Você está na página 1de 6

No.

11 kV Feeders
CT Ratio: 100 200 400.

Core Number

1 Core 1
2 Core 2
33 kV Feeders
CT Ratios: 60 120 240, 125 250 500.
1 Core 1
2 Core 2
11 kV side of 132 kV Class Transformers
CT Ratios: 200 400 800, 1200.
1 Core 1
2 Core 2
3 Core 3
33 kV side of 132 kV Class Transformers
CT Ratios: 150 300 600, 250 500.
1 Core
2 Core
3 Core
4 Core
5 Core

1
2
3
4
5

132 kV Feeders at 132 kV GSS


CT Ratios: 100 200 400, 250 500.
1 Core 1
2 Core 2
3 Core 3
132 kV Feeders at 220 kV GSS
CT Ratios: 100 200 400, 250 500.
1 Core
2 Core
3 Core
4 Core

1
2
3
4

132 kV side of 132 kV class Transformers


CT Ratios: 60 120 240, 125 250 500.
1 Core 1
2 Core 2
3 Core 3
132 kV side of 220 kV class Transformers
CT Ratios: 150 300 600, 250 500.
1 Core
2 Core
3 Core
4 Core
220 kV Feeders

1
2
3
4

CT Ratios: 200 400 800, 400 800.


1 Core 1
2 Core
3 Core
4 Core
5 Core

2
3
4
5

1 Core
2 Core
3 Core
4 Core
5 Core

1
2
3
4
5

220 kV side of 220 kV class Transformers


CT Ratio: 150 300 600, 400 800.

220 kV side of 400 kV class Transformers


CT Ratio: 500 1000 2000.
1 Core 1

2 Core
3 Core
4 Core
5 Core

2
3
4
5

400 kV Bays
CT Ratio: 500 1000 2000.
1 Core 1

2 Core
3 Core
4 Core
5 Core

2
3
4
5

Accuracy Class

Purpose

5P20
0.5

Over current & Earth fault Protection


Metering

5P20

Over current & Earth fault Protection


0.5 Metering

PS
5P20
0.5

Differential Protection
Over current & Earth fault Protection
Metering: Indication & Energy Meter

PS
5P20
0.5/ 1.0
0.2
0.2

Differential Protection
Over current & Earth fault Protection
Metering: Indication
Metering: Main Energy Meter
Metering: Check Energy Meter

PS
PS / 5P20
0.5

Distance Protection
Over current & Earth fault Protection
Metering: Indication & Energy Meter

PS
PS / 5P20
0.5
PS / 5P20

Distance Protection
Over current & Earth fault Protection
Metering: Indication & Energy Meter
Bus Bar Protection

PS
PS / 5P20
0.5

Differential Protection
Over current & Earth fault Protection
Metering: Indication & Energy Meter

PS
PS / 5P20
0.5
PS / 5P20

Differential Protection
Over current & Earth fault Protection
Metering: Indication & Energy Meter
Bus Bar Protection

PS

Distance Protection Main - 1

PS
0.5
PS
PS

Distance Protection Main 2,


Over current, Earth fault and LBB Protections
Metering
Bus Bar Protection (Main Zone)
Bus Bar Protection (Check Zone)

PS
PS
0.5
PS
PS

Differential Protection
Over current, Earth fault and LBB Protections
Metering
Bus Bar Protection (Main Zone)
Bus Bar Protection (Check Zone)

PS

Differential Protection Main 1 / Distance Protection Main 1

PS
0.5
PS
PS

Differential Protection Main 2 DistanceProtection Main 2, /


Over current, Earth faultand LBB Prote ctions
Metering
Bus Bar Protection (Main Zone)
Bus Bar Protection (Check Zone)

PS

Differential Protection Main 1 /


Distance Protection Main - 1

PS
0.5
PS
PS

Differential Protection Main 2 /


Distance Protection Main 2, Over current, Earth fault and LBB
Protections
Metering
Bus Bar Protection (Main Zone) except for CTs in Tie CB Bay
Bus Bar Protection (Check Zone) except for CTs in Tie CB Bay

DEVICE NUMBER
2
3
21
25
27
30
32
37
40
46
49
50
51
52
52a
52b
55
56
59
60
64
67
68
74
76
78
79
81
81U
81O
83
86
87
87G
87GT
87U
87NT
95
99
186
186

UNIVERSAL NOMENCLATURE
Time delay relay
Interlocking relay
Distance relay
Check synchronizing relay
Under voltage relay
Annunciator relay
Directional power (Reverse power) relay
Low forward power relay
Field failure (loss of excitation) relay
Negative phase sequence relay
Machine or Transformer Thermal relay
Instantaneous Over current relay
A.C IDMT over current relay
Circuit breaker
Circuit breaker Auxiliary switch Normally open (a contact)
Circuit breaker Auxiliary switch Normally closed (b contact)
Power Factor relay
Field Application relay
Over voltage relay
Voltage or current balance relay
Earth fault relay
Directional relay
Locking relay
Alarm relay
D.C Over current relay
Phase angle measuring or out of step relay
AC Auto reclose relay
Frequency relay
Under frequency relay
Over frequency relay
Automatic selective control or transfer relay
CTripping Relay
Differential relay
Generator differential relay
Overall differential relay
UAT differential relay
Restricted earth fault relay
Trip circuit supervision relay
Over flux relay
A Auto reclose lockout relay
B Auto reclose lockout relay

Você também pode gostar