Escolar Documentos
Profissional Documentos
Cultura Documentos
00136
1. Introduction
The design criteria to obtain satisfactory seismic performance of steel moment resisting frame (MRF) buildings is a major research issue which has been deeply
discussed during recent years (e.g. Luco and Cornell [2000], Yun et al. [2002],
among others). Building damage survey carried out in the aftermath of the 1994
457
458
00136
00136
459
The framework employed within this study is based upon the comparison of
the seismic performance of perimeter and spatial MRFs, which are consistently
designed. Thus, the set of low- (three-storey) and medium-rise (nine-storey)
perimeter frames designed within the SAC Steel Project for the Los Angeles, Seattle
and Boston seismic zones was considered as a benchmark. The scheme of the study
carried out can be summarised as follows:
Definition of the design parameters for steel MRF systems. A critical assessment
of MRF design procedures and approaches is carried out in order to establish the
structural parameters governing the seismic design.
Elastic analyses (static and multi-modal) of the SAC perimeter frame buildings
under design load distributions and evaluation of major design parameters.
Consistent design of spatial frame systems, as alternative structural configuration
for the SAC model buildings. The design is consistent because it is carried out
with two specific objectives: (i) obtaining the same period as the perimeter frame
building, i.e. same lateral stiffness under design horizontal loads; (ii) supplying
the same yield strength as perimeter frame building. It is also worth mentioning
that the total weight of both configurations does not differ significantly.
Assessment of the inelastic behaviour of perimeter and spatial frames and
comparisons.
Evaluation of the seismic performance and inelastic demands under severe
earthquakes of perimeter and spatial frames and comparisons.
The seismic behaviour of perimeter and spatial configuration structures was
evaluated by means of push-over non-linear static analyses and inelastic dynamic
analyses. Comparisons between analysis results were developed in a well defined
framework. A clear scheme to define and evaluate relevant limit states (LSs) is
suggested in agreement with a similar proposal available in the literature [Broderick
and Elnashai, 1996; Elnashai et al., 1998]. Thus, the failure modes, either local or
global, were computed and correlated to design choices, particularly concerning
strength requirements (column overstrength factors) and stiffness (elastic stability
indexes). Moreover, the inelastic response exhibited by perimeter and spatial MRFs
under severe ground motions was assessed. Conclusions are drawn in terms of local
and global performance, namely (i) global and inter-storey drifts, (ii) beam and
column plastic rotations and (iii) hysteretic energy.
3. Structural Systems
3.1. Description
The assessed structures are three- and nine-storey office buildings, designed
according to the UBC 1994 provisions for three different seismic zones, respectively
Los Angeles (LA), seismic zone 4, Seattle (SE), seismic zone 3 and Boston (BO),
seismic zone 2A. They were designed by three U.S. professional firms, i.e. Brandow
460
00136
00136
Fig. 1.
Geometry of three-storey MRFs: plan layout (left) and vertical section (right).
461
462
00136
Fig. 2.
Geometry of nine-storey MRFs: plan layout (left) and vertical section (right).
Beams
Frame
Storey
SE
BO
LA
SE
External Columns
BO
LA
SE
BO
01
12
23
W33 118
W30 116
W24 68
W24 76
W24 84
W18 40
W21 62
W21 57
W18 35
W14 311
W14 311
W14 311
W14 176
W14 176
W14 176
W14 99
W14 99
W14 99
W14 257
W14 257
W14 257
W14 159
W14 159
W14 159
W14 74
W14 74
W14 74
01
12
23
34
45
56
67
78
89
910
W36 160
W36 160
W36 160
W36 135
W36 135
W36 135
W36 135
W30 99
W27 84
W24 68
W30 108
W30 108
W30 116
W30 108
W27 94
W27 94
W24 76
W24 76
W24 62
W24 62
W24 68
W36 135
W33 118
W30 116
W30 116
W30 108
W30 99
W27 94
W24 76
W18 40
W14 500
W14 500
W14 455
W14 455
W14 370
W14 370
W14 283
W14 283
W14 257
W14 257
W24 229
W24 229
W24 229
W24 229
W24 207
W24 207
W24 162
W24 162
W24 131
W24 131
W14 233
W14 233
W14 233
W14 233
W14 211
W14 211
W14 176
W14 176
W14 120
W14 120
W14 370
W14 370
W14 370
W14 370
W14 283
W14 283
W14 257
W14 257
W14 233
W14 233
W24 229
W24 229
W24 229
W24 229
W24 207
W24 207
W24 162
W24 162
W24 131
W24 131
W14 159
W14 159
W14 159
W14 159
W14 132
W14 132
W14 99
W14 99
W14 68
W14 68
00136
Nine-Storey
LA
Internal Columns
Three-Storey
Beam and column cross sections (three- and nine-storey perimeter MRFs).
Table 1.
463
464
00136
3.2. Modelling
The structural analysis was performed through two finite element method codes.
Elastic analyses were carried out by means of SAP2000 [SAP2000, 1999], while
the computer code DRAIN-2DX [Prakash et al., 1993] was used to evaluate the
responses of both perimeter and spatial MRFs beyond the elastic limit (inelastic
static and non linear dynamic analyses). Moreover, DRAIN-2DX models were calibrated on the basis of the SAP2000 counterparts. Bare frames, employing centreline
dimensions, were modelled as two-dimensional assemblages of plastic hinge (lumped
plasticity) beam and beam-column elements. The latter account for bending-axial
interaction, through a linearised biaxial plastic domain (bending moment-axial
load), characterised by horizontal and vertical straight lines corresponding to 10% of
adimensionalised bending and axial capacity, with reference to full plastic bending
moment and squash load, respectively. Bilinear elastic plastic behaviour with strain
hardening of 1% was adopted to model plastic hinges. Shear behaviour of beams and
columns was assumed to remain linearly elastic. Geometric non-linearities, i.e. P
effects, were included within elastic and inelastic analyses. Panel zone yielding and
deformation were not considered. Moreover, the additional stiffness and strength
due to the presence of the concrete deck slab were not accounted for in the analysed
plane systems. Dynamic elastic analyses were based upon a 5% equivalent viscous
damping, whilst the latter was not accounted for in the inelastic analyses since
dissipative sources other than material plasticity were not considered.
(1)
1.25ZIS
2
Rw T 3
(2)
00136
465
during recent years [Chopra and Goel, 2000]. However, it is common among professionals to adopt empirical formulas like that proposed by UBC (Method A):
3
TA = Ct (Htot ) 4
(3)
(with Ct = 0.035 for steel frames and Htot is the global height in feet), albeit
the code specifically advises the adoption of a more refined, Rayleigh type formula
(Method B ). In such case, as an upper limit of the period to be used in the assessment of structural deformations, the code requires, for high seismicity areas
(Zone 4):
TB,max = 1.30 TA ,
(4)
TB,max = 1.40 TA
(5)
Method A
Method B
Wind Loads
Dynamic Analysis
V /W
[%]
d/h
[%]
Dtop /H
[%]
T
[sec]
V /W
[%]
d/h
[%]
Dtop /H
[%]
V /W
[%]
d/h
[%]
Dtop /H
[%]
T
[sec]
Dtop /H
[%]
LA-3P
SE-3P
BO-3P
0.55
7.64
5.73
2.87
0.30
0.38
0.35
0.26
0.33
0.30
0.72
0.77
0.77
6.26
4.48
2.24
0.25
0.30
0.29
0.22
0.26
0.24
2.36
3.08
3.08
0.07
0.15
0.27
0.06
0.13
0.23
0.99
1.31
1.76
0.14
0.09
0.09
LA-9P
SE-9P
BO-9P
1.38
4.04
3.04
1.51
0.30
0.41
0.28
0.28
0.36
0.21
1.79
1.93
1.93
3.39
2.42
1.21
0.25
0.33
0.22
0.24
0.29
0.18
2.53
3.32
3.32
0.18
0.35
0.59
0.13
0.27
0.32
2.53
3.30
3.63
0.12
0.10
0.10
00136
T
[sec]
Frame
Fundamental period, base shear, maximum drift index and roof drift (three- and nine-storey perimeter MRFs).
466
Table 2.
00136
467
stringent than strength. For code compliant design [UBC, 1994] the inter-storey
drift limitation is equal to either 1/300 or 1/400 for structures with fundamental period respectively either lower or higher than 0.7 sec. Thus, for three-storey
buildings, 1/300 applies when Method A is used, since Eq. (3) provides a period
value equal to 0.55 sec; on the other hand, 1/400 applies if Method B or spectrum
analysis are adopted.
Inter-storey drift ratios computed for low-rise frames show that code limits
are exactly fulfilled only in LA-3P, while they are slightly exceeded in SE-3P and
BO-3P. However, for such buildings, the roof drift is respectively less than 1/300
and 1/400 under Methods A and B design loads. Roof drift values obtained through
response spectrum analyses are even smaller than the latter ones.
It should be pointed out that for the BO-3P building the base shear due to wind
actions is larger than the seismic shear. Nevertheless, the maximum deformations
occur under the seismic force distribution, due to a larger overturning moment.
Thus, it is likely that member proportioning was governed by the seismic load
condition.
With regard to the medium-rise buildings, the design load due to wind actions
is higher than the seismic ones for BO-9P and SE-9P. It is interesting to note
that whereas for BO-9P the effects due to wind actions (d/h and Dtop /H) are
also greater than the seismic loads, for the SE-9P building the roof and inter-storey
drifts induced by wind actions are slightly smaller than those induced by earthquake
loading.
The LA-9P building fully satisfies the drift limitation (1/400) under Method B
design loads, while SE-9P and BO-9P slightly exceed it. However, the nine-storey
buildings spectrum analysis provides values of the deformation parameters which
are also by and large within code limitations.
Concerning stiffness distribution, the structures exhibit a quite smooth variation
of global stiffness over the height. In the low-rise frames while the beam cross
sections are reduced over the frame height (with the exception of the SE-3P frame,
which has second floor beams stiffer than first storey ones), the columns cross
sections are the same. In the medium-rise frames both columns and beams are
varied throughout the building height. Column splices are generally located at every
third storey, and beams are consistently reduced. In SE-9P, as for SE-3P, second
floor beams are stiffer than first storey ones.
4.3. Design stress level and yield strength
The stress level in structural members under gravity and seismic lateral loads
(Methods A and B of UBC) was evaluated and very low stress values were obtained.
Thus, the base shear Vy corresponding to first yield, i.e. onset of yield strength
in the most stressed section, was evaluated. Values of Vy , normalised to seismic
weight W and to the seismic base shears (VUBC-A and VUBC-B ), are provided for
three- and nine-storey buildings in Table 3; the values for wind actions are also
VUBC-M.A /W
[%]
VUBC-M.B /W
[%]
VWIND /W
[%]
Vy -triang. /W
[%]
Vy -unif. /W
[%]
Vy -triang. /
VUBC-M.A
Vy -triang. /
VUBC-M.B
Vy -unif. /
VWIND
LA-3P
SE-3P
BO-3P
7.64
5.73
2.87
6.26
4.48
2.24
2.36
3.08
3.08
20.1
18.59
10.89
22.79
21.02
11.25
2.63
3.24
3.79
3.23
4.15
4.86
9.66
6.82
3.65
LA-9P
SE-9P
BO-9P
4.04
3.04
1.51
3.39
2.42
1.21
2.53
3.32
3.32
10.18
8.06
7.53
10.61
8.43
7.79
2.52
2.65
4.99
3.00
3.33
6.22
4.19
2.54
2.35
00136
Frame
468
Table 3.
00136
469
included. Design over-strength factors, herein defined as the ratio Vy /VUBC , are
high. They range between 2.52 and 3.25, except where the design was governed by
wind (BO frames). These large values are due to several features: (i) the ratio of
yield-to-allowable stress (about 1.5), (ii) the compliance to drift limitations, (iii)
the compliance of SCWB requirement and (iv) the different susceptibility to second
order effects. The latter is significant for BO MRFs whose Vy /VUBC represent an
outlier when compared to the mean values.
It is worth mentioning that the design of BO-3P as well as SE-9P and
BO-9P, which exhibit over-strengths equal to 3.80, 2.65 and 4.97, respectively, were
governed by wind loading. Thus, the computed Vy /VUBC factors do not refer to the
actual design condition.
Finally, it is interesting to note that for BO frames (both low- and mediumrise), as well as for SE medium-rise frames, the over-strength factors due to the
wind are lower than the seismic counterparts. By contrast, LA frames (three- and
nine-storeys) and SE low-rise frame, exhibit design over-strength for wind greater
than for earthquake loads.
4.4. Column over-strength factor
Column over-strength factors (COF s) were computed at each frame joint using the
following standardised relationship [UBC, 1994]:
COF =
Zc (fyc fa )
Zb fyb
(6)
in order to verify the fulfilment of the strong column weak beam (SCWB) requirement (COF 1). In the above equation Zc , Zb and fyc , fyb are section plastic
modulus and yield stress respectively for columns and beams framing into the joint,
while fa is the axial stress in column members. An adequate column over-strength
factor gives rise to a configuration where columns are protected from plastic hinge
formation. Hence, inelastic deformations should occur in beams.
It is worth mentioning that COF s in three-storey frames (Table 4) are greater
than unity, minimum values being 1.06, 1.23 and 1.94, respectively, for BO-3P,
Table 4. COF s (three- and nine-storey
perimeter MRFs).
Frame
Minimum
Maximum
LA-3P
SE-3P
BO-P
1.94 (1)
1.23 (2)
1.06 (1)
3.77 (3)
3.60 (3)
1.87 (2)
LA-9P
SE-9P
BO-9P
1.39 (7)
1.17 (9)
0.68 (2)
4.89 (8)
3.66 (1)
2.04 (1)
470
00136
SE-3P and LA-3P buildings. Moreover, for BO-3P nearly 80% of the total number
of beam-to-column connections exhibit COF s between 1.0 and 1.50, thus showing high risk of extensive column hinging. Indeed, recent studies [Nakashima and
Sawaizumi, 2000] showed that plastic hinges in columns cannot be prevented by
simply satisfying the requirement COF 1. Minimum COF values strongly depend on ground motions and importance of higher vibration modes of vibration. As
rule of thumb, COF s ranging from 1.5 to 2 are required to ensure elastic response of
column members. As a consequence, for low-rise buildings, the adequate fulfilment
of SCWB can be predicted only for LA-3P.
Values of COF vary quite significantly for medium-rise buildings (Table 4) as
a function of seismic hazard. Indeed, for LA-9P, values ranging from 1.4 to 1.9
occur between the fourth and sixth floor, while values greater than 2 can be found
elsewhere. In BO-9P building, COF values smaller than 1 characterise all beam-tocolumn joints from the third to seventh floor. Values equal to unity (eighth floor)
or greater can be found in the remaining floors. An intermediate situation can be
observed for SE-9P, exhibiting COF between 1.4 and 1.6 (first and third floor) or
1.7 and 2.1 (fourth and seventh floor); values greater than 2 are located at the
eighth floor. Thus, for LA-9P a SCWB behaviour is expected, while for BO-9P a
weak column strong beam (WCSB) behaviour at intermediate storeys, with column plastic hinges, seems to be unavoidable. Finally, in SE-9P, plastic hinges are
expected mainly in beam members, although some column plastic deformations are
likely to occur.
4.5. Stability
The design criteria for MRFs are based also on specific checks for second order effects at each storey and overall stability. P effects can be approximately
evaluated through the stability index () expressed as follows:
=
Ptot dr
,
Vtot h
(7)
where Ptot is the total gravity storey load, Vtot the total seismic storey design shear,
whilst dr and h are, respectively, the design inter-storey drift and relative height.
The stability index expressed by Eq. (7) may be assumed approximately equivalent, for framed structures, to the elastic critical vertical load ratio [Horne, 1975],
defined as the ratio (P/Pcr ) in which P is the total vertical load and Pcr is the
elastic critical load value for failure in a sway mode. Therefore, it represents a
measure of the sensitivity to P effects. In International Standards [UBC, 1994;
1997; EC8, 1998], it is required that the ratio should not to exceed 0.10 in order
to neglect P effects. On the other hand, if 0.10 < 0.30, then P effects
should be accounted for; the upper bound for is, however, assumed equal to 0.30.
The -value was computed for all floors in low- and medium-rise frames, under
seismic actions. The maximum values, along with the storey level where they are
00136
471
Wind
Frame
Minimum
Maximum
Minimum
Maximum
LA-3P
SE-3P
BO-P
0.017 (3)
0.029 (3)
0.049 (3)
0.026 (2)
0.043 (2)
0.039 (2)
0.021 (3)
0.038 (3)
0.064 (3)
0.026 (2)
0.044 (2)
0.080 (2)
LA-9P
SE-9P
BO-9P
0.022 (9)
0.030 (9)
0.049 (9)
0.065 (1)
0.096 (1)
0.154 (1)
0.046 (7)
0.057 (9)
0.069 (7)
0.065 (1)
0.097 (2)
0.146 (1)
found, were also evaluated (Table 5). The values corresponding to wind effects were
included for comparative purposes.
For low-rise MRFs, the stability check is greatest at the second floor, independently of seismic region. The maximum values for are always lower than 0.10, with
the highest value for BO-3P frame (max = 0.080), whilst the greatest safety margin
for stability checks is exhibited by LA-3P (max = 0.026). Intermediate behaviour
characterises the SE-3P building (max = 0.044).
For nine-storey buildings the variation of stability index heightwise is more
pronounced than in low-rise frames, with the highest values are at either the
first or second floor, and a nearly linear reduction from the base to roof level.
The most critical stability indexes were found for the BO-9P building (max =
0.154), whilst greater safety margin for stability checks is exhibited by LA-9P frame
(max = 0.065). An intermediate behaviour characterises the SE-9P frame (max =
0.097).
As a result, second-order effects can be significant for BO-9P and, to a lesser
extent, SE-9P. These frames possess the highest values of the stability index; similar
results were found for BO-9S and SE-9S. However, the latter are characterised by
lower values than the perimeter frames, thus rendering the onset of instability
more unlikely.
472
00136
it is Wtot = 90 140 kN, thus for spatial MRF is: WMRF-S = 15023 kN versus
WMRF-P = 45 070 kN for the perimeter MRF.
The design of buildings with spatial frames was carried out according to UBC
seismic provisions [UBC, 1994]. The design target was to match the stiffness
and strength properties of their perimeter counterparts. Member cross sections
employed are provided in Table 6.
The results of comparative analyses for the design parameters of both spatial
and perimeter frames are discussed hereafter.
5.1. Period and design forces
The fundamental periods of low- and medium-rise spatial frames are provided in
Table 7. The values computed by means of code equations are equal to perimeter
values because the building height does not change. Similarly, for the design base
shears, which are based on the spectral ordinates.
Negligible variations of the fundamental period were found for low-to-moderate
seismic zone (BO and SE). Spatial frames are slightly stiffer than perimeter frames;
however, variations do not exceed 8%. Similarly, medium-rise frames show roughly
the same periods for either perimeter or spatial configurations.
Finally, modal masses relative to the first vibration mode were computed for the
assessed buildings; such values were then compared. Two points are worth noting:
(i) all frames possess a modal mass nearly equal to 85% and (ii) modal masses of
perimeter structures are roughly equal to spatial ones; the variations are, in fact,
within 3%. As a result, a dynamic response correspondent to a single degree of
freedom system (SDOF) may be predicted for the set of frames, either three- or
nine-storeys.
5.2. Lateral stiffness
Table 7 provides maximum values of elastic deformation parameters (inter-storey
and roof drift ratios) under design loads for low- and medium-rise spatial structures.
Values relative to low-rise frames are compliant with code limitations, for either
Method A (d/h 1/300) or Method B (d/h 1/400). This is not the case for SE3S; however, the exceedence is around about 5% and hence is negligible. By contrast,
the spatial nine-storey frame design gave rise to structures (LA-9S and BO-9S)
exceeding slightly standardised values, namely 1/400; higher d/h were found for SE9P. Maximum inter-storey drifts are not found at the same floor, being the second
for BO-9S and fourth for LA-9S. Drift ratios computed for spatial configurations
replicate the response established for perimeter frames.
5.3. Design stress level and yield strength
Base shears Vy corresponding to first yield, normalised to seismic weight (W),
i.e. Vy /W , and to seismic base shears (VUBC-A and VUBC-B ), are given in Table 8
Beam and column cross sections (three- and nine-storey spatial MRFs).
Beams
Frame
Storey
LA
SE
BO
LA
SE
BO
LA
SE
BO
01
12
23
W18 71
W18 65
W18 55
W14 48
W14 48
W14 26
W14 26
W14 26
W14 22
W14 120
W14 120
W14 120
W14 99
W14 99
W14 99
W14 61
W14 61
W14 61
W14 120
W14 120
W14 120
W14 99
W14 99
W14 99
W14 61
W14 61
W14 61
01
12
23
34
45
56
67
78
89
910
W24 104
W24 117
W24 117
W24 84
W24 84
W24 84
W24 84
W24 62
W24 62
W24 62
W18 71
W18 71
W18 71
W18 71
W18 76
W18 76
W18 76
W18 71
W18 71
W18 71
W18 60
W18 60
W18 60
W18 60
W18 55
W18 55
W18 50
W18 50
W18 50
W18 50
W14 283
W14 283
W14 211
W14 211
W14 159
W14 159
W14 120
W14 120
W14 90
W14 90
W14 211
W14 211
W14 211
W14 211
W14 193
W14 193
W14 176
W14 176
W14 159
W14 159
W14 211
W14 211
W14 211
W14 211
W14 193
W14 193
W14 176
W14 176
W14 159
W14 159
W14 283
W14 283
W14 211
W14 211
W14 159
W14 159
W14 120
W14 120
W14 90
W14 90
W14 211
W14 211
W14 211
W14 211
W14 193
W14 193
W14 176
W14 176
W14 159
W14 159
W14 211
W14 211
W14 211
W14 211
W14 193
W14 193
W14 176
W14 176
W14 159
W14 159
00136
Nine-Storey
External Columns
Three-Storey
Internal Columns
Table 6.
473
Method A
Method B
Wind Loads
Dynamic Analysis
V /W
[%]
d/h
[%]
Dtop /H
[%]
T
[sec]
V /W
[%]
d/h
[%]
Dtop /H
[%]
V /W
[%]
d/h
[%]
Dtop /H
[%]
T
[sec]
Dtop /H
[%]
LA-3S
SE-3S
BO-3S
0.55
7.64
5.73
2.87
0.30
0.35
0.32
0.25
0.29
0.26
0.72
0.77
0.77
6.24
4.48
2.24
0.25
0.27
0.25
0.20
0.23
0.21
2.36
3.08
3.08
0.07
0.13
0.25
0.06
0.11
0.20
0.99
1.22
1.63
0.15
0.10
0.10
LA-9S
SE-9S
BO-9S
1.38
4.04
3.04
1.51
0.29
0.40
0.25
0.27
0.33
0.21
1.79
1.93
1.93
3.39
2.42
1.21
0.26
0.27
0.21
0.24
0.23
0.17
2.53
3.32
3.32
0.18
0.39
0.49
0.14
0.27
0.34
2.52
3.30
3.56
0.14
0.10
0.10
Table 8.
Frame
VUBC-M.A /W
[%]
VUBC-M.B /W
[%]
VWIND /W
[%]
Vy -triang. /W
[%]
Vy -unif. /W
[%]
Vy -triang. /
VUBC-M.A
Vy -triang. /
VUBC-M.B
Vy -unif. /
VWIND
LA-3S
SE-3S
BO-3S
7.64
5.73
2.87
6.26
4.48
2.24
2.36
3.08
3.08
22.94
22.38
9.74
26.88
30.23
11.33
3.00
3.91
3.39
3.68
5.00
4.35
11.39
9.81
3.68
LA-9S
SE-9S
BO-9S
4.04
3.04
1.51
3.39
2.42
1.21
2.53
3.32
3.32
7.32
10.36
7.85
11.44
11.08
8.80
1.81
3.41
5.20
2.16
4.28
6.49
4.52
3.34
2.65
00136
T
[sec]
Frame
Fundamental period, base shear, maximum drift index and roof drift (three- and nine-storey spatial MRFs).
474
Table 7.
00136
475
for three- and nine-storey spatial buildings; values due to wind actions are also
provided.
Slightly higher yield thresholds Vy /W were estimated for LA-3S, SE-3S and
SE-9S. By contrast, smaller values arise for BO-3S and LA-9S.
Over-strength factors (Vy /VUBC-A ) for the spatial configuration exceeds
perimeter values; this is not the case for BO-3S and LA-9S. Such design
values range between 2.68 and 3.90 (low-rise), 1.81 and 5.20 (medium-rise).
However, referring to the over-strength factor Vy /VW IN D , where the design is
governed by wind (SE-9S and BO-9S), the range upper bound is 3.34.
Yield stress level in LA-9S drops off by about 40% with respect to LA-9P, while
SE-9S gives rise to a Vy /VUBC-A that is nearly 30% higher than SE-9P.
As a result, it can be argued that the design of spatial MRFs is governed by
stiffness rather than strength requirements similar to perimeter configurations (see
Sec. 5.2).
5.4. Column over-strength factor
To check SCWB fulfillment, COF s were computed by means of Eq. (7); minimum
and maximum values are given in Table 9 for low-to-medium rise.
Column over-strength factors in spatial frames are greater than unity, the minimum values being between 1.28 and 2.07 and the maximum varying between 4.3 and
8.1. The latter occur at beam-to-external-column joints and can be explained by
the design choice of adopting equal sections for either external or internal columns.
However, three-storey frames exhibit on average higher COF s: in SE-3S these
factors are at least 2.07, so that the occurrence of plastic hinges in beams can be
safely predicted. Moreover, SCWB-type behaviour is likely to occur in LA-3S and
BO-3S. COF s greater than 2 were computed at all beam-to-column connections
in the first two storeys. Therefore, it can be stated that low-storey spatial frames
were designed relying on high COF s in such a way as to guarantee plastification in
beams; for perimeter frames this response can be predicted only for LA.
In medium-rise frames, COF s are greater than 2 for BO-9S, except at the roof
floor (1.38), thus the SCWB design was fulfilled. However, LA-9S and SE-9S are
Table 9. COF s (three- and nine-storey
spatial MRFs).
Frame
Minimum
Maximum
LA-3S
SE-3S
BO-3S
1.28 (3)
2.07 (3)
1.76 (3)
4.29 (2)
5.42 (2)
5.87 (2)
LA-9S
SE-9S
BO-9S
1.42 (1)
1.25 (9)
1.38 (9)
6.16 (8)
5.50 (7)
5.59 (1)
476
00136
Wind
Frame
Minimum
Maximum
Minimum
Maximum
LA-3S
SE-3S
BO-3S
0.015 (3)
0.026 (3)
0.044 (3)
0.026 (3)
0.039 (2)
0.069 (2)
0.020 (1)
0.027 (1)
0.048 (1)
0.025 (2)
0.039 (2)
0.069 (2)
LA-9S
SE-9S
BO-9S
0.018 (9)
0.018 (9)
0.029 (9)
0.061 (1)
0.098 (2)
0.134 (2)
0.042 (8)
0.034 (9)
0.053 (9)
0.061 (1)
0.109 (2)
0.123 (2)
00136
477
Therefore, the computed figures (Table 5 for perimeter and Table 10 for spatial frames), highlight a large increase of susceptibility to second order effects for
medium rather than low rise frames, either perimeter or spatial.
6. Inelastic Static Pushover Analyses
Non linear static push-over analysis is a simplified but powerful tool [Krawinkler
and Seneviratna, 1998; Mwafy and Elnashai, 2000]. It enables the assessment of the
structural behaviour in the elastic and inelastic range and hence the strength and
deformation capacity can be estimated. Therefore, the structural models described
in Sec. 3.1 were implemented and global load-deformation curves were obtained for
perimeter and spatial MRFs.
50
50
5000
5000
2000
2000
LA-3P
LA-3P
30
30
0.00
1.00
2.00
3.00
4.00
5.00
6.00
0.00
1.00
2.00
3.00
5.00
6.00
dtop
/ Htot (%)4.00
dtop / Htot (%)
1.00
1.00
SE-3P
2000
2000
4.00
4.00
5.00
5.00
6.00
6.00
SE-3S
UBC (MET.A)
YLS
ULS
1/400
30
20
1000
1000
10
0
0.00
6.00
0.000.00 1.001.00 2.002.00 3.003.00 4.004.00 5.005.00 6.00
Htot (%)
dtop /dH
toptot/ (%)
1.00
2.00
3.00
dtop / Htot (%)
4.00
5.00
6.00
50
50
2000
2000
1000
1000
0
0
0.00
1.00
2.00
3.00
4.00
5.00
6.00
0.00
1.00
2.
00/ H (%)
3.00
4.00
5.00
6.00
dtop
tot
dtop / Htot (%)
40
40
VBV/BW
/ tot
W(%)
tot (%)
1/400
VB (kN)
1/400
BO-3P
BO-3S
UBC (MET.A)
YLS
ULS
BO-3P
BO-3S
UBC (MET.A)
YLS
ULS
30
30
BO-3P
BO-3P
BO-3S
BO-3S
UBC (MET.A)
UBC (MET.A)
YLS
YLS
ULS
ULS
1/400
1/400
5000
5000
VB (kN)
2.00
3.00
2.00d / H3.00
top
tot (%)
dtop / Htot (%)
40
VB / Wtot (%)
1/400
3000
3000
VB (kN)
VB (kN)
1/400
SE-3P
(MET.A)
SE-3P SE-3S
SE-3S UBCUBC
(MET.A) YLSYLS ULSULS
3000
3000
ULS
ULS
50
5000
5000
4000
4000
YLS
YLS
20
20
0
0
0.00
0.00
UBC (MET.A)
UBC (MET.A)
10
10
1000
1000
4000
4000
LA-3S
LA-3S
1/400
1/400
40
40
VBV/BW
/W
(%)
(%)
tot tot
1/400
1/400
3000
3000
VB (kN)
VB (kN)
4000
4000
LA-3P
LA-3S
UBC (MET.A)
YLS
ULS
LA-3P
LA-3S
UBC (MET.A)
YLS
ULS
20
20
10
10
0
0
0.00
0.00
1.00
1.00
2.00
3.00
2.00dtop / H3.
00
tot (%)
dtop / Htot (%)
4.00
4.00
5.00
5.00
6.00
6.00
Figure 3. - Push-over curves with triangular distribution (3-story MRFs): single frames (left) and buildings (right).
Fig. 3. Push-over curves with triangular distribution (three-storey MRFs): single frames (left)
and buildings (right).
478
00136
Figures 3 and 4 provide the results of the analyses carried out on three- and
nine-storey frames, respectively. The results of perimeter and spatial frames, are
contrasted in the same plot. They are expressed in terms of base shear divided
by tributary seismic weight, V /W , versus top displacement normalised to building height (dtop /Htot ). It is deemed useful for comparative purposes to include in
Figs. 3 and 4, plots with curves employing the dimensional base shear V as ordinates. Similarly, vertical lines corresponding to the code inter-storey drift limit
[UBC, 1994)], i.e. d/h = 1/400, are also drawn.
In order to assess strength and deformation capacities of MRF systems, two
limit conditions, namely yield limit state (YLS) and ultimate limit state (ULS), were
defined and relevant points are indicated on the curve response. These LS definitions
were chosen consistently with (i) international codes and recommendations [UBC,
50
8000
UBC (MET. A)
YLS
ULS
1/400
40
VB / Wtot (%)
VB (kN)
6000
LA-9S
4000
LA-9P
LA-9S
1.00
2.00
SE-9P
SE-9S
1.00
2.00
UBC (MET. A)
YLS
ULS
1/400
LA-9P
30
20
2000
10
0
0.00
1.00
2.00
3.00
4.00
dtop / Htot (%)
5.00
6.00
0.00
5.00
6.00
SE-9S
UBC (MET. A)
YLS
ULS
VB / Wtot (%)
1/400
40
4000
UBC (MET. A)
YLS
ULS
1/400
SE-9P
VB (kN)
4.00
50
8000
6000
3.00
dtop / Htot (%)
30
20
2000
10
0
0.00
1.00
2.00
3.00
4.00
dtop / Htot (%)
5.00
0
0.00
6.00
8000
5.00
6.00
UBC (MET. A)
YLS
ULS
1/400
40
4000
BO-9P
BO-9S
1.00
2.00
UBC (MET. A)
YLS
ULS
1/400
BO-9S
VB / Wtot (%)
VB (kN)
4.00
50
BO-9P
6000
3.00
30
20
2000
10
0
0.00
1.00
2.00
3.00
dtop / Htot (%)
4.00
5.00
6.00
0
0.00
3.00
4.00
5.00
6.00
Fig. 4. Push-over curves with triangular distribution (nine-storey MRFs): single frames (left)
and buildings (right).
00136
479
1997; EC8, 1998; FEMA 350, 2000] and (ii) experimental and numerical studies
available in the inherent literature [Elnashai et al., 1998; Mwafi and Elnashai, 2000].
Performance criteria used to define the two LSs are briefly described in the following
paragraph; then a detailed discussion of push-over results is provided.
6.1. Yield and ultimate limit states definition
YLS corresponds to the state at which inelastic deformations begin to contribute
to the energy absorption. It can be reliably evaluated by means of static analyses
and corresponds to the onset of the yield at the member far ends.
The ULS definition appears more complex and controversial than YLS, since it
deals with the structure collapse condition, which is always conventionally defined.
In this paper different structural failure modes, both local and global, were considered, and the corresponding performance criteria were defined. In the following
section, local and global failure sources are described and the corresponding limit
values of relevant performance parameters are provided.
Local failure modes include either member or connection failure. In this paper
only connection failure, due to the attainment of plastic rotation capacity for welded
connections (set equal to SAC target plastic rotation 3%), was accounted for as a
local failure mode. Moreover, base column rotations were also considered to detect
the LSs.
The global failure modes were defined either at the attainment of a collapse
mechanism formation or when a specific threshold value of inter-storey drift,
stability index, lateral resistance reduction, were attained.
The inter-storey drift ratio (IDR) is an adequate structural parameter to assess
the MRF performance. Indeed, it can be checked easily by field evidence in the
aftermath of earthquakes as well as in experimental tests. So far, several researchers
[Leelataviwat et al., 1999, Maison and Bonowitz, 1999] have proposed different IDR
values, as a function of the probability of exceedance and the acceptable damage.
In this paper the IDR value of 4% [FEMA 350, 2000] was assumed as a rational
and reliable limit for structural integrity.
The overall stability under seismic loading implies that the structural system
may preserve its vertical load-bearing capacity at the occurrence of an input ground
motion that provokes both horizontal and vertical vibrations and hence correspondent inertial forces. Indeed, P effects of each storey of the structure can be
evaluated by means of the stability index ; in the present study the limit value of
0.30 was assumed to be the critical threshold for .
The occurrence of both local (i.e. soft storey) and global mechanisms was also
checked. It is worth pointing out that, while a global mechanism failure mode can
occur if there is not a concentration of deformation and strength demand anywhere
in the frame (thus both IDR and -values are less than the limit values), the local
mechanism is likely to be associated with the achievement of the ULSs specified
above, e.g. inter-storey drift and storey stability index.
480
00136
du /dy
Vy /VUBC
Vu /Vy
Vu /VUBC
ULS
du /dy
Vy /VUBC
Vu /Vy
Vu /VUBC
ULS
LA-3
SE-3
BO-3
4.71
2.64
2.76
2.63
3.24
3.79
1.35
1.24
1.26
3.55
4.03
4.77
Mech. (g)
Mech. (g)
3% (c)
4.48
2.86
3.21
3.00
3.91
3.39
1.97
1.49
1.64
5.27
5.81
5.60
Mech. (g)
3% (b)
3% (b)
LA-9
SE-9
BO-9
4.10
3.53
1.52
2.52
2.65
4.99
1.40
1.18
1.07
3.54
3.13
5.30
3% (b)
3% (b)
4% (1)
3.77
2.55
2.73
1.81
3.41
5.20
2.12
1.27
1.47
3.84
4.37
7.59
3% (b)
3% (b)
3% (b)
Keys: 3% = TPR; 4% = IDR; (b) = beam; (c) = column; g = global; (1) = first storey.
00136
Frame
Perimeter
Table 11.
481
482
00136
00136
483
of global behaviour, e.g. same top displacement, the inter-storey drifts and plastic
rotation demands in beams and columns are lower for the spatial than for the
perimeter solution.
7. Inelastic Time History Analysis
The present study was focused on the non-linear global response and behaviour of
the structure rather than on the detailed performance of any of its elements. To
this end, emphasis was placed on investigating the beam and column maximum rotations, storey displacements and storey drift ratios. Inelastic time history analyses
were performed on the set of three-storey and nine-storey perimeter and spatial
frames by means of the computer program DRAIN 2DX [Prakash et al., 1993]. The
aim is to evaluate and compare the seismic demand along the height for the sample
structures. The analyses were carried out by employing three acceleration histories
with different characteristics. The latter were derived from actual records of the El
Centro, Northridge and Kobe earthquakes.
It is worth mentioning that the design seismic loads adopted for the buildings
at three locations (LA, SE, BO) were quite different, since they correspond to three
different seismic hazard zones (namely, Z = 0.40 for LA, Z = 0.30 for SE, and
Z = 0.15 for BO). Nevertheless, the same ground motions, representative of severe
seismic input, were used for the seismic performance evaluation of the three sets of
buildings. The choice of this approach in the analyses is related to several reasons,
as specified in the following.
The choice of an accelerogram is a very complex task due to the uncertainties
involved. At the same site, as a result of the same source, the ground motions may
be very different in character for different events. The use of artificial ground motions, which can be generated with peak ground acceleration (PGA) matching those
specified for the seismic zone, may be questionable due to the poor frequency content of the generated acceleration history when compared to actual seismic records
[Broderick and Elnashai, 1996]. Furthermore, the use of scaled natural records,
obtained by either amplifying or reducing the PGA without changing other characteristics (periods, duration, velocities, etc.) is also debatable [Bommer and Scott,
2000].
Finally, the analysis of the MRF design process, carried out in Secs. 4 and
5, has shown that stiffness, SCWB and stability, rather than strength (i.e. value
of the design base shear), are the governing design issues. Thus, a satisfactory
performance even under severe earthquakes, can be expected for MRF buildings
when the above design issues have been addressed, independently of the seismic
zone. Due to the fundamental period of vibration, i.e. 0.99 sec to 3.56 sec, a set
of accelerograms with near- and far-field effects were selected for the nonlinear
dynamic analyses. The latter were, however, conducted by using the same un-scaled
historical records for all MRF buildings.
484
00136
Date
Station
Component
Duration (sec)
PGA (g)
18.5.40
17.1.94
17.1.95
El Centro
Newhall
Kobe
S00E
340N/118W
EW3
53.80
59.98
56.40
0.348
0.583
0.834
2.5
ElCentro
Kobe
New ha ll
ElCentro
Kobe
New hall
SV (m/sec)
1.5
1.0
1.0
0.5
0.5
0.0
0.0
0.0
1.0
2.0
3.0
4.0
5.0
0.0
1.0
T(sec)
2.0
3.0
T(sec)
Fig. 5.
4.0
5.0
00136
Sa (g)
2.0
1.5
2.0
3.0
485
LA -3P LA -3S
SE-3P
Fig. 6.
SE-3S
0.00
BO-3P BO-3S
LA -9P LA -9S
SE-9P
Roof drifts for perimeter and spatial MRFs: three-storey (left) and nine-storey (right).
SE-9S
&
&
&
&
&
&
&
0.00
BO-9P BO-9S
&
&
&
&
&
&
&
&
Newhall
&
%
%
%
Three-Storey
ElCentro
$
$
$
#
#
2.00
#
"
"
"
"
!
'
'
'
'
6.00
"
"
"
"
"
"
"
"
!
!
1.00
4.00
5.00
Kobe
5.00
Kobe
4.00
Nine-Storey
00136
3.00
Newhall
1.00
2.00
ElCentro
486
6.00
3.00
00136
487
minimum and maximum values are 0.84% (LA-9S) and 1.52% (SE-9S), which are
comparable with the narrow range, e.g. 1% to 1.5%, evaluated earlier for perimeter
frames.
7.2.2. Inter-storey drifts
A comparison of inter-storey displacements is provided in bar-chart format in Fig. 7.
Inter-storey drift is adimensionalised with regard to inter-storey height (d/h).
The results show that the maximum drifts are generally lower than the threshold value of 4%, corresponding to an inter-storey drift capacity (IDC) for MRFs
classified as special [FEMA 350, 2000]. Values beyond 4% occur for the Kobe earthquake, which frequently gives rise to high values of inelastic deformation demand.
The major issues mentioned earlier for top displacements are confirmed from the
drift results. However, a critical assessment of inter-storey drift values can provide further information on the localisation of the plastic demand throughout the
structural system.
Medium-rise spatial frames exhibit d/h values (Fig. 7) on average lower than
the perimeter ones. The results for the LA frame do not follow the same trend. The
inter-storey drifts computed for spatial configurations are always lower than for the
perimeter (except for LA). The scatter is lower for the spatial frames (1.40% and
3.50% are the minimum and maximum values of d/h) than for perimeter frames
(1.36% and 4.66% are the correspondent minimum and maximum d/h).
It is remarkable to highlight that in high (LA) and medium (SE) seismic areas,
the demand tends to be uniformly distributed, whilst a large variation characterises
the response of BO frames (low seismicity). The latter is due to the assumptions
adopted in the design. In the case of BO perimeter frames the SCWB requirements are not fulfilled, but they are fulfilled for the spatial configuration. Thus,
different plastic rotation demands are expected for such alternative configurations.
The envelope of the distribution of the plastic rotations along the height of BO-9P
shows that a concentration of plastic demand affects the first floor, thus leading to
a soft storey mechanism. Similar envelopes, for the other frames, demonstrate that
no soft mechanisms occur and the maximum plastic excursions affect the upper
storeys, without any detrimental effect on the global hysteretic dissipation.
The maximum inter-storey drifts for low-rise buildings are provided in Fig. 7.
By comparing the results, it may be observed that spatial frames exhibit higher
values of inter-storey drift (minimum d/h = 1.62% and maximum d/h = 5.06%);
the highest values, greater than 4.5%, occurs for the Kobe record. For the perimeter
frames a reduced variation of drift values is found. LA-3P experiences d/h = 1.70%
for the El Centro record, whilst the maximum value is 3.83% and is due to BO-3P
(Kobe ground motion).
7.2.3. Plastic rotations
Maximum plastic rotations for both perimeter and spatial typologies and low-tomedium rise buildings are provided below with regard to the beams (Fig. 8) and
LA -3P LA -3S
Fig. 7.
SE-3P
SE-3S
1.00
0.00
BO-3P BO-3S
LA -9P LA -9S
SE-9P
SE-9S
Inter-storey drifts for perimeter and spatial MRFs: three-storey (left) and nine-storey (right).
P
PJ
JD
JD
JP
JP
JD
PJ
OI
IC
JP
IO
IC
HN
HB
MG
OI
IO
4.00
OI
IC
MG
Newhall
OI
IC
IO
IC
NH
HB
MG
GA
Nine-Storey
OI
IC
HN
HB
MG
GA
LF
F@
IDC
ElCentro
NH
HB
HN
HB
MG
MG
GA
GA
LF
F@
KE
>
>
>
>
<
<
<
<
6.00
LF
F@
LF
F@
LF
F@
3.00
KE
;5
;5
KE
E?
KE
E?
1.00
?
;5
Three-Storey
;5
:4
:4
.4
.4
93
93
-3
82
71
4.00
;5
5/
:4
5/
:4
4.
4.
.4
.4
93
3-
93
-3
82
82
2,
2,
71
1+
17
1+
60
0*
0*
60
5.00
;5
5/
5/
:4
4:
4.
4.
.4
.4
93
3-
93
-3
82
82
2,
2,
71
1+
17
1+
60
0*
0*
IDC
Kobe
5.00
Kobe
0.00
BO-9P BO-9S
00136
3.00
Newhall
2.00
60
ElCentro
488
6.00
LA -3P LA -3S
Fig. 8.
SE-3P
SE-3S
e
0.00
BO-3P BO-3S
LA -9P LA -9S
SE-9P
SE-9S
Newhall
0.05
Nine-Storey
0.03
TPR
0.00
BO-9P BO-9S
Kobe
00136
Beam plastic rotations for perimeter and spatial MRFs: three-storey (left) and nine-storey (right).
m
j
p
0.04
ElCentro
l
r
0.06
j
p
max (rad)
0.02
0.01
o
0.03
Three-Storey
Kobe
Newhall
0.05
ElCentro
0.02
TPR
0.01
T
0.04
max (rad)
0.06
489
490
00136
columns (Fig. 9). In all bar charts the threshold of 0.03 rad (3%), target plastic
rotation (TPR) of beam-to-column connections as defined within the SAC Steel
Project [FEMA 350, 2000], is drawn.
The end beam rotations for medium rise perimeter frames (Fig. 8) range from
a lower bound of 1.01% (LA-El Centro) to an upper limit of 3.33% (BO-Kobe).
Kobe is the most severe earthquake case: for all seismic zones the beams undergo
plastic rotations greater than 2%. By contrast, the least demanding record is El
Centro; it gives rise to plastic rotations of 1.07% on BO, 1.01% for LA and 1.12%
in SE frame. Intermediate values ranging between 1.25% (LA) and 2.22% (SE) are
induced by Newhall ground motion.
A smoothed variation characterises the plastic demands on nine-storey spatial
frames. The minimum plastic rotation was computed for BO-El Centro (1.23%)
while the maximum (3.15%) is reached in the LA frame when the Kobe record is
considered. The two sets of values show that, except for Kobe, the plastic rotation
demands are lower than the 3% TPR required by SAC. The latter is a direct
consequence of the SCWB fulfilment, adopted as a specific design target for spatial
frames.
Maximum plastic rotations in low-rise perimeter and spatial MRFs are also
provided (Fig. 8). The values of inelastic demands in the beams of perimeter and
spatial MRFs are quite close and do not generally overcome the 3% limit value.
The Kobe earthquake provokes the largest plasticity in the beams of BO and SE
frames (respectively 5.13% and 5.50%). These results may be justified in the light
of the frequency content of Kobe. It is particularly severe in the neighbourhood of
natural periods of low-rise frames. High values of beam rotations can be found in
the case of perimeter as well as spatial frames; they were deliberately designed with
similar fundamental periods.
For the sake of completeness, the maximum plastic rotations in the column
elements of the nine- and three-storey frames, both perimeter and spatial, are also
considered. In the case of perimeter configurations (Fig. 9) the nine-storey Boston
frame is characterised by relevant plastic demands, especially with regard to the case
of the Newhall record (maximum rotation 3.53%), that corresponds to the highest
demand for the perimeter configuration. The behaviour of the column elements
of the LA perimeter frame is almost elastic, since the maximum value is equal to
0.08%. The comparison with the spatial configurations suggests that for all but the
LA and SE frames under the Kobe ground motion, the columns are in the elastic
range.
The values for the column plastic rotations of the three-storey frames are also
shown in Fig. 9. The scenario outlined is quite different from the aforementioned,
with regard to the spatial frames where the adopted design philosophy is slightly
different from that adopted for the nine-storey spatial frames. While the plastic
rotations required in the columns of the spatial configuration are lower than in
perimeter layouts, some plastifications in the columns occur. Nevertheless, since
LA -3P LA -3S
Fig. 9.
SE-3P
SE-3S
BO-3P BO-3S
LA -9P LA -9S
SE-9P
SE-9S
TPR
0.03
0.05
Newhall
Nine-Storey
0.00
BO-9P BO-9S
0.06
Kobe
00136
Column plastic rotations perimeter and spatial MRFs: three-storey (left) and nine-storey (right).
0.01
0.04
ElCentro
Kobe
0.02
0.01
max (rad)
Three-Storey
TPR
0.05
0.03
Newhall
ElCentro
0.02
0.00
~
0.04
max (rad)
0.06
491
492
00136
the design was based upon the fulfilment of SCWB, the maximum plastic rotations
take place in the base column ends.
The comparison between inter-storey drifts (Fig. 7) and beam plastic rotations
(Fig. 8) shows close values for both set of data (low-to-medium rise and perimeterspatial), especially for SCWB frames. It is, therefore, confirmed, as in previous
studies [Mele et al., 1995], that plastic rotation can be predicted via the interstorey drift index. Inelastic inter-storey drift can be related to the elastic interstorey drift by means of the displacement amplification factor Cd , thus a reasonable
prediction of plastic rotation demands can be obtained by means of a simple elastic
analysis.
7.2.4. Hysteretic energy
Inelastic time history analyses also indicate the hysteretic energy dissipated during
the ground motions. In Fig. 10 the energy time histories for perimeter and spatial
Fig. 10.
Hysteretic energy diagrams: three-storey (left) and nine-storey (right) MRF buildings.
00136
493
MRF buildings, under the El Centro, Newhall and Kobe seismic inputs, are provided. They were computed by considering the energy dissipated by each MRFs and
accounting for the actual number of frames used to withstand horizontal forces.
It can be observed that the energy dissipated by the three pairs (LA, SE and BO)
of buildings configurations (perimeter, spatial) is quite close. The total dissipated
energy is a function of the building natural period and of the earthquake ground
motion.
With regard to the ground motion, Newhall represents the worst case scenario
for the set of assessed buildings: the energy varies in the range 5000 kNm (BO3) and 10 000 kNm (LA-9). Due to the higher values of beam plastic rotations
(greater than 4%) and inter-storey drifts (around 3%) SE-3 MRFs dissipate a large
amount of energy; the maximum values are comparable to the LA counterparts.
These results were also found for medium-rise buildings; in this case, though, the
influence of higher-mode effects gives rise to more complex responses. Concerning
the dependence of the hysteretic energy on the building natural period, it may be
observed that lower energy values can be found for longer period buildings (e.g.:
BO-9 versus LA-9), as a consequence of a sort of self-isolation effect. As a result,
the energy dissipated by the three pairs (LA, SE and BO) of buildings configurations
(perimeter, spatial) is quite close. Therefore, it can be argued also that in terms of
hysteretic energy, the dynamic response of the perimeter and spatial MRFs is fairly
similar; thus, their equivalent behaviour is confirmed.
8. Concluding Remarks
In this paper a set of perimeter frame buildings was analysed in the linear and
nonlinear range. An alternative structural solution, i.e. spatial MRFs, was then
designed for the same buildings. On the basis of the analysis results, some aspects
worthy of remark are reported in the following.
The main aspects of the structural behaviour of perimeter and spatial frames and
the differences arising from them were investigated through static and dynamic
inelastic dynamic analyses. The latter confirmed the results of the pushovers
(with triangular and uniform distributions). These results were expressed and
contrasted in terms of (i) plastic rotations for beams and columns, (ii) interstorey drifts, (iii) roof drifts and (iv) hysteretic energy. On the basis of these
comparisons it can be stated that the seismic response of the perimeter and
spatial MRFs is fairly similar. Therefore, an equivalent behaviour between the
two configurations can be obtained if the design is consistent.
The elastic analyses have provided the following information on the design of
the assessed buildings. The design is governed by stiffness rather than strength
requirements, thus the stress level under design seismic forces is quite low. The
elastic critical multiplier of vertical loads and the column to beam strength ratio
were estimated for the three buildings; they show a significant variation with the
seismic zone.
494
00136
The spatial MRF solution was designed with the aim of obtaining close values
of the fundamental periods and of the yield strength as the perimeter frame
buildings. SCWB behaviour is expected for the frames since an adequate columnto-beam strength ratio was assigned at the frame joints and an adequate safety
against elastic critical load enable the prediction of negligible P effects.
As a result of the static nonlinear analyses (pushovers), a global over-strength on
average equal to 4 and 5, respectively for the three-storey perimeter and spatial
frames, and equal to 33.5 and 4.5, respectively for the nine-storey perimeter and
spatial frames, was derived. For all but the BO frames a yield multiplier of the
design load distribution approximately equal to 3 has been found. Moreover, a
different extent of plastic redistribution has been evidenced in the perimeter and
spatial frames. The latter was quantified through the u /y coefficient, which in
average is equal to 1.11.3 for perimeter frames and to 1.41.5 for spatial frames.
The comparison between inter-storey drifts and beam plastic rotations shows
quite close values, especially in the frames where the SCWB design was a specific
design target. It is, therefore, confirmed, as in previous studies [Mele et al., 1995],
that plastic rotation can be predicted via inter-storey drift index, which can be
related to the elastic analysis results.
The evaluation of the energy dissipated in the buildings points out that it strongly
varies as a function of the input ground motion and of the building fundamental period. With regard to the latter, lower energy values can be found for
longer period buildings (e.g.: BO-9 versus LA-9), as a consequence of a sort of
self-isolation effect.
Furthermore, considering that the other performance parameters examined in the
paper (roof and inter-storey drifts, plastic rotations) do not assume very different
values for buildings designed at different locations (i.e. different seismic zones),
it can be argued that a well-designed MRF (fulfilment of stiffness, SCWB,
stability requirements) has a good-to-excellent performance, independently of
the lateral load level assumed in the design.
Acknowledgements
The research herein was supported by the Italian Ministry of University and
Scientific Research (MURST) within the framework of PRIN99; the financial
support of MURST is gratefully acknowledged.
References
Bommer, J. J. and Scott, S. G. [2000] The feasibility of using real accelerograms for
seismic design, Proc. of the 3rd Japan-UK Workshop on Implications of Recent
Earthquakes on Seismic Risk, London, UK.
Broderick, B. M. and Elnashai, A. S. [1996] Seismic response of composite frames, part 1.
Response criteria and input motion, Engineering Structures 18(9), 696706.
Chopra, A. K. and Goel, R. K. [2000] Building period formulas for estimating seismic
displacements, Earthquake Spectra 16(2), 533536.
00136
495
Computer and Structures Inc. [1999] SAP2000 static and dynamic finite element
analysis of structures. Non-linear version 7.12, Berkeley, California.
Elnashai, A. S., Elghazouli, A. Y. and Danesh Ashtiani, F. A. [1998] Response
of semi-rigid steel frames to cyclic and earthquake loads, Journal of Structural
Engineering 124(8), 857867.
Eurocode 8 [1998] Design provisions for earthquake resistance of structures. Part 1.3:
General rules. Specific rules for various materials and elements, Commission of European Communities, Brussels, Belgium.
Federal Emergency Management Agency (FEMA) [1995] FEMA 267. Interim guidelines: modification and design of welded steel moment frame structures, Report
No. SAC95-02, Washington, D.C.
Federal Emergency Management Agency (FEMA) [1997] Supplement to FEMA
267 (FEMA 267A). Interim guidelines. Advisory no. 1, Report No. SAC96-03,
Washington, D.C.
Federal Emergency Management Agency (FEMA) [1999] Supplement to FEMA 267
(Report FEMA 267B). Interim guidelines. Advisory no. 2, Report No. SAC9nine-01,
Washington, D.C.
Federal Emergency Management Agency (FEMA) [2000] Recommended seismic design
criteria for new steel moment-frame buildings, Report No. FEMA 350, Washington,
D.C.
Gupta, A. and Krawinkler, H. [1998a] Influence of design parameters on connection
demands, Structural Engineering World Wide, Paper No. T158-1.
Gupta, A. and Krawinkler, H. [1998b] Quantitative performance assessment for steel moment frame structures under seismic loading, Proc. of the 11th European Conference
on Earthquake Engineering, Paris, France.
Gupta, A. and Krawinkler, H. [2000a] Behavior of ductile SMRFs at various seismic
hazard levels, Journal of Structural Engineering 126(1), 98107.
Gupta, A. and Krawinkler, H. [2000b] Dynamic P-Delta effects for flexible inelastic steel
structures, Journal of Structural Engineering 126(1), 145154.
Horne, M. R. [1975] An approximate method for calculating the elastic critical loads of
multi-storey plane frames, The Structural Engineering 53(6), 242248.
International Conference of Building Officials (ICBO) [1994] Uniform building code.
Vol. 2, Whittier, California.
International Conference of Building Officials (ICBO) [1997] Uniform building code.
Vol. 2, Whittier, California.
Krawinkler, H. and Seneviratna, G. D. P. K. [1998] Pros and cons of a pushover analysis
for seismic performance evaluation, Engineering Structures 20(46), 452464.
Leelataviwat, S., Goel, S. C. and Stojadinovic, B. [1999] Toward performance based
seismic design of structures, Earthquake Spectra 15(3), 435461.
Luco, N. and Cornell, C. A. [2000] Effects of connection fractures on SMRF seismic drift
demands, Journal of Structural Engineering 126(1), 127136.
Maison, B. and Bonowitz, D. [1999] How safe are pre-Northridge WSMFs? A case of the
SAC Los Angeles nine storey building, Earthquake Spectra 15(4), 765789.
Mele, E., DAmore, E. and De Luca, A. [1995] Design criteria and plastic rotation requirements in steel frames subjected to seismic loadings, Proc. of the 15th CTA Congress,
Riva del Garda, Italy.
Mele E., De Luca, A. and Di Sarno, L. [2000] Design aspects affecting the seismic behaviour of steel MRF buildings: Analysis of three case studies, Proc. of the 12th
World Conference on Earthquake Engineering, Auckland, New Zealand.
Mwafy, A. M. and Elnashai, A. S. [2000] Static pushover versus dynamic collapse analysis
of RC buildings, Engineering Structures 23(5), 407424.
496
00136