Escolar Documentos
Profissional Documentos
Cultura Documentos
Starter Type:
Circuit Breaker:
Contactor:
Overload Relay:
Rated Operational Voltage:
Test voltage:
Rated Conditional S.C. Current (Iq):
Level of S.C. Coordination:
Motor Ratings
Rated
Operational
Current Ie
[kW]
[A] 1)
Contactor
Magnetic
Trip Current
[A]
Catalog
Number
3)
S.C. Coordination
Test
Coordination Summary
Type
Letter
Remark
0.06
0.20
140M-C2N-B10
13
100-C09...
193-EEAB
0.1 - 0.5
---
0.09
0.30
140M-C2N-B10
13
100-C09...
193-EEAB
0.1 - 0.5
---
0.12
0.44
140M-C2N-B10
13
100-C09...
193-EEAB
0.1 - 0.5
193-EC1PB
0.4 - 2
---
0.18
0.60
140M-C2N-B10
13
100-C09...
193-EEBB
0.2 - 1.0
193-EC1PB
0.4 - 2
---
0.25
0.85
140M-C2N-B10
13
100-C09...
193-EEBB
0.2 - 1.0
193-EC1PB
0.4 - 2
---
0.37
1.1
140M-C2N-B16
20
100-C09...
193-EECB
1.0 - 5.0
193-EC1AB
1-5
---
0.55
1.5
140M-C2N-B16
20
100-C09...
193-EECB
1.0 - 5.0
193-EC1AB
1-5
---
0.75
1.9
140M-C2N-B25
32
100-C09...
193-EECB
1.0 - 5.0
193-EC1AB
1-5
---
1.1
2.7
140M-D8N-B40
52
100-C09...
193-EECB
1.0 - 5.0
193-EC1AB
1-5
1.5
3.6
140M-D8N-B40
52
100-C09...
193-EECB
1.0 - 5.0
193-EC1AB
1-5
2.2
4.9
140M-D8N-B63
82
100-C09...
193-EEDB
3.2 - 16
193-EC1BB
3 - 15
---
6.5
140M-D8N-C10
130
100-C09...
193-EEDB
3.2 - 16
193-EC1BB
3 - 15
---
8.5
140M-D8N-C10
130
100-C09...
193-EEDB
3.2 - 16
193-EC1BB
3 - 15
---
5.5
11.5
140M-D8N-C16
208
100-C12...
193-EEDB
3.2 - 16
193-EC1BB
3 - 15
---
7.5
15.5
140M-D8N-C16
208
100-C16...
193-EEDB
3.2 - 16
193-EC1CB
5 - 25
---
11
22
140M-D8N-C25
325
100-C23...
193-EEEB
5.4 - 27
193-EC1CB
5 - 25
---
15
29
140M-D8N-C32
448
100-C30...
193-EEFD
9 - 45
193-EC1DD
9 - 45
---
18.5
35
140M-F8N-C45
585
100-C37...
193-EEFD
9 - 45
193-EC1DD
9 - 45
---
22
41
140M-F8N-C45
585
100-C43...
193-EEFD
9 - 45
193-EC1DD
9 - 45
---
30
55
140MG-G8P-D12
375 - 1,375
100-C60...
193-EEGE
18 - 90
193-EC1EE
18 - 90
---
37
66
140MG-G8P-D12
375 - 1,375
100-C72...
193-EEGE
18 - 90
193-EC1EE
18 - 90
45
80
140MG-G8P-D12
375 - 1,375
100-C85...
193-EEGE
18 - 90
193-EC1EE
18 - 90
55
97
140MG-G8P-D12
375 - 1,375
100-C97...
193-EEVE
60 - 120
63
113
140MG-J8P-D25
1,250 - 2,500
100-D115...
193-EEHF
30 - 150
193-EC1FF
28 - 140
75
132
140MG-J8P-D25
1,250 - 2,500
100-D140...
193-EEJF
40 - 200
193-EC1GF
42 - 210
90
160
140MG-J8P-D25
1,250 - 2,500
100-D180...
193-EEJF
40 - 200
193-EC1GF
42 - 210
---
110
195
140MG-K8P-D40
400 - 4,000
100-D210...
193-EEJG
40 - 200
193-EC1GG
42 - 210
---
132
230
140MG-K8P-D40
400 - 4,000
100-D250...
193-EEKG
60 - 300
193-EC1HG
60 - 302
160
280
140MG-K8P-D40
400 - 4,000
100-D300...
193-EEKG
60 - 300
193-EC1HG
60 - 302
200
350
140MG-K8P-D40
400 - 4,000
100-D420...
193-EELG
100 - 500
193-EC1JG
84 - 420
---
250
430
140MG-M8P-D80
800 - 8,000
100-D630
193-EEMH
120 - 600
193-EC1KH
125 - 630
---
315
540
140MG-M8P-D80
800 - 8,000
100-D630
193-EEMH
120 - 600
193-EC1KH
125 - 630
355
610
140MG-M8P-D80
800 - 8,000
100-D630
193-EENH
160 - 800
193-EC1KH
125 - 630
400
690
140MG-M8P-D80
800 - 8,000
100-D860
193-EENH
160 - 800
193-EC1LH
172 - 860
450
770
140MG-M8P-D80
800 - 8,000
100-D860
193-EENH
160 - 800
193-EC1LH
172 - 860
---
500
850
140MG-M8P-D80
800 - 8,000
100-D860
193-EC1LH
172 - 860
---
--Type "2"
Type "2"
2)
140MG "Max" circuit breaker size, lower current rating devices can be used. 140MG-G Frame can be replaced with the 140MG-H Frame
3)
4)
Overload relay 193-ED with the same current setting range may also be used (up to 45A)
5)
Overload relays 193-EC2 (up to 90 A), EC3, EC5 or E300 with the same current range may also be used
400V_3C_MCP_E_65kA
-------
Type "2"
Type "2"
TS-1037-1M
TS-1037-1M
---
-----
--Type "2"
Note: This data is subject to change by Rockwell Automation without notice. Go to www.rockwellautomation.com/go/globalsccr for latest information.
SCCR-1000A 040314 PH
TS-1037-1M
---
---
Heavy Duty Starting and High Inrush motors may require oversizing of circuit breaker and/or contactor
1)
TS-1000-1A
TS-1037-1M
-----