1.

Determine the thermal conductivity of given materials and plot the radial temperature distribution of pipe
insulation. Specifications:
1. Radius at which thermocouples (1-3) R1
:
28 mm
2. Radius at which thermocouples (4-6) R2
:
53 mm
3. Radius at which thermocouples (7-9) R3
:
78 mm
4. Length of the specimen, L
:
50 cm
Aim &
Formula& Observation /
Model
Result
Viva
Marks
Total
Procedure Tabulation
Readings
Calculation
&Graph
voice
Allotted
(100)
(20)
(20)
(20)
(20)
(10)
(10)
Marks
Obtained
Internal Examiner
2. Determine the effectiveness and efficiency of a pin-fin under natural convection mode and draw the variation

of temperature along the length of the pin- fin. Specifications:


1.
Duct size (L x B x W)
=
150 mm x 100 mm x 150 mm
2.
Diameter of the fin d
=
12 mm
3.
Length of the fin L
=
150 mm
4.
Thermal conductivity of fin =
110 W/mK
5.
Coefficient of discharge Cd =
0.61
6.
Diameter of the orifice D
=
20 mm
Aim &
Formula& Observation /
Model
Result
Marks
Procedure Tabulation
Readings
Calculation
&Graph
Allotted
(20)
(20)
(20)
(20)
(10)
Marks
Obtained

Viva
voice
(10)

Total
(100)

Internal Examiner
3. Determine the effectiveness and efficiency of a pin-fin under forced convection mode and draw the variation of
temperature along the length of the pin- fin.
Specifications:
1.
Duct size (L x B x W)
=
150 mm x 100 mm x 150 mm
2.
Diameter of the fin d
=
12 mm
3.
Length of the fin L
=
150 mm
4.
Thermal conductivity of fin =
110 W/mK
5.
Coefficient of discharge Cd =
0.61
6.
Diameter of the orifice D
=
20 mm
Aim &
Formula& Observation /
Model
Result
Viva
Marks
Total
Procedure Tabulation
Readings
Calculation
&Graph
voice
Allotted
(100)
(20)
(20)
(20)
(20)
(10)
(10)
Marks
Obtained
Internal Examiner
4. Determine the Stefan-Boltzmann constant using the test set up and compare with standard value.

Specifications:
1. Mass of the disc
2. Dia. of the disc
3. Cp
Aim &
Marks
Procedure
Allotted
(20)
Marks
Obtained

= 0.005 kg.
= 0.020 m.
= 381 J/KgK
Formula& Observation /
Tabulation
Readings
(20)
(20)

Model
Calculation
(20)

Result
&Graph
(10)

Viva
voice
(10)

Total
(100)

Internal Examiner
5. Determine the emissivity of the given test plate (grey body) using emissivity apparatus.

Specifications: 1.Diameter of the discs


= 160 mm.
2.Thickness of the discs = 6 mm
Aim &
Formula& Observation /
Marks
Procedure Tabulation
Readings
Allotted
(20)
(20)
(20)
Marks
Obtained

Model
Calculation
(20)

Result
&Graph
(10)

Viva
voice
(10)

Total
(100)

Internal Examiner
6. Determine the effectiveness and overall heat transfer coefficient for parallel flow arrangement.

Specifications:
1. Inner copper tube ID
2.Inner copper tube OD
3.Outer GI tube ID
4.Outer GI tube OD
5.Length of the heat exchanger
Aim &
Formula&
Marks
Procedure Tabulation
Allotted
(20)
(20)
Marks
Obtained

=
9.5mm
=
12.5mm
=
28.5mm
=
32.5mm
=
1500mm
Observation /
Model
Readings
Calculation
(20)
(20)

Result
&Graph
(10)

Viva
voice
(10)

Total
(100)

Internal Examiner
7. Determine the effectiveness and overall heat transfer coefficient for counter flow arrangement.
Specifications:1. Inner copper tube ID
=
9.5mm
2.Inner copper tube OD
=
12.5mm
3.Outer GI tube ID
=
28.5mm
4.Outer GI tube OD
=
32.5mm
5.Length of the heat exchanger
=
1500mm
Aim &
Formula& Observation /
Model
Result
Viva
Marks
Total
Procedure Tabulation
Readings
Calculation
&Graph
voice
Allotted
(100)
(20)
(20)
(20)
(20)
(10)
(10)
Marks
Obtained
8. Determine the convective heat transfer coefficient by forced convection. Specifications:
1. Specimen
: Copper pipe
2. Size of the specimen : I.D. 40 mm x 400 mm long
3. Orifice diameter
: do=12.5 mm
4. G.I Pipe diameter
: dp= 40 mm
Aim &
Formula& Observation /
Model
Result
Viva
Marks
Procedure Tabulation
Readings
Calculation
&Graph
voice
Allotted
(20)
(20)
(20)
(20)
(10)
(10)
Marks
Obtained

Total
(100)

Internal Examiner
9. Determine the convective heat transfer coefficient by free convection.
Specifications:
1. Length of tube
= 450 mm
2. Diameter of the tube = 45 mm
Aim &
Formula& Observation /
Model
Marks
Procedure Tabulation
Readings
Calculation
Allotted
(20)
(20)
(20)
(20)
Marks
Obtained

Result
&Graph
(10)

Viva
voice
(10)

Total
(100)

Internal Examiner
10. Conduct the performance test on two stage air compressor and draw the characteristic curves.
Specifications: 1. Cylinder bore
(LP Cylinder)
D
=
100mm
2. Stroke length
L
=
85 mm
3. Orifice diameter
Do
=
20 mm
4. Speed of air compressor
N
=
750 rpm
5. EMC
=
200 rev/kWhr
Aim &
Formula& Observation /
Model
Result
Viva
Marks
Procedure Tabulation
Readings
Calculation
&Graph
voice
Allotted
(20)
(20)
(20)
(20)
(10)
(10)
Marks
Obtained
Internal Examiner
11. Conduct the performance test on the vapour compression refrigeration system to determine
(i).Theoretical COP and (ii) Actual COP.
Specifications:1.Mass of Water =20 kg
2.Sp.heat of water = 4.187 kJ/kgK
Aim &
Formula& Observation /
Model
Result
Viva
Marks
Procedure Tabulation
Readings
Calculation
&Graph
voice
Allotted
(20)
(20)
(20)
(20)
(10)
(10)
Marks
Obtained
12. Conduct the performance test on the air conditioning system to determine
(i).Theoretical COP and (ii) Actual COP.
Specifications:
1.Area of duct at outlet = 0.46 m x 0.086 m ( m2)
2.Cd =
Coefficient of discharge =
0.62
3.g
=
Gravitational acceleration = 9.81 m / s2
4.w =
Density of water
=
1000 kg / m3
5.a =
Density of air
=
1.23 kg / m3
6.t
=
Time taken for n no of revolutions
7.EMC=
Energy meter constant =1200 rev/ kWh
Aim &
Formula& Observation /
Model
Result
Viva
Marks
Procedure Tabulation
Readings
Calculation
&Graph
voice
Allotted
(20)
(20)
(20)
(20)
(10)
(10)
Marks
Obtained

Total
(100)

Total
(100)

Total
(100)

Internal Examiner
13. Determine the thermal conductivity of given materials and plot the radial temperature distribution of pipe
insulation. Specifications :
1. Radius at which thermocouples (1-3) R1
:
28 mm
2. Radius at which thermocouples (4-6) R2
:
53 mm
3. Radius at which thermocouples (7-9) R3
:
78 mm
4. Length of the specimen, L
:
50 cm
Aim &
Formula& Observation /
Model
Result
Viva
Marks
Total
Procedure Tabulation
Readings
Calculation
&Graph
voice
Allotted
(100)
(20)
(20)
(20)
(20)
(10)
(10)
Marks
Obtained
Internal Examiner

14. Determine the effectiveness and efficiency of a pin-fin under natural convection mode and draw the variation

of temperature along the length of the pin- fin.


Specifications:
1.
Duct size (L x B x W)
=
150 mm x 100 mm x 150 mm
2.
Diameter of the fin d
=
12 mm
3.
Length of the fin L
=
150 mm
4.
Thermal conductivity of fin =
110 W/mK
5.
Coefficient of discharge Cd =
0.61
6.
Diameter of the orifice D
=
20 mm
Aim &
Formula& Observation /
Model
Result
Marks
Procedure Tabulation
Readings
Calculation
&Graph
Allotted
(20)
(20)
(20)
(20)
(10)
Marks
Obtained

Viva
voice
(10)

Total
(100)

15. Determine the Stefan-Boltzmann constant using the test set up and compare with standard value.

Specifications:
1. Mass of the disc
= 0.005 kg.
2. Dia. of the disc
= 0.020 m.
3. Material of the disc
= copper
4. Cp
= 381 J/KgK
Aim &
Formula& Observation /
Marks
Procedure Tabulation
Readings
Allotted
(20)
(20)
(20)
Marks
Obtained

Model
Calculation
(20)

Result
&Graph
(10)

Viva
voice
(10)

Total
(100)

Internal Examiner
16. Determine the emissivity of the given test plate (grey body) using emissivity apparatus.

1.
2.

Specifications:
Diameter of the discs = 160 mm.
Thickness of the discs = 6 mm
Aim &
Formula&
Marks
Procedure Tabulation
Allotted
(20)
(20)
Marks
Obtained

Observation /
Readings
(20)

Model
Calculation
(20)

Result
&Graph
(10)

Viva
voice
(10)

Total
(100)

Internal Examiner
17. Determine the convective heat transfer coefficient by free convection.
Specifications:
1. Length of tube
= 450 mm
2. Diameter of the tube = 45 mm
Aim &
Formula& Observation /
Model
Marks
Procedure Tabulation
Readings
Calculation
Allotted
(20)
(20)
(20)
(20)
Marks
Obtained

Result
&Graph
(10)

Viva
voice
(10)

Total
(100)

Internal Examiner

18. Conduct the performance test on two stage air compressor and draw the characteristic curves.
Specifications:
1.
Cylinder bore (LP Cylinder)
D
=
100mm
2.
Stroke length
L
=
85 mm
3.
Orifice diameter
Do
=
20 mm
4.
Speed of air compressor
N
=
750 rpm
5.
EMC
=
200 rev/kWhr
Aim &
Formula& Observation /
Model
Result
Viva
Marks
Procedure Tabulation
Readings
Calculation
&Graph
voice
Allotted
(20)
(20)
(20)
(20)
(10)
(10)
Marks
Obtained
Internal Examiner
19. Conduct the performance test on the vapour compression refrigeration system to determine
(i).Theoretical COP and (ii) Actual COP.
Specifications: 1.Mass of Water =20 kg
2.Sp.heat of water = 4.187 kJ/kgK
3.Refrigerant = R12
Aim &
Formula& Observation /
Model
Result
Viva
Marks
Procedure Tabulation
Readings
Calculation
&Graph
voice
Allotted
(20)
(20)
(20)
(20)
(10)
(10)
Marks
Obtained
Internal Examiner
20. Conduct the performance test on the air conditioning system to determine
(i).Theoretical COP and (ii) Actual COP.
Specifications: 1.Area of duct at outlet = 0.46 m x 0.086 m ( m2)
2.Cd =
Coefficient of discharge =
0.62
3.g
=
Gravitational acceleration = 9.81 m / s2
4.w =
Density of water
=
1000 kg / m3
5.a =
Density of air
=
1.23 kg / m3
6.EMC=
Energy meter constant =1200 rev/ kWh
Aim &
Formula& Observation /
Model
Result
Marks
Procedure Tabulation
Readings
Calculation
&Graph
Allotted
(20)
(20)
(20)
(20)
(10)
Marks
Obtained
Internal Examiner

Viva
voice
(10)

Total
(100)

Total
(100)

Total
(100)

Você também pode gostar