Você está na página 1de 14

Stage and Studio Lamps

QUARTZLINE TUNGSTEN HALOGEN ....................................... 6-7


QUARTZLINE TUNGSTEN HALOGEN HIGH VOLTAGE .......... 6-8
CINEMA LAMPS
Fluorescent Lamps ................................................................................... 6-9
Fluorescent covRguard Lamps ............................................................. 6-9
Fluorescent Biax ................................................................................... 6-10

CSR METAL HALIDE LAMPS


Single-Ended Cold Start ........................................................................ 6-10
Single-Ended Short Arc ......................................................................... 6-10
Single-Ended Hot Restrike .................................................................... 6-10
Double-Ended Hot Restrike .................................................................. 6-10

ANSI CODES .................................................................................. 6-11


For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose
the one with the lowest watts. All footnote references found at the end of this section.
Reduced Wattage High Color Rendering

06-StageAndStudio 2003.09

01/23/04, 11:54 AM

6-1

Stage and Studio Lamps

BULB IDENTIFICATION
DIA.

DIA.

MOL
MOL

LCL

DIA: Diameter of bulb at widest point.


MOL: Maximum Overall Length including
base or pins.
LCL: Distance between the center of the
arc tube and the Light Center Length
reference plane.
Note: Lamp drawings are not drawn to
scale. Be sure to check size and dimension
information when identifying each lamp.
To convert inches to millimeters, multiply
the dimension (in inches) by 25.4
(i.e. inches x 25.4 = millimeters).

LAMP LOCATOR

T12
G13

T8
G13
T12
Med Pf

T14
Med 2-Pin (G9.5)
Biax
2G11

Incandescent Lamps

Fluorescent Cinema Lamps

T3, T5
R7s

T4
R7s

T6
R7s

PAR36
Ferrule

G6, G7
2-Pin Prefocus
(GX9.5 / GY9.5)

PAR36
Scrw Term

PAR64
Extended Mog End
Prefocus

PS52
Mog (E39)

T4, T6
T4, T6, T7, T8
Med 2-Pin Med Prefocus
(G9.5)
(P28s)

T4
T6
T6
T5
Mini-Cand 2-Pin Prefocus Med 2-Pin Special
(G9.5)
(GX9.5 / GY9.5)

Quartzline Tungsten Halogen

6-2
06-StageAndStudio 2003.09

For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose
the one with the lowest watts. All footnote references found at the end of this section.
Reduced Wattage High Color Rendering

01/23/04, 11:54 AM

T7, T8, T10


Mog Prefocus
(P40s)

Stage and Studio Lamps

T7
T7
Med 2-Pin Med BiPost
(G9.5)
(G22)

T20
Mog BiPost
(G38)

T26
GX38

T24
Mog BiPost
(G38)

T32
GX38

T7
T8
Mog BiPost 2-Pin Prefocus
(G38)
(GX9.5)

T7, T8
Med BiPost
(G22)

T8
GX9.5

T8
Med 2-Pin
(G9.5)

T8
Mog (E39)

T8, T10
Mog BiPost
(G38)

T12
Med Prefocus
(P28s)

Quartzline Tungsten Halogen (Continued)


T4.5
X515

T6.5
SFc10-4

T9
SFc10.5-6

G7
GY9.5
Short Arc Discharge

T9, T12
SFa 21-12

T16, T22.5
25x51 Cyl
165mm Lead

T5, T6
GZX9.5,
GZY9.5

T9.5
G22

T13
G38

T24
G38

T32
G38

T28
30x70 Cyl
165mm Lead
Double-Ended Hot Restrike

Single-Ended Hot Restrike

CSR Metal Halide Lamps


For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose
the one with the lowest watts. All footnote references found at the end of this section.
Reduced Wattage High Color Rendering

06-StageAndStudio 2003.09

01/23/04, 11:54 AM

6-3

Stage and Studio Lamps

LAMP LOCATOR (CONTINUED)

PAR64
Extended Mog End
Prefocus

T6
T6, T8
T8
T8
T8
T10
T8
T10, T11
T6
Med 2-Pin Med Prefocus Special 2-Pin Prefocus 2-Pin Prefocus Med BiPost Med Prefocus 2-Pin Prefocus Mog BiPost
(G9.5)
(P28s)
(GX9.5)
(GX9.5)
(P28s)
(G38)
(G22)
(GX9.5)

T3
R7s

T11
GY9.5

Quartzline Tungsten Halogen High Voltage

FILAMENT IDENTIFICATION

2C8
2CC-8

C-2V
CC-2V

C-5

C-6
CC-6

C-7A

CC-8

C-9

C-13

C-13D

BASE IDENTIFICATION

Can DC Bay

2-Pin (Round)
GX5.3

GX9.5

GY9.5

2-Pin Pf Min BiPin


GY16
G5.3

G9.5

Mini Cand
Recessed
E11
Single Contact
R7s
SFa 21-12 SFc 10-4 SFc 10.5-6 X515

Ferrule

Screw
Terminal

Med Pf
P28s

Med Side Pr

Cylinder

Mog Pf
P40s

Ext. Mog End Pr


GX16d

6-4
06-StageAndStudio 2003.09

Med Screw
E26

Mog End Pr
GX16d

Med BiPost
G22

Mogul BiPost
G38

Special

For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose
the one with the lowest watts. All footnote references found at the end of this section.
Reduced Wattage High Color Rendering

01/23/04, 11:54 AM

Mog Screw
E39

Stage and Studio Lamps


INTRODUCTION
GE Lighting has been a leading supplier to stage and studio users for
many decades, and continues its pioneering work in the development
of new and innovative light sources.
The primary change in recent years has been the migration from glass to
quartz as the standard bulb material. The higher melting point of quartz
enables bulb envelopes to be reduced in size and the halogen fillings to
be run at higher pressures, leading to smaller, lighter, brighter, more
energy-efficient and more reliable lamps.
GE Lightings comprehensive range of single- and double-ended lamps
is complemented by a group of PAR lamps, where the light source is
enclosed in a sealed reflector unit.

The beam patterns of PAR lamps range from very narrow spot to wide-angle
floods. This ensures consistency from lamp to lamp, interchangeability to
suit the beam pattern needs of the moment and instant replaceability
without the need to refocus and re-aim fixtures.
The sealed beam design prolongs the life of the inner lamp as well as
protecting it from dust, vapor and other hazards, thereby ensuring high
lumen maintenance over the life of the lamp.
PAR lamps may be used with very simple, lightweight, economical fixtures.

GENERAL INFORMATION
OPERATIONAL CHARACTERISTICS
Quartz halogen lamps are designed to be operated within close voltage
tolerances, and excessive voltage can lead to drastically shortened life,
albeit with significantly higher light output.
A second important variable is temperature. The tungsten halogen cycle
does not operate properly below about 482F (250C) and quartz may
begin to devitrify above about 1832F (1000C). Bulb envelopes should
therefore be held in the range 482-1472F (250-800C).
The contact pins are plated to ensure good electrical connection with
the lampholder. However, at temperatures above 350C, the plating may
lose adhesion, leading to deterioration in contact and possibly local hot
spots, arcing and consequent irreparable damage to both lamp and
holder. Note that if there is evidence that this has occurred, the lampholder
should be replaced before the next lamp is fitted, otherwise it is likely to
fail prematurely for the same reason.
Lamps normally fail by fusing of the filament. This is often followed by
arcing, leading to very high currents which can cause the envelope and
seals to fail and the lamp to shatter. A quick-acting, high-breaking
capacity fuse should therefore be connected to the supply line in all
applications. Suitable types are given in IEC 127, 241 and 269.

CHROMISE SEAL PROTECTION


Many Quartzline Stage/Studio lamps have a special chromised seal
protection, which allows lamp seal temperatures up to 500 C (vs
traditional 350 C), which increases life and reliability. Look for this
seal on the package coming soon.

If the package does not have this seal, lamp base temperatures for
Quartzline lamps should not exceed 350C because, above that point,
lead wires in the sealing area will deteriorate, and base cement can
loosen, both causing premature lamp failure. Note overvoltaging a lamp
will increase the seal heat.

LAMP CODES
GE Stage & Studio lamps are coded as such:
Lamp Description. This may be either an American National Standards
Institute (ANSI) three letter code such as EJG, or a descriptive code in
the general form Q750T3/4CL. ANSI codes are assigned to lamp
specifications mechanical, electrical and photometric characteristics
filed with the Institute.
They ensure interchangeability among similarly coded lamps from
different manufacturers. Most of these lamps are rated for 120-volt
operation. In a few cases a pair of ANSI codes are given (e.g. BFL/BFK),
where the first is the official code for the lamp and the second code
describes lamps the specifications of which are met or exceeded. In such
cases, the lamps may be used to replace lamps with either code.
Base designations conform to IEC standards.

PRODUCT INFORMATION
GE CSR/CSD METAL HALIDE LAMPS
New GE range of metal halide lamps for use in a variety of applications
including TV and film, stage, concerts, photographic and large screen
presentation and color simulation.
Excellent color rendering Ra >90
Daylight color temperature, typically 6000K
Universal burning position
High efficiency up to 100 Lm/Watt
Hot restrike and dimmable with stable color temperature
Superior color stability
Excellent lumen maintenance
Use with electronic or AC magnetic ballast/ignitor control gear
Applications include inside and outside TV and film production, stage,
concerts, sporting events, photographic studios, overhead and large
screen projection and color simulation.

GE CINEMA FLUORESCENT LAMPS


High CRI (Color Rendering Index) traditional fluorescent lamps have not
been widely used in photography and film making because of relatively low
CRI and the prominent green spike found in typical fluorescent phosphors.
GE Lighting Cinema 32 and Cinema 55 lamps have corrected these deficiencies
with products that now have a CRI of 95 (out of 100 max.) and colors that
respond to the spectral sensitivity curves of film and electronic imaging media.
Optional Shatter Resistance GE Cinema 32 and 55 offer the option of
GEs exclusive covRguard shatter resistance that helps contain glass
fragments if the lamps are broken. Reduce the possibility of glass related
injuries to irreplaceable talent, damage to expensive sets, contamination of
delicate equipment or missing critical deadlines because GE offers complete
shatter resistance. GEs covRguard process wraps the Cinema lamps in a full
15 ml thick casing of GEs exclusive Lexan polycarbonate that helps
contain the glass, phosphor and chemicals if the lamp is broken. Unlike
other shatter-resistant lamps, GEs covRguard lamps require no assembly.

For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose
the one with the lowest watts. All footnote references found at the end of this section.
Reduced Wattage High Color Rendering

06-StageAndStudio 2003.09

01/23/04, 11:54 AM

6-5

Stage and Studio Lamps

PRODUCT INFORMATION (CONTINUED)


Superior Light Output the GE covRguard process offers maximum
protection with minimal light loss the lowest loss of initial light of other
shielded products.
Dependable UV Blocking the GE covRguard process also offers excellent
UV blocking. CovRguard blocks 98% of the UV that is normally transmitted
from an unprotected fluorescent lamp all UVC, all UVB and most of
UVA. This is critical for protecting expensive sets and wardrobe from the
fading effects of UV exposure.

Chromaticity the Cinema 32 has a chromaticity of X=.415 and Y=.377 with


a CRI of 95. The Cinema 32 mixes well with both incandescent and quartz
halogen light sources without color corrections. The Cinema 55 is a broad
band spectrum daylight lamp with a chromaticity of X=.325 and Y=.321 and
a CRI of 96. The Cinema 55 mixes well with ambient daylight and short arc
discharge HID light sources without color corrections.
For more detailed information on all GE Stage and Studio lighting order
Showbiz 2004, PC 23766 from your GE sales representative.

HEADINGS IN THIS CATALOG SECTION


The following terms and descriptions can help you when checking
Stage/Studio lamp specifications and when ordering products. Within
each product line, lamps are divided into families, within these
families, lamps are then listed by wattage.
Approximate CBCP (Center Beam Candlepower):
Volts:

Case Quantity:

Lamp data is based on


operation at rated voltage.

Number of product units


packed in a case.

For reflector type lamps. Center Beam Candlepower is the intensity


(candelas) at the center or maximum intensity of the beam.

Color Temperature - Kelvins (K):


A measure of the visual warmth or coolness of the light from the
lamp. The higher the value, the whiter or cooler the light appears.

Order Code:
It is important to use this five-digit code
when ordering to ensure that you receive
the exact product you require.

Filament Design:
Filaments are designated by a letter combination in which C is a coiled wire filament,
CC is a coiled wire that is itself wound into a larger coil, and SR is a straight ribbon
filament. Numbers represent the type of filament-support arrangement.

Watts:
LIF Code:

Energy used. To find actual energy


used (kWh) multiply power (watts
shown) x time divided by 1000.

These are assigned by the Lighting


Federation of London, U.K. They
ensure electrical and mechanical
interchangeability of similarly
coded lamps. LIF codes are divided
into groups according to the
primary application of the lamps.

Shape:
Bulb shape followed by its size
(the maximum diameter of the bulb
expressed in eighths of an inch).

The lamps
identification code.

The type of base (ANSI).

Watts Shape

Order LIF
Volts Code Code

Base

Maximum Overall Length in inches.

LCL in.:
Distance between the
center of the filament
and the Light Center
Length reference
plane, in inches.

Lumens
Initial:
Initial light
output.

Description:

Base:

MOL in.:
Beam Spread:

Lamp burning hours to


median life expectancy.

For reflector type


lamps. The total angle
of the directed beam
(in degrees) to where
the intensity of the
beam falls to 50% or
10% of the maximum
value as indicated.

Color
Beam Spread
Case Lumens
Temp. Filament
10%
50%
Qty. Initial CBCP K Design MOL LCL Horiz. Vert. Horiz. Vert.

Description

Rated Life Hours:

Footnotes:
See pg 6-12.

Rated
Life
Hours

Footnotes

500

3, 12

QUARTZLINE TUNGSTEN HALOGEN


500 T6

Med Pf (P28s)

120 11966 T17

BTL-Q500T6/CL/P

12 11000

3000 C-13

5.25

2.18

BTL- Q500 T6/CL/P


Identifies the lamp
ANSI code.

6-6
06-StageAndStudio 2003.09

Identifies the
lamp's wattage.
Q=Quartz Halogen

Identifies the lamp


shape and the bulb
diameter in eighths
of inches.

WHEN YOU DONT KNOW THE LAMP DESCRIPTION


1. Identify bulb shape by using tables on pages 6-2 6-4.
2. Measure bulb diameter using ruler in Appendix section page A-1
to determine width in eighths of an inch.
3. Identify base type using table on page 6-4.
4. Find your lamp in the table containing the bulb shape, size and base.

For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose
the one with the lowest watts. All footnote references found at the end of this section.
Reduced Wattage High Color Rendering

01/23/04, 11:54 AM

Stage and Studio Lamps

Watts Shape

Base

Order LIF
Volts Code Code

Description

Color
Beam Spread
Case Lumens
Temp. Filament
10%
50%
Qty. Initial CBCP K Design MOL LCL Horiz. Vert. Horiz. Vert.

Rated
Life
Hours

Footnotes

50
50
400
300
1000
75
400
400
2000
2000
500
150
150
2000
500
150
500
400
300
1500
300
1500
300
300
1500
300
2000
2000
25
30
100
100
100
30
30
400
100
100
200
400
400
400
300
2000
300
1500
300
2000
300
1500

12
12
2, 12
12
12
12
2, 12
2, 7, 12
12
8, 12
3, 12
3, 12
12
12
12
3, 12
12
2, 12
12
12
12
12
12
12
12
12
12
3, 12
3, 12
13
13
13
13
13
13
2, 12
12
7, 12
3, 12
2, 12
2, 12
2, 12
12
12
12
12
12
12
12
12

QUARTZLINE TUNGSTEN HALOGEN


200
300
350
375

T4
T8
T2
T6

Cand DC Bay BA15d


2-Pin Pf (GY9.5)
R7S
Special

120
120
120
115

420 G7
500 T3

2-Pin Pf (GY9.5)
R7S

120
120

T4
T6

Med Pf (P28s)
Mini-Cand (E11)
Med Pf (P28s)

120
120
120

T7
T6

Med BiPost (G22)


Med 2-Pin (G9.5)

120
120

T8
T4
525 T3
550 T6
575 T6

2-Pin Pf (GY9.5)
Med Pf (P28s)
R7S
Special
Med 2-Pin (G9.5)

120
120
120
115
115

Special

115
120

600 T5
2-Pin Pf (GY9.5)
650 G6
2-Pin Pf (GX9.5)
PAR36 Ferrule

Screw Term

T3
T4
T8
675 T3
750 T3
T6

120
120
120

120

R7S
R7S

120
120

2-Pin Pf (GY9.5)
R7S
R7S

120
120
120

Med 2-Pin (G9.5)

120

Med Pf (P28s)

120

Special

115

14119
39781 CP81
20881
17608
18189
33934
23735
23734 P2/31
39135
47950
11966 T17
16465
30373
39768
39789
39623 CP82
39134
20883
17607
39730
11450
93428
93429
92431
92434
92433
92435
30475
34328
41668
41672
41673
41667
41669
41671
13895
30325 P2/6
30343 P2/6
39637 CP89
20884
23756
23755
39771
39770
92771
92773
39136
39137
92432
92770

FEV-Q200/4CL/DC
FKW-Q300T8
FDF/HIR-Q350T2/4
HPL375/C 115V
HPL375/LL/C 115V
EKB-Q420/4CL/2PP
FDF-Q500T3/4CL
FDN-Q500T3/4
EGE-Q500CL/P
EVR-Q500CL/MC
BTL-Q500T6/CL/P
BTM-Q500T64CL/2P
EGN-Q500T8
EHD-Q500CL/TP
EHC-Q500/5CL
FRG-Q500T8
EGC-Q500/5CL/P
EJG/HIR-Q525T2 -1
HPL550/C 77 V
FLK/LL-Q575T6
FLK-Q575T6/4CL
GLA-Q575T6/4CL
GLC-Q575T6/5CL
HPL575/C115V
HPL575/LL/C 115V
HPL575/C 120V
HPL575/LL/C 120V
FMR-Q600T5
EKD-Q650/3CL/2PP
FAY-Q650PAR36/3D
FCW-Q650PAR36/6
FCX-Q650PAR36/7
DWE-Q650PAR36/1
FBE-Q650PAR36/5D
FBO-Q650PAR36/5
FCM/HIR-Q650T3/4
FAD-Q650T4/4CL
FBX-Q650T4/4
FRK-Q650T8
FFT/HIR-Q675T3/4
EJG-Q750T3/4CL
EMD-Q750T3/4
EHF-Q750/4CL
EHG-Q750CL/TP
GLD-Q750T6/4CL
GLE-Q750T6/4CL
EGF-Q750/4CL/P
EGG-Q750CL/P
HPL750/C 115V
HPL750/LL/C

6
24
6
12
12
24
12
12
12
6
12
12
12
24
24
24
12
6
12
24
24
24
24
12
12
12
12
24
24
12
12
12
12
12
12
6
24
24
24
6
12
12
24
24
24
24
12
12
12
12

5500
6900
13250
10540
8000
11000
13250
12800
10450
10450
11000
13000
13000
10000
12700
13000
12700
20600
16170
12800
16500
13000
14500
16500
12360
16520
12360
12600
20000
36000
9000
24000
24000
36000
67000
25200
16500
16500
16900
26400
20600
19500
20000
15000
19000
17400
20400
15750
22000
16400

3200
3200
3200
3250
3050
3200
3200
3200
2950
2950
3000
3200
3200
2900
3150
3200
3150
3250
3250
2950
3200
3050
3200
3200
3050
3200
3050
3050
3300
5000
3200
3200
3200
5000
3400
3275
3200
3200
3200
3250
3200
3200
3200
3000
3200
3050
3200
3000
3200
3050

CC-2V
C-13
C-8
4-C8
4-C8
CC-6
C-8
C-8
CC-8
CC-8
C-13
C-13
C-13
CC-8
CC-8
C-13
CC-8
C-8
4-C8
CC-8
CC-8
C-13D
C-13D
4C-8
4C-8
4C-8
4C-8
CC-8
CC-6
C-7A
C-7A
C-7A
C-7A
C-7A
C-8
CC-8
CC-8
C-13
C-8
C-8
C-8
CC-8
CC-8
C-13D
C-13D
CC-8
CC-8
4-C-8
4-C-8

2.43
3.54
4.68
4.17
4.17
2.5
4.68
4.68
6
3.62
5.25
5.25
5.51
4.1
4.1
3.54
6
4.68
4.17
4.1
4.1
4.1
4.1
4.2
4.2
4.2
4.2
3.4
2.5
2.75
2.75
2.75
2.75
2.75
2.75
4.68
3.13
3.13
3.54
6.56
4.68
4.68
4.1
4.1
4.1
4.1
6
6
4.17
4.17

1.37
1.81
2.37
2.37
1.43

3.5
2
2.18
2.18
2.5
2.37
2.37
1.81
3.5
2.37
2.37
2.37
2.37
2.37
2.37
2.37
2.37
2.37
2
1.43
25
60
40
40
25
25

1.81

2.37
2.37
2.37
2.37
3.5
3.5
2.37
2.37

15
55
30
30
15
15

For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose
the one with the lowest watts. All footnote references found at the end of this section.
Reduced Wattage High Color Rendering

06-StageAndStudio 2003.09

01/23/04, 11:54 AM

B
B

6-7

Stage and Studio Lamps

Watts Shape

Base

Order LIF
Volts Code Code

Description

Color
Beam Spread
Case Lumens
Temp. Filament
10%
50%
Qty. Initial CBCP K Design MOL LCL Horiz. Vert. Horiz. Vert.

Rated
Life
Hours

Footnotes

1, 3, 12
1, 11, 12
1, 11, 12
1, 3, 12
13
13
13
13
13
13
1, 13
1, 13
2, 12
2, 12
2, 7, 12
2, 12
12
7, 12
10, 12
12
12
12
12
10, 12
1, 3, 12
1, 12
1, 3, 12
1, 3, 12
1, 3, 12
1, 3, 12
13
13
13
1, 13
1, 13
2, 12
2, 7, 12
3, 12
1, 3, 12
2, 12
12
3, 12
1, 3, 12
3, 12
1, 4, 12
1, 4, 12
4, 12
12
12

QUARTZLINE TUNGSTEN HALOGEN (CONTINUED)


750 T7

Med BiPost (G22)


Med Pf (P28s)

Med 2-Pin (G9.5)


1000 PAR64 ExMogEndPr

PS52 Mog (E39)


ED37 Mog (E39)
T3
R7S

T5

R7S

T6

Med 2-Pin (G9.5)


Med Pf (P28s)

T7

R7S
Med 2-Pin (G9.5)
Med 2-Pin (G9.5)
Med Pf (P28s)
Med BiPost (G22)
Mog BiPost (G38)
Mog Pf (P40s)

1200 PAR64 ExMogEndPr

1500 PS52 Mog (E39)


ED37 Mog (E39)
T4
R7S
T8
T10
2000 T10
T8
T10
5000 T20
10000 T24
12000 T26

Mog Pf (P40s)
Mog BiPost (G38)
R7S
Mog (E39)
Mog BiPost (G38)
Mog BiPost (G38)
Mog Pf (P40s)
Mog BiPost (G38)
Mog BiPost (G38)
GX38

120 39190
120 11953
11954
120 39680
120 13233
13229
13228
13227
13226
13225
120 39582
120 34377
120 23797 P2/28
33280
23792 P2/29
185 23788
120 30157
30374
120 39769 CP77
120 38853
38852
39138
120 33760
120 35853
120 39792
120 11955
120 39191
120 42697
120 12554
12553
120 34812
34810
34808
120 40357
120 34378
120 23841
41229
120 30522
120 37564
120 39790 P2/27
120 37086
120 39587
120 36636
120 12555 CP53
120 41736 CP29
120 18305
120 48770

EGR-Q750T7/4CL
BTN-Q750T7/CL/2P
BTP-Q750T7/4CL2P
BWM-Q750T7/4CLTP
FFN-Q1000PAR64/1
FFP-Q1000PAR64/2
FFR-Q1000PAR64/5
FFS-Q1000PAR64/6
FGM-Q1000PAR64/3
FGN-Q1000PAR647D
DKZ/DSE-Q1000PS5
DSE/Q1000
FCM-Q1000T3/4CL
FFT-Q1000T3/1CL
FHM-Q1000T3/4
EJD-Q1000T3/3CL
DXW-Q1000T5/4CL
FBY-Q1000T5/4
FEL-Q1000/4CL
EGJ-Q1000/4CL/P
EGK-Q1000/4/P
EGM-Q1000CL/P
FER-Q1000T6/4CL
FCV-Q1000/4
BWN-Q1000T7/4CL
BTR-Q1000T74CL2P
EGT-Q1000T7/4CL
CYVQ1000T7/4CLBP
BVT-Q1MT7/CL/MP
BVV-Q1MT7/4CL/MP
GFA-Q1200PAR64/5
GFB-Q1200PAR64/2
GFC-Q1200PAR64/1
DKX/DSFQ1500PS52
DSF/Q1500
FDB-Q1500T4/4CL
FGT-Q1500T4/4
DTA-Q1500T8/4CL
CXZ-Q1500T10/4CL
FEY-Q2000T8/4CL
BWF-Q2000/4CL
BWA-Q2000/4CL/BP
CYX-Q2000T10/4CL
BVWQ2MT10/4CL/MP
DPY-Q5000T20/4CL
DTY-Q10M/T24/4CL
Q12MT26/4CL 120V

12
12
12
6
6
6
6
6
6
6
12
10
12
12
12
12
24
24
24
12
12
12
6
6
24
12
12
6
6
6
6
6
6
12
10
12
12
6
6
12
6
6
6
6
6
4
1

21000
17600
21000
21000
400000
330000
125000
40000
200000
70000
28000
28000
28000
26400
27300
33600
28000
26000
27500
27500
26500
21500
27500
26500
28500
28500
28500
28500
24500
28500
160000
450000
540000
41000
41000
41250
40200
41000
44500
57000
54000
54000
59000
59000
143000
290000
420000

3200
3050
3200
3200
3200
3200
3200
3200
5200
5200
3200
3200
3200
3200
3200
3350
3200
3200
3200
3200
3200
3000
3200
3200
3200
3200
3200
3200
3050
3200
3200
3200
3200
3200
3200
3200
3200
3200
3200
3200
3200
3200
3200
3200
3200
3200
3400

C-13D
C-13D
C-13D
C-13D
C-7A
C-7A
C-7A
C-7A
C-7A
C-7A
CC-8
CC-8
C-8
C-8
C-8
C-8
CC-8
CC-8
CC-8
CC-8
CC-8
CC-8
CC-8
CC-8
C-13D
C-13D
C-13D
C-13D
C-13D
C-13D
C-7A
C-7A
C-7A
C-8
C-8
C-8
C-8
C-13D
C-13
CC-8
CC-8
CC-8
C-13
C-13
C-13
C-13
C-13

5
4.75
4.75
4.5
6
6
6
6
6
6
13
13
4.68
6.56
4.68
4.68
3.75
3.75
4.1
6
6
6
5.62
4.1
4.5
4.75
5
8
7.25
7.25
6
6
6
13
13
6.56
6.56
7.87
8.5
5.62
7.5
8.25
8.5
8.46
11
15.75
16.14

2.5
2.18
2.18
2.37

5.25
5
5
3.93
6.5
10
10

200
500
200
200
800
800
800
800
200
200
750
750
400
400
400
100
150
150
300
300
300
2000
500
375
250
250
250
200
500
200
400
400
400
1000
1000
400
400
300
400
400
500
500
350
350
500
300
150

4.2
4.2

2.37
2.37

300
1500

24
26
44
71
24
43

10
14
21
45
12
20

12
14
28
48
13
27

6
7
12
24
6
11

22
16
14

36
18
16

13
8
8

24
10
10

9.5
9.5

2.37
3.5
3.5
3.5
2.37
2.37
2.18
2.5
5
3.93
3.93

3.43
5

QUARTZLINE TUNGSTEN HALOGEN HIGH VOLTAGE


575 T6

Special

230 37128
37817

6-8
06-StageAndStudio 2003.09

HPL575
HPL575/LL 230V

12 14900
12 11780

3200 6C-8
3050 6C-8

For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose
the one with the lowest watts. All footnote references found at the end of this section.
Reduced Wattage High Color Rendering

01/23/04, 11:54 AM

Stage and Studio Lamps

Watts Shape

Base

Order LIF
Volts Code Code

Description

Color
Beam Spread
Case Lumens
Temp. Filament
10%
50%
Qty. Initial CBCP K Design MOL LCL Horiz. Vert. Horiz. Vert.

Rated
Life
Hours

Footnotes

250
300
300
300
300
300
300
130
130
400
400
400
150
150

12
12
12
13
13
13
2, 12
4, 12
4, 12
4, 12
4, 12
4, 12
4, 12
4, 12

QUARTZLINE TUNGSTEN HALOGEN HIGH VOLTAGE (CONTINUED)


600 T6
750 T6
1000 T6
PAR64

Med 2-Pin (G9.5)


Special
Med 2-Pin (G9.5)
ExMogEndPr

230
230
230
240

2000 T10
12000 T26

R7S
GX38

20000 T32

GX38

24000 T32

GX38

230
230
240
208
220
240
220
240

39739
37824
39738 CP77
10925
10929
10931
35338 P2/27
48771
48779
48772
48773
48774
48776
48777

GKV-Q575T6/4CL
HPL750
FEP-Q1000T6/4CL
EXC-Q1MPAR64CP60
EXD-Q1MPAR64CP61
EXE-Q1MPAR64CP62
FEX-Q2MT8/4CL
Q12MT26/4CL 230V
Q12MT264/CL 240V
BCM Q20MT32/4CL
BCM Q20MT32/4CL
BCM Q20MT32/4CL
Q24MT32/4CL 220V
Q24MT32/4CL 240V

24
12
24
6
6
6
12
1
1
1
1
1
1
1

14000
19750
25000

3200
3200
3200
352000 3200
297000 3200
138000 3200
50000
3200
420000
3400
420000
3400
580000
3200
580000
3200
580000
3200
800000
3400
800000
3400

C-13
6C-8
CC-8
C-7A
C-7A
C-7A
CC-8
C-13
C-13
C-13
C-13
C-13
C-13
C-13

4.1
4.2
4.1
6
6
6
5.62
16.14
16.14
22.05
22.05
22.05
22.05
22.05

2.37
2.37
2.37

15722
15723
15724
15725
15558
15710
15714
15715
47868
47869
15712
15713
47857
47864
15716
15717
15718
15719
15720
15721

F15T8/CINEMA32
F15T8/CINEMA55
F17T8/CINEMA32
F17T8/CINEMA55
F20T12/CINEMA32
F20T12/CINEMA55
F30T12/CINEMA32
F30T12/CINEMA55
F32T8/CINEMA32
F32T8/CINEMA55
F20T12/CINEMA32/HO
F20T12/CINEMA55/HO
F40T12/CINEMA32
F40T12/CINEMA55
F40T12/CINEMA32/HO
F40T12/CINEMA55/HO
F72T12/CINEMA32/HO
F72T12/CINEMA55/HO
F96T12/CINEMA32/HO
F96T12/CINEMA55/HO

24
24
24
24
24
24
24
24
36
36
24
24
30
30
30
30
15
15
15
15

720
700
800
770
780
760
1450
1400
1800
1750
1130
1100
2000
1950
2900
2820
4150
4050
5800
5650

3200
5500
3200
5500
3200
5500
3200
5500
3200
5500
3200
5500
3200
5500
3200
5500
3200
5500
3200
5500

18
18
24
24
24
24
36
36
48
48
24
24
48
48
48
48
72
72
96
96

8000
8000
20000
20000
10000
10000
18000
18000
20000
20000
7500
7500
20000
20000
15000
15000
15000
15000
15000
15000

F15T8/CINEMA32/CVG
24
F15T8/CINEMA55/CVG
24
F17T8/CINEMA32/CVG
24
F17T8/CINEMA55/CVG
24
F20T12/CINEMA32/CVG 24
F20T12/CINEMA/55CVG 24
F30T12/CINEMA32/CVG 24
F30T12/CINEMA/55/CVG 24
F32T8/CINEMA32/CVG
36
F32T8/CINEMA55/CVG
36
F20T12/CINEMA32/HO/CVG 24
F20T12/CINEMA55/HO/CVG 24

720
700
800
770
780
760
1450
1400
1800
1750
1130
1100

3200
5500
3200
5500
3200
5500
3200
5500
3200
5500
3200
5500

18
18
24
24
24
24
36
36
48
48
24
24

8000
8000
20000
20000
10000
10000
18000
18000
20000
20000
7500
7500

20
22
38
10
10
13.94
13.94
13.94
13.94
13.94

17
20
20

12
14
24

9
10
11

CINEMA LAMPS
FLUORESCENT LAMPS
15 T8

Medium BiPin (G13)

17 T8

Medium BiPin (G13)

20 T12

Medium BiPin (G13)

30 T12

Medium BiPin (G13)

32 T8

Medium BiPin (G13)

35 T12

Medium BiPin (G13)

40 T12

Medium BiPin (G13)

60 T12

Medium BiPin (G13)

85 T12

Medium BiPin (G13)

110 T12

Medium BiPin (G13)

FLUORESCENT COVRGUARD LAMPS


15 T8

Medium BiPin (G13)

17 T8

Medium BiPin (G13)

20 T12

Medium BiPin (G13)

30 T12

Medium BiPin (G13)

32 T8

Medium BiPin (G13)

35 T12

Medium BiPin (G13)

15800
15801
15806
15810
15766
15774
15779
15780
47881
47882
15775
15776

For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose
the one with the lowest watts. All footnote references found at the end of this section.
Reduced Wattage High Color Rendering

06-StageAndStudio 2003.09

01/23/04, 11:54 AM

6-9

Stage and Studio Lamps

Watts Shape

Base

Order LIF
Volts Code Code

Description

Color
Beam Spread
Case Lumens
Temp. Filament
10%
50%
Qty. Initial CBCP K Design MOL LCL Horiz. Vert. Horiz. Vert.

Rated
Life
Hours

Footnotes

CINEMA LAMPS (CONTINUED)


FLUORESCENT COVRGUARD LAMPS (CONTINUED)
40 T12

Medium BiPin (G13)

60 T12

Medium BiPin (G13)

85 T12

Medium BiPin (G13)

110 T12

Medium BiPin (G13)

47876
47877
15782
15783
15785
15786
15794
15798

F40T12/CINEMA32/CVG 30
F40T12/CINEMA55/CVG 30
F40T12/CINEMA32/HO/CVG 30
F40T12/CINEMA55/HO/CVG 30
F72T12/CINEMA32/HO/CVG 15
F72T12/CINEMA55/HO/CVG 15
F96T12/CINEMA32/HO/CVG 15
F96T12/CINEMA55/HO/CVG 15

2000
1950
2900
2820
4150
4050
5800
5650

3200
5500
3200
5500
3200
5500
3200
5500

48
48
48
48
72
72
96
96

20000
20000
15000
15000
15000
15000
15000
15000

15816
15819
15811
15814
22084
22085

F36BX/CINEMA32
F36BX/CINEMA56
F55BX/CINEMA32
F55BX/CINEMA56
F55BX/CINPLUS/32
F55BX/CINPLUS/56

10
10
10
10
10
10

2900
2900
4100
4100
2400
2400

3200
5600
3200
5600
3200
5600

21.1
21.1
21.1
21.1
21.1
21.1

8000
8000
8000
8000
8000
8000

CSD250/2/SE
CSR575/2/T/SE
CSR575/2/SE
CSR700/2/SE
CSR1200/2/SE

10
10
10
10
6

18000
49000
49000
55000
110000

8500
7200
7200
7200
7200

4.92
4.92
6.1
6.9

2.56
2.56
2.95
3.35

2000
1000
1000
1000
800

6, 13
6, 13
6, 13
6, 13
6, 13

6 55000
6 96000
6 155000

5600
5600
6000

3.3
5.3
5.3

1.5
2.3
2.3

750
1000
750

6, 13
6, 9, 13
6, 9, 13

CSR125/SE/HR
CSR200/SE/HR
CSR400/SE/HR
CSR575/SE/HR
CSR1200/SE/HR
CSR2500/SE/HR
CSR4000SE/HR
CSR6000/SE/HR
CSR12000/SE/HR

10 9400
10 15000
10 32000
10 48000
6 110000
6 220000
6 380000
6 540000
41100000

5600
5600
6000
6000
6000
6000
6000
6000
6000

2.95
3.15
4.32
5.71
7.87
9.45
9.84
14.17
17.72

1.53
1.53
2.38
2.76
4.21
5
5.59
8.27
10.04

200
200
650
750
750
500
500
300
250

6, 13
6, 13
6, 9, 13
6, 13
6, 13
6, 13
6, 13
6, 13
6, 13

CSR200/DE
CSR575/DE
CSR1200/S/DE
CSR1200/DE
CSR2500/DE
CSR4000/DE
CSR6000/DE
CSR12000/DE
CSR18000/DE
CSR18000/S/DE

10 16000
10 49000
10 110000
6 110000
6 240000
6 410000
6 570000
41100000
41650000
41650000

6000
6000
6000
6000
6000
6000
6000
6000
6000
6000

2.95
5.71
5.71
8.66
14
15.94
17.71
18.5
19.69
18.5

300
750
500
750
500
500
300
300
300
300

5, 6, 13
5, 6, 13
5, 6, 13
5, 6, 13
5, 6, 13
5, 6, 13
5, 6, 13
5, 6, 13
5, 6, 13
5, 6, 13

FLUORESCENT BIAX
36 T5

2G11-4 Pin

55 T5

2G11-4 Pin

CSR METAL HALIDE LAMPS


SINGLE-ENDED COLD START
250 T7
575 T9
700 T9
1200 T12

GY9.5
GX9.5
G22
G22/30X53

90 10744
97 49492
15378
70 49491
100 49490

SINGLE-ENDED SHORT ARC


700 G7
1200 G8
1800 G8

GY9.5
GY22
GY22

70 15380
100 21849
207 21801

CSR700SA
CSR1200SA
CSR2000/SA

SINGLE-ENDED HOT RESTRIKE


125
200
400
575
1200
2500
4000
6000
12000

T5
T5
T6
T10
T13
T20
T24
T27
T32

GZX9.5
GZY9.5
GZZ9.5
G22
G38
G38
G38
G38
G38

80
70
70
95
100
100
200
130
160

48461
48462
21853
48463
48464
48465
48466
48467
48468

DOUBLE-ENDED HOT RESTRIKE


200 T5
575 T7
1200 T7
T9
2500 T10
4000 T12
6000 T16
12000 T23
18000 T28

x515
SFc 10-4
SFc 10-4
SFC10.5-6
SFa 21-12
SFa 21-12
25x51 Cyl 165mm
30x70 Cyl 165mm
30x70 Cyl 165mm

80
95
100
100
115
200
125
160
225

6-10
06-StageAndStudio 2003.09

48450
48451
48452
48453
48454
48455
48456
48457
48459
48460

For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose
the one with the lowest watts. All footnote references found at the end of this section.
Reduced Wattage High Color Rendering

10

01/23/04, 11:54 AM

Stage and Studio Lamps

STAGE AND STUDIO ANSI CODES REFERENCE


ANSI Order
Code Code

Lamp
Description

Volts

ANSI Order
Code Code

Lamp
Description

Volts

ANSI Order
Code Code

Lamp
Description

Volts

ANSI Order
Code Code

Lamp
Description

Volts

STAGE & STUDIO ANSI CODES

STAGE & STUDIO ANSI CODES

STAGE & STUDIO ANSI CODES

STAGE & STUDIO ANSI CODES

BCM
BCM
BCM
BTL
BTM
BTN
BTP
BTR
BVT
BVV
BVW
BWA
BWF
BWM
BWN
CXZ
CYV
CYX
DKX
DKZ
DPY
DSE
DTA
DTY
DWE

DXW
EGC
EGE
EGF
EGG
EGJ
EGK
EGM
EGN
EGR
EGT
EHC
EHD
EHF
EHG
EJD
EJG
EJG
EKB
EKD
EMD
EVR
EXC
EXC
EXD

EXD
EXE
EXE
FAD
FAY
FBE
FBO
FBX
FBY
FCM
FCM
FCV
FCW
FCX
FDB
FDF
FDF
FDN
FEL
FEP
FER
FEV
FEX
FEY
FFN

FFP
FFR
FFS
FFT
FFT
FGM
FGN
FGT
FHM
FKW
FLK
FLK
FMR
FRG
FRK
GFA
GFB
GFC
GKV
GLA
GLC
GLD
GLE

48772 BCM Q20MT32/4CL 208


48773 BCM Q20MT32/4CL 220
48774 BCM Q20MT32/4CL 240
11966 BTL-Q500T6/CL/P
120
16465 BTM-Q500T64CL/2P 120
11953 BTN-Q750T7/CL/2P 120
11954 BTP-Q750T7/4CL2P 120
11955 BTR-Q1000T74CL2P 120
12554 BVT-Q1MT7/CL/MP 120
12553 BVV-Q1MT7/4CL/MP 120
12555 BVWQ2MT10/4CL/MP 120
39587 BWA-Q2000/4CL/BP 120
37086 BWF-Q2000/4CL
120
39680 BWM-Q750T7/4CLTP 120
39792 BWN-Q1000T7/4CL 120
37564 CXZ-Q1500T10/4CL 120
42697 CYVQ1000T7/4CLBP 120
36636 CYX-Q2000T10/4CL 120
40357 DKX/DSFQ1500PS52 120
39582 DKZ/DSE-Q1000PS5 120
41736 DPY-Q5000T20/4CL 120
34377 DSE/Q1000
120
30522 DTA-Q1500T8/4CL
120
18305 DTY-Q10M/T24/4CL 120
41667 DWE-Q650PAR36/1 120

ANSI Order
Code Code

Lamp
Description

30157 DXW-Q1000T5/4CL
39134 EGC-Q500/5CL/P
39135 EGE-Q500CL/P
39136 EGF-Q750/4CL/P
39137 EGG-Q750CL/P
38853 EGJ-Q1000/4CL/P
38852 EGK-Q1000/4/P
39138 EGM-Q1000CL/P
30373 EGN-Q500T8
39190 EGR-Q750T7/4CL
39191 EGT-Q1000T7/4CL
39789 EHC-Q500/5CL
39768 EHD-Q500CL/TP
39771 EHF-Q750/4CL
39770 EHG-Q750CL/TP
23788 EJD-Q1000T3/3CL
20883 EJG/HIR-Q525T2 -1
23756 EJG-Q750T3/4CL
33934 EKB-Q420/4CL/2PP
34328 EKD-Q650/3CL/2PP
23755 EMD-Q750T3/4
47950 EVR-Q500CL/MC
93409 EXC-Q1MPAR64CP60
10925 EXC-Q1MPAR64CP60
10928 EXD-Q1MPAR64CP61

120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
185
120
120
120
120
120
120
230
240
230

10929 EXD-Q1MPAR64CP61
10930 EXE-Q1MPAR64CP62
10931 EXE-Q1MPAR64CP62
30325 FAD-Q650T4/4CL
41668 FAY-Q650PAR36/3D
41669 FBE-Q650PAR36/5D
41671 FBO-Q650PAR36/5
30343 FBX-Q650T4/4
30374 FBY-Q1000T5/4
13895 FCM/HIR-Q650T3/4
23797 FCM-Q1000T3/4CL
35853 FCV-Q1000/4
41672 FCW-Q650PAR36/6
41673 FCX-Q650PAR36/7
23841 FDB-Q1500T4/4CL
20881 FDF/HIR-Q350T2/4
23735 FDF-Q500T3/4CL
23734 FDN-Q500T3/4
39769 FEL-Q1000/4CL
39738 FEP-Q1000T6/4CL
33760 FER-Q1000T6/4CL
14119 FEV-Q200/4CL/DC
35338 FEX-Q2MT8/4CL
39790 FEY-Q2000T8/4CL
13233 FFN-Q1000PAR64/1

240
230
240
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
230
120
120
230
120
120

13229 FFP-Q1000PAR64/2
13228 FFR-Q1000PAR64/5
13227 FFS-Q1000PAR64/6
20884 FFT/HIR-Q675T3/4
33280 FFT-Q1000T3/1CL
13226 FGM-Q1000PAR64/3
13225 FGN-Q1000PAR647D
41229 FGT-Q1500T4/4
23792 FHM-Q1000T3/4
39781 FKW-Q300T8
39730 FLK/LL-Q575T6
11450 FLK-Q575T6/4CL
30475 FMR-Q600T5
39623 FRG-Q500T8
39637 FRK-Q650T8
34812 GFA-Q1200PAR64/5
34810 GFB-Q1200PAR64/2
34808 GFC-Q1200PAR64/1
39739 GKV-Q575T6/4CL
93428 GLA-Q575T6/4CL
93429 GLC-Q575T6/5CL
92771 GLD-Q750T6/4CL
92773 GLE-Q750T6/4CL

120
120
120
120
120
120
120
120
120
120
115
115
120
120
120
120
120
120
230
115
115
120
120

Volts

GENERAL LIGHTING ANSI


CODES (SEE SECTION HALOGEN)
DVS
EHM
EHP
EHR
EHT
EHZ
ESL
ESM
ESN
ESP
ESR
ESS
ETB
ETC
ETD
ETE
ETF
ETG
ETH
FCL

23733 Q500T3/CL-DVS
43703 Q300T3/CL-EHM
43705 Q300T4/CL-EHP
43708 Q400T4/CL-EHR
43699 Q250CL/MC-EHT
43704 Q300T3-EHZ
44383 Q150CL/MC/2V-ESL
43695 Q250MC-ESM
44385 Q100CL/MC/2V-ESN
44384 Q150CL/DC/2V-ESP
44386 Q100CL/DC/2V-ESR
43697 Q250CL/DC-ESS
43701 Q250DC-ETB
43693 Q150CL/DC-ETC
44657 Q100DC/2V-ETD
44656 Q100MC/2V-ETE
44653 Q150DC-ETF
43694 Q150CL/MC-ETG
44654 Q150MC-ETH
23731 Q500T3/CL-FCL

130
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120

For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose
the one with the lowest watts. All footnote references found at the end of this section.
Reduced Wattage High Color Rendering

06-StageAndStudio 2003.09

11

01/23/04, 11:54 AM

6-11

Stage and Studio Lamps

FOOTNOTES
# Footnote
1
2
3
4
5
6

7
8
9
10
11

13

Filament with low noise construction.


Burn position horizontal 4 degrees.
Burn position base down to horizontal.
Burning position vertical base down 45 degrees.
Burning position horizontal 15 degrees.
Enclosed fixture only per UL standard 1572. In accordance to Federal Regulations (21CFR 1040.30) the following
notice applies.
WARNING: This lamp can cause serious skin burn and eye inflammation from shortwave ultraviolet radiation
if the outer envelope of the lamp is broken or puntured, and the arc tube continues to operate. Do not use
where people will remain more than a few minutes unless adequate shielding or other safety precautions are
used. Certain types of lamp that will automatically extinguish when the outer envelope is broken or puntured
are commercially available.
Frosted. Apparent lighted length slightly longer than similar clear lamp.
Life dependent on service conditions; for use only in equipment specially designed to maintain bulb and base
temperatures within safe limits.
Available late 2003.
To avoid possible overheating, this lamp is not recommended for use without force-cooling in deep-bowled fixtures.
Burn vertical base down 30 degrees.

12
Safety Notice for exposed unshielded lamps (if shielded fixture
use footnote 13)
WARNING
Risk of electrical shock
Turn power off before inspection,installation or removal
Risk of fire
Keep combustible materials away from lamp
Use in enclosed fixture rated for this product
Pressurized lamp-unexpected rupture may cause injury, fire, or
property damage
Use eye protection when handling lamp
Do not touch glass with bare hands
Use in enclosed fixtures rated for this product
Do not use lamp if outer glass is scratched or broken
Operate lamp only in specified position
Do not exceed 110% of rated voltage
CAUTION
Risk of burn
Allow lamp/fixture to cool before handling
Turn power off before installing lamp
Lamp may shatter and cause injury if broken
Do not use lamp if outer glass is scratched or broken
Dispose of lamp in a closed container
Wear safety glasses and gloves when handling lamp
Lamp emits UV ratiation which may cause eye/skin irritation. RG-2.
Limit unshielded exposure to less than 15 minutes per day

6-12
06-StageAndStudio 2003.09

Safety Notice for PAR lamps and enclosed, shielded lamps


WARNING
Risk of electrical shock
Turn power off before inspection, installation or removal
Risk of fire
Keep combustible materials away from lamp
Use in fixture rated for this product
A damaged lamp emits UV radiation which may cause eye/skin injury
Turn power off if glass is broken. Remove and dispose of lamp
Pressurized lamp-unexpected rupture may cause injury, fire, or
property damage
Use in enclosed fixtures rated for this product
Do not use lamp if outer glass is scratched or broken
Do not exceed 110% of rated voltage
Avoid direct water/liquid contact
CAUTION
Risk of burn
Allow lamp/fixture to cool before handling
Turn power off before installing lamp
Lamp may shatter and cause injury if broken
Do not use lamp if outer glass is scratched or broken
Dispose of lamp in a closed container

For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose
the one with the lowest watts. All footnote references found at the end of this section.
Reduced Wattage High Color Rendering

12

01/23/04, 11:54 AM

Stage and Studio Lamps

NOTES

For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose
the one with the lowest watts. All footnote references found at the end of this section.
Reduced Wattage High Color Rendering

06-StageAndStudio 2003.09

13

01/23/04, 11:54 AM

6-13

Stage and Studio Lamps

NOTES

6-14
06-StageAndStudio 2003.09

For the most up-to-date product information, see www.gelighting.com. To save energy costs, find the bulbs with the light output you need, then choose
the one with the lowest watts. All footnote references found at the end of this section.
Reduced Wattage High Color Rendering

14

01/23/04, 11:54 AM

Você também pode gostar