Escolar Documentos
Profissional Documentos
Cultura Documentos
P E R RY E Q U I P M E N T C O R P O R AT I O N
ISO 9001
S E R I E S 85, 88, 90
SMALL VOLUME
GAS FILTERS & FILTER/SEPARATORS
E N G I N E E R E D
F I LT R AT I O N
S O L U T I O N S
45
45
INLET
OUTLET
HSLD
Vent
4-13/16"
Diameter Holes
45
45
45
OUTLET
HSLD
Vent
4-13/16"
Diameter Holes
Guage Glass
Pressure Guage
Vent 1/2"
CPLG
45
INLET
Guage Glass
Pressure Guage
Vent 1/2"
CPLG
GA.GL.
1/2" CPLG
Vent 1"
CPLG (F.S.)
INLET
Vent 1"
CPLG (F.S.)
12"
GA.GL.
1/2" CPLG
INLET
GA.GL.
1/2" CPLG
Drain 1"
CPLG (F.S.)
OUTLET
PR.GA.
1/2" CPLG
12"
Vent 1"
CPLG (F.S.)
12"
85
B
C
HSLD 1"
CPLG
2"
O.D.
2"
E
BOLT CIRCLE
CPLG
GA.GL. 12"
1/2" CPLG
2"
5"
Drain 1"
CPLG (F.S.)
Gasket __________________Buna-N
Vent 1"
CPLG (F.S.)
GA.GL. 12"
1/2" CPLG
Drain 1"
CPLG (F.S.)
OUTLET
O.D.
A
PR.GA.
1/2" CPLG
E
BOLT CIRCLE
Drain 1"
CPLG (F.S.)
SERIES 85 DIMENSIONS
Model
85-1-PCHG12
85-1-PCHG24
85-1-PCHG36
85-2-PCHG36
85-3-PCHG36
Notes:
O.D
6 5/8
6 5/8
6 5/8
8 5/8
10 3/4
A
54 3/4
69 3/4
78 3/4
85 3/4
92 1/8
B
44 1/2
44 1/2
44 1/2
51 1/2
56 1/2
C
24
24
24
30
33
D
36 1/8
39 1/8
36 1/8
43 1/8
48 1/8
E
9 1/8
9 1/8
9 1/8
11 1/8
13 1/4
F
9 1/4
9 1/4
9 1/4
10 1/4
11 3/8
15
18
H
14
26
38
38
38
1. Changes to standard units, including different inlet and outlet sizes, inspection opening, or special connections can be furnished at
slight additional cost. Consult factory for price and delivery.
2. Filters are of welded construction for a safe working pressure of 275 P.S.I. at 100 F and are ASME, Div. 1, Section VIII code stamped.
3. All dimensions are in inches.
4. Models with 1/8 corrosion allowance are available.
0
Drain
45
315
Equalizer
OUTLET
INLET
270
GA.GL.
HSLD
Vent
NPT
GA.
GL. Drain HSLD Equalizer A
1
1
1
82 3/4
1
1
1
1
86 3/4
1
1
1
1
96 1/8
1
B
47 1/2
54 1/2
59 1/2
C
27
33
36
135
Vent
Equalizer
85
INLET
D
39 1/4
42 3/8
48 1/4
E
5
5
5
GA.GL.
O.D.Dia.
GA.GL.
OFFSHORE
225
Element Removal
J Required for
is designed
specifically for the offshore industry to remove
liquid and solid contaminant particles, such as
hydrocarbon liquids, dirt, rust and pipeline scale
from natural gas fuel in low flow applications. Units
feature flanged connections, blind flange closures
and 3-coat marine paint systems.
PR.GA
F
9 1/8
11 1/8
13 1/4
Drain
PR.GA.
B
H
G
9 1/4 9 1/4
10 1/4 15
11 3/8 18
J
38
38
38
PR.GA.
OUTLET
Equalizer
HL.SD.
GA.GL.
HL.SD.
GA.GL.
E
2"
F
Drain
90
The Series 90
45
45
Vent
4-13/16"
Diameter Holes
E
9 1/8
9 1/8
9 1/8
11 1/8
13 1/4
F
9 1/4
9 1/4
9 1/4
10 1/4
11 3/8
G
14
26
38
38
38
1
1
1
2
3
H
5/8
5/8
5/8
3/8
5/8
O.D.
C O N V E R S I O N
INLET
Required for
Swing Bolt
Anchor
Bolt Lug
OUTLET
2"
Drain 1"
CPLG (F.S.)
C H A R T
36
36
HG
HG
-PC
90-3
30
-PC
40
HG
50
36
100
90
80
70
60
851-P
CH
901-P G24
CH
G1
852
1-P
CH
G3
6
901-P
CH
G24
901-P
CH
G36
852-P
CH
G3
6
200
85-3
D
3/4
3/4
3/4
3/4
3/4
7
7
7
7
7
-PC
C
4
4
4
4
4 5/8
B
15 3/4
15 3/4
15 3/4
15 3/4
15 3/4
OUTLET
Pressure Guage
90-2
A
26
41
50
50
50 3/4
851-P
CH
G1
2
Notes:
O.D
6 5/8
6 5/8
6 5/8
8 5/8
10 3/4
INLET
90
SERIES 90 DIMENSIONS
Model
90-1-PCHG12
90-1-PCHG24
90-1-PCHG36
90-2-PCHG36
90-3-PCHG36
Drains
45
45
Element Removal
20
10
200,000
100,000
90,000
80,000
70,000
60,000
50,000
40,000
30,000
20,000
10,000
9,000
8,000
7,000
6,000
4,000
5,000
3,000
2,000
1,000
1.50
MAXIMUM FLOW RATE (SCFH of 0.65 SP. GR. at 14.7 PSIA and 60 F)
1.40
1.00
1.20
.90
.80
1.10
.70
1.00
.60
.90
.50
40
80
120
160
200
GAS FLOWING TEMPERATURES, F
240
280
.80
CORRECTION FACTORS
1.30
1. If vapor phase is other than natural gas of 0.65 specific gravity at 60 F and
14.7 PSIA, correct to these conditions using the PECO Conversion Chart on
top left hand corner of this sheet as follows:
Find the maximum operating temperature on the horizontal scale.
Follow temperature line vertically until it intersects with the specific
gravity line. The correction factor is then found horizontally to the right
of the intersection.
2. Multiply the flow rate (SCFH) by the correction factor.
3. Determine PECO Filter-Sep or Filter required by entering sizing chart at left at
minimum operating pressure. Move to right to intersection with the corrected
maximum gas flow line.The PECO Filter-Sep or Filter required is shown by the
slanted line to the right of the intersection of the operating pressure and
corrected maximum gas flow lines.The Sizing is based upon a maximum
pressure drop of 60 water column across the entire unit.
8 1/2"
Element Removal
6 1/4"
The Series 88
Gruva Grip
Closure
4 1/2"
19 3/8"
SERIES 88
MATERIALS OF CONSTRUCTION
Element
3/4" 3000#
CPLG Outlet
88
4 7/8"
3/4" 3000# CPLG
Inlet
20,000
10
9
8
7
6
88 Conversion Chart
1.50
5
4
1.40
1.30
10
7 8 9 100
6 700
1.00
1.20
.90
.80
1.10
CORRECTION FACTORS
1000
.70
1.00
.60
.90
.50
40
80
120
160
200
GAS FLOWING TEMPERATURES, F
240
280
.80
Please refer to www.perryequipment.com for your most current literature edition and address information.