ATER COOLING SYSTEM

WA
T a p C O O L DOMESTIC W
High ambient together with solar gains cause excessively high temperatures within the
roof level water storage tank during summer season and it results in unacceptably high tap
water supply temperatures .
TapCOOLunit offers a simple, reliable and cost effective solution to overcome this problem.
It offers a new way of providing refreshing Cool Water on demand without the need for
expensive and inefficient continous cooling methods.

Overhea te d
Wate r
6 0 oC

Overhea t e d
Wat e r Main

F E A T U R E S ;

TapCOOL Domestic Water Cooling is based on a relatively small thermal energy storage
volume which can be generated during overnight using lower ambient and electricity prices
to store sufficient energy for use during day peak periods.
Factory finished unit consists of an ice storage vessel comprising ice heat exchanger
surface, refrigeration unit, water heat exchanger and associated circulation pump complete
with a central control panel for fully automated operation.

Wat er
Distribut ion
Pipework

Cold Water
20 oC

COILS
Refrigeration coils are submerged
within the insulated double skin tank in
order to provide the cooling production
and storage facility.

HEAT EXCHANGER
A combination of plate heat exchanger
and pump arrangement provides fast
and efficient response as soon as the
leaving water temperature exceeds a
pre-set level.
It is only operational if the water is
drawn and therefore this concept
offers unmatched energy efficiency
and fast response.

WEATHER HOUSING
TapCOOL can be either installed outside
at roof floor or alternatively inside the roof
void.
Optional weather housing protects the
refrigeration unit, control panel and
electrical components for a safe and
reliable operation.
Water tank can be installed within the loft
area and the associated refrigeration unit
can be installed outside in a similar
fashion to the split units.

REFRIGERATION

Fully packaged Air cooled condensing unit


provides the refrigeration for the cooling coils.
It can be supplied in any refrigerant option and it
is fully integrated as part of the control.
It is designed to run mainly overnight to utilise
lower ambient and electricity rates.

CONNECTIONS
TapCOOL only requires a single phase power supply
and the water intake from the water storage tank
enters the unit at high temperature and leaves at a
pre-set adjustable leaving temperature.

CONTROLS
A digital thermostat controls the unit water leaving temperature
at a pre-set user adjustable temperature.
The control over the energy storage and the essential safety
components are incorporated for fully functional kit ready to
operate.

BENEFITS:
REDUCED RUNNING COST
It runs shorter periods and it is only operated whenever
required to satisfy the demand, hence, it eliminates the
need for a large water tank cooling load.
QUICK & STEADY RESPONSE
Ice offers unmatched heat transfer efficiency. Hence, large
peak loads can be handled without effecting the water
supply temperatures.
LOWER MAINTENANCE COST
Totally sealed and factory finished units minimise the
maintenance requirement.

Patent Pending: GB 9826453.4

FLEXIBLE SYSTEM
Multiple units can be connected either in parallel or series
arrangements to satisfy any load and system requirements.
EASY INSTALLATION
Fully packaged product requires only a single phase power
supply and water connections.
GREEN SOLUTION
Use of Environmentally Friendly refrigerants and reduced
refrigeration machinery leads to reduced refrigerant volume.

TECHNICAL SUPPOR
T
SUPPORT
EPS offers full system design support to assist in proper selection
and integration into existing or new installations as part of our
customer commitment. Please consult our technical sales team at
sales@epsltd.co.ukfor your specific application or visit our web site
www.epsltd.co.uk..

Unit 32, Mere View Industrial


Estate, Yaxley, Cambridgeshire,
PE7 3HS, UNITED KINGDOM
Tel. :+44-(0)1733-243400
Fax.:+44-(0)1733-243344

TapCOOL
Design Data

D
E

A
D ime ns ions

Wate r C onn ections

Weig ht (k g)

Su pply (1)

A (mm) B (mm)

C (mm)

(D ) In let

(E) Out let

S h ipp in g

W orkin g

17 00 11 50

5 40

DN 25

DN 25

1 50

6 50

Po w e r (5)

Startin g

R unn in g

( kW)

C u rr e nt (A m ps)

C u rr e nt (A m ps)

1. 9

45

9. 1

23 0V /1Ph / 50 H z

No te s;

1)
2)
3)
4)
5)

Oth e r p ow e r sup p lie s ( 1 1 0 V / 1 P h / 60 Hz ) a v ailab le o n re q ue s t.


S ta nd ard un it sup p lie d w ith R 2 2 r e fr ig e ra nt a nd o th e r re f rig e r an ts a v ailab le o n re q ue s t.
S ta nd ard un it fo r a n av e rag e f am ily ho m e b ut la rg e r u nit c an b e su p p lie d to m a tc h the larg e r lo a d s.
Un it f u lly f a cto ry f inis h e d and r e a d y t o o p e ra te .
D e s ig n d ata is b as e d o n 3 8 D e g C am b ie nt. 4 3 D e g C a m b ie n t p o we r c o n sum p tio n inc re a s e s to 2 .1 kW .

Application Data
11.00
60

10.00
9.00

Temperature Difference (C)

Minimum required head (m)

50

8.00
7.00
6.00
5.00
4.00

40

30

20

3.00
2.00
10

1.00
0.00

10

20

30

40

50

60

10

20

30

38.00

110

36.00

105

60

95

32.00

90

30.00

85

28.00

80

26.00

75
Temperature Difference (F)

Minimum required head (ft)

50

100

34.00

24.00
22.00
20.00
18.00
16.00
14.00

70
65
60
55
50
45
40

12.00

35

10.00

30

8.00

25

6.00

20
15

4.00

10

2.00
0.00
0.00

40

F lo w R ate (lt/m in )

Flow Rate (lt/min)

5
0

1.00

2.00

3.00

4.00

5.00

6.00

7.00

8.00

9.00

10.00

11.00

12.00

13.00

14.00

0.00

1.00

2.00

3.00

4.00

5.00

6.00

7.00

8.00

9.00

10.00

11.00

12.00

13.00

F lo w R ate (g p m )

Flow Rate (gpm)

TECHNICAL SUPPOR
T
SUPPORT
TapCOOL standard unit is designed to handle an average family domestic water cooling
requirement. EPS also offers full range of custom-made units for larger capacities as
well as industrial and food processing applications.
For your specific application please consult our sales team.