Você está na página 1de 96

3.

TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI DEHIWALA
Table: 04

Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage

Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention

Maximum Power
Current

Mention

Open Circuit Voltage


Short Circuit Current
Nominal Operating Cell
Temperature(NOCT)

Mention
Mention
Mention

Bidders
response
Yes
No
Yes

If 'No indicate the bidders offered

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
272
30.0V

Yes

30.5V

Yes

8.21A

Yes
Yes

37.6V
8.67C

Yes

45C+2C

Yes

Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box

0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion

Front Glass

3.2 mm tempered hl bh
transmission glass. Low
iron

Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard

12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent

Quality Management

ISO 9001 : 2008 or


Equivalent

Name of the Bidder


:
Signature of the Bidder :
Date
:
Common Seal

Yes
Yes
Yes
Yes

-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)

Yes

IP 65

Yes
Yes

Anodized aluminum alloy

Yes
Yes
Yes
Yes
Yes
Yes
Yes

10%
6/6 pcs

Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER

No

Description

Particulars

Specified

I
2

Name of the supplier


Supplier Registration
No.

Mention
Mention

EWIS Peripherals (Pvt) Ltd

3
4
S

Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports

Mention
Mention
Mention

Solar Leading
China

6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type

PV10130

TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase

Yes
Suntree17000TL
Yes
Three phase

10
11
12
13
14
15
16

Proposed Separate
Capacity

Mention

No. of Inverter
Required

Mention

Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection

Mention

17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22

Minimum
Input
Voltage/Start

up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power

17KW
4
-25C + 60C

Mention
IP 65
Required
Required
Required

Fan cooling
Yes
Yes
Yes

4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)

Yes
98.2%
250-800VDC

Yes

1000 VDC

DC(Mention)
250 VDC
AC(Mention)

33.3 A

AC 230 V
50 Hz
Mention

230V
Yes

26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night

Mention
Mention
Mention

0.9 (lead) 0.99 (lag)


N/A

29

Mention

23
24
25

17,000 W

N/A

30
31

Reverse Polarity
Protection
Standards should be
provided

32

Supported Standards

33
34

Rated power output


Syncronization w.r.t
Prevailing voltage
level

Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%

Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE

Value
20kW
+/-5%

No

Description

35 Over voltage and under


Voltage tripping conditions

Specified
V

Particulars
6.2.2

Unless
With 6% of

6%

230
a. Clearing time to
abnormal
Voltages
(% of base
Voltage)

I. V<50

II. 50<=V<88

<2.00

N/A

III. 1 10<=V<120

<1.00

N/A

IV. V>120

36 Over and under frequency


Tripping conditions

Hz

4.2.3

N/A

<0.2
6.2.2

Unless
Within 4752

b. Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)

I.

11.
set

>52

47-52

N/A

<{49.5-47} (adjustable s

0.2
Adjustable
to

point
<0.2-3011

N/A

<0.2-300

37

Capability to withstand

4.1.
8.3

220%

6.3

220%

voltage w.r.t. to the

38

interconnection
Grounding scheme

39

Reconnection time

220%

4. 1.2
s

4.2.6

TT system
Adjustable 6.2.2

TT

>180
>180

E up to
300
40

Limitation of dc injection

.3.1

<0.5

current w.r,t. full


N/A

rated output current

41

at the
point
Output voltage waveform

6.6

50Hz,
sinusoidal

Sine wave

No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code

Name of the Bidder


Signature of the
Bidder : Date
:
Common Seal

Specified
6.11
%
%
%
%
%
%

4.3.3

Required

Particulars
Yes

6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11

<4
<2
<1.5
<0.6
<0.3
<5
Required

N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately

3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI KANDY
Table: 04

Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage

Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention

Maximum Power
Current

Mention

Open Circuit Voltage


Short Circuit Current
Nominal Operating Cell
Temperature(NOCT)

Mention
Mention
Mention

Bidders
response
Yes
No
Yes

If 'No indicate the bidders offered

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
100
30.0V

Yes

30.5V

Yes

8.21A

Yes
Yes

37.6V
8.67C

Yes

45C+2C

Yes

Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box

0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion

Front Glass

3.2 mm tempered hl bh
transmission glass. Low
iron

Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard

12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent

Quality Management

ISO 9001 : 2008 or


Equivalent

Name of the Bidder


:
Signature of the Bidder :
Date
:
Common Seal

Yes
Yes
Yes
Yes

-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)

Yes

IP 65

Yes
Yes

Anodized aluminum alloy

Yes
Yes
Yes
Yes
Yes
Yes
Yes

10%
6/6 pcs

Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER

No

Description

Particulars

Specified

I
2

Name of the supplier


Supplier Registration
No.

Mention
Mention

EWIS Peripherals (Pvt) Ltd

3
4
S

Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports

Mention
Mention
Mention

Solar Leading
China

6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type

PV10130

TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase

Yes
Suntree 10000TL,15000TL
Yes
Three phase

10
11
12
13
14
15
16

Proposed Separate
Capacity

Mention

No. of Inverter
Required

Mention

Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection

Mention

17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22

Minimum
Input
Voltage/Start

up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power

10KW,15KW
1,1
-25C + 60C

Mention
IP 65
Required
Required
Required

Fan cooling
Yes
Yes
Yes

4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)

Yes
98.2%
250-800VDC

Yes

1000 VDC

DC(Mention)
250 VDC
AC(Mention)

33.3 A

AC 230 V
50 Hz
Mention

230V
Yes

26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night

Mention
Mention
Mention

0.9 (lead) 0.99 (lag)


N/A

29

Mention

23
24
25

10,000 W,15000W

N/A

30
31

Reverse Polarity
Protection
Standards should be
provided

32

Supported Standards

33
34

Rated power output


Syncronization w.r.t
Prevailing voltage
level

Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%

Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE

Value
20kW
+/-5%

No

Description

35 Over voltage and under


Voltage tripping conditions

Specified
V

Particulars
6.2.2

Unless
With 6% of

6%

230
c. Clearing time to
abnormal
Voltages
(% of base
Voltage)

I. V<50

II. 50<=V<88

<2.00

N/A

III. 1 10<=V<120

<1.00

N/A

IV. V>120

36 Over and under frequency


Tripping conditions

Hz

4.2.3

N/A

<0.2
6.2.2

Unless
Within 4752

d. Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)

II.

11.
set

>52

47-52

N/A

<{49.5-47} (adjustable s

0.2
Adjustable
to

point
<0.2-3011

N/A

<0.2-300

37

Capability to withstand

4.1.
8.3

220%

6.3

220%

voltage w.r.t. to the

38

interconnection
Grounding scheme

39

Reconnection time

220%

4. 1.2
s

4.2.6

TT system
Adjustable 6.2.2

TT

>180
>180

E up to
300
40

Limitation of dc injection

.3.1

<0.5

current w.r,t. full


N/A

rated output current

41

at the
point
Output voltage waveform

6.6

50Hz,
sinusoidal

Sine wave

No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code

Name of the Bidder


Signature of the
Bidder : Date
:
Common Seal

Specified
6.11
%
%
%
%
%
%

4.3.3

Required

Particulars
Yes

6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11

<4
<2
<1.5
<0.6
<0.3
<5
Required

N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately

3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI GALLE
Table: 04

Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage

Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention

Maximum Power
Current

Mention

Open Circuit Voltage


Short Circuit Current
Nominal Operating Cell
Temperature(NOCT)

Mention
Mention
Mention

Bidders
response
Yes
No
Yes

If 'No indicate the bidders offered

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
172
30.0V

Yes

30.5V

Yes

8.21A

Yes
Yes

37.6V
8.67C

Yes

45C+2C

Yes

Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box

0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion

Front Glass

3.2 mm tempered hl bh
transmission glass. Low
iron

Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard

12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent

Quality Management

ISO 9001 : 2008 or


Equivalent

Name of the Bidder


:
Signature of the Bidder :
Date
:
Common Seal

Yes
Yes
Yes
Yes

-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)

Yes

IP 65

Yes
Yes

Anodized aluminum alloy

Yes
Yes
Yes
Yes
Yes
Yes
Yes

10%
6/6 pcs

Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER

No

Description

Particulars

Specified

I
2

Name of the supplier


Supplier Registration
No.

Mention
Mention

EWIS Peripherals (Pvt) Ltd

3
4
S

Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports

Mention
Mention
Mention

Solar Leading
China

6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type

PV10130

TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase

Yes
Suntree 20000TL
Yes
Three phase

10
11
12
13
14
15
16

Proposed Separate
Capacity

Mention

No. of Inverter
Required

Mention

Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection

Mention

17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22

Minimum
Input
Voltage/Start

up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power

20KW
1
-25C + 60C

Mention
IP 65
Required
Required
Required

Fan cooling
Yes
Yes
Yes

4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)

Yes
98.2%
250-800VDC

Yes

1000 VDC

DC(Mention)
250 VDC
AC(Mention)

33.3 A

AC 230 V
50 Hz
Mention

230V
Yes

26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night

Mention
Mention
Mention

0.9 (lead) 0.99 (lag)


N/A

29

Mention

23
24
25

20,000 W

N/A

30
31

Reverse Polarity
Protection
Standards should be
provided

32

Supported Standards

33
34

Rated power output


Syncronization w.r.t
Prevailing voltage
level

Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%

Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE

Value
20kW
+/-5%

No

Description

35 Over voltage and under


Voltage tripping conditions

Specified
V

Particulars
6.2.2

Unless
With 6% of

6%

230
e. Clearing time to
abnormal
Voltages
(% of base
Voltage)

I. V<50

II. 50<=V<88

<2.00

N/A

III. 1 10<=V<120

<1.00

N/A

IV. V>120

36 Over and under frequency


Tripping conditions

Hz

4.2.3

N/A

<0.2
6.2.2

Unless
Within 4752

f.

Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)

III.

11.
set

>52

47-52

N/A

<{49.5-47} (adjustable s

0.2
Adjustable
to

point
<0.2-3011

N/A

<0.2-300

37

Capability to withstand

4.1.
8.3

220%

6.3

220%

voltage w.r.t. to the

38

interconnection
Grounding scheme

39

Reconnection time

220%

4. 1.2
s

4.2.6

TT system
Adjustable 6.2.2

TT

>180
>180

E up to
300
40

Limitation of dc injection

.3.1

<0.5

current w.r,t. full


N/A

rated output current

41

at the
point
Output voltage waveform

6.6

50Hz,
sinusoidal

Sine wave

No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code

Name of the Bidder


Signature of the
Bidder : Date
:
Common Seal

Specified
6.11
%
%
%
%
%
%

4.3.3

Required

Particulars
Yes

6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11

<4
<2
<1.5
<0.6
<0.3
<5
Required

N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately

3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI AMPARA
Table: 04

Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage

Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention

Maximum Power
Current

Mention

Open Circuit Voltage


Short Circuit Current
Nominal Operating Cell
Temperature(NOCT)

Mention
Mention
Mention

Bidders
response
Yes
No
Yes

If 'No indicate the bidders offered

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
240
30.0V

Yes

30.5V

Yes

8.21A

Yes
Yes

37.6V
8.67C

Yes

45C+2C

Yes

Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box

0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion

Front Glass

3.2 mm tempered hl bh
transmission glass. Low
iron

Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard

12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent

Quality Management

ISO 9001 : 2008 or


Equivalent

Name of the Bidder


:
Signature of the Bidder :
Date
:
Common Seal

Yes
Yes
Yes
Yes

-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)

Yes

IP 65

Yes
Yes

Anodized aluminum alloy

Yes
Yes
Yes
Yes
Yes
Yes
Yes

10%
6/6 pcs

Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER

No

Description

Particulars

Specified

I
2

Name of the supplier


Supplier Registration
No.

Mention
Mention

EWIS Peripherals (Pvt) Ltd

3
4
S

Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports

Mention
Mention
Mention

Solar Leading
China

6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type

PV10130

TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase

Yes
Suntree 20000TL
Yes
Three phase

10
11
12
13
14
15
16

Proposed Separate
Capacity

Mention

No. of Inverter
Required

Mention

Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection

Mention

17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22

Minimum
Input
Voltage/Start

up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power

20KW
3
-25C + 60C

Mention
IP 65
Required
Required
Required

Fan cooling
Yes
Yes
Yes

4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)

Yes
98.2%
250-800VDC

Yes

1000 VDC

DC(Mention)
250 VDC
AC(Mention)

33.3 A

AC 230 V
50 Hz
Mention

230V
Yes

26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night

Mention
Mention
Mention

0.9 (lead) 0.99 (lag)


N/A

29

Mention

23
24
25

20,000 W

N/A

30
31

Reverse Polarity
Protection
Standards should be
provided

32

Supported Standards

33
34

Rated power output


Syncronization w.r.t
Prevailing voltage
level

Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%

Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE

Value
20kW
+/-5%

No

Description

35 Over voltage and under


Voltage tripping conditions

Specified
V

Particulars
6.2.2

Unless
With 6% of

6%

230
g. Clearing time to
abnormal
Voltages
(% of base
Voltage)

I. V<50

II. 50<=V<88

<2.00

N/A

III. 1 10<=V<120

<1.00

N/A

IV. V>120

36 Over and under frequency


Tripping conditions

Hz

4.2.3

N/A

<0.2
6.2.2

Unless
Within 4752

h. Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)

IV.

11.
set

>52

47-52

N/A

<{49.5-47} (adjustable s

0.2
Adjustable
to

point
<0.2-3011

N/A

<0.2-300

37

Capability to withstand

4.1.
8.3

220%

6.3

220%

voltage w.r.t. to the

38

interconnection
Grounding scheme

39

Reconnection time

220%

4. 1.2
s

4.2.6

TT system
Adjustable 6.2.2

TT

>180
>180

E up to
300
40

Limitation of dc injection

.3.1

<0.5

current w.r,t. full


N/A

rated output current

41

at the
point
Output voltage waveform

6.6

50Hz,
sinusoidal

Sine wave

No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code

Name of the Bidder


Signature of the
Bidder : Date
:
Common Seal

Specified
6.11
%
%
%
%
%
%

4.3.3

Required

Particulars
Yes

6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11

<4
<2
<1.5
<0.6
<0.3
<5
Required

N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately

3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI JAFFNA
Table: 04

Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage

Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention

Maximum Power
Current

Mention

Open Circuit Voltage


Short Circuit Current
Nominal Operating Cell
Temperature(NOCT)

Mention
Mention
Mention

Bidders
response
Yes
No
Yes

If 'No indicate the bidders offered

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
120
30.0V

Yes

30.5V

Yes

8.21A

Yes
Yes

37.6V
8.67C

Yes

45C+2C

Yes

Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box

0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion

Front Glass

3.2 mm tempered hl bh
transmission glass. Low
iron

Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard

12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent

Quality Management

ISO 9001 : 2008 or


Equivalent

Name of the Bidder


:
Signature of the Bidder :
Date
:
Common Seal

Yes
Yes
Yes
Yes

-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)

Yes

IP 65

Yes
Yes

Anodized aluminum alloy

Yes
Yes
Yes
Yes
Yes
Yes
Yes

10%
6/6 pcs

Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER

No

Description

Particulars

Specified

I
2

Name of the supplier


Supplier Registration
No.

Mention
Mention

EWIS Peripherals (Pvt) Ltd

3
4
S

Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports

Mention
Mention
Mention

Solar Leading
China

6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type

PV10130

TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase

Yes
Suntree 30000TL
Yes
Three phase

10
11
12
13
14
15
16

Proposed Separate
Capacity

Mention

No. of Inverter
Required

Mention

Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection

Mention

17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22

Minimum
Input
Voltage/Start

up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power

30
1
-25C + 60C

Mention
IP 65
Required
Required
Required

Fan cooling
Yes
Yes
Yes

4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)

Yes
98.2%
250-800VDC

Yes

1000 VDC

DC(Mention)
250 VDC
AC(Mention)

33.3 A

AC 230 V
50 Hz
Mention

230V
Yes

26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night

Mention
Mention
Mention

0.9 (lead) 0.99 (lag)


N/A

29

Mention

23
24
25

30,000 W

N/A

30
31

Reverse Polarity
Protection
Standards should be
provided

32

Supported Standards

33
34

Rated power output


Syncronization w.r.t
Prevailing voltage
level

Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%

Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE

Value
20kW
+/-5%

No

Description

35 Over voltage and under


Voltage tripping conditions

Specified
V

Particulars
6.2.2

Unless
With 6% of

6%

230
i.

Clearing time to
abnormal
Voltages
(% of base
Voltage)

I. V<50

II. 50<=V<88

<2.00

N/A

III. 1 10<=V<120

<1.00

N/A

IV. V>120

36 Over and under frequency


Tripping conditions

Hz

4.2.3

N/A

<0.2
6.2.2

Unless
Within 4752

j.

Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)

V.

11.
set

>52

47-52

N/A

<{49.5-47} (adjustable s

0.2
Adjustable
to

point
<0.2-3011

N/A

<0.2-300

37

Capability to withstand

4.1.
8.3

220%

6.3

220%

voltage w.r.t. to the

38

interconnection
Grounding scheme

39

Reconnection time

220%

4. 1.2
s

4.2.6

TT system
Adjustable 6.2.2

TT

>180
>180

E up to
300
40

Limitation of dc injection

.3.1

<0.5

current w.r,t. full


N/A

rated output current

41

at the
point
Output voltage waveform

6.6

50Hz,
sinusoidal

Sine wave

No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code

Name of the Bidder


Signature of the
Bidder : Date
:
Common Seal

Specified
6.11
%
%
%
%
%
%

4.3.3

Required

Particulars
Yes

6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11

<4
<2
<1.5
<0.6
<0.3
<5
Required

N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately

3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI BATTICALOA
Table: 04

Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage

Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention

Maximum Power
Current

Mention

Open Circuit Voltage


Short Circuit Current
Nominal Operating Cell
Temperature(NOCT)

Mention
Mention
Mention

Bidders
response
Yes
No
Yes

If 'No indicate the bidders offered

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
20
30.0V

Yes

30.5V

Yes

8.21A

Yes
Yes

37.6V
8.67C

Yes

45C+2C

Yes

Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box

0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion

Front Glass

3.2 mm tempered hl bh
transmission glass. Low
iron

Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard

12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent

Quality Management

ISO 9001 : 2008 or


Equivalent

Name of the Bidder


:
Signature of the Bidder :
Date
:
Common Seal

Yes
Yes
Yes
Yes

-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)

Yes

IP 65

Yes
Yes

Anodized aluminum alloy

Yes
Yes
Yes
Yes
Yes
Yes
Yes

10%
6/6 pcs

Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER

No

Description

Particulars

Specified

I
2

Name of the supplier


Supplier Registration
No.

Mention
Mention

EWIS Peripherals (Pvt) Ltd

3
4
S

Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports

Mention
Mention
Mention

Solar Leading
China

6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type

PV10130

TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase

Yes
Suntree 5000TL
Yes
Single phase

10
11
12
13
14
15
16

Proposed Separate
Capacity

Mention

No. of Inverter
Required

Mention

Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection

Mention

17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22

Minimum
Input
Voltage/Start

up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power

5KW
1
-25C + 60C

Mention
IP 65
Required
Required
Required

Fan cooling
Yes
Yes
Yes

4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)

Yes
98.2%
250-800VDC

Yes

1000 VDC

DC(Mention)
250 VDC
AC(Mention)

33.3 A

AC 230 V
50 Hz
Mention

230V
Yes

26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night

Mention
Mention
Mention

0.9 (lead) 0.99 (lag)


N/A

29

Mention

23
24
25

5,000 W

N/A

30
31

Reverse Polarity
Protection
Standards should be
provided

32

Supported Standards

33
34

Rated power output


Syncronization w.r.t
Prevailing voltage
level

Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%

Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE

Value
20kW
+/-5%

No

Description

35 Over voltage and under


Voltage tripping conditions

Specified
V

Particulars
6.2.2

Unless
With 6% of

6%

230
k. Clearing time to
abnormal
Voltages
(% of base
Voltage)

I. V<50

II. 50<=V<88

<2.00

N/A

III. 1 10<=V<120

<1.00

N/A

IV. V>120

36 Over and under frequency


Tripping conditions

Hz

4.2.3

N/A

<0.2
6.2.2

Unless
Within 4752

l.

Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)

VI.

11.
set

>52

47-52

N/A

<{49.5-47} (adjustable s

0.2
Adjustable
to

point
<0.2-3011

N/A

<0.2-300

37

Capability to withstand

4.1.
8.3

220%

6.3

220%

voltage w.r.t. to the

38

interconnection
Grounding scheme

39

Reconnection time

220%

4. 1.2
s

4.2.6

TT system
Adjustable 6.2.2

TT

>180
>180

E up to
300
40

Limitation of dc injection

.3.1

<0.5

current w.r,t. full


N/A

rated output current

41

at the
point
Output voltage waveform

6.6

50Hz,
sinusoidal

Sine wave

No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code

Name of the Bidder


Signature of the
Bidder : Date
:
Common Seal

Specified
6.11
%
%
%
%
%
%

4.3.3

Required

Particulars
Yes

6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11

<4
<2
<1.5
<0.6
<0.3
<5
Required

N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately

3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI KURUNEGALA
Table: 04

Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage

Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention

Maximum Power
Current

Mention

Open Circuit Voltage


Short Circuit Current
Nominal Operating Cell
Temperature(NOCT)

Mention
Mention
Mention

Bidders
response
Yes
No
Yes

If 'No indicate the bidders offered

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
160
30.0V

Yes

30.5V

Yes

8.21A

Yes
Yes

37.6V
8.67C

Yes

45C+2C

Yes

Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box

0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion

Front Glass

3.2 mm tempered hl bh
transmission glass. Low
iron

Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard

12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent

Quality Management

ISO 9001 : 2008 or


Equivalent

Name of the Bidder


:
Signature of the Bidder :
Date
:
Common Seal

Yes
Yes
Yes
Yes

-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)

Yes

IP 65

Yes
Yes

Anodized aluminum alloy

Yes
Yes
Yes
Yes
Yes
Yes
Yes

10%
6/6 pcs

Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER

No

Description

Particulars

Specified

I
2

Name of the supplier


Supplier Registration
No.

Mention
Mention

EWIS Peripherals (Pvt) Ltd

3
4
S

Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports

Mention
Mention
Mention

Solar Leading
China

6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type

PV10130

TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase

Yes
Suntree 20000TL
Yes
Three phase

10
11
12
13
14
15
16

Proposed Separate
Capacity

Mention

No. of Inverter
Required

Mention

Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection

Mention

17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22

Minimum
Input
Voltage/Start

up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power

20KW
2
-25C + 60C

Mention
IP 65
Required
Required
Required

Fan cooling
Yes
Yes
Yes

4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)

Yes
98.2%
250-800VDC

Yes

1000 VDC

DC(Mention)
250 VDC
AC(Mention)

33.3 A

AC 230 V
50 Hz
Mention

230V
Yes

26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night

Mention
Mention
Mention

0.9 (lead) 0.99 (lag)


N/A

29

Mention

23
24
25

20,000 W

N/A

30
31

Reverse Polarity
Protection
Standards should be
provided

32

Supported Standards

33
34

Rated power output


Syncronization w.r.t
Prevailing voltage
level

Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%

Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE

Value
20kW
+/-5%

No

Description

35 Over voltage and under


Voltage tripping conditions

Specified
V

Particulars
6.2.2

Unless
With 6% of

6%

230
m. Clearing time to
abnormal
Voltages
(% of base
Voltage)

I. V<50

II. 50<=V<88

<2.00

N/A

III. 1 10<=V<120

<1.00

N/A

IV. V>120

36 Over and under frequency


Tripping conditions

Hz

4.2.3

N/A

<0.2
6.2.2

Unless
Within 4752

n. Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)

VII.

11.
set

>52

47-52

N/A

<{49.5-47} (adjustable s

0.2
Adjustable
to

point
<0.2-3011

N/A

<0.2-300

37

Capability to withstand

4.1.
8.3

220%

6.3

220%

voltage w.r.t. to the

38

interconnection
Grounding scheme

39

Reconnection time

220%

4. 1.2
s

4.2.6

TT system
Adjustable 6.2.2

TT

>180
>180

E up to
300
40

Limitation of dc injection

.3.1

<0.5

current w.r,t. full


N/A

rated output current

41

at the
point
Output voltage waveform

6.6

50Hz,
sinusoidal

Sine wave

No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code

Name of the Bidder


Signature of the
Bidder : Date
:
Common Seal

Specified
6.11
%
%
%
%
%
%

4.3.3

Required

Particulars
Yes

6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11

<4
<2
<1.5
<0.6
<0.3
<5
Required

N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately

3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI KEGALLE
Table: 04

Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage

Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention

Maximum Power
Current

Mention

Open Circuit Voltage


Short Circuit Current
Nominal Operating Cell
Temperature(NOCT)

Mention
Mention
Mention

Bidders
response
Yes
No
Yes

If 'No indicate the bidders offered

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
32
30.0V

Yes

30.5V

Yes

8.21A

Yes
Yes

37.6V
8.67C

Yes

45C+2C

Yes

Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box

0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion

Front Glass

3.2 mm tempered hl bh
transmission glass. Low
iron

Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard

12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent

Quality Management

ISO 9001 : 2008 or


Equivalent

Name of the Bidder


:
Signature of the Bidder :
Date
:
Common Seal

Yes
Yes
Yes
Yes

-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)

Yes

IP 65

Yes
Yes

Anodized aluminum alloy

Yes
Yes
Yes
Yes
Yes
Yes
Yes

10%
6/6 pcs

Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER

No

Description

Particulars

Specified

I
2

Name of the supplier


Supplier Registration
No.

Mention
Mention

EWIS Peripherals (Pvt) Ltd

3
4
S

Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports

Mention
Mention
Mention

Solar Leading
China

6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type

PV10130

TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase

Yes
Suntree 8000TL
Yes
Three phase

10
11
12
13
14
15
16

Proposed Separate
Capacity

Mention

No. of Inverter
Required

Mention

Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection

Mention

17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22

Minimum
Input
Voltage/Start

up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power

8
1
-25C + 60C

Mention
IP 65
Required
Required
Required

Fan cooling
Yes
Yes
Yes

4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)

Yes
98.2%
250-800VDC

Yes

1000 VDC

DC(Mention)
250 VDC
AC(Mention)

33.3 A

AC 230 V
50 Hz
Mention

230V
Yes

26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night

Mention
Mention
Mention

0.9 (lead) 0.99 (lag)


N/A

29

Mention

23
24
25

8,000 W

N/A

30
31

Reverse Polarity
Protection
Standards should be
provided

32

Supported Standards

33
34

Rated power output


Syncronization w.r.t
Prevailing voltage
level

Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%

Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE

Value
20kW
+/-5%

No

Description

35 Over voltage and under


Voltage tripping conditions

Specified
V

Particulars
6.2.2

Unless
With 6% of

6%

230
o. Clearing time to
abnormal
Voltages
(% of base
Voltage)

I. V<50

II. 50<=V<88

<2.00

N/A

III. 1 10<=V<120

<1.00

N/A

IV. V>120

36 Over and under frequency


Tripping conditions

Hz

4.2.3

N/A

<0.2
6.2.2

Unless
Within 4752

p. Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)

VIII.

11.
set

>52

47-52

N/A

<{49.5-47} (adjustable s

0.2
Adjustable
to

point
<0.2-3011

N/A

<0.2-300

37

Capability to withstand

4.1.
8.3

220%

6.3

220%

voltage w.r.t. to the

38

interconnection
Grounding scheme

39

Reconnection time

220%

4. 1.2
s

4.2.6

TT system
Adjustable 6.2.2

TT

>180
>180

E up to
300
40

Limitation of dc injection

.3.1

<0.5

current w.r,t. full


N/A

rated output current

41

at the
point
Output voltage waveform

6.6

50Hz,
sinusoidal

Sine wave

No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code

Name of the Bidder


Signature of the
Bidder : Date
:
Common Seal

Specified
6.11
%
%
%
%
%
%

4.3.3

Required

Particulars
Yes

6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11

<4
<2
<1.5
<0.6
<0.3
<5
Required

N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately

3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI TRINCOMALEE
Table: 04

Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage

Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention

Maximum Power
Current

Mention

Open Circuit Voltage


Short Circuit Current
Nominal Operating Cell
Temperature(NOCT)

Mention
Mention
Mention

Bidders
response
Yes
No
Yes

If 'No indicate the bidders offered

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
160
30.0V

Yes

30.5V

Yes

8.21A

Yes
Yes

37.6V
8.67C

Yes

45C+2C

Yes

Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box

0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion

Front Glass

3.2 mm tempered hl bh
transmission glass. Low
iron

Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard

12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent

Quality Management

ISO 9001 : 2008 or


Equivalent

Name of the Bidder


:
Signature of the Bidder :
Date
:
Common Seal

Yes
Yes
Yes
Yes

-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)

Yes

IP 65

Yes
Yes

Anodized aluminum alloy

Yes
Yes
Yes
Yes
Yes
Yes
Yes

10%
6/6 pcs

Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER

No

Description

Particulars

Specified

I
2

Name of the supplier


Supplier Registration
No.

Mention
Mention

EWIS Peripherals (Pvt) Ltd

3
4
S

Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports

Mention
Mention
Mention

Solar Leading
China

6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type

PV10130

TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase

Yes
Suntree 20000TL
Yes
Three phase

10
11
12
13
14
15
16

Proposed Separate
Capacity

Mention

No. of Inverter
Required

Mention

Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection

Mention

17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22

Minimum
Input
Voltage/Start

up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power

20KW
2
-25C + 60C

Mention
IP 65
Required
Required
Required

Fan cooling
Yes
Yes
Yes

4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)

Yes
98.2%
250-800VDC

Yes

1000 VDC

DC(Mention)
250 VDC
AC(Mention)

33.3 A

AC 230 V
50 Hz
Mention

230V
Yes

26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night

Mention
Mention
Mention

0.9 (lead) 0.99 (lag)


N/A

29

Mention

23
24
25

20,000 W

N/A

30
31

Reverse Polarity
Protection
Standards should be
provided

32

Supported Standards

33
34

Rated power output


Syncronization w.r.t
Prevailing voltage
level

Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%

Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE

Value
20kW
+/-5%

No

Description

35 Over voltage and under


Voltage tripping conditions

Specified
V

Particulars
6.2.2

Unless
With 6% of

6%

230
q. Clearing time to
abnormal
Voltages
(% of base
Voltage)

I. V<50

II. 50<=V<88

<2.00

N/A

III. 1 10<=V<120

<1.00

N/A

IV. V>120

36 Over and under frequency


Tripping conditions

Hz

4.2.3

N/A

<0.2
6.2.2

Unless
Within 4752

r.

Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)

IX.

11.
set

>52

47-52

N/A

<{49.5-47} (adjustable s

0.2
Adjustable
to

point
<0.2-3011

N/A

<0.2-300

37

Capability to withstand

4.1.
8.3

220%

6.3

220%

voltage w.r.t. to the

38

interconnection
Grounding scheme

39

Reconnection time

220%

4. 1.2
s

4.2.6

TT system
Adjustable 6.2.2

TT

>180
>180

E up to
300
40

Limitation of dc injection

.3.1

<0.5

current w.r,t. full


N/A

rated output current

41

at the
point
Output voltage waveform

6.6

50Hz,
sinusoidal

Sine wave

No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code

Name of the Bidder


Signature of the
Bidder : Date
:
Common Seal

Specified
6.11
%
%
%
%
%
%

4.3.3

Required

Particulars
Yes

6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11

<4
<2
<1.5
<0.6
<0.3
<5
Required

N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately

3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI BADULLA
Table: 04

Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage

Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention

Maximum Power
Current

Mention

Open Circuit Voltage


Short Circuit Current
Nominal Operating Cell
Temperature(NOCT)

Mention
Mention
Mention

Bidders
response
Yes
No
Yes

If 'No indicate the bidders offered

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
60
30.0V

Yes

30.5V

Yes

8.21A

Yes
Yes

37.6V
8.67C

Yes

45C+2C

Yes

Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box

0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion

Front Glass

3.2 mm tempered hl bh
transmission glass. Low
iron

Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard

12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent

Quality Management

ISO 9001 : 2008 or


Equivalent

Name of the Bidder


:
Signature of the Bidder :
Date
:
Common Seal

Yes
Yes
Yes
Yes

-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)

Yes

IP 65

Yes
Yes

Anodized aluminum alloy

Yes
Yes
Yes
Yes
Yes
Yes
Yes

10%
6/6 pcs

Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER

No

Description

Particulars

Specified

I
2

Name of the supplier


Supplier Registration
No.

Mention
Mention

EWIS Peripherals (Pvt) Ltd

3
4
S

Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports

Mention
Mention
Mention

Solar Leading
China

6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type

PV10130

TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase

Yes
Suntree 15000TL
Yes
Three phase

10
11
12
13
14
15
16

Proposed Separate
Capacity

Mention

No. of Inverter
Required

Mention

Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection

Mention

17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22

Minimum
Input
Voltage/Start

up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power

15KW
1
-25C + 60C

Mention
IP 65
Required
Required
Required

Fan cooling
Yes
Yes
Yes

4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)

Yes
98.2%
250-800VDC

Yes

1000 VDC

DC(Mention)
250 VDC
AC(Mention)

33.3 A

AC 230 V
50 Hz
Mention

230V
Yes

26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night

Mention
Mention
Mention

0.9 (lead) 0.99 (lag)


N/A

29

Mention

23
24
25

15,000 W

N/A

30
31

Reverse Polarity
Protection
Standards should be
provided

32

Supported Standards

33
34

Rated power output


Syncronization w.r.t
Prevailing voltage
level

Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%

Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE

Value
20kW
+/-5%

No

Description

35 Over voltage and under


Voltage tripping conditions

Specified
V

Particulars
6.2.2

Unless
With 6% of

6%

230
s. Clearing time to
abnormal
Voltages
(% of base
Voltage)

I. V<50

II. 50<=V<88

<2.00

N/A

III. 1 10<=V<120

<1.00

N/A

IV. V>120

36 Over and under frequency


Tripping conditions

Hz

4.2.3

N/A

<0.2
6.2.2

Unless
Within 4752

t.

Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)

X.

11.
set

>52

47-52

N/A

<{49.5-47} (adjustable s

0.2
Adjustable
to

point
<0.2-3011

N/A

<0.2-300

37

Capability to withstand

4.1.
8.3

220%

6.3

220%

voltage w.r.t. to the

38

interconnection
Grounding scheme

39

Reconnection time

220%

4. 1.2
s

4.2.6

TT system
Adjustable 6.2.2

TT

>180
>180

E up to
300
40

Limitation of dc injection

.3.1

<0.5

current w.r,t. full


N/A

rated output current

41

at the
point
Output voltage waveform

6.6

50Hz,
sinusoidal

Sine wave

No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code

Name of the Bidder


Signature of the
Bidder : Date
:
Common Seal

Specified
6.11
%
%
%
%
%
%

4.3.3

Required

Particulars
Yes

6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11

<4
<2
<1.5
<0.6
<0.3
<5
Required

N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately

3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI TANGALLE
Table: 04

Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage

Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention

Maximum Power
Current

Mention

Open Circuit Voltage


Short Circuit Current
Nominal Operating Cell
Temperature(NOCT)

Mention
Mention
Mention

Bidders
response
Yes
No
Yes

If 'No indicate the bidders offered

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
20
30.0V

Yes

30.5V

Yes

8.21A

Yes
Yes

37.6V
8.67C

Yes

45C+2C

Yes

Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box

0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion

Front Glass

3.2 mm tempered hl bh
transmission glass. Low
iron

Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard

12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent

Quality Management

ISO 9001 : 2008 or


Equivalent

Name of the Bidder


:
Signature of the Bidder :
Date
:
Common Seal

Yes
Yes
Yes
Yes

-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)

Yes

IP 65

Yes
Yes

Anodized aluminum alloy

Yes
Yes
Yes
Yes
Yes
Yes
Yes

10%
6/6 pcs

Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER

No

Description

Particulars

Specified

I
2

Name of the supplier


Supplier Registration
No.

Mention
Mention

EWIS Peripherals (Pvt) Ltd

3
4
S

Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports

Mention
Mention
Mention

Solar Leading
China

6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type

PV10130

TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase

Yes
Suntree 5000TL
Yes
Single phase

10
11
12
13
14
15
16

Proposed Separate
Capacity

Mention

No. of Inverter
Required

Mention

Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection

Mention

17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22

Minimum
Input
Voltage/Start

up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power

5
1
-25C + 60C

Mention
IP 65
Required
Required
Required

Fan cooling
Yes
Yes
Yes

4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)

Yes
98.2%
250-800VDC

Yes

1000 VDC

DC(Mention)
250 VDC
AC(Mention)

33.3 A

AC 230 V
50 Hz
Mention

230V
Yes

26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night

Mention
Mention
Mention

0.9 (lead) 0.99 (lag)


N/A

29

Mention

23
24
25

5,000 W

N/A

30
31

Reverse Polarity
Protection
Standards should be
provided

32

Supported Standards

33
34

Rated power output


Syncronization w.r.t
Prevailing voltage
level

Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%

Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE

Value
20kW
+/-5%

No

Description

35 Over voltage and under


Voltage tripping conditions

Specified
V

Particulars
6.2.2

Unless
With 6% of

6%

230
u. Clearing time to
abnormal
Voltages
(% of base
Voltage)

I. V<50

II. 50<=V<88

<2.00

N/A

III. 1 10<=V<120

<1.00

N/A

IV. V>120

36 Over and under frequency


Tripping conditions

Hz

4.2.3

N/A

<0.2
6.2.2

Unless
Within 4752

v. Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)

XI.

11.
set

>52

47-52

N/A

<{49.5-47} (adjustable s

0.2
Adjustable
to

point
<0.2-3011

N/A

<0.2-300

37

Capability to withstand

4.1.
8.3

220%

6.3

220%

voltage w.r.t. to the

38

interconnection
Grounding scheme

39

Reconnection time

220%

4. 1.2
s

4.2.6

TT system
Adjustable 6.2.2

TT

>180
>180

E up to
300
40

Limitation of dc injection

.3.1

<0.5

current w.r,t. full


N/A

rated output current

41

at the
point
Output voltage waveform

6.6

50Hz,
sinusoidal

Sine wave

No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code

Name of the Bidder


Signature of the
Bidder : Date
:
Common Seal

Specified
6.11
%
%
%
%
%
%

4.3.3

Required

Particulars
Yes

6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11

<4
<2
<1.5
<0.6
<0.3
<5
Required

N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately

3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI VEYANGODA
Table: 04

Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage

Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention

Maximum Power
Current

Mention

Open Circuit Voltage


Short Circuit Current
Nominal Operating Cell
Temperature(NOCT)

Mention
Mention
Mention

Bidders
response
Yes
No
Yes

If 'No indicate the bidders offered

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
160
30.0V

Yes

30.5V

Yes

8.21A

Yes
Yes

37.6V
8.67C

Yes

45C+2C

Yes

Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box

0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion

Front Glass

3.2 mm tempered hl bh
transmission glass. Low
iron

Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard

12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent

Quality Management

ISO 9001 : 2008 or


Equivalent

Name of the Bidder


:
Signature of the Bidder :
Date
:
Common Seal

Yes
Yes
Yes
Yes

-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)

Yes

IP 65

Yes
Yes

Anodized aluminum alloy

Yes
Yes
Yes
Yes
Yes
Yes
Yes

10%
6/6 pcs

Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER

No

Description

Particulars

Specified

I
2

Name of the supplier


Supplier Registration
No.

Mention
Mention

EWIS Peripherals (Pvt) Ltd

3
4
S

Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports

Mention
Mention
Mention

Solar Leading
China

6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type

PV10130

TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase

Yes
Suntree 20000TL
Yes
Three phase

10
11

Proposed Separate
Capacity

Mention

No. of Inverter
Required

Mention

Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection

Mention

20
2
-25C + 60C

Mention
IP 65
Required
Required
Required

Fan cooling
Yes
Yes
Yes

17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage

4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)

Yes
98.2%
250-800VDC

Minimum
Input

up
21 Voltage/Start
Input Voltage
Maximum
Continues
22
Output Current
23 Rated Grid Voltage
24 Rated Grid Frequency
Maximum AC Output
25 Apparent Power

DC(Mention)

12
13
14
15
16

Yes

1000 VDC
250 VDC

AC(Mention)

33.3 A

AC 230 V
50 Hz
Mention

230V
Yes

26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night

Mention
Mention
Mention

0.9 (lead) 0.99 (lag)


N/A

29

Mention

20,000 W

N/A

30
31

Reverse Polarity
Protection
Standards should be
provided

32

Supported Standards

33
34

Rated power output


Syncronization w.r.t
Prevailing voltage
level

Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%

Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE

Value
20kW
+/-5%

No

Description

35 Over voltage and under


Voltage tripping conditions

Specified
V

Particulars
6.2.2

Unless
With 6% of

6%

230
w. Clearing time to
abnormal
Voltages
(% of base
Voltage)

I. V<50

II. 50<=V<88

<2.00

N/A

III. 1 10<=V<120

<1.00

N/A

IV. V>120

36 Over and under frequency


Tripping conditions

Hz

4.2.3

N/A

<0.2
6.2.2

Unless
Within 4752

x. Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)

XII.

11.
set

>52

47-52

N/A

<{49.5-47} (adjustable s

0.2
Adjustable
to

point
<0.2-3011

N/A

<0.2-300

37

Capability to withstand

4.1.
8.3

220%

6.3

220%

voltage w.r.t. to the

38

interconnection
Grounding scheme

39

Reconnection time

220%

4. 1.2
s

4.2.6

TT system
Adjustable 6.2.2

TT

>180
>180

E up to
300
40

Limitation of dc injection

.3.1

<0.5

current w.r,t. full


N/A

rated output current

41

at the
point
Output voltage waveform

6.6

50Hz,
sinusoidal

Sine wave

No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code

Name of the
Bidder
: Signature
of the Bidder : Date
:
Common Seal

Specified
6.11
%
%
%
%
%
%

4.3.3

Required

Particulars
Yes

6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11

<4
<2
<1.5
<0.6
<0.3
<5
Required

N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately