ALTIVAR 28 Quick Reference Guide

Access to Menus

Keypad Operation & Reference

1st power-up after factory configuration

Enters a menu or a
parameter, or saves
the displayed
parameter or value

ESC ENT

rdY
ENT

Exits a menu or parameter,


or aborts the displayed value
to return to the previous
value in the memory

Goes to the next menu or


parameter, or decreases
the displayed value

SEt

Settings

LFr
rPI
rOt
ACC
dEC
AC2
dE2
LSP
HSP
ItH
UFr
SLP
FLG
IdC
tdC
JPF
JOG
rPG
rIG
rbS
PIC
SP2
SP3
SP4
SP5
SP6
SP7
Ftd
Ctd
ttd
tLS

Menu 2 Drive Menu (DrC)


Parameter
Nominal Motor Voltage
Nominal Motor Frequency
Auto-tuning
Maximum Output Frequency
Type of Volts/Hz Ratio
Automatic Ramp Modification for Decel
Alternate Accel/Decel Ramp Frequency
Carrier Switching Frequency
Random Carrier Frequency Modulation
Automatic Restart
Enable Output Phase Failure Fault
Enable Line Supply Phase Failure Fault
Controlled Stop on Loss of Line Supply
Enable Smooth Restart after Fault
Lower Tripping Threshold of Undervoltage
Scale Factor of Output Frequency for Speed
Return to Factory Settings

Code
UnS
FrS
tUn
tFr
Ft
brA
Frt
SFr
nrd
Atr
OPL
IPL
StP
FLr
drn
SdS
FCS

Menu 3 I/O Menu (I-O)


Parameter
Control Strategy Configuration (2-wire/3-wire)
2-Wire Control
3-Wire Control
Presence of Local Control Option
Enable for Start/Stop using Remote Display
Logic Input 2 Assignment
Logic Input 3 Assignment
Logic Input 4 Assignment
Not Assigned
Reverse Rotation
Ramp Switching

Code
tCC
2C
3C
OPt
LCC
LI2
LI3
LI4
no
rrS
rP2

Factory
Setting
0.0
For
3 sec
3 sec
5 sec
5 sec
0 Hz
(bFr)
(In)
20
0.05.0 Hz
33
0.7In
0.5 sec
0 Hz
10 Hz
1
1 /s
1
no
10 Hz
15 Hz
20 Hz
25 Hz
30 Hz
35 Hz
(bFr)
1.5In
100%
0
Factory
Setting
230/460V
50/60 Hz
no
60/72 Hz
n
YES
0 Hz
4.0
YES
no
YES
YES
no
no
no
30
no
Factory
Setting
2C

no
rrS
PS2
PS4

drC

I-O-

I/O

SUP-

ESC

Display

Access to Parameters
Parameter

Menu

SEt-

ENT
ESC

Value or assignment

-YYY

ENT

ESC

-UUU

100

1 flash
(save)

ESC
ENT

101

101

Next parameter

Menu 3 I/O Menu (I-O) continued


Parameter
Jog Operation
2 Preset Speeds
4 Preset Speeds
8 Preset Speeds
Freewheel Stop
DC Injection Braking
Fast Stop
Forced Local Mode
Fault Reset
Analog Speed Reference Switching
Analog Input Assignment of 2nd Input
Not Assigned
Summing with All
PI Regulator Feedback, setpoint = parameter rP1
PI Regulator Feedback, setpoint = All
Minimum Value on Analog Current Input
Maximum Value on Analog Current Input
Assignment of Analog Output
Not Assigned
Motor Current
Motor Frequency
Motor Torque
Drive Power Supplied
Assignment of Offset for Analog Output
Assignment of R2 Relay
Not Assigned
Frequency Threshold Reached
Current Threshold Reached
Speed Reference Reached
Motor Thermal Threshold Reached
Drive Address via Serial Link
Serial Link Transmission Speed

Code
JOG
PS2
PS4
PS8
nSt
dCI
FSt
FLO
rSt
rFC
AIC
no
SAI
PII
PIA
CrL
CrH
AO
no
Ocr
rFr
OLO
OPr
AOt
r2
no
FtA
CtA
SrA
tSA
Add
bdr

Menu 4 Display Menu (SUP)


Parameter
Control Strategy Configuration (2-wire/3-wire)
Enable for Start/Stop using Remote Display
Display Calculated Value of Speed or
Production Rate (rFr X SdS)
Display Motor Current
Display Motor Power
Display Line Voltage
Display Motor Thermal State
Display Drive Controller Thermal State
Display Last Fault
Display Drive Controller Software Version
Access Code Protection
Display of Controller Status

The parameters in colored boxes appear if the corresponding


functions have been configured in the dcr or I/O menus.
Electrical equipment should be serviced only by qualified personnel. No responsibility is
assumed by Schneider Electric for any consequences arising out of the use of this
material. This document is not intended as an instruction manual for untrained persons.

If it is not possible to access the SEt-,


drC- or I-O- menus, the drive controller
is protected by an access code. A remote
display module option or PC software is
necessary to access these menus, together
with knowledge of the code.

Drive

Speed Reference via the Display Module


PI Reference
Direction of Operation
Acceleration Time
Deceleration Time
Acceleration Ramp #2
Deceleration Ramp #2
Low Speed
High Speed
Motor Full Load Current (protection)
Optimize Low Speed Torque (voltage boost)
Slip Compensation
Frequency Loop Gain
DC Injection Braking Current
DC Injection Braking Time at Standstill
Skip Frequency
Jog Frequency
PI Regulator Proportional Gain
PI Regulator Integral Gain
PI Feedback Multiplication Coefficient
PI Regulator Reverse Coefficient
Preset Speed 2nd
Preset Speed 3rd
Preset Speed 4th
Preset Speed 5th
Preset Speed 6th
Preset Speed 7th
Frequency Threshold where R2 Closes
Current Threshold where R2 Closes
Motor Thermal where R2 Closes
Low Speed Operation Time

Code

Wait 3 seconds

Parameter

Display of drive controller status

----

Menu 1 Adjustment Menu (SEt)

Subsequent power-ups

ENT
bFR configuration (1)
ENT

4 seven-segment displays

rdY

Returns to the
previous menu or
parameter, or
increases the
displayed value

Base frequency:
50 Hz (factory setting) or 60 Hz

-bFr

Altivar28

Red LED: powered up


(DC bus voltage)

Using the Keypad Display

Document Number 8806HO0102

Code
FrH
rFr
SPd
LCr
OPr
ULn
tHr
tHd
LFt
CPU
COd

Factory
Setting

SAI

4 mA
20 mA
rFr

0
SrA

1
19.2
Factory
Setting
Hz
Hz

A
%
V
%
%

ESC