DISEO DE UN SISTEMA DE RIEGO POR GOTEO EN LA
LOCALIDAD EL PROGRESO, DISTRITO DE PATAPO, PROVINCIA
DE CHICLAYO, REGION LAMBAYEQUE
RESUMEN
ABSTRACT
The project consists of the improvement of agricultural technology level in El Progreso,
with the installation of the drip irrigated as well as technical assistance for growing passion
fruit and / or pepper Paprika, in an area of 42.83 ha of the Group management Progress
belonging to the Irrigation Commission Progress benefiting 19 farmers organized.
The project presented a running operation of drip irrigation system for both cultivation and
cultivation Passion Fruit Chili Paprika. The running operation to be growing by 03
Maracuy irrigation scheduling; each of which will have peak demand in a run time of 4.95
hours and a total of 14.85 hours per day; and operating performance for the cultivation of
pepper Paprika be using 10 turns of irrigation; each of which will have peak demand in a
run time of 1.62 hours and a total of 16.20 hours per day.
The budget for the project is the sum of S /. Amounting to $ 479,474.10 $ 165,335.90 USA,
with an exchange rate of 2.90 soles, these costs include the General Sales Tax (18%).
The average cost per acre is $ 3860.28 - S /. 11194.82.
I.
INTRODUCCIN
Los trabajos y estudios realizados para la formulacin del proyecto, se han efectuado
en el mbito del Sector de la localidad de El Progreso, DISTRITO DE PATAPO,
PROVINCIA DE CHICLAYO, REGION LAMBAYEQUE.
3.2 Ubicacin del proyecto
Para efectos de la administracin y manejo del agua con fines agrcolas, tenemos que el
sector pertenece al distrito de Patapo, Junta de Usuarios Chancay- Lambayeque y a la
Comisin de Regantes El Progreso.
3.3 Vas de acceso y comunicacin
Desde la ciudad de Chiclayo, se puede acceder a la zona del proyecto, mediante la
carretera a Chongoyape con destino a la ciudad de Ptapo hasta aqu 26 Km de
recorrido (aproximadamente 35 minutos). Y a unos 03 km se ubican los predios del
GGE El Progreso, ubicados al margen de la carretera la cual se encuentra en buenas
condiciones de asfaltado.
III.
RESULTADOS Y DISCUSIN
Anlisis de Suelo
N
RESULTADO
S
pH
M1
CE
(Micromhos/c
ms)
MO (%)
1.97
Fsforo
(ppm)
Potasio
(ppm)
Calcreo (%)
3
4
5
6
7
8
9
1
0
1
1
Textura
Ao
Lo
Ar
Tipo Suelo
M
2
7.6
0
1.8
8
M
3
7.
70
2.
12
M4
1.5
7
9
1.
40
10
1.48
34
2
1.8
0
35
3
1.
95
340
46
32
22
62
15
23
65
20
15
42
35
23
Fran
co
Fo
Ar
Fo
Ao
Fran
co
7.60
1.60
367
1.90
7.50
3.40
14
2.03
Ao
Fuente. Laboratorio de Suelos y Agua INIA Ferreafe
Agua
El anlisis arroja como resultado que el agua es apta para uso agrcola, an para
cultivos exigentes como los frutales, que en este caso es una variedad mejorada. Los
resultados de los anlisis de aguas se presentan en el Cuadro N 2.
Cuadro N 02.Anlisis de Agua
RESULTADOS
pH
CE(Micromhos/cms)
Cationes(meq/lt)
Calcio (Ca)
Magnesio (Mg)
Sodio (Na)
Potasio (K)
Suma de Cationes
Aniones(meq/lt)
Carbonatos
Bicarbonatos (HCO3)
Cloruros (Cl)
Sulfatos (SO4)
Suma de aniones
RAS
CO3 Na Residual
Clase
M1
7.0
656
5.12
0.88
0.66
0.04
6.72
NE
5.60
0.85
0.22
6.67
0.40
- 0.40
C2S1
10
Biolgicos
ELEMENTO
Slidos Suspendidos (1)
pH
Slidos disueltos (1)
Manganeso (1)
Hierro Total (1)
Sulfuro de Hidrgeno (1)
Poblacin Bacterial (2)
RIESGO DE OBSTRUCCIN
MENOR
MODERADO
SEVERO
< 50
50 100
> 100
< 7.0
7.0 - 8.0
> 8.0
< 500
500 - 2,000
> 2,000
< 0.1
0.1 - 1.5
> 1.5
< 0.2
0.2 - 1.5
> 1.5
< 0.2
0.2 - 2.0
> 2.0
10,000 < 10,000
> 50,000
50,000
UNIDAD
GRADO DE RESTRICCIN
NINGUNO MODERADO SEVERO
11
CE agua
TSD
INFILTRACIN
RAS / CE agua
03
36
6 12
12 20
20 40
TOXICIDAD IONES
Sodio (Na)
Riego Superficial
Riego por Aspersin
Cloruros (Cl)
Riego Superficial
Riego por Aspersin
Boro
ELEMENTOS TRAZA
N-NO3
HCO3
PH
dS/m
mg/l
< 0.70
< 450
0.7
1.2
1.9
2.9
5.0
0.7 - 3.0
450 - 2000
0.7
0.7
0.7
2.9
5.0
0.2
0.3
0.4
1.3
2.9
> 3.0
> 2000
dS/m
>
>
>
>
>
<
<
<
<
<
0.2
0.3
0.4
0.5
0.6
me/l
me/l
< 0.7
<3
0.7 - 3.0
>3
>3
me/l
me/l
ppm
<4
<3
< 0.7
4 - 10
>3
0.7 - 3.0
> 10
me/l
me/l
Rgo.
Normal
<5
< 1.5
5 - 30
1.5 - 8.5
> 30
> 8.5
>3
6.5 - 8.4
Fuente: Gua para la Interpretacin del Agua de Riego. Ayers y Westcot, 1985. FAO.
IV.
12
A partir de este punto las aguas sern distribuidas a cada uno de los sectores de riego
por una red de tuberas de PVC principal y secundaria utilizndose dimetros de 200
mm, 160 mm, 110 mm, 90 mm, 75 mm y 63 mm; para el ingreso a la sub unidad de
riego (sectores) se ha previsto la utilizacin de los denominados arcos de riego cuya
funcin bsicamente es regular la presin y permitir o no el ingreso del agua al sector.
La unidad de bombeo ha sido seleccionada en funcin a La altura dinmica total del
sistema es ADT=44.00 m.c.a con una capacidad de 34.50 l/s, la eficiencia de trabajo de
la unidad de bombeo es 77% (eficiencia de bomba turbina 81% y eficiencia de
trasmisin de 95%), el dimetro de succin y descarga es de 8.
Cada Unidad de Riego dispondr de un sistema de conduccin y distribucin
compuesto por tramos de tubera, que van desde el cabezal hasta las vlvulas de
campo. El material utilizado ser tubera de PVC clase 5, cuyo dimetros es variable,
las mismas que irn enterradas en zanjas excavadas expresamente para ello, con
dimensiones de 50 cm de ancho, por 80 cm de profundidad.
En lo que respecta a obras civiles se construir una caseta de filtrado para proteger los
equipos de filtrado y fertirrigacin, asimismo se colocarn dados de anclaje y las
respectivas cajas de vlvulas para proteger los arcos de riego.
4.2 Criterios de Diseo
Para el presente proyecto se ha sectorizado las parcelas manteniendo la configuracin
natural de las reas de los predios con subunidades de 0,21 a 0.78 has respectivamente.
Para la Operacin del sistema de riego con el cultivo de Maracuy se han conformado
Tres (03) Turnos de Riego que vienen a representar a los 19 beneficiarios del GGE El
Progreso, los cuales operaran simultneamente entre 30 a 32 vlvula de sector y que
disponen de 4.95 horas de riego por turno y con una rea mxima por turno de 14.56
has, con un caudal mximo de operacin de 37.43 l/s (134.83 m3/hr), alcanzando un
total de 14.85 horas al da en su mxima demanda.
Para la Operacin del sistema de riego con el cultivo de Aj Paprika se han conformado
Diez (10) Turnos de Riego que vienen a representar a los 19 beneficiarios del GGE El
Progreso, los cuales operaran simultneamente entre 7, 8, 9, 10 a 12 vlvula de sector y
que disponen de 1.62 horas de riego por turno y con una rea mxima por turno de 4.47
13
has, con un caudal mximo de operacin de 34.50 l/s (124.18 m3/hr), alcanzando un
total de 16.20 horas al da en su mxima demanda.
V.
CONCLUSIONES.
con un
14
VI.
REFERENCIAS BIBLIOGRAFICAS
15