Você está na página 1de 5

1. Determine the thermal conductivity of a given material by guarded hot plate method.

SPECIFICATIONS:
1. Material: Asbestos Sheet,
2. Thickness of specimen L=2 X 12 mm (2 pieces, one at top and one at bottom),
3. Diameter of specimen (d) = 150 mm
Aim &
Formula& Observation /
Model
Result
Viva
Marks
Procedure Tabulation
Readings
Calculation
&Graph
voice
Allotted
(20)
(20)
(20)
(20)
(10)
(10)
Marks
Obtained

Total
(100)

Internal Examiner
2. Determine the thermal conductivity of given materials and plot the radial temperature
distribution of pipe insulation.
Specifications
1. Radius at which thermocouples (1-3) R1
:
28 mm
2. Radius at which thermocouples (4-6) R2
:
53 mm
3. Radius at which thermocouples (7-9) R3
:
78 mm
4. Length of the specimen, L
:
50 cm
Marks
Allotted

Aim &
Procedure
(20)

Formula&
Tabulation
(20)

Observation /
Readings
(20)

Model
Calculation
(20)

Result
&Graph
(10)

Viva
voice
(10)

Total
(100)

Marks
Obtained

Internal Examiner
3. Determine the effectiveness and efficiency of a pin-fin under natural convection mode and
draw the variation of temperature along the length of the pin- fin.
Specifications:
1.
Duct size (L x B x W)
=
150 mm x 100 mm x 150 mm
2.
Diameter of the fin d
=
12 mm
3.
Length of the fin L
=
150 mm
4.
Thermal conductivity of fin =
110 W/mK
5.
Coefficient of discharge Cd =
0.61
6.
Diameter of the orifice D
=
20 mm
Marks
Allotted

Aim &
Procedure
(20)

Formula&
Tabulation
(20)

Observation /
Readings
(20)

Marks
Obtained

Internal Examiner

Model
Calculation
(20)

Result
&Graph
(10)

Viva
voice
(10)

Total
(100)

4. Determine the effectiveness and efficiency of a pin-fin under forced convection mode and
draw the variation of temperature along the length of the pin- fin.
Specifications:
1.
Duct size (L x B x W)
=
150 mm x 100 mm x 150 mm
2. Diameter of the fin d
=
12 mm
3.
Length of the fin L
=
150 mm
4.
Thermal conductivity of fin =
110 W/mK
5.
Coefficient of discharge Cd =
0.61
6.
Diameter of the orifice D
=
20 mm
Aim &
Formula& Observation /
Model
Result
Viva
Marks
Total
Procedure Tabulation
Readings
Calculation
&Graph
voice
Allotted
(100)
(20)
(20)
(20)
(20)
(10)
(10)
Marks
Obtained

Internal Examiner
5. Determine the Stefan-Boltzmann constant using the test set up and compare with standard
value.
Specifications:
1. Mass of the disc
= 0.005 kg.
2. Dia. of the disc
= 0.020 m.
3. Material of the disc
= copper
4. Cp
= 381 J/KgK
5. Stefan Boltzmann Constant
Marks
Allotted

Aim &
Procedure
(20)

Formula&
Tabulation
(20)

Observation /
Readings
(20)

Model
Calculation
(20)

Result
&Graph
(10)

Viva
voice
(10)

Total
(100)

Marks
Obtained

Internal Examiner
6. Determine the emissivity of the given test plate (grey body) using emissivity apparatus.
Specifications:
1.
Diameter of the discs = 160 mm.
2.
Thickness of the discs = 6 mm
Marks
Allotted
Marks
Obtained

Aim &
Procedure
(20)

Formula&
Tabulation
(20)

Observation /
Readings
(20)

Model
Calculation
(20)

Result
&Graph
(10)

Viva
voice
(10)

Total
(100)

Internal Examiner
7. Determine the effectiveness and overall heat transfer coefficient for parallel and counter flow
arrangement.
Specifications:
1. Inner copper tube ID
=
9.5mm
2.Inner copper tube OD
=
12.5mm
3.Outer GI tube ID
=
28.5mm
4.Outer GI tube OD
=
32.5mm
5.Length of the heat exchanger
=
1500mm
Aim &
Formula& Observation /
Model
Result
Viva
Marks
Total
Procedure Tabulation
Readings
Calculation
&Graph
voice
Allotted
(100)
(20)
(20)
(20)
(20)
(10)
(10)
Marks
Obtained

Internal Examiner
8. Determine the convective heat transfer coefficient by forced convection.
Specifications:
1. Specimen
: Copper pipe
2. Size of the specimen : I.D. 40 mm x 400 mm long
3. Orifice diameter
: do=12.5 mm
4. G.I Pipe diameter
: dp= 40 mm
Aim &
Formula& Observation /
Model
Result
Marks
Procedure Tabulation
Readings
Calculation
&Graph
Allotted
(20)
(20)
(20)
(20)
(10)
Marks
Obtained

Viva
voice
(10)

Total
(100)

Viva
voice
(10)

Total
(100)

Internal Examiner
9. Determine the convective heat transfer coefficient by free convection.
Specifications:
1. Length of tube
= 450 mm
2. Diameter of the tube=45 mm
Aim &
Formula& Observation /
Model
Result
Marks
Procedure Tabulation
Readings
Calculation
&Graph
Allotted
(20)
(20)
(20)
(20)
(10)
Marks
Obtained

Internal Examiner

10. Conduct the performance test on two stage air compressor and draw the characteristic curves.
Specifications:
1.
Cylinder bore (LP Cylinder)
D
=
100mm
2.
Stroke length
L
=
85 mm
3.
Orifice diameter
Do
=
20 mm
4.
Speed of air compressor
N
=
750 rpm
5.
EMC
=
200 rev/kWhr
Aim &
Formula& Observation /
Model
Result
Viva
Marks
Total
Procedure Tabulation
Readings
Calculation
&Graph
voice
Allotted
(100)
(20)
(20)
(20)
(20)
(10)
(10)
Marks
Obtained

Internal Examiner
11. Conduct the performance test on the vapour compression refrigeration system to determine
(i).Theoretical COP and (ii) Actual COP.
Specifications:
1.Mass of Water =20 kg
2.Sp.heat of water = 4.187 kJ/kgK
3.Refrigerant = R12
Aim &
Formula& Observation /
Model
Result
Viva
Marks
Total
Procedure Tabulation
Readings
Calculation
&Graph
voice
Allotted
(100)
(20)
(20)
(20)
(20)
(10)
(10)
Marks
Obtained

Internal Examiner
12. Conduct the performance test on the air conditioning system to determine
(i).Theoretical COP and (ii) Actual COP.
Specifications:
1.Area of duct at outlet = 0.46 m x 0.086 m ( m2)
2.Cd =
Coefficient of discharge =
0.62
3.g
=
Gravitational acceleration = 9.81 m / s2
4.w =
Density of water
=
1000 kg / m3
5.a =
Density of air
=
1.23 kg / m3
6.t
=
Time taken for n no of revolutions
8.EMC
=
Energy meter constant =1200 rev/ kWh
Aim &
Formula& Observation /
Model
Result
Marks
Procedure Tabulation
Readings
Calculation
&Graph
Allotted
(20)
(20)
(20)
(20)
(10)
Marks
Obtained

Viva
voice
(10)

Total
(100)

Internal Examiner