Escolar Documentos
Profissional Documentos
Cultura Documentos
for
ERS-APPLICATION
GENERAL INFORMATION
KELSOP Information
1 of 7
KELSOP Information
2 of 7
Wind pressure on
construction
Wind pressure on
conductors
Temperatures
Mechanical properties
(tension&temp.)
KELSOP Information
3 of 7
Line angle
The TOWER
CONSTRUCTION DATA
SCREEN
Determination of tower
characteristics and
configurations.
The towerconfiguration drawing
will be produced in real time.
KELSOP Information
4 of 7
After inputing all data (or adjustment of the defaults), KELSOP calculates all relevant loads and forces,
checks these values with the admissible strength and approves (or disapproves) the application of the
ERS.
KELSOP also provides worksheets to be used by field-engineers during the realisation of the ERS
The KELSOP program enables manager and field-engineer to apply the ERS in a safe way.
KELSOP Information
5 of 7
4
5
8
9
-2-
altitude = 0 m
DE
SC1
SC2
DC
RA1
RA2
AT1
AT2
DE
180,00
184,00
176,00
169,00
201,00
90,00
183,00
240,00
180,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
170,00
295,00
238,00
221,00
130,00
145,00
238,00
192,00
1629,00
1629,00
KELSOP Information
-3-
6 of 7
Towers
1-2
2-3
3-4
4-5
5-6
6-7
7-8
8-9
170,00
295,00
238,00
221,00
130,00
145,00
238,00
192,00
223,90
223,90
223,90
223,90
223,90
223,90
238,00
192,00
T [C]
Tension [kN]
Tension [kN]
Tension [kN]
20
21,60
2,25
6,79
4,42
3,81
1,32
1,64
21,46
4,45
22,01
2,82
25
20,77
2,34
7,06
4,59
3,96
1,37
1,71
20,70
4,61
20,96
2,96
30
20,00
2,43
7,33
4,77
4,11
1,42
1,77
20,00
4,77
20,00
3,10
35
19,29
2,52
7,60
4,95
4,26
1,48
1,84
19,35
4,93
19,12
3,25
40
18,64
2,61
7,87
5,12
4,41
1,53
1,90
18,75
5,09
18,33
3,39
45
18,03
2,70
8,13
5,29
4,56
1,58
1,96
18,19
5,25
17,60
3,53
50
17,48
2,79
8,39
5,46
4,71
1,63
2,03
17,67
5,40
16,93
3,67
55
16,96
2,87
8,65
5,63
4,85
1,68
2,09
17,19
5,55
16,32
3,80
60
16,47
2,96
8,90
5,79
5,00
1,73
2,15
16,74
5,70
15,76
3,94
65
16,02
3,04
9,15
5,96
5,14
1,78
2,21
16,32
5,85
15,25
4,07
70
15,60
3,12
9,40
6,12
5,27
1,82
2,27
15,92
6,00
14,77
4,21
75
15,21
3,20
9,64
6,27
5,41
1,87
2,33
15,55
6,14
14,33
4,33
28,03
2,76
8,31
5,41
4,66
1,61
2,01
28,30
5,36
27,32
3,61
30 + wind
-4-
item
result
limit
conclusion
Ma [kNm]
0,00
235,53
Approved
Mb [kNm]
54,65
235,53
Approved
Mc [kNm]
16,73
235,53
Approved
Md [kNm]
38,07
235,53
Approved
Fd [kN]
142,12
491,39
Approved
Ra [kN]
5,30
TiTrk [kN]
56,06
240,00
Approved
Fg1 [kN]
86,19
120,00
Approved
Fg2 [kN]
39,26
120,00
Approved
Fg3 [kN]
93,36
120,00
Approved
Fg4 [kN]
25,06
120,00
Approved
Fg5 [kN]
25,06
120,00
Approved
Fg6 [kN]
18,82
120,00
Approved
legend
M
Fd
Fg
R
TiTrk
torque
vertical resultant force
guy wire tension
reaction force
force in tension insulator
-6-
KELSOP Information
7 of 7