flow Rate(H/M/L)
CMM
(High Mode-factory set)
cfm
Fan
External Static Pressure mmAq(Pa)
Air Flow Rate(H/M/L)
CMM
(Standard Mode)
cfm
External Static Pressure mmAq(Pa)
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side
mm(inch)
Pipe Connections Gas Side
mm(inch)
Drain Pipe(Internal Dia.)
mm
Net Weight
kg(lbs)
Noise Level(Sound Press, 1.5m, H/M/L) dB(A)3
Coil

Power Supply
Refrigerant Control
Power cable
Transmission cable

, V, Hz
mm2
mm2

ARNU36GBGA2
ARNU42GBGA2
ARNU48GBRA2
10.6
12.3
14.1
9,100
10,600
12,100
36,200
42,000
48,100
11.9
13.8
15.9
10,200
11,000
13,200
40,600
43,800
51,200
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
1,182x450x298
1,182x450x298
1,230x590x380
46.5x17.7x11.7
46.5x17.7x11.7
48.4x23.2x15
3x12x21
3x12x21
3x13x19
0.26
0.26
0.38
Sirocco Fan
Sirocco Fan
Sirocco Fan
390
390
390
2.30
2.30
2.40
32.3/29/25.3
34.5/32.3/30.7
44.8/40.6/33.3
1,141/1,024/894
1,218/1,141/1,084
1,582/1,434/1,176
10(98)
10(98)
14(137)
28.4/25.3/21.8
32/28.4/27.2
44.4/39.5/33.5
1,003/894/770
1,130/1,003/961
1,568/1,395/1,183
8(78)
8(78)
10(98)
Direct
Direct
Direct
BLDC
BLDC
BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene
Foamed polystrene
Foamed polystrene
Fuse
Fuse
Fuse
9.52(3/8)
9.52(3/8)
9.52(3/8)
15.88(5/8)
15.88(5/8)
15.88(5/8)
25.0
25.0
25.0
38(83.8)
38(83.8)
53(117)
46/44/42
48/46/45
45/43/41
1, 220 ~ 240, 50
1, 220 ~ 240, 50
1, 220 ~ 240, 50
1, 220, 60
1, 220, 60
1, 220, 60
EEV
EEV
EEV
CV1.5 x 3C
CV1.5 x 3C
CV1.5 x 3C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Noise Level is Standard Mode
(for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dB(A))

Ceiling Concealed Duct


- High Static

Indoor unit

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

4-4

Ceiling Concealed Duct- High Static

Type
Model

Ceiling Concealed Duct- High Static

Ceiling Concealed Duct(High Static)


URNU76GB8A2
URNU96GB8A2
22.4
28
19,300
24,100
Cooling Capacity
76,400
95,900
25.2
31.5
21,700
27,100
Heating Capacity
86,000
107,500
Galvanized Steel Plate
Galvanized Steel Plate
Casing
1,562x688x460
1,562x688x460
mm
Dimensions(WxDxH) Body
61.5x27.1x18.1
61.5x27.1x18.1
inch
3x21x19
3x21x19
Rows
x
Columns
x
FPI
Coil
0.59
0.59
Face Area
m2
Sirocco Fan
Sirocco Fan
Type
375x2
375x2
Motor Output x Number
W
4.50
4.50
Running Current
A
64/50/50
72/64/64
Air Flow Rate(H/M/L)
CMM
2,260/1,766/1,766
2542/2,260/2,260
(High Mode-factory set)
cfm
22(216)
22(216)
Fan
External Static Pressure mmAq(Pa)
60/50/50
76/64/64
Air Flow Rate(H/M/L)
CMM
2,119/1,766/1,766
2,684/2,260/2,260
(Standard Mode)
cfm
15(147)
15(147)
External Static Pressure mmAq(Pa)
Direct
Direct
Drive
BLDC
BLDC
Motor type
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Temperature Control
Foamed polystrene
Foamed polystrene
Sound Absorbing Thermal Insulation Material
Air Filter
Fuse
Fuse
Safety Device
9.52(3/8)
9.52(3/8)
Liquid Side
mm(inch)
19.05(3/4)
22.2(7/8)
Pipe Connections Gas Side
mm(inch)
25.0
25.0
Drain Pipe(Internal Dia.)
mm
87(192)
87(192)
Net Weight
kg(lbs)
50/48/48
52/50/50
Noise Level(Sound Press, 1.5m, H/M/L) dB(A)3
1, 220 ~ 240, 50
1, 220 ~ 240, 50
Power Supply
, V, Hz
1, 220, 60
1, 220, 60
EEV
EEV
Refrigerant Control
CV1.5 x 3C
CV1.5 x 3C
Power cable
mm2
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
Transmission cable
mm2
Type
Model

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Noise Level is Standard Mode
(for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dB(A))

4-5

Indoor unit

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

Ceiling Concealed Duct


- High Static

Indoor unit

R3

7.
5

60

114

450

260

47

20

175

75

21

49

64

24

243

428

882

212

882

87
750

932

243

119

65

108

30

115

450
47

133
127
106

355

158

450

219
119

Ceiling Concealed Duct


- High Static
1
2

100

50

70

260

29

51

123 140

48
52 165

31

Air discharge
Air suction

5
6

(unit : mm)
Unit size(7k,9k,12k,18k):6.35
Unit size(24k):9.52
Unit size(7k,9k,12k,18k):12.7
Unit size(24k):15.88

Descripition

Gravity point

CHASSIS CODE: BH

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Note

Power supply connection

Drain pipe connection

Gas pipe connection

Liquid pipe connection

Name

Number

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

101

ARNU07GBHA2
ARNU09GBHA2
ARNU12GBHA2
ARNU15GBHA2
ARNU18GBHA2
ARNU24GBHA2

Ceiling Concealed Duct (High Static)

Ceiling Concealed Duct- High Static

745

3. Dimensions & Gravity point

4-6

355

224

Indoor unit

1
0

60

152

20

298

220

23

186

450

232

49

565

243

1,182

232

1,182

87
830

1,230

1,043

243

232

115

108

29

75

87

355
450
158
113

219
136

4-7

Ceiling Concealed Duct


- High Static

224

100

50

2
261

165

122 140

47
53

32

Note

(unit : mm)

Unit size(28k,36k,42k):15.88

Unit size(28k,36k,42k):9.52

Descripition

Gravity point

CHASSIS CODE: BG

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Air suction

Air discharge

5
6

Power supply connection

Drain pipe connection

Gas pipe connection

2
3

Liquid pipe connection

Name

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

102
51

Number

ARNU28GBGA2
ARNU36GBGA2
ARNU42GBGA2

Ceiling Concealed Duct (High Static)

Ceiling Concealed Duct- High Static

R6
0

60

198

312

380

25

303

50

215

621

279

1,230

241

118
1,004

1,284
1,230

279
215

120

114

90

135
190
260

115

101
83

Name

Air discharge
Air suction

4
5
6

Unit size(48k):15.88

Unit size(48k):9.52

Descripition

(unit : mm)

Gravity point

CHASSIS CODE: BR

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Note

Power supply connection

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

Gas pipe connection


Drain pipe connection

Liquid pipe connection

Number
26

ARNU48GBRA2

Ceiling Concealed Duct (High Static)

72
123
221
122
144

1,092

477
590
56
168
185
174

32

140

590

Indoor unit

Ceiling Concealed Duct- High Static

Ceiling Concealed Duct


- High Static

4-8

302

Indoor unit

460

460

688

20

440

318

293

329

819

1,562

320

1,220

1,562

1,622

1,396

329

115

688
30

222

560
64

290
161

4-9

Ceiling Concealed Duct


- High Static

358

68

18

109

58

Name

Air discharge
Air suction

3
5
6

(unit : mm)

Unit size(76k):19.05
Unit size(96k):22.2

Unit size(76k,96k):9.52

Descripition

Gravity point

CHASSIS CODE: B8

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Note

Gas pipe connection


Drain pipe connection
Power supply connection

Liquid pipe connection

Number

40
99 1

70
120

URNU76GB8A2
URNU96GB8A2

Ceiling Concealed Duct (High Static)

Ceiling Concealed Duct- High Static

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

122 60 70 64

397

4. Piping Diagrams

:Cooling
:Heating

EEV
Filter

Th3

Ceiling Concealed Duct- High Static

Heat Exchanger
Th2
Sirocco Fan

Th1

Filter

lndoor unit

Refrigerant pipe connection port diameter


[Unit: mm(inch)]

MODEL

GAS

LIQUID

ARNU07GBHA2

12.7(1/2)

6.35(1/4)

ARNU09GBHA2

12.7(1/2)

6.35(1/4)

ARNU12GBHA2

12.7(1/2)

6.35(1/4)

ARNU15GBHA2

12.7(1/2)

6.35(1/4)

ARNU18GBHA2

12.7(1/2)

6.35(1/4)

ARNU24GBHA2

15.88(5/8)

9.52(3/8)

ARNU28GBGA2

15.88(5/8)

9.52(3/8)

ARNU36GBGA2

15.88(5/8)

9.52(3/8)

ARNU42GBGA2

15.88(5/8)

9.52(3/8)

ARNU48GBRA2

15.88(5/8)

9.52(3/8)

URNU76GB8A2

19.05(3/4)

9.52(3/8)

URNU96GB8A2

22.2(7/8)

9.52(3/8)

LOC.

Description

Th1

Room thermistor

Th2

Pipe in thermistor

Th3

Pipe out thermistor

Ceiling Concealed Duct


- High Static

Indoor unit

4-10

5. Wiring Diagrams
Ceiling Concealed Duct- High Static

BH Chassis

CONNECTOR NUMBER
CN-POWER
CN-MOTOR1
CN-D/PUMP
CN-COM
CN-EEV
CN-FLOAT
CN-PIPE/IN
CN-PIPE/OUT
CN-ROOM
CN-REMO
CN-ZON
CN-DISPLAY
CN-CC

LOCATION POINT
AC Power supply
Fan motor output
Drain pump output
Communication
EEV Output
Float switch input
Suction pipe sensor
Discharge pipe sensor
Room sensor
Remote controller
Zontroller
RF Remote controller
Dry contact

Dip Switch Setting


SW3
GROUP

Off
Master

On
Slave

SW4

DRY CONTACT

Variable

Auto

SW5

EXTRA 1

Off

On

FUNCTION
AC Power line input for indoor controller
Motor output of BLDC
AC output for drain pump
Connection between indoor and outdoor
EEV Control output
Float switch sensing
Pipe in thermistor
Pipe out thermistor
Room air thermistor
Remote control line
Zone control line
RF Remote control line
Dry contact line
Remarks
Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

4-11

Indoor unit

Ceiling Concealed Duct


- High Static

BG Chassis
Ceiling Concealed Duct- High Static

CONNECTOR NUMBER
CN-POWER
CN-MOTOR1
CN-MOTOR2
CN-D/PUMP
CN-COM
CN-EEV
CN-FLOAT
CN-PIPE/IN
CN-PIPE/OUT
CN-ROOM
CN-REMO
CN-ZON
CN-DISPLAY
CN-CC

LOCATION POINT
AC Power supply
Fan motor output
Fan motor output
Drain pump output
Communication
EEV Output
Float switch input
Suction pipe sensor
Discharge pipe sensor
Room sensor
Remote controller
Zontroller
RF Remote controller
Dry contact

Dip Switch Setting


SW3
GROUP

Off
Master

On
Slave

SW4

DRY CONTACT

Variable

Auto

SW5

EXTRA 1

Off

On

FUNCTION
AC Power line input for indoor controller
Motor output of BLDC
Motor output of BLDC
AC output for drain pump
Connection between indoor and outdoor
EEV Control output
Float switch sensing
Pipe in thermistor
Pipe out thermistor
Room air thermistor
Remote control line
Zone control line
RF Remote control line
Dry contact line
Remarks
Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

Ceiling Concealed Duct


- High Static

Indoor unit

4-12

Ceiling Concealed Duct- High Static

BR Chassis

CONNECTOR NUMBER
CN-POWER
CN-MOTOR1
CN-MOTOR2
CN-D/PUMP
CN-COM
CN-EEV
CN-FLOAT
CN-PIPE/IN
CN-PIPE/OUT
CN-ROOM
CN-REMO
CN-ZON
CN-DISPLAY
CN-CC

LOCATION POINT
AC Power supply
Fan motor output
Fan motor output
Drain pump output
Communication
EEV Output
Float switch input
Suction pipe sensor
Discharge pipe sensor
Room sensor
Remote controller
Zontroller
RF Remote controller
Dry contact

Dip Switch Setting


SW3
GROUP

Off
Master

On
Slave

SW4

DRY CONTACT

Variable

Auto

SW5

EXTRA 1

Off

On

FUNCTION
AC Power line input for indoor controller
Motor output of BLDC
Motor output of BLDC
AC output for drain pump
Connection between indoor and outdoor
EEV Control output
Float switch sensing
Pipe in thermistor
Pipe out thermistor
Room air thermistor
Remote control line
Zone control line
RF Remote control line
Dry contact line
Remarks
Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

4-13

Indoor unit

Ceiling Concealed Duct


- High Static

B8 Chassis
Ceiling Concealed Duct- High Static

CONNECTOR NUMBER
CN-POWER
CN-MOTOR1, CN-MOTOR2
CN-D/PUMP
CN-COM
CN-EEV
CN-FLOAT
CN-PIPE/IN
CN-PIPE/OUT
CN-ROOM
CN-REMO
CN-CC
CN-DISPLAY
CN-OPTION
CN-ZONE

LOCATION POINT
AC Power supply
Fan motor output
Drain pump output
Communication
EEV Output
Float switch input
Suction pipe sensor
Discharge pipe sensor
Room sensor
Remote controller
Dry contact
RF Remocon
Option PCB
Zone controller

Dip Switch Setting


SW3
GROUP

Off
Master

On
Slave

SW4

DRY CONTACT

Variable

Auto

SW5

EXTRA 1

Off

On

FUNCTION
AC Power line input for indoor controller
Motor output of BLDC
AC Output for drain pump
Connection between indoor and outdoor
EEV Control output
Float switch sensing
Pipe in thermistor
Pipe out thermistor
Room thermistor
Remote control line
Dry contact line
RF Remocon receiver
Option PCB connector
Zone controller line
Remarks
Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

Ceiling Concealed Duct


- High Static

Indoor unit

4-14

6. Capacity Tables
6.1 Cooling Capacity
Ceiling Concealed Duct- High Static

Cooling capacity

20
14
TC SHC
kW kW

23
16
TC SHC
kW kW

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

30
22
TC SHC
kW
kW

Capacity
Index

Outdoor
air temp.
(DB, C)

2.2

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1

1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3

1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8

2.9
2.9
2.8
2.8
2.7
2.7
2.7
2.6
2.6
2.6
2.5
2.5
2.5
2.4
2.4
2.3

1.8
1.8
1.8
1.7
1.7
1.7
1.7
1.7
1.6
1.6
1.6
1.6
1.5
1.5
1.5
1.5

2.8

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8

2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1

2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8

2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0

2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3

3.7
3.6
3.6
3.5
3.5
3.4
3.4
3.4
3.3
3.3
3.2
3.2
3.1
3.1
3.0
3.0

2.3
2.3
2.2
2.2
2.2
2.1
2.1
2.1
2.1
2.0
2.0
2.0
2.0
1.9
1.9
1.9

3.6

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3

2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9

2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7

3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6

2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8

3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8

2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9

4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3

3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0

4.7
4.7
4.6
4.6
4.5
4.4
4.4
4.3
4.3
4.2
4.2
4.1
4.0
4.0
3.9
3.8

3.0
2.9
2.9
2.8
2.8
2.8
2.7
2.7
2.7
2.6
2.6
2.6
2.5
2.5
2.4
2.4

Notes:
TC: Total Capacity(kW)

4-15

32
24
TC SHC
kW kW

SHC: Sensible Heat Capacity(kW)

Indoor unit

Ceiling Concealed Duct


- High Static

Cooling capacity

23
16
TC SHC
kW kW

4.5

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0

2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8

3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6

3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1

4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5

3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5

4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8

3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6

5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4

3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7

5.9
5.8
5.8
5.7
5.6
5.5
5.5
5.4
5.3
5.3
5.2
5.1
5.0
5.0
4.9
4.8

3.7
3.6
3.6
3.6
3.5
3.5
3.4
3.4
3.3
3.3
3.2
3.2
3.1
3.1
3.1
3.0

5.6

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5

3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7

5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2

4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0

5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6

4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1

6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
5.8
5.7

4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.1
4.0

6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.6
6.4
6.4
6.3
6.2
6.0
5.9
5.8

4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.3
4.2
4.2
4.1
4.0
4.0
3.9
3.8

7.4
7.3
7.2
7.1
7.0
6.9
6.8
6.7
6.6
6.6
6.5
6.4
6.3
6.2
6.1
6.0

4.4
4.3
4.3
4.2
4.1
4.1
4.1
4.0
3.9
3.9
3.8
3.8
3.7
3.6
3.6
3.5

7.1

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8

4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3

5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7

4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7

6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6

5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1

7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1

5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2

7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.4
7.2

5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.2
5.1

8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.4
8.2
8.1
8.0
7.8
7.7
7.5
7.4

5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.5
5.4
5.3
5.2
5.1
5.0
4.9
4.8

9.3
9.2
9.1
9.0
8.8
8.7
8.7
8.5
8.4
8.3
8.2
8.1
7.9
7.8
7.7
7.6

5.5
5.5
5.4
5.3
5.2
5.2
5.1
5.1
5.0
4.9
4.8
4.8
4.7
4.6
4.6
4.5

Capacity
Index

Outdoor
air temp.
(DB, C)

Notes:
TC: Total Capacity(kW)

Ceiling Concealed Duct


- High Static

30
22
TC SHC
kW
kW

32
24
TC SHC
kW kW

SHC: Sensible Heat Capacity(kW)

Indoor unit

4-16

Ceiling Concealed Duct- High Static

20
14
TC SHC
kW kW

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

Ceiling Concealed Duct- High Static

Cooling capacity

20
14
TC SHC
kW kW

23
16
TC SHC
kW kW

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0

6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6

5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7

6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0

8.2
8.2
8.2
8.2
8.2
8.2
8.2
8.2
8.2
8.2
8.2
8.2
8.2
8.2
8.2
8.2

6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1

8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.5
8.4

6.2
6.2
6.2
6.2
6.2
6.2
6.2
6.2
6.2
6.2
6.2
6.2
6.2
6.2
6.1
6.0

9.8
9.8
9.8
9.8
9.8
9.8
9.8
9.8
9.7
9.4
9.3
9.2
9.0
8.9
8.7
8.5

6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.4
6.3
6.2
6.1
6.0
5.9
5.8
5.7

10.8
10.6
10.5
10.4
10.2
10.1
10.0
9.9
9.7
9.6
9.5
9.3
9.2
9.0
8.9
8.8

6.5
6.4
6.3
6.2
6.1
6.0
6.0
5.9
5.8
5.8
5.7
5.6
5.5
5.4
5.3
5.3

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
7.2
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3

6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5

8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9

7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3

9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5

7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0

10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3

7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
9.1
9.1
9.1
9.1
9.1
9.1
9.1
9.1
9.1
9.1
9.1
9.1
9.1
9.1
9.1
9.1

11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.0
10.8
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
12.8
12.5

8.1
8.1
8.1
8.1
8.1
8.1
8.1
8.1
8.1
8.1
8.1
8.1
8.1
8.1
7.9
7.7
9.4
9.4
9.4
9.4
9.4
9.4
9.4
9.4
9.4
9.4
9.4
9.4
9.4
9.4
9.2
9.0

12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.5
12.2
12.1
11.9
11.7
11.4
11.2
11.0
14.7
14.7
14.7
14.7
14.7
14.7
14.7
14.7
14.5
14.1
14.0
13.8
13.5
13.3
13.0
12.8

8.4
8.4
8.4
8.4
8.4
8.4
8.4
8.4
8.3
8.1
8.0
7.9
7.8
7.6
7.5
7.3
9.8
9.8
9.8
9.8
9.8
9.8
9.8
9.8
9.7
9.4
9.3
9.2
9.0
8.8
8.7
8.5

13.9
13.7
13.6
13.4
13.2
13.0
12.9
12.8
12.6
12.4
12.2
12.0
11.8
11.7
11.5
11.3
16.2
15.9
15.8
15.6
15.3
15.1
15.0
14.8
14.6
14.4
14.2
14.0
13.7
13.5
13.4
13.1

8.4
8.2
8.2
8.0
7.9
7.8
7.8
7.7
7.5
7.5
7.3
7.2
7.1
7.0
6.9
6.8
9.7
9.6
9.5
9.3
9.2
9.1
9.0
8.9
8.8
8.6
8.5
8.4
8.3
8.1
8.0
7.9

Capacity
Index

Outdoor
air temp.
(DB, C)

8.2

10.6

12.3

Notes:
TC: Total Capacity(kW)

4-17

30
22
TC SHC
kW
kW

32
24
TC SHC
kW kW

SHC: Sensible Heat Capacity(kW)

Indoor unit

Ceiling Concealed Duct


- High Static

Cooling capacity

14.1

22.4

28.0

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

20
14
TC SHC
kW kW

23
16
TC SHC
kW kW

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

30
22
TC SHC
kW
kW

32
24
TC SHC
kW kW

9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
15.1
15.1
15.1
15.1
15.1
15.1
15.1
15.1
15.1
15.1
15.1
15.1
15.1
15.1
15.1
15.1
18.9
18.9
18.9
18.9
18.9
18.9
18.9
18.9
18.9
18.9
18.9
18.9
18.9
18.9
18.9
18.9

11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5

13.2
13.2
13.2
13.2
13.2
13.2
13.2
13.2
13.2
13.2
13.2
13.2
13.2
13.2
13.2
13.2
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
26.2
26.2
26.2
26.2
26.2
26.2
26.2
26.2
26.2
26.2
26.2
26.2
26.2
26.2
26.2
26.2

16.9
16.9
16.9
16.9
16.9
16.9
16.9
16.9
16.6
16.2
16.1
15.8
15.5
15.2
14.9
14.7
26.8
26.8
26.8
26.8
26.8
26.8
26.8
26.8
26.8
26.8
26.8
26.8
26.8
26.8
26.8
26.8
33.5
33.5
33.5
33.5
33.5
33.5
33.5
33.5
33.5
33.5
33.5
33.5
33.5
33.5
33.5
33.5

18.5
18.3
18.1
17.8
17.6
17.3
17.2
17.0
16.7
16.5
16.3
16.0
15.8
15.5
15.3
15.1
29.4
29.0
28.7
28.3
27.9
27.5
27.4
27.0
26.6
26.2
25.8
25.4
25.0
24.6
24.3
23.9
36.8
36.3
35.9
35.4
34.9
34.4
34.2
33.7
33.2
32.8
32.3
31.8
31.3
30.8
30.4
29.9

Notes:
TC: Total Capacity(kW)

Ceiling Concealed Duct


- High Static

8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
16.1
16.1
16.1
16.1
16.1
16.1
16.1
16.1
16.1
16.1
16.1
16.1
16.1
16.1
16.1
16.1

9.6
9.6
9.6
9.6
9.6
9.6
9.6
9.6
9.6
9.6
9.6
9.6
9.6
9.6
9.6
9.6
14.3
14.3
14.3
14.3
14.3
14.3
14.3
14.3
14.3
14.3
14.3
14.3
14.3
14.3
14.3
14.3
17.8
17.8
17.8
17.8
17.8
17.8
17.8
17.8
17.8
17.8
17.8
17.8
17.8
17.8
17.8
17.8

10.4
10.4
10.4
10.4
10.4
10.4
10.4
10.4
10.4
10.4
10.4
10.4
10.4
10.4
10.4
10.4
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3

14.1
14.1
14.1
14.1
14.1
14.1
14.1
14.1
14.1
14.1
14.1
14.1
14.1
14.1
14.1
14.1
22.4
22.4
22.4
22.4
22.4
22.4
22.4
22.4
22.4
22.4
22.4
22.4
22.4
22.4
22.4
22.4
28.0
28.0
28.0
28.0
28.0
28.0
28.0
28.0
28.0
28.0
28.0
28.0
28.0
28.0
28.0
28.0

10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
15.7
15.7
15.7
15.7
15.7
15.7
15.7
15.7
15.7
15.7
15.7
15.7
15.7
15.7
15.7
15.7
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6
19.6

15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
14.7
14.4
23.8
23.8
23.8
23.8
23.8
23.8
23.8
23.8
23.8
23.8
23.8
23.8
23.8
23.8
23.8
23.8
29.8
29.8
29.8
29.8
29.8
29.8
29.8
29.8
29.8
29.8
29.8
29.8
29.8
29.8
29.8
29.8

10.9
10.9
10.9
10.9
10.9
10.9
10.9
10.9
10.9
10.9
10.9
10.9
10.9
10.9
10.6
10.4
16.1
16.1
16.1
16.1
16.1
16.1
16.1
16.1
16.1
16.1
16.1
16.1
16.1
16.1
16.1
16.1
20.2
20.2
20.2
20.2
20.2
20.2
20.2
20.2
20.2
20.2
20.2
20.2
20.2
20.2
20.2
20.2

11.4
11.4
11.4
11.4
11.4
11.4
11.4
11.4
11.2
10.9
10.8
10.7
10.5
10.3
10.1
9.9
16.9
16.9
16.9
16.9
16.9
16.9
16.9
16.9
16.9
16.9
16.9
16.9
16.9
16.9
16.9
16.9
21.1
21.1
21.1
21.1
21.1
21.1
21.1
21.1
21.1
21.1
21.1
21.1
21.1
21.1
21.1
21.1

11.3
11.1
11.0
10.8
10.7
10.5
10.5
10.3
10.2
10.0
9.9
9.7
9.6
9.4
9.3
9.2
16.7
16.5
16.3
16.1
15.9
15.6
15.5
15.3
15.1
14.9
14.7
14.4
14.2
14.0
13.8
13.6
20.9
20.6
20.4
20.1
19.8
19.5
19.4
19.1
18.9
18.6
18.3
18.1
17.8
17.5
17.3
17.0

SHC: Sensible Heat Capacity(kW)

Indoor unit

4-18

Ceiling Concealed Duct- High Static

Capacity
Index

Outdoor
air temp.
(DB, C)

Ceiling Concealed Duct- High Static

6.2 Heating Capacity


Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

Heating capacity

Indoor air temp. (DB, C)


16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

kW

kW

kW

kW

kW

kW

2.2

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.3
2.4
2.5
2.6
2.8
2.8
2.9
2.9
2.9
2.9
2.9

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.3
2.4
2.5
2.6
2.7
2.7
2.7
2.7
2.7
2.7
2.7

1.7
1.7
1.8
1.7
1.8
1.9
1.9
2.0
2.0
2.1
2.2
2.3
2.4
2.5
2.5
2.5
2.5
2.5
2.5

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.2
2.3
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.2
2.3
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

1.7
1.7
1.8
1.9
2.0
2.1
2.1
2.1
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

2.8

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

2.1
2.2
2.3
2.5
2.6
2.7
2.8
2.8
2.9
3.0
3.2
3.4
3.6
3.6
3.7
3.7
3.7
3.7
3.7

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.9
3.0
3.2
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

2.1
2.2
2.3
2.2
2.3
2.4
2.5
2.5
2.6
2.7
2.8
3.0
3.1
3.2
3.2
3.2
3.2
3.2
3.2

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.8
3.0
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.8
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0

2.1
2.2
2.3
2.4
2.6
2.7
2.7
2.7
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8

3.6

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

2.7
2.8
2.9
3.1
3.2
3.4
3.4
3.5
3.6
3.8
4.0
4.2
4.4
4.5
4.6
4.6
4.6
4.6
4.6

2.7
2.8
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.8
4.0
4.2
4.3
4.3
4.3
4.3
4.3
4.3
4.3

2.7
2.8
2.9
2.7
2.9
3.0
3.1
3.2
3.3
3.4
3.5
3.7
3.9
4.0
4.0
4.0
4.0
4.0
4.0

2.6
2.8
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.7
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9

2.6
2.7
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.7
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8

2.6
2.7
2.9
3.0
3.2
3.4
3.4
3.4
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5

Notes:
TC: Total Capacity(kW)

4-19

Indoor unit

Ceiling Concealed Duct


- High Static

Heating capacity

Indoor air temp. (DB, C)


16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

kW

kW

kW

kW

kW

kW

4.5

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

3.4
3.5
3.7
3.9
4.1
4.3
4.3
4.4
4.6
4.8
5.0
5.3
5.6
5.6
5.8
5.8
5.8
5.8
5.8

3.4
3.5
3.7
3.8
4.1
4.3
4.3
4.4
4.6
4.8
5.0
5.3
5.4
5.4
5.4
5.4
5.4
5.4
5.4

3.4
3.5
3.7
3.4
3.6
3.8
3.9
4.0
4.1
4.3
4.4
4.6
4.9
5.0
5.0
5.0
5.0
5.0
5.0

3.3
3.5
3.7
3.8
4.0
4.3
4.3
4.4
4.4
4.6
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8

3.3
3.4
3.7
3.8
4.0
4.2
4.3
4.4
4.4
4.6
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7

3.3
3.4
3.6
3.8
4.0
4.2
4.3
4.3
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4

5.6

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

4.2
4.3
4.6
4.9
5.1
5.4
5.4
5.5
5.7
6.0
6.2
6.6
7.0
7.1
7.2
7.2
7.2
7.2
7.2

4.2
4.3
4.6
4.8
5.1
5.4
5.4
5.5
5.7
6.0
6.2
6.6
6.7
6.7
6.7
6.7
6.7
6.7
6.7

4.2
4.3
4.6
4.3
4.5
4.8
4.9
5.0
5.1
5.4
5.5
5.8
6.2
6.3
6.3
6.3
6.3
6.3
6.3

4.2
4.3
4.6
4.8
5.0
5.4
5.4
5.5
5.6
5.8
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1

4.2
4.3
4.6
4.8
5.0
5.3
5.4
5.5
5.6
5.8
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9

4.2
4.3
4.5
4.8
5.0
5.3
5.4
5.4
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

7.1

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

5.4
5.5
5.8
6.2
6.5
6.8
6.9
7.0
7.3
7.6
7.9
8.4
8.9
9.0
9.2
9.2
9.2
9.2
9.2

5.4
5.5
5.8
6.1
6.5
6.8
6.9
7.0
7.3
7.6
7.9
8.4
8.6
8.6
8.6
8.6
8.6
8.6
8.6

5.4
5.5
5.8
5.5
5.8
6.0
6.2
6.3
6.5
6.8
7.0
7.4
7.8
8.0
8.0
8.0
8.0
8.0
8.0

5.3
5.5
5.8
6.1
6.4
6.8
6.9
7.0
7.1
7.4
7.7
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8

5.3
5.4
5.8
6.1
6.4
6.7
6.9
7.0
7.1
7.4
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5

5.3
5.4
5.8
6.1
6.4
6.7
6.8
6.8
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0

Notes:
TC: Total Capacity(kW)

Ceiling Concealed Duct


- High Static

Indoor unit

4-20

Ceiling Concealed Duct- High Static

Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

Ceiling Concealed Duct- High Static

Heating capacity

Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

Indoor air temp. (DB, C)


16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

kW

kW

kW

kW

kW

kW

8.2

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

6.2
6.3
6.7
7.1
7.5
7.8
7.9
8.1
8.4
8.7
9.1
9.7
10.2
10.4
10.6
10.6
10.6
10.6
10.6

6.2
6.3
6.7
7.0
7.5
7.8
7.9
8.1
8.4
8.7
9.1
9.7
9.8
9.8
9.8
9.8
9.8
9.8
9.8

6.2
6.3
6.7
6.3
6.6
7.0
7.1
7.3
7.5
7.8
8.1
8.5
9.0
9.2
9.2
9.2
9.2
9.2
9.2

6.1
6.3
6.7
7.0
7.4
7.8
7.9
8.1
8.2
8.5
8.9
8.9
8.9
8.9
8.9
8.9
8.9
8.9
8.9

6.1
6.3
6.7
7.0
7.4
7.7
7.9
8.1
8.2
8.5
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6

6.1
6.3
6.6
7.0
7.4
7.7
7.8
7.9
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0

10.6

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

8.0
8.2
8.7
9.2
9.6
10.1
10.2
10.5
10.8
11.3
11.8
12.5
13.2
13.4
13.7
13.7
13.7
13.7
13.7

8.0
8.2
8.7
9.0
9.6
10.1
10.2
10.5
10.8
11.3
11.8
12.5
12.7
12.7
12.7
12.7
12.7
12.7
12.7

8.0
8.2
8.7
8.2
8.6
9.0
9.2
9.4
9.7
10.1
10.4
11.0
11.6
11.9
11.9
11.9
11.9
11.9
11.9

7.9
8.2
8.7
9.0
9.5
10.1
10.2
10.5
10.6
11.0
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5

7.9
8.1
8.7
9.0
9.5
10.0
10.2
10.5
10.6
11.0
11.2
11.2
11.2
11.2
11.2
11.2
11.2
11.2
11.2

7.9
8.1
8.6
9.1
9.5
10.0
10.1
10.2
10.4
10.4
10.4
10.4
10.4
10.4
10.4
10.4
10.4
10.4
10.4

12.3

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

9.2
9.5
10.1
10.6
11.2
11.7
11.9
12.1
12.6
13.1
13.7
14.5
15.3
15.5
15.9
15.9
15.9
15.9
15.9

9.2
9.5
10.1
10.5
11.2
11.7
11.9
12.1
12.6
13.1
13.7
14.5
14.8
14.8
14.8
14.8
14.8
14.8
14.8

9.2
9.5
10.1
9.5
10.0
10.4
10.7
10.9
11.3
11.7
12.1
12.8
13.5
13.8
13.8
13.8
13.8
13.8
13.8

9.1
9.5
10.1
10.5
11.0
11.7
11.9
12.1
12.2
12.8
13.3
13.4
13.4
13.4
13.4
13.4
13.4
13.4
13.4

9.1
9.4
10.1
10.5
11.0
11.6
11.9
12.1
12.2
12.8
13.0
13.0
13.0
13.0
13.0
13.0
13.0
13.0
13.0

9.1
9.4
9.9
10.5
11.0
11.6
11.7
11.8
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1

Notes:
TC: Total Capacity(kW)

4-21

Indoor unit

Ceiling Concealed Duct


- High Static

Heating capacity

Indoor air temp. (DB, C)


16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

kW

kW

kW

kW

kW

kW

14.1

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

10.7
11.0
11.6
12.2
12.9
13.5
13.7
14.0
14.5
15.1
15.7
16.7
17.7
17.9
18.3
18.3
18.3
18.3
18.3

10.7
11.0
11.6
12.1
12.9
13.5
13.7
14.0
14.5
15.1
15.7
16.7
17.0
17.0
17.0
17.0
17.0
17.0
17.0

10.7
11.0
11.6
10.9
11.5
12.0
12.3
12.6
13.0
13.5
13.9
14.7
15.5
15.9
15.9
15.9
15.9
15.9
15.9

10.5
11.0
11.6
12.1
12.7
13.5
13.7
14.0
14.1
14.7
15.3
15.4
15.4
15.4
15.4
15.4
15.4
15.4
15.4

10.5
10.8
11.6
12.1
12.7
13.4
13.7
14.0
14.1
14.7
14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.9

10.5
10.8
11.4
12.1
12.7
13.4
13.5
13.6
13.9
13.9
13.9
13.9
13.9
13.9
13.9
13.9
13.9
13.9
13.9

22.4

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

16.9
17.4
18.4
19.4
20.4
21.4
21.7
22.2
22.9
23.9
25.0
26.5
28.0
28.4
29.0
29.0
29.0
29.0
29.0

16.9
17.4
18.4
19.2
20.4
21.4
21.7
22.2
22.9
23.9
25.0
26.5
27.0
27.0
27.0
27.0
27.0
27.0
27.0

16.9
17.4
18.4
17.3
18.2
19.1
19.5
19.9
20.6
21.5
22.1
23.4
24.6
25.2
25.2
25.2
25.2
25.2
25.2

16.6
17.4
18.4
19.2
20.2
21.4
21.7
22.2
22.4
23.3
24.3
24.4
24.4
24.4
24.4
24.4
24.4
24.4
24.4

16.6
17.1
18.4
19.2
20.2
21.2
21.7
22.2
22.4
23.3
23.7
23.7
23.7
23.7
23.7
23.7
23.7
23.7
23.7

16.6
17.1
18.1
19.2
20.2
21.2
21.4
21.6
22.0
22.0
22.0
22.0
22.0
22.0
22.0
22.0
22.0
22.0
22.0

28.0

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

21.1
21.7
23.0
24.3
25.5
26.8
27.1
27.7
28.7
29.9
31.2
33.1
35.0
35.4
36.2
36.2
36.2
36.2
36.2

21.1
21.7
23.0
23.9
25.5
26.8
27.1
27.7
28.7
29.9
31.2
33.1
33.7
33.7
33.7
33.7
33.7
33.7
33.7

21.1
21.7
23.0
21.6
22.7
23.8
24.4
24.9
25.7
26.8
27.6
29.2
30.8
31.5
31.5
31.5
31.5
31.5
31.5

20.8
21.7
23.0
23.9
25.2
26.8
27.1
27.7
28.0
29.1
30.3
30.5
30.5
30.5
30.5
30.5
30.5
30.5
30.5

20.8
21.4
23.0
23.9
25.2
26.5
27.1
27.7
28.0
29.1
29.6
29.6
29.6
29.6
29.6
29.6
29.6
29.6
29.6

20.8
21.4
22.7
24.0
25.2
26.5
26.8
27.0
27.6
27.6
27.6
27.6
27.6
27.6
27.6
27.6
27.6
27.6
27.6

Notes:
TC: Total Capacity(kW)

Ceiling Concealed Duct


- High Static

Indoor unit

4-22

Ceiling Concealed Duct- High Static

Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

Ceiling Concealed Duct- High Static

7. External Static Pressure (E.S.P) & Air Flow


ARNU07GBHA2, ARNU09GBHA2, ARNU12GBHA2
ARNU15GBHA2, ARNU18GBHA2, ARNU24GBHA2
Setting Value
70
80
90
100
110
120
130
140
145
150

(Unit: CMM)

Static Pressure(mmAq(Pa))
3(29)

4(39)

5(49)

6(59)

7(69)

8(78)

9(88)

10(98)

12(118)

4.1
7.6
10.7
13.4
15.9
18.6
19.8
22.3
23.2
24.3

8.1
11.2
13.2
16.2
18.8
21.1
22.2
23.1

6.3
9.6
12.6
15.2
18.0
20.3
21.4
22.3

4.9
7.5
10.3
12.8
15.3
17.7
19.1
21.1

4.0
7.7
11.1
14.2
17.1
18.4
19.8

5.5
9.1
12.4
15.5
16.9
18.3

6.7
10.4
13.7
15.3
16.8

5.3
8.8
12.6
13.8
15.2

5.7
9.7
11.8
13.0

ARNU28GBGA2, ARNU36GBGA2, ARNU42GBGA2


Setting Value
70
80
90
100
110
120
130
140
143
150
160

(Unit: CMM)

Static Pressure(mmAq(Pa))
5(49)

6(59)

7(69)

8(78)

9(88)

10(98)

12(118)

14(137)

16(157)

4.0
12.1
17.0
21.4
25.8
30.0
36.0
37.5
41.0
42.4

6.9
15.5
19.6
24.0
28.5
32.1
33.9
38.0
41.6

4.13
11.01
17.53
21.8
26.93
30.41
32.1
36.0
38.2

6.2
14.0
19.8
25.3
29.0
30.7
34.5
36.1

4.2
11.6
17.9
23.4
27.4
28.8
32.1
35

6.6
14.6
21.8
25.9
27.2
30.1
34.6

12.1
18.1
21.6
23.0
26.3
31.1

14.6
17.8
20.1
22.4
26.8

11.3
14.5
16.8
18.2
23.3

ARNU48GBRA2
Setting Value
91
96
101
106
111
116
121
126

(Unit: CMM)
Static Pressure(mmAq(Pa))

5(49)

6(59)

8(78)

46.5
49.9
52.1
51.4
53.6
62.3
67.0
68.2

43.7
46.1
50.2
51.2
53.7
61.0
64.8
67.5

38.2
43.0
47.9
50.4
52.9
60.3
64.1
66.2

10(98) 12(118) 14(137) 15(147) 16(157) 17(168) 18(176) 20(196)


31.3
33.5
39.5
44.4
49.9
55.7
58.2
65.1

23.2
31.1
37.4
43.1
48.3
50.8
52.2
64.3

14.0
18.4
27.3
33.3
40.6
44.8
50.8
57.4

9.0
13.7
25.2
32.1
40.2
42.6
50.3
54.4

3.7
9.0
17.8
28.9
32.8
40.1
45.7
51.2

2.6
8.9
21.0
31.5
37.6
44.6
50.4

6.1
17.9
27.2
32.5
38.8
46.0

8.3
17.5
27.6
32.2
43.5

Note: 1. The above table shows the correlation between the air rates and E.S.P.

4-23

Indoor unit

Ceiling Concealed Duct


- High Static

URNU76GB8A2, URNU96GB8A2
Static Pressure(mmAq(Pa))
6(59)

9(88)

12(118)

15(147)

18(177)

20(196)

22(216)

23(226)

25(245)

60

40.5

65

52.7

70

63.7

47.1

75

71.1

56.9

44.7

80

76.3

69.7

55.2

85

83.3

78.6

67.4

55.9

91

89.7

87.1

78.9

67.6

54.2

95

93.4

91.4

86.1

77.0

66.4

50.6

30.0

100

93.4

91.4

88.3

84.9

75.9

69.5

60.8

43.1

105

93.2

91.3

88.3

84.9

81.1

77.4

69.2

67.9

51.3

Note: 1. The above table shows the correlation between the air rates and E.S.P.

Ceiling Concealed Duct


- High Static

Indoor unit

4-24

Ceiling Concealed Duct- High Static

Setting Value

(Unit: CMM)

Ceiling Concealed Duct- High Static

ARNU07GBHA2, ARNU09GBHA2, ARNU12GBHA2


ARNU15GBHA2, ARNU18GBHA2, ARNU24GBHA2
Capacity

High
(factory set)
7k
Standard
High
(factory set)
9k
Standard
High
(factory set)
12k
Standard
High
(factory set)
15k
Standard
High
(factory set)
18k
Standard

24k

Standard
Set value ESP(mmAq(Pa))

Mode

High
(factory set)
Standard

Hl
Mid
Low
Hl
Mid
Low
Hl
Mid
Low
Hl
Mid
Low
Hl
Mid
Low
Hl
Mid
Low
Hl
Mid
Low
Hl
Mid
Low
HI
Mid
Low
HI
Mid
Low
HI
Mid
Low
HI
Mid
Low

120
117
115
110
107
105
125
120
117
110
107
105
130
125
120
115
110
105
135
130
120
123
120
115
140
135
130
130
125
110
150
145
140
145
135
128

8(78)
6(59)
8(78)
6(59)
8(78)
6(59)
8(78)
6(59)
8(78)
6(59)
8(78)
6(59)

CMM

Lower Limit of External


Static Pressure(mmAq(Pa))

8.5
7.5
6
8.5
8
7.5
10
8.5
7.5
8.5
8
7.5
12
10
8.5
11
8.5
7.5
13.5
12
8.5
13.5
12
11
15.5
13.5
12.4
15.3
13.6
10.3
18.3
16.9
15.5
19
16.4
14.5

Upper Limit of External


Static Pressure(mmAq(Pa))

6(59)

12(118)

4(39)

8(78)

6(59)

12(118)

4(39)

8(78)

6(59)

12(118)

4(39)

8(78)

6(59)

12(118)

4(39)

8(78)

6(59)

12(118)

4(39)

8(78)

6(59)

12(118)

4(39)

8(78)

ARNU28GBGA2, ARNU36GBGA2, ARNU42GBGA2


Capacity

28k

High
(factory set)
Standard

36k

High
(factory set)
Standard
High
(factory set)

42k
Standard

4-25

Standard
Set value ESP(mmAq(Pa))

Mode
HI
Mid
Low
HI
Mid
Low
HI
Mid
Low
HI
Mid
Low
HI
Mid
Low
HI
Mid
Low

140
136
130
130
124
116
151
145
139
138
130
124
157
154
151
145
138
134

10(98)
8(78)
10(98)
8(78)
10(98)
8(78)

CMM

Lower Limit of External


Static Pressure(mmAq(Pa))

25.9
24.1
21.8
25.3
21.8
17.6
32.3
29
25.3
28.4
25.3
21.8
34.5
32.3
30.7
32
28.4
27.2

Indoor unit

Upper Limit of External


Static Pressure(mmAq(Pa))

8(78)

16(157)

6(59)

10(98)

8(78)

14(137)

6(59)

10(98)

8(78)

12(118)

6(59)

10(98)

Ceiling Concealed Duct


- High Static

ARNU48GBRA2
Standard
Set value ESP(mmAq(Pa))

Mode
High
(factory set)

48k
Standard

HI
Mid
Low
HI
Mid
Low

116
111
106
106
101
96

14(137)
10(98)

CMM

Lower Limit of External


Static Pressure(mmAq(Pa))

44.8
40.6
33.3
44.4
39.5
33.5

Upper Limit of External


Static Pressure(mmAq(Pa))

10(98)

20(196)

7(67)

14(137)

URNU76GB8A2, URNU96GB8A2
Capacity

76k

High
(factory set)
Standard

96k

Standard
Set value ESP(mmAq(Pa))

Mode

High
(factory set)
Standard

HI
Mid
Low
HI
Mid
Low
HI
Mid
Low
HI
Mid
Low

Ceiling Concealed Duct


- High Static

102
98
98
86
83
83
105
102
102
94
89
89

22(216)
15(147)
22(216)
15(147)

CMM

Lower Limit of External


Static Pressure(mmAq(Pa))

64
50
50
60
50
50
72
64
64
76
64
64

Indoor unit

Upper Limit of External


Static Pressure(mmAq(Pa))

12(118)

25(245)

12(118)

25(245)

12(118)

25(245)

12(118)

25(245)

4-26

Ceiling Concealed Duct- High Static

Capacity

8. Electric Characteristics
Ceiling Concealed Duct- High Static

Units

Power Supply

Input(W)

MFA

kW

FLA

2.32

15

0.118

1.06

150

150

BH

2.32

15

0.118

1.06

150

150

ARNU12GBHA2

BH

2.32

15

0.118

1.06

150

150

ARNU15GBHA2

BH

2.32

15

0.118

1.06

150

150

ARNU18GBHA2

BH

2.32

15

0.118

1.06

150

150

ARNU24GBHA2

BH

Max:264

2.32

15

0.118

1.06

150

150

ARNU28GBGA2

BG

Min:198

4.31

15

0.39

2.65

450

450

ARNU36GBGA2

BG

4.31

15

0.39

2.65

450

450

ARNU42GBGA2

BG

4.31

15

0.39

2.65

450

450

ARNU48GBRA2

BR

4.45

15

0.39

2.76

450

450

URNU76GB8A2

B8

7.47

15

0.75

5.18

800

800

URNU96GB8A2

B8

7.47

15

0.75

5.18

800

800

ARNU07GBHA2

BH

2.32

15

0.118

1.06

150

150

ARNU09GBHA2

BH

2.32

15

0.118

1.06

150

150

ARNU12GBHA2

BH

2.32

15

0.118

1.06

150

150

ARNU15GBHA2

BH

2.32

15

0.118

1.06

150

150

ARNU18GBHA2

BH

2.32

15

0.118

1.06

150

150

ARNU24GBHA2

BH

Max:242

2.32

15

0.118

1.06

150

150

ARNU28GBGA2

BG

Min:198

4.31

15

0.39

2.65

450

450

ARNU36GBGA2

BG

4.31

15

0.39

2.65

450

450

ARNU42GBGA2

BG

4.31

15

0.39

2.65

450

450

ARNU48GBRA2

BR

4.45

15

0.39

2.76

450

450

URNU76GB8A2

B8

7.47

15

0.75

5.18

800

800

URNU96GB8A2

B8

7.47

15

0.75

5.18

800

800

Model

Type

ARNU07GBHA2

BH

ARNU09GBHA2

Symbols:
MCA : Min, Circuit Amps(A)
MFA : Max. Fuse Amps(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amps(A)
IFM : Indoor Fan Motor

Hz

50

60

Volts

220~ 240

220

Voltage Range MCA

IFM

Cooling Heating

Note :
1. Voltage range
Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above the listed range limits,
2. Maximum allowable voltage unbalance between phases is 2%
3. MCA/MFA
MCA=1.25 x FLA + 1
MFA 4 x FLA
(Next lower standard fuse rating. Min. 15A)
4. Select wire size based on the MCA
5. Instead of fuse, use Circuit Breaker.

4-27

Indoor unit

Ceiling Concealed Duct


- High Static

9. Sound Levels
Overall
SUCTION

DUCT

DUCT
1.5m

2m

Model

1m
1m

Sound Level dB(A)

Ceiling Concealed Duct- High Static

DISCHARGE

Notes:
- Sound measured at 1.5m away from the center of the unit.
- Data is valid at free field condition
- Data is valid at nominal operating condition
- Reference accoustic pressure OdB = 20Pa
- Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment is installed.

Sound Level dB(A)

Model

ARNU07GBHA2

H
34

M
33

L
32

ARNU28GBGA2

H
44

M
42

L
40

ARNU09GBHA2

35

34

33

ARNU36GBGA2

46

44

42

ARNU12GBHA2

37

35

34

ARNU42GBGA2

48

46

45

ARNU15GBHA2

39

38

37

ARNU48GBRA2

45

43

41

ARNU18GBHA2

42.5

41

37

URNU76GB8A2

50

48

48

ARNU24GBHA2

45

43

41

URNU96GB8A2

52

50

50

Sound Pressure Level


ARNU09GBHA2

ARNU12GBHA2
80

70

70

70

NC-65

60

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
20

10

NC-25
Approximate
Hearing
Threshold
63

Ceiling Concealed Duct


- High Static

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
20

NC-20

NC-15
125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)

NC-65

60

10

NC-25
Approximate
Hearing
Threshold
63

Octave Band Sound Pressure Level (dB re 20Pa )

80

Octave Band Sound Pressure Level (dB re 20Pa )

Octave Band Sound Pressure Level (dB re 20Pa )

ARNU07GBHA2
80

NC-60

Indoor unit

NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
20

NC-20

NC-15
125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)

NC-65

60

10

NC-25
Approximate
Hearing
Threshold
63

NC-20

NC-15
125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)

4-28

ARNU18GBHA2
70

NC-65
NC-60
NC-55
NC-50
NC-45

40

NC-40
NC-35

30

NC-30

20

10

NC-25
Approximate
Hearing
Threshold
63

NC-60

250

500

NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
NC-25

20

NC-20

125

NC-65

60

NC-15
1000 2000 4000 8000

10

Approximate
Hearing
Threshold
63

250

500

NC-15
1000 2000 4000 8000

NC-60

NC-50

NC-40

NC-30
20

10

NC-55
NC-50
NC-45
NC-40
NC-35
NC-30

20

10

NC-25
Approximate
Hearing
Threshold
63

NC-60

NC-50

250

500

NC-15
1000 2000 4000 8000

NC-45

40

NC-40
NC-35

30

NC-30

10

Approximate
Hearing
Threshold
63

ARNU48GBRA2

80

70

70

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
20

10

NC-25
Approximate
Hearing
Threshold
63

125

250

500

NC-15
1000 2000 4000 8000

NC-15
1000 2000 4000 8000

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30

10

NC-25
Approximate
Hearing
Threshold
63

125

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
NC-25

20

10

Approximate
Hearing
Threshold
63

125

250

500

Octave Band Center Frequency (Hz)

Indoor unit

500

NC-15
1000 2000 4000 8000

70

NC-65

60

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
NC-25

20

NC-20
NC-15
1000 2000 4000 8000

250

URNU96GB8A2

80

NC-65

NC-20

Octave Band Center Frequency (Hz)

URNU76GB8A2

60

NC-20

Octave Band Center Frequency (Hz)

4-29

Octave Band Sound Pressure Level (dB re 20Pa )

80

NC-65

500

NC-15
1000 2000 4000 8000

NC-65

Octave Band Center Frequency (Hz)

Octave Band Center Frequency (Hz)

60

250

500

60

NC-20

125

250

20

NC-25

20

NC-20

125

NC-55

50

Octave Band Sound Pressure Level (dB re 20Pa )

NC-60

NC-65

Octave Band Sound Pressure Level (dB re 20Pa )

70

Octave Band Sound Pressure Level (dB re 20Pa )

70

60

125

ARNU42GBGA2

ARNU36GBGA2

NC-65

NC-20

Octave Band Center Frequency (Hz)

70

30

NC-25
Approximate
Hearing
Threshold
63

80

40

NC-35

30

80

50

NC-45

40

80

60

NC-55

50

Octave Band Center Frequency (Hz)

ARNU28GBGA2

NC-65

60

NC-20

125

Octave Band Center Frequency (Hz)

Octave Band Sound Pressure Level (dB re 20Pa )

70

Octave Band Sound Pressure Level (dB re 20Pa )

70

Octave Band Sound Pressure Level (dB re 20Pa )

80

50

Octave Band Sound Pressure Level (dB re 20Pa )

ARNU24GBHA2

80

60

Octave Band Sound Pressure Level (dB re 20Pa )

Ceiling Concealed Duct- High Static

ARNU15GBHA2
80

10

Approximate
Hearing
Threshold
63

NC-20

125

250

500

NC-15
1000 2000 4000 8000

Octave Band Center Frequency (Hz)

Ceiling Concealed Duct


- High Static

10. Installation

Air outlet vents

Ceiling Concealed Duct- High Static

Please read this instruction sheet completely before installing the product.
When the power cord is damaged, replacement work shall be performed by authorized personnel only.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Air filters

Air intake vents


TEMP

Wired LCD Remote Control

Remote Controller

Required Parts

Required Tools

Connecting cable
Pipes: Gas side
Liquid side
Hanging Bolt
(W 3/8 or M10 length 650mm)
Insulated drain hose
Additional Drain hose

Level
Screw driver
Electric drill
Hole core drill
Flaring Tool set
Torque Wrenches
Hexagonal Wrench
Gas-leak detector
Thermometer

10.1 Selection of the best location


Install the air conditioner in the location that satisfies the
following conditions.
The place shall easily bear a load exceeding four times
the indoor units weight.
The place shall be able to inspect the unit as the figure.
The place where the unit shall be leveled.
The place shall allow easy water drainage.(Suitable
dimension H is necessary to get a slope to drain as figure.)
The place shall easily connect with the outdoor unit.
The place where the unit is not affected by an electrical
noise.
The place where air circulation in the room will be good .
There should not be any heat source or steam near the
unit.
The servicing inspection hole in the ceiling should be as
large as the product
The selection of the servicing hole should be approved
by the customer

Ceiling Concealed Duct


- High Static

[Inspection Hole Standard]


Number of
Inspection hole

Distance between
False ceiling & Actual ceiling

More than 100cm

20cm to 100cm

Hole size should be


more than the size of IDU.

Less than 20cm

Indoor unit

Remarks
Sufficient space in the
ceiling for servicing.
Insufficient space.
Difficult for servicing
Minimum height for
motor replacement.

4-30

BH/BG/BR Chassis

A
B

Installation of Unit
Install the unit above the ceiling correctly.

C
E

CASE 1

POSITION OF SUSPENSION BOLT

(G)

Apply a joint-canvas between the unit and duct to absorb


unnecessary vibration.
Apply a filter Accessory at air return hole.
Refer to the Dimensions.
(Unit:mm)

Ceiling Concealed Duct- High Static

10.2 Ceiling dimension and hanging bolt location

Dimension

(G)

932

882

355

47

450

30

87

750

158

BG

1232

1182

355

47

450

30

87

830

186

BR

1282 1230

477

56

590

30

Chassis

BH

Drainage hole

B8 Chassis

120 1006 294

(Unit:mm)
Dimension

Chassis

B8

1680 1565 1160 330 460 580 700 1400 1635 390 445 15

Install the unit leaning to a drainage hole side as a figure


for easy water drainage.

CASE 2
POSITION OF CONSOLE BOLT
A place where the unit will be leveled and that can support the weight of the unit.
A place where the unit can withstand its vibration.
A place where service can be easily performed.

4-31

Indoor unit

M10 Nut

X4

M10 washer

X4

M10 washer

X4

M10 Nut

X8

Ceiling Concealed Duct


- High Static

NOTE:

Select and mark the position for fixing bolts.


Drill the hole for set anchor on the face of ceiling.

Insert the set anchor and washer onto the suspension bolts for locking the suspension bolts on the
ceiling.
Mount the suspension bolts to the set anchor firmly.
Secure the installation plates onto the suspension
bolts (adjust level roughly) using nuts, washers and
spring washers.

Old building

New building

1 Set anchor
2 Plate washer
3 Spring washer
4 Nut

CAUTION

5 Suspension
bolts

Tighten the nut and bolt to prevent unit falling.

10.3 Connecting Cables between Indoor Unit and Outdoor Unit


Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively
Terminal Block Indoor
1(L)

2(N)

SODU

INTERNET DRY1 DRY2 GND 12V

IDU
-

Outdoor
Unit

INDOOR POWER INPUT

WARNING
Make sure that the screws of the terminal are not loose.

Clamping of cables
1) Arrange 2 power cables on the control panel.
2) First, fasten the steel clamp with a screw to the inner boss of control panel.
3) For the cooling model, fix the other side of the clamp with a screw strongly. For the heat pump model, put the
0.75mm2 cable(thinner cable) on the clamp and tighten it with a plastic clamp to the other boss of the control panel.

Ceiling Concealed Duct


- High Static

Indoor unit

4-32

Ceiling Concealed Duct- High Static

Throughly study the following installation locations:


1. In such places as restaurants and kitchens, considerable amount of oil steam and flour adhere to the fan, the fin of the heat
exchanger, resulting in heat exchange reduction, spraying, dispersing of water drops, etc.
In these cases, take the following actions:
Make sure that the ventilation fan for smoke-collecting hood on a cooking table has sufficient capacity so that it draws oily
steam which should not flow into the suction of the air conditioner.
Make enough distance from a cooking room to install the air conditioner in such a place where it may not suck in oil steam.
2. Avoid installing air conditioner in such circumstances where cutting oil mist or iron powder is in suspension in factories, etc.
3. Avoid places where inflammable gas is generated, flows in, is stored or vented.
4. Avoid places where sulfurous acid gas or corrosive gas is generated.
5. Avoid places near high frequency generators.

Ceiling Concealed Duct- High Static

THERMAL INSULATION

All thermal insulation must comply with local requirement.

INDOOR UNIT
BH/BG/BR Chassis

Union for liquid pipe

Thermal insulator for refrigerant pipe


(Local supply) Thermal insulator for
piping(Local supply)

Refrigerant pipe and thermal


insulator(Local supply)
Hose clamp for thermal insulator
(Local supply)

B8

Thermal insulator for refrigerant pipe


(Local supply)
Union for gas pipe

Overlap with thermal


insulator for piping.
Hose clamp for thermal insulator(Local supply)
Make sure that there is no clearance here.

Union for gas pipe


Thermal insulator for refrigerant pipe
(Local supply)
Hose crip for thermal insulator
(Local supply)
Refrigerant pipe and therma
insulator(Local supply)

Union for liquid pipe

10.4 Checking the Drainage


1) Checking the Drainage

BH/BG/BR Chassis

1. Remove the Air Filter.

B8

2. Check the drainage.


Spray one or two glasses of water on the evaporator.
Ensure that water flows through drain hose of
indoor unit without any leakage.

4-33

Indoor unit

Ceiling Concealed Duct


- High Static

10.5 Indoor Unit Drain Piping


Drain piping must have down-slope (1/50 to 1/100): be sure not to provide up-and-down slope to prevent reversal flow.
During drain piping connection, be careful not to exert extra force on the
drain port on the indoor unit.
The outside diameter of the drain connection on the indoor unit is 32mm.

Indoor unit

Maintenance
drain port

Piping material: Polyvinyl chloride pipe inner


diometes 25mm and pipe fittings
Be sure to install heat insulation on the drain piping.

1/50~1/100

Heat insulation material: Polyethylene foam with


thickness more than 8 mm.

MAX 700mm

Drain test
The air conditioner uses a drain pump to drain water.
Use the following procedure to test the drain pump operation:
Feed water

Drain Pump

Flexible drain hose


(accessory)

Connect the main drain pipe to the exterior and leave it provisionally until the test comes to an end.
Main
drain pipe
Feed water to the flexible drain hose and check the piping
for leakage.
Drain

Be sure to check the drain pump for normal operation and


port
Glue the joint
noise when electrical wiring is complete.
Drain hose connection
Use the clip (accessory) When the test is complete, connect the flexible drain hose to
the drain port on the indoor unit.

Drain pan

CAUTION

Hanger
distance
1~15m

Hanger Bracket
1/50~1/100 slope

Metal
clamp

The supplied flexible drain hose should not be strained.


A strained hose may cause leakage of water.

Flexible drain hose

Max 700mm

Max 300mm

Insulation

Flexible drain hose


Flexible drain hose
Flexible drain hose

Ceiling Concealed Duct


- High Static

Indoor unit

4-34

Ceiling Concealed Duct- High Static

Upward
routing
not allowed

Pipe clamp

Ceiling Concealed Duct- High Static

10.6 Ground drain piping


a) It is standard work practice to make connections to the main pipe from above. The pipe down from the
combination should be as large as possible.

Face the vent pipe opening facing downward to


keep foreign matter from penetrating the system
Face piping
downward
Vent pipe

b) The pipe work should be kept as short as possible and the number of indoor units per group kept to a
minimum.

10.7 Use of an auxiliary drain hose(flexible)


a) To connect drain pipe to the drain socket on the indoor unit, an auxiliary flexible drain hose should be
used. auxiliary flexible drain hose allows that the drain pipe can be connected to the socket without breaking by excessive strain.
Auxiliary drain hose

Thermal insulation (drain pipe area)

Metal clamp

Metal clamp
Thermal insulation(bend area)
Drain pan

Important points
- The drain pipe should be at least equal in size to that of the indoor unit.
- The drain pipe is thermally insulated to prevent the formation of condensation inside the pipe.
- The drain up mechanism should be fitted before the indoor unit is installed and when the electricity has
been connected some water should be added to the drain pan and the drain pump to check and see if it is
functioning correctly.
- All connections should be secure. (Special care is needed with PVC pipe)
- Insulate auxiliary drain hose with thermal insulation band.

4-35

Indoor unit

Ceiling Concealed Duct


- High Static

WIRED REMOTE CONTROLLER INSTALLATION

Do not install the remote controller where it can be affected by:


- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)

TEMP

yes

Remote Controller

no

TEMP

Controller
Remote

TEMP

Remote Controller

5feet
(1.5meters)

no

no

Fig.1 Typical locations for remote controller

Ceiling Concealed Duct


- High Static

Indoor unit

4-36

Ceiling Concealed Duct- High Static

Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.

11. Accessories
Ceiling Concealed Duct- High Static

Standard Accessories
Name

Drain hose

Clamp metal

Quantity

1 EA

1 EA

Washer for
hanging backet
8 EA

Clamp
(Tie Wrap)

Insulation for
fitting

4 EA

1 SET

(Other)

Owner's manual
Installation manual
Shape

for gas pipe

for liquid pipe

CAUTION
Use only those accessories (Standard or optional) which have designated specifications.

4-37

Indoor unit

Ceiling Concealed Duct


- High Static

1. List of functions
2. Specifications
3. Dimensions & Gravity point
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. External Static Pressure (E.S.P) & Air Flow
8. Electric Characteristics
9. Sound Levels
10. Installation
11. Accessories

Ceiling Concealed Duct


- Low Static

Indoor unit

Ceiling Concealed Duct- Low Static

Ceiling Concealed Duct


(Low Static)

Ceiling Concealed Duct- Low Static

1. List of functions
Category

Air flow

Air purifying

Installation

Reliability

Convenience

Individual
control

Special
function kit

Function
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Wide wired remote controller
Deluxe wired remote controller
Simple wired remote controller
Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
Zone control
CTIE
Electro thermostat

ARNU07GB1G2, ARNU09GB1G2, ARNU12GB1G2,


ARNU15GB1G2, ARNU18GB2G2, ARNU24GB2G2
1
3/3/3
X
X
O
O
O
X
O
O
O
O(Heat recovery)
X
O(Heat pump or Cooling only)
O
O
O
O
O
O
O
Accessory
Accessory
Accessory
Accessory
X
Accessory
Accessory
-

O : Applied
X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

5-1

Indoor unit

Ceiling Concealed Duct


- Low Static

2. Specifications

Cooling Capacity

Heating Capacity

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h

Casing
Dimensions(WxDxH) Body

mm
inch

Rows x Columns x FPI


Face Area
m2
Type
Motor Output x Number
W
Running Current
A
Air Flow Rate(H/M/L)
CMM
(High Mode-factory set)
cfm
Fan
External Static Pressure mmAq(Pa)
Air Flow Rate(H/M/L)
CMM
(Standard Mode)
cfm
External Static Pressure mmAq(Pa)
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side
mm(inch)
Pipe Connections Gas Side
mm(inch)
Drain Pipe(Internal Dia.)
mm
Net Weight
kg(lbs)
Noise Level(Sound Press, 1.5m, H/M/L) dB(A)3
Coil

Power Supply
Refrigerant Control
Power cable
Transmission cable

, V, Hz
mm2
mm2

Ceiling Concealed Duct (Low Static)


ARNU07GB1G2
ARNU09GB1G2
ARNU12GB1G2
2.2
2.8
3.6
1,900
2,400
3,100
7,500
9,600
12,300
2.5
3.2
4.0
2,200
2,800
3,400
8,500
10,900
13,600
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
820 x 575 x 190
820 x 575 x 190
820 x 575 x 190
32.3 x 21.7 x 7.5
32.3 x 21.7 x 7.5
32.3 x 21.7 x 7.5
2x11x21
2x11x21
2x11x21
0.16
0.16
0.16
Sirocco Fan
Sirocco Fan
Sirocco Fan
28
28
28
0.15
0.15
0.15
8.5/7.5/6.5
9.5/8.5/7.5
10.5/9.5/8.5
300/265/229
335/300/265
371/335/300
2(20)
2(20)
2(20)
8.5/7.5/6.5
9.5/8.5/7.5
10.5/9.5/8.5
300/265/229
335/300/265
371/335/300
0(0)
0(0)
0(0)
Direct
Direct
Direct
BLDC
BLDC
BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene
Foamed polystrene
Foamed polystrene
Fuse
Fuse
Fuser
6.35(1/4)
6.35(1/4)
6.35(1/4)
12.7(1/2)
12.7(1/2)
12.7(1/2)
25.4
25.4
25.4
21(46.3)
21(46.3)
21(46.3)
35/33/31
36/35/33
37/36/35
1, 220 ~ 240, 50
1, 220 ~ 240, 50
1, 220 ~ 240, 50
1, 220, 60
1, 220, 60
1, 220, 60
EEV
EEV
EEV
CV1.5 x 3C
CV1.5 x 3C
CV1.5 x 3C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Noise Level is Standard Mode
(for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dB(A))

Ceiling Concealed Duct


- Low Static

Indoor unit

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

5-2

Ceiling Concealed Duct- Low Static

Type
Model

Ceiling Concealed Duct (Low Static)


ARNU15GB1G2
ARNU18GB2G2
ARNU24GB2G2
4.5
5.6
7.1
3,900
4,800
6,100
Cooling Capacity
15,400
19,100
24,200
5.0
6.3
8.0
4,300
5,400
6,900
Heating Capacity
17,100
21,500
27,300
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
Casing
820 x 575 x 190
1,100 x 575 x 190
1,100 x 575 x 190
mm
Dimensions(WxDxH) Body
32.3 x 21.7 x 7.5
43.3 x 21.7 x 7.5
43.3 x 21.7 x 7.5
inch
2x11x21
3x10x18
3x10x18
Rows
x
Columns
x
FPI
Coil
0.16
0.23
0.23
Face Area
m2
Sirocco Fan
Sirocco Fan
Sirocco Fan
Type
28
76
76
Motor Output x Number
W
0.15
0.38
0.38
Running Current
A
11.5/10.5/9.5
16/14/12
19/17/15
Air Flow Rate(H/M/L)
CMM
406/371/335
565/494/424
671/600/530
(High Mode-factory set)
cfm
2(20)
2(20)
2(20)
Fan
External Static Pressure mmAq(Pa)
11.5/10.5/9.5
16/14/12
19/17/15
Air Flow Rate(H/M/L)
CMM
406/371/335
565/494/424
671/600/530
(Standard Mode)
cfm
0(0)
0(0)
0(0)
External Static Pressure mmAq(Pa)
Direct
Direct
Direct
Drive
BLDC
BLDC
BLDC
Motor type
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Temperature Control
Foamed polystrene
Foamed polystrene
Foamed polystrene
Sound Absorbing Thermal Insulation Material
Air Filter
Fuser
Fuse
Fuse
Safety Device
6.35(1/4)
6.35(1/4)
9.52(3/8)
Liquid Side
mm(inch)
12.7(1/2)
12.7(1/2)
15.88(5/8)
Pipe Connections Gas Side
mm(inch)
25.4
25.4
25.4
Drain Pipe(Internal Dia.)
mm
21(46.3)
26(57.3)
26(57.3)
Net Weight
kg(lbs)
38/37/36
40/37/34
43/40/37
Noise Level(Sound Press, 1.5m, H/M/L) dB(A)3
1, 220 ~ 240, 50
1, 220 ~ 240, 50
1, 220 ~ 240, 50
Power Supply
, V, Hz
1, 220, 60
1, 220, 60
1, 220, 60
EEV
EEV
EEV
Refrigerant Control
CV1.5 x 3C
CV1.5 x 3C
CV1.5 x 3C
Power cable
mm2
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
Transmission cable
mm2

Ceiling Concealed Duct- Low Static

Type
Model

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Noise Level is Standard Mode
(for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dB(A))

5-3

Indoor unit

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

Ceiling Concealed Duct


- Low Static

575

18

154

Indoor unit

383

18

B1 : 448
B2 : 573

B
A

5
13

161
14
B1 : 186
B2 : 175
B1 : 73
B2 : 81

65
60

190

Gas pipe connection


Drain pipe connection
Power supply connection
Air discharge
Air suction

2
3
4
5
6

1072

794

Descripition

(unit : mm)

1131

856

Unit size(7k,9k,12k,18k):6.35
Unit size(24k):9.52
Unit size(7k,9k,12k,18k):12.7
Unit size(24k):15.88

1008

728

(unit: mm)

Gravity point

CHASSIS CODE: B1/B2

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Note

Liquid pipe connection

Name

1100

820

Number

ARNU18GB2G2
ARNU24GB2G2

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

ARNU07GB1G2
ARNU09GB1G2
ARNU12GB1G2
ARNU15GB1G2

ARNU07GB1G2
ARNU09GB1G2
ARNU12GB1G2
ARNU15GB1G2
ARNU18GB2G2
ARNU24GB2G2

Ceiling Concealed Duct- Low Static

Ceiling Concealed Duct


- Low Static
216
24

Ceiling Concealed Duct (Low Static)

3. Dimensions & Gravity point

5-4

277

190

Ceiling Concealed Duct- Low Static

4. Piping Diagrams

Heat Exchanger

EEV
Filter

Th3

:Cooling
:Heating

Th2
Sirocco Fan

Th1

Filter

lndoor unit

Refrigerant pipe connection port diameter


[Unit: mm(inch)]

5-5

MODEL

GAS

LIQUID

ARNU07GB1G2

12.7(1/2)

6.35(1/4)

ARNU09GB1G2

12.7(1/2)

6.35(1/4)

ARNU12GB1G2

12.7(1/2)

6.35(1/4)

ARNU15GB1G2

12.7(1/2)

6.35(1/4)

ARNU18GB2G2

12.7(1/2)

6.35(1/4)

ARNU24GB2G2

15.88(5/8)

9.52(3/8)

LOC.

Description

Th1

Room thermistor

Th2

Pipe in thermistor

Th3

Pipe out thermistor

Indoor unit

Ceiling Concealed Duct


- Low Static

5. Wiring Diagrams
B1/B2 Chassis
Ceiling Concealed Duct- Low Static

CONNECTOR NUMBER
CN-MOTOR1
CN-MOTOR2
CN-PIPE/OUT
CN-PIPE/IN
CN-ROOM
CN-REMO
CN-FLOAT
CN-EEV
CN-D/PUMP
CN-OPTION
CN-COM
CN-D/PUMP
CN-POWER
CN-ZONE
CN-DISPLAY
CN-CC

SPEC.
Fan motor output
Fan motor output
Discharge pipe sensor
Suction pipe sensor
Room sensor
Remote controller
Float switch input
EEV output
Drain pump output
Option PWB.
Communication
Drain pump output
AC power supply
Zone Controller
RF Remote controller
Dry contact

DESCRIPTION
Motor output of BLDC
Motor output of BLDC
Pipe out thermistor
Pipe in thermistor
Room thermistor
Remote control line
Float switch sensing
EEV control output
AC output for drain pump
Communication between main and option
Communication between indoor and outdoor
AC output for drain pump
AC power line input for indoor controller
Zone control line
RF remote control line
Dry contact line

Dip Switch Setting


SW3
GROUP

Off
Master

On
Slave

SW4

DRY CONTACT

Variable

Auto

SW5

EXTRA 1

Off

On

Remarks
Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

Ceiling Concealed Duct


- Low Static

Indoor unit

5-6

6. Capacity Tables
Ceiling Concealed Duct- Low Static

6.1 Cooling Capacity

Capacity
Index

2.2

2.8

3.6

Outdoor
air temp.
(DB, C)
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

Notes:
TC: Total Capacity(kW)

5-7

Cooling capacity

20
14
TC SHC
kW kW

23
16
TC SHC
kW kW

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6

2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6

2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.2
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
2.9
2.9
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.7
3.7

1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.6
1.6
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.0
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.6
2.6

30
22
TC SHC
kW
kW
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.5
2.5
2.5
2.4
2.4
2.3
2.3
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.3
3.2
3.2
3.1
3.1
3.0
3.0
2.9
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.2
4.1
4.1
4.0
4.0
3.9
3.8
3.7

1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.6
1.6
1.6
1.6
1.5
1.5
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.1
2.1
2.1
2.0
2.0
1.9
1.9
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.7
2.7
2.6
2.6
2.6
2.5
2.5

32
24
TC SHC
kW kW
2.9
2.9
2.8
2.8
2.7
2.7
2.7
2.6
2.6
2.6
2.5
2.5
2.5
2.4
2.4
2.3
3.7
3.6
3.6
3.5
3.5
3.4
3.4
3.4
3.3
3.3
3.2
3.2
3.1
3.1
3.0
3.0
4.7
4.7
4.6
4.6
4.5
4.4
4.4
4.3
4.3
4.2
4.2
4.1
4.0
4.0
3.9
3.8

1.7
1.7
1.7
1.6
1.6
1.6
1.6
1.6
1.5
1.5
1.5
1.5
1.5
1.4
1.4
1.4
2.2
2.1
2.1
2.1
2.1
2.0
2.0
2.0
2.0
1.9
1.9
1.9
1.9
1.8
1.8
1.8
2.8
2.8
2.7
2.7
2.7
2.6
2.6
2.6
2.5
2.5
2.5
2.4
2.4
2.3
2.3
2.3

SHC: Sensible Heat Capacity(kW)

Indoor unit

Ceiling Concealed Duct


- Low Static

Cooling capacity

4.5

5.6

7.1

Outdoor
air temp.
(DB, C)
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

20
14
TC SHC
kW kW

23
16
TC SHC
kW kW

3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8

3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7

4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6

Notes:
TC: Total Capacity(kW)

Ceiling Concealed Duct


- Low Static

2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1

3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6

3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0

4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1

3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0

4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
5.8
5.7
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.4
7.2

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.0
3.9
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.1
5.0

30
22
TC SHC
kW
kW
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.6
6.4
6.4
6.3
6.2
6.0
5.9
5.8
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.4
8.2
8.1
8.0
7.8
7.7
7.5
7.4

3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.2
4.1
4.1
4.0
3.9
3.9
3.8
3.7
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.2
5.2
5.1
5.0
4.9
4.8
4.7

32
24
TC SHC
kW kW
5.9
5.8
5.8
5.7
5.6
5.5
5.5
5.4
5.3
5.3
5.2
5.1
5.0
5.0
4.9
4.8
7.4
7.3
7.2
7.1
7.0
6.9
6.8
6.7
6.6
6.6
6.5
6.4
6.3
6.2
6.1
6.0
9.3
9.2
9.1
9.0
8.8
8.7
8.7
8.5
8.4
8.3
8.2
8.1
7.9
7.8
7.7
7.6

3.5
3.5
3.4
3.4
3.3
3.3
3.3
3.2
3.2
3.1
3.1
3.0
3.0
2.9
2.9
2.8
4.2
4.2
4.1
4.1
4.0
4.0
3.9
3.9
3.8
3.8
3.7
3.7
3.6
3.5
3.5
3.4
5.4
5.3
5.2
5.2
5.1
5.0
5.0
4.9
4.8
4.8
4.7
4.6
4.6
4.5
4.4
4.4

SHC: Sensible Heat Capacity(kW)

Indoor unit

5-8

Ceiling Concealed Duct- Low Static

Capacity
Index

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

Ceiling Concealed Duct- Low Static

6.2 Heating Capacity


Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

Heating capacity
Indoor air temp. (DB, C)

16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

kW

kW

kW

kW

kW

kW

2.2

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.3
2.4
2.5
2.6
2.8
2.8
2.9
2.9
2.9
2.9
2.9

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.3
2.4
2.5
2.6
2.7
2.7
2.7
2.7
2.7
2.7
2.7

1.7
1.7
1.8
1.7
1.8
1.9
1.9
2.0
2.0
2.1
2.2
2.3
2.4
2.5
2.5
2.5
2.5
2.5
2.5

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.2
2.3
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.2
2.3
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

1.7
1.7
1.8
1.9
2.0
2.1
2.1
2.1
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

2.8

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

2.1
2.2
2.3
2.5
2.6
2.7
2.8
2.8
2.9
3.0
3.2
3.4
3.6
3.6
3.7
3.7
3.7
3.7
3.7

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.9
3.0
3.2
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

2.1
2.2
2.3
2.2
2.3
2.4
2.5
2.5
2.6
2.7
2.8
3.0
3.1
3.2
3.2
3.2
3.2
3.2
3.2

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.8
3.0
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.8
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0

2.1
2.2
2.3
2.4
2.6
2.7
2.7
2.7
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8

3.6

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

2.7
2.8
2.9
3.1
3.2
3.4
3.4
3.5
3.6
3.8
4.0
4.2
4.4
4.5
4.6
4.6
4.6
4.6
4.6

2.7
2.8
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.8
4.0
4.2
4.3
4.3
4.3
4.3
4.3
4.3
4.3

2.7
2.8
2.9
2.7
2.9
3.0
3.1
3.2
3.3
3.4
3.5
3.7
3.9
4.0
4.0
4.0
4.0
4.0
4.0

2.6
2.8
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.7
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9

2.6
2.7
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.7
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8

2.6
2.7
2.9
3.0
3.2
3.4
3.4
3.4
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5

Notes:
TC: Total Capacity(kW)

5-9

Indoor unit

Ceiling Concealed Duct


- Low Static

Heating capacity

4.5

5.6

7.1

Indoor air temp. (DB, C)


16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

kW

kW

kW

kW

kW

kW

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7
-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

3.4
3.5
3.7
3.9
4.1
4.3
4.3
4.4
4.6
4.8
5.0
5.3
5.6
5.6
5.8
5.8
5.8
5.8
5.8
4.2
4.3
4.6
4.9
5.1
5.4
5.4
5.5
5.7
6.0
6.2
6.6
7.0
7.1
7.2
7.2
7.2
7.2
7.2

3.4
3.5
3.7
3.8
4.1
4.3
4.3
4.4
4.6
4.8
5.0
5.3
5.4
5.4
5.4
5.4
5.4
5.4
5.4
4.2
4.3
4.6
4.8
5.1
5.4
5.4
5.5
5.7
6.0
6.2
6.6
6.7
6.7
6.7
6.7
6.7
6.7
6.7

3.4
3.5
3.7
3.4
3.6
3.8
3.9
4.0
4.1
4.3
4.4
4.6
4.9
5.0
5.0
5.0
5.0
5.0
5.0
4.2
4.3
4.6
4.3
4.5
4.8
4.9
5.0
5.1
5.4
5.5
5.8
6.2
6.3
6.3
6.3
6.3
6.3
6.3

3.3
3.5
3.7
3.8
4.0
4.3
4.3
4.4
4.4
4.6
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.2
4.3
4.6
4.8
5.0
5.4
5.4
5.5
5.6
5.8
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1

3.3
3.4
3.7
3.8
4.0
4.2
4.3
4.4
4.4
4.6
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.2
4.3
4.6
4.8
5.0
5.3
5.4
5.5
5.6
5.8
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9

3.3
3.4
3.6
3.8
4.0
4.2
4.3
4.3
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.2
4.3
4.5
4.8
5.0
5.3
5.4
5.4
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

5.4
5.5
5.8
6.2
6.5
6.8
6.9
7.0
7.3
7.6
7.9
8.4
8.9
9.0
9.2
9.2
9.2
9.2
9.2

5.4
5.5
5.8
6.1
6.5
6.8
6.9
7.0
7.3
7.6
7.9
8.4
8.6
8.6
8.6
8.6
8.6
8.6
8.6

5.4
5.5
5.8
5.5
5.8
6.0
6.2
6.3
6.5
6.8
7.0
7.4
7.8
8.0
8.0
8.0
8.0
8.0
8.0

5.3
5.5
5.8
6.1
6.4
6.8
6.9
7.0
7.1
7.4
7.7
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8

5.3
5.4
5.8
6.1
6.4
6.7
6.9
7.0
7.1
7.4
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5

5.3
5.4
5.8
6.1
6.4
6.7
6.8
6.8
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0

Notes:
TC: Total Capacity(kW)

Ceiling Concealed Duct


- Low Static

Indoor unit

5-10

Ceiling Concealed Duct- Low Static

Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

7. External Static Pressure (E.S.P) & Air Flow


Ceiling Concealed Duct- Low Static

ARNU07GB1G2, ARNU09GB1G2, ARNU12GB1G2, ARNU15GB1G2


Setting Value
60
65
70
75
80
85
90
95
100
105
110
115

Static Pressure(mmAq(Pa))
0(0)
6.02
6.95
7.69
8.46
9.5
10.35
10.81
11.57
12.58
13.31
14.2
14.82

1(10)
2.25
3.32
5.16
6.93
7.37
8.72
9.66
10.31
11.22
12.27
13.24
13.92

2(20)

3(29)

4(39)

0.61
0.73
1.19
2.42
3.4
5.33
6.75
8.56
9.75
10.89
12.15
12.64

0.54
0.65
0.77
0.87
1.35
3.15
4.73
7.46
8.64
10.49
11.16

0.48
0.56
0.63
0.72
0.88
0.98
1.03
2.31
5.01
7.7
9.48

ARNU18GB2G2, ARNU24GB2G2
Setting Value
65
70
75
80
85
90
95
100
105
110
115
120
125
130

(Unit: CMM)

(Unit: CMM)
Static Pressure(mmAq(Pa))

0(0)

1(10)

2(20)

3(29)

4(39)

10.07
11.39
12.01
13.21
14.24
15.04
16.02
17.11
17.99
19.04
19.77
20.94
21.97
22.83

6.9
8.49
9.79
11.03
12.36
13.34
14.63
15.56
16.53
17.71
18.62
19.92
20.56
21.98

0.82
2.2
4.2
5.92
9.41
10.8
12.5
13.66
15.17
16.22
17.1
18.56
19.25
20.75

0.92
2.1
5.29
7.59
11.53
12.35
14.23
15.23
16.98
17.68
19.32

1.01
1.34
5.35
7.67
10.45
13.25
14.66
16.06
17.73

Note :
1. The above table shows the correlation between the air rates and E.S.P.

5-11

Indoor unit

Ceiling Concealed Duct


- Low Static

ARNU07GB1G2, ARNU09GB1G2, ARNU12GB1G2, ARNU15GB1G2

7k

High
(factory set)
Standard

9k

Standard
Set value ESP(mmAq(Pa))

Mode

High
(factory set)
Standard
High
(factory set)

12k
Standard
High
(factory set)
15k
Standard

HI
Mid
Low
HI
Mid
Low
HI
Mid
Low
HI
Mid
Low
HI
Mid
Low
HI
Mid
Low
HI
Mid
Low
HI
Mid
Low

94
92
86
75
69
62
99
94
92
82
75
69
103
99
94
89
80
75
107
105
99
95
89
82

2(20)
0(0)
2(20)
0(0)
2(20)
0(0)
2(20)
0(0)

CMM

Lower Limit of External


Static Pressure(mmAq(Pa))

8.5
7.5
6.5
8.5
7.5
6.5
9.5
8.5
7.5
9.5
8.5
7.5
10.5
9.5
8.5
10.5
9.5
8.5
11.5
10.5
9.5
11.5
10.5
9.5

Upper Limit of External


Static Pressure(mmAq(Pa))

4(39)

4(39)

4(39)

4(39)

4(39)

4(39)

4(39)

4(39)

ARNU18GB2G2, ARNU24GB2G2
Capacity

18k

High
(factory set)
Standard

24k

Standard
Set value ESP(mmAq(Pa))

Mode

High
(factory set)
Standard

HI
Mid
Low
HI
Mid
Low
HI
Mid
Low
HI
Mid
Low

Ceiling Concealed Duct


- Low Static

110
101
93
95
84
75
125
115
105
110
100
90

2(20)
0(0)
2(20)
0(0)

CMM

Lower Limit of External


Static Pressure(mmAq(Pa))

16
14
12
16
14
12
19
17
15
19
17
15

Indoor unit

Upper Limit of External


Static Pressure(mmAq(Pa))

4(39)

4(39)

4(39)

4(39)

5-12

Ceiling Concealed Duct- Low Static

Capacity

8. Electric Characteristics
Units
Ceiling Concealed Duct- Low Static

Model

Type

Power Supply
Hz

Volts

Voltage Range MCA

IFM

Input(W)

MFA

kW

FLA

Cooling Heating

ARNU07GB1G2

B1

1.22

15

0.028

0.17

30

30

ARNU09GB1G2

B1

1.22

15

0.028

0.17

30

30

ARNU12GB1G2

B1

Max:264

1.22

15

0.028

0.17

30

30

ARNU15GB1G2

B1

Min:198

1.22

15

0.028

0.17

30

30

ARNU18GB2G2

B2

1.55

15

0.076

0.44

80

80

ARNU24GB2G2

B2

1.55

15

0.076

0.44

80

80

ARNU07GB1G2

B1

1.22

15

0.028

0.17

30

30

ARNU09GB1G2

B1

1.22

15

0.028

0.17

30

30

ARNU12GB1G2

B1

Max:242

1.22

15

0.028

0.17

30

30

ARNU15GB1G2

B1

Min:198

1.22

15

0.028

0.17

30

30

ARNU18GB2G2

B2

1.55

15

0.076

0.44

80

80

ARNU24GB2G2

B2

1.55

15

0.076

0.44

80

80

50

60

220~240

220

Symbols:
MCA : Min, Circuit Amps(A)
MFA : Max. Fuse Amps(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amps(A)
IFM : Indoor Fan Motor
Note :
1. Voltage range
Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above
the listed range limits,
2. Maximum allowable voltage unbalance between phases is 2%
3. MCA/MFA
MCA=1.25 x FLA + 1
MFA 4 x FLA
(Next lower standard fuse rating. Min. 15A)
4. Select wire size based on the MCA
5. Instead of fuse, use Circuit Breaker.

5-13

Indoor unit

Ceiling Concealed Duct


- Low Static

9. Sound Levels
Overall

1.5m

Ceiling
2.0m

Ceiling Concealed Duct- Low Static

Notes:
- Sound measured at 1.5m away from the center of the unit.
- Data is valid at free field condition
- Data is valid at nominal operating condition
- Reference accoustic pressure OdB = 20Pa
- Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment is installed.

Microphone

Model Name
ARNU07GB1G2
ARNU09GB1G2
ARNU12GB1G2
ARNU15GB1G2
ARNU18GB2G2
ARNU24GB2G2

Sound Levels dB(A)


H
M
35
33
36
35
37
36
38
37
40
37
43
40

L
31
33
35
36
34
37

Sound Pressure Level


ARNU09GB1G2

70

70

70

NC-65

60

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30

NC-50
NC-45

40

NC-40
NC-35

30

NC-30

NC-20
10

NC-15
125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)

63

NC-55

50

NC-25
Approximate
Hearing
Threshold
63

ARNU15GB1G2

250

500

NC-60
NC-55
NC-50
NC-45
NC-40
NC-35

30

NC-30
NC-25

20
Approximate
Hearing
Threshold
63

NC-15
1000 2000 4000 8000

NC-45
NC-40
NC-35

30

NC-30

10

NC-25
Approximate
Hearing
Threshold
63

NC-20

125

250

500

NC-15
1000 2000 4000 8000

Octave Band Center Frequency (Hz)

ARNU24GB2G2
80

70

NC-65

60

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
NC-25

20
Approximate
Hearing
Threshold

NC-20

NC-15
125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)

Ceiling Concealed Duct


- Low Static

Octave Band Sound Pressure Level (dB re 20Pa )

NC-65

40

NC-50

ARNU18GB2G2

70

50

NC-55

40

NC-20

80

60

NC-60
50

Octave Band Center Frequency (Hz)

80

10

125

NC-65

60

20

10
63

Octave Band Sound Pressure Level (dB re 20Pa )

10

NC-60

20

NC-25
Approximate
Hearing
Threshold

NC-65

60

Octave Band Sound Pressure Level (dB re 20Pa )

80

20

Octave Band Sound Pressure Level (dB re 20Pa )

ARNU12GB1G2

80

Octave Band Sound Pressure Level (dB re 20Pa )

Octave Band Sound Pressure Level (dB re 20Pa )

ARNU07GB1G2
80

70

NC-60

125 250 500 1000 2000 4000 8000


Octave Band Center Frequency (Hz)

Indoor unit

NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
NC-25

20

NC-20
NC-15

NC-65

60

10

Approximate
Hearing
Threshold
63

NC-20
NC-15

125 250 500 1000 2000 4000 8000


Octave Band Center Frequency (Hz)

5-14

Ceiling Concealed Duct- Low Static

10. Installation
Please read the instruction sheets completely before installing the product.
When the power cord is damaged, replacement work shall be performed by authorized personnel only.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Required Parts

Required Tools

Connecting cable
Pipes: Gas side
Liquid side
Hanging Bolt
(W 3/8 or M10 length 650mm)
Insulated drain hose
Additional Drain hose

Level
Screw driver
Electric drill
Hole core drill
Flaring Tool set
Torque Wrenches
Hexagonal Wrench
Gas-leak detector
Thermometer

10.1 Selection of the best location


Install the air conditioner in the location that satisfies
the
following conditions.
The place shall easily bear a load exceeding four
times the indoor units weight.
The place shall be able to inspect the unit as given in
the
figure.
The place where the unit shall be leveled.
The place shall allow easy water drainage.(Suitable
dimension H is necessary to get a slope to drain as
figure.)
The place shall easily connect with the outdoor unit.
The place where the unit is not affected by an electrical noise.
The place where air circulation in the room will be
good .
There should not be any heat source or steam near
the unit.
The servicing inspection hole in the ceiling should be
as large as the product.
The selection of the servicing hole should be
approved by the customer.

[Inspection Hole Standard]


Number of
Inspection hole

Distance between
False ceiling & Actual ceiling

More than 100cm

20cm to 100cm

Hole size should be


more than the size of IDU.

Less than 20cm

Remarks
Sufficient space in the
ceiling for servicing.
Insufficient space.
Difficult for servicing
Minimum height for
motor replacement.

Inspection hole
(600X600)
Control box

Top view
(unit: mm)

600

600

Front view

5-15

Indoor unit

Ceiling Concealed Duct


- Low Static

Ceiling Concealed Duct- Low Static

10.2 Ceiling dimension and hanging bolt


location
Installation of Unit
Install the unit above the ceiling correctly.

CASE 1
POSITION OF SUSPENSION BOLT
Apply a joint-canvas between the unit and duct to absorb
unnecessary vibration.

M10 Nut

X4

M10 washer

X4

M10 washer

X4

M10 Nut

X8

Install the unit leaning to a drainage hole side as a figure


for easy water drainage.

CASE 2
POSITION OF CONSOLE BOLT
A place where the unit will be leveled and that can support the weight of the unit.
A place where the unit can withstand its vibration.
A place where service can be easily performed.

NOTE:
Throughly study the following installation locations:
1. In such places as restaurants and kitchens, considerable amount of oil steam and flour adhere to the fan, the fin of the heat
exchanger, resulting in heat exchange reduction, spraying, dispersing of water drops, etc.
In these cases, take the following actions:
Make sure that the ventilation fan for smoke-collecting hood on a cooking table has sufficient capacity so that it draws oily
steam which should not flow into the suction of the air conditioner.
Make enough distance from a cooking room to install the air conditioner in such a place where it may not suck in oil steam.
2. Avoid installing air conditioner in such circumstances where cutting oil mist or iron powder is in suspension in factories, etc.
3. Avoid places where inflammable gas is generated, flows in, is stored or vented.
4. Avoid places where sulfurous acid gas or corrosive gas is generated.
5. Avoid places near high frequency generators.

Ceiling Concealed Duct


- Low Static

Indoor unit

5-16

Spray one or two glasses of water on the evaporator.


Ensure that water flows drain hose of indoor unit without any leakage.

10.4 Indoor Unit Drain Piping


Upward
routing
not allowed

Drain piping must have down-slope (1/50 to 1/100): be sure not to pro- Pipe clamp
vide up-and-down slope to prevent reversal flow.
During drain piping connection, be careful not to exert extra force on the
Indoor unit
drain port on the indoor unit.
The outside diameter of the drain connection on the indoor unit is 32mm.
Maintenance
drain port

Piping material: Polyvinyl chloride pipe inner


diometes 25mm and pipe fittings
Be sure to install heat insulation on the drain piping.

1/50~1/100

Heat insulation material: Polyethylene foam with


thickness more than 8 mm.

MAX 700mm

Drain test
The air conditioner uses a drain pump to drain water.
Use the following procedure to test the drain pump operation:
Feed water

Flexible drain hose


(accessory)
Main
drain pipe

Drain Pump

Drain
port

Glue the joint

Drain hose connection


Use the clip (accessory)

Connect the main drain pipe to the exterior and leave it provisionally until the test comes to an end.
Feed water to the flexible drain hose and check the piping
for leakage.
Be sure to check the drain pump for normal operating and
noise when electrical wiring is complete.
When the test is complete, connect the flexible drain hose to
the drain port on the indoor unit.

Drain pan

Max 300mm

CAUTION
The supplied flexible drain hose should not be strained.
A strained hose may cause leakage of water.

Hanger
distance
1~15m

Hanger Bracket
1/50~1/100 slope

Metal
clamp
Flexible drain hose

Max 700mm

Ceiling Concealed Duct- Low Static

10.3 Checking the Drainage

Insulation

Flexible drain hose

5-17

Ceiling
Concealed Duct
Flexible drain hose
Indoor unit
Flexible drain hose
- Low Static

10.5 Ground drain piping

Face the vent pipe mouth downward to keep


foreign matter from penetrating the system
Face piping
downward
Vent pipe

b) The pipe work should be kept as short as possible and the number of indoor units per group kept to a
minimum.

10.6 Use of an auxiliary drain hose(flexible)


a) To connect drain pipe to the drain socket on the indoor unit, an auxiliary flexible drain hose should be
used. auxiliary flexible drain hose allows that the drain pipe can be connected to the socket without breaking by excessive strain.
Auxiliary drain hose

Thermal insulation (drain pipe area)

Metal clamp

Metal clamp
Thermal insulation(bend area)
Drain pan

Important points
- The drain pipe should be at least equal in size to that of the indoor unit.
- The drain pipe is thermally insulated to prevent the formation of condensation inside the pipe.
- The drain up mechanism should be fitted before the indoor unit is installed and when the electricity has
been connected some water should be added to the drain pan and the drain pump to check and see if it
is functioning correctly.
- All connections should be secure. (Special care is needed with PVC pipe)
- Insulate auxiliary drain hose with thermal insulation band.

Ceiling Concealed Duct


- Low Static

Indoor unit

5-18

Ceiling Concealed Duct- Low Static

a) It is standard work practice to make connections to the main pipe from above. The pipe down from the
combination should be as large as possible.

Ceiling Concealed Duct- Low Static

WIRED REMOTE CONTROLLER INSTALLATION


Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.

Do not install the remote controller where it can be affected by:


- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)

TEMP

yes

Remote Controller

no

TEMP

Controller
Remote

TEMP

Remote Controller

5feet
(1.5meters)

no

no

Fig.1 Typical locations for remote controller

5-19

Indoor unit

Ceiling Concealed Duct


- Low Static

11. Accessories
Standard Accessories
Drain hose

Clamp metal

Quantity

1 EA

2 EA

Washer for
hanging backet
8 EA

Clamp
(Tie Wrap)

Insulation for
fitting

(Other)

1 SET

4 EA

Owner's manual
Installation manual
Shape

for gas pipe

for liquid pipe

CAUTION
Use only those accessories (Standard or optional) which have designated specifications.

Ceiling Concealed Duct


- Low Static

Indoor unit

5-20

Ceiling Concealed Duct- Low Static

Name

Ceiling Concealed Duct- Built in

Ceiling Concealed Duct


(Built in)
1. List of functions
2. Specifications
3. Dimensions
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. External Static Pressure (E.S.P) & Air Flow
8. Electric Characteristics
9. Sound Levels
10. Installation
11. Accessories

Indoor unit

Ceiling Concealed Duct


- Built in

1. List of Functions
Function

Air flow

Air purifying

Installation

Reliability

Convenience

Individual
control

Special
function kit

Air supply outlet


Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Wide wired remote controller
Deluxe wired remote controller
Simple wired remote controller
Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
Zone control
CTIE
Electro thermostat

Ceiling Concealed Duct- Built in

Category

ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
1
3/3/3
X
X
O
O
O
X
O
O
O
O(Heat recovery)
X
O(Heat pump or Cooling only)
O
O
O
O
O
O
O
Accessory
Accessory
Accessory
Accessory
X
Accessory
Accessory
-

O : Applied
X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

Ceiling Concealed Duct


- Built in

Indoor unit

6-1

Ceiling Concealed Duct- Built in

2. Specification
Ceiling Concealed Duct (Built-in)
PBSGB30/PBSC30
PBSGB30/PBSC30
PBSGB30/PBSC30
Unit
ARNU07GB3G2
ARNU09GB3G2
ARNU12GB3G2
kW
2.2
2.8
3.6
Cooling Capacity
kcal/h
1,900
2,400
3,100
Btu/h
7,500
9,600
12,300
kW
2.5
3.2
4.0
Heating Capacity
kcal/h
2,200
2,800
3,400
Btu/h
8,500
10,900
13,600
Casing
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
mm
820 x 575 x 190
820 x 575 x 190
820 x 575 x 190
Dimensions(WxDxH) Body
inch
32.3x22.6x7.5
32.3x22.6x7.5
32.3x22.6x7.5
Rows
x
Columns
x
FPI
2x11x21
2x11x21
2x11x21
Coil
Face Area
m2
0.16
0.16
0.16
Type
Sirocco Fan
Sirocco Fan
Sirocco Fan
Motor Output x Number
W
30
30
30
Running Current
A
0.15
0.15
0.15
Air Flow Rate(H/M/L)
CMM
8/6.5/5.5
9/7/6
10/8/6.5
(High Mode-factor set)
cfm
283/229/194
318/247/212
353/283/229
Fan
External Static Pressure mmAq(Pa)
2(20)
2(20)
2(20)
Air Flow Rate(H/M/L)
CMM
8/6.5/5.5
9/7/6
10/8/6.5
(Standard Mode)
cfm
283/229/194
318/247/212
353/283/229
External Static Pressure mmAq(Pa)
0(0)
0(0)
0(0)
Drive
Direct
Direct
Direct
Motor type
BLDC
BLDC
BLDC
Temperature Control
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material
Foamed polystrene
Foamed polystrene
Foamed polystrene
Air Filter
Safety Device
Fuse, Thermal Fuse for Fan Motor Fuse, Thermal Fuse for Fan Motor Fuse, Thermal Fuse for Fan Motor
Liquid Side
mm(inch)
6.35(1/4)
6.35(1/4)
6.35(1/4)
Pipe Connections Gas Side
mm(inch)
12.7(1/2)
12.7(1/2)
12.7(1/2)
Drain Pipe(Internal Dia.)
mm
25.4
25.4
25.4
Net Weight
kg(lbs)
21(46.3)
21(46.3)
21(46.3)
Noise Level(Sound Press, 1m, H/M/L)
dB(A)3
37/34/33
39/35/34
40/37/34
1,
220
~
240,
50
1,
220
~
240,
50
1,
220
~ 240, 50
Power Supply
, V, Hz
1, 220, 60
1, 220, 60
1, 220, 60
Refrigerant Control
EEV
EEV
EEV
Power cable
mm2
CV1.5 x 3C
CV1.5 x 3C
CV1.5 x 3C
Transmission cable
mm2
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
Type
Accessory
Model

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification
4. EEV: Electronic Expansion Valve
5. To be added for more available Models

6-2

Indoor unit

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

Ceiling Concealed Duct


- Built in

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification
4. EEV: Electronic Expansion Valve
5. To be added for more available Models

Ceiling Concealed Duct


- Built in

Indoor unit

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

6-3

Ceiling Concealed Duct- Built in

Ceiling Concealed Duct (Built-in)


PBSGB30/PBSC30
PBSGB40/PBSC40
PBSGB40/PBSC40
Unit
ARNU15GB3G2
ARNU18GB4G2
ARNU24GB4G2
kW
4.5
5.6
7.1
Cooling Capacity
kcal/h
3,900
4,800
6,100
Btu/h
15,400
19,100
24,200
kW
5.0
6.3
8.0
Heating Capacity
kcal/h
4,300
5,400
6,900
Btu/h
17,100
21,500
27,300
Casing
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
mm
820 x 575 x 190
1,100 x 575 x 190
1,100 x 575 x 190
Dimensions(WxDxH) Body
inch
32.3x22.6x7.5
32.3x22.6x7.5
32.3x22.6x7.5
Rows
x
Columns
x
FPI
2x11x21
3x10x18
3x10x18
Coil
Face Area
m2
0.16
0.23
0.23
Type
Sirocco Fan
Sirocco Fan
Sirocco Fan
Motor Output x Number
W
30
80
80
Running Current
A
0.15
0.38
0.38
Air Flow Rate(H/M/L)
CMM
11/10/8
14/12/10
17/15/10
(High Mode-factor set)
cfm
388/353/283
494/424/353
600/530/353
Fan
External Static Pressure mmAq(Pa)
2(20)
2(20)
2(20)
Air Flow Rate(H/M/L)
CMM
11/10/8
14/12/10
17/15/10
(Standard Mode)
cfm
388/353/283
494/424/353
600/530/353
External Static Pressure mmAq(Pa)
0(0)
0(0)
0(0)
Drive
Direct
Direct
Direct
Motor type
BLDC
BLDC
BLDC
Temperature Control
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material
Foamed polystrene
Foamed polystrene
Foamed polystrene
Air Filter
Safety Device
Fuse, Thermal Fuse for Fan Motor Fuse, Thermal Fuse for Fan Motor Fuse, Thermal Fuse for Fan Motor
Liquid Side
mm(inch)
6.35(1/4)
6.35(1/4)
9.52(3/8)
Pipe Connections Gas Side
mm(inch)
12.7(1/2)
12.7(1/2)
15.88(5/8)
Drain Pipe(Internal Dia.)
mm
25.4
25.4
25.4
Net Weight
kg(lbs)
21(46.3)
26(57.3)
26(57.3)
Noise Level(Sound Press, 1m, H/M/L)
dB(A)3
41/40/37
43/40/37
46/43/37
1,
220
~
240,
50
1,
220
~
240,
50
1,
220
~ 240, 50
Power Supply
, V, Hz
1, 220, 60
1, 220, 60
1, 220, 60
Refrigerant Control
EEV
EEV
EEV
Power cable
mm2
CV1.5 x 3C
CV1.5 x 3C
CV1.5 x 3C
Transmission cable
mm2
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
Type
Accessory
Model

Indoor unit

With Suction Grille


& Suction Canvas

575

B3/B4

With Suction Grille & Suction Canvas

250

618

388

PBSC30
PBSC40

PBSGB30
PBSGB40

E
821
1100

B
910
1188

Btu/h
A
7,9,12,15k 820
18,24k
1100
D
56
56
F
G
274 42~250
274 42~250

C
359
359

With Suction Grille

Name

(unit : mm)
Unit size(7k,9k,12k,15k,18k):6.35
Unit size(24k):9.52
Unit size(7k,9k,12k,15k,18k):12.7
Unit size(24k):15.88

Descripition

CHASSIS CODE: B3/B4

Air suction
Air discharge

Drain pipe connection


Power supply connection

Gas pipe connection

Liquid pipe connection

60

190

3
4

Number

65

ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)

Ceiling Concealed Duct (Built in)

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Note

500(Max)

277

With Suction Grille

388
190

216
24

6-4
190

Ceiling Concealed Duct- Built in

3. Dimensions

Ceiling Concealed Duct


- Built in

4. Piping Diagrams

EEV
Filter

Ceiling Concealed Duct- Built in

Heat Exchanger

:Cooling
:Heating

Th2

Th3
Sirocco Fan

Th1

Filter

lndoor unit

Refrigerant pipe connection port diameter


[Unit: mm(inch)]

MODEL

GAS

LIQUID

ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)

12.7(1/2)

6.35(1/4)

ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)

12.7(1/2)

6.35(1/4)

ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)

12.7(1/2)

6.35(1/4)

ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)

12.7(1/2)

6.35(1/4)

ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)

12.7(1/2)

6.35(1/4)

ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)

15.88(5/8)

9.52(3/8)

LOC.

Description

Th1

Room thermistor

Th2

Pipe in thermistor

Th3

Pipe out thermistor

Ceiling Concealed Duct


- Built in

Indoor unit

6-5

5. Wiring Diagrams

Ceiling Concealed Duct- Built in

B3/B4 Chassis

CONNECTOR NUMBER
CN-MOTOR1
CN-MOTOR2
CN-PIPE/OUT
CN-PIPE/IN
CN-ROOM
CN-REMO
CN-FLOAT
CN-EEV
CN-D/PUMP
CN-OPTION
CN-COM
CN-D/PUMP
CN-POWER
CN-ZONE
CN-DISPLAY
CN-CC

SPEC.

DESCRIPTION

Fan motor output


Fan motor output
Discharge pipe sensor
Suction pipe sensor
Room sensor
Remote controller
Float switch input
EEV output
Drain pump output
Option PWB.
Communication
Drain pump output
AC power supply
Zone Controller
RF Remote controller
Dry contact

Motor output of BLDC


Motor output of BLDC
Pipe out thermistor
Pipe in thermistor
Room thermistor
Remote control line
Float switch sensing
EEV control output
AC output for drain pump
Communication between main and option
Communication between indoor and outdoor
AC output for drain pump
AC power line input for indoor controller
Zone control line
RF remote control line
Dry contact line

Dip Switch Setting


SW3
GROUP

Off
Master

On
Slave

SW4

DRY CONTACT

Variable

Auto

SW5

EXTRA 1

Off

On

Remarks
Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

6-6

Indoor unit

Ceiling Concealed Duct


- Built in

6. Capacity Tables
6.1 Cooling Capacity

23
16
TC SHC
kW kW

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6

2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6

2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.2

1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.6
1.6

2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.5
2.5
2.5
2.4
2.4
2.3
2.3

1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.6
1.6
1.6
1.6
1.5
1.5

2.9
2.9
2.8
2.8
2.7
2.7
2.7
2.6
2.6
2.6
2.5
2.5
2.5
2.4
2.4
2.3

1.7
1.7
1.7
1.6
1.6
1.6
1.6
1.6
1.5
1.5
1.5
1.5
1.5
1.4
1.4
1.4

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9

1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6

2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6

3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
2.9
2.9
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.7
3.7

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.0
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.6
2.6

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.3
3.2
3.2
3.1
3.1
3.0
3.0
2.9
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.2
4.1
4.1
4.0
4.0
3.9
3.8
3.7

2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.1
2.1
2.1
2.0
2.0
1.9
1.9
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.7
2.7
2.6
2.6
2.6
2.5
2.5

3.7
3.6
3.6
3.5
3.5
3.4
3.4
3.4
3.3
3.3
3.2
3.2
3.1
3.1
3.0
3.0
4.7
4.7
4.6
4.6
4.5
4.4
4.4
4.3
4.3
4.2
4.2
4.1
4.0
4.0
3.9
3.8

2.2
2.1
2.1
2.1
2.1
2.0
2.0
2.0
2.0
1.9
1.9
1.9
1.9
1.8
1.8
1.8
2.8
2.8
2.7
2.7
2.7
2.6
2.6
2.6
2.5
2.5
2.5
2.4
2.4
2.3
2.3
2.3

Outdoor
air temp.
(DB, C)

2.2

3.6

Notes:
TC: Total Capacity(kW)

Ceiling Concealed Duct


- Built in

30
22
TC SHC
kW
kW

32
24
TC SHC
kW kW

SHC: Sensible Heat Capacity(kW)

Indoor unit

6-7

Ceiling Concealed Duct- Built in

20
14
TC SHC
kW kW

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

Capacity
Index

2.8

Cooling capacity

Ceiling Concealed Duct- Built in

Cooling capacity

20
14
TC SHC
kW kW

23
16
TC SHC
kW kW

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0

2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7

3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6

3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0

4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2

3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2

4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5

3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3

4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4

3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5

5.9
5.8
5.8
5.7
5.6
5.5
5.5
5.4
5.3
5.3
5.2
5.1
5.0
5.0
4.9
4.8

3.5
3.5
3.4
3.4
3.3
3.3
3.3
3.2
3.2
3.1
3.1
3.0
3.0
2.9
2.9
2.8

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8

3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1

4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7

3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6

5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6

3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0

5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1

4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0

6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
5.8
5.7
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.4
7.2

4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.0
3.9
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.1
5.0

6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.6
6.4
6.4
6.3
6.2
6.0
5.9
5.8
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.4
8.2
8.1
8.0
7.8
7.7
7.5
7.4

4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.2
4.1
4.1
4.0
3.9
3.9
3.8
3.7
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.2
5.2
5.1
5.0
4.9
4.8
4.7

7.4
7.3
7.2
7.1
7.0
6.9
6.8
6.7
6.6
6.6
6.5
6.4
6.3
6.2
6.1
6.0
9.3
9.2
9.1
9.0
8.8
8.7
8.7
8.5
8.4
8.3
8.2
8.1
7.9
7.8
7.7
7.6

4.2
4.2
4.1
4.1
4.0
4.0
3.9
3.9
3.8
3.8
3.7
3.7
3.6
3.5
3.5
3.4
5.4
5.3
5.2
5.2
5.1
5.0
5.0
4.9
4.8
4.8
4.7
4.6
4.6
4.5
4.4
4.4

Capacity
Index

Outdoor
air temp.
(DB, C)

4.5

5.6

7.1

Notes:
TC: Total Capacity(kW)

6-8

30
22
TC SHC
kW
kW

32
24
TC SHC
kW kW

SHC: Sensible Heat Capacity(kW)

Indoor unit

Ceiling Concealed Duct


- Built in

6.2 Heating Capacity


Indoor air temp. (DB, C)
16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

kW

kW

kW

kW

kW

kW

2.2

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.3
2.4
2.5
2.6
2.8
2.8
2.9
2.9
2.9
2.9
2.9

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.3
2.4
2.5
2.6
2.7
2.7
2.7
2.7
2.7
2.7
2.7

1.7
1.7
1.8
1.7
1.8
1.9
1.9
2.0
2.0
2.1
2.2
2.3
2.4
2.5
2.5
2.5
2.5
2.5
2.5

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.2
2.3
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.2
2.3
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

1.7
1.7
1.8
1.9
2.0
2.1
2.1
2.1
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

2.8

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

2.1
2.2
2.3
2.5
2.6
2.7
2.8
2.8
2.9
3.0
3.2
3.4
3.6
3.6
3.7
3.7
3.7
3.7
3.7

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.9
3.0
3.2
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

2.1
2.2
2.3
2.2
2.3
2.4
2.5
2.5
2.6
2.7
2.8
3.0
3.1
3.2
3.2
3.2
3.2
3.2
3.2

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.8
3.0
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.8
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0

2.1
2.2
2.3
2.4
2.6
2.7
2.7
2.7
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8

3.6

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

2.7
2.8
2.9
3.1
3.2
3.4
3.4
3.5
3.6
3.8
4.0
4.2
4.4
4.5
4.6
4.6
4.6
4.6
4.6

2.7
2.8
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.8
4.0
4.2
4.3
4.3
4.3
4.3
4.3
4.3
4.3

2.7
2.8
2.9
2.7
2.9
3.0
3.1
3.2
3.3
3.4
3.5
3.7
3.9
4.0
4.0
4.0
4.0
4.0
4.0

2.6
2.8
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.7
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9

2.6
2.7
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.7
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8

2.6
2.7
2.9
3.0
3.2
3.4
3.4
3.4
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5

Ceiling Concealed Duct- Built in

Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

Heating capacity

Notes:
TC: Total Capacity(kW)

Ceiling Concealed Duct


- Built in

Indoor unit

6-9

Ceiling Concealed Duct- Built in

Heating capacity
Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

4.5

5.6

7.1

Indoor air temp. (DB, C)


16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

kW

kW

kW

kW

kW

kW

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7
-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

3.4
3.5
3.7
3.9
4.1
4.3
4.3
4.4
4.6
4.8
5.0
5.3
5.6
5.6
5.8
5.8
5.8
5.8
5.8
4.2
4.3
4.6
4.9
5.1
5.4
5.4
5.5
5.7
6.0
6.2
6.6
7.0
7.1
7.2
7.2
7.2
7.2
7.2

3.4
3.5
3.7
3.8
4.1
4.3
4.3
4.4
4.6
4.8
5.0
5.3
5.4
5.4
5.4
5.4
5.4
5.4
5.4
4.2
4.3
4.6
4.8
5.1
5.4
5.4
5.5
5.7
6.0
6.2
6.6
6.7
6.7
6.7
6.7
6.7
6.7
6.7

3.4
3.5
3.7
3.4
3.6
3.8
3.9
4.0
4.1
4.3
4.4
4.6
4.9
5.0
5.0
5.0
5.0
5.0
5.0
4.2
4.3
4.6
4.3
4.5
4.8
4.9
5.0
5.1
5.4
5.5
5.8
6.2
6.3
6.3
6.3
6.3
6.3
6.3

3.3
3.5
3.7
3.8
4.0
4.3
4.3
4.4
4.4
4.6
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.2
4.3
4.6
4.8
5.0
5.4
5.4
5.5
5.6
5.8
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1

3.3
3.4
3.7
3.8
4.0
4.2
4.3
4.4
4.4
4.6
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.2
4.3
4.6
4.8
5.0
5.3
5.4
5.5
5.6
5.8
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9

3.3
3.4
3.6
3.8
4.0
4.2
4.3
4.3
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.2
4.3
4.5
4.8
5.0
5.3
5.4
5.4
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

5.4
5.5
5.8
6.2
6.5
6.8
6.9
7.0
7.3
7.6
7.9
8.4
8.9
9.0
9.2
9.2
9.2
9.2
9.2

5.4
5.5
5.8
6.1
6.5
6.8
6.9
7.0
7.3
7.6
7.9
8.4
8.6
8.6
8.6
8.6
8.6
8.6
8.6

5.4
5.5
5.8
5.5
5.8
6.0
6.2
6.3
6.5
6.8
7.0
7.4
7.8
8.0
8.0
8.0
8.0
8.0
8.0

5.3
5.5
5.8
6.1
6.4
6.8
6.9
7.0
7.1
7.4
7.7
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8

5.3
5.4
5.8
6.1
6.4
6.7
6.9
7.0
7.1
7.4
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5

5.3
5.4
5.8
6.1
6.4
6.7
6.8
6.8
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0

Notes:
TC: Total Capacity(kW)

6-10

Indoor unit

Ceiling Concealed Duct


- Built in

7. External Static Pressure (E.S.P) & Air Flow

Setting Value

(Unit: CMM)

Static Pressure(mmAq(Pa))
0(0)

1(10)

2(20)

3(29)

4(39)

60

6.29

3.03

0.93

65

6.61

4.84

1.52

70

7.69

5.64

2.18

0.79

75

8.19

6.28

2.81

0.85

80

8.91

7.43

4.96

1.58

85

9.51

8.14

5.91

2.75

0.95

90

10.21

8.76

6.79

3.41

1.36

95

10.83

9.62

8.11

5.48

2.61

100

11.31

10.55

9.02

6.12

3.31

105

11.84

11.19

9.99

8.28

5.32

110

12.68

11.88

10.38

9.16

6.92

115

13.19

12.22

11.55

10.21

8.23

ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
Setting Value

(Unit: CMM)

Static Pressure(mmAq(Pa))
0(0)

1(10)

2(20)

3(29)

4(39)

75

10.32

7.68

3.55

80

11.06

8.77

4.71

1.38

85

11.84

10.02

6.95

2.16

90

12.73

10.74

8.26

4.73

1.25

95

13.47

12.13

9.93

6.74

2.73

100

14.16

13.25

10.51

8.41

3.65

105

15.29

14.11

12.31

9.83

6.21

110

16.09

14.77

13.49

10.39

8.32

115

16.91

15.88

14.48

12.77

9.92

120

17.81

16.88

15.15

13.98

10.85

125

18.55

17.84

16.12

15.13

12.97

130

19.01

18.55

17.33

16.28

14.59

Note :
1. The above table shows the correlation between the air rates and E.S.P.
2. E.S.P. is given after subtracting coil losses motor step factory installed
3. E.S.P. can be higher than the maximum given in the table, but the unit faces the problem of freezing the coil.

Ceiling Concealed Duct


- Built in

Indoor unit

6-11

Ceiling Concealed Duct- Built in

ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)

Ceiling Concealed Duct- Built in

ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
Capacity

7k

High
(factory set)
Standard

9k

Standard
Set value ESP(mmAq(Pa))

Mode

High
(factory set)
Standard
High
(factory set)

12k
Standard
High
(factory set)
15k
Standard

HI
Mid
Low
HI
Mid
Low
HI
Mid
Low
HI
Mid
Low
HI
Mid
Low
HI
Mid
Low
HI
Mid
Low
HI
Mid
Low

94
88
83
74
62
56
99
89
85
82
66
58
105
94
88
90
74
62
110
105
94
96
90
74

2(20)
0(0)
2(20)
0(0)
2(20)
0(0)
2(20)
0(0)

CMM

Lower Limit of External


Static Pressure(mmAq(Pa))

8
6.5
5.5
8
6.5
5.5
9
7
6
9
7
6
10
8
6.5
10
8
6.5
11
10
8
11
10
8

Upper Limit of External


Static Pressure(mmAq(Pa))

4(39)

4(39)

4(39)

4(39)

4(39)

4(39)

4(39)

4(39))

ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
Capacity

18k

High
(factory set)
Standard

24k

High
(factory set)
Standard

6-12

Standard
Set value ESP(mmAq(Pa))

Mode
HI
Mid
Low
HI
Mid
Low
HI
Mid
Low
HI
Mid
Low

115
103
93
100
86
74
128
118
93
116
104
74

2(20)
0(0)
2(20)
0(0)

CMM

Lower Limit of External


Static Pressure(mmAq(Pa))

14
12
10
14
12
10
17
15
10
17
15
10

Indoor unit

Upper Limit of External


Static Pressure(mmAq(Pa))

4(39)

4(39)

4(39)

4(39)

Ceiling Concealed Duct


- Built in

8. Electric Characteristics
Units

Power Supply

Input(W)

kW

FLA

1.22

15

0.028

0.17

30

30

1.22

15

0.028

0.17

30

30

Max:264

1.22

15

0.028

0.17

30

30

Min:198

1.22

15

0.028

0.17

30

30

B4

1.55

15

0.076

0.44

80

80

ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)

B4

1.55

15

0.076

0.44

80

80

ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)

B3

1.22

15

0.028

0.17

30

30

ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)

B3

1.22

15

0.028

0.17

30

30

ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)

B3

Max:242

1.22

15

0.028

0.17

30

30

ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)

B3

Min:198

1.22

15

0.028

0.17

30

30

ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)

B4

1.55

15

0.076

0.44

80

80

ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)

B4

1.55

15

0.076

0.44

80

80

Type

ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)

B3

ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)

B3

ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)

B3

ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)

B3

ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)

Hz

50

60

220~240

220

Cooling Heating

Symbols:
MCA : Min, Circuit Amps(A)
MFA : Max. Fuse Amps(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amps(A)
IFA : Indoor Fan Motor
Note :
1. Voltage range
Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above
listed range limits,
2. Maximum allowable voltage unbalance between phases is 2%
3. MCA/MFA
MCA=1.25 x FLA + 1
MFA 4 x FLA
(Next lower standard fuse rating. Min. 15A)
4. Select wire size based on the MCA
5. Instead of fuse, use Circuit Breaker.

Ceiling Concealed Duct


- Built in

Indoor unit

6-13

Ceiling Concealed Duct- Built in

MFA

Model

Volts Voltage Range MCA

IFM

9. Sound Levels

Ceiling Concealed Duct- Built in

Overall
Notes:
- Sound measured at 1.5m away from the center of the unit.
- Data is valid at free field condition
- Data is valid at nominal operation condition
- Reference accoustic pressure OdB = 20Pa
- Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment is installed.

1.5m

Ceiling
2.0m
Microphone

Sound Levels dB(A)


H
M
37
34
39
35
40
37
41
40
43
40
46
43

Model Name
ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)

L
33
34
34
37
37
37

Sound Pressure Level

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
20

10

63

80

70

70

NC-60

250

500

NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30

NC-20

125

NC-65

60

20

NC-25
Approximate
Hearing
Threshold

80

NC-15
1000 2000 4000 8000

10

NC-25
Approximate
Hearing
Threshold
63

Octave Band Center Frequency (Hz)

70

70

NC-65
NC-60
NC-55
NC-50
NC-45
NC-40
NC-35

30

NC-30
20

10

NC-25
Approximate
Hearing
Threshold
63

125

250

500

250

500

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
20

10

NC-25
Approximate
Hearing
Threshold
63

NC-15
1000 2000 4000 8000

NC-20

125

250

NC-15
1000 2000 4000 8000

500

Octave Band Center Frequency (Hz)

ARNU24GB4G2+
PBSGB40(Acc'y), PBSC40(Acc'y)
80

70

NC-65

60

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
20

NC-65
60
NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30

NC-25

NC-25

20

NC-20

Octave Band Center Frequency (Hz)

6-14

Octave Band Sound Pressure Level (dB re 20Pa )

Octave Band Sound Pressure Level (dB re 20Pa )

80

40

125

NC-55

50

ARNU18GB4G2+
PBSGB40(Acc'y), PBSC40(Acc'y)

80

50

NC-60

NC-20
NC-15
1000 2000 4000 8000

NC-65

60

Octave Band Center Frequency (Hz)

ARNU15GB3G2+
PBSGB30(Acc'y), PBSC30(Acc'y)

60

Octave Band Sound Pressure Level (dB re 20Pa )

NC-65

60

Octave Band Sound Pressure Level (dB re 20Pa )

Octave Band Sound Pressure Level (dB re 20Pa )

70

ARNU12GB3G2+
PBSGB30(Acc'y), PBSC30(Acc'y)

Octave Band Sound Pressure Level (dB re 20Pa )

80

ARNU09GB3G2+
PBSGB30(Acc'y), PBSC30(Acc'y)

ARNU07GB3G2+
PBSGB30(Acc'y), PBSC30(Acc'y)

10

Approximate
Hearing
Threshold
63

Approximate
Hearing
Threshold

NC-20

125

250

500

1000

2000

4000

NC-15
8000

NC-20
NC-15

10

Octave Band Center Frequency (Hz)

63

125

250

500

1000 2000

4000

8000

Octave Band Center Frequency (Hz)

Indoor unit

Ceiling Concealed Duct


- Built in

10. Installation

Suction Grille
TEMP

Remote Controller

Suction Grille +
Suction Canvas

TEMP

Remote Controller

Required Parts

Required Tools

Connecting cable
Pipes: Gas side
Liquid side
Hanging Bolt
(W 3/8 or M10 length 650mm)
Insulated drain hose
Additional Drain hose
(Inner Dia ....................................25mm)

Level
Screw driver
Electric drill
Hole core drill (70mm)
Flaring Tools set
Torque Wrenches
Hexagonal Wrench (4mm, 5mm)
Gas-leak detector
Owners Manual
Thermometer

Ceiling Concealed Duct


- Built in

Indoor unit

6-15

Ceiling Concealed Duct- Built in

Please read this instruction sheet completely before installing the product.
When the power cord is damaged, replacement work shall be performed by authorized personnel only.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Install the air conditioner in the location that satisfies the


following conditions.

Top view
(unit:mm)
Airflow

The place shall easily bear a load exceeding four times


the indoor units weight.

Inspection hole
(600 x 600)

The place shall be able to inspect the unit as the figure.

Control box

The place where the unit shall be leveled.


The place shall easily connect with the outdoor unit.
600

The place where the unit is not affected by an electrical


noise.

600

There should not be any heat source or steam near the


unit
Confirm the positional relationship between the unit and
suspension bolts.

270 or more

The place where air circulation in the room will be good .

Installation the ceiling opening to clean the filter or service under the product.

(Unit : mm)
Chassis

B3

600

900

B4

600

1100

520 or more

Ceiling Concealed Duct- Built in

10.1 Selection of the best location

Refer to Suction grille and Suction canvas installation


manual for detail installation of Built-in duct type

A(Min)

B3/B4 Series : Built-in Duct type

B(Min)

Ceiling
Service Space

6-16

Indoor unit

Ceiling Concealed Duct


- Built in

10.2 Ceiling dimension and hanging bolt location


Ceiling Concealed Duct- Built in

Installation of Unit
B
A
J

Install the unit above the ceiling correctly.

CASE 1

C
D

POSITION OF SUSPENSION BOLT

Apply a joint-canvas between the unit and duct to absorb


unnecessary vibration.
G

Apply a filter Accessory at air return hole.


(Unit:mm)

I
F

Dimension

850 900 383 575


1130 1180 383 575

93
93

190
190

Chassis

B3
B4

H
21 795 163 820
21 1065 163 1100

Drainage hole

Drain Pump use

M10 Nut

X4

M10 washer

X4

M10 washer

X4

M10 Nut

X8

CASE 2
Install the unit leaning to a drainage hole side as a figure
for easy water drainage.

POSITION OF CONSOLE BOLT


A place where the unit will be leveled and that can support
the weight of the unit.
A place where the unit can withstand its vibration.
A place where service can be easily performed.

Ceiling Concealed Duct


- Built in

Indoor unit

6-17

Insert the set anchor and washer onto the suspension bolts for locking the suspension bolts on the
ceiling.
Mount the suspension bolts to the set anchor firmly.
Secure the installation plates onto the suspension
bolts (adjust level roughly) using nuts, washers and
spring washers.

Ceiling Concealed Duct- Built in

Select and mark the position for fixing bolts.


Drill the hole for set anchor on the face of ceiling.

Old building

New building

1 Set anchor
2 Plate washer
3 Spring washer
4 Nut

CAUTION

5 Suspension
bolts

Tighten the nut and bolt to prevent unit falling.

10.3 Connecting Cables


Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively
Terminal Block Indoor
1(L)

2(N)

SODU

INTERNET DRY1 DRY2 GND 12V

IDU

Outdoor
Unit

INDOOR POWER INPUT

WARNING
Make sure that the screws of the terminal are not from loose.

Clamping of cables
1) Arrange 2 power cables on the control panel.
2) First, fasten the steel clamp with a screw to the inner boss of control panel.
3) For the cooling model, fix the other side of the clamp with a screw strongly. For the heat pump model, put the
0.75mm2 cable(thinner cable) on the clamp and tighten it with a plastic clamp to the other boss of the control
panel.

6-18

Indoor unit

Ceiling Concealed Duct


- Built in

10.4 Part name and functions


Ceiling Concealed Duct- Built in

Air outlet

Air outlet

Suction Grille
Suction Grille
Suction Canvas

Buit-in duct type with Suction Grille

Buit-in duct type with Suction Grille and Suction


Canvas

B3/B4 Series : Built-in Duct type Control Box service

Ceiling Concealed Duct


- Built in

Indoor unit

6-19

Ceiling Concealed Duct- Built in

INSULATION, OTHERS
THERMAL INSULATION

Insulate the joint and tubes completely.

All thermal insulation must comply with local requirement.

INDOOR UNIT
Union for gas pipe

Refrigerant pipe and thermal


insulator(Local supply)

Thermal insulator for refrigerant pipe


(Local supply) Thermal insulator for
piping(Local supply)

Hose clip for thermal insulator


(Local supply)
Overlap with thermal
insulator for piping.
Hose clip for thermal insulator(Local supply)
Make sure that there is no clearance here.

Thermal insulator for refrigerant pipe


(Local supply)
Union for liquid pipe

Felt

Cabinet

Rubber

Insulation
No clearance

TEST AND CHECK

After all workings are finished, check the working and operation.
Air distribution ............... Is the air circulation good?
Drain ............................. Is the drainage smoothly and no sweating?
Gas leakage ................. Is the piping connection correctly?
Wiring ........................... Is the wiring connection correctly?
Lock-bolt ....................... Is the lock-bolt of compressor loosened?
Insulation
Is the unit fully insulated?
Ground
Is the unit safely grounded?

10.5 Checking the Drainage


1. Remove the Air Filter.

6-20

2. Check the drainage.


Spray one or two glasses of water upon the
evaporator.
Ensure that water flows drain hose of indoor unit
without any leakage.

Indoor unit

Ceiling Concealed Duct


- Built in

CAUTION
Ceiling Concealed Duct- Built in

1. Install declination of the indoor unit is very important for the drain of the duct type air conditioner.
2. Minimum thickness of the insulation for the connecting pipe shall be 19mm.

Front of view
The unit must be horizontal or declined to the drain hose connected when finished
installation.

Ceiling
Drainage hole

Drain Pump use

10.6 Drain Piping


Drain piping must have down-slope (1/50 to 1/100): be sure not to
provide up-and-down slope to prevent reversal flow.
During drain piping connection, be careful not to exert extra force
on the drain port on the indoor unit.
The outside diameter of the drain connection on the indoor unit is
32mm.

Pipe clamp
Indoor unit

Piping material: Polyvinyl chloride pipe VP-25 and


pipe fittings

Upward
routing
not allowed

Maintenance
drain port

Be sure to install heat insulation on the drain piping.


Heat insulation material: Polyethylene foam with thickness more than 8 mm.

1/50~1/100
MAX 700mm

Drain test
The air conditioner uses a drain pump to drain water.
Use the following procedure to test the drain pump operation:

Feed water

Flexible drain hose


Main
drain pipe

Drain Pump

Drain
port

Glue the joint

Drain hose connection


Use the clip

Connect the main drain pipe to the exterior and


leave it provisionally until the test comes to an
end.
Feed water to the flexible drain hose and check
the piping for leakage.
Be sure to check the drain pump for normal operating and noise when electrical wiring is complete.
When the test is complete, connect the flexible
drain hose to the drain port on the indoor unit.

Drain pan

Ceiling Concealed Duct


- Built in

Indoor unit

6-21

Max 300mm

Hanger
distance
1~15m

Metal
clamp
Flexible drain hose

Hanger Bracket
1/50~1/100 slope
Max 700mm

Ceiling Concealed Duct- Built in

CAUTION : The supplied flexible drain


hose should not be curved, neither
screwed. The curved or screwed hose
may cause a leakage of water.

Insulation

CAUTION:
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have an individual power specialized for the air conditioner. As for the method of
wiring, be guided by the circuit diagram posted on the inside of control box cover.
2) Provide a circuit breaker switch between power source and the unit.
3) The screws which fasten the wiring in the casing of electrical fittings are liable to come loose
from vibrations to which the unit is subjected during the course of transportation. Check them
and make sure that they are all tightly fastened. (If they are loose, it could give rise to burn-out
Flexible drain hose
of the wires.)
4) Specification of power source
5) Confirm that electrical capacity is sufficient.
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage
marked on the name plate.
7) Confirm that the cable thickness is as specified in the power sources specification.
(Particularly note the relation between cable length and thickness.)
8) Never fail to equip a leakage breaker where it is wet or moist.
9) The following troubles would be caused by voltage drop-down.
Vibration of a magnetic switch, damage on the contact point, fuse breaking, disturbance by the normal function of an overload protection device.
Proper starting power is not given to the compressor.

HAND OVER
Teach the customer the operation and maintenance procedures, using the operation manual.
(air filter cleaning, temperature control, etc.)

6-22

Indoor unit

Ceiling Concealed Duct


- Built in

WIRED REMOTE CONTROLLER INSTALLATION

Do not install the remote controller where it can be affected by:


- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)

TEMP

yes

Remote Controller

no

TEMP

Controller
Remote

TEMP

Remote Controller

5feet
(1.5meters)

no

no

Fig.1 Typical locations for remote controller

Ceiling Concealed Duct


- Built in

Indoor unit

6-23

Ceiling Concealed Duct- Built in

Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.

11. Accessories

Ceiling Concealed Duct- Built in

Standard Accessories
Name

Drain hose

Clamp metal

Quantity

1 EA

2 EA

Washer for
hanging backet
8 EA

Clamp
(Tie Wrap)

Insulation for
fitting

4 EA

1 SET

(Other)

Owner's manual
Installation manual
Shape

for gas pipe

for liquid pipe

CAUTION
Use only those accessories (Standard or optional) which have designated specilications.

6-24

Indoor unit

Ceiling Concealed Duct


- Built in

1. List of functions
2. Specifications
3. Dimensions
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. Air Velocity and Temperature Distribution
8. Electric Characteristics
9. Sound Levels
10. Installation
11. Accessories

Wall Mounted

Indoor unit

Wall Mounted

Wall Mounted

1. List of functions

Wall Mounted

Category

Air flow

Air purifying

Installation

Reliability

Convenience

Individual
control

Special
function kit

Function
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Wide wired remote controller
Deluxe wired remote controller
Simple wired remote controller
Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
Zone control
CTIE
Electro thermostat

ARNU07GSE*2, ARNU09GSE*2, ARNU12GSE*2


ARNU15GSE*2, ARNU18GS5*2, ARNU24GS5*2
1
SE Manual / S5 Auto
Auto
SE Manual / S5 Auto
X
3/4/3
O
O
O
X
Option
O
O
O
O
O(Heat recovery)
O
O(Heat pump or Cooling only)
O
O
O
O
O
O
O
O
Accessory
Accessory
Accessory
Accessory
Accessory
Accessory
-

O : Applied
X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

7-1

Indoor unit

Wall Mounted

2. Specifications
* Model Name
A:Basic L:Plasma
Type
Model
Cooling Capacity

Dimensions(WxDxH) Body
Coil

Fan

Rows x Columns x FPI


Face Area
Type
Motor Output x Number
Running Current
Air Flow Rate(H/M/L)

m2
W
A
CMM
cfm

Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side
mm(inch)
Pipe Connections Gas Side
mm(inch)
Drain Pipe(Internal Dia.)
mm
Net Weight
kg(lbs)
Noise Level(Sound Press, 1m, H/M/L)
dB(A)3
Power Supply
Refrigerant Control
Power cable
Transmission cable
Color

, V, Hz
mm2
mm2

Wall Mounted
ARNU07GSE*2
ARNU09GSE*2
ARNU12GSE*2
2.2
2.8
3.6
1,900
2,400
3,100
7,500
9,600
12,300
2.5
3.2
4.0
2,200
2,800
3,400
8,500
10,900
13,600
895x165x282
895x165x282
895x165x282
35.2x6.5x11.1
35.2x6.5x11.1
35.2x6.5x11.1
2x15x18
2x15x18
2x15x18
0.21
0.21
0.21
Cross Flow Fan
Cross Flow Fan
Cross Flow Fan
20
20
20
0.20
0.20
0.20
5.6/5/4.6
7/ 6.5 /6
9.5/ 9/8.5
198/177/162.5
247/230/212
336/318/300
Direct
Direct
Direct
BLDC
BLDC
BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene
Foamed polystrene
Foamed polystrene
Resin Net(washable)
Resin Net(washable)
Resin Net(washable)
Fuse
Fuse
Fuse
6.35(1/4)
6.35(1/4)
6.35(1/4)
12.7(1/2)
12.7(1/2)
12.7(1/2)
16
16
16
9(19.8)
9(19.8)
9(19.8)
37/33/23
39/35/25
41/36/27
1, 220 ~ 240, 50
1, 220 ~240, 50
1, 220 ~240, 50
1, 220, 60
1, 220, 60
1, 220, 60
EEV
EEV
EEV
CV1.5 x 3C
CV1.5 x 3C
CV1.5 x 3C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
Morning fog
Morning fog
Morning fog

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve

Wall Mounted

Indoor unit

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

7-2

Wall Mounted

Heating Capacity

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h
mm
inch

Wall Mounted

* Model Name
A:Basic L:Plasma
Type
Model
Cooling Capacity

Heating Capacity
Dimensions(WxDxH) Body
Coil

Fan

Rows x Columns x FPI


Face Area
Type
Motor Output x Number
Running Current
Air Flow Rate(H/M/L)

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h
mm
inch
m2
W
A
CMM
cfm

Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side
mm(inch)
Pipe Connections Gas Side
mm(inch)
Drain Pipe(Internal Dia.)
mm
Net Weight
kg(lbs)
Noise Level(Sound Press, 1m, H/M/L)
dB(A)3
Power Supply
Refrigerant Control
Power cable
Transmission cable
Color

, V, Hz
mm2
mm2

Wall Mounted
ARNU15GSE*2
ARNU18GS5*2
ARNU24GS5*2
4.5
5.6
7.1
3,900
4,800
6,100
15,400
19,100
24,200
5.0
6.3
8.0
4,300
5,400
6,900
17,100
21,500
27,300
895x165x282
1,090x178x300
1,090x178x300
35.2x6.5x11.1
42.9x7x11.8
42.9x7x11.8
2x15x18
2x15x20
2x15x20
0.21
0.26
0.26
Cross Flow Fan
Cross Flow Fan
Cross Flow Fan
20
20
20
0.20
0.20
0.20
10.5/9/8.5
12/10.5/9
14/13/10
371/318/300
424/371/318
494/459/353
Direct
Direct
Direct
BLDC
BLDC
BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene
Foamed polystrene
Foamed polystrene
Resin Net(washable)
Resin Net(washable)
Resin Net(washable)
Fuse
Fuse
Fuse
6.35(1/4)
6.35(1/4)
9.52(3/8)
12.7(1/2)
12.7(1/2)
15.88(5/8)
16
16
16
9(19.8)
12(26.5)
12(26.5)
42/36/27
44/40/36
46/41/38
1, 220 ~240, 50
1, 220 ~ 240, 50
1, 220 ~ 240, 50
1, 220, 60
1, 220, 60
1, 220, 60
EEV
EEV
EEV
CV1.5 x 3C
CV1.5 x 3C
CV1.5 x 3C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
Morning fog
Morning fog
Morning fog

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve

7-3

Indoor unit

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

Wall Mounted

Indoor unit
567

895

Air discharge grill


Air suction grill

1
2

282

Descripition

(unit : mm)

165

(unit : mm)

282

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

CHASSIS CODE: SE

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Note

Name

895

ARNU07GSE*2
ARNU09GSE*2
ARNU12GSE*2
ARNU15GSE*2

Number

Wall Mounted

Wall Mounted
Model

ARNU07GSE*2
ARNU09GSE*2
ARNU12GSE*2
ARNU15GSE*2

Wall Mounted

3. Dimensions

7-4

265

165

7-5

Indoor unit

Wall Mounted

804

1,090

281

300

Air discharge grill


Air suction grill

1
2

300

Descripition

(unit : mm)

178

(unit : mm)

CHASSIS CODE: S5

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Note

Name

1090

ARNU18GS5*2
ARNU24GS5*2

Number

Model

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

178

ARNU18GS5*2
ARNU24GS5*2

Wall Mounted

Wall Mounted

4. Piping Diagrams

Heat Exchanger

EEV
Filter

Th3

:Cooling
:Heating

Th2

C.F.F

Wall Mounted

Th1

Filter

lndoor unit

Refrigerant pipe connection port diameter


[Unit: mm(inch)]

Wall Mounted

MODEL

GAS

LIQUID

ARNU07GSE*2

12.7(1/2)

6.35(1/4)

ARNU09GSE*2

12.7(1/2)

6.35(1/4)

ARNU12GSE*2

12.7(1/2)

6.35(1/4)

ARNU15GSE*2

12.7(1/2)

6.35(1/4)

ARNU18GS5*2

12.7(1/2)

6.35(1/4)

ARNU24GS5*2

15.88(5/8)

9.52(3/8)

LOC.

Description

Th1

Room thermistor

Th2

Pipe in thermistor

Th3

Pipe out thermistor

Indoor unit

7-6

Wall Mounted

5. Wiring Diagrams

7-7

Indoor unit

Wall Mounted

Tighten the flare nut with a wrench.

Wall Mounted

Spanner (fixed)
Flare nut
Connection
pipe

Torque
wrench

Wrap the area which accommodates the rear piping housing section with vinyl tape.
Indoor
unit pipe
Wrap with vinyl tape

Connection
pipe
Vinyl tape
(wide)

Connecting cable

Indoor
unit tubing

Pipe

When extending the drain hose at the indoor unit,


install the drain pipe.

Drain pipe

Vinyl tape(narrow)

Bundle the piping and drain hose together by


wrapping them with vinyl tape over the range within which they fit into the rear piping housing section.
Wrap with vinyl tape

Indoor unit
drain hose
Vinyl tape(narrow)

Pipe

Adhesive

Vinyl tape(wide)
Drain hose

6. Wrap the insulation material around the connecting portion.


Overlap the connection pipe insulation material
and the indoor unit pipe insulation material. Bind
them together with vinyl tape so that there is no
gap.

Plastic bands

For right rear piping


1. Route the indoor tubing and the drain hose to the
required piping hole position.

Insulation material

2. Insert the piping, drain hose and the connecting


cable into the piping hole.
Connecting
cable

Drain pipe

7-19

Indoor unit

Wall Mounted

3. Insert the connecting cable into the indoor unit.


Don't connect the cable to the indoor unit.
Make a small loop with the cable for easy connection later.

When extending the drain hose at the indoor unit,


install the drain pipe.

Drain hose

4. Tape the drain hose and the connecting cable.


Connecting cable
Indoor unit drain hose

7. Wrap the insulation material around the connecting portion.


Overlap the connecting pipe heat insulation and the
indoor unit pipe heat insulation material. Bind them
together with vinyl tape so that there is no gap.
5. Indoor unit installation
Hang the indoor unit from the hooks at the top of
the installation plate.
Insert the spacer etc. between the indoor unit and
the installation plate and separate the bottom of the
indoor unit from the wall.

Plastic bands

Insulation material

Wrap the area which accommodates the rear piping


housing section with vinyl tape.

Indoor unit
Spacer

Connection
pipe

Installation plate

Vinyl tape
(wide)

8cm

6. Connecting the pipings to the indoor unit and the


drain hose to drain pipe.
Align the center of the pipings and sufficiently tighten the flare nut by hand.

Indoor unit tubing

Flare nut

Indoor
unit piping
Wrap with vinyl tape
Pipe

Connecting
cable

Vinyl tape
(narrow)

Pipings

Tighten the flare nut with a wrench.


Spanner (fixed)

Torque
wrench

Flare nut
Connection
pipe

Indoor
unit tubing

Wall Mounted

Indoor unit

7-20

Wall Mounted

Vinyl tape(narrow)
Adhesive

Wall Mounted

Bundle the piping and drain hose together by wrapping them with cloth tape over the range within
which they fit into the rear piping housing section.

10. Indoor unit installation


Remove the spacer.
Ensure that the hooks are properly seated on the
installation plate by moving it left and right.

Pipe
Drain hose

Vinyl tape
(narrow)

Connecting
cable

Wrap with
vinyl tape(wide)

8. Reroute the pipings and the drain hose across the


back of the chassis.

Drain hose

Press the lower left and right sides of the unit against
the installation plate until the hooks engage into their
slots(clicking sound).

Piping for
passage through
piping hole

9. Set the pipings and the drain hose to the back of


the chassis with the tubing holder.
Hook the edge of tubing holder to tap on chassis
and push the bottom of tubing holder to be
engaged at the bottom of chassis.

Tubing holder
1 Hook

2 Push

7-21

Indoor unit

Wall Mounted

10.2 Connection of Pipings


2. To check the drainage.
Pour a glass of water on the evaporator.
Ensure the water flows through the drain hose of the
indoor unit without any leakage and goes out the
drain exit.
Wall Mounted

1. To remove the front panel from the indoor unit,


remove the front panel from the indoor unit
cabinet.
Set the air direction louvers up-and-down to the
position(horizontally) by hand.
Remove the securing screws that retain the front
panel. Pull the lower left and right sides of the grille
toward you and lift it off.
(2.1/7, 2.6/9, 3.5/12 kW/Btu models: 2EA,
3.5/18 kW/Btu models: 3EA)

Pull the right and


the left side.

Screw

10.3 Connect the cable to the


indoor unit
1. Connect the wires to the terminals on the
control board individually according to the
outdoor unit connection.
Ensure that the color of the wires of outdoor
unit and the terminal No. are the same as those
of indoor unit respectively.

Remote control
co
cord

Connecting cable

Wall Mounted

Indoor unit

7-22

Terminal Block Indoor

Wall Mounted

1(L)

2(N)

SODU

INTERNET DRY1 DRY2 GND 12V

IDU
-

Outdoor
Unit

INDOOR POWER INPUT

2. Attach the Grille onto the cabinet.


Grasp lower the left and right side of the Grille
and engage four tabs on the top inside edge of
the chassis.
Press the Grille toward the chassis until it is
back in place.

CAUTION
After the confirmation of the above conditions, prepare the wiring as follows:
1) As for the method of wiring, follow the circuit diagram posted on the inside of control cover.
2) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from
vibrations to which the unit is subjected during the course of transportation. Check them and
make sure that they are all tightly fastened. (If they are loose, it could cause burn-out of the
wires.)
3) Confirm the specification of power source.
4) Confirm that electrical capacity is sufficient.
5) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked
on the name plate.
6) Confirm that the cable thickness is as specified in the power source specification.
(Particularly note the relation between the cable length and thickness.)
7) In a wet or moist area, always install an earth leakage circuit breaker.
8) The following would be caused by voltage drop.
Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the
normal function of the overload.
9) The means for disconnection from a power supply shall be incorporated in the fixed wiring and
have an air gap contact separation of at least 3mm in each active(phase) conductor.

7-23

Indoor unit

Wall Mounted

WIRED REMOTE CONTROLLER INSTALLATION


Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place away
from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.

Do not install the remote controller where it can be affected by:

TEMP

Wall Mounted

- Drafts, or dead spots behind doors and in corners.


- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)

yes

Remote Controller

no

TEMP

Controller
Remote

TEMP

Remote Controller

5feet
(1.5meters)

no

no

Fig.1 Typical locations for remote controller

Wall Mounted

Indoor unit

7-24

11. Accessories

Wall Mounted

Standard Accessories
Name

Installation panel

Type "A" screw

Quantity

1 set

SE: 6 EA
S5: 8 EA

(Other)
Owner's manual
Installation manual

SE

Shape
S5

CAUTION
Use only those accessories (Standard or optional) which have designated specifications.

7-25

Indoor unit

Wall Mounted

1. List of functions
2. Specifications
3. Dimensions
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. Air Velocity and Temperature Distribution
8. Electric Characteristics
9. Sound Levels
10. Installation
11. Accessories

ART COOL Mirror

Indoor unit

ART COOL Mirror

ART COOL Mirror

ART COOL Mirror

1. List of functions
Category

Air flow

Air purifying

Installation

Reliability

Convenience

Individual
control

Special
function kit

Function
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Wide wired remote controller
Deluxe wired remote controller
Simple wired remote controller
Wired remote controller(for hotel use)
Wireless LCD remote control
Zone control
CTIE
Electro thermostat

ARNU07GSE*2, ARNU09GSE*2, ARNU12GSE*2


ARNU15GSE*2, ARNU18GS8*2, ARNU24GS8*2
1
Auto
Auto
Auto
X
3/4/3
O
O
O
X
Option
O
O
O
O
O(Heat recovery)
O
O(Heat pump or Cooling only)
O
O
O
O
O
O
O
O
Accessory
Accessory
Accessory
Accessory
Accessory
-

O : Applied
X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

8-1

Indoor unit

ART COOL Mirror

2. Specifications
Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h
mm
inch

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve

ART COOL Mirror

Indoor unit

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

8-2

ART COOL Mirror

ART COOL Mirror


ARNU07GSE*2
ARNU09GSE*2
ARNU12GSE*2
2.2
2.8
3.6
1,900
2,400
3,100
Cooling Capacity
7,500
9,600
12,300
2.5
3.2
4.0
2,200
2,800
3,400
Heating Capacity
8,500
10,900
13,600
915x169x282
915x169x282
915x169x282
Dimensions(WxDxH) Body
36.0x6.5x11.1
36.0x6.5x11.1
36.0x6.5x11.1
2x15x18
2x15x18
2x15x18
Rows
x
Columns
x
FPI
Coil
0.21
0.21
0.21
Face Area
m2
Cross Flow Fan
Cross Flow Fan
Cross Flow Fan
Type
20
20
20
Motor Output x Number
W
0.20
0.20
0.20
Running Current
A
7/6/4
8/7/5
10/8/6
Fan
Air Flow Rate(H/M/L)
CMM
247/212/141
282/247/177
353/283/212
cfm
Direct
Direct
Direct
Drive
BLDC
BLDC
BLDC
Motor type
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Temperature Control
Foamed polystrene
Foamed polystrene
Foamed polystrene
Sound Absorbing Thermal Insulation Material
Resin Net(washable)
Resin Net(washable)
Resin Net(washable)
Air Filter
Fuse
Fuse
Fuse
Safety Device
6.35(1/4)
6.35(1/4)
6.35(1/4)
Liquid Side
mm(inch)
12.7(1/2)
12.7(1/2)
12.7(1/2)
Pipe Connections Gas Side
mm(inch)
16
16
16
Drain Pipe(Internal Dia.)
mm
11.2(24.7)
11.2(24.7)
11.2(24.7)
Net Weight
kg(lbs)
37/33/23
39/35/25
41/36/27
Noise Level(Sound Press, 1m, H/M/L)
dB(A)3
1, 220 ~ 240, 50
1, 220 ~240, 50
1, 220 ~240, 50
Power Supply
, V, Hz
1, 220, 60
1, 220, 60
1, 220, 60
EEV
EEV
EEV
Refrigerant Control
CV1.5 x 3C
CV1.5 x 3C
CV1.5 x 3C
Power cable
mm2
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
Transmission cable
mm2
R:Mirror V:Silver B:Blue
Front Panel('*' Position)
Type
Model

ART COOL Mirror

ART COOL Mirror


ARNU15GSE*2
ARNU18GS8*2
4.5
5.6
3,900
4,800
Cooling Capacity
15,400
19,100
5.0
6.3
4,300
5,400
Heating Capacity
17,100
21,500
915x169x282
1,107x200x299
Dimensions(WxDxH) Body
36.0x6.5x11.1
43.9x7.9x11.8
2x15x18
2x15x20
Rows
x
Columns
x
FPI
Coil
0.21
0.26
Face Area
m2
Cross Flow Fan
Cross Flow Fan
Type
20
20
Motor Output x Number
W
0.20
0.20
Running Current
A
10.5/8/6
14.4/13/11
Fan
Air Flow Rate(H/M/L)
CMM
371/283/212
508/459/388
cfm
Direct
Direct
Drive
BLDC
BLDC
Motor type
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Temperature Control
Foamed polystrene
Foamed polystrene
Sound Absorbing Thermal Insulation Material
Resin Net(washable)
Resin Net(washable)
Air Filter
Fuse
Fuse
Safety Device
6.35(1/4)
6.35(1/4)
Liquid Side
mm(inch)
12.7(1/2)
12.7(1/2)
Pipe Connections Gas Side
mm(inch)
16
16
Drain Pipe(Internal Dia.)
mm
11.2(24.7)
15(33.1)
Net Weight
kg(lbs)
42/36/27
37/34/31
Noise Level(Sound Press, 1m, H/M/L)
dB(A)3
1, 220 ~240, 50
1, 220 ~ 240, 50
Power Supply
, V, Hz
1, 220, 60
1, 220, 60
EEV
EEV
Refrigerant Control
CV1.5 x 3C
CV1.5 x 3C
Power cable
mm2
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
Transmission cable
mm2
R:Mirror V:Silver B:Blue
Front Panel('*' Position)
Type
Model

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h
mm
inch

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve

8-3

Indoor unit

ARNU24GS8*2
7.1
6,100
24,200
8.0
6,900
27,300
1,107x200x299
43.9x7.9x11.8
2x15x20
0.26
Cross Flow Fan
20
0.20
17.9/14.4/12
632/508/424
Direct
BLDC
Microprocessor, Thermostat for cooling and heating
Foamed polystrene
Resin Net(washable)
Fuse
9.52(3/8)
15.88(5/8)
16
15(33.1)
43/37/32
1, 220 ~ 240, 50
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.25 x 2C

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

ART COOL Mirror

Tighten the flare nut with a wrench.

Wall Mounted

Spanner (fixed)
Flare nut
Connection
pipe

Torque
wrench

Wrap the area which accommodates the rear piping housing section with vinyl tape.
Indoor
unit pipe
Wrap with vinyl tape

Connection
pipe
Vinyl tape
(wide)

Connecting cable

Indoor
unit tubing

Pipe

When extending the drain hose at the indoor unit,


install the drain pipe.

Drain pipe

Vinyl tape(narrow)

Bundle the piping and drain hose together by


wrapping them with vinyl tape over the range within which they fit into the rear piping housing section.
Wrap with vinyl tape

Indoor unit
drain hose
Vinyl tape(narrow)

Pipe

Adhesive

Vinyl tape(wide)
Drain hose

6. Wrap the insulation material around the connecting portion.


Overlap the connection pipe insulation material
and the indoor unit pipe insulation material. Bind
them together with vinyl tape so that there is no
gap.

Plastic bands

For right rear piping


1. Route the indoor tubing and the drain hose to the
required piping hole position.

Insulation material

2. Insert the piping, drain hose and the connecting


cable into the piping hole.
Connecting
cable

Drain pipe

7-19

Indoor unit

Wall Mounted

3. Insert the connecting cable into the indoor unit.


Don't connect the cable to the indoor unit.
Make a small loop with the cable for easy connection later.

When extending the drain hose at the indoor unit,


install the drain pipe.

Drain hose

4. Tape the drain hose and the connecting cable.


Connecting cable
Indoor unit drain hose

7. Wrap the insulation material around the connecting portion.


Overlap the connecting pipe heat insulation and the
indoor unit pipe heat insulation material. Bind them
together with vinyl tape so that there is no gap.
5. Indoor unit installation
Hang the indoor unit from the hooks at the top of
the installation plate.
Insert the spacer etc. between the indoor unit and
the installation plate and separate the bottom of the
indoor unit from the wall.

Plastic bands

Insulation material

Wrap the area which accommodates the rear piping


housing section with vinyl tape.

Indoor unit
Spacer

Connection
pipe

Installation plate

Vinyl tape
(wide)

8cm

6. Connecting the pipings to the indoor unit and the


drain hose to drain pipe.
Align the center of the pipings and sufficiently tighten the flare nut by hand.

Indoor unit tubing

Flare nut

Indoor
unit piping
Wrap with vinyl tape
Pipe

Connecting
cable

Vinyl tape
(narrow)

Pipings

Tighten the flare nut with a wrench.


Spanner (fixed)

Torque
wrench

Flare nut
Connection
pipe

Indoor
unit tubing

Wall Mounted

Indoor unit

7-20

Wall Mounted

Vinyl tape(narrow)
Adhesive

Wall Mounted

Bundle the piping and drain hose together by wrapping them with cloth tape over the range within
which they fit into the rear piping housing section.

10. Indoor unit installation


Remove the spacer.
Ensure that the hooks are properly seated on the
installation plate by moving it left and right.

Pipe
Drain hose

Vinyl tape
(narrow)

Connecting
cable

Wrap with
vinyl tape(wide)

8. Reroute the pipings and the drain hose across the


back of the chassis.

Drain hose

Press the lower left and right sides of the unit against
the installation plate until the hooks engage into their
slots(clicking sound).

Piping for
passage through
piping hole

9. Set the pipings and the drain hose to the back of


the chassis with the tubing holder.
Hook the edge of tubing holder to tap on chassis
and push the bottom of tubing holder to be
engaged at the bottom of chassis.

Tubing holder
1 Hook

2 Push

7-21

Indoor unit

Wall Mounted

10.2 Connection of Pipings


2. To check the drainage.
Pour a glass of water on the evaporator.
Ensure the water flows through the drain hose of the
indoor unit without any leakage and goes out the
drain exit.
Wall Mounted

1. To remove the front panel from the indoor unit,


remove the front panel from the indoor unit
cabinet.
Set the air direction louvers up-and-down to the
position(horizontally) by hand.
Remove the securing screws that retain the front
panel. Pull the lower left and right sides of the grille
toward you and lift it off.
(2.1/7, 2.6/9, 3.5/12 kW/Btu models: 2EA,
3.5/18 kW/Btu models: 3EA)

Pull the right and


the left side.

Screw

10.3 Connect the cable to the


indoor unit
1. Connect the wires to the terminals on the
control board individually according to the
outdoor unit connection.
Ensure that the color of the wires of outdoor
unit and the terminal No. are the same as those
of indoor unit respectively.

Remote control
co
cord

Connecting cable

Wall Mounted

Indoor unit

7-22

Terminal Block Indoor

Wall Mounted

1(L)

2(N)

SODU

INTERNET DRY1 DRY2 GND 12V

IDU
-

Outdoor
Unit

INDOOR POWER INPUT

2. Attach the Grille onto the cabinet.


Grasp lower the left and right side of the Grille
and engage four tabs on the top inside edge of
the chassis.
Press the Grille toward the chassis until it is
back in place.

CAUTION
After the confirmation of the above conditions, prepare the wiring as follows:
1) As for the method of wiring, follow the circuit diagram posted on the inside of control cover.
2) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from
vibrations to which the unit is subjected during the course of transportation. Check them and
make sure that they are all tightly fastened. (If they are loose, it could cause burn-out of the
wires.)
3) Confirm the specification of power source.
4) Confirm that electrical capacity is sufficient.
5) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked
on the name plate.
6) Confirm that the cable thickness is as specified in the power source specification.
(Particularly note the relation between the cable length and thickness.)
7) In a wet or moist area, always install an earth leakage circuit breaker.
8) The following would be caused by voltage drop.
Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the
normal function of the overload.
9) The means for disconnection from a power supply shall be incorporated in the fixed wiring and
have an air gap contact separation of at least 3mm in each active(phase) conductor.

7-23

Indoor unit

Wall Mounted

WIRED REMOTE CONTROLLER INSTALLATION


Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place away
from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.

Do not install the remote controller where it can be affected by:

TEMP

Wall Mounted

- Drafts, or dead spots behind doors and in corners.


- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)

yes

Remote Controller

no

TEMP

Controller
Remote

TEMP

Remote Controller

5feet
(1.5meters)

no

no

Fig.1 Typical locations for remote controller

Wall Mounted

Indoor unit

7-24

11. Accessories

Wall Mounted

Standard Accessories
Name

Installation panel

Type "A" screw

Quantity

1 set

SE: 6 EA
S5: 8 EA

(Other)
Owner's manual
Installation manual

SE

Shape
S5

CAUTION
Use only those accessories (Standard or optional) which have designated specifications.

7-25

Indoor unit

Wall Mounted

1. List of functions
2. Specifications
3. Dimensions
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. Air Velocity and Temperature Distribution
8. Electric Characteristics
9. Sound Levels
10. Installation
11. Accessories

ART COOL Mirror

Indoor unit

ART COOL Mirror

ART COOL Mirror

ART COOL Mirror

1. List of functions
Category

Air flow

Air purifying

Installation

Reliability

Convenience

Individual
control

Special
function kit

Function
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Wide wired remote controller
Deluxe wired remote controller
Simple wired remote controller
Wired remote controller(for hotel use)
Wireless LCD remote control
Zone control
CTIE
Electro thermostat

ARNU07GSE*2, ARNU09GSE*2, ARNU12GSE*2


ARNU15GSE*2, ARNU18GS8*2, ARNU24GS8*2
1
Auto
Auto
Auto
X
3/4/3
O
O
O
X
Option
O
O
O
O
O(Heat recovery)
O
O(Heat pump or Cooling only)
O
O
O
O
O
O
O
O
Accessory
Accessory
Accessory
Accessory
Accessory
-

O : Applied
X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

8-1

Indoor unit

ART COOL Mirror

2. Specifications
Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h
mm
inch

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve

ART COOL Mirror

Indoor unit

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

8-2

ART COOL Mirror

ART COOL Mirror


ARNU07GSE*2
ARNU09GSE*2
ARNU12GSE*2
2.2
2.8
3.6
1,900
2,400
3,100
Cooling Capacity
7,500
9,600
12,300
2.5
3.2
4.0
2,200
2,800
3,400
Heating Capacity
8,500
10,900
13,600
915x169x282
915x169x282
915x169x282
Dimensions(WxDxH) Body
36.0x6.5x11.1
36.0x6.5x11.1
36.0x6.5x11.1
2x15x18
2x15x18
2x15x18
Rows
x
Columns
x
FPI
Coil
0.21
0.21
0.21
Face Area
m2
Cross Flow Fan
Cross Flow Fan
Cross Flow Fan
Type
20
20
20
Motor Output x Number
W
0.20
0.20
0.20
Running Current
A
7/6/4
8/7/5
10/8/6
Fan
Air Flow Rate(H/M/L)
CMM
247/212/141
282/247/177
353/283/212
cfm
Direct
Direct
Direct
Drive
BLDC
BLDC
BLDC
Motor type
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Temperature Control
Foamed polystrene
Foamed polystrene
Foamed polystrene
Sound Absorbing Thermal Insulation Material
Resin Net(washable)
Resin Net(washable)
Resin Net(washable)
Air Filter
Fuse
Fuse
Fuse
Safety Device
6.35(1/4)
6.35(1/4)
6.35(1/4)
Liquid Side
mm(inch)
12.7(1/2)
12.7(1/2)
12.7(1/2)
Pipe Connections Gas Side
mm(inch)
16
16
16
Drain Pipe(Internal Dia.)
mm
11.2(24.7)
11.2(24.7)
11.2(24.7)
Net Weight
kg(lbs)
37/33/23
39/35/25
41/36/27
Noise Level(Sound Press, 1m, H/M/L)
dB(A)3
1, 220 ~ 240, 50
1, 220 ~240, 50
1, 220 ~240, 50
Power Supply
, V, Hz
1, 220, 60
1, 220, 60
1, 220, 60
EEV
EEV
EEV
Refrigerant Control
CV1.5 x 3C
CV1.5 x 3C
CV1.5 x 3C
Power cable
mm2
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
Transmission cable
mm2
R:Mirror V:Silver B:Blue
Front Panel('*' Position)
Type
Model

ART COOL Mirror

ART COOL Mirror


ARNU15GSE*2
ARNU18GS8*2
4.5
5.6
3,900
4,800
Cooling Capacity
15,400
19,100
5.0
6.3
4,300
5,400
Heating Capacity
17,100
21,500
915x169x282
1,107x200x299
Dimensions(WxDxH) Body
36.0x6.5x11.1
43.9x7.9x11.8
2x15x18
2x15x20
Rows
x
Columns
x
FPI
Coil
0.21
0.26
Face Area
m2
Cross Flow Fan
Cross Flow Fan
Type
20
20
Motor Output x Number
W
0.20
0.20
Running Current
A
10.5/8/6
14.4/13/11
Fan
Air Flow Rate(H/M/L)
CMM
371/283/212
508/459/388
cfm
Direct
Direct
Drive
BLDC
BLDC
Motor type
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Temperature Control
Foamed polystrene
Foamed polystrene
Sound Absorbing Thermal Insulation Material
Resin Net(washable)
Resin Net(washable)
Air Filter
Fuse
Fuse
Safety Device
6.35(1/4)
6.35(1/4)
Liquid Side
mm(inch)
12.7(1/2)
12.7(1/2)
Pipe Connections Gas Side
mm(inch)
16
16
Drain Pipe(Internal Dia.)
mm
11.2(24.7)
15(33.1)
Net Weight
kg(lbs)
42/36/27
37/34/31
Noise Level(Sound Press, 1m, H/M/L)
dB(A)3
1, 220 ~240, 50
1, 220 ~ 240, 50
Power Supply
, V, Hz
1, 220, 60
1, 220, 60
EEV
EEV
Refrigerant Control
CV1.5 x 3C
CV1.5 x 3C
Power cable
mm2
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
Transmission cable
mm2
R:Mirror V:Silver B:Blue
Front Panel('*' Position)
Type
Model

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h
mm
inch

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve

8-3

Indoor unit

ARNU24GS8*2
7.1
6,100
24,200
8.0
6,900
27,300
1,107x200x299
43.9x7.9x11.8
2x15x20
0.26
Cross Flow Fan
20
0.20
17.9/14.4/12
632/508/424
Direct
BLDC
Microprocessor, Thermostat for cooling and heating
Foamed polystrene
Resin Net(washable)
Fuse
9.52(3/8)
15.88(5/8)
16
15(33.1)
43/37/32
1, 220 ~ 240, 50
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.25 x 2C

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

ART COOL Mirror

Indoor unit
567

915

165

282

169

51

282

Air suction grill

Air discharge grill

Name

915

282

Descripition

(unit : mm)

169

(unit : mm)

CHASSIS CODE: SE

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Note

Number

ARNU07GSE*2
ARNU09GSE*2
ARNU12GSE*2
ARNU15GSE*2

Model

ARNU07GSE*2
ARNU09GSE*2
ARNU12GSE*2
ARNU15GSE*2

ART COOL Mirror

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

53

ART COOL Mirror


ART COOL Mirror

3. Dimensions

8-4

265

804

1107

72
58 122

281

93

200

53

10
63

8-5

Indoor unit

ART COOL Mirror

48

299

Air suction grille

Installation plate

Remark

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

CHASSIS CODE: S8

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Note

Knockout hole

Display & signal receiver

3
4

Front panel

Part Name

No.

ARNU18GS8*2
ARNU24GS8*2

ART COOL Mirror

ART COOL Mirror

4. Piping Diagrams

Heat Exchanger

:Cooling
:Heating

EEV
Filter
Th2

Th3

C.F.F

ART COOL Mirror

Filter

lndoor unit

Th1

Refrigerant pipe connection port diameter


[Unit: mm(inch)]

MODEL

GAS

LIQUID

ARNU07GSE*2

12.7(1/2)

6.35(1/4)

ARNU09GSE*2

12.7(1/2)

6.35(1/4)

ARNU12GSE*2

12.7(1/2)

6.35(1/4)

ARNU15GSE*2

12.7(1/2)

6.35(1/4)

ARNU18GS8*2

12.7(1/2)

6.35(1/4)

ARNU24GS8*2

15.88(5/8)

9.52(3/8)

*Panel Color (SE/S8 chassis) : R(Mirror),V(Silver), B(Blue)

LOC.

Description

Th1

Room thermistor

Th2

Pipe in thermistor

Th3

Pipe out thermistor

ART COOL Mirror

PCB Connector

Indoor unit

CN-TH1
CN-TH2

8-6

5. Wiring Diagrams
ART COOL Mirror

SE/S8 Chassis

CONNECTOR NUMBER

LOCATION POINT

FUNCTION

CN-MOTOR1

Fan motor output

Motor output of BLDC

CN-COM

Communication

Communication between indoor and outdoor

CN-EEV

EEV output

EEV control output

CN-L/R

Step motor

Step motor output for left/right

CN-U/D

Step motor

Step motor output

CN-TH1

Room/pipe sensor

Room & pipe thermistor

CN-TH2

Discharge pipe sensor

Discharge pipe thermistor

CN-SUC

Step motor(front)

Front panel step motor

CN-HVB

Air purifier

Air purifier output

CN-VFD

Display

Display of indoor status

CN-12V

Safety connection

Safety of indoor status

CN-REMO

Remote controller

Remote control line

CN-CC

Dry contact

Dry contact line

CN-HVB

Air clean

Air clean control

8-7

Indoor unit

ART COOL Mirror

6. Capacity Tables
6.1 Cooling Capacity

Cooling Capacity

23
16
TC SHC
kW kW

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

30
22
TC SHC
kW
kW

Capacity
Index

2.2

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8

1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6

2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.2

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.5

2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.5
2.5
2.5
2.4
2.4
2.3
2.3

1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.6
1.6
1.6
1.5
1.5
1.5
1.5

2.9
2.9
2.8
2.8
2.7
2.7
2.7
2.6
2.6
2.6
2.5
2.5
2.5
2.4
2.4
2.3

1.7
1.6
1.6
1.6
1.6
1.6
1.5
1.5
1.5
1.5
1.5
1.4
1.4
1.4
1.4
1.4

2.8

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6

2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8

2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
2.9
2.9

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.3
3.2
3.2
3.1
3.1
3.0
3.0
2.9

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.0
2.0
2.0
1.9
1.9
1.9

3.7
3.6
3.6
3.5
3.5
3.4
3.4
3.4
3.3
3.3
3.2
3.2
3.1
3.1
3.0
3.0

2.1
2.1
2.1
2.0
2.0
2.0
2.0
1.9
1.9
1.9
1.9
1.8
1.8
1.8
1.8
1.7

3.6

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1

2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9

2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6

3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6

2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6

3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.7
3.7

2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.6
2.6

4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.2
4.1
4.1
4.0
4.0
3.9
3.8
3.7

2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.7
2.7
2.6
2.6
2.5
2.5
2.4

4.7
4.7
4.6
4.6
4.5
4.4
4.4
4.3
4.3
4.2
4.2
4.1
4.0
4.0
3.9
3.8

2.8
2.7
2.7
2.7
2.6
2.6
2.6
2.5
2.5
2.5
2.4
2.4
2.4
2.3
2.3
2.2

Notes:
TC: Total Capacity(kW)

ART COOL Mirror

32
24
TC SHC
kW kW

SHC: Sensible Heat Capacity(kW)

Indoor unit

8-8

ART COOL Mirror

20
14
TC SHC
kW kW

Outdoor
air temp.
(DB, C)

ART COOL Mirror

Cooling Capacity

20
14
TC SHC
kW kW

23
16
TC SHC
kW kW

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

30
22
TC SHC
kW
kW

Capacity
Index

Outdoor
air temp.
(DB, C)

4.5

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0

2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7

3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6

2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9

4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2

3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2

4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5

3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2

4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8

3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3

5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4

3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5

5.9
5.8
5.8
5.7
5.6
5.5
5.5
5.4
5.3
5.3
5.2
5.1
5.0
5.0
4.9
4.8

3.5
3.4
3.4
3.3
3.3
3.2
3.2
3.2
3.1
3.1
3.0
3.0
2.9
2.9
2.9
2.8

5.6

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8

3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3

4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5

3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7

5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2

4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0

5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6

4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0

6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
5.8
5.7

4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.1
4.0

6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.6
6.4
6.4
6.3
6.2
6.0
5.9
5.8

4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.2
4.1
4.1
4.0
3.9
3.8
3.8

7.4
7.3
7.2
7.1
7.0
6.9
6.8
6.7
6.6
6.6
6.5
6.4
6.3
6.2
6.1
6.0

4.3
4.2
4.2
4.1
4.1
4.0
4.0
3.9
3.9
3.8
3.8
3.7
3.7
3.6
3.6
3.5

7.1

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8

4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3

5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7

4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7

6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6

5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1

7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1

5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2

7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.4
7.2

5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.2
5.1

8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.4
8.2
8.1
8.0
7.8
7.7
7.5
7.4

5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.5
5.4
5.3
5.2
5.1
5.0
4.9
4.8

9.3
9.2
9.1
9.0
8.8
8.7
8.7
8.5
8.4
8.3
8.2
8.1
7.9
7.8
7.7
7.6

5.5
5.5
5.4
5.3
5.2
5.2
5.1
5.1
5.0
4.9
4.8
4.8
4.7
4.6
4.6
4.5

Notes:
TC: Total Capacity(kW)

8-9

32
24
TC SHC
kW kW

SHC: Sensible Heat Capacity(kW)

Indoor unit

ART COOL Mirror

6.2 Heating Capacity


Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

Heating Capacity
Indoor air temp. (DB, C)

16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

kW

kW

kW

kW

kW

2.2

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.3
2.4
2.5
2.6
2.8
2.8
2.9
2.9
2.9
2.9
2.9

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.3
2.4
2.5
2.6
2.7
2.7
2.7
2.7
2.7
2.7
2.7

1.7
1.7
1.8
1.7
1.8
1.9
1.9
2.0
2.0
2.1
2.2
2.3
2.4
2.5
2.5
2.5
2.5
2.5
2.5

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.2
2.3
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.2
2.3
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

1.7
1.7
1.8
1.9
2.0
2.1
2.1
2.1
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

2.8

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

2.1
2.2
2.3
2.5
2.6
2.7
2.8
2.8
2.9
3.0
3.2
3.4
3.6
3.6
3.7
3.7
3.7
3.7
3.7

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.9
3.0
3.2
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

2.1
2.2
2.3
2.2
2.3
2.4
2.5
2.5
2.6
2.7
2.8
3.0
3.1
3.2
3.2
3.2
3.2
3.2
3.2

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.8
3.0
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.8
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0

2.1
2.2
2.3
2.4
2.6
2.7
2.7
2.7
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8

3.6

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

2.7
2.8
2.9
3.1
3.2
3.4
3.4
3.5
3.6
3.8
4.0
4.2
4.4
4.5
4.6
4.6
4.6
4.6
4.6

2.7
2.8
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.8
4.0
4.2
4.3
4.3
4.3
4.3
4.3
4.3
4.3

2.7
2.8
2.9
2.7
2.9
3.0
3.1
3.2
3.3
3.4
3.5
3.7
3.9
4.0
4.0
4.0
4.0
4.0
4.0

2.6
2.8
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.7
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9

2.6
2.7
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.7
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8

2.6
2.7
2.9
3.0
3.2
3.4
3.4
3.4
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5

ART COOL Mirror

kW
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

Notes: TC: Total Capacity(kW)

ART COOL Mirror

Indoor unit

8-10

ART COOL Mirror

Heating Capacity
Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

Indoor air temp. (DB, C)


16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

kW

kW

kW

kW

kW

kW

4.5

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

3.4
3.5
3.7
3.9
4.1
4.3
4.3
4.4
4.6
4.8
5.0
5.3
5.6
5.6
5.8
5.8
5.8
5.8
5.8

3.4
3.5
3.7
3.8
4.1
4.3
4.3
4.4
4.6
4.8
5.0
5.3
5.4
5.4
5.4
5.4
5.4
5.4
5.4

3.4
3.5
3.7
3.4
3.6
3.8
3.9
4.0
4.1
4.3
4.4
4.6
4.9
5.0
5.0
5.0
5.0
5.0
5.0

3.3
3.5
3.7
3.8
4.0
4.3
4.3
4.4
4.4
4.6
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8

3.3
3.4
3.7
3.8
4.0
4.2
4.3
4.4
4.4
4.6
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7

3.3
3.4
3.6
3.8
4.0
4.2
4.3
4.3
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4

5.6

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

4.2
4.3
4.6
4.9
5.1
5.4
5.4
5.5
5.7
6.0
6.2
6.6
7.0
7.1
7.2
7.2
7.2
7.2
7.2

4.2
4.3
4.6
4.8
5.1
5.4
5.4
5.5
5.7
6.0
6.2
6.6
6.7
6.7
6.7
6.7
6.7
6.7
6.7

4.2
4.3
4.6
4.3
4.5
4.8
4.9
5.0
5.1
5.4
5.5
5.8
6.2
6.3
6.3
6.3
6.3
6.3
6.3

4.2
4.3
4.6
4.8
5.0
5.4
5.4
5.5
5.6
5.8
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1

4.2
4.3
4.6
4.8
5.0
5.3
5.4
5.5
5.6
5.8
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9

4.2
4.3
4.5
4.8
5.0
5.3
5.4
5.4
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

7.1

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

5.4
5.5
5.8
6.2
6.5
6.8
6.9
7.0
7.3
7.6
7.9
8.4
8.9
9.0
9.2
9.2
9.2
9.2
9.2

5.4
5.5
5.8
6.1
6.5
6.8
6.9
7.0
7.3
7.6
7.9
8.4
8.6
8.6
8.6
8.6
8.6
8.6
8.6

5.4
5.5
5.8
5.5
5.8
6.0
6.2
6.3
6.5
6.8
7.0
7.4
7.8
8.0
8.0
8.0
8.0
8.0
8.0

5.3
5.5
5.8
6.1
6.4
6.8
6.9
7.0
7.1
7.4
7.7
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8

5.3
5.4
5.8
6.1
6.4
6.7
6.9
7.0
7.1
7.4
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5

5.3
5.4
5.8
6.1
6.4
6.7
6.8
6.8
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0

Notes: TC: Total Capacity(kW)

8-11

Indoor unit

ART COOL Mirror

7. Air Velocity and Temperature Distribution


ARNU07GSE*2
Cooling

Heating

Discharge angle:45

Discharge angle:60
Air velocity [m/s]

Air velocity [m/s]

2.7m

2m

2m

2.0

2.0

1.5

1m

1m
1.5
1.0

0.5

0.5

5m

4m

3m

2m

0m
0m

1m

5m

4m

1.0

3m

2m

0m
0m

1m

Temperature [C]

Temperature [C]

2.7m

2.7m

2m

2m
33

18
30
20

1m

1m
24

22

21

24

5m

4m

3m

2m

1m

0m
0m

5m

4m

27

3m

2m

0m
0m

1m

ARNU12GSE*2
Cooling

Heating

Discharge angle:45

Discharge angle:60
Air velocity [m/s]

Air velocity [m/s]


2.7m

2.7m

2m

2m
2.0

2.0
1.5

1m

1.5

0.5
0.5

5m

4m

3m

1m

1.0

1.0

2m

1m

0m
0m

5m

4m

3m

2m

0m
0m

1m

Temperature [C]

Temperature [C]
2.7m

2.7m

2m

2m
33

18

30

1m

21

1m
20
24

5m

4m

3m

ART COOL Mirror

24

27

22

2m

1m

0m
0m

5m

Indoor unit

4m

3m

2m

1m

0m
0m

8-12

ART COOL Mirror

2.7m

8. Electric Characteristics
Units
ART COOL Mirror

Model

Type

Power Supply
Hz

Volts

Voltage Range MCA

IFM

Input(W)

MFA

kW

FLA

Cooling Heating

ARNU07GSE*2

SE

1.29

15

0.02

0.23

40

40

ARNU09GSE*2

SE

1.29

15

0.02

0.23

40

40

ARNU12GSE*2

SE

Max:264

1.29

15

0.02

0.23

40

40

ARNU15GSE*2

SE

Min:198

1.29

15

0.02

0.23

40

40

ARNU18GS8*2

S8

1.29

15

0.02

0.23

35

35

ARNU24GS8*2

S8

1.29

15

0.02

0.23

35

35

ARNU07GSE*2

SE

1.29

15

0.02

0.23

40

40

ARNU09GSE*2

SE

ARNU12GSE*2

SE

ARNU15GSE*2

SE

ARNU18GS8*2
ARNU24GS8*2

50

220 ~ 240

1.29

15

0.02

0.23

40

40

Max:242

1.29

15

0.02

0.23

40

40

Min:198

1.29

15

0.02

0.23

40

40

S8

1.29

15

0.02

0.23

35

35

S8

1.29

15

0.02

0.23

35

35

60

220

Symbols:
MCA : Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
IFM : Indoor Fan Motor
Note :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA + 1
MFA 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the MCA.

8-13

Indoor unit

ART COOL Mirror

9. Sound Levels
Overall
Notes:
- Data is valid at nominal operating condition
- Reference accoustic pressure OdB = 20Pa
- Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment is installed.

1m
1m

ART COOL Mirror

Microphone
Sound Levels dB(A)

Model

H
37
39
41
42
37
43

ARNU07GSE*2
ARNU09GSE*2
ARNU12GSE*2
ARNU15GSE*2
ARNU18GS8*2
ARNU24GS8*2

M
33
35
36
36
34
37

L
23
25
27
27
31
32

Sound Pressure Level


ARNU07GSE*2

80

NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30

63

NC-65

60

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
NC-25

20

NC-25
Approximate
Hearing
Threshold

70

NC-20

NC-15
125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)

10

Octave Band Sound Pressure Level (dB re 20Pa )

NC-60

Octave Band Sound Pressure Level (dB re 20Pa )

Approximate
Hearing
Threshold
63

NC-60

NC-50

NC-40

NC-30

10

ARNU24GS8*2
70

NC-60
NC-55
NC-50
NC-45
NC-40
NC-35

Octave Band Sound Pressure Level (dB re 20Pa )

70

NC-65

NC-65

60

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
20

10

NC-25
Approximate
Hearing
Threshold
63

NC-20

NC-15
125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)

ART COOL Mirror

NC-65

60

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30

NC-30
20

10

NC-25
Approximate
Hearing
Threshold
63

NC-20

NC-15
125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)

ARNU18GS8*2

70

30

NC-25
Approximate
Hearing
Threshold
63

80

40

NC-35

30

80

50

NC-45

40

80

60

NC-55

50

20

NC-15
125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)

ARNU15GSE*2

NC-65

60

NC-20

Octave Band Sound Pressure Level (dB re 20Pa )

Octave Band Sound Pressure Level (dB re 20Pa )

NC-65

60

20

Octave Band Sound Pressure Level (dB re 20Pa )

ARNU12GSE*2
80

70

70

10

ARNU09GSE*2

80

NC-20

NC-15
125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)

Indoor unit

NC-25

20

10

Approximate
Hearing
Threshold
63

NC-20

NC-15
125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)

8-14

ART COOL Mirror

10. Installation
Please read this instruction sheet completely before installing the product.
When the power cord is damaged, replacement work shall be performed by authorized personnel only.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Installation Parts Provided

1. Type "A" screw

2. Installation Plate

Required Parts

Required Tools

Installation plate
Four type "A" screws
Connecting cable

Level gauge
Screw driver
Electric drill
Hole core drill

Pipes: Gas side


Liquid side
Insulation materials
Additional drain pipe

Flaring tool set


Specified torque wrenches
Spanner......................................................Half union
A glass of water
Screw driver
Thermometer

8-15

Indoor unit

ART COOL Mirror

10.1 Selection of the best location

More than 100mm

More than 200mm

There should not be any heat source or steam near the

More than 100mm


More than 2300mm

ART COOL Mirror

unit.
There should not be any obstacles to prevent the air circulation.
A place where air circulation in the room will be good.
A place where drainage can be easily obtained.
A place where noise prevention is taken into consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the wall, ceiling, fence, or other obstacles.

S8 chassis
Installation Plate

Chassis
Hook

The mounting wall should be strong and solid enough to


protect it from the vibration.
Mount the installation plate on the wall with four Type
"A" screws.
(If mounting the unit on the concrete wall, consider using
anchor bolts.)
Always mount the Installation plate horizontally by
aligning the marking-off line by means of the thread
and a level.

Type A

SE chassis
Installation Plate

Chassis
Hook

Type A

The lower left and the right side of Installation Plate

S8 chassis

Installation plate
133mm

100mm

Installation plate

110mm

70mm

70mm

70mm

70mm

85mm

Left rear piping

Right rear piping

110mm

SE chassis

Left rear piping

65mm

Right rear piping

CAUTION : In case that the unit is installed near the sea, the installation parts
may be corroded by salt. The installation parts (and the unit) should be taken
appropriate anti-corrosion measures.

ART COOL Mirror

Indoor unit

8-16

ART COOL Mirror

Preparing work for installation


Preparing the indoor unit's piping and drain hose for
installation through the wall.
Remove the plastic tubing retainer(see illustration
below) and pull the tubing and drain hose away from
chassis.
Replace the plastic tubing holder in the original position.

3. Tape the tubing, drain hose and the connecting


cable. Be sure that the drain hose is located at the
lowest side of the bundle. Locating at the upper
side can cause drain pan to overflow inside the
unit.

Tape
Connecting
pipe
Drain hose

Connecting cable

NOTICE : If the drain hose is routed inside the room,


insulate the hose with an insulation material* so that dripping from "sweating"(condensation) will not damage furniture or floors.

For right rear piping

*Foamed polyethylene or equivalent is recommended.

1. Route the indoor tubing and the drain hose in the


direction of rear left.

4. Indoor unit installation


Hook the indoor unit onto the upper portion of the
installation plate.(Engage the two hooks of the rear
top of the indoor unit with the upper edge of the
installation plate.) Ensure that the hooks are properly
seated on the installation plate by moving it left and
right.

Drain hose

Connecting
cable

Drain hose

2. Insert the connecting cable into the indoor unit


from the outdoor unit through the piping hole.
Do not connect the cable to the indoor unit.
Make a small loop with the cable for easy connection
later.

8-17

Press the lower left and right sides of the unit against
the installation plate until the hooks engage into their
slots(clicking sound).

Indoor unit

ART COOL Mirror

5. Connecting the pipings to the indoor unit and drain


hose to drain pipe.
Align the center of the pipings and sufficiently tighten
the flare nut by hand.

Wrap the area which accommodates the rear piping housing section with vinyl tape.
Indoor
unit pipe
Wrap with vinyl tape

Connection
pipe
Vinyl tape
(wide)

Connecting cable

Flare nut

Pipings

Pipe
Vinyl tape(narrow)

Tighten the flare nut with a wrench.


Spanner (fixed)
Flare nut
Connection
pipe

Torque
wrench

Bundle the piping and drain hose together by


wrapping them with vinyl tape over the range within which they fit into the rear piping housing section.
Wrap with vinyl tape
Pipe

Indoor
unit tubing

Mount the clamp on the boss with a type "B"


screw.(optional)

Type "B" screw

Drain hose

Clamp
Boss

Vinyl tape(wide)
Drain hose

For left rear piping


1. Route the indoor tubing and the drain hose to the
required piping hole position.

When extending the drain hose at the indoor


unit, install the drain pipe.

Drain pipe

Indoor unit
drain hose
Vinyl tape(narrow)
Adhesive

2. Insert the piping, drain hose and the connecting


cable into the piping hole.

6. Wrap the insulation material around the connecting portion.


Overlap the connection pipe insulation material
and the indoor unit pipe insulation material. Bind
them together with vinyl tape so that there is no
gap.
Plastic bands

ART COOL Mirror

Connecting cable
Drain pipe

Insulation material

Indoor unit

8-18

ART COOL Mirror

Indoor unit tubing

ART COOL Mirror

3. Insert the connecting cable into the indoor unit.


Don't connect the cable to the indoor unit.
Make a small loop with the cable for easy connection later.

When extending the drain hose at the indoor unit,


install the drain pipe.

Drain hose

4. Tape the drain hose and the connecting cable.


Connecting cable
Indoor unit drain hose
Vinyl tape(narrow)
Adhesive

5. Indoor unit installation


Hang the indoor unit from the hooks at the top of
the installation plate.
Insert the spacer etc. between the indoor unit and
the installation plate and separate the bottom of
the indoor unit from the wall.

Indoor unit
Spacer

Plastic bands

Insulation material

Wrap the area which accommodates the rear piping housing section with vinyl tape.
Connection
pipe

Installation plate
80mm

Vinyl tape
(wide)

6. Connecting the pipings to the indoor unit and


the drain hose to drain pipe.
Align the center of the pipings and sufficiently
tighten the flare nut by hand.

Indoor unit tubing

7. Wrap the insulation material around the connecting portion.


Overlap the connection pipe heat insulation and
the indoor unit pipe heat insulation material. Bind
them together with vinyl tape so that there is no
gap.

Flare nut

Indoor
unit piping
Wrap with vinyl tape
Pipe

Connecting
cable

Vinyl tape
(narrow)

Pipings

Tighten the flare nut with a wrench.

Spanner (fixed)

Torque
wrench

Flare nut
Connection
pipe

Indoor
unit tubing

8-19

Indoor unit

ART COOL Mirror

Bundle the piping and drain hose together by


wrapping them with cloth tape over the range
within which they fit into the rear piping housing
section.

9. Set the pipings and the drain hose to the back of


the chassis with the tubing holder.
Hook the edge of tubing holder to tap on chassis
and push the bottom of tubing holder to be
engaged at the bottom of chassis.

Pipe
Drain hose

Vinyl tape
(narrow)

8. Reroute the pipings and the drain hose across


the back of the chassis.

ART COOL Mirror

Wrap with
vinyl tape(wide)

Tubing holder

10. Indoor unit installation


Remove the spacer.
Ensure that the hooks are properly seated on the
installation plate by moving it left and right.

Connecting
cable

Drain hose

Piping for
passage through
piping hole

Press the lower left and right sides of the unit


against the installation plate until the hooks engage
into their slots(clicking sound).

ART COOL Mirror

Indoor unit

8-20

ART COOL Mirror

10.2 Connection of Pipings


1. To remove the front panel from the indoor unit,
remove the front panel from the indoor unit
cabinet.
Set the air direction louvers up-and-down to the
position(horizontally) by hand.
Remove the securing screws that retain the front
panel. Pull the lower left and right sides of the grille
toward you and lift it off.

2. To check the drainage.


Pour a glass of water on the evaporator.
Ensure the water flows through the drain hose of the indoor
unit without any leakage and goes out the drain exit.

Connecting area
drain hose

Leakage
checking
Drain pan

Drain
hose
Leakage
checking

Front panel

The drain hose should point downward for easy drain flow.
Downward slope

Do not make drain piping.


Accumulated
drain water
Air

Do not raise

Water
leakage

Water
leakage

Waving

Tip of drain hose


dipped in water
Water
leakage

Less than
50mm gap

Ditch

10.3 Connect the cable to the


indoor unit
1. Connect the wires to the terminals on the
control board individually according to the
outdoor unit connection.
Ensure that the color of the wires of outdoor
unit and the terminal No. are the same as
those of indoor unit respectively.

Remote control
co
cord

Connecting cable

8-21

Indoor unit

ART COOL Mirror

SODU

Terminal Block Indoor


1(L1) 2(L2)

IDU
-

INTERNET DRY1 DRY2 GND 12V Outdoor unit


B
A
-

INDOOR POWER INPUT

ART COOL Mirror

2. Attach the Grille onto the cabinet.


Grasp lower the left and right side of the Grille
and engage four tabs on the top inside edge of
the chassis.
Press the Grille toward the chassis until it is
back into its original place.

CAUTION
After the confirmation of the above conditions, prepare the wiring as follows:
1) As for the method of wiring, follow the circuit diagram posted on the inside of control cover.
2) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from
vibrations to which the unit is subjected during the course of transportation. Check them and
make sure that they are all tightly fastened. (If they are loose, it could cause burn-out of the
wires.)
3) Specification of power source.
4) Confirm that electrical capacity is sufficient.
5) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked
on the name plate.
6) Confirm that the cable thickness is as specified in the power source specification.
(Particularly note the relation between cable length and thickness.)
7) Always install an earth leakage circuit breaker in a wet or moist area.
8) The following would be caused by voltage drop.
Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the
normal function of the overload.
9) The means for disconnection from a power supply shall be incorporated in the fixed wiring and
have an air gap contact separation of at least 3mm in each active(phase) conductor.

ART COOL Mirror

Indoor unit

8-22

ART COOL Mirror

WIRED REMOTE CONTROLLER INSTALLATION


Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place away
from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.

Do not install the remote controller where it can be affected by:


- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)

TEMP

yes

Remote Controller

no

TEMP

Controller
Remote

TEMP

Remote Controller

5feet
(1.5meters)

no

no

Fig.1 Typical locations for remote controller

8-23

Indoor unit

ART COOL Mirror

11. Accessories
Standard Accessories
Name

Installation panel

Type "A" screws and


plastic anchors

Quantity

1 set

4 set

(Other)

SE

Shape

S8

CAUTION
Use only those accessories (Standard or optional) which have designated specifications.

ART COOL Mirror

Indoor unit

8-24

ART COOL Mirror

Owner's manual
Installation manual

ART COOL Gallery

ART COOL Gallery


ART COOL Panel
1. List of functions
2. Specifications
3. Dimensions
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. Electric Characteristics
8. Sound Levels
9. Installation
10. Accessories

Indoor unit

ART COOL Gallery

1. List of functions
Category

Air flow

Installation

Reliability

Convenience

Individual
control

Special
function kit

Air supply outlet


Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Wide wired remote controller
Deluxe wired remote controller
Simple wired remote controller
Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
Zone control
CTIE
Electro thermostat

ARNU07GSF*2, ARNU09GSF*2, ARNU12GSF*2


3
X
Auto
X
O
3/4/3
X
O
O
X
Option
O
O
O
O
O(Heat recovery)
O
O(Heat pump or Cooling only)
O
O
O
O
O
O
O
O
Accessory
Accessory
Accessory
Accessory
Accessory
Accessory
-

ART COOL Gallery

Air purifying

Function

O : Applied
X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

ART COOL Gallery

Indoor unit

9-1

ART COOL Gallery

2. Specifications

Type
Model
Cooling Capacity

Heating Capacity
Dimensions(WxDxH) Body
Coil

Fan

Rows x Columns x FPI


Face Area
Type
Motor Output x Number
Running Current
Air Flow Rate(H/M/L)

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h
mm
inch
m2
W
A
CMM
cfm

Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side
mm(inch)
Pipe Connections Gas Side
mm(inch)
Drain Pipe(Internal Dia.)
mm
Net Weight
kg(lbs)
Noise Level(Sound Press, 1m, H/M/L)
dB(A)3
Power Supply
Refrigerant Control
Power cable
Transmission cable
Front Panel('*' Position)

, V, Hz
mm2
mm2

ART COOL Gallery


ARNU07GSF*2
ARNU09GSF*2
ARNU12GSF*2
2.2
2.8
3.6
1,900
2,400
3,100
7,500
9,600
12,300
2.5
3.2
4.0
2,200
2,800
3,400
8,500
10,900
13,600
600x146x600
600x146x600
600x146x600
23.6x5.7x23.6
23.6x5.7x23.6
23.6x5.7x23.6
2x20x21
2x20x21
2x20x21
0.18
0.18
0.18
Turbo Fan
Turbo Fan
Turbo Fan
30
30
30
0.16
0.16
0.16
8.1/6.3/4.2
8.1/6.3/4.2
9.3/7.7/6.0
286/222/148
286/222/148
328/272/212
Direct
Direct
Direct
BLDC
BLDC
BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene
Foamed polystrene
Foamed polystrene
Resin Net(washable)
Resin Net(washable)
Resin Net(washable)
Fuse
Fuse
Fuse
6.35(1/4)
6.35(1/4)
6.35(1/4)
12.7(1/2)
12.7(1/2)
12.7(1/2)
12.2
12.2
12.2
15(33.1)
15(33.1)
15(33.1)
38/32/27
38/32/27
44/38/32
1, 220 ~ 240, 50
1, 220 ~ 240, 50
1, 220 ~ 240, 50
1, 220, 60
1, 220, 60
1, 220, 60
EEV
EEV
EEV
CV1.5 x 3C
CV1.5 x 3C
CV1.5 x 3C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
E:Red, V:Silver, G:Gold, 1: Kiss (Photo changeable)

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

Panel color: E(Red), V(Silver), G(Gold) Panel type


1: Kiss (Photo changeable) Gallery type

9-2

Indoor unit

ART COOL Gallery

ART COOL Gallery

Indoor unit

Fix Hole

500

Pipe Hole

Hanger Hole

Air discharge grill


Air suction grill

1
2

600

Descripition

(unit : mm)

146

(unit : mm)

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

CHASSIS CODE: SF

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Note

Name

600

Number

ARNU07GSF*2
ARNU09GSF*2
ARNU12GSF*2

Model

ARNU07GSF*2
ARNU09GSF*2
ARNU12GSF*2

ART COOL Gallery

ART COOL Gallery

3. Dimensions

9-3

525

ART COOL Gallery

4. Piping Diagrams

Heat Exchanger
Th3

EEV

:Cooling
:Heating

Filter

Th2

Turbo Fan

Filter

Th1

lndoor unit

Refrigerant pipe connection port diameter


[Unit: mm(inch)]

Model

Gas

Liquid

ARNU07GSF*2

12.7(1/2)

6.35(1/4)

ARNU09GSF*2

12.7(1/2)

6.35(1/4)

ARNU12GSF*2

12.7(1/2)

6.35(1/4)

*Panel color :E(Red), V(Silver), G(Gold), 1(Kiss (Photo changeable))

9-4

LOC.

Description

Th1

Room thermistor

Th2

Pipe in thermistor

Th3

Pipe out thermistor

PCB Connector
CN-TH1
CN-TH1

Indoor unit

ART COOL Gallery

5. Wiring Diagrams
SF Chassis

ART COOL Gallery

CONNECTOR NUMBER
CN-MOTOR1
CN-COM
CN-EEV
CN-D1
CN-LR1
CN-LR2
CN-UD
CN-TH1
CN-TH2
CN-REMO
CN-CC
CN-HVB

ART COOL Gallery

LOCATION POINT
Fan motor output
Communication
EEV output
Display
Step motor
Step motor
Step motor
Room/pipe sensor
Discharge pipe sensor
Remote controller
Dry contact
Air clean

FUNCTION
Motor output of BLDC
Communication between indoor and outdoor
EEV control output
Display of indoor status
Step motor output for left/right
Step motor output for left/right
Step motor output
Room and pipe thermistor
Discharge pipe thermistor
Remote control line
Dry contact line
Air clean control

Indoor unit

9-5

6. Capacity Tables
ART COOL Gallery

6.1 Cooling Capacity


Cooling Capacity

20
14
TC SHC
kW kW

23
16
TC SHC
kW kW

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

30
22
TC SHC
kW
kW

Capacity
Index

Outdoor
air temp.
(DB, C)

2.2

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8

1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6

2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.2

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.5

2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.5
2.5
2.5
2.4
2.4
2.3
2.3

1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.6
1.6
1.6
1.5
1.5
1.5
1.5

2.9
2.9
2.8
2.8
2.7
2.7
2.7
2.6
2.6
2.6
2.5
2.5
2.5
2.4
2.4
2.3

1.7
1.6
1.6
1.6
1.6
1.6
1.5
1.5
1.5
1.5
1.5
1.4
1.4
1.4
1.4
1.4

2.8

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6

2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8

2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
2.9
2.9

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.3
3.2
3.2
3.1
3.1
3.0
3.0
2.9

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.0
2.0
2.0
1.9
1.9
1.9

3.7
3.6
3.6
3.5
3.5
3.4
3.4
3.4
3.3
3.3
3.2
3.2
3.1
3.1
3.0
3.0

2.1
2.1
2.1
2.0
2.0
2.0
2.0
1.9
1.9
1.9
1.9
1.8
1.8
1.8
1.8
1.7

3.6

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1

2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9

2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6

3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6

2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6

3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.7
3.7

2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.6
2.6

4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.2
4.1
4.1
4.0
4.0
3.9
3.8
3.7

2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.7
2.7
2.6
2.6
2.5
2.5
2.4

4.7
4.7
4.6
4.6
4.5
4.4
4.4
4.3
4.3
4.2
4.2
4.1
4.0
4.0
3.9
3.8

2.8
2.7
2.7
2.7
2.6
2.6
2.6
2.5
2.5
2.5
2.4
2.4
2.4
2.3
2.3
2.2

Notes:
TC: Total Capacity(kW)

9-6

32
24
TC SHC
kW kW

SHC: Sensible Heat Capacity(kW)

Indoor unit

ART COOL Gallery

6.2 Heating Capacity


Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

Heating Capacity

Indoor air temp. (DB, C)


16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

kW

kW

kW

kW

kW

2.2

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.3
2.4
2.5
2.6
2.8
2.8
2.9
2.9
2.9
2.9
2.9

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.3
2.4
2.5
2.6
2.7
2.7
2.7
2.7
2.7
2.7
2.7

1.7
1.7
1.8
1.7
1.8
1.9
1.9
2.0
2.0
2.1
2.2
2.3
2.4
2.5
2.5
2.5
2.5
2.5
2.5

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.2
2.3
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.2
2.3
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

1.7
1.7
1.8
1.9
2.0
2.1
2.1
2.1
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

2.8

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

2.1
2.2
2.3
2.5
2.6
2.7
2.8
2.8
2.9
3.0
3.2
3.4
3.6
3.6
3.7
3.7
3.7
3.7
3.7

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.9
3.0
3.2
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

2.1
2.2
2.3
2.2
2.3
2.4
2.5
2.5
2.6
2.7
2.8
3.0
3.1
3.2
3.2
3.2
3.2
3.2
3.2

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.8
3.0
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.8
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0

2.1
2.2
2.3
2.4
2.6
2.7
2.7
2.7
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8

3.6

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

2.7
2.8
2.9
3.1
3.2
3.4
3.4
3.5
3.6
3.8
4.0
4.2
4.4
4.5
4.6
4.6
4.6
4.6
4.6

2.7
2.8
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.8
4.0
4.2
4.3
4.3
4.3
4.3
4.3
4.3
4.3

2.7
2.8
2.9
2.7
2.9
3.0
3.1
3.2
3.3
3.4
3.5
3.7
3.9
4.0
4.0
4.0
4.0
4.0
4.0

2.6
2.8
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.7
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9

2.6
2.7
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.7
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8

2.6
2.7
2.9
3.0
3.2
3.4
3.4
3.4
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5

ART COOL Gallery

kW
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

Notes:
TC: Total Capacity(kW)

ART COOL Gallery

Indoor unit

9-7

7. Electric Characteristics
ART COOL Gallery

Units
Model

Type

ARNU07GSF*2

SF

ARNU09GSF*2

SF

ARNU12GSF*2

SF

ARNU07GSF*2

SF

ARNU09GSF*2

SF

ARNU12GSF*2

SF

Power Supply
Hz
50

Volts
220 ~ 240

60

220

Voltage Range MCA


Max:264
Min:198

Max:242
Min:198

IFM

Input(W)

MFA

kW

FLA

Cooling Heating

1.23

15

0.024

0.18

35

35

1.23

15

0.024

0.18

35

35

1.23

15

0.024

0.18

35

35

1.23

15

0.024

0.18

35

35

1.23

15

0.024

0.18

35

35

1.23

15

0.024

0.18

35

35

Symbols:
MCA: Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
IFM : Indoor Fan Motor
Note :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA + 1
MFA 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the MCA.
5. Instead of fuse, use Circuit Breaker.

9-8

Indoor unit

ART COOL Gallery

8. Sound Levels
Overall
Notes:
- Data is valid at nominal operating condition
- Reference accoustic pressure OdB = 20Pa
- Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment is installed.

1m

ART COOL Gallery

0.8m
Microphone
Sound Levels dB(A)

Model

ARNU07GSF*2

38

32

27

ARNU09GSF*2

38

32

27

ARNU12GSF*2

44

38

32

Sound Pressure Level


ARNU07GSF*2
ARNU09GSF*2

ARNU12GSF*2
80

70

NC-65

60

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30

Octave Band Sound Pressure Level (dB re 20Pa )

Octave Band Sound Pressure Level (dB re 20Pa )

80

70

NC-65

60

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30

NC-25

20

NC-20

Approximate
Hearing
Threshold

NC-15

10
63

NC-25

20

Approximate
Hearing
Threshold
125

250

500

1000 2000 4000 8000

Octave Band Center Frequency (Hz)

ART COOL Gallery

NC-20
NC-15

10
63

125

250

500

1000 2000 4000 8000

Octave Band Center Frequency (Hz)

Indoor unit

9-9

ART COOL Gallery

9. Installation
Please read the instruction sheets completely before installing the product.
When the power cord is damaged, replacement work shall be performed by authorized personnel only.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Installation Parts Provided

1. Installation guide map

2. Type "A" screw and plastic anchors

Required Parts

Required Tools

Four type "A" screws


Connecting cable
Pipes: Gas side
Liquid side

Level gauge
Screw driver
Electric drill
Hole core drill
Flaring tool set
Specified torque wrenches
Spanner......................................................Half union
A glass of water
Screw driver
Thermometer

Insulation materials
Additional drain pipe

9.1 Selection of the best location


Do not have any heat or steam near the unit.
Select a place where there are no obstacles in front of the unit.
Make sure that condensation drainage can be conveniently
routed away.
Do not install near a doorway.
Ensure that the space around the left and right of the unit is
more than 500mm. The unit should be installed as high on the
wall as possible, allowing a minimum of 200mm from ceiling.
Use a stud finder to locate studs to prevent unnecessary damage to the wall.

9-10

More than
200mm
More than
500mm

More than
500mm
More than 1500mm

Indoor unit

ART COOL Gallery

9.2 Preparing Work for Installation


Open panel front
1. Pull the upper part of the front panel.
2. Lift up the panel.
3. To detach the front panel, remove the two screws at the lower part.
4. Detach the front panel from the body.
ART COOL Gallery

5. To detach the panel, disconnect the connector at the upper part.

Panel Front
Connector

Cover pipe and cover side remove


1. Please remove the screw of the center tuning cover.
2. Pull up the side cover of desired connecting direction, then
cover side is separated.
3. Pick the pipe hole of the side cover.

CAUTION: After removing the pipe hole,


cut the burr for safety.

Pipe hole
Side cover

NOTICE

When making pipe path through rear


wall, you dont need to pick the pipe hole.

Drain hose junction


1. Remove the rubber stopple in the desired drain
direction.
2. Insert drain hose into the handle of drain pan, and
join drain hose and connecting hose according to
the figure by.
Adhesive

Onlythe
the
Only
desired
desireddirection
direction

Connecting
part
Drain
hose

ART COOL Gallery

Indoor unit

rubber cap

9-11

ART COOL Gallery

9.3 Fixing Indoor Unit


1. Attach an Installation guide map on the
desired surface.
INSTALLATION GUIDE MAP

2. Look at suited horizon by horizontal


meter on the horizontal setting line, and
fix lightly the map by adhesive tape.
Horizontality

3. Make a hole with a diameter of 6mm and


depth of 30-35mm by piercing a screw
point.
IN
ST
AII
AT
IO
N

IN
ST
AL
LA
TIO
N

GU
ID
EM
AP

4. Drill the pierted part as a diameter of 50mm


for connecting piping. (In case of piercing
rear surface)

GU
ID
EM
AP

5. Drive the fore plastic anchors into drilled


points.
IN
ST
AL
LA
TIO
N

6. First, Drive the two points of the upper


parts by screws. (Leave 10mm for hanging
the product)

GU
ID
EM
AP

mm

10

Plastic anchors

7. Hang the hole of product at the upper


screws, and remove the map. (Falling
attention)
INS
TAL
LAT
ION
GUID
EM
AP

IN
ST
AL
LA
TIO
N

GU

8. Drive the lower parts after facing the hole


of product with plastic anchors, and fix
completely the upper screws.
Plastic anchors

Hanger hole
(Rear side of
the product)

9. Check the fixed product with light power.

9-12

10. In case of nothing wrong, connect the


pipe and the wire. (Refer to installation
manual)

Indoor unit

ART COOL Gallery

9.4 Connecting the Piping


Preparing the indoor unit's piping and drain hose for
installation through the wall.
1. Route the indoor tubing and the drain hose in
the direction of rear left or right

3. Connecting the pipings to the in door unit and


drain hose to drain pipe
Align the center of the pipings and sufficiently
tighten the flare nut by hand.

Flare nut

ART COOL Gallery

Indoor unit tubing

Pipings

Tighten the flare nut with a wrench.

Drain hose

Spanner (fixed)
Flare nut

2. Tape the tubing, drain hose and the connecting


cable. Be sure that the drain hose is located at
the lowest side of the bundle. Locating at the
upper side can cause drain pan to overflow
inside the unit.

Torque wrench

Connection pipe

Indoor unit tubing

When extending the drain hose at the indoor


unit, install the drain pipe.

Drain pipe

Loop

Connecting
cable

Gas side piping


Liquid side piping

Drain hose

CAUTION: If the drain hose is routed


inside the room, insulate the hose with
an insulation material* so that dripping
from "sweating"(condensation) will not
damage furniture or floors.
*Foamed polyethylene or equivalent is
recommended.

ART COOL Gallery

Indoor unit drain hose


Adhesive

Vinyl tape(narrow)

4. Wrap the insulation material around the connecting portion.


Overlap the connecting pipe insulation material
and the indoor unit pipe insulation material. Bind
them together with vinyl tape so that there is no
gap.

Plastic bands Insulation material

Indoor unit

9-13

ART COOL Gallery

CAUTION: Installation Information


For right piping. Follow the instruction below.
Good case
Press on the upper side of clamp and unfold the tubing to downward slowly.

Bad case
Following bending type from left to right may cause damage to the turbing.

9.5 Drain Piping


1) To check the drainage.
Pour a glass of water on the evaporator.
Ensure the water flows through the drain hose of
the indoor unit without any leakage and goes out
the drain exit.

2) Drain piping
The drain hose should point downward for easy
drain flow.
Downward slope

Do not make drain piping.


Tip of drain hose
dipped in water

Accumulated
drain water

Do not raise

Less than
50mm gap

Air

Water
leakage

9-14

Water
leakage

Waving

Indoor unit

Water
leakage

Ditch

ART COOL Gallery

9.6 Panel Front Assembly


1. First, Check the side cover assembly
exactly, and fix the power cord in the
bottom groove of cover side left.

ART COOL Gallery

2. Assemble connecting lead wire with


controller, fix the upper part of panel
front, and match the lower part of panel
front.
Panel Front
Connector

3. Screw up panel front, and suspend the


hook of panel front in the groove.

ART COOL Gallery

Indoor unit

9-15

ART COOL Gallery

9.7 Connect the cable to the Indoor unit.


Connect the cable to the indoor unit by connecting the wires to the terminals on the control board individually according to the outdoor unit connection. (Ensure that the color of the wires of the outdoor unit
and the terminal No. are the same as those of the indoor unit.)
The earth wire should be longer than the common wires.
Terminal Block Indoor
1(L)

2(N)

SODU

INTERNET DRY1 DRY2 GND 12V

IDU
-

Outdoor
Unit

INDOOR POWER INPUT

CAUTION
When installing, refer to the circuit diagram on the
Control Box of Indoor Unit.
When installing, refer to the wiring diagram on the
Control Cover Inside Outdoor Unit.

CAUTION
The above circuit diagram is subject to change without notice.
Be sure to connect wires according to the wiring diagram.
Connect the wires firmly, so that not to be pulled out
easily.
Connect the wires according to color codes by referring the wiring diagram.

9-16

After the confirmation of the above conditions,


prepare the wiring as follows:
1) Never fail to have separate power circuit specifically for the air conditioner. As for the method
of wiring, follow the circuit
diagram posted on the inside of control cover.
2) The screw which fasten the wiring in the casing
of electrical fittings are liable to come loose
from vibrations to which the unit is subjected
during the course of transportation. Check
them and make sure that they are all tightly
fastened. (If they are loose, it could cause
burn-out of the wires.)
3) Confirm the specification of power source.
4) Confirm that electrical capacity is sufficient.
5) See to that the starting voltage is maintained at
more than 90 percent of the rated voltage
marked on the name plate.
6) Confirm that the cable thickness is as specified
in the power source specification.
(Particularly note the relation between cable
length and thickness.
7) Always install an earth leakage circuit breaker
in a wet or moist area.
8) The following would be caused by voltage drop.
Vibration of a magnetic switch, which will damage
the contact point, fuse breaking, disturbance of
the normal function of the overload.
9) The means for disconnection from a power
supply shall be incorporated in the fixed wiring
and have an air gap contact separation of at
least 3mm in each active(phase) conductor.

Indoor unit

ART COOL Gallery

WIRED REMOTE CONTROLLER INSTALLATION


Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.

Do not install the remote controller where it can be affected by:

TEMP

ART COOL Gallery

- Drafts, or dead spots behind doors and in corners.


- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)

yes

Remote Controller

no

TEMP

Controller
Remote

TEMP

Remote Controller

5feet
(1.5meters)

no

no

Fig.1 Typical locations for remote controller

ART COOL Gallery

Indoor unit

9-17

ART COOL Gallery

10. Accessories
Standard Accessories
Name

Installation guide map

Quantity

1 EA

Type "A" screws and


plastic anchors

(Other)

4 SET
Owner's manual
Installation manual

Shape

CAUTION
Use only those accessories (Standard or optional) which have designated specifications.

9-18

Indoor unit

ART COOL Gallery

1. List of functions
2. Specifications
3. Dimensions
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. Electric Characteristics
8. Sound Levels
9. Installation
10. Accessories

Ceiling & Floor


Ceiling Suspended

Indoor unit

Ceiling & Floor/Ceiling Suspended

Ceiling & Floor


Ceiling Suspended

1. List of functions

Ceiling & Floor/Ceiling Suspended

Category

Air flow

Air purifying

Installation

Reliability

Convenience

Individual
control

Special
function kit

Function
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Wide wired remote controller
Deluxe wired remote controller
Simple wired remote controller
Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
Zone control
CTIE
Electro thermostat

ARNU09GVEA2, ARNU12GVEA2
ARNU18GVJA2, ARNU24GVJA2
1
Manual
Auto
X
O
3/4/3
X
O
O
X
X
O
X
X
X
O
O
O
O
O(Heat recovery)
X
O(Heat pump or Cooling only)
O
O
O
O
O
O
O
O
Accessory
Accessory
Accessory
Accessory
X
Accessory
-

O : Applied
X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

10-1

Indoor unit

Ceiling & Floor


Ceiling Suspended

2. Specifications

Cooling Capacity

Heating Capacity

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h

Casing
Dimensions(WxDxH) Body
Coil

Fan

Rows x Columns x FPI


Face Area
Type
Motor Output x Number
Running Current
Air Flow Rate(H/M/L)

mm
inch
m2
W
A
CMM
cfm

Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Safety Device
Liquid Side
mm(inch)
Pipe Connections Gas Side
mm(inch)
Drain Pipe(Internal Dia.)
mm
Net Weight
kg(lbs)
Noise Level(Sound Press, 1.5m, H/M/L) dB(A)3
Power Supply
Refrigerant Control
Power cable
Transmission cable
Color

, V, Hz
mm2
mm2

Ceiling & Floor


ARNU09GVEA2
ARNU12GVEA2
2.8
3.6
2,400
3,100
9,600
12,300
3.2
4.0
2,800
3,400
10,900
13,600
900x200x490
900x200x490
35.4x7.9x19.3
35.4x7.9x19.3
2x12x20
2x12x20
0.10
0.10
Cross Flow Fan
Cross Flow Fan
27
27
0.15
0.15
7.6/6.9/6.2
9.2/7.6/6.9
268/243/219
325/268/244
Direct
Direct
BLDC
BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene
Foamed polystrene
Fuse
Fuse
6.35(1/4)
6.35(1/4)
12.7(1/2)
12.7(1/2)
16
16
13.7(30.2)
13.7(30.2)
36/32/28
38/36/30
1, 220 ~ 240, 50
1, 220 ~ 240, 50
1, 220, 60
1, 220, 60
EEV
EEV
CV1.5 x 3C
CV1.5 x 3C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
Morning fog
Morning fog

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve

Ceiling & Floor


Ceiling Suspended

Indoor unit

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

10-2

Ceiling & Floor/Ceiling Suspended

Type
Model

Ceiling & Floor/Ceiling Suspended

Type
Model
Cooling Capacity

Heating Capacity

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h

Casing
Dimensions(WxDxH) Body
Coil

Fan

Rows x Columns x FPI


Face Area
Type
Motor Output x Number
Running Current
Air Flow Rate(H/M/L)

mm
inch
m2
W
A
CMM
cfm

Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Safety Device
Liquid Side
mm(inch)
Pipe Connections Gas Side
mm(inch)
Drain Pipe(Internal Dia.)
mm
Net Weight
kg(lbs)
Noise Level(Sound Press, 1.5m, H/M/L) dB(A)3
Power Supply
Refrigerant Control
Power cable
Transmission cable
Color

, V, Hz
mm2
mm2

Ceiling Suspended
ARNU18GVJA2
ARNU24GVJA2
5.6
7.1
4,800
6,100
19,100
24,200
6.3
8.0
5,400
6,900
21,500
27,300
Galvanized Steel Plate+Painting
Galvanized Steel Plate+Painting
950x220x650
950x220x650
37.4x8.7x25.6
37.4x8.7x25.6
3x14x19
3x14x19
0.23
0.23
Sirocco Fan
Sirocco Fan
60
60
0.30
0.30
16/ 14 /12
18/16/14
565/495/424
636/565/495
Direct
Direct
BLDC
BLDC
Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Foamed polystrene
Foamed polystrene
Fuse
Fuse
6.35(1/4)
9.52(3/8)
12.7(1/2)
15.88(5/8)
16
16
24.6(54.2)
24.6(54.2)
42/40/37
43/41/39
1, 220 ~ 240, 50
1, 220 ~ 240, 50
1, 220, 60
1, 220, 60
EEV
EEV
CV1.5 x 3C
CV1.5 x 3C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
Morning fog
Morning fog

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve

10-3

Indoor unit

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

Ceiling & Floor


Ceiling Suspended

Air suction grill

Indoor unit
587

<Ceiling Installation>

Air discharge grill

900
1

24
2

490

Air discharge grill


Air suction grill

1
2

490

Descripition

(unit : mm)

200

(unit : mm)

CHASSIS CODE: VE

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Note

Name

900

ARNU09GVEA2
ARNU12GVEA2

Number

ARNU09GVEA2
ARNU12GVEA2

Ceiling & Floor

Model

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

<Floor Installation>

200

Signal receiver & Operation indicator

273

Ceiling & Floor


Ceiling Suspended

10-4

Ceiling & Floor/Ceiling Suspended

879

3. Dimensions

950

800

41

650

10-5

Indoor unit

Ceiling & Floor


Ceiling Suspended

Note

650

Descripition

(unit : mm)

220

(unit : mm)

CHASSIS CODE: VJ

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Air suction grill

1
2

Name
Air discharge grill

Number

950

ARNU18GVJA2
ARNU24GVJA2

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

(Ceiling Suspended type)

220

Model

ARNU18GVJA2
ARNU24GVJA2

Ceiling Suspended

Ceiling & Floor/Ceiling Suspended

4. Piping Diagrams
VE

Th3

EEV

:Cooling
:Heating

Filter

Th2
C.F.F.

Th1

Filter

lndoor unit

VJ
Heat Exchanger

EEV

:Cooling
:Heating

Filter

Th2

Th3
Sirocco Fan

Th1

Filter

lndoor unit

Refrigerant pipe connection port diameter


[Unit: mm(inch)]

Model

Gas

Liquid

ARNU09GVEA2

12.7(1/2)

6.35(1/4)

ARNU12GVEA2

12.7(1/2)

6.35(1/4)

ARNU18GVJA2

12.7(1/2)

6.35(1/4)

ARNU24GVJA2

15.88(5/8)

9.52(3/8)

LOC.

Description

Th1

Room thermistor

Th2

Pipe in thermistor

Th3

Pipe out thermistor

Ceiling & Floor


Ceiling Suspended

Indoor unit

10-6

Ceiling & Floor/Ceiling Suspended

Heat Exchanger

5. Wiring Diagrams

Ceiling & Floor/Ceiling Suspended

VE Chassis

CONNECTOR
NUMBER
CN-POWER
CN-MOTOR1
CN-MOTOR2
CN-PIPE/OUT
CN-PIPE/IN
CN-ROOM
CN-REMO
CN-FLOAT
CN-EEV
CN-OPTION
CN-COM
CN-D/PUMP
CN-POWER
CN-DISPLAY
CN-DOOR
CN-CC

SPEC.

DESCRIPTION

AC power supply
Fan motor output
Fan motor output
Discharge pipe sensor
Suction pipe sensor
Room sensor
Remote controller
Float switch input
EEV output
Option pwb.
Communication
Drain pump output
AC power supply
Display wire
Door lock switch
Dry contact

AC power line input for indoor controller


Motor output of BLDC
Motor output of BLDC
Pipe out thermistor
Pipe in thermistor
Room thermistor
Remote control line
Float switch sensing
EEV Control output
Communication between main and option
Communication between indoor and outdoor
AC Output for drain pump
AC Power line input for indoor controller
Display wire line
Door lock switch line
Dry contact line

Dip Switch Setting


SW3
GROUP

Off
Master

On
Slave

SW4

DRY CONTACT

Variable

Auto

SW5

EXTRA 1

Off

On

Remarks
Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

10-7

Indoor unit

Ceiling & Floor


Ceiling Suspended

VJ Chassis
Ceiling & Floor/Ceiling Suspended

CONNECTOR
NUMBER
CN-POWER
CN-MOTOR1
CN-MOTOR2
CN-PIPE/OUT
CN-PIPE/IN
CN-ROOM
CN-REMO
CN-FLOAT
CN-EEV
CN-OPTION
CN-COM
CN-D/PUMP
CN-POWER
CN-DISPLAY
CN-DOOR
CN-CC

SPEC.

DESCRIPTION

AC power supply
Fan motor output
Fan motor output
Discharge pipe sensor
Suction pipe sensor
Room sensor
Remote controller
Float switch input
EEV output
Option pwb.
Communication
Drain pump output
AC power supply
Display wire
Door lock switch
Dry contact

AC power line input for indoor controller


Motor output of BLDC
Motor output of BLDC
Pipe out thermistor
Pipe in thermistor
Room thermistor
Remote control line
Float switch sensing
EEV Control output
Communication between main and option
Communication between indoor and outdoor
AC Output for drain pump
AC Power line input for indoor controller
Display wire line
Door lock switch line
Dry contact line

Dip Switch Setting


SW3
GROUP

Off
Master

On
Slave

SW4

DRY CONTACT

Variable

Auto

SW5

EXTRA 1

Off

On

Remarks
Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

Ceiling & Floor


Ceiling Suspended

Indoor unit

10-8

6. Capacity Tables

Ceiling & Floor/Ceiling Suspended

6.1 Cooling Capacity

Cooling capacity

20
14
TC SHC
kW kW

23
16
TC SHC
kW kW

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

2.8

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6

2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8

2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
2.9
2.9

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.3
3.2
3.2
3.1
3.1
3.0
3.0
2.9

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.0
2.0
2.0
1.9
1.9
1.9

3.7
3.6
3.6
3.5
3.5
3.4
3.4
3.4
3.3
3.3
3.2
3.2
3.1
3.1
3.0
3.0

2.1
2.1
2.1
2.0
2.0
2.0
2.0
1.9
1.9
1.9
1.9
1.8
1.8
1.8
1.8
1.7

3.6

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1

2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9

2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6

2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6

3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.7
3.7

2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.5

4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.2
4.1
4.1
4.0
4.0
3.9
3.8
3.7

2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.7
2.6
2.6
2.6
2.5
2.5
2.4
2.4

4.7
4.7
4.6
4.6
4.5
4.4
4.4
4.3
4.3
4.2
4.2
4.1
4.0
4.0
3.9
3.8

2.7
2.7
2.7
2.6
2.6
2.5
2.5
2.5
2.5
2.4
2.4
2.4
2.3
2.3
2.3
2.2

5.6

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8

3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3

4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5

3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7

5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2

4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0

5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6

4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0

6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
5.8
5.7

4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.1
4.0

6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.6
6.4
6.4
6.3
6.2
6.0
5.9
5.8

4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.2
4.1
4.1
4.0
3.9
3.8
3.8

7.4
7.3
7.2
7.1
7.0
6.9
6.8
6.7
6.6
6.6
6.5
6.4
6.3
6.2
6.1
6.0

4.3
4.2
4.2
4.1
4.1
4.0
4.0
3.9
3.9
3.8
3.8
3.7
3.7
3.6
3.6
3.5

Capacity
Index

Outdoor
air temp.
(DB, C)

Notes:
TC: Total Capacity(kW)

10-9

30
22
TC SHC
kW
kW

32
24
TC SHC
kW kW

SHC: Sensible Heat Capacity(kW)

Indoor unit

Ceiling & Floor


Ceiling Suspended

Cooling capacity

Outdoor
air temp.
(DB, C)

7.1

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

Notes:
TC: Total Capacity(kW)

Ceiling & Floor


Ceiling Suspended

20
14
TC SHC
kW kW

23
16
TC SHC
kW kW

4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8

5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7

6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6

4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2

4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6

5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0

7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1

5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1

7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.4
7.2

5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.3
5.1
5.0

30
22
TC SHC
kW
kW
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.4
8.2
8.1
8.0
7.8
7.7
7.5
7.4

5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.4
5.3
5.2
5.1
5.1
5.0
4.9
4.8

32
24
TC SHC
kW kW
9.3
9.2
9.1
9.0
8.8
8.7
8.7
8.5
8.4
8.3
8.2
8.1
7.9
7.8
7.7
7.6

5.4
5.4
5.3
5.2
5.2
5.1
5.1
5.0
4.9
4.9
4.8
4.7
4.6
4.6
4.5
4.4

SHC: Sensible Heat Capacity(kW)

Indoor unit

10-10

Ceiling & Floor/Ceiling Suspended

Capacity
Index

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

Ceiling & Floor/Ceiling Suspended

6.2 Heating Capacity


Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

Heating capacity
Indoor air temp. (DB, C)

16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

kW

kW

kW

kW

kW

kW

2.8

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

2.1
2.2
2.3
2.5
2.6
2.7
2.8
2.8
2.9
3.0
3.2
3.4
3.6
3.6
3.7
3.7
3.7
3.7
3.7

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.9
3.0
3.2
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

2.1
2.2
2.3
2.2
2.3
2.4
2.5
2.5
2.6
2.7
2.8
3.0
3.1
3.2
3.2
3.2
3.2
3.2
3.2

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.8
3.0
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.8
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0

2.1
2.2
2.3
2.4
2.6
2.7
2.7
2.7
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8

3.6

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

2.7
2.8
2.9
3.1
3.2
3.4
3.4
3.5
3.6
3.8
4.0
4.2
4.4
4.5
4.6
4.6
4.6
4.6
4.6

2.7
2.8
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.8
4.0
4.2
4.3
4.3
4.3
4.3
4.3
4.3
4.3

2.7
2.8
2.9
2.7
2.9
3.0
3.1
3.2
3.3
3.4
3.5
3.7
3.9
4.0
4.0
4.0
4.0
4.0
4.0

2.6
2.8
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.7
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9

2.6
2.7
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.7
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8

2.6
2.7
2.9
3.0
3.2
3.4
3.4
3.4
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5

5.6

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

4.2
4.3
4.6
4.9
5.1
5.4
5.4
5.5
5.7
6.0
6.2
6.6
7.0
7.1
7.2
7.2
7.2
7.2
7.2

4.2
4.3
4.6
4.8
5.1
5.4
5.4
5.5
5.7
6.0
6.2
6.6
6.7
6.7
6.7
6.7
6.7
6.7
6.7

4.2
4.3
4.6
4.3
4.5
4.8
4.9
5.0
5.1
5.4
5.5
5.8
6.2
6.3
6.3
6.3
6.3
6.3
6.3

4.2
4.3
4.6
4.8
5.0
5.4
5.4
5.5
5.6
5.8
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1

4.2
4.3
4.6
4.8
5.0
5.3
5.4
5.5
5.6
5.8
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9

4.2
4.3
4.5
4.8
5.0
5.3
5.4
5.4
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

Notes:
TC: Total Capacity(kW)

10-11

Indoor unit

Ceiling & Floor


Ceiling Suspended

Heating capacity

7.1

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

Indoor air temp. (DB, C)


16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

kW

kW

kW

kW

kW

kW

5.4
5.5
5.8
6.2
6.5
6.8
6.9
7.0
7.3
7.6
7.9
8.4
8.9
9.0
9.2
9.2
9.2
9.2
9.2

5.4
5.5
5.8
6.1
6.5
6.8
6.9
7.0
7.3
7.6
7.9
8.4
8.6
8.6
8.6
8.6
8.6
8.6
8.6

5.4
5.5
5.8
5.5
5.8
6.0
6.2
6.3
6.5
6.8
7.0
7.4
7.8
8.0
8.0
8.0
8.0
8.0
8.0

5.3
5.5
5.8
6.1
6.4
6.8
6.9
7.0
7.1
7.4
7.7
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8

5.3
5.4
5.8
6.1
6.4
6.7
6.9
7.0
7.1
7.4
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5

5.3
5.4
5.8
6.1
6.4
6.7
6.8
6.8
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0

Notes:
TC: Total Capacity(kW)

Ceiling & Floor


Ceiling Suspended

Indoor unit

10-12

Ceiling & Floor/Ceiling Suspended

Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

7. Electric Characteristics
Units
Ceiling & Floor/Ceiling Suspended

Model

Type

ARNU09GVEA2
ARNU12GVEA2
ARNU18GVJA2
ARNU24GVJA2

VE
VE
VJ
VJ

ARNU09GVEA2
ARNU12GVEA2
ARNU18GVJA2
ARNU24GVJA2

VE
VE
VJ
VJ

Power Supply
Hz

50

Volts

220 ~ 240

60

220

Voltage Range MCA


Max:264
Min:198

Max:242
Min:198

IFM

Input(W)

MFA

kW

FLA

Cooling Heating

1.22
1.22

15
15

0.027
0.027

0.17
0.17

30
30

30
30

1.43
1.43

15
15

0.060
0.060

0.35
0.35

63
63

63
63

1.22
1.22
1.43
1.43

15
15
15
15

0.027
0.027
0.060
0.060

0.17
0.17
0.35
0.35

30
30
63
63

30
30
63
63

Symbols:
MCA: Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
IFM : Indoor Fan Motor
Note :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA + 1
MFA 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the MCA.
5. Instead of fuse, use Circuit Breaker.

10-13

Indoor unit

Ceiling & Floor


Ceiling Suspended

8. Sound Levels
Overall

1m

1m
Microphone

Model

Sound Levels dB(A)


M
L

Model

Ceiling & Floor/Ceiling Suspended

Notes:
- Data is valid at nominal operating condition
- Reference accoustic pressure OdB = 20Pa
- Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment is installed.

Sound Levels dB(A)


M
L

ARNU09GVEA2

36

32

28

ARNU18GVJA2

42

40

37

ARNU12GVEA2

38

36

30

ARNU24GVJA2

43

41

39

Sound Pressure Level


ARNU18GVJA2

ARNU12GVEA2
80

70

70

70

NC-65
60
NC-60
NC-55

50

NC-50
NC-45
40
NC-40
NC-35

30

NC-30

NC-25

20
Approximate
Hearing
Threshold

NC-60

NC-50
NC-45
40
NC-40

250

500

1000

2000

4000

8000

Octave Band Center Frequency (Hz)

NC-35

30

NC-30

NC-25

20
Approximate
Hearing
Threshold

NC-15
125

NC-55

50

NC-20

10
63

NC-65
60

NC-65
60
NC-60

NC-15
125

250

500

1000

2000

4000

8000

Octave Band Center Frequency (Hz)

NC-55

50

NC-50
NC-45
40
NC-40
NC-35

30

NC-30

NC-25

20
Approximate
Hearing
Threshold

NC-20

10
63

Octave Band Sound Pressure Level (dB re 20Pa )

80

Octave Band Sound Pressure Level (dB re 20Pa )

Octave Band Sound Pressure Level (dB re 20Pa )

ARNU09GVEA2
80

NC-20
NC-15

10
63

125

250

500

1000

2000

4000

8000

Octave Band Center Frequency (Hz)

ARNU24GVJA2
80

Octave Band Sound Pressure Level (dB re 20Pa )

70

NC-65
60
NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30

20

10

NC-25
Approximate
Hearing
Threshold
63

NC-20
NC-15
125

250

500

1000

2000

4000

8000

Octave Band Center Frequency (Hz)

Ceiling & Floor


Ceiling Suspended

Indoor unit

10-14

Ceiling & Floor/Ceiling Suspended

9. Installation
Please read this instruction sheet completely before installing the product.
When the power cord is damaged, replacement work shall be performed by authorized personnel only.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

9.1 Features
9.1.1 VE Chassis

Vertical louver

Horizontal louver
Air outlet vent

Air filters
(behind front panel)
Air inlet vent

10-15

Indoor unit

Ceiling & Floor


Ceiling Suspended

9.1.2 VJ Chassis
Ceiling & Floor/Ceiling Suspended

Air Discharge

Right Side Cover

Signal Receptor

Air Filter

Left Side Cover

Inlet Grill

Drain hose

Ceiling & Floor


Ceiling Suspended

Indoor unit

10-16

Ceiling & Floor/Ceiling Suspended

VE Chassis
9.2 Installation Map
NOTICE

Installation parts you should purchase.

There should be no gap between


the ceiling and the unit.

Ceiling Mounting

Sleeve
Bushing-Sleeve
Putty(Gum Type Sealer)
More than
200mm
(Left and right
are identical)

More than 50mm

Bend the pipe as closely


on the wall as possible,
but be careful that it
doesn't break.

Wall Mounting

More than
200mm
(Left and right
are identical)

Vinyl tape (Wide)


To carry out the drainage
test, remove the air filters
and pour water into the heat
exchanger.
Apply after carrying out a
drainage test.

More than 50mm

Saddle

10-17

Indoor unit

Ceiling & Floor


Ceiling Suspended

9.3 Select the best Location


More than 200mm

1. Do not have any heat or steam near the unit.


More than 200mm

2. Select a place where there are no obstacles in front


of the unit.
3. Make sure that condensation drainage can be conveniently routed away.

More than 50mm

4. Do not install near a doorway.


5. Ensure that the interval between a wall and the left
(or right) of the unit is more than 200mm. The unit
should be installed as low as possible on the wall,
allowing a minimum of 500mm from floor.

More than 200mm

6. Use a stud finder to locate studs to prevent unnecessary damage to the wall.
More than 50mm

More than 200mm

9.4 Preparing Work for Installation


Open panel front
1. Remove the five screws.
2. Release the claws in the 3 places indicated.
3. Pull up the Front Panel.

2 Claw

Cover pipe and cover side remove


1. Pull up the side cover of desired connecting direction,
then cover side is separated.
2. Pick the pipe hole of the side cover.

CAUTION: After removing the pipe


hole, cut the burr for safety.
NOTICE

When making pipe path through rear


wall, you dont need to pick the pipe hole.

Drain hose junction


1. Remove the rubber stopple in the desired drain direction.
2. Insert drain hose into the handle of drain pan, and
join drain hose and connecting hose according to the
figure as shown on the right.

Ceiling & Floor


Ceiling Suspended

Indoor unit

10-18

Ceiling & Floor/Ceiling Suspended

Indoor unit

Ceiling & Floor/Ceiling Suspended

9.5 Mounting the installation plate(Wall Mounting)


The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. While mounting the unit on a concrete wall, use anchor bolts.
Mount the installation plate horizontally by aligning
the centerline using a level.

2. Measure the wall and mark the centerline. It is also


important to use caution concerning the location of
the installation plate-routing of the wiring to power
outlets is through the walls typically. Drilling the
hole through the wall for piping connections must
be done safely.

Installation Plate

Type "A" screw

70

70
Installation plate

70mm

120

70mm

more than 2000


Left rear piping

Right rear piping


Floor

10-19

Indoor unit

Ceiling & Floor


Ceiling Suspended

9.6 Mounting the anchor Nut & Bolt(Ceiling Mounting)


Measure and mark the position for the Suspension
bolts and the piping hole.
Drill the hole for anchor nut on the ceiling.

Anchor nut
Ceiling
Nut

Washer

Suspension
bolts

Insert the nuts and washer onto the suspension


bolts for locking the suspension bolts on the ceiling.

40

235
820

Suspension bolt

50
100

Mount the suspension bolts to the anchor-nuts firmly.


Secure the hangers onto the Suspension bolts
(adjust level roughly.) using nuts, washers and spring
washers.

Reference
of piping
hole (45)

piping hole
(45)

Adjust a level with a level gauge on the direction of


left-right, back-forth by adjusting suspension bolts.
Adjust a level on the direction of top-bottom by
adjusting supension bolts. Then the unit will be
inclined to the bottomside so as to drain well.

: Tighten the nut and bolt to prevent unit falling.

Suspension
bolts
Spring
washer
Hangen
Max.
12mm

Nut

Washer

Hanging bolt
(W3/8 or M10)
Nut
(W3/8 or M10)

Flat washer for M10


(accessory)

Flat washer for M10


(accessory)
Nut
(W3/8 or M10)

Ceiling & Floor


Ceiling Suspended

Indoor unit

10-20

Ceiling & Floor/Ceiling Suspended

Prepare 4 suspension bolts. (Each bolts length


should be same.)

Ceiling & Floor/Ceiling Suspended

: Installation Information For right piping. Follow the instruction below.

Good case

Bad case

For left piping. Follow the instruction below.

1. Following bending type from right to


left could cause problem of pipe damage.

1. Press on the upper side of clamp. ( )


2. Unfold the tubing downward slowly. ( )
3. Bend the tubing to the left side of chassis.

10-21

Indoor unit

Ceiling & Floor


Ceiling Suspended

9.7 Checking the Drainage


Ceiling & Floor/Ceiling Suspended

1. Set the air direction louvers up-and-down to the position(horizontally) by hand.

To check the drainage.


1. Pour a glass of water on the evaporator using a kettle.
2. Ensure the water flows through the drain hose of the
indoor unit without any leakage and goes out the
drain exit.
Checking the Drainage
1. Remove the Air Filter.
To remove air filter, take hold of tab and pull slightly
upwards.
2. Check the drainage.
Spray one or two glasses of water upon the evaporator.
Ensure that water flows drain hose of indoor unit
without any leakage.

Downward slope

Drain piping
1. The drain hose should point downward for easy drain
flow.
2. Do not make drain piping like the following.

Do not raise

Water
leakage

Water
leakage

Accumulated
drain water
Air

Waving

Less than
50mm gap

Tip of drain hose


dipped in water

Water
leakage

Ditch

9.8 Panel Front Assembly


1. Suspend the hook of panel front in the groove.
2. Press the panel front.
1

3. Screw up panel front.

3
2

Ceiling & Floor


Ceiling Suspended

Indoor unit

10-22

Ceiling & Floor/Ceiling Suspended

VJ Chassis
9.9 Select the best Location
Indoor unit
1. Do not have any heat or steam near the unit.

More than
700mm

2. Select a place where there are no obstacles in


front of the unit.
3. Make sure that condensation drainage can be
conveniently routed away.
4. Do not install near a doorway.
5. Ensure that the interval between a wall and the
left (or right) of the unit is more than 700mm.
6. Use a stud finder to locate studs to prevent
unnecessary damage to the wall.

More than
700mm

More than
300mm

: In case that the unit is installed near the sea, the installation parts may be cor-

roded by salt. The installation parts (and the unit) should be treated with appropriate anti-corrosion measures.

10-23

Indoor unit

Ceiling & Floor


Ceiling Suspended

9.10 Preparing Work for Installation

2. Unlock side-cover from side panel by slightly


pulling the edge of side cover.

2
Edge part

3. Tap the side-cover with your palm on the backside.(Inlet grill side.)
4. Hold the side-cover with other hand while tapping to prevent it to fall down.

5. Remove the rubber stopple in the desired drain


direction.
6. Knock out the pipe hole from the left side-cover
with the help or nipper/plier.
7. Knock hole on right side-cover only if right side
is selected for water drain.

Ceiling & Floor


Ceiling Suspended

Indoor unit

10-24

Ceiling & Floor/Ceiling Suspended

Open side cover


1. Remove two screws from side-cover as shown in
fig.

Prepare 4 suspension bolts. (Each bolts length


should be same.)

(Unit: mm)
DIM.

855

320

MODEL
VJ

Measure and mark the position for the


Suspension bolts and the piping hole.
Drill the hole for anchor nut on the ceiling.
Insert the nuts and washer onto the suspension
bolts for locking the suspension bolts on the ceiling.
Mount the suspension bolts to the anchor-nuts
firmly.

Anchor nut

Ceiling

Suspension bolt
Nut

Washer

Suspension
bolts

Secure the hangers onto the Suspension bolts


(adjust level roughly.) using nuts, washers and
spring washers.
Adjust a level with a level gauge on the direction
of left-right, back-forth by adjusting suspension
bolts.
Suspension
bolts

Adjust a level on the direction of top-bottom by


adjusting supension bolts. Then the unit will be
inclined to the bottomside so as to drain well.

Spring
washer
Hangen

Nut

Max.
12mm

: Tighten the nut and bolt to prevent unit falling.

Washer

Hanging bolt
(W3/8 or M10)
Nut
(W3/8 or M10)

Flat washer for M10


(accessory)

Flat washer for M10


(accessory)
Nut
(W3/8 or M10)

DRILL A HOLE IN THE WALL.

WALL
Indoor

Outdoor

10-25

Indoor unit

(3/16"~5/16")

Drill the piping hole with a 70mm hole core drill.


Drill the piping hole at either the right or the left
with the hole slightly slanted to the outdoor side.

5-7mm

Ceiling & Floor/Ceiling Suspended

MOUNTING THE ANCHOR NUT AND


BOLT

Ceiling & Floor


Ceiling Suspended

9.11 Indoor unit installation

: Installation Information For Declination

1. Inclination of the indoor unit is very important for drain purposes in the convertible
type air conditioner.
2. Minimum thickness of the insulation for the connecting pipe shall be 10mm.
3. If the Installation Plates are fixed to horizontal line, the indoor unit after installing will be
declined to the bottomside.

Front of view
The unit must be horizontal or inclined at angle.
The inclination should be less than or equal to 1 or in between 10 to 20mm inclined in drain direction as
shown in fig.
Ceiling
10~20mm

Side of view
The unit must be inclined to the bottomside of the unit when finished installation.
Ceiling

Ceiling & Floor


Ceiling Suspended

Indoor unit

10-26

Ceiling & Floor/Ceiling Suspended

Hang the Indoor unit on suspension bolt as per following guidelines:


1. Lift the indoor unit to sufficient height.
2. Insert the suspended part of four suspension bolt in the four hangers provided on the side of main body one by one.
3. Lower the indoor unit till the hangers rest on their respective flat washer.
4. Adjust the level in the top down direction by adjusting the suspension bolts.
Inclined the indoor unit as per direction provided in the fig

Ceiling & Floor/Ceiling Suspended

9.12 Checking the Drainage


1. Set the air direction louvers up-and-down to the position(horizontally) by hand.

To check the drainage.


1. Pour a glass of water on the evaporator using a kettle.
2. Ensure the water flows through the drain hose of the
indoor unit without any leakage and goes out the
drain exit.

Drain piping
Downward slope

1. The drain hose should point downward for easy drain


flow.

2. Do not make drain piping like the following.


Accumulated
drain water
Air

Do not raise

Water
leakage

10-27

Water
leakage

Waving

Tip of drain hose


dipped in water

Water
leakage

Indoor unit

Less than
50mm gap

Ditch

Ceiling & Floor


Ceiling Suspended

9.13 Wiring Connection

Terminal Block Indoor


1(L)

2(N)

SODU

INTERNET DRY1 DRY2 GND 12V

IDU
-

Outdoor
Unit

INDOOR POWER INPUT

WARNING : Make sure that the screws of the terminal are free from looseness.

Ceiling & Floor


Ceiling Suspended

Indoor unit

10-28

Ceiling & Floor/Ceiling Suspended

Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of
indoor unit respectively.

Ceiling & Floor/Ceiling Suspended

CAUTION:
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have a separate power circuit specially for the air conditioner. As for the method of
wiring, follow the circuit diagram posted on the inside of control box cover.
2) Provide a circuit breaker switch between power source and the unit.
3) The screws which fasten the wiring in the casing of electrical fittings are liable to come loose
from vibrations to which the unit is subjected during the course of transportation. Check them
and make sure that they are all tightly fastened. (If they are loose, it could give rise to burn-out of
the wires.)
4) Specification of power source
5) Confirm that electrical capacity is sufficient.
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage
marked on the name plate.
7) Confirm that the cable thickness is as specified in the power sources specification. (Particularly
note the relation between cable length and thickness.)
8) Never fail to equip a leakage breaker where it is wet or moist.
9) The following troubles would be caused by voltage drop-down.
Vibration of a magnetic switch, damage on the contact point, fuse breaking, disturbance by the normal
function of an overload protection device.
Proper starting power is not given to the compressor.

10-29

Indoor unit

Ceiling & Floor


Ceiling Suspended

WIRED REMOTE CONTROLLER INSTALLATION

Do not install the remote controller where it can be affected by:


- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)

TEMP

yes

Remote Controller

no

TEMP

Controller
Remote

TEMP

Remote Controller

5feet
(1.5meters)

no

no

Fig.1 Typical locations for remote controller

Ceiling & Floor


Ceiling Suspended

Indoor unit

10-30

Ceiling & Floor/Ceiling Suspended

Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.

10. Accessories

Ceiling & Floor/Ceiling Suspended

Standard Accessories
Name

Installation plate

Type "A" screw and


plastic anchor

Quantity

1EA

4EA

(Other)

Owner's manual
Installation manual
Shape

CAUTION
Use only those accessories (Standard or optional) which have designated specifications.

10-31

Indoor unit

Ceiling & Floor


Ceiling Suspended

1. List of functions
2. Specifications
3. Dimensions
4. Piping Diagrams
5. Wiring Diagrams
6. Capacity Tables
7. Air Velocity and Temperature Distribution
8. Electric Characteristics
9. Sound Levels
10. Installation
11. Accessories

Floor Standing

Indoor unit

Floor Standing

Floor Standing

1. List of functions

Floor Standing

Category

Air flow

Air purifying

Installation

Reliability

Convenience

Individual
control

Special
function kit

Function
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Deodorizing filter
Plasma air purifier
Prefilter(washable / anti-fungus)
Drain pump
E.S.P. control
Electric heater(operation)
High ceiling operation
Hot start
Self diagnosis
Soft dry operation
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Wide wired remote controller
Deluxe wired remote controller
Simple wired remote controller
Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
Zone control
CTIE
Electro thermostat

ARNU07GCEA2, ARNU09GCEA2, ARNU12GCEA2


ARNU15GCEA2, ARNU18GCFA2, ARNU24GCFA2
ARNU07GCEU2, ARNU09GCEU2, ARNU12GCEU2
ARNU15GCEU2, ARNU18GCFU2, ARNU24GCFU2
1
3/3/3
X
X
O
X
O
X
O
O
O
O(Heat recovery)
X
O(Heat pump or Cooling only)
O
O
O
X
O
O
O
Accessory
Accessory
Accessory
Accessory
X
Accessory
-

O : Applied
X : Not applied : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

11-1

Indoor unit

Floor Standing

2. Specification
Type
Model
Cooling Capacity

Heating Capacity

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h

Dimensions(WxDxH) Body
Coil

Fan

Rows x Columns x FPI


Face Area
Type
Motor Output x Number
Running Current
Air Flow Rate(H/M/L)

mm
inch
m2
W
A
CMM
cfm

Drive
Motor type
Temperature Control

Sound Absorbing Thermal Insulation Material


Air Filter
Safety Device
Liquid Side
mm(inch)
Pipe Connections Gas Side
mm(inch)
Drain Pipe(Internal Dia.)
mm
Net Weight
kg(lbs)
Noise Level(Sound Press, 1m, H/M/L)
dB(A)3
Power Supply
Refrigerant Control
Power cable
Transmission cable

, V, Hz
mm2
mm2

Floor Standing
ARNU09GCEA2
2.8
2,400
9,600
3.2
2,800
10,900
Galvanized
Steel Plate
1,067x203x635
42.2x8.0x25.0
2x12x19
0.16
Sirocco Fan
28
0.15
9.5/8.5/7.5
335/300/265
Direct
BLDC
Microprocessor,
Thermostat for
cooling and heating
Foamed polystrene
Resin Net(washable)
Fuse
6.35(1/4)
12.7(1/2)
12
27(59.5)
36/34/32
1, 220 ~ 240, 50
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.25 x 2C

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve

Floor Standing

Indoor unit

ARNU12GCEA2
3.6
3,100
12,300
4.0
3,400
13,600
Galvanized
Steel Plate
1,067x203x635
42.2x8.0x25.0
2x12x19
0.16
Sirocco Fan
28
0.15
10.5/9.5/8.5
371/335/300
Direct
BLDC
Microprocessor,
Thermostat for
cooling and heating
Foamed polystrene
Resin Net(washable)
Fuse
6.35(1/4)
12.7(1/2)
12
27(59.5)
37/35/33
1, 220 ~ 240, 50
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.25 x 2C

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

11-2

Floor Standing

Casing

ARNU07GCEA2
2.2
1,900
7,500
2.5
2,200
8,500
Galvanized
Steel Plate
1,067x203x635
42.2x8.0x25.0
2x12x19
0.16
Sirocco Fan
28
0.15
8.5/7.5/6.5
300/265/229
Direct
BLDC
Microprocessor,
Thermostat for
cooling and heating
Foamed polystrene
Resin Net(washable)
Fuse
6.35(1/4)
12.7(1/2)
12
27(59.5)
35/33/31
1, 220 ~ 240, 50
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.25 x 2C

Floor Standing

Type
Model
Cooling Capacity

Heating Capacity

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h

Casing
Dimensions(WxDxH) Body
Coil

Fan

Rows x Columns x FPI


Face Area
Type
Motor Output x Number
Running Current
Air Flow Rate(H/M/L)

mm
inch
m2
W
A
CMM
cfm

Drive
Motor type
Temperature Control

Sound Absorbing Thermal Insulation Material


Air Filter
Safety Device
Liquid Side
mm(inch)
Pipe Connections Gas Side
mm(inch)
Drain Pipe(Internal Dia.)
mm
Net Weight
kg(lbs)
Noise Level(Sound Press, 1m, H/M/L)
dB(A)3
Power Supply
Refrigerant Control
Power cable
Transmission cable

, V, Hz
mm2
mm2

ARNU07GCEU2
2.2
1,900
7,500
2.5
2,200
8,500
Galvanized
Steel Plate
978x190x639
38.5x7.5x25.2
2x12x19
0.16
Sirocco Fan
28
0.15
8.5/7.5/6.5
300/265/229
Direct
BLDC
Microprocessor,
Thermostat for
cooling and heating
Foamed polystrene
Resin Net(washable)
Fuse
6.35(1/4)
12.7(1/2)
12
20(44.1)
35/33/31
1, 220 ~ 240, 50
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.25 x 2C

Floor Standing
ARNU09GCEU2
2.8
2,400
9,600
3.2
2,800
10,900
Galvanized
Steel Plate
978x190x639
38.5x7.5x25.2
2x12x19
0.16
Sirocco Fan
28
0.15
9.5/8.5/7.5
335/300/265
Direct
BLDC
Microprocessor,
Thermostat for
cooling and heating
Foamed polystrene
Resin Net(washable)
Fuse
6.35(1/4)
12.7(1/2)
12
20(44.1)
36/34/32
1, 220 ~ 240, 50
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.25 x 2C

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve

11-3

Indoor unit

ARNU12GCEU2
3.6
3,100
12,300
4.0
3,400
13,600
Galvanized
Steel Plate
978x190x639
38.5x7.5x25.2
2x12x19
0.16
Sirocco Fan
28
0.15
10.5/9.5/8.5
371/335/300
Direct
BLDC
Microprocessor,
Thermostat for
cooling and heating
Foamed polystrene
Resin Net(washable)
Fuse
6.35(1/4)
12.7(1/2)
12
20(44.1)
37/35/33
1, 220 ~ 240, 50
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.25 x 2C

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

Floor Standing

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve

Floor Standing

Indoor unit

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

11-4

Floor Standing

Floor Standing
ARNU15GCEA2
ARNU18GCFA2
ARNU24GCFA2
4.5
5.6
7.1
3,900
4,800
6,100
Cooling Capacity
15,400
19,100
24,200
5.0
6.3
8.0
4,300
5,400
6,900
Heating Capacity
17,100
21,500
27,300
Galvanized Steel Plate
Galvanized Steel Plate
Galvanized Steel Plate
Casing
1,067x203x635
1,345x203x635
1,345x203x635
mm
Dimensions(WxDxH) Body
42.2x8.0x25.0
52.9x8.0x25.0
52.9x8.0x25.0
inch
2x12x19
3x11x19
3x11x19
Rows
x
Columns
x
FPI
Coil
0.16
0.23
0.23
Face Area
m2
Sirocco Fan
Sirocco Fan
Sirocco Fan
Type
28
76
76
Motor Output x Number
W
0.15
0.38
0.38
Running Current
A
11.5/10/9.5
16/14/12
18/16/14
Fan
Air Flow Rate(H/M/L)
CMM
406/353/335
565/494/424
635/565/494
cfm
Direct
Direct
Direct
Drive
BLDC
BLDC
BLDC
Motor type
Microprocessor, Thermostat Microprocessor, Thermostat Microprocessor, Thermostat
Temperature Control
for cooling and heating
for cooling and heating
for cooling and heating
Foamed polystrene
Foamed polystrene
Foamed polystrene
Sound Absorbing Thermal Insulation Material
Resin Net(washable)
Resin Net(washable)
Resin Net(washable)
Air Filter
Fuse
Fuse
Fuse
Safety Device
6.35(1/4)
6.35(1/4)
9.52(3/8)
Liquid Side
mm(inch)
12.7(1/2)
12.7(1/2)
15.88(5/8)
Pipe Connections Gas Side
mm(inch)
12
12
12
Drain Pipe(Internal Dia.)
mm
27(59.5)
34(75.0)
34(75.0)
Net Weight
kg(lbs)
38/37/35
40/37/34
43/40/37
Noise Level(Sound Press, 1m, H/M/L)
dB(A)3
1, 220 ~ 240, 50
1, 220 ~ 240, 50
1, 220 ~ 240, 50
Power Supply
, V, Hz
1, 220, 60
1, 220, 60
1, 220, 60
EEV
EEV
EEV
Refrigerant Control
CV1.5 x 3C
CV1.5 x 3C
CV1.5 x 3C
Power cable
mm2
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
Transmission cable
mm2
Type
Model

Floor Standing
ARNU15GCEU2
ARNU18GCFU2
ARNU24GCFU2
4.5
5.6
7.1
3,900
4,800
6,100
Cooling Capacity
15,400
19,100
24,200
5.0
6.3
8.0
4,300
5,400
6,900
Heating Capacity
17,100
21,500
27,300
Galvanized Steel Plate
Galvanized Steel Plate
Galvanized Steel Plate
Casing
978x190x639
1,256x190x639
1,256x190x639
mm
Dimensions(WxDxH) Body
38.5x7.5x25.2
49.5x7.5x25.2
49.5x7.5x25.2
inch
2x12x19
3x11x19
3x11x19
Rows
x
Columns
x
FPI
Coil
0.16
0.23
0.23
Face Area
m2
Sirocco Fan
Sirocco Fan
Sirocco Fan
Type
28
76
76
Motor Output x Number
W
0.15
0.38
0.38
Running Current
A
11.5/10/9.5
16/14/12
18/16/14
Fan
Air Flow Rate(H/M/L)
CMM
406/353/335
565/494/424
635/565/494
cfm
Direct
Direct
Direct
Drive
BLDC
BLDC
BLDC
Motor type
Microprocessor, Thermostat Microprocessor, Thermostat Microprocessor, Thermostat
Temperature Control
for cooling and heating
for cooling and heating
for cooling and heating
Foamed polystrene
Foamed polystrene
Foamed polystrene
Sound Absorbing Thermal Insulation Material
Resin Net(washable)
Resin Net(washable)
Resin Net(washable)
Air Filter
Fuse
Fuse
Fuse
Safety Device
6.35(1/4)
6.35(1/4)
9.52(3/8)
Liquid Side
mm(inch)
12.7(1/2)
12.7(1/2)
15.88(5/8)
Pipe Connections Gas Side
mm(inch)
12
12
12
Drain Pipe(Internal Dia.)
mm
20(44.1)
27(59.5)
27(59.5)
Net Weight
kg(lbs)
38/37/35
40/37/34
43/40/37
Noise Level(Sound Press, 1m, H/M/L)
dB(A)3
1, 220 ~ 240, 50
1, 220 ~ 240, 50
1, 220 ~ 240, 50
Power Supply
, V, Hz
1, 220, 60
1, 220, 60
1, 220, 60
EEV
EEV
EEV
Refrigerant Control
CV1.5 x 3C
CV1.5 x 3C
CV1.5 x 3C
Power cable
mm2
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
CVV-SB 1.25 x 2C
Transmission cable
mm2

Floor Standing

Type
Model

Unit
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h

Notes:1. Capacities are based on the following conditions:


Cooling Indoor temp. 27C[80.6F]DB/ 19C[66.2F]WB
Outdoor temp. 35C[95F]DB/ 24C[75.2F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
Heating Indoor temp. 20C[68F]DB/ 15C[59F]WB
Outdoor temp. 7C[44.6F]DB/ 6C[42.8F]WB
Interconnecting Piping Length 7.5m
Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve

11-5

Indoor unit

Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m3/min x 35.3
l/s = CMM x 1000/60

Floor Standing

Indoor unit

148.3

<Without Case>

978
794

<With Case> 2

1067

13

148.3

635
70
20.4
62.8

Floor Standing

11-6

190
161

203

14

Air discharge grill


Air suction grill

1
2

639

635

Descripition

(unit : mm)

190

203

(unit : mm)

ARNU07GCEU2
ARNU09GCEU2
ARNU12GCEU2
ARNU15GCEU2

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

CHASSIS CODE: CE

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Note

Name

978

ARNU07GCEU2
ARNU09GCEU2
ARNU12GCEU2
ARNU15GCEU2

Number

1067

ARNU07GCEA2
ARNU09GCEA2
ARNU12GCEA2
ARNU15GCEA2

Model

ARNU07GCEA2
ARNU09GCEA2
ARNU12GCEA2
ARNU15GCEA2

Floor Standing

Floor Standing

1067

3. Dimensions

49

639

21.4

639

Indoor unit

148.3

70

<Without Case>

1256
1098
1072

<With Case>

1048.4

1345

203
635
109.8
30

148.3

70
81.4
145

11-7

Floor Standing

49.4

190
161

203

14

Air discharge grill


Air suction grill

1
2

639

635

Descripition

(unit : mm)

190

203

(unit : mm)

ARNU18GCFU2
ARNU24GCFU2

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea

CHASSIS CODE: CF

2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

1. Unit should be installed in compliance with the installation manual


in the product box.

Note

Name

Number

1256

1345

ARNU18GCFA2
ARNU24GCFA2
ARNU18GCFU2
ARNU24GCFU2

Model

ARNU18GCFA2
ARNU24GCFA2

Floor Standing

Floor Standing

4. Piping Diagrams

Heat Exchanger

EEV

Filter

:Cooling
:Heating

Th2

Th3
Sirroco Fan

Floor Standing

Th1

Filter

lndoor unit

Refrigerant pipe connection port diameter


[Unit: mm(inch)]

Model
ARNU07GCEA2
ARNU07GCEU2
ARNU09GCEA2
ARNU09GCEU2
ARNU12GCEA2
ARNU12GCEU2
ARNU15GCEA2
ARNU15GCEU2
ARNU18GCFA2
ARNU18GCFU2
ARNU24GCFA2
ARNU24GCFU2

Floor Standing

Gas

Liquid

12.7(1/2)

6.35(1/4)

12.7(1/2)

6.35(1/4)

12.7(1/2)

6.35(1/4)

12.7(1/2)

6.35(1/4)

12.7(1/2)

6.35(1/4)

15.88(5/8)

9.52(3/8)

LOC.

Description

Th1

Room thermistor

Th2

Pipe in thermistor

Th3

Pipe out thermistor

Indoor unit

11-8

5. Wiring Diagrams

Floor Standing

CE/CF Chassis

CONNECTOR
NUMBER

CN-POWER
CN-MOTOR1
CN-MOTOR2
CN-COMM
CN-EEV
CN-PIPE/IN
CN-PIPE/OUT
CN-ROOM
CN-REMO
CN-OPTION
CN-ZONE
CN-DISPLAY
CN-CC

LOCATION POINT

FUNCTION

AC power supply
Fan motor output
Fan motor output
Communication
Float switch input
Suction pipe sensor
Discharge pipe sensor
Room sensor
Remote controller
Option PCB
Zone controller
RF Remote controller
Dry contact

AC Power line input for indoor controller


Motor output of BLDC
Motor output of BLDC
Communication between indoor and outdoor
EEV Control output
Pipe in thermistor
Pipe out thermistor
Room thermistor
Remote control line
Communication between main and option
Zone control line
RF Remote control line
Dry contact line

Dip Switch Setting


SW3
GROUP

Off
Master

On
Slave

SW4

DRY CONTACT

Variable

Auto

SW5

EXTRA 1

Off

On

Remarks
Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
remote controller or Wireless remote controller
(When shipped from Factory Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

11-9

Indoor unit

Floor Standing

6. Capacity Tables
6.1 Cooling Capacity
Capacity
Index

2.8

3.6

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

Notes:
TC: Total Capacity(kW)

Floor Standing

20
14
TC SHC
kW kW

23
16
TC SHC
kW kW

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

30
22
TC SHC
kW
kW

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.5
2.5
2.5
2.4
2.4
2.3
2.3
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.3
3.2
3.2
3.1
3.1
3.0
3.0
2.9
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.2
4.1
4.1
4.0
4.0
3.9
3.8
3.7

1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6

2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7

2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.2
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
2.9
2.9
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.7
3.7

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.5
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.0
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.6

1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.6
1.6
1.6
1.5
1.5
1.5
1.5
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.1
2.1
2.1
2.0
2.0
1.9
1.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.8
2.8
2.7
2.7
2.6
2.6
2.5
2.5

32
24
TC SHC
kW kW
2.9
2.9
2.8
2.8
2.7
2.7
2.7
2.6
2.6
2.6
2.5
2.5
2.5
2.4
2.4
2.3
3.7
3.6
3.6
3.5
3.5
3.4
3.4
3.4
3.3
3.3
3.2
3.2
3.1
3.1
3.0
3.0
4.7
4.7
4.6
4.6
4.5
4.4
4.4
4.3
4.3
4.2
4.2
4.1
4.0
4.0
3.9
3.8

1.7
1.6
1.6
1.6
1.6
1.6
1.5
1.5
1.5
1.5
1.5
1.4
1.4
1.4
1.4
1.4
2.2
2.1
2.1
2.1
2.1
2.0
2.0
2.0
2.0
1.9
1.9
1.9
1.9
1.8
1.8
1.8
2.8
2.8
2.8
2.7
2.7
2.7
2.6
2.6
2.6
2.5
2.5
2.5
2.4
2.4
2.3
2.3

SHC: Sensible Heat Capacity(kW)

Indoor unit

11-10

Floor Standing

2.2

Outdoor
air temp.
(DB, C)

Cooling capacity

Floor Standing

Cooling capacity

20
14
TC SHC
kW kW

23
16
TC SHC
kW kW

Indoor air temp. (DB/WB, C)


26
27
28
18
19
20
TC SHC TC SHC TC SHC
kW
kW
kW kW
kW kW

30
22
TC SHC
kW
kW

Capacity
Index

Outdoor
air temp.
(DB, C)

4.5

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0

2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7

3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6

3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0

4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2

3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3

4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5

3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3

4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4

3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6

5.9
5.8
5.8
5.7
5.6
5.5
5.5
5.4
5.3
5.3
5.2
5.1
5.0
5.0
4.9
4.8

3.6
3.5
3.5
3.4
3.4
3.3
3.3
3.3
3.2
3.2
3.1
3.1
3.0
3.0
2.9
2.9

10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39

3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8

3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1

4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7

3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6

5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6

4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0

5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1

4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0

6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
5.8
5.7
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.4
7.2

4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.1
4.0
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.1
5.0

6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.7
6.6
6.4
6.4
6.3
6.2
6.0
5.9
5.8
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.4
8.2
8.1
8.0
7.8
7.7
7.5
7.4

4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.2
4.1
4.1
4.0
3.9
3.8
3.8
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.2
5.2
5.1
5.0
4.9
4.8
4.7

7.4
7.3
7.2
7.1
7.0
6.9
6.8
6.7
6.6
6.6
6.5
6.4
6.3
6.2
6.1
6.0
9.3
9.2
9.1
9.0
8.8
8.7
8.7
8.5
8.4
8.3
8.2
8.1
7.9
7.8
7.7
7.6

4.3
4.2
4.2
4.1
4.1
4.0
4.0
3.9
3.9
3.8
3.8
3.7
3.7
3.6
3.6
3.5
5.4
5.3
5.2
5.2
5.1
5.0
5.0
4.9
4.8
4.8
4.7
4.6
4.6
4.5
4.4
4.4

5.6

7.1

Notes:
TC: Total Capacity(kW)

11-11

32
24
TC SHC
kW kW

SHC: Sensible Heat Capacity(kW)

Indoor unit

Floor Standing

6.2 Heating Capacity


Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

Heating capacity
Indoor air temp. (DB, C)

16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

kW

kW

kW

kW

kW

2.2

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.3
2.4
2.5
2.6
2.8
2.8
2.9
2.9
2.9
2.9
2.9

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.3
2.4
2.5
2.6
2.7
2.7
2.7
2.7
2.7
2.7
2.7

1.7
1.7
1.8
1.7
1.8
1.9
1.9
2.0
2.0
2.1
2.2
2.3
2.4
2.5
2.5
2.5
2.5
2.5
2.5

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.2
2.3
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.2
2.2
2.3
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

1.7
1.7
1.8
1.9
2.0
2.1
2.1
2.1
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

2.8

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

2.1
2.2
2.3
2.5
2.6
2.7
2.8
2.8
2.9
3.0
3.2
3.4
3.6
3.6
3.7
3.7
3.7
3.7
3.7

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.9
3.0
3.2
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

2.1
2.2
2.3
2.2
2.3
2.4
2.5
2.5
2.6
2.7
2.8
3.0
3.1
3.2
3.2
3.2
3.2
3.2
3.2

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.8
3.0
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1

2.1
2.2
2.3
2.4
2.6
2.7
2.8
2.8
2.8
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0

2.1
2.2
2.3
2.4
2.6
2.7
2.7
2.7
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8

3.6

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

2.7
2.8
2.9
3.1
3.2
3.4
3.4
3.5
3.6
3.8
4.0
4.2
4.4
4.5
4.6
4.6
4.6
4.6
4.6

2.7
2.8
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.8
4.0
4.2
4.3
4.3
4.3
4.3
4.3
4.3
4.3

2.7
2.8
2.9
2.7
2.9
3.0
3.1
3.2
3.3
3.4
3.5
3.7
3.9
4.0
4.0
4.0
4.0
4.0
4.0

2.6
2.8
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.7
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9

2.6
2.7
2.9
3.0
3.2
3.4
3.4
3.5
3.6
3.7
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8

2.6
2.7
2.9
3.0
3.2
3.4
3.4
3.4
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5

Notes:
TC: Total Capacity(kW)
Capacity

Floor Standing

Indoor unit

11-12

Floor Standing

kW
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

Floor Standing

Heating capacity
Outdoor air
temp.
Capacity
Index
DB(C) WB(C)

4.5

5.6

7.1

-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7
-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7
-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

Indoor air temp. (DB, C)


16.0

18.0

20.0

21.0

22.0

24.0

TC

TC

TC

TC

TC

TC

kW

kW

kW

kW

kW

kW

3.4
3.5
3.7
3.9
4.1
4.3
4.3
4.4
4.6
4.8
5.0
5.3
5.6
5.6
5.8
5.8
5.8
5.8
5.8
4.2
4.3
4.6
4.9
5.1
5.4
5.4
5.5
5.7
6.0
6.2
6.6
7.0
7.1
7.2
7.2
7.2
7.2
7.2
5.4
5.5
5.8
6.2
6.5
6.8
6.9
7.0
7.3
7.6
7.9
8.4
8.9
9.0
9.2
9.2
9.2
9.2
9.2

3.4
3.5
3.7
3.8
4.1
4.3
4.3
4.4
4.6
4.8
5.0
5.3
5.4
5.4
5.4
5.4
5.4
5.4
5.4
4.2
4.3
4.6
4.8
5.1
5.4
5.4
5.5
5.7
6.0
6.2
6.6
6.7
6.7
6.7
6.7
6.7
6.7
6.7
5.4
5.5
5.8
6.1
6.5
6.8
6.9
7.0
7.3
7.6
7.9
8.4
8.6
8.6
8.6
8.6
8.6
8.6
8.6

3.4
3.5
3.7
3.4
3.6
3.8
3.9
4.0
4.1
4.3
4.4
4.6
4.9
5.0
5.0
5.0
5.0
5.0
5.0
4.2
4.3
4.6
4.3
4.5
4.8
4.9
5.0
5.1
5.4
5.5
5.8
6.2
6.3
6.3
6.3
6.3
6.3
6.3
5.4
5.5
5.8
5.5
5.8
6.0
6.2
6.3
6.5
6.8
7.0
7.4
7.8
8.0
8.0
8.0
8.0
8.0
8.0

3.3
3.5
3.7
3.8
4.0
4.3
4.3
4.4
4.4
4.6
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.2
4.3
4.6
4.8
5.0
5.4
5.4
5.5
5.6
5.8
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
5.3
5.5
5.8
6.1
6.4
6.8
6.9
7.0
7.1
7.4
7.7
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8

3.3
3.4
3.7
3.8
4.0
4.2
4.3
4.4
4.4
4.6
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.2
4.3
4.6
4.8
5.0
5.3
5.4
5.5
5.6
5.8
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.3
5.4
5.8
6.1
6.4
6.7
6.9
7.0
7.1
7.4
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5

3.3
3.4
3.6
3.8
4.0
4.2
4.3
4.3
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.2
4.3
4.5
4.8
5.0
5.3
5.4
5.4
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.3
5.4
5.8
6.1
6.4
6.7
6.8
6.8
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0

Notes:
TC: Total Capacity(kW)

11-13

Indoor unit

Floor Standing

7. Air velocity and Temperature Distribution(Reference Data)


ARNU24GCFA2- Installation on floor
Cooling

Heating

Discharge angle:45

Discharge angle:60

Air velocity [m/s]

Air velocity [m/s]


2.7m

2.7m
0.5
0.75

0.75

2m

2m

1.0

1.0

1m

1m

8m

7m

6m

5m

4m

3m

2m

0m
0m

1m

8m

7m

6m

5m

4m

3m

2m

0m
0m

1m

Temperature [C]

Temperature [C]

2.7m

2.7m
24

29
30

2m
25
23

8m

7m

6m

Floor Standing

5m

4m

3m

2m

1m

2m

28
1m

0m
0m

31

8m

7m

6m

Indoor unit

5m

4m

3m

2m

1m

1m

0m
0m

11-14

Floor Standing

1.25

1.25

8. Electric Characteristics
Units
Floor Standing

Model
ARNU07GCEA2
ARNU07GCEU2
ARNU09GCEA2
ARNU09GCEU2
ARNU12GCEA2
ARNU12GCEU2
ARNU15GCEA2
ARNU15GCEU2
ARNU18GCFA2
ARNU18GCFU2
ARNU24GCFA2
ARNU24GCFU2
ARNU07GCEA2
ARNU07GCEU2
ARNU09GCEA2
ARNU09GCEU2
ARNU12GCEA2
ARNU12GCEU2
ARNU15GCEA2
ARNU15GCEU2
ARNU18GCFA2
ARNU18GCFU2
ARNU24GCFA2
ARNU24GCFU2

Type

Power Supply
Hz

Volts Voltage Range MCA

CE
CE
CE

MAX.264
50

220~240

60

220

MIN.198

CE
CF
CF
CE
CE
CE

MAX.242
MIN.198

CE
CF
CF

1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.55
1.55
1.55
1.55
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.55
1.55
1.55
1.55

IFM

Input(W)

MFA

kW

FLA

15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15

0.028
0.028
0.028
0.028
0.028
0.028
0.028
0.028
0.076
0.076
0.076
0.076
0.028
0.028
0.028
0.028
0.028
0.028
0.028
0.028
0.076
0.076
0.076
0.076

0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.44
0.44
0.44
0.44
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.44
0.44
0.44
0.44

Cooling Heating
30
30
30
30
30
30
30
30
80
80
80
80
30
30
30
30
30
30
30
30
80
80
80
80

30
30
30
30
30
30
30
30
80
80
80
80
30
30
30
30
30
30
30
30
80
80
80
80

Symbols:
MCA: Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
IFM : Indoor Fan Motor
Note :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA
MFA 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the MCA.
5. Instead of fuse, use Circuit Breaker.

11-15

Indoor unit

Floor Standing

9. Sound Levels
Overall
Notes:
- Sound measured at 1.5m away from
the center of the unit.
- Data is valid at free field condition
- Data is valid at nominal operating condition
- Reference accoustic pressure OdB = 20Pa
- Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment is installed.

Microphone

With Case

1.5m

Expos

Duct

1.5m

ARNU07GCEA2
ARNU09GCEA2
ARNU12GCEA2
ARNU15GCEA2
ARNU18GCFA2
ARNU24GCFA2

ARNU07GCEU2
ARNU09GCEU2
ARNU12GCEU2
ARNU15GCEU2
ARNU18GCFU2
ARNU24GCFU2

Floor Standing

Model

(Field wo

Sound Levels dB(A)


H
L
M
35
33
31
36
34
32
37
35
33
38
37
35
40
37
34
43
40
37

Sound Pressure Level


ARNU07GCEA2
ARNU07GCEU2

ARNU09GCEA2
ARNU09GCEU2
70

NC-65

60

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
NC-25

20

10

Approximate
Hearing
Threshold
63

250

500

70

NC-65

60

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
20

NC-20

125

NC-15
1000 2000 4000 8000

10

63

NC-60

250

500

NC-50

NC-40

NC-30

NC-15
1000 2000 4000 8000

10

NC-65
NC-60
NC-55
NC-50
NC-45
NC-40
NC-35
NC-30

10

NC-25

63

NC-60

125

250

500

Octave Band Center Frequency (Hz)

Floor Standing

NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
20

NC-20
NC-15
1000 2000 4000 8000

NC-65

60

10

Octave Band Sound Pressure Level (dB re 20Pa )

70

Octave Band Sound Pressure Level (dB re 20Pa )

70

Approximate
Hearing
Threshold

125

NC-25
Approximate
Hearing
Threshold
63

250

500

1000

2000

4000

500

1000 2000

NC-15
4000 8000

NC-15
8000

Octave Band Center Frequency (Hz)

Indoor unit

NC-65

60

NC-60
NC-55

50

NC-50
NC-45

40

NC-40
NC-35

30

NC-30
20

NC-20

125

250

ARNU24GCFA2
ARNU24GCFU2

ARNU18GCFA2
ARNU18GCFU2

70

20

NC-20

Octave Band Center Frequency (Hz)

80

30

NC-25
Approximate
Hearing
Threshold
63

80

40

NC-35

30

80

50

NC-45

40

Octave Band Center Frequency (Hz)

ARNU15GCEA2
ARNU15GCEU2

60

NC-55

50

NC-20

125

NC-65

60

20

NC-25
Approximate
Hearing
Threshold

Octave Band Center Frequency (Hz)

Octave Band Sound Pressure Level (dB re 20Pa )

80

Octave Band Sound Pressure Level (dB re 20Pa )

70

Octave Band Sound Pressure Level (dB re 20Pa )

80

Octave Band Sound Pressure Level (dB re 20Pa )

80

ARNU12GCEA2
ARNU12GCEU2

10

NC-25
Approximate
Hearing
Threshold
63

NC-20

125

250

500

1000

2000

4000

NC-15
8000

Octave Band Center Frequency (Hz)

11-16

Floor Standing

10. Installation
Please read this instruction sheet completely before installing the product.
When the power cord is damaged, replacement work shall be performed by authorized personnel only.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

10.1 Features

[CEA/CFA Type]

Control panel

Air Outlet
Remote Controller
Control panel
TEMP

Remote Controller

Air Filter
Air Inlet

[CEU/CFU Type]

Air Inlet
Air filter
(At Air Inlet)

11-17

Indoor unit

Floor Standing

10.2 Selection of the best location


Indoor unit
Install the air conditioner in the location that satisfies the following conditions.
The place shall easily bear a load exceeding four times the
indoor units weight.
Sufficient space should be available to inspect the unit as in
the figure shown on the right.

Floor Standing

Window

The place where the unit is installed shall be leveled.


The place shall be suitable for easy connection of the indoor
unit with the outdoor unit.
The place where the unit is installed should not be affected
by electrical noise.
The place where air circulation in the room will be good .
There should not be any heat source or steam near the unit
Select an installation site where the following conditions are
satisfied and that meets your customer's approval.
Where the floor is strong enough to bear the indoor unit
weight.
Where the floor is not significantly inclined.

20 or
more

Service space

Air flow
direction
Front side

100 or
more

1000 or
more

Where nothing blocks the air passage.

175 or
more

100 or
more
Air inlet
direction

Where condensate can be properly drained.


Base

Where sufficient clearance for installation and maintenance


can be ensured.
Where there is no possibility of flammable gas leakage.
Where optimum air distribution can be ensured.
Where piping between indoor and outdoor units is possible
within the allowable limit (Refer to the installation manual of
the outdoor unit.)
80 or more

654

Keep the indoor and outdoor unit, power cable and transmission wiring, at least 1m from TVs and radios, to prevent distorted pictures and static.(Depending on the type and source
of the electrical waves, static may be heard even when more
than 1 m away.)

Window

Ma

CEU Type

788

1080

CFU Type

1066

1358

Floor Standing

nan

ce

are

Ao

(Unit: mm)
Type

inte

[IMPORTANT]
Leave sufficient clearance
for air inlet and maintenance.

Indoor unit

rm
ore
Bo
rm
ore

11-18

Positioning of holes for fastening to the wall

Type

CEA, CEU
CFA, CFU

858
1136

1. Use the installationmount for installation. Check


whether the wall is strong enough to bear the
weight of the unit or not. if there is a risk, reinforce
the wall before installing the unit.
2. The unit requires a minimum 100 mm clearance
below the unit for air intake. Also, ensure the unit is
leveled when installed so that drainage flows
smoothly. If inclined, water can leak.
3. Depending upon the shape and nature of the wall
surface, operating sound may become bigger.

198

(Unit:mm)

270

Floor Standing

Bolt pitch

How to open/close front panel

(1)

How to open/close the front panel


(2)

(1) Open the lid of control panel(Both left and right)


(2) Remove screws(Both left and right)
(3) Lift the front panel of the unit
To close, perform the procedure in opposite
order.

11-19

(2)
(3)

Indoor unit

(1)

Floor Standing

10.3 Drain piping work


Drain piping must have downward slope(1/50 to 1/100): be sure not to provide up-and-down slope to prevent
reverse flow.
During drain piping connection, be careful not to exert extra force on the drain port on the indoor unit.
The outside diameter of the drain connection to the indoor unit is 21mm.
Floor Standing

Piping material: Polyvinyl chloride pipe 25mm and


pipe fittings
Be sure to install heat insulation on the drain piping
Heat insulation material: Polyethylene foam with
thickness more than 10 mm.
If converging multiple drain pipes, install according to the procedure shown below.

Slope downwards at a gradient


of at least 1/100
After piping work is finished, check for drainage.
Be sure to insulate all indoor units.

10.4 How to connect wirings


Remove the electric parts Box cover and connect the wiring

Fasten with clamp

Fasten with
accessory clamp

Floor Standing

Power Supply wiring


ground wiring
(Field wiring)

Power supply wiring


ground wiring
Transmission wiring
(Field wiring)

Transmission wiring

Indoor unit

11-20

Floor Standing

10.5 Wiring Connection


Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively.
Terminal Block Indoor
1(L)

2(N)

SODU

INTERNET DRY1 DRY2 GND 12V

IDU
-

Outdoor
Unit

INDOOR POWER INPUT

WARNING : Make sure that the screws of the terminal are free from looseness.
CAUTION:
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have a separate power circuit specifically for the air conditioner. As for the method of
wiring, follow the circuit diagram posted on the inside of control cover.
2) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from
vibrations to which the unit is subjected during the course of transportation. Check them and make
sure that they are all tightly fastened. (If they are loose, it could cause burn-out of the wires.)
3) Specification of power source.
4) Confirm that electrical capacity is sufficient.
5) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked on
the name plate.
6) Confirm that the cable thickness is as specified in the power source specification.
(Particularly note the relation between cable length and thickness.)
7) In a wet or moist area, always install an earth leakage circuit breaker.
8) The following would be caused by voltage drop.
Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the normal function of the overload.
9) The means for disconnection from a power supply shall be incorporated in the fixed wiring and
have an air gap contact separation of at least 3mm in each active(phase) conductor.

11-21

Indoor unit

Floor Standing

WIRED REMOTE CONTROLLER INSTALLATION


Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.

Do not install the remote controller where it can be affected by:


Floor Standing

- Drafts, or dead spots behind doors and in corners.


- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)

TEMP

yes

Remote Controller

no

TEMP

Controller
Remote

TEMP

Remote Controller

5feet
(1.5meters)

no

no

Fig.1 Typical locations for remote controller

Floor Standing

Indoor unit

11-22

11. Accessories

Floor Standing

Standard Accessories
Name

Dran
hose

Level adjustment
screw

Insulation for
fitting

Clamp
(Tie Wrap)

Quantity

1 EA

1 each.

8 pcs.

(1) For gas pipe


Shape

[Other]

Operation
manual
Installation
manual

(2) For liquid pipe

CAUTION
Use only those accessories (Standard or optional) which have designated specifications.

11-23

Indoor unit

Floor Standing

P/No.: 3828A24007X

Air Conditioner
20 Yeouido-dong, Yeongdeungpo-gu,
Yeouido P.O.Box 335 Seoul,
150-721, Korea.
http://www.lgeaircon.com

All rights reserved


Printed in Korea January/2009
The specifications, designs, and
information in this brochure are subject to
change without notice.

File No. : A8974


Volume:1

Certificate No. :
E00626/1

The air conditioners manufactured by LG


have received ISO9001 certificate for
quality assurance and ISO14001
certificate for environmental
management system.

Você também pode gostar