ESTETIC ITALIA congratulates you for purchasing a RENEW FACE & BODY
radio frequency unit for aesthetic use.
RENEW FACE & BODY represents the most advanced application of the
latest technologies in radio frequency aesthetic use.
3 / 46
INDEX
Index
Information on use manual
Typographic conventions
The radio frequency: RENEW FACE&BODY
What is it
Where it acts and effects
General applications modalities in aesthetic
The use in aesthetic
Treatment protocol
Preparing the client
Preliminary treatment protocol
Declaration of responsibility
RENEW FACE&BODY recommended programmes
Duration and costs of treatment
Ideal use
Settings to start a treatment with RENEW FACE&BODY
Editing the settings
To start a FACE treatment
To start a BODY treatment
General information
Description of unit
Control panel
Power supply and output panel
Accessories
Unit set-up
Unpacking
Installing
Prescriptions regarding the installing environment
Maintenance
Hygienisation modality
Work place and storage
Maintenance and controls
Electric safety
Personnel training
Malfunctions
Electromagnetic interferences
Troubleshooting
Technical features
Appendixes
A - Environmental protection
B - Labels
Indications/Contraindications
Conclusions
Warranty
After-sales assistance request form
Declaration of Conformity
4 / 46
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
4
5
5
6
6
6
6
6
7
7
7
8
9
9
10
11
11
12
17
24
24
25
26
27
28
28
29
30
31
34
34
35
35
35
35
36
37
38
39
39
40
41
42
42
44
45
TYPOGRAPHIC CONVENTIONS
Certain parts of the manual are given particular emphasis by underlining.
NOTE
Notes are used to highlight particularly important information.
CAUTION
Caution messages are placed immediately before operations which, if not complied with, may lead to damages
to the unit and/or to its accessories.
! WARNING !
WARNING messages indicate operations or situations which, if ignored or not complied with, may cause
problems to the user.
5 / 46
6 / 46
TREATMENT PROTOCOL
Depending on the type of problem to be treated, the operator will choose the more suitable program,
following the table on page 9.
Preparing the client
The treatment room must have a comfortable temperature in order to avoid shivers or muscular tremors.
The client must be in as comfortable position as possible; it is recommended, like in other cases of physical
treatment, to explain to the client, prior to treatment, which sensation is to be expected.
Also ensure that you are aware and able to follow all indications relating to safety.
Estetic Italia proposes the method to rejuvenate, smooth and regenerate tissues, quickly and without
contraindications, thanks to the use of Renew Face & Body.
Before every face and body treatment, the use of the Softlight laser unit is recommended, with
programmes (1-13-16-27) for 15 minutes. This treatment allows to create a vasodilatation which favours
the microcirculation, the collagen synthesis, and notably improves the oxygenation of tissues.
It is recommended to subsequently apply the Bodyson 8 ultrasound unit with gel for 10 minutes, using the
face applicator or body plates which, thanks to the mechanical, thermal and chemical effects, prepares the
tissue causing the permeability and temperature increase of the cellular membrane, as well as the
acceleration of the tissues particles.
This pre-treatment system allows the subsequently applied radio frequency, to act deeply, completely and
in a long lasting manner
7 / 46
DECLARATION OF RESPONSIBILITY
I, the undersigned declare, under my responsibility that:
I am not pregnant
I also declare to have been informed of the indications and contraindications of the RENEW FACE&BODY
treatment
Date
SIGNATURE
8 / 46
TOTAL
DURATION
OF THE
SITTING
MINUTES
INITIAL POWER %
Deep toning
Toning
Toning
Toning
Rejuvenating
Deep rejuvenating
Invigorating
Lifting
Face
Peri-ocul. Peri-lab.
Neck
Breast cleavage
Face
Face
Face
Face
30
10
15
20
25
25
25
25
50
50
50
50
50
50
50
50
9
10
11
12
13
Toning
Toning
Toning
Toning
Toning
45
40
45
45
35
14
Toning
50
50
50
50
50
50
15
16
Toning
Rejuvenating
17
Rejuvenating
18
Lifting
Body
Stretch marks
Stomach
Buttocks
Inside thigh
Back and
surroundings
Arms
Stretch marks
Back and
surroundings
Body
NUMBER
OF THE
PROGRAM
TYPE OF TREATMENT
1
2
3
4
5
6
7
8
45
45
40
40
40
50
50
50
50
IT IS RECOMMENDED TO START THE TREATMENT WITH POWER THAT DOES NOT EXCEED 50%,
WHICH WILL THEN BE PROGRESSIVELY INCREASED ON THE BASIS OF THE TREATMENT TO BE
PERFORMED
THE POWER PERCENTAGE WILL VARY DEPENDING ON THE TYPE OF INSERT, SKIN AND AREA TO BE
TREATED.
IT IS THEREFORE RECOMMENDED TO KEEP THE APPLICATOR OR THE EARTHING PLATE AS NEAR
AS POSSIBLE TO THE AREA TO BE TREATED, SO THAT THE IDEAL TEMPERATURE IS REACHED
QUICKLY.
9 / 46
IDEAL USE
! WARNING !
Operators must make sure that the electric connections have been properly made before turning on the main
power switch
.
! WARNING !
Operators must make sure that the application plates
of the inserts/electrodes are in order before turning on the main power switch and starting a session.
After having applied the cable for connecting the adaptors to the appropriate connector, insert the power plug
into the wall socket (230 Vac) and activate the unit by switching the main ON/OFF switch on the back panel to
"ON".
This will turn on the RENEW FACE & BODY unit and the back-lit LCD will light up, meaning that the device is
ready for use.
The LCD display will light up showing the logo:
Fig.1
10 / 46
Press the encoder knob to go to the first page (Fig. 2). Here you can choose between three operating modes by
pressing the relative function key.
Fig.2
Fig. 3
Press the function key relating to the MODIFY button to toggle between the screens shown in fig. 3 and fig. 4:
11 / 46
Fig.4
Here you can choose which parameters to edit among those available (LCD brightness and contrast) for
adjusting the displays visibility to the local conditions.
Select the parameter to edit and turn the Encoder knob clockwise to increase its intensity or anticlockwise to
reduce it.
Press the function key relating to the EXIT button to return to the page shown in fig. 2.
The page also shows the version of the software currently installed on the unit.
STARTING A FACE TREATMENT
Press the function key relating ot the FACE TREATMENT button (see fig. 2), the following screen is loaded with
the indications on preparing the subject undergoing the treatment (see fig. 5):
Fig.5
.
12 / 46
Fig. 6
Fig. 7
13 / 46
Fig. 8
Once you reach the last page (see fig. 8), turning the encoder knob anticlockwise will show the information
pages in reverse order.
These pages can be used as an on-line Help and provide operators with the basic information required before
starting a treatment session, for example:
-
After following the instructions in the previous screens, press the encoder knob to set the treatment parameters.
The following screen will appear (see fig. 9):
Fig. 9
14 / 46
Press the function key relating to the MODIFY button to toggle between the screens shown in fig. 9 and fig. 10:
Fig. 10
On these screens you can set the parameters for a standard treatment, such as:
- The issued power (see fig. 9), which is set by default at 50%; operators can change the value before or
during the treatment
-
The treatment time (see fig. 10), which is set by default at 20 minutes; operators can change the value
before but not during the treatment
Once these parameters are set, press START to start the treatment.
On the screens shown in fig. 9 and fig. 10 there are two boxes that show a series of dots before you press
START: this is read-only value that cannot be edited by the operator.
Press START to start the treatment: the treatment starts as shown by the countdown (see fig. 11).
Fig. 11
The unit will periodically check the treatment temperature and will continue to work until reaching the
temperature set by the operator through the power.
15 / 46
CAUTION
When carrying out facial treatments the face applicator can only be used
with the electrodes having diameter 30 mm or 40 mm.
When the applicator comes into contact with the part being treated, a power will be detected (expressed as a
percentage) whose numeric value will replace the previously met dots.
The above-mentioned power represents the power actually absorbed by the RENEW FACE & BODY unit as
referred to the maximum power the unit is capable of supplying (equal to 100% of the power parameter).
When a treatment is under way, pressing the STOP button once will pause the unit and temporarily interrupt the
treatment.
Following which (see fig. 12):
- The operation phase field shows the message "In pause..."
- the measured field shows a series of dots instead of the temperatures numeric value, as the treatment
is currently suspended
Fig. 12
The operator can change the settings if necessary and decide whether to resume the treatment or definitively
end it.
Press START to resume the treatment: the unit will resume the treatment from the point at which it was
interrupted.
To definitively end the treatment press STOP again: the treatment will be ended and the remaining time
parameter will revert to the value shown in the Preset time parameter (see Fig. 10).
16 / 46
Fig. 13
this page contains information on how to prepare the subject for treatment.
Turn the Encoder knob clockwise to go to more windows containing information on how to proceed (see fig. 14,
15, 16, 17, 18 and 19):
17 / 46
Fig. 14
Fig. 15
18 / 46
Fig. 16
Fig. 17
19 / 46
Fig. 18
Fig. 19
Once you reach the last screen (see fig. 19), turning the encoder knob anticlockwise will show the information
screens in reverse order.
These pages can be used as an on-line Help and provide operators with the basic information required before
starting a treatment session, for example:
-
20 / 46
Fig. 20
Press the function key relating to the MODIFY button to toggle between the screens shown in fig. 20 and fig. 21:
Fig. 21
On these screens you can set the parameters for a standard treatment, such as:
-
The issued power (see fig. 20), which is set by default at 50%; operators can change the value before or
during the treatment
The treatment time (see fig. 21), which is set by default at 10 minutes; operators can change the value
before but not during the treatment
The value set as skin temperature is the temperature that will be reached on the part of the face subjected to
treatment, while the treatment time is the time for which the selected treatment is intended to last.
-
On the screens shown in fig. 20 and fig. 21 there is one boxes that show a series of dots before you press
START: this is read-only value that cannot be edited by the operator.
21 / 46
Fig. 22
The unit will periodically check the treatment temperature and will continue to work until reaching the
temperature set by the operator.
When the applicator comes into contact with the part being treated, a power will be detected (expressed as a
percentage) whose numeric value will replace the previously met dots.
The above-mentioned power represents the power actually absorbed by the RENEW FACE & BODY unit as
referred to the maximum power the unit is capable of supplying (equal to 100% of the power parameter).
When a treatment is under way, pressing the STOP button once will pause the unit and temporarily interrupt the
treatment. Following which (see fig. 23):
-
22 / 46
Fig. 23
The operator can change the settings if necessary and decide whether to resume the treatment or definitively
end it.
Press START to resume the treatment: the unit will resume the treatment from the point at which it was
interrupted.
To definitively end the treatment press STOP again: the treatment will be ended and the remaining time
parameter will revert to the value shown in the Preset time parameter (see Fig. 21).
The body part to be treated must be covered with an abundant coating of contact "GEL" (which enhances the
sound conduction of the radiant energy). The operator must distribute the radiant energy by gently massaging
the body part, i.e. by moving the radiating head over the part in order to attain an equal distribution of the energy
dose".
CAUTION
For the correct outcome of the application, it is fundamental that the subject
undergoing treatment has the earthing plate applied to an area of the body (also called
mass or reference plate) during the same treatment.
GENERAL INFORMATION
EME srl has recently developed a complete series of devices, accessories and equipment designed and built
according to the highest standards, applying the state-of-the-art technology, in full compliance with the directives
and regulations in force.
Special attention has been devoted to design, user-friendliness, functionality and safety.
The result is a compact unit, equipped with a modern line, able to offer an extremely logical operating sequence,
supported by an easy-to-read display.
The many possible aesthetic applications and the absolute safety for subjects and operators (the unit complies
with all relevant international standards) put the RENEW FACE & BODY radio frequency unit for aesthetic use at
the top of its category.
23 / 46
DESCRIPTION OF UNIT
RENEW FACE & BODY is a radio frequency unit for aesthetic use which uses, inside the body, a 470 KHz
frequency emission without causing sensory stimulation of the motor nerves or causing muscle contractions and
discomfort.
The biological effect of the heat produced by Radio Frequency waves on the skin consists in the denaturation of
collagen fibres (5 to 20% of total fibres), which cause their immediate contraction and a progressive effect lasting
for the following 4 to 6 months.
As required by Van't Hoffs principle, any reaction whose speed depends on heat is accelerated by an increase
in temperature. The increase in the metabolism depends directly on the increase in heat.
The increased metabolism causes an increase in the demand for oxygen and nutrients and the production of
catabolites and metabolites.
The heating of the body parts subjected to treatment produces various results:
-
The unit for RENEW FACE & BODY radio frequency for aesthetic use
The RENEW FACE & BODY radio frequency unit for aesthetic use is equipped with a control panel optimized for
its specific field of application and for the functions for which the unit is intended.
All operation parameters are controlled in real time by a sophisticated electronic microprocessor circuit and the
functions are clearly shown on a backlit LCD display and indicated by specific sound signals.
24 / 46
CONTROL PANEL
Figure 1 shows the front panel with its controls and indications and their relative meanings.
Fig. 1 : Front control panel
Meanings:
1.
2.
3.
4.
5.
6.
7.
Name of unit
LCD Graphic Display
Left side function buttons
Right side function buttons
Output START button
STOP / PAUSE button
Encoder knob for: selecting / confirming button
Buttons 3) and 4) have the function that is shown on the display at any given time.
25 / 46
Meanings:
1. Double-pole main ON/OFF switch
2. Fuse box
3. Three-pole (male) socket for network power cable
4. Ground terminal
Fig. 3 : Output panel
CAUTION
The connections between the applicators
and their respective connectors are
compulsory: one applicator will not fit into
the others connector and vice versa.
Meanings:
5. Output connector hole
face applicator/body applicator
6. Output connector hole
earthing applicator/metal plate
26 / 46
1
1
1
1
1
1
1
1
1
1
All the above accessories make up a kit for radio frequency units.
The body applicator can be fitted with any of the inserts/electrodes supplied for body treatments.
The face applicator can be fitted with the following supplied inserts/electrodes:
27 / 46
UNIT SET-UP
UNPACKING
The RENEW FACE & BODY radio frequency unit for aesthetic use comes packed in a box filled with packing
filler and designed for easy storage and safe transportation.
To unpack the unit, put the box on a flat, solid surface and remove the polystyrene top.
Carefully take out the unit.
The unit and its accessories are wrapped in protective sheets of transparent polyethylene. The packing also
contains:
Use Manual;
n. 1 cable for network power supply;
n. 2 spare fuses (see technical features).
INSTALLING
28 / 46
! WARNING !
RENEW FACE & BODY UNIT IS GUARANTEED TO WORK CORRECTLY,
RESPECTING THE INSTALLATION AND USE INSTRUCTIONS INDICATED,
ONLY WITH THE USE OF ORIGINAL ACCESSORIES AND SPARE PARTS.
In case of problems or difficulties during installation
contact EME srl Customer Service.
CAUTION
Do not use accessories other than the ones provided: they might damage
the unit, causing the warranty to become void.
The back of the unit is fitted with an integrated module for network power supply, consisting of a three-pole
connector for the power cable, a removable fuse box with two fuses (see technical features) and a double-pole
main switch.
Connect the power cables three-pole female plug into the integrated module and make sure it is perfectly inside
the connector.
! WARNING !
Before connecting the cable to the network plug, make sure the unit has not been
damaged during transport and ensure the electric energy supply features
on the available current socket, satisfy the data on the plate, reported at the back of the unit.
! WARNING !
The electricity powering the unit is VERY DANGEROUS.
Be sure the power cable is disconnected from the mains
before you connect or disconnect it from the connector on the unit.
! WARNING !
29 / 46
! WARNING !
For safety reasons, the power cable is supplied with a plug with protective earthing.
Use only adequately grounded power sockets.
The unit must be connected only to power systems complying with safety regulations.
If any extensions are necessary, make sure they are provided with an efficient earthing protection conductor.
Failure to observe this recommendation may lead to the accidental electrocution
of persons and affect the units operation.
CAUTION
If an extension is used between the RENEW FACE & BODY unit and other units,
check that the total current absorption of the connected units does not exceed the
maximum current allowed for that type of cable or however not higher than 15A.
! WARNING !
This unit is not suitable for use with flammable liquids
with air and oxygen or with nitrogen protoxide, do not install in such rooms.
! WARNING !
Avoid installing and/or leaving the unit near sources of heat,
exposed to rain, humidity, or where it might get wet.
For the safety of the client and the operator, the following obligations must be respected:
30 / 46
MAINTENANCE
The RENEW FACE & BODY radio frequency unit for aesthetic use does not require special maintenance. Clean
the applicators regularly to ensure ideal operation and safety.
! WARNING !
For safety reasons
before servicing or cleaning the unit,
YOU MUST
turn off the rear main switch
and disconnect the power cable from the mains.
To clean the outside of the unit only use a soft cloth dampened in hot water, or a non-flammable, non-abrasive
liquid cleaning agent.
Clean the front control panel in the same way.
The applicators, and especially the treatment head, should be regularly cleaned using water and denaturised
alcohol.
31 / 46
! WARNING !
Operators should be informed about the need to carry out periodic maintenance on the applicators. In particular:
- inspect the treatment head for any cracks that might let in the conducting fluid;
- make sure the applicators cables and connectors are in good conditions.
CAUTION
The applicators may be opened and/or disassembled only by personnel authorized by EME srl
:
tampering will cause the immediate voiding of all warranty rights,
as well as damaging the applicator.
CAUTION
Do not use thinners, detergents, acid solutions, aggressive solutions or flammable liquids
to clean the external parts of the unit and accessories.
Using these substances, or misusing the accessories,
will cause the immediate voiding of all warranty rights
, as well as irreparably damaging the unit and the electrodes.
Do not spray or pour liquids on the external casing of the RENEW FACE & BODY radio frequency units for
aesthetic use, nor on the air vents.
Do not dip the unit in water.
Do not dip the applicators or cables in liquid solutions: their immersion in such solutions will cause the
deterioration of the electronic components and comprise the insulation of the electric cables.
After cleaning the outside of the box, perfectly dry all parts before starting the unit again.
Do not under any circumstances disassemble the unit in order to clean it or inspect it: there are no parts that
need cleaning inside the unit, and at any rate RENEW FACE & BODY radio frequency units for aesthetic use
may be opened only by specialized personnel authorized by EME srl.
32 / 46
check that the power supply cable is intact and connected to the electric network,
visually examine the whole unit for any damages.
Check there is no humidity near the device, particularly on the connectors.
At the end of the treatment, switch off the unit and disconnect the power supply cable if the unit is not to be
used immediately.
! WARNING !
Should there be damages on the cable, replace it before start up
of unit with one the same as that provided.
The RENEW FACE&BODY system correctly installed, in good maintenance state and used according to
regulations, does not present dangers, neither for operator nor for the client during his therapeutic work.
Before using such system check the network voltage is 230 V, 50 Hz.
Avoid placing objects on the unit.
Avoid installing or leaving the system near sources of heat, or exposed to rain or humidity
If any object should penetrate inside or liquid be poured on, immediately disconnect the unit from the network
and have the specialised personnel check it, before using it again.
Clean the external casing with a soft cloth, eventually slightly damp (not dripping) with water and neutral
detergent or alcohol or products for furniture; do not use abrasive products or solvents.
Do not, for any reason, open or disassemble the unit.
Periodically check the state of the cable and plug, in case of wear, replace them.
Some verifications can be made by the personnel operating on the device, whereas others, more technical, must
be carried out by trained personnel and authorised in writing by the manufacturer.
To guarantee the safety and the correct functioning of the unit, respect the following maintenance program.
33 / 46
ACTION
COMPANY
Operator
Operator
CADENCE
Daily
every session with different client
Operator
Weekly
Operator
Weekly
! WARNING !
RENEW FACE&BODY is an electronic device, therefore to guarantee its safety
the periodic maintenance will have to be carried out exclusively at the manufacturer
laboratory or by adequately trained personnel, and authorised in writing by the manufacturer.
Hygienisation mode
The device must be hygienised periodically. Disconnect the power supply plug from the socket.
Do not use compressed air or nebulising products; any dripping of any liquid can compromise the units
functioning.
In case of accidental liquid or foreign materials infiltration inside the casing, do not attempt to open the device to
remove the penetrating material, but contact the technical assistance service and do not use the unit.
Cleaning must be carried out using non abrasive materials dampened with non corrosive hygieniser products.
34 / 46
The installation, the set up, periodical checks or repairs are carried out by the manufacturer or personnel
authorised by him;
The electric plant is in compliance with the safety regulations;
The unit is used according to the use manual (keep the manual in a safe place);
The unit is used with the accessories supplied by the manufacturer.
Electric Safety
According to the current C.E.I. 62.5 standards, the safety, the reliability and the performance of the system can
be guaranteed only if:
Assembly, set up or repairs are carried out by the manufacturer or persons by him authorised.
The electric plant of the room in which it is installed, is in compliance with the respective regulations.
The unit is used in compliance with the use instructions.
Measuring of the dispersion currents and resistance of the protection conductor and checking the integrity of the
part connected to the network, is to be carried out every two years, according to the C.E.I. n.12764 dated
November 1989 publication.
PERSONNEL TRAINING
The RENEW FACE & BODY unit should be used only by operators who have been professionally trained to
carry out perfectly safe treatments.
MALFUNCTIONS
The RENEW FACE & BODY radio frequency units for aesthetic use have been designed and built applying
advanced technology and high-quality components in order to ensure efficient and reliable continuous use.
However, if any malfunction should occur, we recommend consulting the following guide before contacting an
authorized service centre.
CAUTION
Only trained personnel can access the internal parts of the unit
authorised by the manufacturer.
For repairs or information please contact EME srl
or an authorized service centre.
35 / 46
! WARNING !
DO NOT OPEN THE RENEW FACE & BODY unit: the inside contains
HIGH VOLTAGE ELECTRICITY which can be DANGEROUS.
Should any of the following events occur, disconnect the unit from the mains and contact EME srl customer
service:
the cable or the integrated rear power supply module are damaged or show signs of wear;
a liquid has penetrated inside the unit;
the unit was left in the rain.
ELECTROMAGNETIC INTERFERENCE
The RENEW FACE & BODY radio frequency units for aesthetic use have been designed and built in compliance
with European Directive 89/336/EEC on ELECTROMAGNETIC COMPATIBILITY with the purpose of providing a
reasonable degree of protection against harmful interferences in homes or health centres. The EC marking on
the unit guarantees the units conformity to the Directive.
All the necessary tests and measures were carried out in EMEs Internal Lab for Tests, Measures and Trials
(LPMC) and at specialized external centres. Upon request, customers have been allowed to view the EMC test
reports on the companys premises.
On the grounds of their operating principle, RENEW FACE & BODY radio frequency units for aesthetic use
produce an acceptable amount of radio frequency energy and have an adequate degree of immunity from
radiating electromagnetic fields: In these conditions, no interferences can occur that are damaging for radioelectric communications, electromedical equipment used for monitoring, diagnostics, treatments and surgery,
office equipment such as computers, printers, photocopiers, fax machines, etc., and for any other electric or
electronic device used in those places, provided they comply with the EMC Directive on ELECTROMAGNETIC
COMPATIBILITY.
However, in order to prevent any possible interferences, radio frequency units should be used at a safe distance
from critical life-monitoring devices and treatments carried out on subjects carrying pacemakers should be
performed with caution.
36 / 46
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
Plug not completely inserted in power
socket.
SOLUTION
37 / 46
TECHNICAL SPECIFICATIONS
250 VA
230 Vac
1.6A Ret. - 5 x 20 mm
115 Vac
3.15A Ret. - 5 x 20 mm
Hazard class
up to 30 minutes
Temperature
(3445)C 1C
Output channels
39x30x92h cm
Unit weight
32 Kg
* on request
38 / 46
This symbol means that the product should not be disposed of as household waste.
When the time comes to discard the units, users should hand them over to collection centres for the recycling of
electric and electronic equipment.
39 / 46
Appendix B
LABELS
Nameplate
(on back of unit)
40 / 46
INDICATIONS
The RENEW FACE & BODY radio frequency unit for aesthetic use is applied on the following imperfections:
CONTRAINDICATIONS
pregnancy
Holders of pacemakers
sclerodermia
moles
mycete
CONCLUSIONS
As with every treatment, mechanical or manual, the responsibility of eventual consequences on the subject
being treated is of the operator, who must be properly trained on the use of the ESTETIC ITALIA units.
The Company is lifted from any responsibility, in case of consequences and/or erroneous applications of
the units, on the treated subject.
In case of need, we invite the user to contact an ESTETIC ITALIA authorised dealer.
41 / 46
WARRANTY
EME srl guarantees the quality of its units for a period of 24 months from the date of purchase, provided they are
used in accordance with the instructions contained in this manual.
During the warranty period, any faulty products will be repaired or replaced by the manufacturer at its own
discretion.
Units will not be replaced under any circumstances.
The warranty does not cover malfunctions or damages caused by:
disconnect the power cables and the cables connecting the applicators, etc.;
carefully clean and disinfect all the parts and accessories that have been in contact with the subject.
For obvious sanitary reasons protecting the health of technical personnel (Directive concerning health in the
workplace, Law no. 626 dated 19 Sept.1994), any devices considered hygienically unsafe will not be
examined by the acceptance staff;
42 / 46
COMPANY
PRODUCT
CONTACT PERSON
TEL
FAX
SERIAL
NUMBER
PURCHAS
E DATE
ENCOUNTERED FAULT
APPROV.
Necessary condition for the sending of the goods is the sending of the present FORM completely filled in, to be attached to the
shipment, possibly together with a detailed TECHNICAL REPORT.
If not, we will not be able to solve the problem.
Requested date
_______________________________________
____________
43 / 46
DECLARATION OF CONFORMITY
The manufacturer
EME s.r.l. via degli Abeti 88 / 1
61100 Pesaro (PU) ITALY
DECLARES UNDER ITS OWN RESPONSIBILITY THAT THE PRODUCT:
Unit for radio frequency treatments models:
IEC 62-50
EN 55011 group 2
class A (IEC 110.6)
EN 61000 4 1
EN 61000 4 2
EN 61000 4 3
EN 61000 4 4
IT IS ALSO DECLARED THAT THIS UNIT IS NOT DESTINED FOR MEDICAL USE, IS CLASS I AND IS
DENOMINATED "ELECTRIC UNIT FOR AESTHETIC USE" (62/39- 10/1992)