Escolar Documentos
Profissional Documentos
Cultura Documentos
TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI DEHIWALA
Table: 04
Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage
Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention
Maximum Power
Current
Mention
Mention
Mention
Mention
Bidders
response
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
272
30.0V
Yes
30.5V
Yes
8.21A
Yes
Yes
37.6V
8.67C
Yes
45C+2C
Yes
Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box
0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion
Front Glass
3.2 mm tempered hl bh
transmission glass. Low
iron
Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard
12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent
Quality Management
Yes
Yes
Yes
Yes
-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)
Yes
IP 65
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
10%
6/6 pcs
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No
Description
Particulars
Specified
I
2
Mention
Mention
3
4
S
Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports
Mention
Mention
Mention
Solar Leading
China
6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type
PV10130
TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase
Yes
Suntree17000TL
Yes
Three phase
10
11
12
13
14
15
16
Proposed Separate
Capacity
Mention
No. of Inverter
Required
Mention
Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection
Mention
17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22
Minimum
Input
Voltage/Start
up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power
17KW
4
-25C + 60C
Mention
IP 65
Required
Required
Required
Fan cooling
Yes
Yes
Yes
4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)
Yes
98.2%
250-800VDC
Yes
1000 VDC
DC(Mention)
250 VDC
AC(Mention)
33.3 A
AC 230 V
50 Hz
Mention
230V
Yes
26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night
Mention
Mention
Mention
29
Mention
23
24
25
17,000 W
N/A
30
31
Reverse Polarity
Protection
Standards should be
provided
32
Supported Standards
33
34
Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%
Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE
Value
20kW
+/-5%
No
Description
Specified
V
Particulars
6.2.2
Unless
With 6% of
6%
230
a. Clearing time to
abnormal
Voltages
(% of base
Voltage)
I. V<50
II. 50<=V<88
<2.00
N/A
III. 1 10<=V<120
<1.00
N/A
IV. V>120
Hz
4.2.3
N/A
<0.2
6.2.2
Unless
Within 4752
b. Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)
I.
11.
set
>52
47-52
N/A
<{49.5-47} (adjustable s
0.2
Adjustable
to
point
<0.2-3011
N/A
<0.2-300
37
Capability to withstand
4.1.
8.3
220%
6.3
220%
38
interconnection
Grounding scheme
39
Reconnection time
220%
4. 1.2
s
4.2.6
TT system
Adjustable 6.2.2
TT
>180
>180
E up to
300
40
Limitation of dc injection
.3.1
<0.5
41
at the
point
Output voltage waveform
6.6
50Hz,
sinusoidal
Sine wave
No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code
Specified
6.11
%
%
%
%
%
%
4.3.3
Required
Particulars
Yes
6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11
<4
<2
<1.5
<0.6
<0.3
<5
Required
N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI KANDY
Table: 04
Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage
Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention
Maximum Power
Current
Mention
Mention
Mention
Mention
Bidders
response
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
100
30.0V
Yes
30.5V
Yes
8.21A
Yes
Yes
37.6V
8.67C
Yes
45C+2C
Yes
Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box
0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion
Front Glass
3.2 mm tempered hl bh
transmission glass. Low
iron
Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard
12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent
Quality Management
Yes
Yes
Yes
Yes
-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)
Yes
IP 65
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
10%
6/6 pcs
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No
Description
Particulars
Specified
I
2
Mention
Mention
3
4
S
Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports
Mention
Mention
Mention
Solar Leading
China
6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type
PV10130
TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase
Yes
Suntree 10000TL,15000TL
Yes
Three phase
10
11
12
13
14
15
16
Proposed Separate
Capacity
Mention
No. of Inverter
Required
Mention
Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection
Mention
17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22
Minimum
Input
Voltage/Start
up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power
10KW,15KW
1,1
-25C + 60C
Mention
IP 65
Required
Required
Required
Fan cooling
Yes
Yes
Yes
4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)
Yes
98.2%
250-800VDC
Yes
1000 VDC
DC(Mention)
250 VDC
AC(Mention)
33.3 A
AC 230 V
50 Hz
Mention
230V
Yes
26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night
Mention
Mention
Mention
29
Mention
23
24
25
10,000 W,15000W
N/A
30
31
Reverse Polarity
Protection
Standards should be
provided
32
Supported Standards
33
34
Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%
Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE
Value
20kW
+/-5%
No
Description
Specified
V
Particulars
6.2.2
Unless
With 6% of
6%
230
c. Clearing time to
abnormal
Voltages
(% of base
Voltage)
I. V<50
II. 50<=V<88
<2.00
N/A
III. 1 10<=V<120
<1.00
N/A
IV. V>120
Hz
4.2.3
N/A
<0.2
6.2.2
Unless
Within 4752
d. Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)
II.
11.
set
>52
47-52
N/A
<{49.5-47} (adjustable s
0.2
Adjustable
to
point
<0.2-3011
N/A
<0.2-300
37
Capability to withstand
4.1.
8.3
220%
6.3
220%
38
interconnection
Grounding scheme
39
Reconnection time
220%
4. 1.2
s
4.2.6
TT system
Adjustable 6.2.2
TT
>180
>180
E up to
300
40
Limitation of dc injection
.3.1
<0.5
41
at the
point
Output voltage waveform
6.6
50Hz,
sinusoidal
Sine wave
No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code
Specified
6.11
%
%
%
%
%
%
4.3.3
Required
Particulars
Yes
6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11
<4
<2
<1.5
<0.6
<0.3
<5
Required
N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI GALLE
Table: 04
Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage
Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention
Maximum Power
Current
Mention
Mention
Mention
Mention
Bidders
response
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
172
30.0V
Yes
30.5V
Yes
8.21A
Yes
Yes
37.6V
8.67C
Yes
45C+2C
Yes
Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box
0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion
Front Glass
3.2 mm tempered hl bh
transmission glass. Low
iron
Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard
12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent
Quality Management
Yes
Yes
Yes
Yes
-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)
Yes
IP 65
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
10%
6/6 pcs
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No
Description
Particulars
Specified
I
2
Mention
Mention
3
4
S
Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports
Mention
Mention
Mention
Solar Leading
China
6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type
PV10130
TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase
Yes
Suntree 20000TL
Yes
Three phase
10
11
12
13
14
15
16
Proposed Separate
Capacity
Mention
No. of Inverter
Required
Mention
Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection
Mention
17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22
Minimum
Input
Voltage/Start
up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power
20KW
1
-25C + 60C
Mention
IP 65
Required
Required
Required
Fan cooling
Yes
Yes
Yes
4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)
Yes
98.2%
250-800VDC
Yes
1000 VDC
DC(Mention)
250 VDC
AC(Mention)
33.3 A
AC 230 V
50 Hz
Mention
230V
Yes
26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night
Mention
Mention
Mention
29
Mention
23
24
25
20,000 W
N/A
30
31
Reverse Polarity
Protection
Standards should be
provided
32
Supported Standards
33
34
Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%
Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE
Value
20kW
+/-5%
No
Description
Specified
V
Particulars
6.2.2
Unless
With 6% of
6%
230
e. Clearing time to
abnormal
Voltages
(% of base
Voltage)
I. V<50
II. 50<=V<88
<2.00
N/A
III. 1 10<=V<120
<1.00
N/A
IV. V>120
Hz
4.2.3
N/A
<0.2
6.2.2
Unless
Within 4752
f.
Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)
III.
11.
set
>52
47-52
N/A
<{49.5-47} (adjustable s
0.2
Adjustable
to
point
<0.2-3011
N/A
<0.2-300
37
Capability to withstand
4.1.
8.3
220%
6.3
220%
38
interconnection
Grounding scheme
39
Reconnection time
220%
4. 1.2
s
4.2.6
TT system
Adjustable 6.2.2
TT
>180
>180
E up to
300
40
Limitation of dc injection
.3.1
<0.5
41
at the
point
Output voltage waveform
6.6
50Hz,
sinusoidal
Sine wave
No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code
Specified
6.11
%
%
%
%
%
%
4.3.3
Required
Particulars
Yes
6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11
<4
<2
<1.5
<0.6
<0.3
<5
Required
N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI AMPARA
Table: 04
Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage
Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention
Maximum Power
Current
Mention
Mention
Mention
Mention
Bidders
response
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
240
30.0V
Yes
30.5V
Yes
8.21A
Yes
Yes
37.6V
8.67C
Yes
45C+2C
Yes
Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box
0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion
Front Glass
3.2 mm tempered hl bh
transmission glass. Low
iron
Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard
12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent
Quality Management
Yes
Yes
Yes
Yes
-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)
Yes
IP 65
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
10%
6/6 pcs
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No
Description
Particulars
Specified
I
2
Mention
Mention
3
4
S
Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports
Mention
Mention
Mention
Solar Leading
China
6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type
PV10130
TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase
Yes
Suntree 20000TL
Yes
Three phase
10
11
12
13
14
15
16
Proposed Separate
Capacity
Mention
No. of Inverter
Required
Mention
Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection
Mention
17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22
Minimum
Input
Voltage/Start
up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power
20KW
3
-25C + 60C
Mention
IP 65
Required
Required
Required
Fan cooling
Yes
Yes
Yes
4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)
Yes
98.2%
250-800VDC
Yes
1000 VDC
DC(Mention)
250 VDC
AC(Mention)
33.3 A
AC 230 V
50 Hz
Mention
230V
Yes
26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night
Mention
Mention
Mention
29
Mention
23
24
25
20,000 W
N/A
30
31
Reverse Polarity
Protection
Standards should be
provided
32
Supported Standards
33
34
Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%
Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE
Value
20kW
+/-5%
No
Description
Specified
V
Particulars
6.2.2
Unless
With 6% of
6%
230
g. Clearing time to
abnormal
Voltages
(% of base
Voltage)
I. V<50
II. 50<=V<88
<2.00
N/A
III. 1 10<=V<120
<1.00
N/A
IV. V>120
Hz
4.2.3
N/A
<0.2
6.2.2
Unless
Within 4752
h. Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)
IV.
11.
set
>52
47-52
N/A
<{49.5-47} (adjustable s
0.2
Adjustable
to
point
<0.2-3011
N/A
<0.2-300
37
Capability to withstand
4.1.
8.3
220%
6.3
220%
38
interconnection
Grounding scheme
39
Reconnection time
220%
4. 1.2
s
4.2.6
TT system
Adjustable 6.2.2
TT
>180
>180
E up to
300
40
Limitation of dc injection
.3.1
<0.5
41
at the
point
Output voltage waveform
6.6
50Hz,
sinusoidal
Sine wave
No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code
Specified
6.11
%
%
%
%
%
%
4.3.3
Required
Particulars
Yes
6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11
<4
<2
<1.5
<0.6
<0.3
<5
Required
N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI JAFFNA
Table: 04
Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage
Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention
Maximum Power
Current
Mention
Mention
Mention
Mention
Bidders
response
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
120
30.0V
Yes
30.5V
Yes
8.21A
Yes
Yes
37.6V
8.67C
Yes
45C+2C
Yes
Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box
0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion
Front Glass
3.2 mm tempered hl bh
transmission glass. Low
iron
Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard
12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent
Quality Management
Yes
Yes
Yes
Yes
-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)
Yes
IP 65
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
10%
6/6 pcs
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No
Description
Particulars
Specified
I
2
Mention
Mention
3
4
S
Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports
Mention
Mention
Mention
Solar Leading
China
6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type
PV10130
TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase
Yes
Suntree 30000TL
Yes
Three phase
10
11
12
13
14
15
16
Proposed Separate
Capacity
Mention
No. of Inverter
Required
Mention
Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection
Mention
17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22
Minimum
Input
Voltage/Start
up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power
30
1
-25C + 60C
Mention
IP 65
Required
Required
Required
Fan cooling
Yes
Yes
Yes
4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)
Yes
98.2%
250-800VDC
Yes
1000 VDC
DC(Mention)
250 VDC
AC(Mention)
33.3 A
AC 230 V
50 Hz
Mention
230V
Yes
26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night
Mention
Mention
Mention
29
Mention
23
24
25
30,000 W
N/A
30
31
Reverse Polarity
Protection
Standards should be
provided
32
Supported Standards
33
34
Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%
Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE
Value
20kW
+/-5%
No
Description
Specified
V
Particulars
6.2.2
Unless
With 6% of
6%
230
i.
Clearing time to
abnormal
Voltages
(% of base
Voltage)
I. V<50
II. 50<=V<88
<2.00
N/A
III. 1 10<=V<120
<1.00
N/A
IV. V>120
Hz
4.2.3
N/A
<0.2
6.2.2
Unless
Within 4752
j.
Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)
V.
11.
set
>52
47-52
N/A
<{49.5-47} (adjustable s
0.2
Adjustable
to
point
<0.2-3011
N/A
<0.2-300
37
Capability to withstand
4.1.
8.3
220%
6.3
220%
38
interconnection
Grounding scheme
39
Reconnection time
220%
4. 1.2
s
4.2.6
TT system
Adjustable 6.2.2
TT
>180
>180
E up to
300
40
Limitation of dc injection
.3.1
<0.5
41
at the
point
Output voltage waveform
6.6
50Hz,
sinusoidal
Sine wave
No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code
Specified
6.11
%
%
%
%
%
%
4.3.3
Required
Particulars
Yes
6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11
<4
<2
<1.5
<0.6
<0.3
<5
Required
N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI BATTICALOA
Table: 04
Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage
Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention
Maximum Power
Current
Mention
Mention
Mention
Mention
Bidders
response
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
20
30.0V
Yes
30.5V
Yes
8.21A
Yes
Yes
37.6V
8.67C
Yes
45C+2C
Yes
Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box
0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion
Front Glass
3.2 mm tempered hl bh
transmission glass. Low
iron
Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard
12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent
Quality Management
Yes
Yes
Yes
Yes
-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)
Yes
IP 65
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
10%
6/6 pcs
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No
Description
Particulars
Specified
I
2
Mention
Mention
3
4
S
Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports
Mention
Mention
Mention
Solar Leading
China
6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type
PV10130
TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase
Yes
Suntree 5000TL
Yes
Single phase
10
11
12
13
14
15
16
Proposed Separate
Capacity
Mention
No. of Inverter
Required
Mention
Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection
Mention
17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22
Minimum
Input
Voltage/Start
up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power
5KW
1
-25C + 60C
Mention
IP 65
Required
Required
Required
Fan cooling
Yes
Yes
Yes
4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)
Yes
98.2%
250-800VDC
Yes
1000 VDC
DC(Mention)
250 VDC
AC(Mention)
33.3 A
AC 230 V
50 Hz
Mention
230V
Yes
26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night
Mention
Mention
Mention
29
Mention
23
24
25
5,000 W
N/A
30
31
Reverse Polarity
Protection
Standards should be
provided
32
Supported Standards
33
34
Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%
Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE
Value
20kW
+/-5%
No
Description
Specified
V
Particulars
6.2.2
Unless
With 6% of
6%
230
k. Clearing time to
abnormal
Voltages
(% of base
Voltage)
I. V<50
II. 50<=V<88
<2.00
N/A
III. 1 10<=V<120
<1.00
N/A
IV. V>120
Hz
4.2.3
N/A
<0.2
6.2.2
Unless
Within 4752
l.
Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)
VI.
11.
set
>52
47-52
N/A
<{49.5-47} (adjustable s
0.2
Adjustable
to
point
<0.2-3011
N/A
<0.2-300
37
Capability to withstand
4.1.
8.3
220%
6.3
220%
38
interconnection
Grounding scheme
39
Reconnection time
220%
4. 1.2
s
4.2.6
TT system
Adjustable 6.2.2
TT
>180
>180
E up to
300
40
Limitation of dc injection
.3.1
<0.5
41
at the
point
Output voltage waveform
6.6
50Hz,
sinusoidal
Sine wave
No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code
Specified
6.11
%
%
%
%
%
%
4.3.3
Required
Particulars
Yes
6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11
<4
<2
<1.5
<0.6
<0.3
<5
Required
N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI KURUNEGALA
Table: 04
Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage
Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention
Maximum Power
Current
Mention
Mention
Mention
Mention
Bidders
response
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
160
30.0V
Yes
30.5V
Yes
8.21A
Yes
Yes
37.6V
8.67C
Yes
45C+2C
Yes
Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box
0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion
Front Glass
3.2 mm tempered hl bh
transmission glass. Low
iron
Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard
12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent
Quality Management
Yes
Yes
Yes
Yes
-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)
Yes
IP 65
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
10%
6/6 pcs
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No
Description
Particulars
Specified
I
2
Mention
Mention
3
4
S
Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports
Mention
Mention
Mention
Solar Leading
China
6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type
PV10130
TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase
Yes
Suntree 20000TL
Yes
Three phase
10
11
12
13
14
15
16
Proposed Separate
Capacity
Mention
No. of Inverter
Required
Mention
Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection
Mention
17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22
Minimum
Input
Voltage/Start
up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power
20KW
2
-25C + 60C
Mention
IP 65
Required
Required
Required
Fan cooling
Yes
Yes
Yes
4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)
Yes
98.2%
250-800VDC
Yes
1000 VDC
DC(Mention)
250 VDC
AC(Mention)
33.3 A
AC 230 V
50 Hz
Mention
230V
Yes
26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night
Mention
Mention
Mention
29
Mention
23
24
25
20,000 W
N/A
30
31
Reverse Polarity
Protection
Standards should be
provided
32
Supported Standards
33
34
Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%
Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE
Value
20kW
+/-5%
No
Description
Specified
V
Particulars
6.2.2
Unless
With 6% of
6%
230
m. Clearing time to
abnormal
Voltages
(% of base
Voltage)
I. V<50
II. 50<=V<88
<2.00
N/A
III. 1 10<=V<120
<1.00
N/A
IV. V>120
Hz
4.2.3
N/A
<0.2
6.2.2
Unless
Within 4752
n. Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)
VII.
11.
set
>52
47-52
N/A
<{49.5-47} (adjustable s
0.2
Adjustable
to
point
<0.2-3011
N/A
<0.2-300
37
Capability to withstand
4.1.
8.3
220%
6.3
220%
38
interconnection
Grounding scheme
39
Reconnection time
220%
4. 1.2
s
4.2.6
TT system
Adjustable 6.2.2
TT
>180
>180
E up to
300
40
Limitation of dc injection
.3.1
<0.5
41
at the
point
Output voltage waveform
6.6
50Hz,
sinusoidal
Sine wave
No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code
Specified
6.11
%
%
%
%
%
%
4.3.3
Required
Particulars
Yes
6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11
<4
<2
<1.5
<0.6
<0.3
<5
Required
N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI KEGALLE
Table: 04
Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage
Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention
Maximum Power
Current
Mention
Mention
Mention
Mention
Bidders
response
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
32
30.0V
Yes
30.5V
Yes
8.21A
Yes
Yes
37.6V
8.67C
Yes
45C+2C
Yes
Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box
0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion
Front Glass
3.2 mm tempered hl bh
transmission glass. Low
iron
Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard
12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent
Quality Management
Yes
Yes
Yes
Yes
-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)
Yes
IP 65
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
10%
6/6 pcs
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No
Description
Particulars
Specified
I
2
Mention
Mention
3
4
S
Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports
Mention
Mention
Mention
Solar Leading
China
6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type
PV10130
TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase
Yes
Suntree 8000TL
Yes
Three phase
10
11
12
13
14
15
16
Proposed Separate
Capacity
Mention
No. of Inverter
Required
Mention
Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection
Mention
17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22
Minimum
Input
Voltage/Start
up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power
8
1
-25C + 60C
Mention
IP 65
Required
Required
Required
Fan cooling
Yes
Yes
Yes
4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)
Yes
98.2%
250-800VDC
Yes
1000 VDC
DC(Mention)
250 VDC
AC(Mention)
33.3 A
AC 230 V
50 Hz
Mention
230V
Yes
26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night
Mention
Mention
Mention
29
Mention
23
24
25
8,000 W
N/A
30
31
Reverse Polarity
Protection
Standards should be
provided
32
Supported Standards
33
34
Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%
Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE
Value
20kW
+/-5%
No
Description
Specified
V
Particulars
6.2.2
Unless
With 6% of
6%
230
o. Clearing time to
abnormal
Voltages
(% of base
Voltage)
I. V<50
II. 50<=V<88
<2.00
N/A
III. 1 10<=V<120
<1.00
N/A
IV. V>120
Hz
4.2.3
N/A
<0.2
6.2.2
Unless
Within 4752
p. Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)
VIII.
11.
set
>52
47-52
N/A
<{49.5-47} (adjustable s
0.2
Adjustable
to
point
<0.2-3011
N/A
<0.2-300
37
Capability to withstand
4.1.
8.3
220%
6.3
220%
38
interconnection
Grounding scheme
39
Reconnection time
220%
4. 1.2
s
4.2.6
TT system
Adjustable 6.2.2
TT
>180
>180
E up to
300
40
Limitation of dc injection
.3.1
<0.5
41
at the
point
Output voltage waveform
6.6
50Hz,
sinusoidal
Sine wave
No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code
Specified
6.11
%
%
%
%
%
%
4.3.3
Required
Particulars
Yes
6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11
<4
<2
<1.5
<0.6
<0.3
<5
Required
N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI TRINCOMALEE
Table: 04
Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage
Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention
Maximum Power
Current
Mention
Mention
Mention
Mention
Bidders
response
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
160
30.0V
Yes
30.5V
Yes
8.21A
Yes
Yes
37.6V
8.67C
Yes
45C+2C
Yes
Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box
0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion
Front Glass
3.2 mm tempered hl bh
transmission glass. Low
iron
Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard
12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent
Quality Management
Yes
Yes
Yes
Yes
-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)
Yes
IP 65
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
10%
6/6 pcs
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No
Description
Particulars
Specified
I
2
Mention
Mention
3
4
S
Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports
Mention
Mention
Mention
Solar Leading
China
6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type
PV10130
TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase
Yes
Suntree 20000TL
Yes
Three phase
10
11
12
13
14
15
16
Proposed Separate
Capacity
Mention
No. of Inverter
Required
Mention
Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection
Mention
17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22
Minimum
Input
Voltage/Start
up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power
20KW
2
-25C + 60C
Mention
IP 65
Required
Required
Required
Fan cooling
Yes
Yes
Yes
4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)
Yes
98.2%
250-800VDC
Yes
1000 VDC
DC(Mention)
250 VDC
AC(Mention)
33.3 A
AC 230 V
50 Hz
Mention
230V
Yes
26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night
Mention
Mention
Mention
29
Mention
23
24
25
20,000 W
N/A
30
31
Reverse Polarity
Protection
Standards should be
provided
32
Supported Standards
33
34
Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%
Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE
Value
20kW
+/-5%
No
Description
Specified
V
Particulars
6.2.2
Unless
With 6% of
6%
230
q. Clearing time to
abnormal
Voltages
(% of base
Voltage)
I. V<50
II. 50<=V<88
<2.00
N/A
III. 1 10<=V<120
<1.00
N/A
IV. V>120
Hz
4.2.3
N/A
<0.2
6.2.2
Unless
Within 4752
r.
Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)
IX.
11.
set
>52
47-52
N/A
<{49.5-47} (adjustable s
0.2
Adjustable
to
point
<0.2-3011
N/A
<0.2-300
37
Capability to withstand
4.1.
8.3
220%
6.3
220%
38
interconnection
Grounding scheme
39
Reconnection time
220%
4. 1.2
s
4.2.6
TT system
Adjustable 6.2.2
TT
>180
>180
E up to
300
40
Limitation of dc injection
.3.1
<0.5
41
at the
point
Output voltage waveform
6.6
50Hz,
sinusoidal
Sine wave
No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code
Specified
6.11
%
%
%
%
%
%
4.3.3
Required
Particulars
Yes
6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11
<4
<2
<1.5
<0.6
<0.3
<5
Required
N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI BADULLA
Table: 04
Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage
Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention
Maximum Power
Current
Mention
Mention
Mention
Mention
Bidders
response
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
60
30.0V
Yes
30.5V
Yes
8.21A
Yes
Yes
37.6V
8.67C
Yes
45C+2C
Yes
Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box
0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion
Front Glass
3.2 mm tempered hl bh
transmission glass. Low
iron
Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard
12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent
Quality Management
Yes
Yes
Yes
Yes
-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)
Yes
IP 65
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
10%
6/6 pcs
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No
Description
Particulars
Specified
I
2
Mention
Mention
3
4
S
Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports
Mention
Mention
Mention
Solar Leading
China
6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type
PV10130
TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase
Yes
Suntree 15000TL
Yes
Three phase
10
11
12
13
14
15
16
Proposed Separate
Capacity
Mention
No. of Inverter
Required
Mention
Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection
Mention
17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22
Minimum
Input
Voltage/Start
up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power
15KW
1
-25C + 60C
Mention
IP 65
Required
Required
Required
Fan cooling
Yes
Yes
Yes
4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)
Yes
98.2%
250-800VDC
Yes
1000 VDC
DC(Mention)
250 VDC
AC(Mention)
33.3 A
AC 230 V
50 Hz
Mention
230V
Yes
26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night
Mention
Mention
Mention
29
Mention
23
24
25
15,000 W
N/A
30
31
Reverse Polarity
Protection
Standards should be
provided
32
Supported Standards
33
34
Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%
Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE
Value
20kW
+/-5%
No
Description
Specified
V
Particulars
6.2.2
Unless
With 6% of
6%
230
s. Clearing time to
abnormal
Voltages
(% of base
Voltage)
I. V<50
II. 50<=V<88
<2.00
N/A
III. 1 10<=V<120
<1.00
N/A
IV. V>120
Hz
4.2.3
N/A
<0.2
6.2.2
Unless
Within 4752
t.
Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)
X.
11.
set
>52
47-52
N/A
<{49.5-47} (adjustable s
0.2
Adjustable
to
point
<0.2-3011
N/A
<0.2-300
37
Capability to withstand
4.1.
8.3
220%
6.3
220%
38
interconnection
Grounding scheme
39
Reconnection time
220%
4. 1.2
s
4.2.6
TT system
Adjustable 6.2.2
TT
>180
>180
E up to
300
40
Limitation of dc injection
.3.1
<0.5
41
at the
point
Output voltage waveform
6.6
50Hz,
sinusoidal
Sine wave
No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code
Specified
6.11
%
%
%
%
%
%
4.3.3
Required
Particulars
Yes
6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11
<4
<2
<1.5
<0.6
<0.3
<5
Required
N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI TANGALLE
Table: 04
Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage
Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention
Maximum Power
Current
Mention
Mention
Mention
Mention
Bidders
response
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
20
30.0V
Yes
30.5V
Yes
8.21A
Yes
Yes
37.6V
8.67C
Yes
45C+2C
Yes
Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box
0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion
Front Glass
3.2 mm tempered hl bh
transmission glass. Low
iron
Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard
12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent
Quality Management
Yes
Yes
Yes
Yes
-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)
Yes
IP 65
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
10%
6/6 pcs
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No
Description
Particulars
Specified
I
2
Mention
Mention
3
4
S
Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports
Mention
Mention
Mention
Solar Leading
China
6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type
PV10130
TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase
Yes
Suntree 5000TL
Yes
Single phase
10
11
12
13
14
15
16
Proposed Separate
Capacity
Mention
No. of Inverter
Required
Mention
Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection
Mention
17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
21
22
Minimum
Input
Voltage/Start
up
Input Voltage
Maximum
Continues
Output Current
Rated Grid Voltage
Rated Grid Frequency
Maximum AC Output
Apparent Power
5
1
-25C + 60C
Mention
IP 65
Required
Required
Required
Fan cooling
Yes
Yes
Yes
4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)
Yes
98.2%
250-800VDC
Yes
1000 VDC
DC(Mention)
250 VDC
AC(Mention)
33.3 A
AC 230 V
50 Hz
Mention
230V
Yes
26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night
Mention
Mention
Mention
29
Mention
23
24
25
5,000 W
N/A
30
31
Reverse Polarity
Protection
Standards should be
provided
32
Supported Standards
33
34
Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%
Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE
Value
20kW
+/-5%
No
Description
Specified
V
Particulars
6.2.2
Unless
With 6% of
6%
230
u. Clearing time to
abnormal
Voltages
(% of base
Voltage)
I. V<50
II. 50<=V<88
<2.00
N/A
III. 1 10<=V<120
<1.00
N/A
IV. V>120
Hz
4.2.3
N/A
<0.2
6.2.2
Unless
Within 4752
v. Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)
XI.
11.
set
>52
47-52
N/A
<{49.5-47} (adjustable s
0.2
Adjustable
to
point
<0.2-3011
N/A
<0.2-300
37
Capability to withstand
4.1.
8.3
220%
6.3
220%
38
interconnection
Grounding scheme
39
Reconnection time
220%
4. 1.2
s
4.2.6
TT system
Adjustable 6.2.2
TT
>180
>180
E up to
300
40
Limitation of dc injection
.3.1
<0.5
41
at the
point
Output voltage waveform
6.6
50Hz,
sinusoidal
Sine wave
No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code
Specified
6.11
%
%
%
%
%
%
4.3.3
Required
Particulars
Yes
6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11
<4
<2
<1.5
<0.6
<0.3
<5
Required
N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI VEYANGODA
Table: 04
Descriptions
Make
Model No
Country of Origin
Dimension
Total Area Required
Weight
Output Cables
Panel Capacity
No. of Module Required
Panel Voltage(Nominal)
Maximum Power
Voltage
Required
Specification
Mention
Mention
Mention
Mention
Mention
Mention
Mention
250 Wp or Grater
Mention
Mention
Mention
Maximum Power
Current
Mention
Mention
Mention
Mention
Bidders
response
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Solar Leading
SL6P60-250W
China
1640x992x40mm
1.626m2
19.0kg
TUV 1x4mm2 / UL12AWG; Length, 900mm
250WP
160
30.0V
Yes
30.5V
Yes
8.21A
Yes
Yes
37.6V
8.67C
Yes
45C+2C
Yes
Working Temperature
Average Cell Efficiency
Module Efficiency
Cell Type
Junction Box
0' C to 85" C
Minimum 16'll
Mention
Mono/Poly
Sealable and moisture
resistance
IP65
Aluminum or resist to
corrosion
Front Glass
3.2 mm tempered hl bh
transmission glass. Low
iron
Product Warranty
Linear Performance
Expected Life time
Number of bypass
diodes
Standard
12 Years or more
Depreciation Rate. . ... ...
% Years
25
Mention
IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent
Quality Management
Yes
Yes
Yes
Yes
-40 ~ +85C
17.98%
15.37%
Poly 156x156mm (6 inch)
Yes
IP 65
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
10%
6/6 pcs
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No
Description
Particulars
Specified
I
2
Mention
Mention
3
4
S
Inverter manufacturer
Country of origin
Independent Agency
of submitting
test reports
Mention
Mention
Mention
Solar Leading
China
6 1s an accredited agency
7 Model No.
8 Inverter Technology
Inverter Type
PV10130
TUV/ROHS/ISO
Mention
Mention
Transformer less
Single or 3 Phase
Yes
Suntree 20000TL
Yes
Three phase
10
11
Proposed Separate
Capacity
Mention
No. of Inverter
Required
Mention
Operating Temperature
Range
Cooling Method
Protection Rating
DC Protection
AC Protection
Lightning
Surge
Protection
Mention
20
2
-25C + 60C
Mention
IP 65
Required
Required
Required
Fan cooling
Yes
Yes
Yes
17 Relative Humidity
18 Maximum Efficiency
19 MPPT Voltage Range
Maximum
Input
20 Voltage
4% - I 04 0 o
Minimum 97%
DC Volt Minimum to Maximum
DC(Mention)
Yes
98.2%
250-800VDC
Minimum
Input
up
21 Voltage/Start
Input Voltage
Maximum
Continues
22
Output Current
23 Rated Grid Voltage
24 Rated Grid Frequency
Maximum AC Output
25 Apparent Power
DC(Mention)
12
13
14
15
16
Yes
1000 VDC
250 VDC
AC(Mention)
33.3 A
AC 230 V
50 Hz
Mention
230V
Yes
26 Power Factor
27 Short Circuit Proof
Internal Consumption
28 at Night
Mention
Mention
Mention
29
Mention
20,000 W
N/A
30
31
Reverse Polarity
Protection
Standards should be
provided
32
Supported Standards
33
34
Mention
Safety, EMC Emission, EMC Immunity, EMC
Harmonic & Flicker, Automatics Grid
Disconnections
IEEE 1547-2003
Grid Code/CEB
Unit
Ref.
Value
Ref.
Value
kW
20
Hz
50
%
4.1.3
+/-5%
Yes
Yes
Inverter
Ref. of test certificates
IEC, IEEE
Value
20kW
+/-5%
No
Description
Specified
V
Particulars
6.2.2
Unless
With 6% of
6%
230
w. Clearing time to
abnormal
Voltages
(% of base
Voltage)
I. V<50
II. 50<=V<88
<2.00
N/A
III. 1 10<=V<120
<1.00
N/A
IV. V>120
Hz
4.2.3
N/A
<0.2
6.2.2
Unless
Within 4752
x. Clearing time to
Abnormal
frequencies
<30 Kw (in Hz)
XII.
11.
set
>52
47-52
N/A
<{49.5-47} (adjustable s
0.2
Adjustable
to
point
<0.2-3011
N/A
<0.2-300
37
Capability to withstand
4.1.
8.3
220%
6.3
220%
38
interconnection
Grounding scheme
39
Reconnection time
220%
4. 1.2
s
4.2.6
TT system
Adjustable 6.2.2
TT
>180
>180
E up to
300
40
Limitation of dc injection
.3.1
<0.5
41
at the
point
Output voltage waveform
6.6
50Hz,
sinusoidal
Sine wave
No Description
42 Power quality
Measurements as per IEC
61400-21
43 Harmonic Distortion
a. H<11
b. 11<h<17
c. 17<h<23
d. 23<h<35
e. 35<h
f. THD
44 Emission of inter
harmonic Currents from
the power electronic
converter as per grid
code
Name of the
Bidder
: Signature
of the Bidder : Date
:
Common Seal
Specified
6.11
%
%
%
%
%
%
4.3.3
Required
Particulars
Yes
6.7
<4
<2
<1.5
<0.6
<0.3
<5
6.11
<4
<2
<1.5
<0.6
<0.3
<5
Required
N/A
N/A
N/A
N/A
N/A
<3%
Submit
separately