Você está na página 1de 12

DIgSILENT PowerFactory

Functions

PowerFactory: Functions

Load Flow/Transmission
Fast and Accurate Load Flow Algorithm (Full Newton Raphson,
Newton-Raphson Current Iteration)
AC and DC Networks (for HVDC Transmission)
Secondary Power-Frequency Control
Primary Control
Secondary Reactive Power-Voltage Control
Load Profiling
P-V Curves
All Types of Sensitivities (dv/dQ, dphi/dP, Branch Sensitivities etc.)
Modal dv/dQ Analysis

PowerFactory: Functions

Load Flow/Distribution
Any Type of Network Technology:
Three-Phase,Three-Phase-Four Wire, Two-Phase, Bi-Phase,
Single Wire-Earth Return, DC Networks
Any Type of Network Topology (Meshed and Radial)
Suited for Extremely Large MV Networks (>20000 Bus Bars)
Voltage Profile Diagrams
Stochastic Load Models for Considering Load Diversity in LV
Networks
One- and Two-Dimensional Load Profiles
Feeder Scaling
Open Point Optimization

PowerFactory: Functions

Active and Reactive Power


Dispatch
Loss Minimization
Fuel Cost Minimization
Branch Flow Limits
Bus Bar Voltage Limits
Active/Reactive Power Limits
Stator Current Limits
Reserve Constraints

PowerFactory: Functions

Short Circuit
Short Circuits According to IEC 60909, ANSI C37 and Complete
Superposition Method
Full Implementation of IEC 60909/2001
Multiple Faults Analysis
Fault Types:
Three-Phase
Two-Phase
Two-Phase to Ground
Single-Phase to Ground
Inter-Circuit (also Between Different Voltage Levels)
Open Conductor
Sliding Faults along Lines

PowerFactory: Functions

Stability
Transient and Dynamic
Stability
Highly Accurate Generator
and Load Models

Simulates
Any Unbalanced Fault Scenario

Large Library of Standard


Models
User Defined Modeling
Variable Step Size Algorithm
Easy-to-Use Chart Definition
Interactive Event Definition
Small Signal Analysis (Modal
Analysis)
PowerFactory: Functions

Electromagnetic Transients
Detailed Network Model
Transformer Saturation
Transformer Capacitances
Distributed Parameter Line
Models (Constant and
Frequency Dependent)
Detailed (Switching) Power
Electronics Device Models
Easy-to-Use Chart Definition
Interactive Event Definition
Variable Step Size Algorithm
PowerFactory: Functions

Overcurrent Protection
Modeling
CT and VT Models
Fuses
OCT-Relays
Directional Relays
Differential Relays
LV Circuit Breakers
Coordination
Selectivity Diagrams
Simulation
Steady State
Time Domain
PowerFactory: Functions

Distance Protection
Modeling
CT and VT Models
MHO-Characteristics
Quadrilateral Characteristics
X/R-Blinder
Starting Characteristics
Inter-Tripping Schemes
Coordination
R-X Diagrams
Time-Distance Diagrams
Simulation
Steady State
Time Domain
PowerFactory: Functions

Harmonics
Balanced and Unbalanced Harmonic Sources
Characteristic, Non-Characteristic and Inter-Harmonics
Frequency- and Time-Domain Charts
Harmonic Loadflow
Frequency Scan
Frequency Dependent Line
Parameters
Distributed Parameter
Line Models
Filter Sizing

PowerFactory: Functions

10

Reliability
Weibul-Markov Failure Models
Line/Transformer/Bus Bar Failures
Common Mode Failures
Double Earth Faults
Circuit Breaker Failures
Protection Failures
Analytical State Enumeration
Monte Carlo Simulation
Advanced System Restoration Models including Generator
Dispatch and Load Shedding

PowerFactory: Functions

11

DPL (DIgSILENT Programming


Language)
Arithmetic operations, standard functions
Virtual object functions
Logic operations, lLoops: do{..} while()
Alternative: if(.) then{.} else{}
Access to any system parameter
Use of every command
Every command can be used
Definition of result files, creation of plots

PowerFactory: Functions

12

Você também pode gostar