Features:
Liberal enclosure: Ample wiring space is available for easy
termination.
Degree of Protection: IP54 enclosure makes it suitable for
use in almost all climatic conditions.
Ease of Maintenance: Contactor & Overload Relay mounted
on base plate, easily removable for maintenance if required.
User friendly: Contactor Coil & Contact housing can be
replaced with ease.
Range :
Direct on line starters 0.75HP - 100HP in four frame sizes
Automatic Star Delta Starters 10HP - 150HP in three
frame sizes
Reversing Starters 2HP - 20HP in single frame size
Direct On Line Submersible Pump Starter 5HP - 15HP
Automatic Star Delta Submersible Pump Starter 5HP 45HP
Specification :
Conforms to IS / IEC: 60947-4-1
61
Construction
Dol Starter - upto 100 HP
A DOL starter consists of contactor, overload relay, ON/OFF push buttons, housed in
a sheet steel enclosure.
DOL Starters are available in different ratings & sizes. The starter provides ample
space for wiring. Overload Relays are mounted on the Contactor which further results
in increased availability of space.
62
Features
Thermal bimetallic relay provides protection against overload, and single phasing Preventor gives protection against
Single Phasing.
Selectivity: Wide band operating Voltage 260V-415V AC (for use of Agricultural segment).
Robust Construction: Heavy Duty Contactor capable of working under severe conditions.
Easy to Check: Manual Trip Facility is provided to check the trip operation.
Flexible Design: Flexibility of onsite conversion between Automatic / Manual reset.
Better Safety for motor and Operator: Provision of MCB gives better protection against short circuit on ASD Premium Model.
Repeat accuracy: Electronic Timer is provided to precisely control the changeover from Star to Delta. The changeover time can
be set accurately from 1 to 30 seconds as per the motor requirement.
Added Safety from Flash-Over: A pause time has been provided between Star to Delta changeover to allow proper quenching
of arc. The pause timing is available from 30 to 150ms.
Option for Extended Protection: In case of momentary interruption in power supply the water in the pipes flowing backwards
into the ground. Sudden restoration of power supply during this period causes excessive load and may even result into burning
of the motor. To prevent this, starters can be made available with the option of protection of a built-in on-delay in the SPP unit.
Further, this delay can be provided optional as one minute or five minutes.
Three Mode Operation: Starter is provided with three modes of operation through a door mounted selector switch.
a. Auto mode with singhle-phasing preventor in circuit starts automatically.
b. In Manual mode the starter needs to be initialized manually through start button.
c. SPP Bypass In this SPP (including all protection provided therein) is bypassed. In this mode, the only protection available is
against overloading provided by overload relay.
Reliability:
Note: The on-delay in Single Phasing Preventor unit comes into effect only in auto mode.
63
Technical Information
64
Reference Standard
Type
Rated Operational Voltage
Rated Frequency
Utilization Category
Degree of Protection
Mounting
Cable entry
Earth Connection
Enclosure material
Type of Overload Relay
Relay reset
:
:
:
:
:
:
:
:
:
:
:
:
IS / IEC 60947-4-1
Air Break
415V AC
50Hz
AC3
IP 54
Wall / Surface
Top & Bottom
Diagonal (Top & Bottom)
CRCA Sheet Steel
Thermal Bimetallic
Auto-Manual / Manual
74.6
Type
CN1 12
CN1 12
CN1 12
CN1 12
CN1 12
CN2 18
CN2 18
CN4 32
CN4 32
CN5 40
CN5 50
CN5 65
CN6 80
CH6 95
CH1 115
CH1 150
Rating (A)
12
12
12
12
12
18
18
32
32
40
50
65
80
95
115
150
Type
RT11F
RT11G
RT11H
RT11J
RT11L
RT11M
RT11N
RT11P
RT22Q
RT13V
RT13W
RT13Y
RT23Z
ERT1 4D
ERT1 4D
ERT1 4D
Range (A)
1-1.6
1.6-2.5
2.5-4.0
4.0-6.0
7.0-10
10-13
13-18
18-25
23-32
30-40
38-50
57-66
63-80
80-93
90-150
90-150
Backup
Fuse
Rating (A)
4
6
10
16
20
25
25
50
50
63
80
100
125
125
160
160
143.6
CH1 150
150
ERT1 5E
132-220
200
Contactor
Overload Relay
Recommended Cable
Size Sq. mm.
Al.
Cu.
1.5
1
1.5
1
1.5
1
1.5
1
1.5
1
2.5
1.5
2.5
2.5
6
4
10
6
16
10
16
10
25
16
35
25
50
35
50
35
70
50
70
50
DOL
Standard ASD
Premium ASD
Amp. Meter
Volt. Meter
MCB
Light Indicator
65
Full Load
Current
(A)
Max.
Operational
Current
(A)
Contactor
Rating (A)
Overload
Relay Range
(A)
Recommended
Cable Size
Supply / Motor Side (Sq. mm)
HP
kW
AI
Cu
0.75
1.4
2.5
18
1.6-2.5
1.5
1.5
2.9
4.5
18
2.5-4
1.5
2.2
4.3
6.5
18
5.5-8
1.5
3.7
7.5
10.1
18
9-13
1.5
7.5
5.5
11
15.2
18
12-18
2.5
1.5
10
7.5
14
20.2
25
17-25
2.5
2.5
12.5
9.3
18
25.3
32
17-25
15
11
21.5
30.4
32
23-32
kW
Full
Load
Current
(A)
Max.
Operational
Current
(A)
(Recommended
Cable Size
Phase
Contactor
Overload
MCB
Current
(A)
Rating
Relay Range
Rating
Supply Side
(A)
(Sq. mm)
(A)
(A)
Motor Side
(Sq. mm)
AI
Cu
AI
Cu
3.7
7.5
10.13
5.85
18
5.5-8
25
1.5
1.5
1.5
1.0
7.5
5.5
11.25
15.19
8.77
18
7-10
25
2.5
2.5
1.5
1.5
10
7.5
15
20.25
11.69
18
9-13
25
2.5
2.5
1.5
1.5
12.5
9.3
18.75
25.31
14.61
18
12-18
32
2.5
1.5
1.5
15
11
22.5
30.38
17.54
25
17-25
32
2.5
2.5
17.5
13.1
26.25
35.44
20.46
32
17-25
40
10
2.5
20
15
30
40.5
23.38
32
17-25
50
10
2.5
22.5
16.8
33.75
45.56
26.31
32
23-32
63
16
10
25
19
37.5
50.63
29.23
32
23-32
63
16
10
27.5
20.5
41.25
55.69
32.15
40
30-40
100
16
10
30
22.4
45
60.75
35.08
50
30-40
100
16
10
35
26
52.5
70.88
40.92
50
37-50
100
25
16
10
40
30
60
81
46.77
65
37-50
100
35
25
16
10
45
33.6
67.5
91.13
52.61
80
48-65
125
35
25
16
10
Ordering Information
66
Contactor
Type
Rating (A)
CN1 12
12
CN1 12
12
CN1 12
12
CN1 12
12
CN1 12
12
CN2 18
18
CN2 18
18
CN4 32
32
CN4 32
32
CN5 40
40
CN5 50
50
CN5 65
65
CN6 80
80
CN6 95
95
CH1 115
115
CH1 150
150
CH1 150
150
Overload Relay
Type
RT11F
RT11G
RT11H
RT11J
RT11L
RT11M
RT11N
RT11P
RT22Q
RT12R
RT13V
RT13X
RT13Y
RT23Z
ERT1 4D
ERT1 4D
ERT1 5E
Range (A)
1-1.6
1.6-2.5
2.5-4
4-6
7-10
10-13
13-18
18-25
23-32
30-40
38-50
57-66
63-80
80-93
90-150
90-150
132-220
Motor Starter
Cat. No.
IHPDOLFA*
IHPDOLGA*
IHPDOLHA*
IHPDOLJA*
IHPDOLLA*
IHPDOLMB*
IHPDOLNB*
IHPDOLPD*
IHPDOLQD*
IHPDOLVE*
IHPDOLWE*
IHPDOLYF*
IHPDOLZF*
IHPDOLDG*
IHPDOLDG*A
IHPDOLDG*B
IHPDOLEH*
Contactor
Type
Rating (A)
CN2 18
18
CN2 18
18
CN3 25
25
CN3 25
25
CN4 32
32
CN4 32
32
CN4 32
32
CN5 50
50
CN5 50
50
CN5 65
65
CN6 80
80
CN6 95
95
CH1 115
115
CH1 150
150
Overload Relay
Type
RT21M
RT21N
RT21N
RT21P
RT21P
RT22Q
RT22R
RT23V
RT23W
RT23X
RT23Y
RT23Z
ERT1 4D
ERT1 4D
Range (A)
9-13
12-18
12-18
17-25
17-25
23-32
28-36
37-50
48-65
55-70
63-80
80-93
90-150
90-150
Motor Starter
Cat. No.
IHPASDMB*
IHPASDNB*
IHPASDNC*
IHPASDPD*
IHPASDQD*
IHPASDQD*A
IHPASDUE*
IHPASDWE*
IHPASDWF*
IHPASDYF*
IHPASDCG*
IHPASDDG*
IHPASDDG*A
IHPASDEH*
* To complete Cat No., suffix voltage code from coil voltage table.
Reversing Starters
Motor Rating 415V,
3-Phase, 50Hz
HP
kW
2
1.5
3
2.2
5
3.7
7.5
5.6
10
7.5
15
11.2
20
14.9
Contactor
Type
CN1 12
CN1 12
CN1 12
CN2 18
CN2 18
CN4 32
CN4 32
Rating (A)
18
18
18
18
18
32
32
* To complete Cat No., suffix voltage code from coil voltage table.
Reversing Starter
Overload Relay
Type
RT11H
RT11J
RT11L
RT11M
RT11N
RT11P
RT22R
Range (A)
2.5-4
4-6
7-10
10-13
13-18
18-25
28-36
Motor
Starter
Cat. No.
IHPREVHB*
IHPREVJB*
IHPREVLB*
IHPREVMB*
IHPREVNB*
IHPREVPD*
IHPREVRD*
Ordering Information
kW
Contactor
Rating (A)
Overload
Relay Range (A)
Cat. No.
3.7
18
9-13
IHSDOAMBW
7.5
5.5
18
12-18
IHSDOANBW
10
7.5
25
17-25
IHSDOAPCW
12.5
9.3
32
17-25
IHSDOAPDW
15
11
32
23-32
IHSDOAQDW
kW
Contactor
Rating (A)
Overload
Relay Range (A)
Cat. No.
IHSASAKBW
3.7
18
5.5-8
7.5
5.5
18
7-10
IHSASALBW
10
7.5
18
09-13
IHSASAMBW
12.5
9.3
18
12-18
IHSASANBW
15
11
25
17-25
IHSASAPCW
17.5
13.1
32
17-25
IHSASAPDW
20
15
32
17-25
IHSASAPDWA
22.5
16.8
32
23-32
IHSASAQDW
25
19
32
23-32
IHSASAQDWA
27.5
20.5
40
30-40
IHSASAUEW
30
22.4
50
30-40
IHSASAUEWA
35
26.1
50
37-50
IHSASAVEW
40
29.8
65
37-50
IHSASAVEWA
45
33.6
80
48-65
IHSASAWFW
HP
kW
Contactor
Rating (A)
Overload
Relay Range (A)
TP MCB
Rating (A)
Cat. No.
3.7
18
5.5-8
25
IHDASAKBW
7.5
5.5
18
7-10
25
IHDASALBW
10
7.5
18
09-13
25
IHDASAMBW
12.5
9.3
18
12-18
32
IHDASANBW
15
11
25
17-25
32
IHDASAPCW
17.5
13.1
32
17-25
40
IHDASAPDW
20
15
32
17-25
50
IHDASAPDWA
22.5
16.8
32
23-32
63
IHDASAQDW
25
19
32
23-32
63
IHDASAQDWA
27.5
20.5
40
30-40
100
IHDASAUEW
30
22.4
50
30-40
100
IHDASAUEWA
35
26.1
50
37-50
100
IHDASAVEW
40
29.8
65
37-50
100
IHDASAVEWA
45
33.6
80
48-65
125
IHDASAWFW
67
151
156
68
4-
A
B
130
4-
6 Mounting Holes
E
F
M4 x 2 Earthing Hole
(Top & Bottom)
20 x 4 Holes
(Top & Bottom)
Frame
Size
HP
Rating
0.75 to 5
185
135
7.5 to 20
223
190
105
60
139
135
43
25
30
143
105
154
149
44
24
54
270
280
320
D
C
40
220
260
240.6
75
229.6
58
87.5
200
73.5
2 - M6 EARTHING HOLES
ON EITHER SIDES
275
58
87.5
130
58
370
350
452.4
51.2
4- 8.5 ENCLOSURE
WALL MOUNTING HOLES
L2
L3
K1
R1
S1
S2
S1
A1
A2
K1
13
14
= Contactor
= Overload Relay
= Start Push Button
= Stop/Reset Push Button
S2
97
95
98
96
69
REV
START
1
2
3
4
5
6
13
14
A1 A2
REVERSE
61
53
62
54
FOR
START
L3 L2 L1 C2 B2 A2
INCOMING
M
3
MOTOR
13
14
A1 A2
61
53
FORWARD
62
54
STOP
95
97
96
98
40
220
260
107
270
280
320
62.2
209
92.2
60
199.2
110
230
95
430
300
73.5
450
250.4
97.4
261.4
522.4
25
210
400
670
750
882.5
25
40
40
75
HAVELLS
75
70
156
SCALE 3:10
HAVELLS LOGO (0.5MM EMBOSSED INSIDE)
580
71
53
61
21
13
54
62
22
14
21
4
22
14
21
13
22
14
72
50Hz, Supply
L1 L2 L3
P1
R
V1
Y
V2
B
A1 P2
A
A2
V1
V2
2 STOP
97 98 51 H5 52
R1
A (MOTOR TRIP)
R NO
Y COM
B T1
T2
SPP
P.B(S1)
START
P.B(S2)
K1
14
A
3
M
1
2
M
4
A
6
A2
K1
A1
41
G MOTOR ON
42
K1
95
96
R1
R1
A2 B2 C2
70
46
86.85
170.7
142
49.5
3 - 50
222.7
105
113.2
66
190.6
402.4
194.1
554.8
379.8
238
328.4
271.6
162
399.2
436.2
451.6
11
21
H1
12
L2
L3
P1
R V1
Y V2
B
31
V1
V2
VSS
H2 H3
R
22
32
A1 P2
2 STOP
START
P.B(S2)
1 P.B(S1)
A2
R
Y
B
53
K1
54
NO
COM
T1
T2
97
H5
98 51
R1
SPP
52
13
13
K1
14
K3
14
SS1
3
K1
K2
4
K3
4
A1
3
M
SPP (B)
B2
A2
C2
D1 15
D1
B2 C2
A1
B1
A2
95
96
R1
MOTOR ON
42
62
K3
K3
12
C1
41
H4
61
K2
A2
TIMER
A1
11
R1
A2
D1 25
A1
STAR
A2
A2
K2
K1
A1
A1
DELTA
MAIN
86.85
170.7
131.85
142
49.5
3 - 50
113.2
70
46
222.7
105
66
190.6
402.4
194.1
554.8
379.8
238
328.4
271.6
162
399.2
436.2
451.6
74
11
21
H1
H2 H3
12
22
L2
L3
31
32
P1
R V1
Y V2
B
VSS
MCB
V1
V2
A1 P2
2 STOP
START
P.B(S2)
1 P.B(S1)
A2
R
Y
B
53
K1
54
NO
COM
T1
T2
97
H5
98 51
R1
SPP
52
13
13
K1
14
K3
14
SS1
3
K1
K2
2
1
A
K3
2
A1
3
M
C2
SPP (B)
B2
A2
D1
A1
B1
61
K3
96
R1
62
A2
95
41
H4
K3
12
C1
TIMER
A1
K2
B2 C2
A2
D1 25
11
R1
A2
D1 15
A1
STAR
A2
A2
K2
K1
A1
DELTA
A1
MAIN
Nameplate
ON / OFF Push Buttons
Sheet Steel Enclosure
Cover screws with screw retainer
Cable Entry
Earthing
Screw
Star
Contactor
Main Contactor
Delta
Contactor
Timer
Thermal
Overload Relay
Base Plate
Cable Entry
MOTOR ON
42
Phase Indicator
Pump ON Indicator
Pump Trip Indicator
Earthing Screw
Voltmeter
Ammeter
MCB
Stop Push Button
Start Push Button
Main Contactor
Delta Contactor
Timer
Single Phase Preventor
Star Contactor
Overload Relay
Base Plate
Outgoing Terminals
for Motor
75