Escolar Documentos
Profissional Documentos
Cultura Documentos
2/3
Contents
4/5
from page 6
from page 10
from page 40
With the natural and active cooling functions, a heat pump can
also be used to cool living spaces. Most Viessmann heat pumps
are already equipped with this function.
from page 64
from page 80
from page 88
Introduction
6/7
Introduction
VITOCAL 300
Heat pump
Compression process
55C
Ground
temperature all year round between 5 and 18C (at 2m depth)
8/9
Ground source
(collector)
Ground source
(probe)
Ground source
(ice store)
Air source
5
4
1
1
2
3
1
4
5
10/11
Heat pumps
VITOCAL
As a homeowner, it is easy to become frustrated at the constantly rising prices of fossilfuels.
Why not make yourself independent of them, by relying on proven technology instead?
Vitocal heat pumps from Viessmann utilise
the natural heat from the environment. It is
unlimited and free. This heating technology
is amongst the most economical and clean
of all options for heat production. To ensure
that this remains the case and that heat
pump technology is continuously improved
and therefore becomes even more efficient,
Viessmann is putting innovative development
and improvement at the top of its list.
Milestones in Viessmann
heat pump development
Heat pump
Split heat
pumps with
temperature with
DC inverter
EVI process
technology
In-house
development,
first standard
2010
heatpump
2009
Heat pump
controlunit with
integral natural
cooling function
First standard
HxR heat
the refrigerant
circuit
First Viessmann
heating heat
1996
pumps
S08 and L08
1978
Patent
1982
1998
2007
2008
Refrigerant
compensated heat
pump control unit
for mono and dual
mode systems
(Oktamatik)
utilitymodel
heatingcentres
RCD system
Patent pending
passive house
Electronic expansion
Integral operating
compact
valve (EEV)
manual
appliance
In series production
Vitotres 343
First weather-
utilisation in
3-D sound concept
Registered
2002
swirl vane in
Vitovent 300-F
PV own power
distribution
production
exchanger with
2003
2005
Domestic
ventilationsystem
Coated evaporator
2012
controller
Product range
Heat pumps
1.5 to 2000kW
Page 16
VITOCAL 350-G
Two-stage heat pump
(master/slave)
Brine/water heat pump: 14.6 to 37.4kW
Water/water heat pump: 20.6 to 51.4kW
Page 16
Page 20
VITOCAL 300-G
Single stage heat pump
Brine/water heat pump: 5.9 to 42.8kW
Water/water heat pump: 7.9 to 58.9kW
Page 24
VITOCAL 300-G
Two-stage heat pump
(master/slave)
Brine/water heat pump: 11.8 to 85.6kW
Water/water heat pump: 15.8 to 117.8kW
For new build and modernisation
Detached houses, apartment buildings, commercial property
Page 28
12/13
Page 30
Heat pumps up to 2 MW
For heating and/or cooling
Group
Page 32
VITOCAL 200-G
Brine/water heat pump
5.8 to 17.2kW
Page 36
Natural/active cooling
NC-Box
Natural cooling box
Up to 5kW cooling capacity
AC-Box
Active cooling box
Up to 13kW cooling capacity
Page 42
Product range
Heat pumps
1.5 to 2000kW
Page 44
VITOCAL 300-A
Air/water heat pump
(internal or external installation)
3 to 9kW, modulating
Page 48
VITOCAL 242-S/222-S
Split compact heat pump
(air/water)
3 to 10.6kW
Vitocal 242-S cylinder capacity: 220 l, with solar function
Vitocal 222-S cylinder capacity: 170 l
Page 52
VITOCAL 200-S
Split air/water heat pump
3 to 10.6kW
For new build and modernisation
Detached houses
Dual mode systems
Page 56
14/15
Page 62
Page 66
VITOVENT 300
Domestic ventilation system with heat recovery
for demand-dependent domestic ventilation
180 m3 /h
300 and 400 m3 /h with integral bypass circuit
Page 68
Heat pumps
Vitocal 350-G
16/17
VITOCAL 350-G
Heat pump with a maximum flow temperature of 72C.
The first choice for high DHW convenience in detached houses and apartment buildings.
Heat pumps
Vitocal 350-G
2
3
Vitocal 350-G
Type BWC 351.A
4
1
2
18/19
Heat pumps
Vitocal 343-G
Vitocal 333-G
20/21
VITOCAL 343-G
VITOCAL 333-G NC
VITOCAL 333-G
System solutions for detached houses
Vitocal 333-G, compact brine/water heat pump with DHW cylinder
Vitocal 333-G NC, including all components for natural cooling
Vitocal 343-G, generally including the option to connect to a solar thermal system
Heat pumps
Vitocal 343-G
Vitocal 333-G
Always accessible
Subject to demand, the Vitotronic control unit
can be fitted with convenient communication
technology. From Vitocom 100 to
Vitocom300, versatile remote monitoring
and remote control options are available,
independent of the system user's location.
3
Vitocal 333-G
3
4
5
6
7
8
DHW cylinder,
170litre capacity
Vitotronic 200
heat pump control unit
Internal indirect coil
cylinder heating
Primary pump
(high efficiency pump)
Secondary pump
(high efficiency pump)
Hermetically sealed
Compliant scroll
compressor
Diverter valve
heating/DHW
Integral instantaneous
heating water heater
Small footprint
With their space saving designs, the
Vitocal343-G and Vitocal 333-G are
particularly suitable for situations where
space is restricted. The brine circulation
pump, heating circuit pump and the 3-way
diverter valve are already integrated inside
the compact casing that completely
protects the refrigeration module/hydraulic
compartment from the outside environment
and, in conjunction with the three-dimensional
anti-vibration mounts, minimises operating
noise. These compact heat pumps are some
of the quietest in their category, as they only
generate 38 dB(A) at brine 0C/water 35C.
7
4
5
22/23
Compact brine/water heat pumps with heating outputs from 5.9 to 10.3kW
Low operating costs through high coefficients of performance: COP to EN 14511
of 4.7 (brine 0C/water 35C)
High DHW convenience through integral DHW cylinder with 220litre capacity in
the Vitocal 343-G (Vitocal 333-G with 170litre capacity)
Maximum flow temperature of up to 60C for high DHW convenience
Integral power saving high efficiency pumps (Energy Label A)
Very quiet thanks to a new sound insulation concept resulting in a sound power
level of 38 dB(A) at brine 0C/water 35C
Vitotronic control unit that is easy to operate with plain text display
Ready to connect, ex works
Easy handling through reduced height and split casing
Convenient and compact through integral NC (natural cooling) function for the
Vitocal 333-G
Can be extended with convenient communication technology
Instantaneous heating water heater integrated as standard
Optimised utilisation of self-generated power from photovoltaic systems
For specification, see page 71
Heat pumps
Vitocal 300-G
24/25
VITOCAL 300-G
The Vitocal 300-G heat pump utilises the renewable heat stored underground or in
groundwater. A two-stage version is available for high heating outputs.
Heat pumps
Vitocal 300-G
2
3
Vitocal 300-G
4
5
2 Condenser
3
26/27
Maximum efficiency for new build and modernisation in detached houses and
apartment buildings
Brine/water heat pump
Heating outputs, single stage: 5.9 to 17.0kW; two-stage: 11.8 to 34.0kW
Water/water heat pump
Heating outputs, single stage: 7.9 to 23.0kW; two-stage: 15.8 to 46.0kW
Vitocal 300-G: with integral high efficiency pump for brine and heating circuits,
plus circulation pump for cylinder heating, safety assembly with safety valve,
pressure gauge and air vent valve (for types BWC and WWC)
Low operating costs through high coefficients of performance: COP value to
EN14511 up to 4.9 (brine 0C/water 35C) and integral high efficiency pumps
(for Vitocal 300-G, types BWC and WWC)
Maximum flow temperatures up to 60C
High efficiency all year round at any operating point through innovative
RCDsystem with electronic expansion valve
Extremely quiet operation below 42 dB(A) through sound-optimised
appliancedesign
Vitotronic 200 control unit with energy statement (meets BAFA subsidy terms
[Germany])
Master/slave solutions for very high flexibility, for example combination of
Vitocal 300-G and 350-G
For specification, see page 72
Heat pumps
Vitocal 300-G
2
3
4
Vitocal 300-G
2
3
Weather-compensated, digital
Vitotronic200 heat pump control unit
Condenser
Large area evaporator for efficient
heattransfer
Hermetically sealed Compliant scroll
compressor
Electronic expansion valve
28/29
Heat pumps
Easy-to-operate Vitotronic
control unit with plain text and
graphicdisplay
30/31
Heat pumps
Vitocal 242-G
Vitocal 222-G
32/33
VITOCAL 242-G
VITOCAL 222-G
Compact brine/water heat pumps with DHW cylinder and, as an alternative,
the option to connect a solar thermal system.
Solar collectors
Vitocal 242-G
Heat pumps
Vitocal 242-G
Vitocal 222-G
2
3
Vitocal 242-G
1
Heating lance
2 Enamelled
DHWcylinder
3 Vitotronic 200 heat
pump control unit
4 Integral solar indirectcoil
5 PWM-controlled
cylinder primary pump
(pulse width modulation)
6 Primary circulation pump
7 Secondary circulation
pump
8 Diverter valve
heating/DHW
9 Integral instantaneous
heating water heater
8
6
7
34/35
Compact brine/water heat pumps with heating outputs from 5.9 to 10.0kW
Low operating costs through high coefficients of performance: COP to EN 14511
up to 4.3 (brine 0C/water 35C)
Maximum flow temperature: 60C
High DHW convenience through integral DHW cylinder with 220litre capacity in
the Vitocal 242-G (Vitocal 222-G with 170litre capacity)
Very quiet thanks to the sound-optimised appliance design with a sound power
level of 43 dB(A) at 0/35C
Vitotronic control unit that is easy to operate with plain text display
Ready to connect, ex works
Easy handling through small footprint, reduced height and split casing
Easy installation through variable connection accessories
Can be extended with convenient communication technology
Instantaneous heating water heater integrated as standard
Optimised utilisation of self-generated power from photovoltaic systems
For specification, see page 75
Heat pumps
Vitocal 200-G
36/37
VITOCAL 200-G
Attractively priced heat pump for uncomplicated heat supply and high level of
DHWconvenience in new build.
Heat pumps
Vitocal 200-G
2
3
Vitocal 200-G
5
1
2
3
4
5
38/39
40/41
Heat pumps
AC-Box
Optional equipment for
Viessmann heat pumps to
provide active cooling
Page 43
Natural cooling
NC-Box
Active cooling
AC-Box
42/43
Heat pumps
Vitocal 350-A
44/45
VITOCAL 350-A
Thanks to high flow temperatures, a heating system can even be modernised with
an air/water heat pump.
Heat pumps
Vitocal 350-A
Spot on
If the heat pump is installed outside, the heat
needs to be "transported" to the interior of the
house. In this, you can rely on Viessmann's
competence in heating systems. All the
pipework required for routing underground,
as well as the entire range of accessories,
are provided from one single source, and are
perfectly matched to one another.
3
4
Vitocal 350-A
6
7
Intake side
Discharge side
3 Evaporator
4 Radial fan
5 Electronic expansion valve
6 Evaporator for intermediate injection
7 Hermetically sealed scroll compressor
withvapour injection (EVI)
2
46/47
Air/water heat pump, mono mode with a heating output of 10.6 to 18.5kW for
DHW and central heating
Particularly suitable for modernisation through 65C flow temperature, even at
cold outside temperatures in winter
DHW temperature subject to system version up to 55C
Low operating costs through high coefficients of performance: COP to EN 14511
up to 3.6 (air 2C/water 35C)
High efficiency all year round at any operating point and therefore low
consumption costs through the innovative RCD (Refrigerant Cycle Diagnostic)
system, with an electronic bi-flow expansion valve (EEV)
Low operating noise through radial fan, sound-optimised appliance design and
night operation with reduced fan speed
Easy-to-operate Vitotronic 200 heat pump control unit with TeleControl and
remote monitoring for connection to the Vitocom 100, 200 or 300, plus cascade
function for up to five heat pumps
Installation inside or outside with matching accessories
As an option with high efficiency pump for the heating circuit with Vitocal 350-A
(internal installation)
Efficient defrosting through circuit reversal
With integral energy statement
For specification, see page 77
Heat pumps
Vitocal 300-A
48/49
VITOCAL 300-A
With modulating air/water heat pumps, advanced technology guarantees the highest level
of efficiency in any operating state.
Heat pumps
Vitocal 300-A
1
2
4
5
Vitocal 300-A
1 Evaporator
2
Radial fan
Electronic expansion valve
4 Condenser
5 Digital scroll compressor
3
50/51
Reversible air source heat pump for heating and cooling, for installation
insideand outside
Variable output control from 3.0 to 9.0kW
Low operating costs through high coefficients of performance: COP to EN
14511: 3.9 (air 2C/water 35C); 4.4 (air 7C/water 35C)
Maximum flow temperature up to 60C at 6C outside temperature
High efficiency all year round at any operating point and therefore low
consumption costs through the innovative RCD (Refrigerant Cycle Diagnostic)
system, with an electronic bi-flow expansion valve (EEV)
Low operating noise through radial fan, sound-optimised appliance design and
night operation with reduced fan speed
Easy-to-operate Vitotronic 200 heat pump control unit with TeleControl and
remote monitoring for connection to the Vitocom 100, 200 or 300, plus cascade
function for up to five heat pumps
Integral high efficiency pump for the heating circuit with the Vitocal 300-A
(internal installation)
Efficient defrosting through circuit reversal
With integral energy statement
Particularly quiet in "silent version"
Active cooling mode possible through reversible refrigerant circuit
For specification, see page 77
Heat pumps
Vitocal 242-S
Vitocal 222-S
52/53
VITOCAL 242-S
VITOCAL 222-S
Compact split air source heat pumps for new build and modernisation, with integral
DHWcylinder for a high level of DHW convenience.
Heat pumps
Vitocal 242-S
Vitocal 222-S
Vitocal 242-S
Internal unit (left)
2
3
Heating lance
2 Enamelled
DHWcylinder
3 Vitotronic 200 heat
pump control unit
4 Integral solar indirectcoil
5 Diverter valve
heating/DHW
6 High efficiency pump
7 Condenser
8 Integral instantaneous
heating water heater
Vitocal 200-S
External unit (right)
1 Evaporator
2
Fan
3 Compressor
1
2
54/55
Attractively priced split air source heat pump with heating outputs between
3.0and 10.6kW (air 2C/water 35C at the nominal operating point)
Inverter compressor for optimum output matching to the heating and
coolingdemand
Low operating costs through high coefficients of performance: COP to EN 14511
of up to 4.6 (air 7C/water 35C) and 3.5 (air 2C/water 35C)
Maximum flow temperature up to 55C at -15C outside temperature
(with reduced output)
High DHW convenience through integral DHW cylinder with 220litre capacity
for the Vitocal 242-S (for Vitocal 222-S with 170litre capacity)
Solar connection for DHW heating with the Vitocal 242-S
Convenient through reversible version that enables heating and cooling
High efficiency in partial load operation through output-controlled compressor
Low sound power level of the external unit in partial load operation through
variable speed fan and compressor
Refrigerant pipework requires no frost protection
Vitotronic 200 control unit that is easy to operate with plain text
and graphic display
Low investment outlay
Easy and affordable installation without major wall outlets
Optimised utilisation of self-generated power from photovoltaic systems
Can be commissioned by Viessmann's Technical Service department
For specification, see page 78
Heat pumps
Vitocal 200-S
56/57
VITOCAL 200-S
The affordable alternative for new build and modernisation, which can also be easily
combined with existing heat sources.
Vitocal 200-S
DHW
Vitocal 200-S
DHW
cylinder
External and
cylinder
internal unit
Boiler
Heating water
buffer cylinder
Heat pumps
Vitocal 200-S
Vitocal 200-S
Internal unit
1
Integral instantaneous
heating water heater
Heat exchanger
(condenser)
3 3-way diverter valve
4 High efficiency pump
(compliant with
EnergyLabel A)
5 Vitotronic 200
4
6
Vitocal 200-S
External unit
1 Evaporator
2 Fan
3 Compressor
58/59
Attractively priced split air source heat pump with heating outputs between
3.0and 10.6kW (air 2C/water 35C at the nominal operating point)
Output control and DC inverter for high efficiency in partial load operation
Low operating costs through high coefficients of performance: COP to EN 14511
of up to 4.6 (air 7C/water 35C) and 3.5 (air 2C/water 35C)
Maximum flow temperature up to 55C at -15C outside temperature
(with reduced output)
Weather-resistant external unit with evaporator, compressor, expansion valve
and fan
Internal unit with high efficiency circulation pump (compliant with Energy
LabelA), heat exchanger, 3-way diverter valve, safety assembly and control unit;
for heating/cooling version with integral instantaneous heating water heater
Vitotronic 200 heat pump control unit that is easy to operate with plain text
andgraphic display
Convenient thanks to reversible version that enables heating and cooling
Can be commissioned by Viessmann's Technical Service department
Optimised utilisation of self-generated power from photovoltaic systems
For specification, see page 78
The Vitocal 200-S utilises the outdoor air heated by the sun
and on cold days, a second heat source can be switched on
automatically by the heat pump control unit.
60/61
Oil boiler
Oil boiler
Output
Proportion of annual heating load
Annual heat demand
Efficiency when heating
Energy demand
Proportion of DHW
Energy consumption
Energy price*
Consumption costs*
18kW
100%
32,400kWh
90%
36,000kWh
3000kWh
3900 litres oil
0.85 per litre
3315
18kW
20%
6480kWh
90%
7200kWh
3000kWh
1020 litres oil
0.85 per litre
867
Total*
3315
1967
Savings
approx. 1348
&
Heat pump
18kW
80%
25,920kWh
330% (SPF 3.3)
7855kWh
7855kWh (power)
0.14 perkWh (HP)
1100
* Average value
Example: Heating system with 55C maximum flow temperature, 1800 full utilisation hours, 18kW heat load of the building. DHW heating by the boiler.
House with 150 m2 and an annual heating energy consumption of approx. 39,000kWh incl. DHW heating (3000kWh).
Heat pumps
Vitocal 160-A
Affordable DHW heating with existing central heating and large cylinder.
5
6
Vitocal 160-A
1
62/63
Domestic ventilation
systems
Vitovent 300-F
Vitovent 300
64/65
VITOVENT 300-F
VITOVENT 300
The Vitovent 300-F and Vitovent 300 domestic ventilation systems create a pleasant,
healthy atmosphere in your room, without wasting energy.
Extract air
section
Domestic ventilation
systems
Vitovent 300-F
Vitovent 300-F
1
7
Vitovent 300-F
Domestic ventilation system with
heatrecovery
3
1 Fan
2
3
4
5
6
7
66/67
Domestic ventilation
systems
Vitovent 300
Vitovent 300
1
4
Vitovent 300
Domestic ventilation system with
heat recovery
1
DC fans
Bypass damper
3 Heat exchanger
4 Air filter
2
68/69
The Vitovent 300 provides a comfortable ambient climate all year round, reduces the
ventilation heat demand and lowers the heating costs.
Specification
Type
Output data
(to EN 14511, B0/W35C, 5 K spread)*
Rated heating output
Cooling capacity
Power consumption
Coefficient of performance e in heating mode
Flow temperature
kW
kW
kW
C
Dimensions
Length
Width
Height
mm
mm
mm
Weight
kg
BW 351.A07
BW 351.A18
BWC 351.A07
7.3
5.8
1.59
4.6
72
18.7
14.8
4.14
4.5
72
7.3
5.8
1.59
4.6
72
845
600
1049
1085
780
1267
845
600
1049
135
322
145
BW 351.A07
BW 351.A18
BWC 351.A07
10.3
8.7
1.70
6.1
72
25.7
21.4
4.6
5.6
72
10.3
8.7
1.70
6.1
72
845
600
1049
1085
780
1267
845
600
1049
135
322
145
Type
Output data
(to EN 14511, W10/W35C, 5 K spread)**
Rated heating output
Cooling capacity
Power consumption
Coefficient of performance e in heating mode
Flow temperature
kW
kW
kW
C
Dimensions
Length
Width
Height
mm
mm
mm
Weight
kg
* Brine/water heat pump with conversion kit (accessory) to convert to water/water heat pump
** In conjunction with a high efficiency pump
Type
Output data
(to EN 14511, B0/W35C, 5 K spread)*
Rated heating output
Cooling capacity
Power consumption
Coefficient of performance e in heating mode
Flow temperature
kW
kW
kW
C
Dimensions
Length
Width
Height
mm
mm
mm
Weight
kg
BWS 351.A07
BWS 351.A18
7.3
5.8
1.59
4.6
72
18.7
14.8
4.14
4.5
72
845
600
1049
1085
780
1267
135
322
70/71
Type
BWT 341.A06
BWT 341.A08
BWT 341.A10
5.9
4.7
1.25
4.7
7.9
6.3
1.66
4.7
10.3
8.3
2.19
4.7
kW
kW
kW
Dimensions
Length x width x height
mm
Cylinder capacity
litres
220
1.5
1.5
1.6
260
260
266
BWT 331.A06
BWT_NC 331.A06
BWT 331.A08
BWT_NC 331.A08
BWT 331.A10
BWT_NC 331.A10
5.9
4.7
1.25
4.7
7.9
6.3
1.66
4.7
10.3
8.3
2.19
4.7
N L performance factor
Weight
kg
220
Type
Type
kW
kW
kW
Dimensions
Length x width x height
mm
Cylinder capacity
litres
N L performance factor
Weight
kg
170
1.1
170
1.3
249
249
256
Specification
Type
Type
kW
kW
kW
C
BW 301.A06 BW 301.A08
BW 301.A10
BW 301.A13
BW 301.A17
BWC 301.A06 BWC 301.A08 BWC 301.A10 BWC 301.A13 BWC 301.A17
5.9
4.7
1.3
4.6
60
7.8
6.2
1.65
4.7
60
113
123
117
127
mm
kg
kg
10.0
8.0
2.0
4.8
60
12.9
10.5
2.6
4.9
60
17.0
13.7
3.6
4.7
60
135
145
148
158
Type
Type
kW
kW
kW
C
BW 301.A06 BW 301.A08
BW 301.A10
BW 301.A13
BW 301.A17
BWC 301.A06 BWC 301.A08 BWC 301.A10 BWC 301.A13 BWC 301.A17
7.9
6.7
1.25
6.3
60
10.4
8.8
1.64
6.3
60
113
123
117
127
mm
kg
kg
13.4
11.4
2.1
6.3
60
17.1
14.6
2.8
6.2
60
23.0
19.5
3.7
6.2
60
135
145
148
158
* Brine/water heat pump with conversion kit (accessory) to convert to water/water heat pump
** In conjunction with a high efficiency pump
Type
Output data
(to EN 14511, B0/W35C, 5 K spread)*
Rated heating output
Cooling capacity
Power consumption
Coefficient of performance e in heating mode
Flow temperature
kW
kW
kW
C
Dimensions
Length x width x height
mm
Weight
kg
BWS 301.A06 BWS 301.A08 BWS 301.A10 BWS 301.A13 BWS 301.A17
5.9
4.7
1.3
4.6
60
7.8
6.2
1.65
4.7
60
10.0
8.0
2.0
4.8
60
12.9
10.5
2.6
4.9
60
17.0
13.7
3.6
4.7
60
130
143
112
124
72/73
Type
Output data
(to EN 14511, B0/W35C, 5 K spread)
Rated heating output
Cooling capacity
Power consumption
Coefficient of performance e in heating mode
Flow temperature
kW
kW
kW
C
Dimensions
Length x width x height
mm
Weight
kg
BW 301.A21
BW 301.A29
BW 301.A45
21.2
17.0
4.5
4.7
60
28.8
23.3
6.0
4.8
60
42.8
34.2
9.3
4.6
60
305
345
BW 301.A21
BW 301.A29
BW 301.A45
28.1
23.7
4.7
5.9
60
37.1
31.4
6.2
6
60
58.9
48.9
10.7
5.5
60
Type
Output data
(to EN 14511, W10/W35C, 5 K spread)
Rated heating output
Cooling capacity
Power consumption
Coefficient of performance e in heating mode
Flow temperature
kW
kW
kW
C
Dimensions
Length x width x height
mm
Weight
kg
305
345
BWS 301.A21
BWS 301.A29
BWS 301.A45
21.2
17.0
4.5
5.9
60
28.8
23.3
6.0
6
60
42.8
34.2
9.3
5.5
60
* Brine/water heat pump with conversion kit (accessory) to convert to water/water heat pump
Type
Output data
(to EN 14511, B0/W35C, 5 K spread)
Rated heating output
Cooling capacity
Power consumption
Coefficient of performance e in heating mode
Flow temperature
kW
kW
kW
C
Dimensions
Length x width x height
mm
Weight
kg
300
340
Specification
BW 190
BW 1120
BW 2150
BW 2180
BW 2250
kW
kW
kW
93
74.5
19.5
4.77
121
96.4
24.8
4.83
150
120.1
31.9
4.7
182
145.4
39.6
4.6
240
191.4
50.4
4.76
Dimensions
Length
Width
Height
mm
mm
mm
880
1280
1560
880
1280
1560
880
1920
1560
880
2520
1560
880
2520
1560
Weight
kg
720
820
1180
1240
1360
Number of compressors
pce
WW 1125
WW 1155
WW 2200
WW 2250
WW 2300
kW
kW
kW
122
103
20,9
5.84
145
122
24,6
5.89
190
159
32,1
5.92
240
199
42,1
5.7
290
244
49,5
5.86
Dimensions
Length
Width
Height
mm
mm
mm
880
1280
1560
880
1280
1560
880
1920
1560
880
2520
1560
880
2520
1560
Weight
kg
720
820
1180
1240
1360
Number of compressors
pce
Output data
(to EN 14511, B0/W35C, 5 K spread)
Rated heating output
Cooling capacity
Power consumption
Coefficient of performance e in heating mode
Type
Type
74/75
Type
kW
kW
kW
Dimensions
Length x width x height
mm
Cylinder capacity
litres
BWT 241.A06
BWT 241.A08
BWT 241.A10
5.9
4.6
1.40
4.2
7.7
6.0
1.84
4.2
10.0
7.8
2.32
4.3
220
1.5
1.5
1.6
260
260
266
BWT 221.A06
BWT 221.A08
BWT 221.A10
5.9
4.6
1.40
4.2
7.7
6.0
1.84
4.2
10.0
7.8
2.32
4.3
N L performance factor
Weight
kg
220
Type
kW
kW
kW
Dimensions
Length x width x height
mm
Cylinder capacity
litres
N L performance factor
Weight
kg
170
170
1.1
170
1.3
250
250
256
Type
Output data
(to EN 14511, B0/W35C)
Rated heating output
Cooling capacity
Power consumption
COP e in heating mode
Flow temperature
kW
kW
kW
C
Dimensions
Length x width x height
mm
Weight
kg
BWC 201.A10
BWC 201.A13
BWC 201.A17
5.8
4.5
1.3
4.3
60
7.6
6.0
1.74
4.4
60
9.7
7.7
2.2
4.4
60
13.0
10.3
2.85
4.5
60
17.2
13.7
3.81
4.5
60
119
124
141
154
Specification
kW
Dimensions
Length x width x height
mm
kg
25
kg
28
mm
Weight
kg
76/77
Type
kW
kW
AWHI 351.A10
AWHI 351.A14
AWHI 351.A20
14.5
4.2
3.5
65
18.5
5.8
3.2
65
10.6
3.0
3.6
65
Dimensions
Length (depth)
Width
Height
mm
mm
mm
946
880
1870
946
1030
1870
946
1200
1870
Weight
kg
287
297
361
AWHO 351.A10
AWHO 351.A14
AWHO 351.A20
10.6
3.0
3.6
65
14.5
4.2
3.5
65
18.5
5.8
3.2
65
1265
1380
1885
1265
1530
1885
1265
1700
1885
400
Type
kW
kW
C
Dimensions
Length (depth)
Width
Height
mm
mm
mm
Weight
kg
325
335
Type
AWCI_AC 301.A
Internal installation
AWO-AC 301.A
External installation
AWO-AC 301.A
External installation
(silent version)
kW
3.0 9.0
2.3
3.9
4.4
8.6
3.0 9.0
2.3
3.9
4.4
8.6
3.0 9.0
2.3
3.9
4.4
8.6
Dimensions
Length x width x height
mm
Weight
kg
289
279
309
Output data
(to EN 14511, A2/W35C)
Rated heating output
Power consumption
Coefficient of performance e in heating mode
Coefficient of performance e A7/W35C
Cooling capacity A27/W7C
kW
kW
Specification
Vitocal 242-S
Type
kW
kW
Cylinder capacity
kW
kW
AWT-AC 241.A04
AWT-AC 241.A07
AWT-AC 241.A10
AWT-AC 241.A13
3.0
3.27
1.1 3.8
5.6
3.24
1.3 7.7
7.7
3.5
4.4 9.9
10.6
3.26
5.0 11.9
3.2
2.96
1.2 3.8
6.2
2.6
1.6 8.0
7.4
2.75
2.4 8.5
9.1
2.50
2.4 10.0
220
220
220
220
mm
mm
mm
mm
290
869
610
340
1040
865
340
900
1255
340
900
1255
Weight
Internal unit
External unit
kg
kg
204
43
204
66
207
110
207
110
AWT-AC 221.A04
AWT-AC 221.A07
AWT-AC 221.A10
AWT-AC 221.A13
3.0
3.27
1.1 3.8
5.6
3.24
1.3 7.7
7.7
3.5
4.4 9.9
10.6
3.26
5.0 11.9
3.2
2.96
1.2 3.8
6.2
2.6
1.6 8.0
7.4
2.75
2.4 8.5
9.1
2.50
2.4 10.0
170
170
170
170
Vitocal 222-S
Type
kW
kW
Cylinder capacity
kW
kW
mm
mm
mm
290
869
610
340
1040
865
340
900
1255
340
900
1255
Weight
Internal unit
External unit
kg
kg
194
43
194
66
197
110
197
110
Vitocal 200-S
Type
AWB 201.B04
AWB-AC 201.B04
AWB 201.B07
AWB-AC 201.B07
AWB 201.B10
AWB-AC 201.B10
AWB 201.B13
AWB-AC 201.B13
3.0
3.27
1.1 3.8
5.6
3.24
1.3 7.7
7.7
3.5
4.4 9.9
10.6
3.26
5.0 11.9
3.2
2.96
1.2 3.8
6.2
2.6
1.6 8.0
7.4
2.75
2.4 8.5
9.1
2.50
2.4 10.0
mm
Type
kW
kW
kW
kW
mm
mm
mm
Weight
External unit
Internal unit AWB
Internal unit AWB-AC
kg
kg
kg
mm
340
1040
865
340
900
1255
340
900
1255
43
34
38
66
34
38
110
37
42
110
37
42
78/79
kW
1.5
Power consumption
kW
0.43
3.56
m3 /h
250
kW
1.50
Cylinder capacity
litres
kg
Dimensions
Length x width x height (recirculation air mode)
Height (extract air mode)
mm
mm
285
105/110
660 x 700 x 1846
1838
m3 /h
m3 /h
m3 /h/Pa
mm
Weight
kg
80
Filter class
Filter class
F7
G4
97
Vitovent 300
m3 /h
m3 /h
m3 /h/Pa
285
80 285
280/170
680 x 400 x 1468
180
300
400
50 to 180
180/150
50 to 300
300/100
50 to 400
400/100
mm
Weight
kg
25
31
32
Filter class
Filter class
F6
G4
F6
G4
F6
G4
92
91
91
Automatic bypass
No
Yes
Yes
Summer cassette
Yes
No
No
Yes
Yes
Yes
80/81
System technology
Control convenience
Clear, convenient,
intelligent the Vitotronic
offers you perfect
functionality for fast and
precise control over your
heating system.
Page 84
Data communication
Do you know about
Vitocom?
It is the ideal solution for
controlling the heat pump
system remotely, and
exchanging data easily
and conveniently from a
different location.
Page 86
System technology
82/83
hygienestandards.
System technology
Control convenience
84/85
System technology
Data communication
86/87
Vitotrol app
The Vitotrol app for controlling heating
systems is available for iPhone, iPad and iPod
touch. To enable this, the Vitotronic must be
extended by the Vitocom 100 LAN interface
and must be connected to the DSL router
on site. A configuration of the DSL router
is not required. Heat pump messages are
sent to the iPhone. The Vitotrol app allows
you to control up to three heating circuits,
making it a convenient tool for operating your
heatingsystem.
Vitocom 100
Vitocom 100 is the easy way to remotely
monitor and control the heat pump via your
mobile phone and is ideal for detached and
two-family houses. It's also suitable for
holiday and weekend homes that are not
occupied all the time. On your way, start up
the heat pump via your mobile phone, so
you can arrive in a cosily warm home, just as
you like it. It could hardly be any simpler or
moreeconomical.
Vitocom 200 and Vitodata 100
If you want to combine the highest levels of
convenience and security, the Vitocom 200 is
the right solution. This attractively priced version
offers ideal conditions for comprehensive data
communication perfect for private homes
and smaller commercial buildings, such as
workshops or clinics. A standard PC or laptop
are required.
88/89
Accessories
Universal radiators
The quality of radiators is characterised
by the high grade, long lasting paint finish.
Thanks to their neutral finish in white
RAL9016, Viessmann universal radiators
will suit the decor of any room. On request,
all universal radiators can also be supplied in
specialcolours.
Panel radiators
Their brilliant, smooth design makes
these flat panel radiators an exceptionally
aesthetic design feature, which is subtle
yet effective. The technical concept behind
them is optimised for the demands of energy
efficient heating. The resistant, plastic-coated
surface is easy to clean and gleams in white
RAL9016.
Bathroom radiators
These innovative Vitoset bathroom radiators
with their slender pipe elements look elegant
and light. They will help you to make your
bathroom stylish, and will keep your towels
nice and warm. Alongside their connection
90/91
Contacts and
further information
Viessmann online
A great deal of further information on
Viessmann products and services can be
found at www.viessmann.de.
92/93
www.viessmann.de
Quick help via the internet
Do you have questions about Viessmann
products or on the subject of heating?
At www.viessmann.de, you can find
comprehensive information round the clock
on all Viessmann heating systems and their
output levels, a technical glossary, an energy
savings check and much more.
Subsidy programmes
For current information regarding subsidies for
environmentally responsible heating systems
from Viessmann, visit www.viessmann.de.
Of course, individual and competent advice
can also be obtained from all Viessmann
sales offices or directly from your
heatingcontractor.
Solar thermal
systems and
photovoltaics
Detached houses
Apartment buildings
Commerce / Industry
94/95
Wood combustion
technology, CHP and
biogas production
up to 50 MW
Air conditioning
technology
Heating system
accessories
up to 2 MW
Detached houses
Apartment buildings
Commerce / Industry
China
France
Porsche Leipzig,
Germany
Regensburg, Germany
Germany
Belgium
Heliotrop Freiburg,
HafenCity, Hamburg,
Germany
Germany
Sweden
Dubai
Congressional Centre,
Germany
Italy
Brunstad, Norway
Germany
Germany
Germany
Switzerland
Oil boilers
Gas boilers
Solar thermal
systems and
photovoltaics
Wood combustion
technology, CHP, and
biogas production
96/97
The company
98/99
Deutschlands nachhaltigste
Produktion 2009
Deutschlands nachhaltigste
Marke 2011
Viessmann Group
Company details
Established in: 1917
Employees: 9600
Group turnover: 1.86 billion
Export share: 55 percent
24 manufacturing plants in 11 countries
Sales companies and representations
in 74 countries
120 sales outlets worldwide