Anton Paar ProveTec Product Lines

Master of Standards

Testing Instruments for the Hydrocarbon World.

ASTM D 5 | ASTM D 36 | ASTM D 56 | ASTM D 70 | ASTM D 86 | ASTM D 92 | ASTM


ASTM D 97 | ASTM D 113 | ASTM D 130 | ASTM D 189 | ASTM D 217 | ASTM D 287 | A
ASTM D 446 | ASTM D 473 | ASTM D 524 | ASTM D 525 | ASTM D 665 | ASTM D 850 | A
ASTM D 942 | ASTM D 943 | ASTM D 1078 | ASTM D 1298 | ASTM D 1319 | ASTM D 132
D 1481 | ASTM D 2111 | ASTM D 2170 | ASTM D 2274 | ASTM D 2500 | ASTM D 3142
D 3934 | ASTM D 3941 | ASTM D 4310 | ASTM D 5534 | ASTM D 5853 | ASTM D 6082
D 6371 | ASTM D 7462 | ASTM D 7525 | ASTM D 7545 | ASTM E 28 | DIN 51 551-1 | DIN
51 587 | DIN 51 755-1 | DIN 51 757 | DIN 51 784 | DIN 51 794 | DIN 51 808 | DIN 51 81
EN 924 | EN 1238 | EN 1426 | EN 1427 | EN 12 593 | EN 12 595 | EN 13 179-1 | EN 13 3
EN 14 522 | EN 15 751 | EN 16 091 | EN 23 015 | FTM 141-4293 | FTM 791-201 | FTM
FTM 791-1101 | FTM 791-1102 FTM 791-1103 | FTM 791-3002 | FTM 791-3302 | FTM
3453 | FTM 791-3703 | FTM 791-4011 | FTM 791-5001 | FTM 791-5002 | FTM 791-530
13 IP 14 | IP 15 | IP 34 | IP 36 | IP 40 | IP 49 | IP 50 | IP 53 | IP 58 | IP 69 | IP 71 | IP 80 |
| IP 142 | IP 146 | IP 154 | IP 156 | IP 157 | IP 160 | IP 170 | IP 179 | IP 189 | IP 190 | IP 1
319 | IP 376 | IP 388 | IP 441 | IP 491 | IP 492 | IP 515 | IP 516 | IP 520 | IP 540 | ISO 1516
2719 | ISO 3007 | ISO 3015 | ISO 3016 | ISO 3104 | ISO 3105 | ISO 3405 | ISO 3675 | ISO
| ISO 4263 | ISO 4625 | ISO 6246 | ISO 6247 | ISO 6614 | ISO 6615 | ISO 7120 | ISO 7536
JIS C2101 | JIS K2207 | JIS K2220 | JIS K2235 | JIS K2249 | JIS K2254 | JIS K2258 |
JIS K2265-4 | JIS K2269 | JIS K2270 | JIS K2276 | JIS K2283 | JIS K2287 | JIS K2288 |
K2518 | JIS K2536 | JIS K2601 | AASHTO T48 | AASHTO T51 | AASHTO T53 | AASHTO
79/831/EWG | CEI 79-4 | DAB 10-V.5.8.1 | NAC TM0172-2001 | SMS 65
Anton Paar Headquarters

Sales Subsidiaries

Competence in
Standardized
Measurement

Sales Partners and Joint Ventures

AASHTO American Association of State Highway &


Transportation Officials
ASTM American Society for Testing & Materials
DIN Deutsches Institut fr Normung
EN Comit Europen de Normalisation

Index
Volatility
``
Flammability

D 93-A | ASTM D 93-B | ASTM D 93-C


ASTM D 323 | ASTM D 381 ASTM D 445
ASTM D 873 ASTM D 892 ASTM D 937
21 ASTM D 1401 | ASTM D 1403 | ASTM
| ASTM D 3230 | ASTM D 3603 | ASTM
| ASTM D 6084 | ASTM D 6184 | ASTM
N 51 562 | DIN 51 579 | DIN 51 580 | DIN
17 | DIN 52 004 | DIN 52 013 | EN 116 |
398 | EN 13 589 | EN 13 703 | EN 14 112
791-305 | FTM 791-313 | FTM 791-321
M 791-3352 | FTM 791-3354 | FTM 79108 | FTM 791-5315 | FTM 791-5325 | IP
IP 121 | IP 123 | IP 131 | IP 135 | IP 138
195 | IP 219 | IP 265 | IP 309 | IP 310 | IP
6 | ISO 1523 | ISO 2137 | ISO 2592 | ISO
O 3735 | ISO 3837 | ISO 3838 | ISO 4262
6 | ISO 12 205 | ISO 13 736 | ISO 15 267
JIS K2261 | JIS K2265-1 | JIS K2265-3
JIS K2510 | JIS K2513 | JIS K2514 | JIS
O T73 | AASHTO T172 | AASHTO T300
58 | Superpave | VV-L-791e-5314

IEC International Electrotechnical Commission


IP Institute of Petroleum Standards
ISO International Standardization Organisation
JIS Japanese Industrial Standards Committee

4-6

``
Distillation

``
Vapor Pressure

Oxidation Stability

Cold Flow Properties

8-9

10

Consistency & Ductility

11 - 13

Various Petroleum Properties

14 - 19

``
Liquids

14

``
Fuels

14 - 16

``
Lubricants

17 - 18

``
Greases

Accessories

FTM Federal Test Method (US)

4-7

18

19

Volatility - Flammability
Pensky-Martens Flash Point Tester:
PMA5
The automatic closed cup flash point tester
PMA5 detects the flash point at the lowest
temperature corrected to a barometric
pressure of 101.3 kPa at which application
of an ignition source causes the vapors
of a specimen of a sample to ignite under
specified conditions of test.
Suitable for biodiesel (FAME) & blends,
distillate fuels (diesel, kerosine, heating
oil, turbine fuels), lubricating oils and other
homogeneous petroleum liquids.

Specifications
Datasheet:
12-5770.pdf (PMA 5)
Reference:
12-5770 / 107125 (115/230 V, EU)
12-5771 / 107126 (115/230 V, US)
Temperature range:
ambient to +405 C (+761 F)

Standard methods:
ASTM D 93-A+B+C, ISO 2719-A+B+C,
JIS K2265-3, IP 34-A+B+C

Pensky-Martens Flash Point Tester


with Sample Changer: PMA4SC
Datasheet:
12-2772.pdf (PMA 4 SC)
Reference:
12-2772 / 107121 (115/230 V, EU)
12-2773 / 108322 (115/230 V, US)
Temperature range:
ambient to +405 C (+761 F)

Cleveland Flash & Fire Point Tester:


CLA5
The automatic open cup flash & fire point
tester CLA5 measures the flash point and
fire point of petroleum products.
It is applicable to all petroleum products
with flash point above 79 C (175 F) and
below 400 C (752 F) including bitumen.
Except fuel oils.
Standard methods:
ASTM D 92, ISO 2592, EN 22592,
JIS K2265-4, AASHTO T48, FTM 791-1103,
IP 36

Datasheet:
12-5700.pdf (CLA 5)
Reference:
12-5700 / 107122 (115/230 V, EU)
12-5701 / 107123 (115/230 V, US)
Temperature range:
+79 C to +400 C (+175 to +752 F)

PMA4SC is an exceptionally time and


cost saving alternative. The PMA4 with
sample changer carrousel can carrying up
to 12 test cups.
The instrument is equipped with a fire
extinguishing system. It is still small enough
to fit into a fume-hood.
Standard methods:
ASTM D 93-A+B+C, ISO 2719-A+B+C,
JIS K2265-3, IP 34-A+B+C

Volatility - Flammability

Specifications
Datasheet:
12-0501.pdf (ABA 4)
Reference: internal air cooling
12-0501 / 107097 (115/230 V, EU)
12-0502 / 108319 (115/230 V, US)
Reference: external liquid cooling
12-0503 / 107098 (115/230 V, EU)
12-0504 / 108320 (115/230 V, US)
Temp. range: internal air cooling
+10 C to +110 C (+50 to +230 F)
Temp. range: external liquid cooling
-30 C to +110 C (-22 to +230 F)

Abel Flash Point Tester:


ABA4
The automatic closed cup flash point
tester ABA4 measures the flash point of
petroleum liquid products and other liquids
having flash points between -30 C and
+110 C.
The equilibrium-method measures the
flash/no flash temperature of paints,
varnishes, paint binders, solvents,
adhesives, petroleum & related products
between -30 C and +110 C.
Standard methods:
ISO 13 736, ISO 1516, ISO 1523, EN 924,
DIN 51 755-1, IP 170, IP 491, IP 492

TAG Flash Point Tester:


TAG4
The automatic closed cup flash point
tester TAG4 measures the flash point of
petroleum liquids and other liquids having
flash points between -30 C and +110 C.
Suitable for kerosine, jet fuel, solvent,
chemicals.
Standard methods:
ASTM D 56, ASTM D 3934, ASTM D 3941,
ISO 1516, ISO 1523, EN 924, JIS K2265-1,
FTM 791-1101, IP 304, IP 491, IP 492

Datasheet:
12-0540.pdf (TAG 4)
Reference: internal air cooling
12-0540 / 107099 (115/230 V, EU)
12-0541 / 107100 (115/230 V, US)
Reference: external liquid cooling
12-0542 / 107101 (115/230 V, EU)
12-0543 / 108321 (115/230 V, US)
Temp. range: internal air cooling
0 C to +110 C (+32 to +230 F)
Temp. range: external liquid cooling
-30 C to +110 C (-22 to +230 F)

Pensky-Martens Flash Point Tester:


PM4
Datasheet:
12-1650.pdf (PM 4)
Reference:
12-1650 / 107149 (230 V)
12-1651 / 107150 (115 V)
Temperature range:
+40 C to +350 C (+104 to +662 F)

The semi-automatic closed cup flash point


tester PM4 measures the flash point at the
lowest temperature at which application
of an ignition source causes the vapors
of a specimen of a sample to ignite under
specified conditions of test.
Standard methods:
ASTM D 93-A+B, ISO 15 267, ISO 2719-A+B,
JIS K2265-3, AASHTO T73, AASHTO T172,
FTM 141-4293, FTM 791-1102, IP 34-A+B,

Volatility - Flammability
Cleveland Flash & Fire Point Tester:
CL5
The semi-automatic open cup flash and
fire point tester CL5 can measure the
flash and fire point acc. to the Cleveland
method. It is suitable for petroleum
products and other liquids including
bitumen with an expected flash & fire point
in the range of +79 C to +400 C
(+175 F to +752 F).

Specifications
Datasheet:
12-2730.pdf (CL 5)
Reference:
12-2730 / 107152 (230 V)
12-2731 / 107153 (115 V)
Temperature range:
+79 C to +400 C (+175 to +752 F)

Standard methods:
ASTM D 92, ISO 2592, JIS K2265-4,
AASHTO T48, FTM 791-1103, IP 36

Abel Flash Point Tester:


AB5
Datasheet:
12-2270.pdf (AB 5)
Reference:
12-2270 / 107151 (230 V)
Measuring range:
up to +70 C (up to +158 F)

Auto-Ignition Temperature Tester:


ZPA3

The ZPA3 enables automatically a


classification to safety aspects by
measuring the tendency of substances to
ignite themselves when getting contact
with hot objects.
Suitable for liquids. A special program
allows to examine pasty or solid matter,
too.
Available with or without heated samplefeeding device.

Datasheet:
12-1822.pdf (ZPA 3)

Standard methods:
EN 14 522, EN 60 079, CEI 79-4, DIN 51 794,
IEC 60079, VDE 0170, 79/831/EWG

Temperature range:
ambient to +650 C (+1202 F)

Reference: with sample-feeder


12-1822 / 107115 (230 V)
12-1823 / 110237 (115 V)
Reference: without sample-feeder
12-1800 / 130641 (230 V)
12-1801 / 130642 (115 V)

The semi-automatic closed cup flash point


tester AB5 can measure the flash point of
petroleum products and other liquids with
flash points up to +70 C (up to +158 F).
Standard methods:
ISO 13 736, IP 170

Volatility - Distillation & Vapor Pressure

Specifications
Datasheet:
11-5580.pdf (ADU 4+)
Reference:
11-5580 / 106515 (230 V)
11-5582 / 106516 (230V, Dry Point)
Working range:
0 C to +450 C (+32 F to +842 F)
Distillation groups:
1 to 4, solvents

Distillation at Atmospheric
Pressure: ADU 4+
The ADU 4+ automatically performs
distillation tests of petroleum products
as well as aromatic hydrocarbons and
other volatile organic liquids featuring an
automated fire extinguishing system.
Options:
ADU4+Dry Point with automatic dry point
detection.
Standard methods:
ASTM D 86, ASTM D 850, ASTM D 1078,
ISO 3405, JIS K2254, IP 123, IP 195

Distillation at Atmospheric
Pressure: DU4 Eco & Pro
For the manual distillation of petroleum
products as well as aromatic hydrocarbons
and other volatile organic liquids.

Datasheet:
11-0904.pdf (DU 4 Eco)
11-0910.pdf (DU 4 Pro)

Options:
``DU4 EcoPlus
``DU4 EcoThermoPlus
``DU4 Pro
``DU4 ProThermo

Reference:
11-0904 / 106509
11-0905 / 108315
11-0906 / 106510
11-0907 / 106511
11-0910 / 106512
11-0911 / 106513
11-0912 / 106514
11-0913 / 108316

Standard methods:
ASTM D 86, ASTM D 850, ASTM D 1078,
ISO 3405, JIS K2254, IP 123, IP 195

(230 V, Eco+)
(115 V, Eco+)
(230 V, EcoThermo+)
(115 V, EcoThermo+)
(230 V, Pro)
(115 V, Pro)
(230 V, ProThermo)
(115 V, ProThermo)

Distillation groups:
1 to 4, solvents (up to 400 C)

REID Vapor Pressure:


RVP
Datasheet:
13-0201_digital.pdf (RVP)
13-0201_analog.pdf (RVP)
Reference:
13-0201 / 107034 (vessel <180 bar)
13-0202 / 107035 (vessel >180 bar)
13-2250 / 107021 (manometer)
17-0210 / 106583 (230 V, 6-place bath)
13-0215 / 106542 (230 V, 3-place bath)

The RVP is used for the determination of


vapor pressure of gasoline, volatile crude
oil and other volatile petroleum products.
It is a modular system to be composed of
RElD-Vapor Pressure Vessels (with 2 valves
or valveless), analog or digital PA-REID
manometers and a liquid bath.
Standard methods:
ASTM D 323-A+C+D, ISO 3007-A+C+D,
JIS K2258, IP 69-A+C+D

Temperature range:
+79 C to +400 C (+175 to +752 F)

Oxidation Stability
Rapid Small Scale Oxidation Test
(RSSOT): PetroOxy
The automatic PetroOxy initiates a very
fast artificial aging process to evaluate the
oxidation stability of liquid fuels (gasoline,
diesel, biodiesel/FAME & blends). The
results include all volatile & non-volatile
oxidation products, thereby provide
a complete analysis of the sample's
oxidation stability in a short time period.
Standard methods:
ASTM D 7525 (Gasoline)
ASTM D 7545 (Diesel, Biodiesel & Blends)
EN 16 091 (Diesel, Biodiesel (FAME) & Blends)

Specifications
Datasheet:
13-3002.pdf (PetroOxy Block)
13-3006.pdf (PetroOxy Peltier)
Reference:
13-3002 / 107131 (115/230 V, EU)
13-3003 / 107132 (115/230 V, US)
Reference: Active Cool
13-3006 / 107133 (115/230 V, EU, Peltier)
13-3007 / 107134 (115/230 V, US, Peltier)

Rapid Small Scale Oxidation Test


(RSSOT): PetroOxy Steel
Datasheet:
13-3008.pdf (PetroOxy S Block)
13-3016.pdf (PetroOxy S Peltier)
Reference:
13-3008 / 107135 (115/230 V, EU)
13-3009 / 107136 (115/230 V, US)
Reference: Active Cool
13-3016 / 108338 (115/230 V, EU, Peltier)
13-3017 / 108339 (115/230 V, US, Peltier)

Oxidation Stability of Gasoline and


Aviation Fuels: OBA1
The semi-automatic OBA1 is used for fuels
to determine the stability (induction period)
and the tendency to form gum (potential
residue) under accelerated oxidation
conditions.
Programmable PA5-OBA manometers on
stainless steel oxidation vessels are available
in combination with a liquid bath as OBA1
or as OBA1/T with a dry heat bath.
Standard methods:
ASTM D 525, ASTM D 873, ISO 7536,
JIS K2276, JIS K2287, FTM 791-3352,
FTM 791-3354, IP 40, IP 138

Datasheet:
13-1660.pdf (OBA 1)
Reference: OBA1
13-1660 / 107052 (230 V, liquid)
13-1661 / 107053 (115 V, liquid)
Reference: OBA1/T
13-1662 / 107054 (230 V, dry heat)
13-1663 / 107055 (115 V, dry heat)
Test places:
1-4

The automatic PetroOxy with stainless


steel chamber initiates a very fast artificial
aging process to evaluate the oxidation
stability of natural oils/fats, food &
cosmetics and water containing products.
The PetroOxy is cost saving due to a
massive reduction of test time, improved
repeatability and small sample volumen.
The PetroOxy requires manual re-cooling
between tests by an externally chilled
cooling block.
While the PetroOxy Active Cool with
Peltier elements will re-cool automatically.
Especially recommended for low boiling
liquids.

Oxidation Stability

Specifications
Datasheet:
13-1664.pdf (OBA 2)
Reference: OBA2
13-1664 / 108333 (230 V, liquid)
13-1665 / 108334 (115 V, liquid)
Reference: OBA2/T
13-1666 / 107056 (230 V, dry heat)
13-1667 / 108335 (115 V, dry heat)
Test places:
1-4

Oxidation Stability of Gasoline and


Aviation Fuels: OBA2
The semi-automatic OBA2 safety arrangement has special features to comply with
German safety regulations to avoid healthhazards caused by unexpected explosions
as much as possible and also protect the
expensive pressure sensors.
The programmable PA5-OBA manometers
on the stainless steel oxidation vessels are
available with a liquid bath as OBA2 or as
OBA2/T with a dry heat bath.
Standard methods:
ASTM D 525, ASTM D 873, ISO 7536,
JIS K2276, JIS K2287, FTM 791-3352,
FTM 791-3354, IP 40, IP 138

Oxidation Characteristics:
TOST/TOO
The modular TOST bath is used for testing
the oxidation characteristics of various
petroleum products.
Standardized glassware sets and
accessories are available.
Options:
``4 place liquid bath
``4 place dry heat bath
Standard methods:
ASTM D 943, ASTM D 2274, ASTM D 4310,
ASTM D 7462, ISO 12 205, ISO 4263-1,
ISO 4263-2, ISO 4263-3, JIS C2101,
JIS K2514, DIN 51 587, FTM 791-5308, IP 157,
IP 388

Datasheets:
16-0586_ASTM943.pdf (TOST)
16-0586_ASTM2274.pdf (TOST)
16-0586_ASTM4310.pdf (TOST)
16-0586_ISO12205.pdf (TOST)
16-0586_ISO4263.pdf (TOST)
16-0586_DIN51587.pdf (TOST)
16-0545.pdf (TOO)
Reference:
16-0583 / 106563 (230 V)
16-0584 / 106564 (115 V)
Test places:
1-4

Oxidation Stability of Lubricating


Greases: OFA2
Datasheet:
17-0212.pdf (OFA 2)
Reference:
17-0212 / 107088 (oxidation vessel)
17-1210 / 107030 (manometer)
17-0210 / 106583 (230 V, liquid bath)
13-1672 / 106555 (230 V, dry heat bath)
Test places:
1-4

The semi-automatic OFA2 arrangement


may be used for quality control to indicate
batch-to-batch conformity of lubricating
greases stored in an oxygen atmosphere
in a sealed system at an elevated
temperature.
The programmable PA5-OFA manometer
shall be combined with the stainless steel
oxidation vessel and a liquid bath or dry
heat bath.
Standard methods:
ASTM D 942, JIS K2220, DIN 51 808,
FTM 791-3453, IP 142, VV-L-791e-5314

Cold Flow Properties


Cold Filter Plugging Point:
CFPPI
The cold filter plugging point test
determinates the lowest temperature at
which a fuel will give trouble free flow
in certain fuel systems. It is defined as
highest temperature at which a given
volume of fuel fails to pass through a
standardized filtration device in a specified
time when cooled under the conditions
prescribed in the test method.
A system of a metal-block cryostat with
a 4-place cooling chamber provides the
required cooling temperature.

Specifications
Datasheet:
13-2418.pdf (CFPP I)
Reference:
13-2418 / 107162 (230 V)
Working range:
down to -34 C
Test places:
1 chamber (4 places)

Standard methods:
ASTM D 6371, EN 116, JIS K2288, IP 309

Cloud & Pour Point:


CAPPI
Datasheet:
16-2372.pdf (CAPP I)
Reference:
16-2372 / 106533 (230 V, 1 bath)
Working range:
+20 C to -69 C
Chamber temperatures:
0 C to -69 C
Test places:
1 chamber (4 places)

Cloud & Pour Point:


CAPPIV & V
Designed for an easy workflow, the
CAPPIV&V with independently set
of cooling chambers allows an instant
transfer of the sample jar to the next lower
chamber temperature.
Suitable for any petroleum products.
Standard methods:
ASTM D 97, ASTM D 2500, ASTM D 5853,
ISO 3015, ISO 3016, EN 23 015, JIS K2269,
JIS K2601, FTM 791-201, IP 15, IP 219, IP 441

Datasheet:
16-2378.pdf (CAPP IV)
16-2360.pdf (CAPP V)
Reference:
16-2378 / 107029 (230 V, 4 bath)
16-2360 / 106532 (230 V, 5 bath)
Working range:
+20 C to -69 C
Chamber temperatures:
0 C, -18 C, -33 C, -51 C, -69 C
Test places:
4 or 5 chambers (4 places each)

10

The CAPPI is a metal-block cryostat


designed to perform the cloud point test.
It is the temperature at which a fuel starts
becoming cloudy or begins to precipitate
paraffin. The pour point is the lowest
temperature at which movement of the test
sample is observed.
Suitable for any petroleum products.
Standard methods:
ASTM D 97, ASTM D 2500, ASTM D 5853,
ISO 3015, ISO 3016, EN 23 015, JIS K2269,
JIS K2601, FTM 791-201, IP 15, IP 219, IP 441

Consistency & Ductility

Specifications
Datasheet:
18-1120.pdf (PNR 12)
18-1120_Bitumen.pdf (PNR)
18-1120_Grease.pdf (PNR)
Reference:
18-1120 / 106813 (100-240 V, EU)
18-1121 / 106814 (100-240 V, US)
Measuring range:
0 mm up to 65 mm
Maximum test load:
2000 g

Penetration:
Penetrometer PNR12
The PNR12 measures automatically the
resistance a material provides against being
pierced by specifically shaped penetrator
(needle, cone, rod, disk & others). Storage
of last 200 measurements, statistic, data
transfer to USB Stick, data conversion
and cone to solid cone, NLGI class, EN
bitumen class. Test kits for: greases, waxes,
food, cosmetics, pharmaceuticals, etc.
Standard methods:
ASTM D 5, ASTM D 217, ASTM D 937,
ASTM D 1321, ASTM D 1403, ASTM D 7342,
ISO 2137, EN 1426, EN 13 880-3,
European Pharmacopoea 2.9.9., DIN 51 579

Fully Automatic Surface-Detection:


Force-Sensor-Plungers
The Force-Sensor-Plunger will detect the
surface of hard samples even underneath
a layer of water. It starts the standardized
test sequence and reports the results
automatically.
This allows precise adjustment even by
unexperienced staff.
Standard methods:
ASTM D 5, ASTM D 1321, EN 1426,
DIN 51579

Suitable samples:
Immersion depth < 160 penetration
units (16 mm) for bitumen, waxes,
and other comparable hard samples
Force-sensor-plungers:
47.5 g for 1 additional weight
97.5 g for 1 additional weight
97.5 g for 1 to 4 additional weights
(Load weights of 10 g, 50 g or 100 g
can be added.)
Test kits:
18-2223 / 106929
18-2225 / 106931

Shear Stability of Grease:


Grease Worker
Datasheet:
17-1506.pdf (Grease Worker)
Reference:
17-1506 / 106763 (230 V)
17-1505 / 106762 (115 V)
Test places:
1-2
Speed:
60 strokes/min

Suitable for shear stability test preparation


of greases and other semi solid materials.
This automatic instrument simplifies the
very exhausting grease working procedure.
The machine is suitable for either single or
double-worker operation. Equipped with
an stroke counter, that can be preset and
will stop the machine automatically.
Standard methods:
ASTM D 217, ISO 2137, JIS K2220,
FTM 791-313, IP 50

11

Consistency & Ductility


Softening Point Ring & Ball:
RKA5

Specifications

The RKA5 with its different ball centering


& dispensing devices determines
automatically the temperature at which a
substance attains a particular degree of
softness. A temperature heating rate chart
for conformity check of each test will be
displayed.
Suitable for bitumen, paint & varnish
binders and resins, etc.

Datasheet:
10-0800.pdf (RKA 5)

Standard methods:
ASTM D 36, ASTM E 28, ISO 4625-1, EN 1238,
EN 1427, EN 13 179-1, JIS K2207,
AASHTO T53, IP 58,

Test places:
2 (simultaneous)

Reference:
10-0800 / 106209 (230 V)
10-0801 / 106210 (115 V)
Working range:
up to 250 C

RKA5 Options
Reference:
10-0851

Reference:
10-0860 / 10-0864

Fraass Breaking Point:


BPA5
The BPA5 determines automatically
the brittle behavior of bitumen at low
temperatures. A thin flat steel plaque,
coated with the sample, is flexed under
specified conditions at a descending series
of temperatures. The Fraass Breaking
Point is the temperature at which the first
cracks appear in the coating. Optinal with
permanent bending program and BPAConsoftware for other non-standardized
application of different coatings.
Standard methods:
EN 12 593, JIS K2207, IP 80

12

Datasheet:
10-0457.pdf (BPA 5)
Reference:
without cooler
10-0457 / 106195
10-0458 / 108313
with cooler
10-0460 / 106196
10-0461 / 106197

(230 V)
(115 V)
(230 V)
(115 V)

Working Range (depends on cooler):


approx. -45 C to +60 C

Automatic electromagnetic ball


dispense
A standard test rack & centering guides
in combination with two electromagnetic
holders for automatic ball dispens after
15 min; recommendable for softening
points >80 C.
Wilhelmi Method
EN 1871-F, DIN 1996-15

Consistency & Ductility

Specifications
Datasheet:
10-0360.pdf (DDA 3)
Reference:
10-0360 / 106178 (230 V, 100 cm)
10-0361 / 106179 (115 V, 100 cm)
10-0364 / 106180 (230 V, 150 cm)
10-0365 / 108312 (115 V, 150 cm)
Working range:
approx. -10 C to +60 C
Test places:
3 (simultaneous)

Tensile Properties:
Force-Ductilitymeter DDA3
The DDA3 with double walled fully isolated,
isothermal jacket bath for very even and
exact temperature adjustment of the bitumen
samples. Automatic rupture detection above
a force of 20 mN. A optional DDAConSoftware with a special research program
section for recording, saving and graphic
presentation of the results is available.
Standard methods:
Elongation: ASTM D 113, JIS K2207,
AASHTO T51, DIN 52013
Recovery: ASTM D 6084, EN 13 398, IP 516
Force: EN 13 589, EN 13 703, AASHTO T300,
IP 515, IP 520

Details of DDA 3
Ductility/Elongation:
The distance to which a sample will
elongate before breaking is measured.
Elastic Recovery
The recoverable strain will be determined.
This is useful in confirming that a material
has been added to the asphalt to provide a
significant elastomeric characteristic.
Force Ductility:
The tensile properties and deformation
energy is measured on the basis of the
performed force and the specimen strain.

Travel length:
100 cm or 150 cm
Traction speed:
2.5 mm/min to 140 mm/min
(stepless)
Automatic rupture detection:
above 20 mN
Maximum Force:
300 N

Tensile Properties:
Ductilitymeter DD3
Datasheet:
10-0350.pdf (DD 3)

10-0350 / 106176
10-0351 / 108310
10-0354 / 106177
10-0355 / 108311

Reference:
(230 V, 100 cm)
(115 V, 100 cm)
(230 V, 150 cm)
(115 V, 150 cm)

Working range:
approx. -10 C to +60 C
Test places:
3 (simultaneous)

The semi-automatic DD3 is suitable


to measure the ductility (elongation)
of bitumen. In this case a briquette is
pulled apart in a water bath at a defined
temperature (mostly 25 C) until it ruptures.
The other method is the elastic recovery
test.
Available travelling length 100 or 150 cm.
Delivered with thermometers and printer.
Standard methods:
Elongation: ASTM D 113, JIS K2207,
AASHTO T51, DIN 52 013
Recovery: ASTM D 6084, EN 13 398, IP 516

13

Various Petroleum Properties - Liquids & Fuels


Density, API & Specific Gravity:
Tempering Bath
Full view borosilicate bath suitable for the
determination of density, specific & API
gravity with hydrometers or pycnometers.
Standardized accessories are available.
Standard methods:
ASTM D 70, ASTM D 287, ASTM D 1298,
ASTM D 1481, ASTM D 2111, ASTM D 3142,
ISO 3675, ISO 3838, JIS K2249, DIN 51 757,
DIN 52 004, IP 160, IP 189, IP 190

Specifications
Datasheet:
26-0017.pdf (Tempering Bath)
Reference:
26-0017 / 106599 (230 V)
26-0018 / 106600 (115 V)
Working range:
ambient to +150 C
Test places:
4

Kinematic Viscosity:
Viscobath
Datasheet:
20-0120.pdf (Viscobath)
Reference:
20-0120 / 110234 (230 V)
Working range:
up to +230 C (446 F)
Test places:
7

Gum Content:
Jet Evaporation Tester GUM
Gum content is the residue of aircraft fuels
motor gasoline and other volatile destillates
which cannot be evaporated.
Available in different versions for tests with
air or steam supply or with air supply only.
Both versions with safety multifunction
head for simultaneous positioning of all
5pre-adjusted inlet tubes into pre-heating
or working position.
Standard methods:
ASTM D 381, ISO 6246, JIS K2261,
DIN 51 784, FTM 791-3302, IP 131, IP 540

14

Datasheet:
13-0035.pdf (GUM air & steam)
13-2030.pdf (GUM air)
Reference:
13-0035 / 106537 (230 V, air & steam)
13-2030 / 106556 (230 V, air)
13-2031 / 106557 (115 V, air)
Working range:
up to +280 C (air & steam)
up to +246 C (air)
Test places:
5

Tempering bath for the determination of


the kinematic viscosity with viscometers of
Ubbelohde, Cannon-Fenske or BS/IP-UTube type.
Standardized accessories are available.
Standard methods:
ASTM D 445, ASTM D 446, ASTM D 2170,
ISO 3104, ISO 3105, EN 12 595, JIS K2207,
JIS K2283, FTM 791-305, IP 71-1+2 , IP 319

Various Petroleum Properties - Fuels

Specifications
Datasheet:
13-0930.pdf (FIA)
Reference:
13-0930 / 107158 (230 V)
13-0929 / 107157 (115 V)

Fluorescent Indicator Adsorption:


FIA
For the determination of hydrocarbon
types in liquid petroleum products.
Standard methods:
ASTM D 1319, ISO 3837, JIS K2536,
FTM 791-3703, IP 156

Test places:
4

Corrosiveness to Copper:
Copper Strip Tester
To determine the corrosiveness to copper
of aviation gasoline, aviation turbine fuel,
automotive gasoline, natural gasoline or
other hydrocarbons, cleaners solvent,
kerosene, diesel fuel, distillate fuel oil,
lubricating oil, and other various petroleum
products.
Standard methods:
ASTM D 130, ISO 2160, JIS K2220, JIS K2513,
FTM 791-5325, IP 154

Datasheet:
13-0700.pdf (Copper Strip Tester)
Reference:
13-0700 / 107156 (230 V)
13-0699 / 106544 (115 V)
Working range:
ambient to +200 C
Test places:
4

Option silver strip test:


ASTM D 4814

Ramsbottom Carbon Residue


Tester: RCRT
Datasheet:
13-0870.pdf (RCRT)
Reference:
13-0870 / 107327 (230 V)
13-0871 / 107328 (115 V)
Working range:
ambient to +760 C
Test places:
5

The semi-automatic RCRT with it's


gas-free furnace, indicates coke-forming
properties by determing the amount of
carbon residue left after evaporation and
pyrolysis of an oil sample.
Applicable to relatively non-volatile
petroleum products, which partially
decompose on distillation at atmospheric
pressure, like diesel fuel, motor oil, gas or
crude oil.
Standard methods:
ASTM D 524, ISO 4262, FTM 791-5002, IP 14

15

Various Petroleum Properties - Fuels


Conradson Carbon Residue Tester:
CCRT
The manual CCRT serves as a rough
indication of the tendency of a fuel or oil
to form coking deposits. It is available for
different kinds of gas supply.
Standard methods:
ASTM D 189, ISO 6615, JIS K2270,
DIN 51 551-1, FTM 791-5001, IP 13

Specifications
Datasheet:
13-0841.pdf (CCRT)
Reference:
13-0841 / 106547 (municipal gas)
13-0842 / 106548 (butane/propane)
13-0843 / 106549 (natural gas)
Test places:
1

Salts in Crude Oil:


Salinometer SCO1
Datasheet:
13-0497.pdf (SCO 1)
Reference:
13-0497 / 107129 (230 V)
13-0496 / 107128 (115 V)

The conductivity method covers the


determination of the approximate chloride
(salt) concentration in crude oil.
SCO1 is a laboratory bench model that,
for operator's protection, can be actuated
by two-hand use only. The knowledge of
the concentration gives advice concerning
the need of crude oil desalting and the
efficiency of the process desalter. The
corrosion rates in refining units depended
on the concentration.
Standard methods:
ASTM D 3230, JIS K2601, IP 265

Sediment in Crude & Fuel Oil:


Extraction System
The extraction system is used for the
determination of sediment in crude oils and
fuel oils by extraction with toluene.
Standard methods:
ASTM D 473, ISO 3735, FTM 791-3002, IP 53

16

Datasheet:
13-0321.pdf (Extraction)
Reference:
13-0321 / 106715

Various Petroleum Properties - Lubricants

Specifications
Datasheet:
16-2600.pdf (DH 5)
Reference:
16-2600 / 106755 (230 V)
16-2601 / 108373 (115 V)

Demulsibility Characteristics:
Herschel Tester DH5
The semi-automatic DH5 serves to
measure the ability of petroleum oils or
synthetic fluids to separate from water.
Standard methods:
ASTM D 1401, ISO 6614

Working range:
ambient to +85 C
Test places:
8 test & 2 pre-tempering places
Stirrer speed:
500 rpm to 1600 rpm

Foaming Characteristics:
Foam Tester
For the determination of the foaming
characteristics of lubricating oils.
For a more convenient workflow the Foam
Tester is also available as a twin version
with two individually maintained baths.
Standard methods:
ASTM D 892 (sequence I - III), ASTM D 6082
(sequence IV), ISO 6247, JIS K2518, IP 146

Datasheet:
16-1470.pdf (Foam Tester)
Reference:
16-1470 / 106571 (230 V, twin bath)
16-1471 / 108356 (115 V, twin bath)
16-1472 / 106572 (230 V)
16-1473 / 108357 (115 V)
Working range:
+24 C to +150 C
Test places:
4

Corrosion Prevention:
TOR
Datasheet:
16-0724.pdf (TOR)
Reference:
16-0724 / 106566 (230 V)
16-0725 / 106567 (115 V)
Working range:
ambient to +120 C
Test places:
6

The semi-automatic TOR is modular


and can be run according to different
standardized specifications.
It is used to evaluate the rust preventing
characteristics of inhibited mineral oils in
the presence of water.
Standard methods:
ASTM D 665, ASTM D 3603, ASTM D 5534,
ISO 7120, JIS K2510, FTM 791-4011,
FTM 791-5315, IP 135, NACE TM0172-2001

17

Various Petroleum Properties - Lubricants & Greases


Reichert Friction & Wear:
RM 2
Tribology test with a friction & wear tester
with variable rotational speed for the
examination of the load carrying capacity
and wear reducing properties of lubricants
and cutting fluids. The wear surface on
a test roll in mm2 and the time period of
grinding noises are results of the test. The
RM 2 offers different numbers of revolution
per minute (500 to 1500). The test load is
adjustable with weights of 500 g,
1000 g and 1500 g. Test rolls made of
brass, copper, steel and aluminium are
available.

Specifications
Datasheet:
15-0035.pdf (RM 2)
Reference:
15-0035 / 107165 (230 V)
Sample volume:
25 ml
Force:
98 N to 294 N
Test time:
approx. 1 min

Oil Separation of Grease:


Conical Sieve System
Datasheet:
17-0131.pdf (Sieve System)
Reference:
17-0131 / 106720

When lubricating grease separates oil, the


residual material changes in consistency,
which can affect the ability to function as
designed.
The test results correlate with the oil
separation that occure during storage in
pails.
Standard methods:
ASTM D 6184, FTM 791-321

Oil Separation of Grease:


Pressure Filtration System
Useful to measure the stability of
lubricating greases towards oil separation
during storage in cans or drums.
To allow tests at temperatures up to
120C or with aggressive greases this
system is made of stainless steel.
Standard methods:
DIN 51 817, IP 121

18

Datasheet:
17-0140.pdf (Pressure System)
Reference:
17-0140 / 106721

Accessories

Specifications
Datasheet:
26-0400.pdf (Hydrometer)
26-0712.pdf (Pycnometer)
22-0120.pdf (Capillary UAV)
22-0100.pdf (Capillary UDV)
22-0360.pdf (Capillary CUSMV)
22-0000.pdf (Capillary CFRV)
22-0050.pdf (Capillary CFOV)
22-0200.pdf (Capillary BS/IP/RF)
22-0230.pdf (Capillary BS/IP/SL)
22-0400.pdf (Capillary MOV)
22-0530.pdf (Capillary ZCAV)

Accessories: Density & Viscosity


``Hydrometer for bitumen, oil & solvent
ASTM D 287, ASTM D 1298,
ASTM D 2111-A, ASTM D 3142, ISO 3675,
JIS K2249, DIN 51 757-1, IP 160
``Pycnometer for bitumen & oil
Types: Lipkin, Gay-Lussac, Hubbard
ASTM D 70, ASTM D 1481, ISO 3838,
JIS K2249, DIN 51 757-3, DIN 52 004,
IP 189, IP 190.
``Capillary viscosity tubes
Types: Ubbelohde, Cannon-Ubbelohde,
Cannon-Fenske, BS/IP U-Tube,
Ostwald, Zeitfuchs

Accessories: Penetrometer PNR


``Test kits: sets acc. to standard/sample
requirements incl. needle/cone, plunger,
weight, sample container, etc.
``Needles: standard, tapered, pin, VICAT
and certified needles
``Cones & discs: full-, half-, quarterscale-, micro-, hollow-cones and discs
``Rods & rams: rods, rams, cylinders,
cutter, balls, etc.
``Plunger & weight: plunger with or
without automatic surface detection
sensor, additional load weights
``Sample jars & auxiliary equipment:
standard- & grease-jars, wax-cylinders,
centering devices, etc.
``Sample tempering units
``Grease Worker: Micro-Cones

Datasheet:
18-2220.pdf
18-1160.pdf
18-0101.pdf
18-0260.pdf
18-0132.pdf
18-0066.pdf
18-0065.pdf
18-0134.pdf

(PNR Test Kits)


(PNR Needles)
(PNR Cones & Discs)
(PNR Rods & Rams)
(PNR Plunger & Weight)
(PNR Sample Jars etc.)
(PNR Tempering)
(PNR Grease Worker)

Accessories: Verification
Datasheet:
11-0590.pdf (CRM Distillation)
13-0626.pdf (CRM Fuel)
16-1080.pdf (CRM Oil)
24-0551.pdf (CRM Viscosity)
26-0702.pdf (CRM Density)
50-9000.pdf (CRM Flash Point)
50-9121.pdf (CRM Miscellaneous)
40-1001.pdf (Ref. Rust Preventives)
40-1510.pdf (Ref. Fuels & Additives)
40-2002.pdf (Ref. Solid Film Lubricants)
40-3011.pdf (Ref. Antifreeze & Soluble Oil)
40-4010.pdf (Ref. Lubrication & Hydraulic)
40-5010.pdf (Ref. Special Tests)
16-0963.pdf (Thermometer ASTM)
16-0371.pdf (Thermometer IP)

``Certified reference material CRM


for distillation, fuel, oil, viscosity, density,
flash point, etc.
``Metal test specimens
for rust preventives, fuels & fuel
additives, solid film lubricants, antifreeze
& soluble oils, lubricating oils & hydraulic
fluids, special tests
``Thermometers - ASTM / IP
precision made, officially certified,
with or without collar

19

Glossary - Keywords
A

AB5 . . . . . . . . . . . . . . . . . . . . . . . . . . 6
ABA4. . . . . . . . . . . . . . . . . . . . . . . . . . 5
Abel Flash Point. . . . . . . . . . . . . . . . 5, 6
Accessories: Density & Viscosity,
Penetrometer, Verification. . . . . . . . . . 19
ADU 4+ . . . . . . . . . . . . . . . . . . . . . . . . 7
API. . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Atmospheric Pressure . . . . . . . . . . . . . 7
Auto-Ignition Temperature . . . . . . . . . . 6

FIA. . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Filtration System. . . . . . . . . . . . . . . . . 18
Flash & Fire Point. . . . . . . . . . . . . . . 4, 6
Flash Point. . . . . . . . . . . . . . . . . . 4, 5, 6
Fluorescent Indicator Adsorption . . . . 15
Foam Tester. . . . . . . . . . . . . . . . . . . . 17
Force-Ductilitymeter. . . . . . . . . . . . . . 13
Force-Sensor-Plungers. . . . . . . . . . . . 11
Fraass . . . . . . . . . . . . . . . . . . . . . . . . 12
Friction & Wear. . . . . . . . . . . . . . . . . . 18

Ramsbottom . . . . . . . . . . . . . . . . . . . 15
Rapid Small Scale Oxidation. . . . . . . . . 8
RCRT. . . . . . . . . . . . . . . . . . . . . . . . . 15
Reichert. . . . . . . . . . . . . . . . . . . . . . . 18
REID. . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Ring & Ball. . . . . . . . . . . . . . . . . . . . . 12
RKA5 . . . . . . . . . . . . . . . . . . . . . . . . 12
RM 2 . . . . . . . . . . . . . . . . . . . . . . . . . 18
RSSOT. . . . . . . . . . . . . . . . . . . . . . . . . 8
RVP. . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Grease Worker. . . . . . . . . . . . . . . . . . 11
GUM . . . . . . . . . . . . . . . . . . . . . . . . . 14

Salinometer . . . . . . . . . . . . . . . . . . . . 16
Salts in Crude Oil. . . . . . . . . . . . . . . . 16
Sample Changer . . . . . . . . . . . . . . . . . 4
SCO1 . . . . . . . . . . . . . . . . . . . . . . . . 16
Sediment in Crude & Fuel Oil. . . . . . . 16
Separation. . . . . . . . . . . . . . . . . . . . . 18
Shear Stability . . . . . . . . . . . . . . . . . . 11
Sieve System. . . . . . . . . . . . . . . . . . . 18
Softening Point. . . . . . . . . . . . . . . . . . 12
Specific Gravity. . . . . . . . . . . . . . . . . . 14
Surface-Detection. . . . . . . . . . . . . . . . 11

B
BPA5. . . . . . . . . . . . . . . . . . . . . . . . . 12
Breaking Point . . . . . . . . . . . . . . . . . . 12

C
CAPPI. . . . . . . . . . . . . . . . . . . . . . . . 10
CAPPIV. . . . . . . . . . . . . . . . . . . . . . . 10
CAPPV . . . . . . . . . . . . . . . . . . . . . . . 10
Carbon Residue. . . . . . . . . . . . . . 15, 16
CCRT. . . . . . . . . . . . . . . . . . . . . . . . . 16
CFPPI. . . . . . . . . . . . . . . . . . . . . . . . 10
CL5 . . . . . . . . . . . . . . . . . . . . . . . . . . 6
CLA5 . . . . . . . . . . . . . . . . . . . . . . . . . 4
Cleveland. . . . . . . . . . . . . . . . . . . . . 4, 6
Cloud & Pour Point. . . . . . . . . . . . . . . 10
Cold Filter Plugging Point. . . . . . . . . . 10
Conical Sieve System. . . . . . . . . . . . . 18
Conradson. . . . . . . . . . . . . . . . . . . . . 16
Copper Strip Tester . . . . . . . . . . . . . . 15
Corrosion. . . . . . . . . . . . . . . . . . . 15, 17

D
DD3. . . . . . . . . . . . . . . . . . . . . . . . . . 13
DDA3 . . . . . . . . . . . . . . . . . . . . . . . . 13
Demulsibility. . . . . . . . . . . . . . . . . . . . 17
Density. . . . . . . . . . . . . . . . . . . . . . . . 14
DH5 . . . . . . . . . . . . . . . . . . . . . . . . . 17
Distillation at Atmospheric Pressure. . . 7
DU4 Eco. . . . . . . . . . . . . . . . . . . . . . . 7
DU4 Pro . . . . . . . . . . . . . . . . . . . . . . . 7
Ductilitymeter. . . . . . . . . . . . . . . . . . . 13

E
Extraction System . . . . . . . . . . . . . . . 16

H
Herschel. . . . . . . . . . . . . . . . . . . . . . . 17

J
Jet Evaporation . . . . . . . . . . . . . . . . . 14

Kinematic Viscosity. . . . . . . . . . . . . . . 14

O
OBA1 . . . . . . . . . . . . . . . . . . . . . . . . . 8
OBA2 . . . . . . . . . . . . . . . . . . . . . . . . . 9
OFA2. . . . . . . . . . . . . . . . . . . . . . . . . . 9
Oil Separation. . . . . . . . . . . . . . . . . . . 18
Oxidation Characteristics. . . . . . . . . . . 9
Oxidation Stability. . . . . . . . . . . . . . . 8, 9

P
Penetration. . . . . . . . . . . . . . . . . . . . . 11
Penetrometer. . . . . . . . . . . . . . . . . . . 11
Pensky-Martens. . . . . . . . . . . . . . . . 4, 5
PetroOxy . . . . . . . . . . . . . . . . . . . . . . . 8
PetroOxy Steel. . . . . . . . . . . . . . . . . . . 8
PM4 . . . . . . . . . . . . . . . . . . . . . . . . . . 5
PMA4SC . . . . . . . . . . . . . . . . . . . . . . 4
PMA5 . . . . . . . . . . . . . . . . . . . . . . . . . 4
PNR 12 . . . . . . . . . . . . . . . . . . . . . . . 11
Pressure Filtration System . . . . . . . . . 18

TAG4. . . . . . . . . . . . . . . . . . . . . . . . . . 5
Tempering Bath . . . . . . . . . . . . . . . . . 14
Tensile Properties. . . . . . . . . . . . . . . . 13
TOO. . . . . . . . . . . . . . . . . . . . . . . . . . . 9
TOR. . . . . . . . . . . . . . . . . . . . . . . . . . 17
TOST. . . . . . . . . . . . . . . . . . . . . . . . . . 9

V
Vapor Pressure. . . . . . . . . . . . . . . . . . . 7
Viscobath. . . . . . . . . . . . . . . . . . . . . . 14

Z
ZPA3. . . . . . . . . . . . . . . . . . . . . . . . . . 6

Glossary - Standards
ASTM

DIN

IP

ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM

DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN
DIN

IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP
IP

D 5 . . . . . . . . . . . . . 11
D 36 . . . . . . . . . . . . 12
D 56 . . . . . . . . . . . . . 5
D 70 . . . . . . . . . 14, 19
D 86 . . . . . . . . . . . . . 7
D 92 . . . . . . . . . . . 4, 6
D 93-A+B . . . . . . . . . 5
D 93-A+B+C. . . . . . . 4
D 97 . . . . . . . . . . . . 10
D 113 . . . . . . . . . . . 13
D 130 . . . . . . . . . . . 15
D 189 . . . . . . . . . . . 16
D 217 . . . . . . . . . . . 11
D 287 . . . . . . . . 14, 19
D 323-A+C+D. . . . . . 7
D 381 . . . . . . . . . . . 14
D 445 . . . . . . . . . . . 14
D 446 . . . . . . . . . . . 14
D 473 . . . . . . . . . . . 16
D 524 . . . . . . . . . . . 15
D 525 . . . . . . . . . . 8, 9
D 665 . . . . . . . . . . . 17
D 850 . . . . . . . . . . . . 7
D 873 . . . . . . . . . . 8, 9
D 892 . . . . . . . . . . . 17
D 937 . . . . . . . . . . . 11
D 942 . . . . . . . . . . . . 9
D 943 . . . . . . . . . . . . 9
D 1078 . . . . . . . . . . . 7
D 1298 . . . . . . . 14, 19
D 1319 . . . . . . . . . . 15
D 1321 . . . . . . . . . . 11
D 1401 . . . . . . . . . . 17
D 1403 . . . . . . . . . . 11
D 1481 . . . . . . . 14, 19
D 2111 . . . . . . . . . . 14
D 2111-A. . . . . . . . . 19
D 2170 . . . . . . . . . . 14
D 2274 . . . . . . . . . . . 9
D 2500 . . . . . . . . . . 10
D 3142 . . . . . . . 14, 19
D 3230 . . . . . . . . . . 16
D 3603 . . . . . . . . . . 17
D 3934 . . . . . . . . . . . 5
D 3941 . . . . . . . . . . . 5
D 4310 . . . . . . . . . . . 9
D 5534 . . . . . . . . . . 17
D 5853 . . . . . . . . . . 10
D 6082 . . . . . . . . . . 17
D 6084 . . . . . . . . . . 13
D 6184 . . . . . . . . . . 18
D 6371 . . . . . . . . . . 10
D 7342 . . . . . . . . . . 11
D 7462 . . . . . . . . . . . 9
D 7525 . . . . . . . . . . . 8
D 7545 . . . . . . . . . . . 8
E 28. . . . . . . . . . . . . 12

1996-15 . . . . . . . . . . . 12
51 551-1. . . . . . . . . . . 16
51 579. . . . . . . . . . . . . 11
51 587. . . . . . . . . . . . . . 9
51 755-1. . . . . . . . . . . . 5
51 757. . . . . . . . . . . . . 14
51 757-1. . . . . . . . . . . 19
51 757-3. . . . . . . . . . . 19
51 784. . . . . . . . . . . . . 14
51 794. . . . . . . . . . . . . . 6
51 808. . . . . . . . . . . . . . 9
51 817. . . . . . . . . . . . . 18
52 004. . . . . . . . . . 14, 19
52 013. . . . . . . . . . . . . 13

EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN

116. . . . . . . . . . . . . . . . 10
924. . . . . . . . . . . . . . . . . 5
1238. . . . . . . . . . . . . . . 12
1426. . . . . . . . . . . . . . . 11
1427. . . . . . . . . . . . . . . 12
1871-F. . . . . . . . . . . . . 12
12 593. . . . . . . . . . . . . 12
12 595. . . . . . . . . . . . . 14
13 179-1 . . . . . . . . . . . 12
13 398. . . . . . . . . . . . . 13
13 589. . . . . . . . . . . . . 13
13 703. . . . . . . . . . . . . 13
13 880-3 . . . . . . . . . . . 11
14 522. . . . . . . . . . . . . . 6
16 091. . . . . . . . . . . . . . 8
22 592. . . . . . . . . . . . . . 4
23 015. . . . . . . . . . . . . 10
60 079. . . . . . . . . . . . . . 6

FTM
FTM
FTM
FTM
FTM
FTM
FTM
FTM
FTM
FTM
FTM
FTM
FTM
FTM
FTM
FTM
FTM
FTM
FTM
FTM
FTM

141-4293. . . . . . . . . . . 5
791-201. . . . . . . . . . . 10
791-305. . . . . . . . . . . 14
791-313. . . . . . . . . . . 11
791-321. . . . . . . . . . . 18
791-1101. . . . . . . . . . . 5
791-1102. . . . . . . . . . . 5
791-1103. . . . . . . . . 4, 6
791-3002. . . . . . . . . . 16
791-3302. . . . . . . . . . 14
791-3352. . . . . . . . . 8, 9
791-3354. . . . . . . . . 8, 9
791-3453. . . . . . . . . . . 9
791-3703. . . . . . . . . . 15
791-4011. . . . . . . . . . 17
791-5001. . . . . . . . . . 16
791-5002. . . . . . . . . . 15
791-5308. . . . . . . . . . . 9
791-5315. . . . . . . . . . 17
791-5325. . . . . . . . . . 15

13 . . . . . . . . . . . . . . . . . 16
14 . . . . . . . . . . . . . . . . . 15
15 . . . . . . . . . . . . . . . . . 10
34-A+B . . . . . . . . . . . . . . 5
34-A+B+C . . . . . . . . . . . 4
36 . . . . . . . . . . . . . . . . 4, 6
40 . . . . . . . . . . . . . . . . 8, 9
50 . . . . . . . . . . . . . . . . . 11
53 . . . . . . . . . . . . . . . . . 16
58 . . . . . . . . . . . . . . . . . 12
69-A+C+D. . . . . . . . . . . . 7
71-1+2. . . . . . . . . . . . . . 14
80 . . . . . . . . . . . . . . . . . 12
121 . . . . . . . . . . . . . . . . 18
123 . . . . . . . . . . . . . . . . . 7
131 . . . . . . . . . . . . . . . . 14
135 . . . . . . . . . . . . . . . . 17
138 . . . . . . . . . . . . . . . 8, 9
142 . . . . . . . . . . . . . . . . . 9
146 . . . . . . . . . . . . . . . . 17
154 . . . . . . . . . . . . . . . . 15
156 . . . . . . . . . . . . . . . . 15
157 . . . . . . . . . . . . . . . . . 9
160 . . . . . . . . . . . . . 14, 19
170 . . . . . . . . . . . . . . . 5, 6
189 . . . . . . . . . . . . . 14, 19
190 . . . . . . . . . . . . . 14, 19
195 . . . . . . . . . . . . . . . . . 7
219 . . . . . . . . . . . . . . . . 10
265 . . . . . . . . . . . . . . . . 16
304 . . . . . . . . . . . . . . . . . 5
309 . . . . . . . . . . . . . . . . 10
319 . . . . . . . . . . . . . . . . 14
388 . . . . . . . . . . . . . . . . . 9
441 . . . . . . . . . . . . . . . . 10
491 . . . . . . . . . . . . . . . . . 5
492 . . . . . . . . . . . . . . . . . 5
515 . . . . . . . . . . . . . . . . 13
516 . . . . . . . . . . . . . . . . 13
520 . . . . . . . . . . . . . . . . 13
540 . . . . . . . . . . . . . . . . 14

ISO

ISO
ISO
ISO
ISO
ISO
ISO
ISO
ISO
ISO
ISO
ISO
ISO
ISO
ISO
ISO
ISO
ISO

3735. . . . . . . . . . . . . . 16
3837. . . . . . . . . . . . . . 15
3838. . . . . . . . . . . 14, 19
4262. . . . . . . . . . . . . . 15
4263-1 . . . . . . . . . . . . . 9
4263-2 . . . . . . . . . . . . . 9
4263-3 . . . . . . . . . . . . . 9
4625-1 . . . . . . . . . . . . 12
6246. . . . . . . . . . . . . . 14
6247. . . . . . . . . . . . . . 17
6614. . . . . . . . . . . . . . 17
6615. . . . . . . . . . . . . . 16
7120. . . . . . . . . . . . . . 17
7536. . . . . . . . . . . . . 8, 9
12 205. . . . . . . . . . . . . . 9
13 736. . . . . . . . . . . . 5, 6
15 267. . . . . . . . . . . . . . 5

JIS
JIS
JIS
JIS
JIS
JIS
JIS
JIS
JIS
JIS
JIS
JIS
JIS
JIS
JIS
JIS
JIS
JIS
JIS
JIS
JIS
JIS
JIS

C2101 . . . . . . . . . . . . . . 9
K2207 . . . . . . . 12, 13, 14
K2220 . . . . . . . . 9, 11, 15
K2249 . . . . . . . . . . 14, 19
K2254 . . . . . . . . . . . . . . 7
K2258 . . . . . . . . . . . . . . 7
K2261 . . . . . . . . . . . . . 14
K2265-1. . . . . . . . . . . . . 5
K2265-3. . . . . . . . . . . 4, 5
K2265-4. . . . . . . . . . . 4, 6
K2269 . . . . . . . . . . . . . 10
K2270 . . . . . . . . . . . . . 16
K2276 . . . . . . . . . . . . 8, 9
K2283 . . . . . . . . . . . . . 14
K2287 . . . . . . . . . . . . 8, 9
K2288 . . . . . . . . . . . . . 10
K2510 . . . . . . . . . . . . . 17
K2513 . . . . . . . . . . . . . 15
K2514 . . . . . . . . . . . . . . 9
K2518 . . . . . . . . . . . . . 17
K2536 . . . . . . . . . . . . . 15
K2601 . . . . . . . . . . 10, 16

Other Standards
79/831/EWG . . . . . . . . . . . . 6

ISO
ISO
ISO
ISO
ISO
ISO
ISO
ISO
ISO
ISO
ISO
ISO
ISO
ISO

1516. . . . . . . . . . . . . . . 5
1523. . . . . . . . . . . . . . . 5
2137. . . . . . . . . . . . . . 11
2160. . . . . . . . . . . . . . 15
2592. . . . . . . . . . . . . 4, 6
2719-A+B. . . . . . . . . . . 5
2719-A+B+C. . . . . . . . . 4
3007-A+C+D. . . . . . . . . 7
3015. . . . . . . . . . . . . . 10
3016. . . . . . . . . . . . . . 10
3104. . . . . . . . . . . . . . 14
3105. . . . . . . . . . . . . . 14
3405. . . . . . . . . . . . . . . 7
3675. . . . . . . . . . . 14, 19

AASHTO T48. . . . . . . . . . 4, 6
AASHTO T51. . . . . . . . . . . 13
AASHTO T53. . . . . . . . . . . 12
AASHTO T73. . . . . . . . . . . . 5
AASHTO T172. . . . . . . . . . . 5
AASHTO T300. . . . . . . . . . 13
CEI 79-4. . . . . . . . . . . . . . . . 6
European
Pharmacopoea 2.9.9.. . . . . 11
IEC 60079 . . . . . . . . . . . . . . 6
NACE TM0172-2001. . . . . 17
VDE 0170. . . . . . . . . . . . . . . 6
VV-L-791e-5314. . . . . . . . . . 9

Glossary - References
10 - 11
10-0350
10-0351
10-0354
10-0355
10-0360
10-0361
10-0364
10-0365
10-0460
10-0461
10-0800
10-0801

/
/
/
/
/
/
/
/
/
/
/
/

106176
108310
106177
108311
106178
106179
106180
108312
106196
106197
106209
106210

(230
(115
(230
(115
(230
(115
(230
(115
(230
(115
(230
(115

V, 100 cm). . . . . . . . . . . . . . . . . . . . . . .
V, 100 cm). . . . . . . . . . . . . . . . . . . . . . .
V, 150 cm). . . . . . . . . . . . . . . . . . . . . . .
V, 150 cm). . . . . . . . . . . . . . . . . . . . . . .
V, 100 cm). . . . . . . . . . . . . . . . . . . . . . .
V, 100 cm). . . . . . . . . . . . . . . . . . . . . . .
V, 150 cm). . . . . . . . . . . . . . . . . . . . . . .
V, 150 cm). . . . . . . . . . . . . . . . . . . . . . .
V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13
13
13
13
13
13
13
13
12
12
12
12

11-0904
11-0905
11-0906
11-0907
11-0910
11-0911
11-0912
11-0913
11-5580
11-5582

/
/
/
/
/
/
/
/
/
/

106509
108315
106510
106511
106512
106513
106514
108316
106515
106516

(230 V, Eco+). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
(115 V, Eco+). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
(230 V, EcoThermo+). . . . . . . . . . . . . . . . . . . . . . . 7
(115 V, EcoThermo+). . . . . . . . . . . . . . . . . . . . . . . 7
(230 V, Pro) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
(115 V, Pro) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
(230 V, ProThermo) . . . . . . . . . . . . . . . . . . . . . . . . 7
(115 V, ProThermo) . . . . . . . . . . . . . . . . . . . . . . . . 7
(230 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
(230V, dry point) . . . . . . . . . . . . . . . . . . . . . . . . 7

12-0501
12-0502
12-0503
12-0504
12-0540
12-0541
12-0542
12-0543
12-1650
12-1651
12-1800
12-1801
12-1822
12-1823
12-2270
12-2730
12-2731
12-2772
12-2773
12-5700
12-5701
12-5770
12-5771

/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/

107097
108319
107098
108320
107099
107100
107101
108321
107149
107150
130641
130642
107115
110237
107151
107152
107153
107121
108322
107122
107123
107125
107126

(115/230 V, EU). . . . . . . . . . . . . . . . . . . . . . . .
(115/230 V, US). . . . . . . . . . . . . . . . . . . . . . . .
(115/230 V, EU). . . . . . . . . . . . . . . . . . . . . . . .
(115/230 V, US). . . . . . . . . . . . . . . . . . . . . . . .
(115/230 V, EU). . . . . . . . . . . . . . . . . . . . . . . .
(115/230 V, US). . . . . . . . . . . . . . . . . . . . . . . .
(115/230 V, EU). . . . . . . . . . . . . . . . . . . . . . . .
(115/230 V, US). . . . . . . . . . . . . . . . . . . . . . . .
(230 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(115 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(230 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(115 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(230 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(115 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(230 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(230 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(115 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(115/230 V, EU). . . . . . . . . . . . . . . . . . . . . . . .
(115/230 V, US). . . . . . . . . . . . . . . . . . . . . . . .
(115/230 V, EU). . . . . . . . . . . . . . . . . . . . . . . .
(115/230 V, US). . . . . . . . . . . . . . . . . . . . . . . .
(115/230 V, EU). . . . . . . . . . . . . . . . . . . . . . . .
(115/230 V, US). . . . . . . . . . . . . . . . . . . . . . . .

13-0035
13-0201
13-0202
13-0215
13-0321
13-0496
13-0497
13-0699
13-0700

/
/
/
/
/
/
/
/
/

106537 (230 V, air & steam) . . . . . . . . . . . . . . . . . . . . 14


107034 (vessel <180 bar). . . . . . . . . . . . . . . . . . . . . . . 7
107035 (vessel >180 bar). . . . . . . . . . . . . . . . . . . . . . . 7
106542 (230 V, 3-place bath). . . . . . . . . . . . . . . . . . . . . . 7
106715. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
107128 (115 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
107129 (230 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
106544 (115 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
107156 (230 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

12 - 13
5
5
5
5
5
5
5
5
5
5
6
6
6
6
6
6
6
4
4
4
4
4
4

13-0841
13-0842
13-0843
13-0870
13-0871
13-0929
13-0930
13-1660
13-1661
13-1662
13-1663
13-1664
13-1665
13-1666
13-1667
13-1672
13-2030
13-2250
13-2418
13-3002
13-3003
13-3006
13-3007
13-3008
13-3009
13-3016
13-3017

/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/

106547
106548
106549
107327
107328
107157
107158
107052
107053
107054
107055
108333
108334
107056
108335
106555
106556
107021
107162
107131
107132
107133
107134
107135
107136
108338
108339

(municipal gas). . . . . . . . . . . . . . . . . . . . . . . 16
(butane/propane). . . . . . . . . . . . . . . . . . . . . . 16
(natural gas). . . . . . . . . . . . . . . . . . . . . . . . . . 16
(230 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
(115 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
(115 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
(230 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
(230 V, liquid). . . . . . . . . . . . . . . . . . . . . . . . . . 8
(115 V, liquid). . . . . . . . . . . . . . . . . . . . . . . . . . 8
(230 V, dry heat) . . . . . . . . . . . . . . . . . . . . . . . 8
(115 V, dry heat) . . . . . . . . . . . . . . . . . . . . . . . 8
(230 V, liquid). . . . . . . . . . . . . . . . . . . . . . . . . . 9
(115 V, liquid). . . . . . . . . . . . . . . . . . . . . . . . . . 9
(230 V, dry heat) . . . . . . . . . . . . . . . . . . . . . . . 9
(115 V, dry heat) . . . . . . . . . . . . . . . . . . . . . . . 9
(230 V, dry heat bath) . . . . . . . . . . . . . . . . . . . . . 9
(230 V, air). . . . . . . . . . . . . . . . . . . . . . . . . . . 14
(manometer). . . . . . . . . . . . . . . . . . . . . . . . . . . 7
(230 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
(115/230 V, EU). . . . . . . . . . . . . . . . . . . . . . . . 8
(115/230 V, US). . . . . . . . . . . . . . . . . . . . . . . . 8
(115/230 V, EU, Peltier). . . . . . . . . . . . . . . . . . 8
(115/230 V, US, Peltier). . . . . . . . . . . . . . . . . . 8
(115/230 V, EU). . . . . . . . . . . . . . . . . . . . . . . . 8
(115/230 V, US). . . . . . . . . . . . . . . . . . . . . . . . 8
(115/230 V, EU, Peltier). . . . . . . . . . . . . . . . . . 8
(115/230 V, US, Peltier). . . . . . . . . . . . . . . . . . 8

15 - 26
15-0035 / 107165 (230 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
16-0583
16-0584
16-0724
16-0725
16-1470
16-1471
16-1472
16-1473
16-2360
16-2372
16-2378
16-2600
16-2601

/
/
/
/
/
/
/
/
/
/
/
/
/

106563
106564
106566
106567
106571
108356
106572
108357
106532
106533
107029
106755
108373

(230
(115
(230
(115
(230
(115
(230
(115
(230
(230
(230
(230
(115

V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
V, twin bath). . . . . . . . . . . . . . . . . . . . . . 17
V, twin bath). . . . . . . . . . . . . . . . . . . . . . 17
V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
V, 5 bath). . . . . . . . . . . . . . . . . . . . . . . . 10
V, 1 bath). . . . . . . . . . . . . . . . . . . . . . . . 10
V, 4 bath). . . . . . . . . . . . . . . . . . . . . . . . 10
V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

17-0131
17-0140
17-0210
17-0210
17-0212
17-1210
17-1505
17-1506

/
/
/
/
/
/
/
/

106720. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
106721. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
106583 (230 V, 6-place bath). . . . . . . . . . . . . . . . . . . . . . 7
106583 (230 V, liquid bath). . . . . . . . . . . . . . . . . . . . . . 9
107088 (oxidation vessel). . . . . . . . . . . . . . . . . . . . . . . 9
107030 (manometer). . . . . . . . . . . . . . . . . . . . . . . . . . . 9
106762 (115 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
106763 (230 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

18-1120 / 106813 (100-240 V, EU). . . . . . . . . . . . . . . . . . . . . . . 11


18-1121 / 106814 (100-240 V, US). . . . . . . . . . . . . . . . . . . . . . . 11
20-0120 / 110234 (230 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
26-0017 / 106599 (230 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
26-0018 / 106600 (115 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Glossary - Datasheets
10
10-0350.pdf
10-0360.pdf
10-0457.pdf
10-0800.pdf

(DD 3). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(DDA 3). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(BPA 5). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(RKA 5). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13
13
12
12

11
11-0590.pdf
11-0904.pdf
11-0910.pdf
11-5580.pdf

(CRM Distillation). . . . . . . . . . . . . . . . . . . . . . . . . . . 19
(DU 4 Eco) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
(DU 4 Pro). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
(ADU 4+). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

17

(ABA 4). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(TAG 4). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(PM 4). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(ZPA 3). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(AB 5). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(CL 5). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(PMA 4 SC). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(CLA 5). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(PMA 5). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

18

12
12-0501.pdf
12-0540.pdf
12-1650.pdf
12-1822.pdf
12-2270.pdf
12-2730.pdf
12-2772.pdf
12-5700.pdf
12-5770.pdf

16-0724.pdf
16-0963.pdf
16-1080.pdf
16-1470.pdf
16-2360.pdf
16-2372.pdf
16-2378.pdf
16-2600.pdf

5
5
5
6
6
6
4
4
4

13
13-0035.pdf (GUM air & steam) . . . . . . . . . . . . . . . . . . . . . . . . . 14
13-0201_analog.pdf (RVP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
13-0201_digital.pdf (RVP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
13-0321.pdf (Extraction). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
13-0497.pdf (SCO 1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
13-0626.pdf (CRM Fuel). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
13-0700.pdf (Copper Strip Tester). . . . . . . . . . . . . . . . . . . . . . . . 15
13-0841.pdf (CCRT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
13-0870.pdf (RCRT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
13-0930.pdf (FIA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
13-1660.pdf (OBA 1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
13-1664.pdf (OBA 2). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
13-2030.pdf (GUM air) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
13-2418.pdf (CFPP I) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
13-3002.pdf (PetroOxy Block). . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
13-3006.pdf (PetroOxy Peltier) . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
13-3008.pdf (PetroOxy S Block). . . . . . . . . . . . . . . . . . . . . . . . . . 8
13-3016.pdf (PetroOxy S Peltier). . . . . . . . . . . . . . . . . . . . . . . . . . 8

15 - 16
15-0035.pdf (RM 2). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
16-0371.pdf (Thermometer IP) . . . . . . . . . . . . . . . . . . . . . . . . . . 19
16-0545.pdf (TOO). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
16-0586_ASTM943.pdf (TOST). . . . . . . . . . . . . . . . . . . . . . . . . . . 9
16-0586_ASTM2274.pdf (TOST). . . . . . . . . . . . . . . . . . . . . . . . . . 9
16-0586_ASTM4310.pdf (TOST). . . . . . . . . . . . . . . . . . . . . . . . . . 9
16-0586_DIN51587.pdf (TOST). . . . . . . . . . . . . . . . . . . . . . . . . . . 9
16-0586_ISO4263.pdf (TOST). . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
16-0586_ISO12205.pdf (TOST). . . . . . . . . . . . . . . . . . . . . . . . . . . 9

17-0131.pdf
17-0140.pdf
17-0212.pdf
17-1506.pdf

(TOR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(Thermometer ASTM). . . . . . . . . . . . . . . . . . . . . . .
(CRM Oil) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(Foam Tester) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(CAPP V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(CAPP I) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(CAPP IV). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(DH 5). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17
19
19
17
10
10
10
17

(Sieve System) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
(Pressure System). . . . . . . . . . . . . . . . . . . . . . . . . . 18
(OFA 2). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
(Grease Worker) . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

18-0065.pdf (PNR Tempering). . . . . . . . . . . . . . . . . . . . . . . . . . .


18-0066.pdf (PNR Sample Jars etc.). . . . . . . . . . . . . . . . . . . . . .
18-0101.pdf (PNR Cones & Discs) . . . . . . . . . . . . . . . . . . . . . . .
18-0132.pdf (PNR Plunger & Weight) . . . . . . . . . . . . . . . . . . . . .
18-0134.pdf (PNR Grease Worker). . . . . . . . . . . . . . . . . . . . . . .
18-0260.pdf (PNR Rods & Rams). . . . . . . . . . . . . . . . . . . . . . . .
18-1120_Bitumen.pdf (PNR). . . . . . . . . . . . . . . . . . . . . . . . . . . .
18-1120_Grease.pdf (PNR). . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18-1120.pdf (PNR 12). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18-1160.pdf (PNR Needles) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18-2220.pdf (PNR Test Kits). . . . . . . . . . . . . . . . . . . . . . . . . . . .

19
19
19
19
19
19
11
11
11
19
19

20 - 22
20-0120.pdf (Viscobath). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
22-0000.pdf
22-0050.pdf
22-0100.pdf
22-0120.pdf
22-0200.pdf
22-0230.pdf
22-0360.pdf
22-0400.pdf
22-0530.pdf

(Capillary
(Capillary
(Capillary
(Capillary
(Capillary
(Capillary
(Capillary
(Capillary
(Capillary

CFRV) . . . . . . . . . . . . . . . . . . . . . . . . . . .
CFOV). . . . . . . . . . . . . . . . . . . . . . . . . . .
UDV) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UAV) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BS/IP/RF). . . . . . . . . . . . . . . . . . . . . . . .
BS/IP/SL). . . . . . . . . . . . . . . . . . . . . . . . .
CUSMV). . . . . . . . . . . . . . . . . . . . . . . . . .
MOV). . . . . . . . . . . . . . . . . . . . . . . . . . . .
ZCAV) . . . . . . . . . . . . . . . . . . . . . . . . . . .

19
19
19
19
19
19
19
19
19

(CRM Viscosity). . . . . . . . . . . . . . . . . . . . . . . . . . . .
(Tempering Bath). . . . . . . . . . . . . . . . . . . . . . . . . . .
(Hydrometer). . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(CRM Density). . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(Pycnometer). . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(Ref. Rust Preventives) . . . . . . . . . . . . . . . . . . . . . .
(Ref. Fuels & Additives). . . . . . . . . . . . . . . . . . . . . .
(Ref. Solid Film Lubricants). . . . . . . . . . . . . . . . . .
(Ref. Antifreeze & Soluble Oil). . . . . . . . . . . . . . . . .
(Ref. Lubrication & Hydraulic) . . . . . . . . . . . . . . . . .
(Ref. Special Tests). . . . . . . . . . . . . . . . . . . . . . . . .
(CRM Flash Point). . . . . . . . . . . . . . . . . . . . . . . . . .
(CRM Miscellaneous) . . . . . . . . . . . . . . . . . . . . . . .

19
14
19
19
19
19
19
19
19
19
19
19
19

24 - 50
24-0551.pdf
26-0017.pdf
26-0400.pdf
26-0702.pdf
26-0712.pdf
40-1001.pdf
40-1510.pdf
40-2002.pdf
40-3011.pdf
40-4010.pdf
40-5010.pdf
50-9000.pdf
50-9121.pdf

Specifications subject to change without notice.

07/13 xxxIPxxxEN-x

Instruments for:
Density and concentration
measurement
Rheometry
Viscometry
Sample preparation
Microwave synthesis
Colloid science
X-ray structure analysis
Refractometry
Polarimetry

Anton Paar GmbH


Anton-Paar-Str. 20
A-8054 Graz
Austria - Europe
Tel: +43 (0)316 257-0
Fax: +43 (0)316 257-257
E-mail: info@anton-paar.com
Web: www.anton-paar.com

Volatility
Oxidation Stability
Cold Flow Properties
Consistency & Ductility
Various Petroleum Products
High-precision temperature
measurement