Você está na página 1de 32

I -Rectangular Ducts:

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)

- Slip & Drive


- Slide-on Flange
- Companion Angle

II -Rectangular Ducts Welded

RECTANGULAR DUCTS

I -Rectangular Ducts:

- Slip & Drive


- Slide-on Flange
- Companion Angle

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)


DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

DVAC Is One Of The Premium Workshops For The Duct Fabrication & Fittings.
DVAC Has Executed Residential, Governmental, Commercial, Industrial, and Institutional Projects.

Table of Contents
I -Rectangular Ducts:

- Slip & Drive - Slide-on Flange - Companion Angle


Page
Fabrication Procedure

Bill Of Quantities Model

Longitudinal Seams

Fittings

7
8
9
10

Splitter Damper

11

Acoustic Liner Installation

12

Plenum Box

13

Slip & Drive

14

Companion Angle

15

Slide-on Flange

16

Suspension Flanges

17

Construction Schedule - SMACNA 1"

18

Construction Schedule - SMACNA 2

19

Construction Schedule - SMACNA 3

20

Construction Schedule - SMACNA 4

21

Construction Schedule - DW/144 500 Pa

22

Construction Schedule - DW/144 1000 Pa

23

Construction Schedule - DW/144 2000 Pa

24

II -Rectangular Ducts Welded


Longitudinal Seams and Connection

25

Fittings

26
27
28

Tables: - Coating Mass (Weight) - GI Thicknesses - Weight of GI Steel

DOHA QATAR PHONE: +974 4500118 +974 4500119 FAX: +974 4500117

29

I -Rectangular Ducts:
Fabrication Procedure
DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)
DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

FABRICATION PROCEDURE:
According to The Drawing / Take Off Provided by The Client,
DVAC Engineers Start The Operation Production Following The Consequent Steps:
a ) Shop Drawings to be Prepared Using CADmep.
b ) Accurate B.O.Qs to be Issued Including Accessories And Connectors (Refer to Page 5).
c ) An Estimation of The Cost Can be Provided to The Client Upon Issuance of B.O.Q.
d ) Fabrication Begins By CAMDuct Linked to CNC Machines Based On CAD-Duct Drawings.
e ) All Ductworks Are Fabricated According to SMACNA Or DW 142/144.
f ) Each Item to be Numbered On The Drawing Provided, Fabricated Items to be Labeled;
Each Label Shows The Project Name, Customer Name, Job Ref., Item Number, Item Description
(Straight Duct, Elbow, Tee, VCD, VAV, Silencer, Etc...), Size & Length, Thickness, Weight And Area.
g ) QA/QC to be Made For Each Item Before Collection (Delivery).
PB 300X300X3000 S12

BOD 2450

S10

350X300
S7

S11

S11

S11

S2

S2

S2

S7

S7

S14

S13

S9
S3

S2

S2

S3

S6

S6
BOD 2450

BOD 2450
S8

500X300
BOD 2800

S8
S5

S3

S2

S2

S3

S6

S6
BOD 2450

S4

BOD 2450

600X300
BOD 2800

S4

R5

R5

S1

FCU - 42TX-036
R4

R4
500X200

R1

R2

500X200

R3

R2

R1

BOD 2800

BOD 2800

Back to Index

I -Rectangular Ducts:
Bill Of Quantities - Model
DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)
DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

Customer: M/S. (Customer Name)


Project : (Project Name)
Job Ref.:
Contact Person:
Tel:
Page: 1/2

DUCTVENTILATIONAIR CONDITIONING Co. (WLL)

Description

S3
S11

Flex
Flex

Qty
4
3

MATERIALS: GALVANIZED x 0.60


Item No.
Description

Qty

Straight
Straight (Coil)
Straight (Coil)
Straight (Coil)
Cap End(Alt)
Straight (Cut)
Drop Cheek Bend
Taper

2
4
2
2
1
1
1
1

MATERIALS: GALVANIZED x 0.80


Item No.
Description
R4
R5
R1

Qty

Straight
Taper
Radius Bend

2
2
2

MATERIALS: GALVANIZED x 1.00


Item No.
Description
R3
S1

Qty

Breeches Piece
Taper

1
1

Description: Slot Plenum, Insulation:


Item No.
Description
S12

Job Date: 17/02/2010 Printing Date: 20/02/2010

Fax:

MATERIALS:
Item No.

R2
S7
S8
S4
S13
S14
S9
S5

Bill Of Quantities

Slot Plenum

Qty

1200 (mm)
600 (mm)

Duct Size
(mm)
500x200
350x300
500x300
600x300
350x300
350x300
500x300
600x300

1190
1190
1190
1190
0
560
90
360

Duct Size
(mm)
500x200
500x200
500x200

1190 (mm)
260 (mm)
90

Duct Size
(mm)
1234x200
1234x219

Width
(mm)
300

1
1

Description: FCU - 42TX-036


Item No.
Description
S44
FCU - 42TX-036

Duct Size
(mm)
200
200

Qty
1
1

Length/Angle

Length/Angle
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)

Length/Angle

Length/Angle

Height
(mm)
300

200 (mm)
560 (mm)

Length
(mm)
3000

Duct Size (mm)


1234x219

Prepared By:

Duct
Area

Total
Area

Duct
Weight

Total
Weight

Insulation
Area

Insulation

Duct
Area
1.75
1.62
1.99
2.23
0.25
0.79
1.38
1.06

Total
Area
3.49
6.48
3.97
4.46
0.25
0.79
1.38
1.06

Duct
Weight
8.36
7.78
9.53
10.70
1.20
3.77
6.62
5.07

Total
Weight
16.72
31.09
19.06
21.40
1.20
3.77
6.62
5.07

Insulation
Area

Insulation

Duct
Area
1.75
1.00
1.70

Total
Area
3.49
2.00
3.39

Duct
Weight
11.15
6.40
10.84

Total
Weight
22.29
12.80
21.68

Insulation
Area

Insulation

Duct
Area
3.73
1.99

Total
Area
3.73
1.99

Duct
Weight
29.80
15.90

Total
Weight
29.80
15.90

Insulation
Area

Insulation

Total Length (m)


3.00
3.00

Slot Dimension
(mm)
150

Neck Slot
Collar
Length (mm) Diameter
100
200

Collar
Qty
3
3

Length (mm)
600 (mm)

Customer Signature:

Approved By:

Customer: M/S. (Customer Name)


Project : (Project Name)
Job Ref.:
Contact Person:
Tel:
Page: 2/2

Bill Of Quantities
DUCTVENTILATIONAIR CONDITIONING Co. (WLL)

Fax:

Description: Linear Diffuser


Item No.
Description
S10
Linear Diffuser
Description: Rnd Single Blade Damper
Item No.
Description
S2
Rnd Single Blade Damper
Description: Supply Plenum Box
Item No.
Description
S6
Supply Plenum Box
Description: Canvas Connection
Item No.
Description
R6
Canvas Connection
S15
Canvas Connection

Job Date: 17/02/2010 Printing Date: 20/02/2010

Qty
1
1

Duct Size (mm)


3000x150

Length (mm)
25 (mm)

Qty
7
7

Duct Size (mm)


200

Length (mm)
200 (mm)

Qty
4
4

Duct Size (mm)


450x450

Length (mm)
100 (mm)

Qty
1
1
2

Duct Size (mm)


1234x200
1234x219

Length (m)
2.87
2.91
5.78

MATERIALS: GALVANIZED
Gauge
0.60
0.80
1.00

Total Area (sq m)


21.85
8.87
5.72
36.43

Total Weight (kg)


104.88
56.76
45.69
207.32

Connector Name: S"S&D. SLIP


Total Length "S" Cleat (m)
27.97

Total Length C Cleat (m)


12.39

Qty "S" Cleat L.1220mm


23

Qty C Cleat L.1220mm


11

Connector Name: S&D. SLIP


Total Length "S" Cleat (m)
10.26

Total Length C Cleat (m)


8.55

Qty "S" Cleat L.1220mm


9

Qty C Cleat L.1220mm


8

Connector Name: Wire Mesh


Item No
R5

Prepared By:

Depth (m)
0.20

Width (m)
0.50

Qty
2
2

Area
0.20
0.20

Customer Signature:

Approved By:

Back to Index

I -Rectangular Ducts:
Longitudinal Seams

- Slip & Drive


- Slide-on Flange
- Companion Angle

As per: - SMACNA (2nd Edition-1995) See Pages 1.17/1.67/1.74


- SMACNA (3rd Edition-2005) See Pages 2.10/2.113
- DW/144 See Page 20

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)

DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

Straight Ducts are Beaded or Crossbroken

Grooved Corner Seam

- Duct Sides that are 260mm and over, shall be


Crossbroken or Beaded.

- Galvanized Up to 20 Gage
- Stainless Steel Up to 22 Gage

152.5
305

305

305
152.5

Beading

Pittsburgh Lock Seam

Grooved Seam

- Galvanized 16 Gage Maximum


- Stainless Steel 20 Gage Maximum

- Galvanized 16 Gage Maximum


- Stainless Steel 20 Gage Maximum

* Materials Used for Ductworks :


- Galvanized Steel: (Standard)
L.F.Q. Complying with ASTM A653 and Having G90 Coating Designation.
- Stainless Steel : (Optional) Complying with ASTM A240M / A480M, Grade 304, 304L, 316, & 316L.
- Aluminum Metal : (Optional) Complying with ASTM B209, Alloy 3003, Temper H14.

* Can Be Supplied with Acoustic Lining or Double Wall


6

Back to Index

I -Rectangular Ducts:

- Slip & Drive


- Slide-on Flange
- Companion Angle

As per: - SMACNA (2nd Edition-1995) See Pages 2.3/2.9/A.42/A.43


- SMACNA (3rd Edition-2005) See Pages 4.3/4.9/4.12/4.13
- DW/144 See Pages 55/57

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)

DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

Straight

Taper

Standard Length 1220mm


While Using Slip & Drive Length Will be 1190mm
22.5 Max.

OW

W1 x D1

OD

W2 x D2

WxD

L1

L1

Radius Bend

Splitter Position
B
C

Width - mm

Splitters

400 - 800

W/3

801 - 1600

W/4

W/2

1601 - 2000

W/8

W/3

W/2

Medium Radius Bend (as illustrated)


Can be Applied to any Angle

Long Radius Bend

Splitters not Required in Bend Angles Less Than 45

Similar but Radius = Width


Can be Applied to any Angle

A
R

Minimum Throat Radius = 100mm


DVAC Standard Throat Radius = 150mm

WxD

Throat Radius = Width

WxD

D
Master Bend

Drop Cheek Bend


Can be Applied to any Angle

Outer R
W2 x D2

OD

W2 x D2

Inner R

W1 x D1

W1 x D1

* Materials Used for Ductworks :


- Galvanized Steel: (Standard)
L.F.Q. Complying with ASTM A653 and Having G90 Coating Designation.
- Stainless Steel : (Optional) Complying with ASTM A240M / A480M, Grade 304, 304L, 316, & 316L.
- Aluminum Metal : (Optional) Complying with ASTM B209, Alloy 3003, Temper H14.

* Can Be Supplied with Acoustic Lining or Double Wall


7

Back to Index

I -Rectangular Ducts:

- Slip & Drive


- Slide-on Flange
- Companion Angle

As per: - SMACNA (2nd Edition-1995) See Pages 2.8/2.9


- SMACNA (3rd Edition-2005) See Pages 4.8/4.9
- DW/144 See Pages 55/58

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)

DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

Shoe Branch

Width (W) mm
Up to 200

WxD

W2 x D2

75

,,

300

100

,,

400

125

,,

600

150

Over 600

200

Clinch Lock
(Optional)

Straight + 2 Branches

Dim. (A) mm

W1 x D1

Straight Tap
(DVAC Standard)

Duct

Duct

Sealant

Sealant
Fixing by Rivets or
Self-Tapping Screws

25mm

L1

25mm

Radius 2-Way Offset

Straight + Branch

W3 x D3

Minimum Throat Radius = 150mm


W2 x D2

OW

W1 x D1

W1 x D1

W2 x D2

OD

L1

L1

Mitered Offset

Radius Offset
Minimum Throat Radius = 150mm

30 Max.

OW

WxD

OW

W1 x D

E1
E2
W2
L1

L1

* Materials Used for Ductworks :


- Galvanized Steel: (Standard)
L.F.Q. Complying with ASTM A653 and Having G90 Coating Designation.
- Stainless Steel : (Optional) Complying with ASTM A240M / A480M, Grade 304, 304L, 316, & 316L.
- Aluminum Metal : (Optional) Complying with ASTM B209, Alloy 3003, Temper H14.

* Can Be Supplied with Acoustic Lining or Double Wall


8

Back to Index

I -Rectangular Ducts:

- Slip & Drive


- Slide-on Flange
- Companion Angle

As per: - SMACNA (2nd Edition-1995) See Pages 2.8/2.9/3.18


- SMACNA (3rd Edition-2005) See Pages 3.36/4.8/4.9
- DW/144 See Pages 55/58

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)

DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

Trousers Piece

Angled Offset

W2 x D2

W3 x D2

15 Max.

OW
WxD

OD

OW

W1 x D1
L1

Square to Round

Collar (Dovetail)
VCD Optional
75mm

22.5 Max.

OW

Sealant

OD

WxD

Crimped
Beaded
Duct
L1

Drop Cheek Breeches Piece

3-Way Tee
Splitter Damper Optional
W3

W2 x D2

OD2

OD3

W4

W3 x D3
W2

R2
R2

R1

R1

W1 x D1

W1 x D

Q
* Materials Used for Ductworks :

- Galvanized Steel: (Standard)


L.F.Q. Complying with ASTM A653 and Having G90 Coating Designation.
- Stainless Steel : (Optional) Complying with ASTM A240M / A480M, Grade 304, 304L, 316, & 316L.
- Aluminum Metal : (Optional) Complying with ASTM B209, Alloy 3003, Temper H14.

* Can Be Supplied with Acoustic Lining or Double Wall


9

Back to Index

I -Rectangular Ducts:

- Slip & Drive


- Slide-on Flange
- Companion Angle

As per: - SMACNA (2nd Edition-1995) See Page 2.7


- SMACNA (3rd Edition-2005) See Page 4.7
- DW/144 See Pages 52/55

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)

DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

Breeches Piece

Radius Tee

Splitter Damper Optional

W2

W3

W2

R2

R1

W3

R2

R1

W1 x D

W1 x D

Side Branch

2-Way Breeches

Splitter Damper Optional


W2 x D2

W2

OD2
W3

W3 x D3

OD3

R
W1 x D1

W1 x D

Flexible Connection

Plenum Box
Side or Top Connection

WxD

WxD

* Materials Used for Ductworks :


- Galvanized Steel: (Standard)
L.F.Q. Complying with ASTM A653 and Having G90 Coating Designation.
- Stainless Steel : (Optional) Complying with ASTM A240M / A480M, Grade 304, 304L, 316, & 316L.
- Aluminum Metal : (Optional) Complying with ASTM B209, Alloy 3003, Temper H14.

* Can Be Supplied with Acoustic Lining or Double Wall


10

Back to Index

I -Rectangular Ducts:
Splitter Damper

- Slip & Drive


- Slide-on Flange
- Companion Angle

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)


DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

Splitter Damper

Piano Hinge
Blade

Control Rod

Aerofoil Blade Splitter Damper


(DVAC Standard)

Splitter Damper Length (A x 1.5)

Piano Hinge

W2 x D2

Blade

W3 x D3

OD3

OD2

Single Blade Splitter Damper


Piano Hinge
Blade

A
W1 x D1

* Materials Used for Ductworks :


- Galvanized Steel: (Standard)
L.F.Q. Complying with ASTM A653 and Having G90 Coating Designation.
- Stainless Steel : (Optional) Complying with ASTM A240M / A480M, Grade 304, 304L, 316, & 316L.
- Aluminum Metal : (Optional) Complying with ASTM B209, Alloy 3003, Temper H14.

* Can Be Supplied with Acoustic Lining or Double Wall


11

Back to Index

I -Rectangular Ducts:
Duct Acoustic Liner

- Slip & Drive


- Slide-on Flange
- Companion Angle

As per: - SMACNA (2nd Edition-1995) See Pages 2.24/2.28


- SMACNA (3rd Edition-2005) See Pages 7.13/7.17

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)

DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

Acoustic Liner Installation


Insulation Guard
(DVAC Standard)

Insulation Guard
(Channel)

Liner

Duct

Liner

24 Gage

Rivets

Duct

Insulation Guard
(Zee)

Liner

Duct

24 Gage

Tog-L-Loc or Rivets

24 Gage

Liner

Rivets

Welding Pin

B
A

D
Alternate Folded Corner

E
B
E

Insulation Guard
Fixing byTog-L-Loc or Rivets
Welding Pin

"A" Pin Row May be Omitted when Metal Nosing is Used.


Then E Starts from the Nosing.
Dimensions
Velocity *
A

0 - 2500 FPM
(0 - 12.7 MPS)

3"
(76.2)

12"
(305)

4"
(102)

6"
(152)

18"
(457)

2501 - 6000 FPM


(12.7 - 30.5 MPS)

3"
(76.2)

12"
(305)

4"
(102)

6"
(152)

18"
(457)

All Transverse Edges to be Coated


with Adhesive, Except when Nosing
is present.

Liner Adhered to the Duct with 90%


Min. Area Coverage of Adhesive.

* Materials Used for Acoustic Liner :

: KIMMCO Clean Liner 15mm, 48 kg/m3, is Faced with a Black, Strong,


Durable, Dimensionally Stable Woven Glass Fabric.
- Adhesive
: Foster 80-10
- Duct Sealant : Foster 32-17
- Insulation

* Optional : - Acoustic Liner as per Client Request


12

Back to Index

I -Rectangular Ducts:
Plenum Box
As per: - SMACNA (2nd Edition-1995) See Page 2.20
- SMACNA (3rd Edition-2005) See Page 10.1

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)

DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

Plenum Box
* Plenum Box : Fabricated of 22 Gage Galvanized Steel
* Acoustic Liner : KIMMCO Clean Liner 15mm, 48 kg/m3, is Faced with a Black, Strong, Durable,
Dimensionally Stable Woven Glass Fabric.
* Optional :- Volume Control Damper.
- Inside Insulation Covered with Galvanized
Perforated Sheet Insuring Full Protection.
- Acoustic Liner as per Client Request.
Hanging Bracket

L + 50mm
Plenum Box
Acoustic Liner

B
Liner
Welding Pin
A

76mm
W

O2

Plenum Box
H

Tog-L-Loc or Rivets

Standard
76mm

End Cap

Crimped
O1

Beaded
Plenum Box
Insulation Guard
Tog-L-Loc or Rivets

* Liner Adhered to the Plenum Box with 100% Area Coverage of Adhesive.
* Welding Pins Fixation from Center to Center: 300mm.

* Materials Used for Ductworks :


- Galvanized Steel: (Standard)
L.F.Q. Complying with ASTM A653 and Having G90 Coating Designation.
- Stainless Steel : (Optional) Complying with ASTM A240M / A480M, Grade 304, 304L, 316, & 316L.
- Aluminum Metal : (Optional) Complying with ASTM B209, Alloy 3003, Temper H14.

13

Back to Index

I -Rectangular Ducts:
DVAC Accessories
As per: - SMACNA (2nd Edition-1995) See Pages 1.14/1.61
- SMACNA (3rd Edition-2005) See Pages 2.6/2.7/2.8
- DW/142 See Pages 28/31

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)

DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

Slip & Drive


Standing S

Duct

Hemmed S Slip
(DVAC Standard)

Standing S
(Optional)

Standing S 28.6
(DVAC Standard)

Standing S 41.3
(Optional)

Standing S 54
(Optional)

C1 / T-6

C2 / T-10

C2 / T-10

T-13

C3 / C4 / T-14
5
5

5
54
41.3
28.6

15

27

27

Thickness 0.6mm

Thickness 0.6mm

35
Thickness 0.6 to 1.0mm

35

35

Thickness 0.7 to 1.2mm

Thickness 1.0mm

Drive Slip

Backup Angle for Drive Slip

C1 / T-1

T-3

DVACStandard

Optional

28.5

28.5

Thickness 0.6 to 1.0mm

Thickness 0.8 to 1.2mm

75

28.5

* Materials Used for Duct Accessories :


- Galvanized Steel: (Standard)
L.F.Q. Complying with ASTM A653 and Having G90 Coating Designation.
- Stainless Steel : (Optional) Complying with ASTM A240M / A480M, Grade 304, 304L, 316, & 316L.
- Aluminum Metal : (Optional) Complying with ASTM B209, Alloy 3003, Temper H14.
* NOTE : Standard Length of Hemmed S, Standing S & Drive Slip is 1220mm.
14

Back to Index

I -Rectangular Ducts:
DVAC Accessories
DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)

As per: - SMACNA (2nd Edition-1995) See Pages 1.14/1.61


- SMACNA (3rd Edition-2005) See Pages 2.6/2.7/2.8
- DW/142 See Pages 28/31

DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

Companion Angles
J3 / J4 / J5 / J6 / T-22

Duct

Fixing by
Rivets or Screws

Companion Angle

Gasket

Dimensions

Rating

25 x 3

J3

30 x 4

J4

40 x 4

J5

- Duct Ends Turn up 10mm.


- Fixing Bolts at Each Corner
Intermediately Centers at 300mm.

50 x 5
J6
Fixing Bolts
25 x 3

6mm

30 x 4

8mm

40 x 4

8mm

50 x 5

10mm

* Materials Used for Duct Accessories :


- Galvanized Steel: (Standard)
L.F.Q. Complying with ASTM A653 and Having G90 Coating Designation.
- Stainless Steel : (Optional) Complying with ASTM A240M / A480M, Grade 304, 304L, 316, & 316L.
- Aluminum Metal : (Optional) Complying with ASTM B209, Alloy 3003, Temper H14.
* NOTE : Companion Angle & Reinforcement are Made of Primer Painted Black Steel Angle.
15

Back to Index

I -Rectangular Ducts:
VENTO Accessories
(BELGIUM)

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)


DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

Slide-on Flange

Duct

Lance-N-Locor Rivets

Flange

Drive Slip

Gasket

Flange System 20

Clamp with Screw

SR
E20

8.5

H20

18

CM
20

Thickness 0.7mm

SR40

25

73

8x20
Thickness 0.6mm
Thickness 1.0mm

Thickness 3.0mm

Thickness 0.7mm

Flange System 40

Thickness 2.5mm

Flange System 30

10
A40

H40

37

E30

8.5

H30
27

40
30

140

36
Thickness 0.9mm
Thickness 1.0mm

27

105

Thickness 0.7mm
Thickness 3.0mm

Thickness 0.8mm

Thickness 3.0mm

* Materials Used for Duct Accessories :


- Galvanized Steel: (Standard)
L.F.Q. Complying with ASTM A653 and Having G90 Coating Designation.
- Stainless Steel : (Optional) Complying with ASTM A240M / A480M, Grade 304, 304L, 316, & 316L.
- Aluminum Metal : (Optional) Complying with ASTM B209, Alloy 3003, Temper H14.
* NOTE : DVAC Standard Use For Flange System : - 20: Thickness 0.7mm
- 30: Thickness 0.8mm
- 40: Thickness 1.0mm
16

Back to Index

I -Rectangular Ducts:
VENTO Accessories
(BELGIUM)

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)


DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

VENTO Suspension Flanges


Type: U
L

14
14
14

2
1.5

50

35

20

1.5
30

30

30

Code

Length

Code

Length

Code

Length

U203

3m

U353

3m

U503

3m

U206

6m

U356

6m

U503

6m

Type: UP
L

10.5

50

24

14
14
14

1.5
1.5

20
30

30

Code

50

35

Length

Code

30

Length

Code

Length

UP203

3m

UP353

3m

UP503

3m

UP206

6m

UP356

6m

UP506

6m

* Materials Used for Duct Accessories :


- Galvanized Steel: (Standard)
L.F.Q. Complying with ASTM A653 and Having G90 Coating Designation.

17

Back to Index

I -Rectangular Ducts:
Ductwork Construction Schedule - Tables 1A / 1B / 1C - 1"
As per: - SMACNA (3rd Edition-2005 Table 2-2) See Page 2.16

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)

DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117


Transverse Connections

OPTION -1-

1"

Table 1A : 1" W.G. Static Positive or Negative


(as per SMACNA Third Edition - 2005 Table 2-2)

Duct Dimension
(mm)

Gage

Seam
Straight

Fittings

75

Intermediate
Reinforcement

T-1
Drive Slip

T-3
Drive Slip with
Backup Angle

T-6
Hemmed S
Slip

T-10
Standing S
H. 28.6mm

T-13
Standing S
H. 41.3mm

T-14
Standing S
H. 54mm

T-22
Companion
Angles

Slide-on
Flange

0 - 400

26

Grooved Corner

Pittsburgh Lock

Not Required

Gage 24

401 - 750

26

Grooved Corner

Pittsburgh Lock

Not Required

Gage 24

751 - 900

26

Grooved Corner

Pittsburgh Lock

Not Required

901 - 1200

24

Grooved Corner

Pittsburgh Lock

Not Required

Flange 20
Thickness 0.7mm

1201 - 1500

24

Grooved Corner

Pittsburgh Lock

Not Required

Flange 30
Thickness 0.8mm

1501 - 1800

22

Grooved Corner

Pittsburgh Lock

Not Required

Flange 30
Thickness 0.8mm

1801 - 2100

20

Grooved Corner

Pittsburgh Lock

Not Required

Flange 40
Thickness 1.0mm

2101 - 2700

18

Pittsburgh Lock

Pittsburgh Lock

Not Required

Flange 40
Thickness 1.0mm

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

Flange 40
Thickness 1.0mm

18

2701 - 3000

Pittsburgh Lock

Gage 24
Gage 22
Gage 22 +
25X25X3 Angle

Transverse Connections

OPTION -2-

1"

Table 1B : 1" W.G. Static Positive or Negative


(as per SMACNA Third Edition - 2005 Table 2-2)

Duct Dimension
(mm)

Gage

Seam
Straight

Fittings

Gage 20

75

Intermediate
Reinforcement

T-1
Drive Slip

T-3
Drive Slip with
Backup Angle

T-6
Hemmed S
Slip

T-10
Standing S
H. 28.6mm

T-13
Standing S
H. 41.3mm

T-14
Standing S
H. 54mm

T-22
Companion
Angles

0 - 400

26

Grooved Corner

Pittsburgh Lock

Not Required

Gage 24

401 - 750

26

Grooved Corner

Pittsburgh Lock

Not Required

Gage 24

751 - 900

26

Grooved Corner

Pittsburgh Lock

Not Required

901 - 1200

24

Grooved Corner

Pittsburgh Lock

Not Required

25x25x3mm

1201 - 1500

24

Grooved Corner

Pittsburgh Lock

Not Required

25x25x3mm

1501 - 1800

22

Grooved Corner

Pittsburgh Lock

Not Required

40x40x4mm

1801 - 2100

20

Grooved Corner

Pittsburgh Lock

Not Required

50x50x5mm

2101 - 2700

18

Pittsburgh Lock

Pittsburgh Lock

Not Required

50x50x5mm

2701 - 3000

18

Pittsburgh Lock

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

50x50x5mm

Gage 24
Gage 22
Gage 22 +
25X25X3 Angle

Table 1C : 1" W.G. Static Positive or Negative


(as per SMACNA Third Edition - 2005 Table 2-2)

Duct Dimension
(mm)

Gage

Intermediate
Reinforcement

Seam
Straight

Fittings

0 - 400

Grooved Corner

Pittsburgh Lock

401 - 750

Grooved Corner

Pittsburgh Lock

751 - 900

Grooved Corner

Pittsburgh Lock

901 - 1200

Grooved Corner

Pittsburgh Lock

1201 - 1500

Grooved Corner

Pittsburgh Lock

1501 - 1800

Grooved Corner

Pittsburgh Lock

1801 - 2100

Grooved Corner

Pittsburgh Lock

2101 - 2700

Pittsburgh Lock

Pittsburgh Lock

2701 - 3000

Pittsburgh Lock

Pittsburgh Lock

Gage 20

Transverse Connections

AS PER PROJECT SPECS.

1"

Slide-on
Flange

75

T-1
Drive Slip

T-3
Drive Slip with
Backup Angle

T-6
Hemmed S
Slip

T-10
Standing S
H. 28.6mm

T-13
Standing S
H. 41.3mm

T-14
Standing S
H. 54mm

T-22
Companion
Angles

Slide-on
Flange

* Materials Used for Transverse Connections :


- Galvanized Steel:(Standard)L.F.Q. Complying with ASTM A653 and Having G90 Coating Designation.
- Stainless Steel : (Optional) Complying with ASTM A240M / A480M, Grade 304, 304L, 316, & 316L.
* NOTE : 1 - Transverse Connectors are Based on 1200mm Spacing.
2 - Standard Straight Duct Length 1220mm.
3 - Companion Angle & Reinforcement are Made of Primer Painted Black Steel Angle.
18

Back to Index

I -Rectangular Ducts:
Ductwork Construction Schedule - Tables 2A / 2B / 2C - 2"
As per: - SMACNA (3rd Edition-2005 Table 2-3) See Page 2.18

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)

DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117


Transverse Connections

OPTION -1-

2"

Table 2A : 2" W.G. Static Positive or Negative


(as per SMACNA Third Edition - 2005 Table 2-3)

Duct Dimension
(mm)

Gage

Seam
Straight

Fittings

75

Intermediate
Reinforcement

T-1
Drive Slip

T-3
Drive Slip with
Backup Angle

T-6
Hemmed S
Slip

T-10
Standing S
H. 28.6mm

T-13
Standing S
H. 41.3mm

T-14
Standing S
H. 54mm

T-22
Companion
Angles

Slide-on
Flange

0 - 300

26

Grooved Corner

Pittsburgh Lock

Not Required

Gage 24

301 - 550

26

Grooved Corner

Pittsburgh Lock

Not Required

Gage 24

551 - 700

26

Grooved Corner

Pittsburgh Lock

Not Required

701 - 900

24

Grooved Corner

Pittsburgh Lock

Not Required

Flange 20
Thickness 0.7mm

901 - 1200

22

Grooved Corner

Pittsburgh Lock

Not Required

Flange 30
Thickness 0.8mm

1201 - 1500

20

Grooved Corner

Pittsburgh Lock

Not Required

Flange 30
Thickness 0.8mm

1501 - 2100

20

Grooved Corner

Pittsburgh Lock

Not Required

Flange 40
Thickness 1.0mm

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

Flange 40
Thickness 1.0mm

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

Flange 40
Thickness 1.0mm

2101 - 2700

18
18

2701 - 3000

Pittsburgh Lock
Pittsburgh Lock

Gage 24
Gage 22
Gage 22 +
25X25X3 Angle

Transverse Connections

OPTION -2-

2"

Table 2B : 2" W.G. Static Positive or Negative


(as per SMACNA Third Edition - 2005 Table 2-3)

Duct Dimension
(mm)

Gage

Seam
Straight

Fittings

Gage 20

75

Intermediate
Reinforcement

T-1
Drive Slip

T-3
Drive Slip with
Backup Angle

T-6
Hemmed S
Slip

T-10
Standing S
H. 28.6mm

T-13
Standing S
H. 41.3mm

T-14
Standing S
H. 54mm

T-22
Companion
Angles

0 - 300

26

Grooved Corner

Pittsburgh Lock

Not Required

Gage 24

301 - 550

26

Grooved Corner

Pittsburgh Lock

Not Required

Gage 24

551 - 700

26

Grooved Corner

Pittsburgh Lock

Not Required

701 - 900

24

Grooved Corner

Pittsburgh Lock

Not Required

25x25x3mm

901 - 1200

22

Grooved Corner

Pittsburgh Lock

Not Required

25x25x3mm

1201 - 1500

20

Grooved Corner

Pittsburgh Lock

Not Required

40x40x4mm

1501 - 2100

20

Grooved Corner

Pittsburgh Lock

Not Required

50x50x5mm

2101 - 2700

18

Pittsburgh Lock

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

50x50x5mm

2701 - 3000

18

Pittsburgh Lock

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

50x50x5mm

Gage 24
Gage 22
Gage 22 +
25X25X3 Angle

Table 2C : 2" W.G. Static Positive or Negative


(as per SMACNA Third Edition - 2005 Table 2-3)

Duct Dimension
(mm)

Gage

Intermediate
Reinforcement

Seam
Straight

Fittings

0 - 300

Grooved Corner

Pittsburgh Lock

301 - 550

Grooved Corner

Pittsburgh Lock

551 - 700

Grooved Corner

Pittsburgh Lock

701 - 900

Grooved Corner

Pittsburgh Lock

901 - 1200

Grooved Corner

Pittsburgh Lock

1201 - 1500

Grooved Corner

Pittsburgh Lock

1501 - 2100

Grooved Corner

Pittsburgh Lock

2101 - 2700

Pittsburgh Lock

Pittsburgh Lock

2701 - 3000

Pittsburgh Lock

Pittsburgh Lock

Gage 20

Transverse Connections

AS PER PROJECT SPECS.

2"

Slide-on
Flange

75

T-1
Drive Slip

T-3
Drive Slip with
Backup Angle

T-6
Hemmed S
Slip

T-10
Standing S
H. 28.6mm

T-13
Standing S
H. 41.3mm

T-14
Standing S
H. 54mm

T-22
Companion
Angles

Slide-on
Flange

* Materials Used for Transverse Connections :


- Galvanized Steel:(Standard)L.F.Q. Complying with ASTM A653 and Having G90 Coating Designation.
- Stainless Steel : (Optional) Complying with ASTM A240M / A480M, Grade 304, 304L, 316, & 316L.
* NOTE : 1 - Transverse Connectors are Based on 1200mm Spacing.
2 - Standard Straight Duct Length 1220mm.
3 - Companion Angle & Reinforcement are Made of Primer Painted Black Steel Angle.
19

Back to Index

I -Rectangular Ducts:
Ductwork Construction Schedule - Tables 3A / 3B / 3C - 3"
As per: - SMACNA (3rd Edition-2005 Table 2-4) See Page 2.20

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)

DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117


Transverse Connections

OPTION -1-

3"

Table 3A : 3" W.G. Static Positive or Negative


(as per SMACNA Third Edition - 2005 Table 2-4)

Duct Dimension
(mm)

Gage

Seam
Straight

Fittings

75

Intermediate
Reinforcement

T-1
Drive Slip

T-3
Drive Slip with
Backup Angle

T-6
Hemmed S
Slip

T-10
Standing S
H. 28.6mm

0 - 300

26

Grooved Corner

Pittsburgh Lock

Not Required

Gage 24

Gage 24

301- 450

26

Grooved Corner

Pittsburgh Lock

Not Required

Gage 24

Gage 22

T-13
Standing S
H. 41.3mm

T-14
Standing S
H. 54mm

T-22
Companion
Angles

Slide-on
Flange

451 - 750

24

Grooved Corner

Pittsburgh Lock

Not Required

Flange 20
Thickness 0.7mm

751 - 1000

22

Grooved Corner

Pittsburgh Lock

Not Required

Flange 30
Thickness 0.8mm

1001 - 1200

20

Grooved Corner

Pittsburgh Lock

Not Required

Flange 30
Thickness 0.8mm

1201 - 1500

18

Pittsburgh Lock

Pittsburgh Lock

Not Required

Flange 40
Thickness 1.0mm

1501 - 1800

18

Pittsburgh Lock

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

Flange 40
Thickness 1.0mm

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

Flange 40
Thickness 1.0mm

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

1801 - 2400

18
18

2401 - 3000

Pittsburgh Lock
Pittsburgh Lock

50x50x5mm

Transverse Connections

OPTION -2-

3"

Table 3B : 3" W.G. Static Positive or Negative


(as per SMACNA Third Edition - 2005 Table 2-4)

Duct Dimension
(mm)

Gage

Seam
Straight

Fittings

75

Intermediate
Reinforcement

T-1
Drive Slip

T-3
Drive Slip with
Backup Angle

T-6
Hemmed S
Slip

T-10
Standing S
H. 28.6mm

T-13
Standing S
H. 41.3mm

T-14
Standing S
H. 54mm

T-22
Companion
Angles

0 - 300

26

Grooved Corner

Pittsburgh Lock

Not Required

Gage 24

Gage 24

301- 450

26

Grooved Corner

Pittsburgh Lock

Not Required

Gage 24

Gage 22

451 - 750

24

Grooved Corner

Pittsburgh Lock

Not Required

25x25x3mm

751 - 1000

22

Grooved Corner

Pittsburgh Lock

Not Required

30x30x3mm

1001 - 1200

20

Grooved Corner

Pittsburgh Lock

Not Required

40x40x4mm

1201 - 1500

18

Pittsburgh Lock

Pittsburgh Lock

Not Required

50x50x5mm

1501 - 1800

18

Pittsburgh Lock

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

50x50x5mm

1801 - 2400

18

Pittsburgh Lock

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

50x50x5mm

2401 - 3000

18

Pittsburgh Lock

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

50x50x5mm

Transverse Connections

AS PER PROJECT SPECS.

3"

Table 3C : 3" W.G. Static Positive or Negative


(as per SMACNA Third Edition - 2005 Table 2-4)

Duct Dimension
(mm)

Gage

Intermediate
Reinforcement

Seam
Straight

Fittings

0 - 300

Grooved Corner

Pittsburgh Lock

301- 450

Grooved Corner

Pittsburgh Lock

451 - 750

Grooved Corner

Pittsburgh Lock

751 - 1000

Grooved Corner

Pittsburgh Lock

1001 - 1200

Grooved Corner

Pittsburgh Lock

1201 - 1500

Pittsburgh Lock

Pittsburgh Lock

1501 - 1800

Pittsburgh Lock

Pittsburgh Lock

1801 - 2400

Pittsburgh Lock

Pittsburgh Lock

2401 - 3000

Pittsburgh Lock

Pittsburgh Lock

Slide-on
Flange

75

T-1
Drive Slip

T-3
Drive Slip with
Backup Angle

T-6
Hemmed S
Slip

T-10
Standing S
H. 28.6mm

T-13
Standing S
H. 41.3mm

T-14
Standing S
H. 54mm

T-22
Companion
Angles

Slide-on
Flange

* Materials Used for Transverse Connections :


- Galvanized Steel:(Standard)L.F.Q. Complying with ASTM A653 and Having G90 Coating Designation.
- Stainless Steel : (Optional) Complying with ASTM A240M / A480M, Grade 304, 304L, 316, & 316L.
* NOTE : 1 - Transverse Connectors are Based on 1200mm Spacing.
2 - Standard Straight Duct Length 1220mm.
3 - Companion Angle & Reinforcement are Made of Primer Painted Black Steel Angle.
20

Back to Index

I -Rectangular Ducts:
Ductwork Construction Schedule - Tables 4A / 4B / 4C - 4"
As per: - SMACNA (3rd Edition-2005 Table 2-5) See Page 2.22

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)

DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117


Transverse Connections

OPTION -1-

4"

Table 4A : 4" W.G. Static Positive or Negative


(as per SMACNA Third Edition - 2005 Table 2-5)

Duct Dimension
(mm)

Gage

Seam
Straight

Fittings

75

Intermediate
Reinforcement

T-1
Drive Slip

T-3
Drive Slip with
Backup Angle

T-6
Hemmed S
Slip

T-10
Standing S
H. 28.6mm

T-13
Standing S
H. 41.3mm

T-14
Standing S
H. 54mm

T-22
Companion
Angles

Slide-on
Flange

0 - 250

26

Grooved Corner

Pittsburgh Lock

Not Required

Gage 24

Gage 24

251- 400

26

Grooved Corner

Pittsburgh Lock

Not Required

Gage 24

Gage 22

401 - 650

24

Grooved Corner

Pittsburgh Lock

Not Required

Flange 20
Thickness 0.7mm

651 - 900

22

Grooved Corner

Pittsburgh Lock

Not Required

Flange 30
Thickness 0.8mm

901 - 1000

20

Grooved Corner

Pittsburgh Lock

Not Required

Flange 30
Thickness 0.8mm

1001 - 1500

18

Pittsburgh Lock

Pittsburgh Lock

Not Required

Flange 40
Thickness 1.0mm

1501 - 2100

18

Pittsburgh Lock

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

Flange 40
Thickness 1.0mm
50x50x5mm
50x50x5mm

2101 - 2400

18

Pittsburgh Lock

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

2401 - 3000

18

Pittsburgh Lock

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

Transverse Connections

OPTION -2-

4"

Table 4B : 4" W.G. Static Positive or Negative


(as per SMACNA Third Edition - 2005 Table 2-5)

Duct Dimension
(mm)

Gage

Seam
Straight

Fittings

75

Intermediate
Reinforcement

T-1
Drive Slip

T-3
Drive Slip with
Backup Angle

T-6
Hemmed S
Slip

T-10
Standing S
H. 28.6mm

T-13
Standing S
H. 41.3mm

T-14
Standing S
H. 54mm

T-22
Companion
Angles

0 - 250

26

Grooved Corner

Pittsburgh Lock

Not Required

Gage 24

Gage 24

251- 400

26

Grooved Corner

Pittsburgh Lock

Not Required

Gage 24

Gage 22

401 - 650

24

Grooved Corner

Pittsburgh Lock

Not Required

25x25x3mm

651 - 900

22

Grooved Corner

Pittsburgh Lock

Not Required

30x30x3mm

901 - 1000

20

Grooved Corner

Pittsburgh Lock

Not Required

40x40x4mm

1001 - 1500

18

Pittsburgh Lock

Pittsburgh Lock

Not Required

50x50x5mm

1501 - 2100

18

Pittsburgh Lock

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

50x50x5mm

2101 - 2400

18

Pittsburgh Lock

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

50x50x5mm

2401 - 3000

18

Pittsburgh Lock

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

50x50x5mm

Transverse Connections

AS PER PROJECT SPECS.

4"

Table 4C : 4" W.G. Static Positive or Negative


(as per SMACNA Third Edition - 2005 Table 2-5)

Duct Dimension
(mm)

Gage

Intermediate
Reinforcement

Seam
Straight

Fittings

0 - 250

Grooved Corner

Pittsburgh Lock

251- 400

Grooved Corner

Pittsburgh Lock

401 - 650

Grooved Corner

Pittsburgh Lock

651 - 900

Grooved Corner

Pittsburgh Lock

901 - 1000

Grooved Corner

Pittsburgh Lock

1001 - 1500

Pittsburgh Lock

Pittsburgh Lock

1501 - 2100

Pittsburgh Lock

Pittsburgh Lock

2101 - 2400

Pittsburgh Lock

Pittsburgh Lock

2401 - 3000

Pittsburgh Lock

Pittsburgh Lock

Slide-on
Flange

75

T-1
Drive Slip

T-3
Drive Slip with
Backup Angle

T-6
Hemmed S
Slip

T-10
Standing S
H. 28.6mm

T-13
Standing S
H. 41.3mm

T-14
Standing S
H. 54mm

T-22
Companion
Angles

Slide-on
Flange

* Materials Used for Transverse Connections :


- Galvanized Steel:(Standard)L.F.Q. Complying with ASTM A653 and Having G90 Coating Designation.
- Stainless Steel : (Optional) Complying with ASTM A240M / A480M, Grade 304, 304L, 316, & 316L.
* NOTE : 1 - Transverse Connectors are Based on 1200mm Spacing.
2 - Standard Straight Duct Length 1220mm.
3 - Companion Angle & Reinforcement are Made of Primer Painted Black Steel Angle.
21

Back to Index

I -Rectangular Ducts:
Ductwork Construction Schedule - Tables 5A / 5B / 5C
- 500 Pa
As per: - DW/142 See Page 18
- DW/144 See Page 18

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)

DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

500 Pa

Transverse Connections

OPTION -1Table 5A : LOW PRESSURE 500 Pa


Positive as per DW/142-144 Table 2)

Duct Dimension
(mm)

Thick.
(mm)

Seam
Straight

Fittings

Intermediate
Reinforcement

C1
Drive Slip

C1
Drive Slip

C1
Hemmed S
Slip

C2
Standing S
H. 28.6mm

C3
Standing S
H. 28.6mm

C4
Standing S
H. 41.3mm

Companion
Angles

Slide-on
Flange

0 - 400

0.6

Grooved Corner

Pittsburgh Lock

Not Required

0.6mm

401 - 600

0.8

Grooved Corner

Pittsburgh Lock

Not Required

0.6mm

601 - 1000

0.8

Grooved Corner

Pittsburgh Lock

Not Required

1001 - 1250

1.0

Grooved Corner

Pittsburgh Lock

Not Required

Flange 30
Thickness 0.8mm

1.0

Grooved Corner

Pittsburgh Lock

Angle 30x30x3mm
@ 600mm

Flange 30
Thickness 0.8mm

1.0

Grooved Corner

Pittsburgh Lock

Angle 40x40x4mm
@ 600mm

Flange 40
Thickness 1.0mm

Grooved Corner

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

Flange 40
Thickness 1.0mm

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

Flange 40
Thickness 1.0mm

1251 - 1600
1601 - 2000
2001 - 2500

1.0

2501 - 3000

Pittsburgh Lock

1.2

500 Pa

0.6mm
0.6mm
0.8mm

0.8mm

Transverse Connections

OPTION -2Table 5B : LOW PRESSURE 500 Pa


Positive as per DW/142-144 Table 2)

Duct Dimension
(mm)

Thick.

Seam
Straight

Fittings

Intermediate
Reinforcement

C1
Drive Slip

C1
Drive Slip

C1
Hemmed S
Slip

C2
Standing S
H. 28.6mm

C3
Standing S
H. 28.6mm

C4
Standing S
H. 41.3mm

Companion
Angles

0 - 400

0.6

Grooved Corner

Pittsburgh Lock

Not Required

0.6mm

401 - 600

0.8

Grooved Corner

Pittsburgh Lock

Not Required

0.6mm

601 - 1000

0.8

Grooved Corner

Pittsburgh Lock

Not Required

1001 - 1250

1.0

Grooved Corner

Pittsburgh Lock

Not Required

25x25x3mm

1.0

Grooved Corner

Pittsburgh Lock

Angle 30x30x3mm
@ 600mm

30x30x3mm

1.0

Grooved Corner

Pittsburgh Lock

Angle 40x40x4mm
@ 600mm

40x40x4mm

Grooved Corner

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

40x40x4mm

Pittsburgh Lock

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

40x40x4mm

1251 - 1600
1601 - 2000
2001 - 2500

1.0

2501 - 3000

1.2

500 Pa

Slide-on
Flange

0.6mm
0.6mm
0.8mm

0.8mm

Transverse Connections

AS PER PROJECT SPECS.


Table 5C : LOW PRESSURE 500 Pa
Positive as per DW/142-144 Table 2)

Duct Dimension
(mm)

Thick.

Intermediate
Reinforcement

Seam
Straight

Fittings

0 - 400

Grooved Corner

Pittsburgh Lock

401 - 600

Grooved Corner

Pittsburgh Lock

601 - 1000

Grooved Corner

Pittsburgh Lock

1001 - 1250

Grooved Corner

Pittsburgh Lock

1251 - 1600

Grooved Corner

Pittsburgh Lock

1601 - 2000

Grooved Corner

Pittsburgh Lock

2001 - 2500

Grooved Corner

Pittsburgh Lock

2501 - 3000

Pittsburgh Lock

Pittsburgh Lock

C1
Drive Slip

C1
Drive Slip

C1
Hemmed S
Slip

C2
Standing S
H. 28.6mm

C3
Standing S
H. 28.6mm

C4
Standing S
H. 41.3mm

Companion
Angles

Slide-on
Flange

* Materials Used for Transverse Connections :


- Galvanized Steel:(Standard)L.F.Q. Complying with ASTM A653 and Having G90 Coating Designation.
- Stainless Steel : (Optional) Complying with ASTM A240M / A480M, Grade 304, 304L, 316, & 316L.
* NOTE : 1 - Transverse Connectors are Based on 1200mm Spacing.
2 - Standard Straight Duct Length 1220mm.
3 - Companion Angle & Reinforcement are Made of Primer Painted Black Steel Angle.
22

Back to Index

I -Rectangular Ducts:
Ductwork Construction Schedule - Tables 6A / 6B / 6C
- 1000 Pa
As per: - DW/142 See Page 19
- DW/144 See Page 19

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)

DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

1000 Pa

Transverse Connections

OPTION -1-

Table 6A : MEDIUM PRESSURE 1000 Pa


Positive as per DW/142-144 Table 3)
Duct Dimension
(mm)

Thick.

Seam
Straight

Fittings

Intermediate
Reinforcement

C1
Drive Slip

0.6mm

C1
Drive Slip

C1
Hemmed S
Slip

C2
Standing S
H. 28.6mm

C3
Standing S
H. 28.6mm

C4
Standing S
H. 41.3mm

Companion
Angles

Slide-on
Flange

0 - 400

0.6

Grooved Corner

Pittsburgh Lock

Not Required

401 - 600

0.8

Grooved Corner

Pittsburgh Lock

Not Required

601 - 800

0.8

Grooved Corner

Pittsburgh Lock

Not Required

Flange 20
Thickness 0.7mm

801 - 1000

0.8

Grooved Corner

Pittsburgh Lock

Not Required

Flange 30
Thickness 0.8mm

1.0

Grooved Corner

Pittsburgh Lock

Angle 40x40x4mm
@ 600mm

Flange 40
Thickness 1.0mm

1.0

Grooved Corner

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

Flange 40
Thickness 1.0mm

Pittsburgh Lock

Pittsburgh Lock

Angle 60x60x5mm
@ 600mm

1001 - 1600
1601 - 2500
2501 - 3000

1.2

1000 Pa

0.6mm
0.6mm

0.8mm

50x50x5mm

Transverse Connections

OPTION -2-

Table 6B : MEDIUM PRESSURE 1000 Pa


Positive as per DW/142-144 Table 3)
Duct Dimension
(mm)

Thick.

Seam
Straight

Fittings

Intermediate
Reinforcement

C1
Drive Slip

0.6mm

C1
Drive Slip

C1
Hemmed S
Slip

C2
Standing S
H. 28.6mm

C3
Standing S
H. 28.6mm

C4
Standing S
H. 41.3mm

Companion
Angles

0 - 400

0.6

Grooved Corner

Pittsburgh Lock

Not Required

401 - 600

0.8

Grooved Corner

Pittsburgh Lock

Not Required

601 - 800

0.8

Grooved Corner

Pittsburgh Lock

Not Required

25x25x3mm

801 - 1000

0.8

Grooved Corner

Pittsburgh Lock

Not Required

30x30x3mm

1.0

Grooved Corner

Pittsburgh Lock

Angle 40x40x4mm
@ 600mm

30x30x3mm

1.0

Grooved Corner

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

40x40x4mm

Pittsburgh Lock

Pittsburgh Lock

Angle 60x60x5mm
@ 600mm

50x50x5mm

1001 - 1600
1601 - 2500
2501 - 3000

1.2

Slide-on
Flange

0.6mm
0.6mm

1000 Pa AS PER PROJECT SPECS.

0.8mm

Transverse Connections

Table 6C : MEDIUM PRESSURE 1000 Pa


Positive as per DW/142-144 Table 3)
Duct Dimension
(mm)

Thick.

Intermediate
Reinforcement

Seam
Straight

Fittings

0 - 400

Grooved Corner

Pittsburgh Lock

401 - 600

Grooved Corner

Pittsburgh Lock

601 - 800

Grooved Corner

Pittsburgh Lock

801 - 1000

Grooved Corner

Pittsburgh Lock

1001 - 1600

Grooved Corner

Pittsburgh Lock

1601 - 2500

Grooved Corner

Pittsburgh Lock

2501 - 3000

Pittsburgh Lock

Pittsburgh Lock

C1
Drive Slip

C1
Drive Slip

C1
Hemmed S
Slip

C2
Standing S
H. 28.6mm

C3
Standing S
H. 28.6mm

C4
Standing S
H. 41.3mm

Companion
Angles

Slide-on
Flange

* Materials Used for Transverse Connections :


- Galvanized Steel:(Standard)L.F.Q. Complying with ASTM A653 and Having G90 Coating Designation.
- Stainless Steel : (Optional) Complying with ASTM A240M / A480M, Grade 304, 304L, 316, & 316L.
* NOTE : 1 - Transverse Connectors are Based on 1200mm Spacing.
2 - Standard Straight Duct Length 1220mm.
3 - Companion Angle & Reinforcement are Made of Primer Painted Black Steel Angle.
23

Back to Index

I -Rectangular Ducts:
Ductwork Construction Schedule - Tables 7A / 7B / 7C
- 2000 Pa
DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)

As per: - DW/144 See Page 19

DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

2000 Pa

Transverse Connections

OPTION -1-

Table 7A : HIGH PRESSURE 2000 Pa


Positive (as per DW/142-144 Table 4)
Duct Dimension
(mm)

Thick.

Intermediate
Reinforcement

Seam

C1
Drive Slip

C1
Drive Slip

Fittings

Straight

C1
Hemmed S
Slip

C2
Standing S
H. 28.6mm

C3
Standing S
H. 28.6mm

C4
Standing S
H. 41.3mm

Companion
Angles

Slide-on
Flange

0 - 600

0.8

Grooved Corner

Pittsburgh Lock

Not Required

Flange 20
Thickness 0.7mm

601 - 800

0.8

Grooved Corner

Pittsburgh Lock

Not Required

Flange 30
Thickness 0.8mm

801 - 1000

0.8

Grooved Corner

Pittsburgh Lock

Angle 30x30x3mm
@ 600mm

Flange 30
Thickness 0.8mm

1001 - 1250

1.0

Grooved Corner

Pittsburgh Lock

Angle 40x40x4mm
@ 600mm

Flange 40
Thickness 1.0mm

1.0

Grooved Corner

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

Flange 40
Thickness 1.0mm

1.2

Pittsburgh Lock

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

Flange 40
Thickness 1.0mm

1.2

Pittsburgh Lock

Pittsburgh Lock

Angle 60x60x5mm
@ 600mm

1251 - 1600
1601 - 2000
2001 - 2500

2000 Pa

50x50x5mm

Transverse Connections

OPTION -2-

Table 7B : HIGH PRESSURE 2000 Pa


Positive (as per DW/142-144 Table 4)
Duct Dimension
(mm)

Thick.

Intermediate
Reinforcement

Seam
Straight

Fittings

C1
Drive Slip

C1
Drive Slip

C1
Hemmed S
Slip

C2
Standing S
H. 28.6mm

C3
Standing S
H. 28.6mm

C4
Standing S
H. 41.3mm

Companion
Angles

0 - 600

0.8

Grooved Corner

Pittsburgh Lock

Not Required

25x25x3mm

601 - 800

0.8

Grooved Corner

Pittsburgh Lock

Not Required

25x25x3mm

801 - 1000

0.8

Grooved Corner

Pittsburgh Lock

Angle 30x30x3mm
@ 600mm

25x25x3mm

1001 - 1250

1.0

Grooved Corner

Pittsburgh Lock

Angle 40x40x4mm
@ 600mm

30x30x3mm

1.0

Grooved Corner

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

40x40x4mm

1.2

Pittsburgh Lock

Pittsburgh Lock

Angle 50x50x5mm
@ 600mm

40x40x4mm

1.2

Pittsburgh Lock

Pittsburgh Lock

Angle 60x60x5mm
@ 600mm

50x50x5mm

1251 - 1600
1601 - 2000
2001 - 2500

2000 Pa AS PER PROJECT SPECS.

Slide-on
Flange

Transverse Connections

Table 7C : HIGH PRESSURE 2000 Pa


Positive (as per DW/142-144 Table 4)
Duct Dimension
(mm)

Thick.

Intermediate
Reinforcement

Seam
Straight

Fittings

0 - 600

Grooved Corner

Pittsburgh Lock

601 - 800

Grooved Corner

Pittsburgh Lock

801 - 1000

Grooved Corner

Pittsburgh Lock

1001 - 1250

Grooved Corner

Pittsburgh Lock

1251 - 1600

Grooved Corner

Pittsburgh Lock

1601 - 2000

Pittsburgh Lock

Pittsburgh Lock

2001 - 2500

Pittsburgh Lock

Pittsburgh Lock

C1
Drive Slip

C1
Drive Slip

C1
Hemmed S
Slip

C2
Standing S
H. 28.6mm

C3
Standing S
H. 28.6mm

C4
Standing S
H. 41.3mm

Companion
Angles

Slide-on
Flange

* Materials Used for Transverse Connections :


- Galvanized Steel:(Standard)L.F.Q. Complying with ASTM A653 and Having G90 Coating Designation.
- Stainless Steel : (Optional) Complying with ASTM A240M / A480M, Grade 304, 304L, 316, & 316L.
* NOTE : 1 - Transverse Connectors are Based on 1200mm Spacing.
2 - Standard Straight Duct Length 1220mm.
3 - Companion Angle & Reinforcement are Made of Primer Painted Black Steel Angle.
24

Back to Index

II -Rectangular Ducts Welded


Longitudinal Seams & Connections
DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)
DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

Straight Ducts And Fittings With Flange Steel Angles

Flange Steel Angle


Semi-continuous Welding

Duct
Full Welded Seam

Continuous Welded

Flanged Cross Joint


Gasket or Sealant
Semi-continuous
Welding

Duct

Continuous Welded

Flange Steel Angles


Flange Steel Angle
Dimensions

Bolts Diam.

25x25x3mm

8mm

30x30x3mm

8mm

40x40x4mm

8mm

50x50x5mm

10mm

60x60x6mm

12mm

- Fixing Bolts at Each Corner Intermediately


Centered at 150mm.

* Materials Used for Ductworks & Connections :


- Carbon-Steel : Complying withASTM A 366/A 366M, Cold-rolled.
- Stainless Steel : (Optional) Complying with ASTM A240M / A480M, Grade 304, 304L, 316, & 316L.
* NOTES: Kitchen Ventilation Systems : - Access Doors for Cleaning Must be Provided at Distance not Exceeding 3 Metres.
As per: - DW 172 Page 36
- DW 144 Page 84

- Fire dampers must not be Used.


- Internal Thermal or Acoustic Lining Should not be Used, and Turning
Vanes Should be Avoided Wherever Possible.
25

Back to Index

II -Rectangular Ducts Welded


As per: - SMACNA (2nd Edition-1995) See Pages 2.3/2.9/A.42/A.43
- DW/144 See Pages 55/57

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)

DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

Straight

Taper

Standard Length 1220mm

22.5 Max.

OW

W1 x D1

W2 x D2

OD

WxD

L1

L1

Radius Bend

Master Bend

Outer R

OD

W2 x D2

Inner R

Minimum Throat Radius = 100mm


DVACStandard Throat Radius = 150mm

WxD

W1 x D1

Drop Cheek Bend

Trousers Piece

Can be Applied to any Angle


W2 x D2

W3 x D2

W2 x D2

OD
OW

W1 x D1

W1 x D1

* Materials Used for Ductworks & Connections :


- Carbon-Steel : Complying withASTM A 366/A 366M, Cold-rolled.
- Stainless Steel : (Optional) Complying with ASTM A240M / A480M, Grade 304, 304L, 316, & 316L.
* NOTES: Kitchen Ventilation Systems : - Access Doors for Cleaning Must be Provided at Distance not Exceeding 3 Metres.
As per: - DW 172 Page 36
- DW 144 Page 84

- Fire dampers must not be Used.


- Internal Thermal or Acoustic Lining Should not be Used, and Turning
Vanes Should be Avoided Wherever Possible.
26

Back to Index

II -Rectangular Ducts Welded


As per: - SMACNA (2nd Edition-1995) See Pages 2.8/2.9
- DW/144 See Pages 55/58

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)

DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

Angled Offset

Straight + 2 Branches
W2 x D2

Width (W) mm Dim. (A) mm


Up to 200

75

,,

300

100

,,

400

125

,,

600

150

Over 600

200

15 Max.

OW

WxD
W1 x D1

L1

A
L1

Radius 2-Way Offset

Straight + Branch

W3 x D3

Width (W) mm Dim. (A) mm


Up to 200
300

100

,,

400

125

,,

600

150

Over 600

200

OW

W1 x D1

W2 x D2

W1 x D1

W2 x D2

OD

L1

75

,,

L1

Mitered Offset

Radius Offset
Minimum Throat Radius = 100mm

30 Max.

OW

WxD

OW

W1 x D

E1
E2

W2
L1

L1

* Materials Used for Ductworks & Connections :


- Carbon-Steel : Complying withASTM A 366/A 366M, Cold-rolled.
- Stainless Steel : (Optional) Complying with ASTM A240M / A480M, Grade 304, 304L, 316, & 316L.
* NOTES: Kitchen Ventilation Systems : - Access Doors for Cleaning Must be Provided at Distance not Exceeding 3 Metres.
As per: - DW 172 Page 36
- DW 144 Page 84

- Fire dampers must not be Used.


- Internal Thermal or Acoustic Lining Should not be Used, and Turning
Vanes Should be Avoided Wherever Possible.
27

Back to Index

II -Rectangular Ducts Welded


As per: - SMACNA (2nd Edition-1995) See Page 2.7
- DW/144 See Pages 52/55

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)

DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

Breeches Piece

3-Way Tee
W3

W2

W4

W3
W2

R2

R2

R1

R1
W1 x D
W1 x D

Side Branch

2-Way Breeches
W2 x D2

W2

OD2
W3

W3 x D3

OD3

W1 x D1

W1 x D

Drop Cheek Breeches Piece

Access Door
Duct

Access Door
W2 x D2

OD2

W3 x D3

OD3

Bolt

R2

R1

W1 x D1

Ensure that Cleaning Doors are not on the


Underside of the Ductwork.

* Materials Used for Ductworks & Connections :


- Carbon-Steel : Complying withASTM A 366/A 366M, Cold-rolled.
- Stainless Steel : (Optional) Complying with ASTM A240M / A480M, Grade 304, 304L, 316, & 316L.
* NOTES: Kitchen Ventilation Systems : - Access Doors for Cleaning Must be Provided at Distance not Exceeding 3 Metres.
As per: - DW 172 Page 36
- DW 144 Page 84

- Fire dampers must not be Used.


- Internal Thermal or Acoustic Lining Should not be Used, and Turning
Vanes Should be Avoided Wherever Possible.
28

Back to Index

Rectangular Ducts
Tables: - Coating Mass (Weight)
- Galvanized Thicknesses
- Weight of Galvanized Steel

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.)

As per: - DW/144 See Pages 93/97/98

DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117

(Extract from BS.EN10142: 1991) Coating mass (Weight)


Minimum coating mass
(including both sides)

Coating Designation
Triple
spot test

Single
spot test

Suggested Applications
(Provided by British Steel PLC)

g/m

g/m

Zinc coatings (Z)


Z100
Z200

100
200

85
170

Light - for use where corrosion conditions are not


severe and/or where forming operations preclude
heavier coating.

Z275

275

235

Standard

Z350
Z450
Z600

350
450
600

300
385
510

Heavy Duty - for longer life relative to standard and


light coatings

Zinc-Iron alloy coatings (ZF)


ZF100
Zf180

100
180

85
150

Iron-zinc alloys- alloyed coating of iron and zinc


for easy painting and particularly resistance
welding.

Note 1. The mass of zinc is not always equally distributed on both surfaces of the sheet. However, it can
normally be expected that not less than 40% of the specified minimum coating mass, as determined by
the single spot test, will be found on each surface.

Galvanized Thicknesses

Weight of Galvanized Steel

Galvanized Steel *
Standard
Thickness

Birmingham
Gage

inch

mm

BG

inch

.0197
.0236
.0276
.0315
.0354
.0394
.0472

0.5
0.6
0.7
0.8
0.9
1.0
1.2

26
24

.0196
.0248

22

.0312

20
18

.0392
.0495

.0630
.0787
.0984

1.6
2.0
2.5

16
14
12

.0625
.0785
.0991

29

Thickness

Weight per
Square meter

mm
0.5
0.6
0.7
0.8
0.9
1.0
1.2
1.6
2.0
2.5

Kg
3.9213
4.7056
5.4898
6.2741
7.0584
7.8426
9.4111
12.5481
15.6852
19.6064

Back to Index

Remarks:

DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117


30

Back to Index

DVAC - DUCT VENTILATION AIR CONDITIONING Co. (W.L.L)


- Main Branch and Head Office
Industrial Area - Street 47 - Gate 6
Tel: +974 44500118 - 44500119 - Fax: +974 44500117

- 2nd Branch
Industrial Area - Street 46 - Gate 53
Tel: +974 44514381 - 44514188 - Fax: +974 44514052
Doha - State Of Qatar - P.O.Box: 55619
E-mail: info@dvac-duct.com - Web: www.dvac-duct.com

Back to Index

Back to Index

Você também pode gostar