M

Mobile ductless filtration fume hood for personal protection


during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter
and particulate filtration on H14 HEPA filter.

481

Your protection is only guaranteed after you receive approval from the erlab laboratory. Please contact your supplier and benefit from the ESP (Erlab Safety Program) for a validation of
the safety parameters (type of column, filter lifetime, saturation detection method and replacement filter procedure...), linked to the use of this cabinet.

Technical specifications

Ref.
M 481

Internal dimensions - without work surface

Width

Depth

Height*

Width

Depth

Height

50 1/4

24 3/4

45 3/4 min
53 maxi

48 7/8

21 1/2

34

*According to filtration column type

Number of columns

Number of fans (IP44)

1
135 cfm

Processed air flow

Air velocity at the openings in


79 fpm to 118 fpm
working position

Structure

Voltage / Frequency

Anti-corrosion metallic alloy protected by a thermo-hardened


anti-acid polymer coating

Metallic parts

Modular filtration column

Total power consumption


(Including electricity for the lights)

Amperage absorbed

1/4 thick acrylic

Side and front panels

90 - 264 V / 50 - 60 Hz

19 - 53 Watts
1.6 amp.

Polypropylene

Filtration module

Class 2 - (NFX 15-211 : 2009 standard)

Class 1 - (NFX 15-211 : 2009 standard)

Type 1C

Type 2C

Liquid chemicals
handlings

Liquid chemicals
handlings

Type 1P 1C

Type 1P 2C

Liquid chemicals
and powders
handlings

Liquid chemicals
and powders
handlings

Type 1C 1P

Type 2C 1P

Liquid chemicals
and powders
handlings in clean
room

Liquid chemicals
and powders
handlings in clean
room
Molecular filter

Equipments

H14 HEPA filter

Types of filters available

Standard Equipment

Options

GF4 AS For organic vapours

Air flow meter

Permanent air face velocity monitoring


system

Molecode S*

Automatic alarm to detect filter saturation by solvents according to


NF X 15 211 : 2009 standard (*compulsory for class 1 configuration)

Flow monitor

Permanent ventilation control device


according to EN 14175-2:2003 standard

Work surface #1

Tempered glass work surface with seeled frame

GF4 F

For formaldehyde vapours

Work surface # 2

In phenolic resin with built-in retention tray

GF4 K

For ammonia vapours

Internal lighting

Compact tubular fluorescent lighting 18 Watts - 500 Lux - IP 67

Benchcap

Fixed work bench made of anti-corrosion metallic alloy

Sampling port

For filter saturation detection (N/A if


Molecode S installed)

Adjustable slinding shelf for Mobicap and Benchcap

Programmable timer

Timer - 60 hours setting by default according to NFX 15 211: 2009 standard

Energy ports

For the passage of cables

Chemical Listing

List of approved chemicals

Shelf
Transparent back
panel
Access door on
rear panel
Particular
Pre-filter

GF4 BE + For organic vapours + acid vapours

GF4 HP

Compliance to standards

Acrylic
For maintenance interventions
40 % filtration efficiency for particles > 0.3 m

H14 HEPA Filter for powders

AFNOR NF X 15-211:2009 - France


ANSI/ASHRAE 110-1995 - USA
BS 7258 - England
CSA Z316.5 - Canada

ERLAB INC. - 388 Newburyport Turnpike - Rowley, MA 01969 - USA


Phone: 1 (800) 964-4434 - Fax: 1 (978) 948-3354 - e-mail : captairsales@erlab.com

P Please consider the environment before printing this document.

CE Marking
NF P.92.507 (Acrylic part)
EN 1822 : 1998 (H14 HEPA filter )

w w w. c ap t a i r. c o m

08/2010 - Technical data are not contractual. Erlab reserves the right to modify the present document without prior notice.

Specifications

Dimensions (inches)
External dimensions

481
27

50 1/4

20

53 max
45 3/4 min

34

26 3/4

6 1/2

3
10 1/2

10 1/4

7 1/2

10 1/8

46 1/2

21 1/2
24 3/4
* Total height according to filtration column type (in)
Type 1C
Type 1P 1C
Type 1C 1P

45 3/4
49 1/2
49 1/2

Type 2C
Type 1P 2C
Type 2C 1P

49 1/2
53
53

ERLAB INC. - 388 Newburyport Turnpike - Rowley, MA 01969 - USA


Phone: 1 (800) 964-4434 - Fax: 1 (978) 948-3354 - e-mail : captairsales@erlab.com

P Please consider the environment before printing this document.

w w w. c ap t a i r. c o m

08/2010 - Technical data are not contractual. Erlab reserves the right to modify the present document without prior notice.

Mobile ductless filtration fume hood for personal protection


during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter
and particulate filtration on H14 HEPA filter.

481

Work surface #1

Mobile ductless filtration fume hood for personal protection


during handlings of liquid, gaseous and solid chemicals.
Molecular filtration by adsorption on activated carbon filter
and particulate filtration on H14 HEPA filter.

48 7/8

17 7/8

46 1/4

Work surface #2

46 1/4
20

1 1/2

43 1/2

ERLAB INC. - 388 Newburyport Turnpike - Rowley, MA 01969 - USA


Phone: 1 (800) 964-4434 - Fax: 1 (978) 948-3354 - e-mail : captairsales@erlab.com

P Please consider the environment before printing this document.

w w w. c ap t a i r. c o m

08/2010 - Technical data are not contractual. Erlab reserves the right to modify the present document without prior notice.

2 3/8

Você também pode gostar