ELECTRONIC MOTOR & OVERLOAD PROTECTION RELAYS

Phase Angle Motor Protection Relays

Mainly used for borehole protection with liquid level control tank filling. DIN mount.

MP820/230VAC-SP
MP825/230VAC-SP
MP830/230VAC-SP
MP830/400VAC-SP
MP830/525VAC-SP
MP835/230VAC-SP
MP835/400VAC-SP

MP830



MP835

Common Features

Relay/ Over load sensing


Under/ Over load sensing
Latching on overload conditions.
Liquid level control. 50k
Adjustable restart time: 15mins - 24hrs
Reset lockout: Max 3 resets
For single phase motor 230VAC
per 15mins
Restart timer 15mins-24hrs (ADS)
Auto calibration of overload voltage and underload voltage Auto calibration of over/ under
current and over/ under voltage
limits with latching on these conditions
Latching on overload conditions
For single phase motors 230VAC
Microprocessor-based technology
Direct in-line current sensing of motor, up to 3.7kW.
Start-up delay: 3 seconds fixed,
Phase sequence and phase failure detection
extended time available on request
Latching on overload conditions.
Response delay on overload 3
Adjustable restart time: 15mins - 24hrs
seconds
Direct in-line current sensing of motor, up to 3.7kW.
Auto calibration of overload voltage and underload voltage Response delay on voltage 1
second
Phase sequence and phase failure detection
Latching on under and overload conditions
RHE
Underload sensitivity adjustment

Electronic Overload Protection Relays


Code
Current Range
OL

CSMPA-60-T 6A
CSMPA-60-T 60A
CSMPA-22-3S-5A0
CSMPA-22-3S5A
CSMPA-40R 1-SA
CSMPA-40R 5A
CSMPM-06-SZ
CSMPM-60-SZ

CSMPA-60-T

CSMPA-40

LR

5 - 60

0.3 - 1.5*

1-5

0.3 - 1.5

1-5

PU

PR STL UL ALT GF

0.5 - 6

TRIP DISP CONTROL


TYPE TYPE VOLTAGE
D

LED

LED

LED

5 - 60

LED

LED

LED

I+D

SSD

I+D

SSD

Key: OL: over current


PL: Phase Loss
LR: Locked Rotor PU: Phase Unbalance PR: Phase Reverse

UL: Under Current ALT: Alert (60 - 110%) GF: Ground Fault I: Inverse Time
D: Definite Time
- : not available
LED: Red & Green
SSD: Seven Segment Display

Accessories
Code
CSMPM - 1.5M
CSMPM - 4M

Description
1.5m ext cable for CSMPM - 06/60-S/ S1/SZ
4m ext cable for CSMPM - 06/60-S/S1/SZ

*NOTES: CSMPA22 - models with current range 1 - 5A can be used up


to 600A with suitable ratios CTs having 5A secondary, class 1 accuracy.

CSMPM-06-SZ

Protection Features for Newelec Relays

0.5 - 6

PL

Features

DS1

LA

KB

KA

KC MA KD/KE

Max. current (w/o ext. CTs) 60A 250A 25A 25A 25A 250A 50A
Thermal memory



Locked rotor (at start)







Jam (from running)


Unbalanced load



Phase loss





User select O/L auto reset



(1) (1)
(1)
Under current


Restart timer

Restart contact

Phase rotation

Over voltage

110/220

110/220

110 to 260

110 to 260

110 to 260

110 to 260
110/220
110/220

STL: Stalling
: Available

Ground Fault Core Balance Transformers


Code
Hole DIA
Z-CT D30
30mm
Z-CT D50
50mm
Z-CT D65
65mm
Z-CT D80
80mm

DS1 LA

KB KA

KC MA KD/KE

Max. current (w/o ext. CTs) 60A 250A 25A 25A 25A 250A 50A
Under voltage

Voltage phase symmetry



LED trip indication







Door mount control option

MCCB fail - upstream tripping


MCCB/Contactor co-ordination
Earth leakage* (core incl. up to 250A)

Protocol option
3 x PTC100 inputs
Totalised running hours
Last 4 faults memory

CIRCUIT BREAKERS, FUSE GEAR & ISOLATORS


MP825

*10A
*10A
* 8A
* 8A
* 8A
* 8A
* 8A

Single phase motor protection relay up to 1.1kW


Single phase motor protection relay above 1.1kW
Three phase motor protection relay up to 3.7kW
Three phase motor protection relay up to 3.7kW
Three phase motor protection relay up to 3.7kW
Three phase motor protection relay up to 3.7kW
Three phase motor protection relay up to 3.7kW
For higher load current use 5 Amp CT to achieve accurate calibration

Exclusive Features

Direct in-line current sensing of motor, up to 1.1kW.

MP820


Max. Current
Continuous

Description

Code

*For MA, CB CT is internal up to 250A. For over 250A use external core balance CT, see page 167. (1) 3 starts per hour limit in auto mode