Você está na página 1de 64

Committed to Excellence!

Cable Glands & Circular Connectors for


Hazardous/Increased Safety Locations
Our Service makes the difference!

Armored Solutions
Exd / Ex -e A p p r ove d
Ex -d/

N
Am or th
e
Ap p ric an
ro
vals
!

Non-Armored Solutions
E x - d A p p r ove d

Hi/Low Temperature &


Chemical Resistant
(Stainless Steel / Nickel Plated Brass)

E x - e A p p r ove d

E x - i A p p r ove d

Intrinsically Safe (IS)

Standard / Multi-Hole / IS / Clamping

(Nickel Plated Brass / 316L Stainless Steel)

(Nylon / Nickel Plated Brass / 303 & 316L Stainless Steel)

UL746C
f1
C

US

GL

ATEX

Committed To Excellence!

Gost

Setting Standards

Ex-d EXIOS
Cable Glands

Table of Contents
Cable Glands, Conduit & Accessories

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Pg

Pg

Description (Armored)

Introduction - EXIOS (+Standard/+MZ/+Barrier) Cable Gland


EXIOS (UL +Barrier) Cable Glands - NPT/Metric
UL / Ex-d (Flameprood) / Ex-e
6
EXIOS (+Barrier) Cable Glands - NPT/Metric
cUS / ATEX / IECEx / Ex-d (Flameproof) / Ex-e
7
Assembly Instructions - EXIOS (+Barrier / UL +Barrier)
8-9
EXIOS (+Standard/+MZ) Cable Glands - NPT/Metric
cUS / ATEX / IECEx / Ex-d / Ex-e
10-11 Overview / Assembly Instructions - EXIOS (+Standard/+MZ)
12
EXIOS (+A2F) Cable Glands - NPT/Metric (Non-Armored)
cUS / ATEX / IECEx / Ex-d / Ex-e

Ex-e
Nylon Glands

3
4-5

Ex-e Multi-Hole &


Romex Glands

Ex-d Nickel Plated Brass/Stainless Steel


Description (Non-Armored)

13
14

Introduction - Nickel Plated Brass / Stainless Steel - Ex-d


Nickel Plated Brass Cable Glands: Low Temp.
ATEX / IECEx / Ex-d - (Nylon/PVDF) Splines - NPT/Metric
Nickel Plated Brass Cable Glands w/ (MZ) Clamp: Low Temp.
ATEX / IECEx / Ex-d - (Nylon) Splines - NPT/Metric
(316L) Stainless Steel Cable Glands: Low Temp.
ATEX / IECEx / Ex-d - (Nylon/PVDF) Splines - NPT/Metric

16

Ex-e Nylon Cable Glands

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Pg

Description (Non-Armored)

Ex-e EMI / RFI Nickel


Plated Brass Glands

17
Introduction - Nylon Cable Glands
18-19 Fiber Reinforced Nylon Black Cable Glands: Metric/NPT
cUS / ATEX / IECEx / Class / Div / EN 60079-0: 2012 / Ex-e
20
Nylon Black/Blue Cable Glands: Metric/Metric Elongated
UL / CSA / ATEX / IECEx / Inmetro / Ex-e
21
Nylon Black/Blue Cable Glands: PG/PG Elongated
UL / CSA / ATEX / IECEx / Inmetro / Ex-e
22
Nylon Black/Gray/Blue Cable Glands: NPT
UL / CSA / ATEX / IECEx / Inmetro / Ex-e
23-24 Nylon Gray Cable Glands: Metric/PG/PG & Metric Elongated
UL / CSA / ATEX / IECEx / Inmetro / Ex-e
25
Anodized Alumium with (MZ) Clamp Black Nylon:
ATEX / IECEx / Inmetro / Ex-e - NPT/Metric/PG

Ex-e Multi-Hole / Romex Glands


Pg

Description (Non-Armored)

Romex Nylon Black/Gray Cable Glands: NPT/Metric/PG


UL / ATEX / Ex-e / Inmetro
27
Romex Nickel Plated Brass Cable Glands: NPT/Metric/PG
UL / ATEX / IECEx / Ex-e
28-33 Multi-Hole Nylon/Nickel Plated Brass Glands: NPT/Metric/PG
UR / CSA / ATEX / IECEx / Inmetro / Ex-e

Ex-e Conduit &


Fitting Systems

26

Ex-e/Ex-d Clamping (Extra Pull-Out)


Pg

Description (Non-Armored)

15

Nickel Plated Brass Cable Glands with (MZ) Clamp - Low Temp.
ATEX / IECEx / Ex-d - (PVDF) Splines - NPT/Metric
Anodized Alumium with (MZ) Clamp Black Nylon - Metric/PG
ATEX / IECEx / Inmetro / Ex-e
Nickel Plated Brass Cable Glands with (MZ) Clamp
(Nylon/PVDF) Splines - NPT/Metric/PG
UL / UR / CSA / ATEX / IECEx / Ex-e
EMI/RFI (Braided) with (MZ) Clamp: Nickel Plated Brass
Std/Low Temp. - (Nylon/PVDF) Splines - NPT/Metric/PG
CSA / ATEX / IECEx / Ex-e

25
37

44

www.sealconex.com

-60C

Description (Non-Armored)

34
Introduction - Nickel Plated Brass/Stainless Steel - Ex-e
35-36 Nickel Plated Brass Cable Glands: (Nylon) Splines
Std/Low Temp. - NPT/Metric/PG/Elongated
UL / UR / CSA / ATEX / IECEx / Ex-e
37
Nickel Plated Brass Cable Glands with (MZ) Clamp:
(Nylon/PVDF) Splines - NPT/Metric/PG
UL / UR / CSA / ATEX / IECEx / Ex-e
38-39 Nickel Plated Brass Cable Glands:
(PVDF) Splines - NPT / Metric / PG / PG Elongated
UL / UR / CSA / ATEX / IECEx / Ex-e
40
(303) Stainless Steel Cable Glands:
(Nylon/PVDF) Splines - Std/Low Temp. - Metric/PG
UL / UR / CSA / ATEX / IECEx / Ex-e

Ex-e EMI/RFI (Braided/Foil) Shielded

-60C

Pg

15

Ex-e / Ex-d
Accessories

Technical
Information

Ex-e Nickel Plated Brass/Stainless Steel

Ex-e/Ex-d EXIOS Cable Glands

Pg

Description (Non-Armored)
-60C

41-42 EMI/RFI (Braided): Nickel Plated Brass


Std/Low Temp. - ( Nylon/PVDF) Splines - NPT/Metric/PG
CSA / ATEX / IECEx / Ex-e
43
EMI/RFI (Braided/Foil): Nickel Plated Brass
Std/Low Temp. - (Metal Coated Nylon) Spline - Metric/PG
CSA / ATEX / IECEx / Ex-e
44
EMI/RFI (Braided) with (MZ) Clamp: Nickel Plated Brass
Std/Low Temp. - (Nylon/PVDF) Splines - NPT/Metric/PG
CSA / ATEX / IECEx / Ex-e

Ex-e Conduit System


Pg

Description

45
45
45

Corrugated Conduit Snapflex: Nylon - Ex-e


Mounting Brackets Snapclip: Nylon - Ex-e
Snapclic DUO Conduit Fitting: Nickel Plated Brass - Ex-e

Ex-e/Ex-d Accessories
Pg

Description

46
46
47
47
48
48
49
50
51
52
53
53
54
54
54
54

Accessories Overview
Locking Nuts (303) Stainless Steel: Metric/PG
Locking Nuts Nickel Plated Brass: NPT/Metric/PG
Locking Nuts (EMI/RFI) Nickel Plated Brass: Metric/PG
Locking Nuts Nylon: NPT/Metric/PG
Hole Plugs (Mushroom): NPT/Metric/PG - Ex-e
Hex Plugs Nylon/Nickel Plated Brass: Metric/PG - Ex-e
Hex Plugs (303/316L) Stainless Steel: Metric/PG - Ex-e / Ex-d
Thread Reducers: Nickel Plated Brass: Metric/PG- Ex-e
Thread Reducers: Stainless Steel (303): Metric/PG- Ex-e
Thread Reducers: Nickel Plated Brass: Metric - Ex-e / Ex-d
Thread Reducers: (316L) Stainless Steel: Metric - Ex-e
Red Fiber Washers: NPT/Metric
Grounding (Earth) Tag: NPT/Metric
Serrated Washers: NPT/Metric
Shrouds: (for EXIOS Cable Glands) NPT/Metric

Technical Information / Cross Reference


Pg

Description

55
Standard Cable Gland Fittings & Accessories
56
Ex-e/Ex-i Circular Connectors (Signal/Power/RJ45)
57
Standard Sealcon Circular Connectors
57
Marketing Segments
58-61 Technical Information / Disclaimer
62-63 Index / Cross Reference (Sealcon / Hummel)

800-456-9012

Dimensions, specifications and certifications may be changed without prior notice.

Ex-d EXIOS
Cable Glands

EXIOS (+Standard / +MZ / +Barrier ) Cable Glands


Introduction - Ex-d (Flameproof) / Ex-e
Technical Description

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Approvals: UL, CSA, ATEX, IECEx, Inmetro, Gost


Certifications: ABS, German Lloyd, DNV
Silicone O-Ring & Seals: Ideal in Low Temperature Applications!
Temperature Range: -76F to 221F (-60C to +105C) for select products
Captive Interlocking Armor Cone: Safe & Secure Assembly!
Octagon Design keeps torque off cable and armor!
Knurled Grip Profile Provides Quicker Hand Assembly Time!
Fewer Parts with Maximum Grip!
Wider Grip Wrenching Flats Easier Tighten!
(9) Sizes Covering a Larger Cable Range - Requiring Less Inventory!
Easy Part Numbering System Fewer Mistakes!

Ex-e
Nylon Glands

EXIOS (+Standard / +MZ) with


Overlapping Clamping Splines
have Double Compression
Glands on the inner and outer
jacket of the cable.

Your One Stop Solution For All Cable & Wire Accessories!

MZ (Clamp)- Unique
Solution to prevent braid
or armor from sheering
off under excessive cable
torque.

US

ATEX
These Tags are installed
between the cable gland and
equipment to provide grounding.

Shroud, Red Fiber


Washers & Other
Accessories Available

Ex-e Conduit &


Fitting Systems

Grounding (Earth) Tags

Ex-e EMI / RFI Nickel


Plated Brass Glands

US

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Innovative Interlocking Armor


Cone - Safe Assembly!

Ex-e Multi-Hole &


Romex Glands

Zero torsion on cable cores and armor


Halogen-Free & Phosphorous-Free
IP 68 5 bar, EN 60529
Class 1, Div 2,
(cUS), ATEX, IECEx
Class 1, Div 1, UL (YU Gland only)
Zone 1, Zone 2, Zone 20, Zone 21 und Zone 22
Gas Groups IIA, IIB and IIC Apparatus Group III
Equipment Protection Level GbDa

On Page 46 - 54

Ex-e / Ex-d
Accessories

For securing a cable gland


in a knockout hole.

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

www.sealconex.com

Technical
Information

Use of a Serrated Washers


will help reduce the chances
of the cable gland or locking
nuts from loosening under
vibration.

Locking Nuts

Ex-d EXIOS
Cable Glands

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Ex-e
Nylon Glands

UL File: E351373
Class 1, Div 1

For Armored Cable with Compound

Raw Brass/NPB Cable Glands EXIOS UL +Barrier for Hazardous Duty Locations, Nylon Clamping Insert, Silicone O-Ring/Seal, V2, UL94, IP 68 (5 bar)
Part Numbers
Part Numbers
Size
Thread
Dimensions in Inches (mm)
(See Diagram Below)
-13F to 185F
-13F to 185F
Type
Type
Cable
(- 25C to 85C)
(- 25C to 85C)
Cable
Range Dia.
Thread
& Size
Clearance
Range
Inner
Over
Max.
Length
Page 59
Hole
for Thread
Jacket Cond. No.
Armor
H
Specs
+.01 (+.25 mm)
A1
A2
A3 Cond. Range
GL
max
D mm
.35
.63
.47
.35
0
0.05
.79
2.68
1.14
.94
YU13NM-B1
YU13NM-BR
1/2 NPT
20 - 2
.83 (21.1)
10 (0 - 1.25) (20)
(9 - 16)
(12)
(8.8)
(68) (29) (24)
.49 - .81
.55
.45
0 - 0.06
.79
2.87 1.38 1.18
YU13NL-B1
YU13NL-BR
1/2 NPT
20 - 3
.83 (21.1) (12.5
- 20.5) (14) (11.5) 15
(0 - 1.4) (20)
(73) (35) (30)
.67
1.02
.79
.65
0
0.06
.81
3.2 1.65 1.42
YU21NK-B1
YU21NK-BR
3/4 NPT
25
1.05 (26.7) (16.9 - 26)
(20) (16.4) 25
(0 - 1.6) (20.5) (81.3) (42) (36)
.87 - 1.30
1.02
.84
0 - 0.08
.98
3.37 2.05 1.81
YU29NK-B1
YU29NK-BR
1 NPT
32
1.35 (34.3)
(22 - 33)
(26) (21.4) 45
(0 - 2.0) (25) (85.5) (52) (46)
1.09
0 - 0.08 1.02
3.72 2.52 2.17
YU29LK-B1
YU29LK-BR
1-1/4 NPT 1.65 (41.9) 1.10 - 1.61 1.31
40
(28 - 41)
(33.2) (27.6) 70
(0 - 2.0) (26) (94.4) (64) (55)
1.09
0 - 0.08 1.04
3.72 2.52 2.17
YU36NK-B1
YU36NK-BR
1-1/2 NPT 1.92 (48.7) 1.10 - 1.61 1.31
40
(28 - 41)
(33.2) (27.6) 70
(0 - 2.0) (26.5) (94.4) (64) (55)
- 2.07 1.74
1.48
0 - 0.10 1.06
4.58 2.87 2.56
YU50NK-B1
YU50NK-BR
2 NPT
50
2.375 (60.4) 1.42
(36 - 52.6) (44.2) (37.5) 85
(0 - 2.5) (27) (116.3) (73) (65)
1.86
0 - 0.10 1.57
5.02 3.54 3.15
YU52NK-B1
YU52NK-BR
2-1/2 NPT 2.875 (74.1) 1.81 - 2.57 2.21
63
(46 - 65.3) (56.2) (47.3) 120 (0 - 2.5) (40) (127.6) (90) (80)
- 3.07 2.69
2.28
0 - 0.10 1.63
5.37 4.21 3.74
YU30NK-B1
YU30NK-BR
3 NPT
75
3.50 (88.9) 2.24
(57 - 78)
(68.2) (58.0) 150 (0 - 2.5) (41.5) (136.5) (107) (95)
YU20MK-B1

YU20MK-BR

20 - 1

M20 x 1.5

.79 (20)

YU20MM-B1

YU20MM-BR

20 - 2

M20 x 1.5

.79 (20)

YU20ML-B1

YU20ML-BR

20 - 3

M20 x 1.5

.79 (20)

YU25MK-B1

YU25MK-BR

20 - 3

M25 x 1.5

.98 (25)

YU25MM-B1

YU25MM-BR

25

M25 x 1.5

.98 (25)

YU32MK-B1

YU32MK-BR

32

M32 x 1.5

1.26 (32)

YU40MK-B1

YU40MK-BR

40

M40 x 1.5

1.57 (40)

YU50MK-B1

YU50MK-BR

50

M50 x 1.5

1.97 (50)

YU63MK-B1

YU63MK-BR

63

M63 x 1.5

2.48 (63)

YU75MK-B1

YU75MK-BR

75

M75 x 1.5

2.95 (75)

.24 - .47
(6 - 12)
.35 - .63
(9 - 16)
.49 - .81
(12.5 - 20.5)
.49 - .81
(12.5 - 20.5)
.67 - 1.02
(16.9 - 26)
.87 - 1.30
(22 - 33)
1.10 - 1.61
(28 - 41)
1.42 - 2.07
(36 - 52.6)
1.81 - 2.57
(46 - 65.3)
2.24 - 3.07
(57 - 78)

.32
(8.2)
.47
(12)
.55
(14)
.55
(14)
.79
(20)
1.02
(26)
1.31
(33.2)
1.74
(44.2)
2.21
(56.2)
2.69
(68.2)

.31
(7.9)
.35
(8.8)
.45
(11.5)
.45
(11.5)
65
(16.4)
.84
(21.4)
1.09
(27.6)
1.48
(37.5)
1.86
(47.3)
2.28
(58.0)

8
10
15
15
25
45
70
85
120
150

0 - 0.05
(0 - 1.25)
0 - 0.05
(0 - 1.25)
0 - 0.06
(0 - 1.4)
0 - 0.06
(0 - 1.4)
0 - 0.06
(0 - 1.6)
0 - 0.08
(0 - 2.0)
0 - 0.08
(0 - 2.0)
0 - 0.10
(0 - 2.5)
0 - 0.10
(0 - 2.5)
0 - 0.10
(0 - 2.5)

.63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)

2.74
(69.5)
2.93
(74.3)
3.14
(80.5)
3.17
(80.5)
3.58
(91)
3.78
(96)
4.21
(107)
5.18
(131.5)
5.69
(144.5)
6.06
(154)

1.06
(27)
1.14
(29)
1.38
(35)
1.38
(35)
1.65
(42)
2.05
(52)
2.52
(64)
2.87
(73)
3.54
(90)
4.21
(107)

.87
(22)
.94
(24)
1.18
(30)
1.18
(30)
1.42
(36)
1.81
(46)
2.17
(55)
2.56
(65)
3.15
(80)
3.74
(95)

Technical
Information

Ex-e / Ex-d
Accessories

Ex-e Conduit &


Fitting Systems

Ex-e EMI / RFI Nickel


Plated Brass Glands

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Ex-e Multi-Hole &


Romex Glands

EXIOS (UL +Barrier) Cable Glands - NPT / Metric


UL / Ex-d (Flameproof) / Ex-e

EXIOS UL Barrier / Certificates


UL 2225 / UL 514 B / CSA 22.2
UL File: 351373

www.sealconex.com

Class I; Div 1; Groups C, D


Class I; Div 2; Groups C, D

Class II; Div 1; Groups E, F, G


Class II; Div 2; Groups E, F, G

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Class III
Class I; Zone 1; AEx d IIB

L1
.79
(20)
.79
(20)
.79
(20)
1.18
(30)
1.18
(30)
1.18
(30)
1.38
(35)
1.57
(40)
1.77
(45)
.79
(20)
.79
(20)
.79
(20)
.79
(20)
.79
(20)
1.18
(30)
1.18
(30)
1.38
(35)
1.57
(40)
1.77
(45)

Ex-d EXIOS
Cable Glands

UL File: E351373

EXIOS (UL +Barrier) Cable Glands - Introduction


UL / Ex-d (Flameproof) / Ex-e
For Armored Cable with Compound

Ex-d Nickel Plated Brass &


Stainless Steel Glands

These cable glands are designed for use in Hazardous Areas. The compound provides a Barrier seal around each
cable core according to North American specifications.
The UL-Certified version is for use with Marine Shipboard cables in Hazardous Areas. The EXIOS Barrier can also be
used in Zone classified Hazardous Locations.
Certifications / Approvals
Class I; Div 1; Groups C,D
Class I; Div 2; Groups C,D
Class I; Zone 1; AEx d IIB

Class II; Div 1; Groups E, F, G


Class II; Div 2; Groups E, F, G
Class III

Ex-e
Nylon Glands

UL 2225 / UL 514 B / CSA 22.2


UL File: E351373

Ex-e Multi-Hole &


Romex Glands

YU Overlapping Clamping Splines seal


outer jacket of the cable

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Armor accepts thickness from


0 - 0.10 (0 - 2.5 mm)
Maximum clamping range - up to
3.75 (95 mm)
Captive Interlocking Armor Cone:
Safe & Secure Assembly!
Octagon Design keeps torque off
cable and armor!

Ex-e EMI / RFI Nickel


Plated Brass Glands

Temperature:
-13F to 185F (- 25C to 85C)

Ex-e Conduit &


Fitting Systems

UL File: E351373

Ex-e / Ex-d
Accessories

EXIOS Barrier

The EXIOS +Barrier gland combines the outstanding


features of the +Standard EXIOS but with additional Ex-d
(Flameproof) barrier using the compound.

www.sealconex.com

Technical
Information

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Ex-d EXIOS
Cable Glands

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Ex-e
Nylon Glands

I M2 Ex de I Mb IIC Gb / I M2 Ex ta IIIC Da

For Armored Cable with Compound

Raw Brass
Brass, Cable Glands EXIOS +Barrier for Hazardous Duty Locations, Nylon Clamping Insert, Silicone O-Ring & Seals, V2, UL94, IP 68 (5 bar)
Part Numbers
Size
Thread
Dimensions in Inches (mm)
(See Diagram Below)
-76F to 185F
Type
Type
Cable
(- 60C to 85C)
Cable
Range
Dia.
Thread
& Size
Clearance
Range
Inner
Over
Max.
Length
Page 59
Hole
for Thread
Jacket
Cond.
No.
Armor
H
Specs
+.01 (+.25 mm)
A1
A2
A3
Cond. Range
GL
max
D
mm
L1
24
.47
.32
.31
0
0.05
.63
2.52
1.06
.87
.79
YP09NK-BB
20 - 1 3/8 NPT *
.68 (17.2)
8
(6 - 12)
(8.2)
(7.9)
(0 - 1.25)
(16)
(64)
(27)
(22)
(20)
.35 - .63
.47
.35
0 - 0.05
.63
2.68
1.14
.94
.79
YP13NM-BB
1/2 NPT
20 - 2
.83 (21.1)
10
(9 - 16)
(12)
(8.8)
(0 - 1.25)
(16)
(68)
(29)
(24)
(20)
.49 - .81
.55
.45
0 - 0.06
.63
2.87
1.38
1.18
.79
YP13NL-BB
1/2 NPT
20 - 3
.83 (21.1)
15
(12.5 - 20.5)
(14)
(11.5)
(0 - 1.4)
(16)
(73)
(35)
(30)
(20)
.67 - 1.02
.79
.65
0 - 0.06
.63
3.2
1.65
1.42
.79
YP21NK-BB
3/4 NPT
25
1.05 (26.7)
25
(16.9 - 26)
(20)
(16 .4)
(0 - 1.6)
(16)
(81.3)
(42)
(36)
(20)
.87 - 1.30
1.02
.84
0 - 0.08
.63
3.37
2.05
1.81
1.18
YP29NK-BB
1 NPT
32
1.35 (34.3)
45
(22 - 33)
(26)
(21.4)
(0 - 2.0)
(16)
(85.5)
(52)
(46)
(30)
1.10
1.61
1.31
1.09
0
0.08
.63
3.72
2.52
2.17
1.18
YP29LK-BB
1-1/4 NPT 1.65 (41.9)
40
70
(28 - 41)
(33.2)
(27.6)
(0 - 2.0)
(16)
(94.4)
(64)
(55)
(30)
1.10
1.61
1.31
1.09
0
0.08
.63
3.72
2.52
2.17
1.18
YP36NK-BB
1-1/2
NPT
40
1.92 (48.7)
70
(28 - 41)
(33.2)
(27.6)
(0 - 2.0)
(16)
(94.4)
(64)
(55)
(30)
1.42
2.07
1.74
1.48
0 - 0.10
.63
4.58
2.87
2.56
1.38
YP50NK-BB
2 NPT
50
2.375 (60.4) (36 - 52.6)
85
(44.2)
(37.5)
(0 - 2.5)
(16)
(116.3) (73)
(65)
(35)
2.21
1.86
0 - 0.10
.63
5.02
3.54
3.15
1.57
YP52NK-BB
2-1/2 NPT 2.875 (74.1) 1.81 - 2.57
63
120
(46 - 65.3)
(56.2)
(47.3)
(0 - 2.5)
(16)
(127.6) (90)
(80)
(40)
2.24 - 3.07
2.69
2.28
0 - 0.10
.63
5.37
4.21
3.74
1.77
YP30NK-BB
3 NPT
75
3.50 (88.9)
150
(57 - 78)
(68.2)
(58.0)
(0 - 2.5)
(16)
(136.5) (107)
(95)
(45)

Ex-e EMI / RFI Nickel


Plated Brass Glands

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Ex-e Multi-Hole &


Romex Glands

US

YP16MK-BB

20 - 1

M16 x 1.5 *

.63 (16)

YP20MK-BB

20 - 1

M20 x 1.5

.79 (20)

YP20MM-BB

20 - 2

M20 x 1.5

.79 (20)

YP20ML-BB

20 - 3

M20 x 1.5

.79 (20)

YP25MK-BB

20 - 3

M25 x 1.5

.98 (25)

YP25MM-BB

25

M25 x 1.5

.98 (25)

YP32MK-BB

32

M32 x 1.5

1.26 (32)

YP40MK-BB

40

M40 x 1.5

1.57 (40)

YP50MK-BB

50

M50 x 1.5

1.97 (50)

YP63MK-BB

63

M63 x 1.5

2.48 (63)

YP75MK-BB

75

M75 x 1.5

2.95 (75)

.24 - .47
(6 - 12)
.24 - .47
(6 - 12)
.35 - .63
(9 - 16)
.49 - .81
(12.5 - 20.5)
.49 - .81
(12.5 - 20.5)
.67 - 1.02
(16.9 - 26)
.87 - 1.30
(22 - 33)
1.10 - 1.61
(28 - 41)
1.42 - 2.07
(36 - 52.6)
1.81 - 2.57
(46 - 65.3)
2.24 - 3.07
(57 - 78)

.32
(8.1)
.32
(8.2)
.47
(12)
.55
(14)
.55
(14)
.79
(20)
1.02
(26)
1.31
(33.2)
1.74
(44.2)
2.21
(56.2)
2.69
(68.2)

.31
(7.9)
.31
(7.9)
.35
(8.8)
.45
(11.5)
.45
(11.5)
65
(16.4)
.84
(21.4)
1.09
(27.6)
1.48
(37.5)
1.86
(47.3)
2.28
(58.0)

8
8
10
15
15
25
45
70
85
120
150

0 - 0.05
(0 - 1.25)
0 - 0.05
(0 - 1.25)
0 - 0.05
(0 - 1.25)
0 - 0.06
(0 - 1.4)
0 - 0.06
(0 - 1.4)
0 - 0.06
(0 - 1.6)
0 - 0.08
(0 - 2.0)
0 - 0.08
(0 - 2.0)
0 - 0.10
(0 - 2.5)
0 - 0.10
(0 - 2.5)
0 - 0.10
(0 - 2.5)

.63
(16)
63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)

2.52
(64.0)
2.52
(64.0)
2.68
(68)
2.87
(73)
2.87
(73)
3.2
(81.3)
3.37
(85.5)
3.72
(94.4)
4.58
(116.3)
5.02
(127.6)
5.37
(136.5)

1.06
(27)
1.06
(27)
1.14
(29)
1.38
(35)
1.38
(35)
1.65
(42)
2.05
(52)
2.52
(64)
2.87
(73)
3.54
(90)
4.21
(107)

.87
(22)
.87
(22)
.94
(24)
1.18
(30)
1.18
(30)
1.42
(36)
1.81
(46)
2.17
(55)
2.56
(65)
3.15
(80)
3.74
(95)

.79
(20)
.79
(20)
.79
(20)
.79
(20)
.79
(20)
.79
(20)
1.18
(30)
1.18
(30)
1.38
(35)
1.57
(40)
1.77
(45)

Materials Alternative Part Number Key (Last 2 letters)


Parts listed above are Raw Brass, as indicated by the part number ending BB. For Nickel Plated Brass, order part number ending BR. For (316L) Stainless Steel, order part number
ending SS. For Nickel Plated Brass Threads with Brass Body, order part number ending B1. Accessories Available.

* Group II Certified only through IECEx

Compound is included with every gland!

Class I, Zone 1 Approved!

Technical
Information

Ex-e / Ex-d
Accessories

Ex-e Conduit &


Fitting Systems

EXIOS (+Barrier) Cable Glands - NPT / Metric


cUS / ATEX / IECEx / Ex-d (Flameproof) / Ex-e

ATEX

EXIOS Barrier / Certificates


IEC 60079-0:2007-10
EN 60079-7:2007

IEC 60079-1:2007-4
EN 60079-31:2009

www.sealconex.com

IEC 60079-7:2006-7
EN 60529

IEC 60079-31:2008
IECEx Sir 11.0044X

EN 60079-0:2009
Sira-11 ATEX 1110-X

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

EN 60079-1:2007

min. L2

L1

Step 1

A1

A3

Ex-d EXIOS
Cable Glands

EXIOS (+Barrier / UL +Barrier) Cable Glands


Assembly Instructions

Ex-d Nickel Plated Brass &


Stainless Steel Glands

The cable is to be prepared as shown in Fig. 1. Measurements L1 should be followed. Measurement


L1 can be found in Table 1 (Page 11). Choose measurement L2 depending on the installation.
Fig. 3

Important

The Exios Barrier Cable Gland is typically designed for use with armored cables.
However, it is also possible to use with NON-ARMORED cables. In this case it is
important to use one clamping ring as a spacer for the installation!

Fig. 1

A2
Step 2

The cable gland is delivered with 2 armor clamping rings. Choose the appropriate clamping ring the other
one must not be used. Remove the brass compound tube. After that, prepare the installation as in Fig. 2.
Care should be taken with the correct installation of the armor clamping ring, Fig. 3.

Step 3

Ex-e
Nylon Glands

Install the entry component on the device or housing 11.06 Lb-Ft (15 Nm). The end-user is responsible for ensuring
that, at the point of installation, the adapter for the entry component has been made ready in accordance with
Regulations. The entry component can be provided with a locknut to keep it from working loose.

Fig. 2
Fig. 5

Step 4
Fig. 4

Ex-e Multi-Hole &


Romex Glands

Position the armor of the cable so that all parts of the armor
are in contact with the armor cone (Fig. 4) and the ends of
the armor touches the edge of the armor cone.
Now screw the gland body hand-tight onto the entry component. It helps if, while doing so, the cable is pushed slightly in
towards the device or housing. Finally, with the appropriate
open-ended spanner, tighten fast in order to securely clamp
the armor.

Step 5

Loosen the gland body and check for correct seating of the armor (Fig. 5). The armor must be firmly clamped. If needed, repeat Step 4.

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Preparing the Compound:

Please check the compounds expiration date and take note of the contents of the attached Safety Data sheet. Use the protective gloves included, as well as
suitable eye protection. The compound can be applied at tempertures between +10C and +40C . Application is ideally carried out at room temperature (+20C).
Processing time is approx. 15 min.

Step 6

Fig. 7
LC

Ex-e EMI / RFI Nickel


Plated Brass Glands

Mix and knead the appropriate quantity of compound for the job until a completely uniform color is
achieved. As in Fig. 6, apply the compound between and around the individual conductors.
Filling the sleeve completely is easy if
Clean sleeve
the compound has first been given a
outer shell
conical shape as shown in Fig. 7. The
conductors can be fixed with tape to
prevent them from moving out of place.
Fig. 8.

Fig. 6
Fig. 8
Push the sleeve and the armor cone together. This causes the compound to be compressed. Remove the excess compound. Care should be taken that sleeve has
been filled to the end. If neccessary, wipe the outside of the sleeve to keep the surface clean.

Step 7

Step 8

Carefully insert the sleeve into the entry component.

Ex-e Conduit &


Fitting Systems

Step 9

After the entry component and gland body have been threaded together,
the dome nut can now be tightened. Start tightening by hand to speed up
assembly time. Tighten using an open-ended spanner (4 Nm). Fig 9 & 10

Fig. 9

Fig. 10

1. Entry Components
2. Compound Sleeve

3. Compound
4. Interlocking Armor Cone

5. Armor Clamping Ring


6. Gland Body

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

7. Outer Jacket Sealing


8. Dome Nut Top

www.sealconex.com

Technical
Information

Components

Ex-e / Ex-d
Accessories

Ex-d EXIOS
Cable Glands

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Ex-e
Nylon Glands

For Armored Cable

Raw Brass
Brass, Cable Gland EXIOS +Standard for Hazardous Duty Locations, Nylon 6 Clamping Insert, Silicone O-Ring/Seals, V2, UL94, IP 68, 5 bar
Part Numbers
Size
Thread
Dimensions in Inches (mm)
(See Diagram Below)
-76F to 221F
Type
Type
(- 60C to 105C)
Cable
Cable
Thread
& Size
Clearance
Page 59
Range
Range
Length
Hole
for Thread
Armor
H
Specs
+.01 (+.25 mm)
A1
A2
Range
GL
(+Standard)
D
mm
.24
.47
.12
.32
.63
2.74
1.06
.87
0
0.05
YE09NK-BB
3/8 NPT
20 - 1
.68 (17.2)
(0 - 1.25)
(6 - 12)
(3 - 8.1)
(16)
(69.5)
(27)
(22)
.35 - .63
.24 - .47
.79
2.93
1.14
.94
0 - 0.05
YE13NM-BB
1/2 NPT
20 - 2
.83 (21.1)
(0 - 1.25)
(9 - 16)
(6 - 12)
(20)
(74.3)
(29)
(24)
.49 - .81
.35 - .55
.79
3.17
1.38
1.18
0 - 0.06
YE13NL-BB
1/2 NPT
20 - 3
.83 (21.1)
(0 - 1.4)
(12.5 - 20.5)
(9 - 14)
(20)
(80.5)
(35)
(30)
.67
1.02
.49
.81
.81
3.58
1.65
1.42
0
0.06
YE21NK-BB
3/4 NPT
25
1.05 (26.7)
(0 - 1.6)
(16.9 - 26) (12.5 - 20.5)
(20.5)
(91)
(42)
(36)
.87
1.30
.67
1.02
.98
3.78
2.05
1.81
0
0.08
YE29NK-BB
1 NPT
32
1.35 (34.3)
(0 - 2.0)
(22 - 33)
(16.9 - 26)
(25)
(96)
(52)
(46)
1.10
1.61
.87
1.30
1.02
4.21
2.52
2.17
0
0.08
YE29LK-BB
1-1/4 NPT 1.65 (41.9)
40
(0 - 2.0)
(28 - 41)
(22 - 33)
(26)
(107)
(64)
(55)
1.10
1.61
.87
1.30
1.04
4.21
2.52
2.17
0
0.08
YE36NK-BB
1-1/2 NPT 1.92 (48.7)
40
(0 - 2.0)
(28 - 41)
(22 - 33)
(26.5)
(107)
(64)
(55)
1.42
2.07
1.14
1.75
1.06
5.18
2.87
2.56
0
0.10
YE50NK-BB
2 NPT
50
2.375 (60.4)
(0 - 2.5)
(36 - 52.6) (28.9 - 44.4)
(27)
(131.5)
(73)
(65)
1.81
2.57
1.57
2.22
1.57
5.69
3.54
3.15
0
0.10
YE52NK-BB
2-1/2 NPT 2.875 (74.1)
63
(0 - 2.5)
(46 - 65.3) (39.9 - 56.3)
(40)
(144.5)
(90)
(80)
2.24
3.07
1.99
2.69
1.63
6.06
4.21
3.74
0
0.10
YE30NK-BB
3 NPT
75
3.50 (88.9)
(0 - 2.5)
(57 - 78)
(50.5 - 68.2)
(41.5)
(154)
(107)
(95)

Ex-e EMI / RFI Nickel


Plated Brass Glands

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Ex-e Multi-Hole &


Romex Glands

US

II 2G Ex de IIC Gb / II 1D Ex ta IIIC Da

YE16MK-BB

20 - 1

M16 x 1.5

.63 (16)

YE20MK-BB

20 - 1

M20 x 1.5

.79 (20)

YE20MM-BB

20 - 2

M20 x 1.5

.79 (20)

YE20ML-BB

20 - 3

M20 x 1.5

.79 (20)

YE25MK-BB

20 - 3

M25 x 1.5

.98 (25)

YE25MM-BB

25

M25 x 1.5

.98 (25)

YE32MK-BB

32

M32 x 1.5

1.26 (32)

YE40MK-BB

40

M40 x 1.5

1.57 (40)

YE50MK-BB

50

M50 x 1.5

1.97 (50)

YE63MK-BB

63

M63 x 1.5

2.48 (63)

YE75MK-BB

75

M75 x 1.5

2.95 (75)

24 - .47
(6 - 12)
24 - .47
(6 - 12)
.35 - .63
(9 - 16)
.49 - .81
(12.5 - 20.5)
.49 - .81
(12.5 - 20.5)
.67 - 1.20
(16.9 - 26)
.87 - 1.30
(22 - 33)
1.10 - 1.61
(28 - 41)
1.42 - 2.07
(36 - 52.6)
1.81 - 2.57
(46 - 65.3)
2.24 - 3.07
(57 - 78)

.12 - .32
(3 - 8.1)
.12 - .32
(3 - 8.1)
.24 - .47
(6 - 12)
.35 - .55
(9 - 14)
.35 - .55
(9 - 14)
.49 - .81
(12.5 - 20.5)
.67 - 1.02
(16.9 - 26)
.87 - 1.30
(22 - 33)
1.14 - 1.75
(28.9 - 44.4)
1.57 - 2.22
(39.9 - 56.3)
1.99 - 2.69
(50.5 - 68.2)

0 - 0.05
(0 - 1.25)
0 - 0.05
(0 - 1.25)
0 - 0.05
(0 - 1.25)
0 - 0.06
(0 - 1.4)
0 - 0.06
(0 - 1.4)
0 - 0.06
(0 - 1.6)
0 - 0.08
(0 - 2.0)
0 - 0.08
(0 - 2.0)
0 - 0.10
(0 - 2.5)
0 - 0.10
(0 - 2.5)
0 - 0.10
(0 - 2.5)

63
(16)
63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)

2.74
(69.5)
2.74
(69.5)
2.93
(74.3)
3.17
(80.5)
3.17
(80.5)
3.58
(91)
3.78
(96)
4.21
(107)
5.18
(131.5)
5.69
(144.5)
6.06
(154)

1.06
(27)
1.06
(27)
1.14
(29)
1.38
(35)
1.38
(35)
1.65
(42)
2.05
(52)
2.52
(64)
2.87
(73)
3.54
(90)
4.21
(107)

Technical
Information

.87
(22)
.87
(22)
.94
(24)
1.18
(30)
1.18
(30)
1.42
(36)
1.81
(46)
2.17
(55)
2.56
(65)
3.15
(80)
3.74
(95)

Materials Alternative Part Number Key (Last 2 letters)


Parts listed above are Raw Brass, as indicated by the part number ending BB. For Nickel Plated Brass, order part number ending BR. For (316L) Stainless Steel, order part number
ending SS. For Nickel Plated Brass Threads with Brass Body, order part number ending B1. Accessories Available.

Ex-e / Ex-d
Accessories

Ex-e Conduit &


Fitting Systems

EXIOS (+Standard) Cable Glands - NPT / Metric


cUS / ATEX / IECEx / Ex-d (Flameproof) / Ex-e

ATEX

EXIOS Standards / Certificates


IEC 60079-0:2007-10
EN 60079-1:2007
BVS-10-ATEX-E-062-X

www.sealconex.com

IEC 60079-1:2007-4
EN 60079-7:2007
AEX-13499-X

IEC 60079-7:2006-7
EN 60079-31:2009
CSA:12.2557737X

IEC 60079-31:2008
EN 60529

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

EN 60079-0:2009
IECEx BVS 10.0078X

US

Ex-d EXIOS
Cable Glands

EXIOS (+MZ) Cable Glands - NPT / Metric


cUS / ATEX / IECEx / Ex-d (Flameproof) / Ex-e

ATEX

For Armored Cable

II 2G Ex de IIC Gb / II 1D Ex ta IIIC Da

YZ20MK-BB

20 - 1

M20 x 1.5

.79 (20)

YZ20MM-BB

20 - 2

M20 x 1.5

.79 (20)

YZ20ML-BB

20 - 3

M20 x 1.5

.79 (20)

YZ25MK-BB

20 - 3

M25 x 1.5

.98 (25)

YZ25MM-BB

25

M25 x 1.5

.98 (25)

YZ32MK-BB

32

M32 x 1.5

1.26 (32)

YZ40MK-BB

40

M40 x 1.5

1.57 (40)

YZ50MK-BB

50

M50 x 1.5

1.97 (50)

YZ63MK-BB

63

M63 x 1.5

2.48 (63)

YZ75MK-BB

75

M75 x 1.5

2.95 (75)

.12 - .32
(3 - 8.1)
.12 - .32
(3 - 8.1)
.24 - .47
(6 - 12)
.35 - .55
(9 - 14)
.35 - .55
(9 - 14)
.49 - .81
(12.5 - 20.5)
.67 - 1.02
(16.9 - 26)
.87 - 1.30
(22 - 33)
1.14 - 1.75
(28.9 - 44.4)
1.57 - 2.22
(39.9 - 56.3)
1.99 - 2.69
(50.5 - 68.2)

0 - 0.05
(0 - 1.25)
0 - 0.05
(0 - 1.25)
0 - 0.05
(0 - 1.25)
0 - 0.06
(0 - 1.4)
0 - 0.06
(0 - 1.4)
0 - 0.06
(0 - 1.6)
0 - 0.08
(0 - 2.0)
0 - 0.08
(0 - 2.0)
0 - 0.10
(0 - 2.5)
0 - 0.10
(0 - 2.5)
0 - 0.10
(0 - 2.5)

63
(16)
63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)
.63
(16)

3.11
(79)
3.11
(79)
3.30
(83.8)
3.60
(91.5)
3.60
(91.5)
4.16
(105.7)
4.21
(107)
4.72
(120)
5.69
(144.5)
6.20
(157.5)
6.57
(167)

1.06
(27)
1.06
(27)
1.14
(29)
1.38
(35)
1.38
(35)
1.65
(42)
2.05
(52)
2.52
(64)
2.87
(73)
3.54
(90)
4.21
(107)

.87
(22)
.87
(22)
.94
(24)
1.18
(30)
1.18
(30)
1.42
(36)
1.81
(46)
2.17
(55)
2.56
(65)
3.15
(80)
3.74
(95)

Ex-e Conduit &


Fitting Systems

24 - .47
(6 - 12)
24 - .47
(6 - 12)
.35 - .63
(9 - 16)
.49 - .81
(12.5 - 20.5)
.49 - .81
(12.5 - 20.5)
.67 - 1.20
(16.9 - 26)
.87 - 1.30
(22 - 33)
1.10 - 1.61
(28 - 41)
1.42 - 2.07
(36 - 52.6)
1.81 - 2.57
(46 - 65.3)
2.24 - 3.07
(57 - 78)

Ex-e EMI / RFI Nickel


Plated Brass Glands

.63 (16)

Ex-e Nickel Plated Brass &


Stainless Steel Glands

M16 x 1.5

Ex-e Multi-Hole &


Romex Glands

20 - 1

mm
.87
(22)
.94
(24)
1.18
(30)
1.42
(36)
1.81
(46)
2.17
(55)
2.17
(55)
2.56
(65)
3.15
(80)
3.74
(95)

Ex-e
Nylon Glands

YZ16MK-BB

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Raw Brass
Brass, Cable Gland EXIOS +MZ for Hazardous Duty Locations, Nylon 6 Clamping Insert, Silicone O-Ring/Seals, V2, UL94, IP 68, 5 bar
Part Numbers
Size Type Thread Type
Dimensions in Inches (mm)
(See Diagram Below)
-76F to 221F
& Size
(- 60C to 105C)
Cable
Cable
Thread
Clearance
Page 59
Range
Range
Length
Hole
for Thread
Armor
H
Specs
+.01 (+.25 mm)
A1
A2
Range
GL
(+MZ)
D
.24
.43
.12
.32
.63
3.11
1.06
0
0.05
YZ09NK-BB
3/8 NPT
20 - 1
.68 (17.2)
(0 - 1.25)
(6 - 11)
(3 - 8.1)
(16)
(79)
(27)
.35
.51
.24
.47
.79
3.30
1.14
0
0.05
YZ13NM-BB
1/2 NPT
20 - 2
.83 (21.1)
(0 - 1.25)
(9 - 13)
(6 - 12)
(20)
(83.8)
(29)
.49
.69
.35
.55
.79
3.60
1.38
0
0.06
YZ13NL-BB
1/2 NPT
20 - 3
.83 (21.1)
(0 - 1.4)
(12.5 - 17.5)
(9 - 14)
(20)
(91.5)
(35)
.67
.94
.49
.81
.81
4.16
1.65
0
0.06
YZ21NK-BB
3/4 NPT
25
1.05 (26.7)
(0 - 1.6)
(16.9 - 24) (12.5 - 20.5)
(20.5)
(105.7)
(42)
.87
1.28
.67
1.02
.98
4.21
2.05
0
0.08
YZ29NK-BB
1 NPT
32
1.35 (34.3)
(0 - 2.0)
(22 - 32.5)
(16.9 - 26)
(25)
(107)
(52)
1.10
1.56
.87
1.30
1.02
4.21
2.52
0
0.08
YZ29LK-BB
1-1/4 NPT
40
1.65 (41.9)
(0 - 2.0)
(28 - 39.5)
(22 - 33)
(26)
(107)
(64)
1.10
1.56
.87
1.30
1.04
4.72
2.52
0
0.08
YZ36NK-BB
1-1/2 NPT
40
1.92 (48.7)
(0 - 2.0)
(28 - 39.5)
(22 - 33)
(26.5)
(120)
(64)
1.42
1.93
1.14
1.75
1.06
5.69
2.87
0
0.10
YZ50NK-BB
2 NPT
50
2.375 (60.4)
(0 - 2.5)
(36 - 49)
(28.9 - 44.4)
(27)
(144.5)
(73)
1.81
2.52
1.57
2.22
1.57
6.20
3.54
0
0.10
YZ52NK-BB
2-1/2 NPT 2.875 (74.1)
63
(0 - 2.5)
(46 - 64)
(39.9 - 56.3)
(40)
(157.5)
(90)
2.24
3.07
1.99
2.69
1.63
6.57
4.21
0
0.10
YZ30NK-BB
3 NPT
75
3.50 (88.9)
(0 - 2.5)
(57 - 78)
(50.5 - 68.2)
(41.5)
(167)
(107)

Materials Alternative Part Number Key (Last 2 letters)


Parts listed above are Raw Brass, as indicated by the part number ending BB. For Nickel Plated Brass, order part number ending BR. For (316L) Stainless Steel, order part number
ending SS. For Nickel Plated Brass Threads with Brass Body, order part number ending B1. Accessories Available.

Ex-e / Ex-d
Accessories

*A1 Cable Range for MZ style EXIOS is slightly smaller

EXIOS Standards / Certificates



IEC 60079-1:2007-4
EN 60079-7:2007
AEX-13499-X

IEC 60079-7:2006-7
EN 60079-31:2009
CSA:12.2557737X

IEC 60079-31:2008
EN 60529

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

EN 60079-0:2009
IECEx BVS 10.0078X

www.sealconex.com

Technical
Information

IEC 60079-0:2007-10
EN 60079-1:2007
BVS-10-ATEX-E-062-X

Ex-d EXIOS
Cable Glands

EXIOS (+Standard / +MZ) Cable Glands - Overview


cUS / ATEX / IECEx / Ex-d (Flameproof) / Ex-e

Ex-d Nickel Plated Brass &


Stainless Steel Glands

(YE-) Double Compression Gland

Ex-e
Nylon Glands

Armor Options: Braid, Single Wire and Tape Armor

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Ex-e Multi-Hole &


Romex Glands

Time-proven Hummel clamping system. Innovative Interlocking Armor Cone for zero torsion on
cable cores and armor. Armor acceptance from 0 - 2.5 mm (0.1). Fast and easy assembly by
hand, by use of profile material with maximum grip.

(YZ-) Double Compression Gland with Additional Torque Prevention Clamp

Ex-e EMI / RFI Nickel


Plated Brass Glands

Armor Options: Braid, Single Wire and Tape Armor

Technical
Information

Ex-e / Ex-d
Accessories

Ex-e Conduit &


Fitting Systems

The MZ Clamp helps prevent shield or wire armor from shearing off under excessive cable torque.

Improved Pull-Out
Resistance &
Stronger Grip
on Jacket
10

www.sealconex.com

Nickel Plated
Brass Option
Silicone O-Rings

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Step 1

L1

min. L2

A1

A2

Ex-d Nickel Plated Brass &


Stainless Steel Glands

The cable is to be prepared as shown in Fig. 1. Measurement L1 should be


followed as shown in Table 1. Choose measurement L2 depending on the
application. The inner cable jacket must be free of damage and should extend
beyond the cable gland.
Fig. 3

Ex-d EXIOS
Cable Glands

EXIOS (+Standard / +MZ) Cable Glands


Assembly Instructions

( For Standard EXIOS only! )

Fig. 1

Step 2

The cable gland is delivered with 2 armor clamping rings. Choose the appropriate
clamping ring as per Table 1; the other ring will not be used. Prepare the installation
as shown in Fig. 2. Care should be taken with the correct installation of the clamping
ring, Fig. 3.

Size
Type
Fig. 2
Install the entry component on the device or housing in question 11.06 Lb-Ft
(15 Nm). The end-user is responsible for ensuring that, at the point of installation,
the adapter for the entry component has been made ready in accordance with
Regulations. The entry component can be provided with a locknut to keep it from
working loose.

Step 4

Screw the gland body hand-tight onto the entry component. It helps if, while doing so, the cable is pushed slightly in towards the device or housing. Finally, with
the appropriate open-ended spanner, tighten roughly 1/2 a turn more to securely
clamp the armour.

20 - 1

3/8 NPT

20 - 2

1/2 NPT

20 - 3

1/2 NPT

25

3/4 NPT

32

1 NPT

40

Dimensions in Inches (mm)

Metric

L1

M16 x 1.5

* L2

.79 (20)

.98 (25)

.79 (20)

1.38 (35)

.79 (20)

1.38 (35)

M25 x 1.5

.79 (20)

1.38 (35)

M32 x 1.5

1.18 (30)

1.38 (35)

1-1/4 NPT

M40 x 1.5

1.18 (30)

1.38 (35)

40

1-1/2 NPT

M40 x 1.5

1.18 (30)

1.38 (35)

50

2 NPT

M50 x 1.5

1.38 (35)

1.77 (45)

63

2-1/2 NPT

M63 x 1.5

1.57 (40)

1.77 (45)

75

3 NPT

M75 x 1.5

1.77 (45)

1.77 (45)

M20 x 1.5
M20 x 1.5
M20 x 1.5
M25 x 1.5

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Position the armour of the cable so that all parts of the armor are in contact with
the armor cone (Fig. 4) and the ends of the armour touches the edge of the
armor cone.

NPT

Ex-e Multi-Hole &


Romex Glands

Step 3

Thread Type & Size

Ex-e
Nylon Glands

Table 1

* Length depends on installation or customer preference

Fig. 4

Fig. 5

Step 6

After the entry component and gland body have been threaded together as per Step
4 Lb-Ft (Nm), the dome nut can now be tightened. Start tightening by hand to speed
up assembly. Tighten using an open-ended spanner (Nm).

Step 7

Tighten 2 screws on MZ Clamp (YZ Only)

YE-

1. Entry Components
2. Inter Jacket Sealing

7
5. Gland Body
6. Outer Jacket Sealing

3. Interlocking Armor Cone


4. Armor Clamping Ring

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

7. Dome Nut Top


8. MZ Clamp

www.sealconex.com

11

Technical
Information

Components

Ex-e / Ex-d
Accessories

YZ-

Ex-e Conduit &


Fitting Systems

Loosen the gland body and check for correct seating of the armor
(Fig. 5). The armor must be firmly clamped. If needed, repeat step 4.
The o-ring on the armor cone is only for ease of installation. Damage
or removal does not affect the function of the gland.

Ex-e EMI / RFI Nickel


Plated Brass Glands

Step 5

Ex-d EXIOS
Cable Glands

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Ex-e
Nylon Glands

Ex-e Multi-Hole &


Romex Glands

US

For Non-Armored Cable

AEx de IIC Gb / AEx ta IIIC

Raw Brass
Brass, Cable Glands EXIOS +A2F for Non-Armored Hazardous Duty Locations, Nylon 6 Clamping Insert, Silicone O-Ring & Seals,
Protection Class V2, UL94, IP 66/67/68, 5 bar
Part Numbers
Gland
Thread
Dimensions in Inches (mm)
-76F to 221F
Size
Type
(- 60C to 105C)
Cable
Thread
Clearance
Range
Length
Page 59
Hole
H
for Thread
Specs
A1
GL
max
D
mm
+.01 (+.25 mm)
YA09NK-BB
20 - 1
3/8 NPT
.68 (17.2)
24 - .47 (6 - 12)
.63 (16)
1.40 (35.6)
1.06 (27)
.87 (22)
YA13NK-BB
20 - 1
1/2 NPT
.83 (21.1)
24 - .47 (6 - 12)
.79 (20)
1.40 (35.6)
1.14 (29)
.87 (24)
YA13NM-BB
20 - 2
1/2 NPT
.83 (21.1)
.35 - .63 (9 - 16)
.79 (20)
1.44 (36.5)
1.06 (27)
.94 (24)
YA21NK-BB
20 - 3
3/4 NPT
1.05 (26.7)
.49 - .81 (12.5 - 20.5)
.81 (20.5)
1.87 (47.5)
1.38 (35)
1.18 (30)
YA29NK-BB
25
1 NPT
1.35 (34.3)
.67 - 1.02 (16.9 - 26)
.98 (25)
1.88 (47.8)
1.65 (42)
1.42 (36)
YA29LK-BB
32
1 1/4 NPT
1.65 (41.9)
.87 - 1.30 (22 - 33)
1.02 (26)
2.01 (51.1)
2.05 (52)
1.81 (46)
YA36NK-BB
40
1 1/2 NPT
1.92 (48.7)
1.10 - 1.61 (28 - 41)
1.04 (26.5)
2.24 (56.8)
2.52 (64)
2.17 (55)
YA50NK-BB
50
2 NPT
2.375 (60.4) 1.57 - 2.07 (40 - 52.6)
1.06 (27)
2.57 (65.4)
2.87 (73)
2.56 (65)
YA52NK-BB
63
2 1/2 NPT
2.875 (74.1)
2.01 - 2.40 (51 - 61)
1.57 (40)
2.77 (70.3)
3.54 (90)
3.15 (80)
YA30NK-BB
75
3 NPT
3.50 (88.9)
2.44 - 3.07 (62 - 78)
1.63 (41.5)
3.00 (76.2) 4.21 (107)
3.74 (95)
YA16MK-BB
YA20MK-BB
YA20MM-BB
YA25MK-BB
YA32MK-BB
YA40MK-BB
YA50MK-BB
YA63MK-BB
YA75MK-BB
YA90MK-BB

20 - 1
20 - 1
20 - 2
20 - 3
25
32
40
50
63
75

M16 x 1.5
M20 x 1.5
M20 x 1.5
M25 x 1.5
M32 x 1.5
M40 x 1.5
M50 x 1.5
M63 x 1.5
M75 x 1.5
M90 x 2.0

.63 (16)
.79 (20)
.79 (20)
.98 (25)
.98 (25)
1.57 (40)
1.97 (50)
2.48 (63)
2.95 (75)
3.74 (90)

24 - .47 (6 - 12)
24 - .47 (6 - 12)
.35 - .63 (9 - 16)
.49 - .81 (12.5 - 20.5)
.67 - 1.02 (16.9 - 26)
.87 - 1.30 (22 - 33)
1.10 - 1.61 (28 - 41)
1.57 - 2.07 (40 - 52.6)
2.01 - 2.57 (51 - 65.3)
2.44 - 3.07 (62 - 78)

.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)
.79 (20)

1.40 (35.6)
1.40 (35.6)
1.56 (39.7)
1.87 (47.5)
1.88 (47.8)
2.01 (51.1)
2.24 (56.8)
2.57 (65.4)
2.77 (70.3)
3.00 (76.2)

1.06 (27)
1.06 (27)
1.14 (29)
1.38 (35)
1.65 (42)
2.05 (52)
2.52 (64)
2.87 (73)
3.54 (90)
4.21 (107)

.87 (22)
.87 (22)
.94 (24)
1.18 (30)
1.42 (36)
1.81 (46)
2.17 (55)
2.56 (65)
3.15 (80)
3.74 (95)

Materials Alternative Part Number Key (Last 2 letters)


Parts listed above are Raw Brass, as indicated by the part number ending BB. For Nickel Plated Brass, order part number ending BR. For (316L) Stainless Steel, order part number
ending SS. For Nickel Plated Brass Threads with Brass Body, order part number ending B1. Accessories Available.

With the EXIOS A2F, HUMMEL continues to follow the successful design of the EXIOS range of cable
glands. This model is especially designed for unarmored and braided cables for the use in hazardous areas
(cUS), Class 1, Zone 1, Zone 2, Zone 20, Zone 21 and Zone 22, where durability and quality is a must.
US
C
Braid and cable jacket are fed into the Enclosure where the braid must be terminated inside.

Ex-e EMI / RFI Nickel


Plated Brass Glands

Ex-e Nickel Plated Brass &


Stainless Steel Glands

EXIOS (+A2F) Cable Glands - NPT / Metric


cUS / ATEX / IECEx / Ex-d (Flameproof) / Ex-e

ATEX

The EXIOS A2F incorporates the time-proven Hummel clamping system, which offers a large clamping range
in a small gland size. A smaller gland size can often be more cost effective.

Ex-e Conduit &


Fitting Systems

Halogen-free and Phosphorous-free


Silicone Seal and O-Ring are standard

YA-

Technical
Information

Ex-e / Ex-d
Accessories

This Gland can also be used in Non-Hazardous applications!

EXIOS A2F / Certificates


IEC 60079-0 / 2007
EN 60079-7 / 2007

12

IEC 60079-1 / 2007


EN 60079-31 / 2009

www.sealconex.com

IEC 60079-7 / 2006


EN 60529

IEC 60079-31 / 2008


IECEx Nr. DEK 12.0039X

EN 60079-0 / 2009

ATEX Nr. DEKRA 12ATEX0139 X

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

EN 60079-1 / 2007
CSA: 12.2557737X

For Non-Armored Cable







0 UE11

Ref. Standards
EN 60079-0
EN 60079-1
EN 60079-7
EN 60079-31

Ex-e
Nylon Glands

Ex-d Cable Glands for non-armored cable - Cost Saving Option!


Large Cable Range: 0.08 - 1.26 (2 - 32 mm)
NEMA 4x & 6 (IP 67 & 68) - Liquid Tight - Submersible to 300 ft!
Form Seal allows 150 PSIG (10 BAR) rating - Highest in Industry!
IP 69K rated - Ideal in splash or hose down applications!
Non-Corrosive: Resistant to salt water, weak acids, weak alkalis, alcohol, esters,
ketones, ether, gasoline, mineral, animal & vegetable oil
Approvals & Certifications - ATEX/IECEx, CE, Gost and German Lloyd!
RoHS & Deca BDE - Environmentally Compliant to the newest standards!

CAGE

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Technical Description

Ex-d EXIOS
Cable Glands

Nickel Plated Brass & Stainless Steel Cable Glands


Introduction - Ex-d (Flameproof)

Your One Stop Solution For All Cable & Wire Accessories!

Ex-e Multi-Hole &


Romex Glands

Cable Protection
Overlapping clamping splines apply a concentric force to
the cable.

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Unique Product
The high performance elongated green FPM seal
guarantees NEMA 4x & 6 (IP 68 / IP 69K) at 150
PSIG (10 BAR).

Ex-e EMI / RFI Nickel


Plated Brass Glands

Liquid Tight

Machined O-Ring Groove: All of our Metal Cable Glands


come with an O-Ring, resulting in a liquid tight seal between
fitting and installation.

Simply push the cable through Cable Gland


Tighten Dome Nut...Done!
No disassembly of the Cable Glands required!

II 2G 1D Ex d IIC

Ex-e Conduit &


Fitting Systems

ATEX

Time Saving Installation

Ex-e / Ex-d
Accessories

FPM Form Seal


Inserts

Nylon or PVDF
Spline

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Ex-d Hex Plugs


Available in PG and
Metric sizes.

www.sealconex.com

13

Technical
Information

FPM
O-Rings

For Non-Armored Cable


Ex-d/Ex-e Nickel Plated Brass
Brass, Cable Glands for Hazardous Duty Locations, Nylon / PVDF Spline with FPM Insert
Insert, NEMA 6, 150 PSIG, IP 68/69K, 10 BAR
Part Numbers
-76F to 221F
(-60C to 105C)

Thread
Type
& Size

Ex-e
Nylon Glands

Ex-e Multi-Hole &


Romex Glands

Ex-e Nickel Plated Brass &


Stainless Steel Glands
*

(Low Temp. - Nylon Spline)

(PVDF Spline)

Inches (mm)

CC09NA-MX-D
CC09NR-MX-D
CC16NA-MX-D
CC16NR-MX-D
CC21NA-MX-D
CC21NR-MX-D
CC29NA-MX-D
CC29NR-MX-D
CC29LA-MX-D
CC29LR-MX-D
CC36NA-MX-D
CC36NR-MX-D

CD09NA-RX-D
CD09NR-RX-D
CD16NA-RX-D
CD16NR-RX-D
CD21NA-RX-D
CD21NR-RX-D
-

.20 - .39 (5 - 10)


.12 - .28 (3 - 7)
.39 - .55 (10 - 14)
.28 - .47 (7 - 12)
.51 - .71 (13 - 18)
.35 - .63 (9 - 16)
.71 - .98 (18 - 25)
.55 - .79 (14 - 20)
.87 - 1.26 (22 - 32)
.79 - 1.02 (20 - 26)
.87 - 1.26 (22 - 32)
.79 - 1.02 (20 - 26)

CC12MA-MX-D
CC12MR-MX-D
CC17MA-MX-D
CC17MR-MX-D
CC22MA-MX-D
CC22MR-MX-D
CC25MA-MX-D
CC25MR-MX-D
CC32MA-MX-D
CC32MR-MX-D
CC40MA-MX-D
CC40MR-MX-D

CD12MA-RX-D
CD12MR-RX-D
CD17MA-RX-D
CD17MR-RX-D
CD22MA-RX-D
CD22MR-RX-D
CD25MA-RX-D
CD25MR-RX-D
CD32MA-RX-D
CD32MR-RX-D
CD40MA-RX-D
CD40MR-RX-D

.12 - .26 (3 - 6.5)


.08 - .20 (2 - 5)
.20 - .39 (5 - 10)
.12 - .28 (3 - 7)
.39 - .55 (10 - 14)
.28 - .47 (7 - 12)
.51 - .71 (13 - 18)
.35 - .63 (9 - 16)
.71 - .98 (18 - 25)
.55 - .79 (14 - 20)
.87 - 1.26 (22 - 32)
.79 - 1.02 (20 - 26)

Dimensions in Inches (mm)


A

Clearance
Hole

Body
Length

Thread
Length

Wrench
Flats

Page 59
for Thread
Specs

+ .01
(+.25 mm)

(Dome)

3/8 NPT

.68 (17.2)

.87 (22)

.63 (16)

.79 (20)

1/2 NPT

.83 (21.1)

.98 (25)

.79 (20)

.94 (24)

3/4 NPT

1.05 (26.7)

1.04 (26.5)

.81 (20.5)

1.18 (30)

1 NPT

1.31 (33.4)

1.26 (32)

.98 (25)

1.57 (40)

1-1/4 NPT

1.65 (41.9)

1.52 (38.5)

1.02 (26)

1.97 (50)

1-1/2 NPT

1.92 (48.7)

1.52 (38.5)

1.04 (26.5)

1.97 (50)

M12 x 1.5

.47 (12)

.75 (19)

.63 (16)

.55 (14)

M16 x 1.5

.63 (16)

.87 (22)

.63 (16)

.79 (20)

M20 x 1.5

.79 (20)

.98 (25)

.63 (16)

.94 (24)

M25 x 1.5

.98 (25)

1.04 (26.5)

.63 (16)

1.18 (30)

M32 x 1.5

1.26 (32)

1.26 (32)

.63 (16)

1.57 (40)

M40 x 1.5

1.57 (40)

1.52 (38.5)

.63 (16)

1.97 (50)

-60C

applies only to MX-D Nylon spline style cable glands

(MX-D)

FPM
O-Rings

FPM
Inserts

Nylon Spline

(RX-D)

PVDF Spline

Ex-e / Ex-d
Accessories

Technical
Information

Cable Range

-4F to 266F
(-20C to 130C)

Ex-e Conduit &


Fitting Systems

Ex-e EMI / RFI Nickel


Plated Brass Glands

Nickel Plated Brass Cable Glands - Low Temperature


NPT / Metric - ATEX / IECEx / Ex-d (Flameproof)

II 2G 1D Ex d IIC

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Ex-d EXIOS
Cable Glands

ATEX

Longer Threads: All Ex-d EXIOS & Standard style cable glands have longer
threads to meet the new five thread engagement requirement. Metric threads require
eight threads of engagement. Manufactured according to EN 60079-1 or IEC
60079-1, which addresses the ANSI B1.20.1./1.20.3. ANSI. NPT cable glands do not
come with an O-Ring.

14

www.sealconex.com

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Suggested Clearance
Hole for Non-Threaded
Mounting

II 2G 1D Ex d IIC

Nickel Plated Brass Cable Gland w/ Clamp - Low Temp.


NPT / Metric - ATEX / IECEx / Ex-d (Flameproof)

Ex-d EXIOS
Cable Glands

ATEX

For Non-Armored Cable


Part Numbers

Cable Range

Thread
Type
& Size

-76F to 221F
(-60C to 105C)

-60C
Page 59
for Thread
Specs

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Ex-d/Ex-e Nickel Plated Brass


Brass, Cable Glands for Hazardous Duty Locations, with Clamp
Clamp, Nylon Spline with FPM Insert, IP 68/69K, 10 BAR
Dimensions in Inches (mm)
A

Clearance
Hole

Body
Length

Thread
Length

Wrench
Flats

+ .01
(+.25 mm)

CC09NA-EZ-D
CC16NA-EZ-D
CC21NA-EZ-D
CC29NA-EZ-D
CC29LA-EZ-D
CC36NA-EZ-D

.20 - .39 (5 - 10)


.39 - .55 (10 - 14)
.51 - .71 (13 - 18)
.71 - .98 (18 - 25)
.87 - 1.26 (22 - 32)
.87 - 1.26 (22 - 32)

3/8 NPT
1/2 NPT
3/4 NPT
1 NPT
1 1/4 NPT
1 1/2 NPT

.68 (17.2)
.83 (21.1)
1.05 (26.7)
1.35 (34.3)
1.65 (41.9)
1.92 (48.7)

(Clamp)
1.18 (30)
1.34 (34)
1.50 (38)
1.73 (44)
2.03 (51.5)
2.03 (51.5)

.63 (16)
.79 (20)
.81 (20.5)
.98 (25)
1.02 (26)
1.04 (26.5)

.79 (20)
.94 (24)
1.18 (30)
1.57 (40)
1.97 (50)
1.97 (50)

CC12MA-EZ-D
CC17MA-EZ-D
CC22MA-EZ-D
CC25MA-EZ-D
CC32MA-EZ-D
CC40MA-EZ-D

.12 - .26 (3 - 6.5)


.20 - .39 (5 - 10)
.39 - .55 (10 - 14)
.51 - .71 (13 - 18)
.71 - .98 (18 - 25)
.87 - 1.26 (22 - 32)

M12 x 1.5
M16 x 1.5
M20 x 1.5
M25 x 1.5
M32 x 1.5
M40 x 1.5

.47 (12)
.63 (16)
.79 (20)
.98 (25)
1.26 (32)
1.57 (40)

1.02 (26)
1.18 (30)
1.34 (34)
1.50 (38)
1.73 (44)
2.03 (51.5)

.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)

.55 (14)
.79 (20)
.94 (24)
1.18 (30)
1.57 (40)
1.97 (50)

Ex-e Multi-Hole &


Romex Glands

Inches (mm)

Ex-e
Nylon Glands

(Low Temp. - Nylon Spline)

Ex-e Nickel Plated Brass &


Stainless Steel Glands

FPM
O-Ring

Nylon Spline
Clamp
(MZ)

Suggested Clearance
Hole for Non-Threaded
Mounting

FPM
Form Seal Insert

Ex-e EMI / RFI Nickel


Plated Brass Glands

(EZ-D)

Nickel Plated Brass with MZ Clamps


Extra Pull-out Resistance
Liquid Tight to IP68/NEMA 6

Ex-e Conduit &


Fitting Systems

www.sealconex.com

15

Technical
Information

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Ex-e / Ex-d
Accessories

Longer Threads: All Ex-d Standard style cable glands have longer threads to
meet the five thread engagement requirement. Metric threads require eight threads
of engagement. Manufactured according to EN 60079-1 or IEC 60079-1, which
addresses the ANSI B1.20.1./1.20.3. ANSI. NPT cable glands do not come with
an O-Ring.

II 2G 1D Ex d IIC

For Non-Armored Cable

Ex-d/Ex-e (316L) Stainless Steel (INOX) Cable Glands for Hazardous Duty Locations, Nylon/PVDF Spline with FPM Inserts
Inserts, IP 68/69K, 10 BAR

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Ex-d EXIOS
Cable Glands

ATEX

(316L) Stainless Steel Cable Glands - Low Temp.


NPT / Metric - ATEX / IECEx / Ex-d (Flameproof)

Part Numbers
-76F to 221F
(-60C to 105C)

Cable Range

Thread
Type
& Size

-4F to 266F
(-20C to 130C)

Clearance
Hole

Body
Length

Thread
Length

Wrench
Flats

Page 59
for Thread
Specs

+ .01
(+.25 mm)

(Dome)

3/8 NPT

.68 (17.2)

.87 (22)

.63 (16)

.79 (20)

1/2 NPT

.83 (21.1)

.98 (25)

.79 (20)

.94 (24)

3/4 NPT

1.05 (26.7)

1.04 (26.5)

.81 (20.5)

1.18 (30)

M12 x 1.5

.47 (12)

.75 (19)

.63 (16)

.55 (14)

M16 x 1.5

.63 (16)

.87 (22)

.63 (16)

.79 (20)

M20 x 1.5

.79 (20)

.98 (25)

.63 (16)

.94 (24)

M25 x 1.5

.98 (25)

1.04 (26.5)

.63 (16)

1.18 (30)

M32 x 1.5

1.26 (32)

1.26 (32)

.63 (16)

1.57 (40)

M40 x 1.5

1.57 (40)

1.52 (38.5)

.63 (16)

1.97 (50)

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Ex-e Multi-Hole &


Romex Glands

Ex-e
Nylon Glands

-60C

(Low Temp. - Nylon Spline)

(PVDF Spline)

Inches (mm)

CC09NA-6X-D
CC09NR-6X-D
CC16NA-6X-D
CC16NR-6X-D
CC21NA-6X-D
CC21NR-6X-D

CD09NA-6VX-D
CD09NR-6VX-D
CD16NA-6VX-D
CD16NR-6VX-D
CD21NA-6VX-D
CD21NR-6VX-D

.20 - .39 (5 - 10)


.12 - .28 (3 - 7)
.39 - .55 (10 - 14)
.28 - .47 (7 - 12)
.51 - .71 (13 - 18)
.35 - .63 (9 - 16)

CC12MA-6X-D
CC12MR-6X-D
CC17MA-6X-D
CC17MR-6X-D
CC22MA-6X-D
CC22MR-6X-D
CC25MA-6X-D
CC25MR-6X-D
CC32MA-6X-D
CC32MR-6X-D
CC40MA-6X-D
CC40MR-6X-D

CD12MA-6VX-D
CD12MR-6VX-D
CD17MA-6VX-D
CD17MR-6VX-D
CD22MA-6VX-D
CD22MR-6VX-D
CD25MA-6VX-D
CD25MR-6VX-D
CD32MA-6VX-D
CD32MR-6VX-D
CD40MA-6VX-D
CD40MR-6VX-D

.12 - .26 (3 - 6.5)


.08 - .20 (2 - 5)
.20 - .39 (5 - 10)
.12 - .28 (3 - 7)
.39 - .55 (10 - 14)
.28 - .47 (7 - 12)
.51 - .71 (13 - 18)
.35 - .63 (9 - 16)
.71 - .98 (18 - 25)
.55 - .79 (14 - 20)
.87 - 1.26 (22 - 32)
.79 - 1.02 (20 - 26)

Dimensions in Inches (mm)

(6X-D)

Ex-e EMI / RFI Nickel


Plated Brass Glands

Nylon Spline
FPM Form
Seal Inserts
PVDF Spline

(6VX-D)

Ex-e Conduit &


Fitting Systems

FPM
O-Rings

Technical
Information

Ex-e / Ex-d
Accessories

Longer Threads: All Ex-d EXIOS & Standard style cable glands have longer
threads to meet the new five thread engagement requirement. Metric threads require
eight threads of engagement. Manufactured according to EN 60079-1 or IEC
60079-1, which addresses the ANSI B1.20.1./1.20.3. ANSI. NPT cable glands do not
come with an O-Ring.

16

www.sealconex.com

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Suggested Clearance
Hole for Non-Threaded
Mounting

For Non-Armored Cable


Technical Description

Ex-e Cable Glands for non-armored cable - Cost Saving Option!


International Approvals - cUS/ATEX/IECEx, UL/UR, CE, CSA, Gost and German Lloyd!
Ref. Standards
NEMA 4x & 6 (IP 67 & 68) - Liquid Tight - Submersible to 300 ft!
DIN EN 60079-0
IP 69K rated - Ideal in splash or hose down applications!
DIN EN 60079-7
Patented Form Seal allows 150 PSIG (10 BAR) rating - Highest in Industry!
V0 flame rating according to UL 94 Halogen & Phosphorous Free non toxic!
UV/Ozone stable Black Nylon UL f1 (746C) Ideal Outdoors (RTU/SCADA)!
Concentric O-Ring Groove for some NEMA applications!
Safety Ratchet - Prevents Dome top from coming loose under vibration!
Large selection in Black, Gray & Blue - Cable Range from .08 - 1.73 (2 - 44 mm)
Non-Corrosive - Resistant to salt water, weak acids, weak alkalis, alcohol, esters, ketones,
ether, gasoline, mineral, animal & vegetable oil
RoHS & Deca BDE - Environmentally Compliant!

Ex-e
Nylon Glands

E103997
104031
0 UE11

Ex-d Nickel Plated Brass &


Stainless Steel Glands

UL/UR
CSA
CAGE

Ex-d EXIOS
Cable Glands

Nylon Cable Glands - Introduction


cUS / ATEX / IECEx / Ex-e

Blue
(RAL 5012)

Ex-e Multi-Hole &


Romex Glands

Your One Stop Solution For All Cable & Wire Accessories!
Pull-out Resistance & Cable Protection
Overlapping clamping splines apply a concentric force, preventing
the form seal from being pulled out of the fitting. This ensures pull-out
protection without damage to the cable.

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Durable - Rugged Construction!


The self locking ACME thread prevents
the dome nut from dissengaging under
extreme lateral force.

Liquid Tight

Ex-e EMI / RFI Nickel


Plated Brass Glands

Molded groove for standard O-Ring. An


O-Ring results in a secure liquid tight
seal between fitting and housing.
All fittings come with an O-Ring!

Fiber Reinforced Nylon


Time Saving Installation
Simply push the cable through cable glands - Tighten dome nut - Done!
No disassembly of the cable glands required.

Our BXA Cable Glands are built


to withstand the Highest Impact
Resistance! (See pages 18-19)

Ex-e Conduit &


Fitting Systems

Multi-Hole & Romex Form Seal Inserts

ATEX

II 2G 1D

Ex-e / Ex-d
Accessories

Nylon CP Clamps
(High Pull-out Resistance)

UL f1 (746C)

UL746C
f1

800-456-9012

Dimensions, specifications and certifications may be changed without prior notice.

www.sealconex.com

17

Technical
Information

Unique Solution to prevent excessive


cable torque.

All Black Nylon Dome Cable Glands,


are made with UV / Ozone Stable
material.

Ex-d EXIOS
Cable Glands

DIN EN 60079-0: 2012


IEC 60079-0: 2011
II 2G Ex e IIC Gb / II 1D Ex ta IIIC Da

For Non-Armored Cable

Fiber Reinforced Nylon


Nylon, Cable Glands for Hazardous Duty Locations, Black
Black, V0, UL94, NEMA 6, IP 68, 150 PSIG, 10 BAR, DIN EN 60079-0: 2012
Part Numbers
-4F to 185F
(-20C to 85C)
UL746C
f1

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Ex-e Multi-Hole &


Romex Glands

Ex-e
Nylon Glands

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Fiber Reinforced Nylon - Black Cable Glands


Metric / Metric Elongated - cUS / ATEX / IECEx / Ex-e

ATEX

Cable Range

-4F to 185F
(-20C to 85C)

UL746C
f1

Thread
Type
& Size

F1/F

Clearance
Hole

Body
Length

Thread
Length

Thread
Length

Wrench
Flats

Page 59
for Thread
Specs

+ .01
(+.25 mm)

(Dome)

(Standard)

(Elongated)

M12 x 1.5

.47 (12)

.83 (21)

.31 (8)

.59 (15)

.59 (15)

M16 x 1.5

.63 (16)

.87 (22)

.31 (8)

.59 (15)

.75 (19)

M16 x 1.5

.63 (16)

.98 (25)

.31 (8)

.59 (15)

.87 (22)

M20 x 1.5

.79 (20)

1.06 (27)

.35 (9)

.59 (15)

.94 (24)

M20 x 1.5

.79 (20)

1.10 (28)

.35 (9)

.59 (15)

1.06 (27)

M25 x 1.5

.98 (25)

1.22 (31)

.43 (11)

.59 (15)

1.30 (33)

M32 x 1.5

1.26 (32)

1.53 (39)

.43 (11)

.59 (15)

1.65 (42)

M40 x 1.5

1.57 (40)

1.88 (48)

.51 (13)

.71 (18)

2.09 (53)

M50 x 1.5

1.97 (50)

1.93 (49)

.51 (13)

.71 (18)

2.36 (60)

M63 x 1.5

2.48 (63)

1.93 (49)

.55 (14)

.71 (18)

2.56 (65) /
2.68 (68)

(Standard)

(Elongated)

Inches (mm)

CD12MA-BXA
CD12MR-BXA
CD16MA-BXA
CD16MR-BXA
CD17MA-BXA
CD17MR-BXA
CD20MA-BXA
CD20MR-BXA
CD22MA-BXA
CD22MR-BXA
CD25MA-BXA
CD25MR-BXA
CD32MA-BXA
CD32MR-BXA
CD40MA-BXA
CD40MR-BXA
CD50MA-BXA
CD50MR-BXA
CD63MA-BXA
CD63MR-BXA

CD12DA-BXA
CD12DR-BXA
CD16DA-BXA
CD16DR-BXA
CD17DA-BXA
CD17DR-BXA
CD20DA-BXA
CD20DR-BXA
CD22DA-BXA
CD22DR-BXA
CD25DA-BXA
CD25DR-BXA
CD32DA-BXA
CD32DR-BXA
CD40DA-BXA
CD40DR-BXA
CD50DA-BXA
CD50DR-BXA
CD63DA-BXA
CD63DR-BXA

.12 - .26 (3 - 6.5)


.08 - .20 (2 - 5)
.16 - .31 (4 - 8)
.12 - .24 (3 - 6)
.20 - .39 (5 - 10)
.12 - .28 (3 - 7)
.26 - .47 (6.5 - 12)
.20 - .35 (5 - 9)
.39 - .55 (10 - 14)
.28 - .47 (7 - 12)
.51 - .71 (13 - 18)
.35 - .63 (9 - 16)
.71 - .98 (18 - 25)
.51 - .79 (13 - 20)
.87 - 1.26 (22 - 32)
.79 - 1.02 (20 - 26)
1.26 - 1.50 (32 - 38)
.98 - 1.22 (25 - 31)
1.46 - 1.73 (37 - 44)
1.14 - 1.38 (29 - 35)

Ex-e EMI / RFI Nickel


Plated Brass Glands

(BXA)

Dome Nut

Spline

Buna-N
O-Ring (Included)

The Fiber Reinforced Nylon Cable Gland


has been designed for applications in electrical
equipment, which require Ex-e and Ex-ta types
of protection according to the latest standards
in Class I, Div 2, Class I, Div 1, Zones 1, 2, 20,
21, 22
EC-Type Examination Certificate:
BVS 14 ATEX E 025 X
IECEx Certificate of Conformity:
IECEx BVS 14.0020X
According to the latest EN Standards:
EN 60079-0:2012
IEC 60079-0:2011
EN 60079-7:2007
IEC 60079-7:2007
EN 60079-31:2009
IEC 60079-31:2008

Suggested Clearance
Hole for Non-Threaded
Mounting

Technical
Information

Ex-e / Ex-d
Accessories

Ex-e Conduit &


Fitting Systems

Buna-N Form
Seal Insert

Dimensions in Inches (mm)

Elongated Thread is recommended where the Cable Gland


has to pass through a thick wall or the application needs
Extra Thread Length.
18

www.sealconex.com

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

DIN EN 60079-0: 2012


EC 60079-0: 2011
II 2G Ex e IIC Gb / II 1D Ex ta IIIC Da

Ex-d EXIOS
Cable Glands

Fiber Reinforced Nylon - Black Cable Glands


NPT Threads - cUS / ATEX / IECEx / Ex-e

ATEX

For Non-Armored Cable

Part Numbers

Cable Range

-4F to 185F
(-20C to 85C)
UL746C
f1

Thread Type
& Size

Dimensions in Inches (mm)


C

F1/F

Clearance
Hole

Body
Length

Thread
Length

Wrench
Flats

Inches (mm)

+ .01
(+.25 mm)

(Dome)

CD09NA-BXA
CD09NR-BXA
CD13NA-BXA
CD13NR-BXA
CD16NA-BXA
CD16NR-BXA
CD21NA-BXA
CD21NR-BXA
CD29NA-BXA
CD29NR-BXA
CD29LA-BXA
CD29LR-BXA
CD36NA-BXA
CD36NR-BXA

.16 - .31 (4 - 8)
.08 - .24 (2 - 6)
.24 - .47 (6 - 12)
.20 - .35 (5 - 9)
.39 - .55 (10 - 14)
.28 - .47 (7 - 12)
.51 - .71 (13 - 18)
.35 - .63 (9 - 16)
.71 - .98 (18 - 25)
.51 - .79 (13 - 20)
.71 - .98 (18 - 25)
.51 - .79 (13 - 20)
.87 - 1.26 (22 - 32)
.79 - 1.02 (20 - 26)

(Standard)

3/8 NPT

.68 (17.2)

.87 (22)

.59 (15)

.74 (19) / .87 (22)

1/2 NPT

.83 (21.1)

1.06 (27)

.51 (13)

.95 (24)

1/2 NPT

.83 (21.1)

1.10 (28)

.51 (13)

1.06 (27)

3/4 NPT

1.05 (26.7)

1.22 (31)

.55 (14)

1.29 (33)

1 NPT

1.35 (34.3)

1.53 (39)

.75 (19)

1.65 (42)

1-1/4 NPT

1.65 (41.9)

1.53 (39)

.63 (16)

1.62 (42)/1.81 (46)

1-1/2 NPT

1.92 (48.7)

1.89 (48)

.79 (20)

2.09 (53)

Page 59
for Thread
Specs

Ex-e Multi-Hole &


Romex Glands

Ex-e
Nylon Glands

(Standard)

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Fiber Reinforced Nylon


Nylon, Cable Glands for Hazardous Duty Locations, Black
Black, V0, UL94, NEMA 6, IP 68, 150 PSIG, 10 BAR, DIN EN 60079-0: 2012

*Note: UL f1 (746C) rating applies to Black Nylon Fittings only.

Ex-e Nickel Plated Brass &


Stainless Steel Glands

(BXA)

Dome Nut

Buna-N Form
Seal Insert

Spline

Buna-N
O-Ring (Included)

Suggested Clearance
Hole for Non-Threaded
Mounting

Ex-e EMI / RFI Nickel


Plated Brass Glands

This product has been specially developed for the


ignition protection category Ex-e, passing all of the
new norms and withstanding a high degree of shock
resistance with its fiber reinforced body.

19

Technical
Information

www.sealconex.com

Ex-e / Ex-d
Accessories

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Ex-e Conduit &


Fitting Systems

Halogen-Free
Flame rating V0 according to UL 94
Protection IP 68 10 bar according to DIN EN 60529
7 Joule Impact Resistant
Anti - vibration dome nut
Wide clamping range
Applicable up to +85C (185F)
Abrasion resistant labeling
O-Ring standard
Applicable in Class, Div & Zone areas
No additional mechanical protection of the gland necessary

Ex-d EXIOS
Cable Glands

Nylon - Black / Blue Cable Glands - Metric / Metric


Elong. - UL / CSA / ATEX / IECEx / Inmetro / Ex-e

Blue
Nylon
Nylon, Cable Glands for Hazardous Duty Locations, Black
Black(RAL 9005)/Blue(RAL
5012), V0, UL94, UL f1 (746C), NEMA 6, IP 68/69K, 150 PSIG, 10 BAR
Part Numbers
-4F to 203F
(-20C to 95C)
UL746C
f1

Ex-e Multi-Hole &


Romex Glands

Cable Range

-4F to 203F
(-20C to 95C)

UL746C
f1

Thread
Type
& Size

Dimensions in Inches (mm)


A

F1/F

Clearance
Hole

Body
Length

Thread
Length

Thread
Length

Wrench
Flats

Page 59
for Thread
Specs

+ .01
(+.25 mm)

(Dome)

(Standard)

(Elongated)

M12 x 1.5

.47 (12)

.83 (21)

.31 (8)

.59 (15)

.59 (15)

M16 x 1.5

.63 (16)

.87 (22)

.31 (8)

.59 (15)

.75 (19)

M16 x 1.5

.63 (16)

.98 (25)

.31 (8)

.59 (15)

.87 (22)

M20 x 1.5

.79 (20)

1.06 (27)

.35 (9)

.59 (15)

.94 (24)

M20 x 1.5

.79 (20)

1.10 (28)

.35 (9)

.59 (15)

1.06 (27)

M25 x 1.5

.98 (25)

1.22 (31)

.43 (11)

.59 (15)

1.30 (33)

M32 x 1.5

1.26 (32)

1.53 (39)

.43 (11)

.59 (15)

1.65 (42)

M40 x 1.5

1.57 (40)

1.88 (48)

.51 (13)

.71 (18)

2.09 (53)

M50 x 1.5

1.97 (50)

1.93 (49)

.51 (13)

.71 (18)

2.36 (60)

M63 x 1.5

2.48 (63)

1.93 (49)

.55 (14)

.71 (18)

2.56 (65) /
2.68 (68)

(Standard)

(Elongated)

Inches (mm)

CD12MA-BX
CD12MR-BX
CD16MA-BX
CD16MR-BX
CD17MA-BX
CD17MR-BX
CD20MA-BX
CD20MR-BX
CD22MA-BX
CD22MR-BX
CD25MA-BX
CD25MR-BX
CD32MA-BX
CD32MR-BX
CD40MA-BX
CD40MR-BX
CD50MA-BX
CD50MR-BX
CD63MA-BX
CD63MR-BX

CD12DA-BX
CD12DR-BX
CD16DA-BX
CD16DR-BX
CD17DA-BX
CD17DR-BX
CD20DA-BX
CD20DR-BX
CD22DA-BX
CD22DR-BX
CD25DA-BX
CD25DR-BX
CD32DA-BX
CD32DR-BX
CD40DA-BX
CD40DR-BX
CD50DA-BX
CD50DR-BX
CD63DA-BX
CD63DR-BX

.12 - .26 (3 - 6.5)


.08 - .20 (2 - 5)
.16 - .31 (4 - 8)
.12 - .24 (3 - 6)
.20 - .39 (5 - 10)
.12 - .28 (3 - 7)
.26 - .47 (6.5 - 12)
.20 - .35 (5 - 9)
.39 - .55 (10 - 14)
.28 - .47 (7 - 12)
.51 - .71 (13 - 18)
.35 - .63 (9 - 16)
.71 - .98 (18 - 25)
.51 - .79 (13 - 20)
.87 - 1.26 (22 - 32)
.79 - 1.02 (20 - 26)
1.26 - 1.50 (32 - 38)
.98 - 1.22 (25 - 31)
1.46 - 1.73 (37 - 44)
1.14 - 1.38 (29 - 35)

*Note: UL f1 (746C) rating applies to Black Nylon Fittings only.

*
(BX)

Ex-e EMI / RFI Nickel


Plated Brass Glands

Ex-e Nickel Plated Brass &


Stainless Steel Glands

II 2G 1D

For Non-Armored Cable

Ex-e
Nylon Glands

Ex-d Nickel Plated Brass &


Stainless Steel Glands

ATEX

Dome Nut

Buna-N Form
Seal Insert

Spline

Buna-N
O-Ring (Included)

When ordering the Blue


version of this product
please substitute the UX
for BX! (e.g.- CD20MR-UX)

Ex-e Conduit &


Fitting Systems

(UX)

Buna-N
O-Ring (Included)

Ex-e / Ex-d
Accessories

Technical
Information

UL746C
f1

20

www.sealconex.com

Suggested Clearance
Hole for Non-Threaded
Mounting

Elongated Thread is recommended where the Cable Gland


has to pass through a thick wall or the application just
needs the Extra Thread Length.

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

II 2G 1D

Nylon - Black / Blue Cable Glands - PG / PG Elong.


UL / CSA / ATEX / IECEx / Inmetro / Ex-e

Ex-d EXIOS
Cable Glands

ATEX

For Non-Armored Cable


Part Numbers
-4F to 203F
(-20C to 95C)
UL746C
f1

Cable Range

Thread
Type
& Size

-4F to 203F
(-20C to 95C)

UL746C
f1

Dimensions in Inches (mm)


D

Clearance
Hole

Body
Length

Thread
Length

Thread
Length

Wrench
Flats

Page 59
for Thread
Specs

+ .01
(+.25 mm)

(Dome)

(Standard)

(Elongated)

PG 7

.49 (12.5)

.83 (21)

.31 (8)

.59 (15)

.59 (15)

PG 9

.60 (15.2)

.87 (22)

.31 (8)

.59 (15)

.75 (19)

PG 11

.73 (18.5)

.98 (25)

.31 (8)

.59 (15)

.87 (22)

PG 13

.80 (20.3)

1.06 (27)

.35 (9)

.59 (15)

.94 (24)

PG 16

.89 (22.5)

1.10 (28)

.39 (10)

.59 (15)

1.06 (27)

PG 21

1.12 (28.4)

1.22 (31)

.43 (11)

.59 (15)

1.30 (33)

PG 29

1.47 (37.3)

1.53 (39)

.43 (11)

.59 (15)

1.65 (42)

PG 36

1.85 (47)

1.88 (48)

.51 (13)

.71 (18)

2.09 (53)

PG 42

2.13 (54.1)

1.93 (49)

.51 (13)

.71 (18)

2.36 (60)

PG 48

2.34 (59.4)

1.93 (49)

.55 (14)

.71 (18)

2.56 (65)

(Standard)

(Elongated)

Inches (mm)

CD07AA-BX
CD07AR-BX
CD09AA-BX
CD09AR-BX
CD11AA-BX
CD11AR-BX
CD13AA-BX
CD13AR-BX
CD16AA-BX
CD16AR-BX
CD21AA-BX
CD21AR-BX
CD29AA-BX
CD29AR-BX
CD36AA-BX
CD36AR-BX
CD42AA-BX
CD42AR-BX
CD48AA-BX
CD48AR-BX

CD07CA-BX
CD07CR-BX
CD09CA-BX
CD09CR-BX
CD11CA-BX
CD11CR-BX
CD13CA-BX
CD13CR-BX
CD16CA-BX
CD16CR-BX
CD21CA-BX
CD21CR-BX
CD29CA-BX
CD29CR-BX
CD36CA-BX
CD36CR-BX
CD42CA-BX
CD42CR-BX
CD48CA-BX
CD48CR-BX

.12 - .26 (3 - 6.5)


.08 - .20 (2 - 5)
.16 - .31 (4 - 8)
.12 - .24 (3 - 6)
.20 - .39 (5 - 10)
.12 - .28 (3 - 7)
.26 - .47 (6.5 - 12)
.20 - .35 (5 - 9)
.39 - .55 (10 - 14)
.28 - .47 (7 - 12)
.51 - .71 (13 - 18)
.35 - .63 (9 - 16)
.71 - .98 (18 - 25)
.51 - .79 (13 - 20)
.87 - 1.26 (22 - 32)
.79 - 1.02 (20 - 26)
1.26 - 1.50 (32 - 38)
.98 - 1.22 (25 - 31)
1.46 - 1.73 (37 - 44)
1.14 - 1.38 (29 - 35)

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Ex-e Multi-Hole &


Romex Glands

Ex-e
Nylon Glands

*Note: UL f1 (746C) rating applies to Black Nylon Fittings only.

(BX)

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Blue
Nylon
Nylon, Cable Glands for Hazardous Duty Locations, Black
Black(RAL 9005)/Blue(RAL
5012), V0, UL94, UL f1 (746C), NEMA 6, IP 68/69K, 150 PSIG, 10 BAR

UL746C
f1
Buna-N Form
Seal Insert

Spline

Buna-N
O-Ring (Included)

Ex-e EMI / RFI Nickel


Plated Brass Glands

Dome Nut

When ordering the Blue


version of this product
please substitute the UX
for BX! (e.g.- CD20CR-UX)

Ex-e Conduit &


Fitting Systems

(UX)

Elongated Thread is recommended where the Cable Gland


has to pass through a thick wall or the application just
needs the Extra Thread Length.

www.sealconex.com

21

Technical
Information

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Ex-e / Ex-d
Accessories

Suggested Clearance
Hole for Non-Threaded
Mounting

Ex-d EXIOS
Cable Glands

Nylon - Black / Gray / Blue Cable Glands - NPT


UL / CSA / ATEX / IECEx / Inmetro / Ex-e

Nylon Cable Glands for Hazardous Duty Locations, Black (RAL 9005) / Gray (RAL 7035) / Blue (RAL 5012)
Nylon,
V0, UL94, UL f1 (746C), NEMA 6, IP 68/69K, 150 PSIG, 10 BAR
Part Numbers

Part Numbers

-4F to 203F
(-20C to 95C)

-4F to 203F
(-20C to 95C)

UL746C
f1

(Standard)

CD09NA-BX
CD09NR-BX
CD13NA-BX
CD13NR-BX
CD16NA-BX
CD16NR-BX
CD21NA-BX
CD21NR-BX
CD29NA-BX
CD29NR-BX
CD29LA-BX
CD29LR-BX
CD36NA-BX
CD36NR-BX

Ex-e Multi-Hole &


Romex Glands

Cable Range

Thread Type
& Size

Dimensions in Inches (mm)


A

F1/F

Clearance
Hole

Body
Length

Thread
Length

Wrench
Flats

Page 59
for Thread
Specs

+ .01
(+.25 mm)

(Dome)

(Standard)

3/8 NPT

.68 (17.2)

.87 (22)

.59 (15)

.74 (19) / .87 (22)

1/2 NPT

.83 (21.1)

1.06 (27)

.51 (13)

.95 (24)

1/2 NPT

.83 (21.1)

1.10 (28)

.51 (13)

1.06 (27)

3/4 NPT

1.05 (26.7)

1.22 (31)

.55 (14)

1.29 (33)

1 NPT

1.35 (34.3)

1.53 (39)

.75 (19)

1.65 (42)

1-1/4 NPT

1.65 (41.9)

1.53 (39)

.63 (16)

1.62 (42)/1.81 (46)

1-1/2 NPT

1.92 (48.7)

1.89 (48)

.79 (20)

2.09 (53)

(Standard)

Inches (mm)

CD09NA-GX
CD09NR-GX
CD13NA-GX
CD13NR-GX
CD16NA-GX
CD16NR-GX
CD21NA-GX
CD21NR-GX
CD29NA-GX
CD29NR-GX
CD29LA-GX
CD29LR-GX
CD36NA-GX
CD36NR-GX

.16 - .31 (4 - 8)
.08 - .24 (2 - 6)
.26 - .47 (6.5 - 12)
.20 - .35 (5 - 9)
.39 - .55 (10 - 14)
.28 - .47 (7 - 12)
.51 - .71 (13 - 18)
.35 - .63 (9 - 16)
.71 - .98 (18 - 25)
.51 - .79 (13 - 20)
.71 - .98 (18 - 25)
.51 - .79 (13 - 20)
.87 - 1.26 (22 - 32)
.79 - 1.02 (20 - 26)

*Note: UL f1 (746C) rating applies to Black Nylon Fittings only.

UL746C
f1
(BX)
A

Dome Nut

Buna-N Form
Seal Insert

Suggested Clearance
Hole for Non-Threaded
Mounting

Buna-N
O-Ring (Included)

Spline

Ex-e EMI / RFI Nickel


Plated Brass Glands

Ex-e Nickel Plated Brass &


Stainless Steel Glands

II 2G 1D

For Non-Armored Cable

Ex-e
Nylon Glands

Ex-d Nickel Plated Brass &


Stainless Steel Glands

ATEX

(GX)

UL746C
f1

Ex-e Conduit &


Fitting Systems

When ordering the Blue version of this product please


substitute UX for BX or GX! (e.g.- CD16NR-UX)

Technical
Information

Ex-e / Ex-d
Accessories

(UX)

Dome Nut

22

Buna-N Form
Seal Insert

www.sealconex.com

Spline

Buna-N
O-Ring (Included)

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Buna-N
O-Ring (Included)

II 2G 1D

Nylon - Gray Cable Glands - Metric / Metric Elong.


UL / CSA / ATEX / IECEx / Inmetro / Ex-e

Ex-d EXIOS
Cable Glands

ATEX

For Non-Armored Cable


Part Numbers
-4F to 203F
(-20C to 95C)

Cable Range

-4F to 203F
(-20C to 95C)

CD12MA-GX
CD12MR-GX
CD16MA-GX
CD16MR-GX
CD17MA-GX
CD17MR-GX
CD20MA-GX
CD20MR-GX
CD22MA-GX
CD22MR-GX
CD25MA-GX
CD25MR-GX
CD32MA-GX
CD32MR-GX
CD40MA-GX
CD40MR-GX
CD50MA-GX
CD50MR-GX
CD63MA-GX
CD63MR-GX

CD12DA-GX
CD12DR-GX
CD16DA-GX
CD16DR-GX
CD17DA-GX
CD17DR-GX
CD20DA-GX
CD20DR-GX
CD22DA-GX
CD22DR-GX
CD25DA-GX
CD25DR-GX
CD32DA-GX
CD32DR-GX
CD40DA-GX
CD40DR-GX
CD50DA-GX
CD50DR-GX
CD63DA-GX
CD63DR-GX

.12 - .26 (3 - 6.5)


.08 - .20 (2 - 5)
.16 - .31 (4 - 8)
.12 - .24 (3 - 6)
.20 - .39 (5 - 10)
.12 - .28 (3 - 7)
.26 - .47 (6.5 - 12)
.20 - .35 (5 - 9)
.39 - .55 (10 - 14)
.28 - .47 (7 - 12)
.51 - .71 (13 - 18)
.35 - .63 (9 - 16)
.71 - .98 (18 - 25)
.51 - .79 (13 - 20)
.87 - 1.26 (22 - 32)
.79 - 1.02 (20 - 26)
1.26 - 1.50 (32 - 38)
.98 - 1.22 (25 - 31)
1.46 - 1.73 (37 - 44)
1.14 - 1.38 (29 - 35)

F1/F

Clearance
Hole

Body
Length

Thread
Length

Thread
Length

Wrench
Flats

Page 59
for Thread
Specs

+ .01
(+.25 mm)

(Dome)

(Standard)

(Elongated)

M12 x 1.5

.47 (12)

.83 (21)

.31 (8)

.59 (15)

.59 (15)

M16 x 1.5

.63 (16)

.87 (22)

.31 (8)

.59 (15)

.75 (19)

M16 x 1.5

.63 (16)

.98 (25)

.31 (8)

.59 (15)

.87 (22)

M20 x 1.5

.79 (20)

1.06 (27)

.35 (9)

.59 (15)

.94 (24)

M20 x 1.5

.79 (20)

1.10 (28)

.35 (9)

.59 (15)

1.06 (27)

M25 x 1.5

.98 (25)

1.22 (31)

.43 (11)

.59 (15)

1.30 (33)

M32 x 1.5

1.26 (32)

1.53 (39)

.43 (11)

.59 (15)

1.65 (42)

M40 x 1.5

1.57 (40)

1.88 (48)

.51 (13)

.71 (18)

2.09 (53)

M50 x 1.5

1.97 (50)

1.93 (49)

.51 (13)

.71 (18)

2.36 (60)

M63 x 1.5

2.48 (63)

1.93 (49)

.55 (14)

.71 (18)

2.56 (65) /
2.68 (68)

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Inches (mm)

Ex-e Multi-Hole &


Romex Glands

(Elongated)

Dimensions in Inches (mm)

Ex-e
Nylon Glands

(Standard)

Thread
Type
& Size

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Nylon
Nylon, Cable Glands for Hazardous Duty Locations, Gray (RAL 7035), Protection Class V0, UL94, NEMA 6, 150 PSIG, IP 68/69K, 10 BAR

Standard
Thread

Buna-N
Seal Insert

Nylon Body
Spline

Ex-e EMI / RFI Nickel


Plated Brass Glands

Dome Nut

Buna-N
(GX)
O-Ring (Included)

Ex-e Conduit &


Fitting Systems

Elongated Thread is recommended where


the Cable Gland has to pass through a thick
wall or the application just needs the Extra
Thread Length.

Ex-e / Ex-d
Accessories

Elongated
Threads

When ordering the Blue version of this product please


substitute UX for GX! (e.g.- CD16DA-UX)

www.sealconex.com

23

Technical
Information

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

II 2G 1D

Nylon - Gray Cable Glands - PG / PG Elongated


UL / CSA / ATEX / IECEx / Inmetro / Ex-e
For Non-Armored Cable

Nylon
Nylon, Cable Glands for Hazardous Duty Locations, Gray (RAL 7035), Protection Class V0, UL94, NEMA 6, 150 PSIG, IP 68/69K, 10 BAR

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Ex-d EXIOS
Cable Glands

ATEX

Part Numbers

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Ex-e Multi-Hole &


Romex Glands

Ex-e
Nylon Glands

-4F to 203F
(-20C to 95C)

Cable Range

-4F to 203F
(-20C to 95C)

(Standard)

(Elongated)

Inches (mm)

CD07AA-GX
CD07AR-GX
CD09AA-GX
CD09AR-GX
CD11AA-GX
CD11AR-GX
CD13AA-GX
CD13AR-GX
CD16AA-GX
CD16AR-GX
CD21AA-GX
CD21AR-GX
CD29AA-GX
CD29AR-GX
CD36AA-GX
CD36AR-GX
CD42AA-GX
CD42AR-GX
CD48AA-GX
CD48AR-GX

CD07CA-GX
CD07CR-GX
CD09CA-GX
CD09CR-GX
CD11CA-GX
CD11CR-GX
CD13CA-GX
CD13CR-GX
CD16CA-GX
CD16CR-GX
CD21CA-GX
CD21CR-GX
CD29CA-GX
CD29CR-GX
CD36CA-GX
CD36CR-GX
CD42CA-GX
CD42CR-GX
CD48CA-GX
CD48CR-GX

.12 - .26 (3 - 6.5)


.08 - .20 (2 - 5)
.16 - .31 (4 - 8)
.12 - .24 (3 - 6)
.20 - .39 (5 - 10)
.12 - .28 (3 - 7)
.26 - .47 (6.5 - 12)
.20 - .35 (5 - 9)
.39 - .55 (10 - 14)
.28 - .47 (7 - 12)
.51 - .71 (13 - 18)
.35 - .63 (9 - 16)
.71 - .98 (18 - 25)
.51 - .79 (13 - 20)
.87 - 1.26 (22 - 32)
.79 - 1.02 (20 - 26)
1.26 - 1.50 (32 - 38)
.98 - 1.22 (25 - 31)
1.46 - 1.73 (37 - 44)
1.14 - 1.38 (29 - 35)

Thread
Type
& Size

Dimensions in Inches (mm)


A

Clearance
Hole

Body
Length

Thread
Length

Thread
Length

Wrench
Flats

Page 59
for Thread
Specs

+ .01
(+.25 mm)

(Dome)

(Standard)

(Elongated)

PG 7

.49 (12.5)

.83 (21)

.31 (8)

.59 (15)

.59 (15)

PG 9

.60 (15.2)

.87 (22)

.31 (8)

.59 (15)

.75 (19)

PG 11

.73 (18.5)

.98 (25)

.31 (8)

.59 (15)

.87 (22)

PG 13

.80 (20.3)

1.06 (27)

.35 (9)

.59 (15)

.94 (24)

PG 16

.89 (22.5)

1.10 (28)

.39 (10)

.59 (15)

1.06 (27)

PG 21

1.12 (28.4)

1.22 (31)

.43 (11)

.59 (15)

1.30 (33)

PG 29

1.47 (37.3)

1.53 (39)

.43 (11)

.59 (15)

1.65 (42)

PG 36

1.85 (47)

1.88 (48)

.51 (13)

.71 (18)

2.09 (53)

PG 42

2.13 (54.1)

1.93 (49)

.51 (13)

.71 (18)

2.36 (60)

PG 48

2.34 (59.4)

1.93 (49)

.55 (14)

.71 (18)

2.56 (65)

Ex-e EMI / RFI Nickel


Plated Brass Glands

Standard
Thread

Buna-N
Seal Insert

Nylon Body
Spline

Buna-N
O-Ring (Included)

Ex-e Conduit &


Fitting Systems

Dome Nut

Elongated Thread is recommended where


the Cable Gland has to pass through a thick
wall or the application just needs the Extra
Thread Length.

Elongated
Threads

Ex-e / Ex-d
Accessories

Technical
Information

(GX)

When ordering the Blue version of this product please


substitute UX for GX! (e.g.- CD16AR-UX)

24

www.sealconex.com

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

II 2G 1D

Anodized Alumium Clamp w/ Nylon Cable Glands


NPT / Metric / PG - ATEX / IECEx / Inmetro / Ex-e

Ex-d EXIOS
Cable Glands

ATEX

For Non-Armored Cable


Part Numbers

Cable Range

-4F to 158F
(-20C to 70C)

Dimensions in Inches (mm)

Thread
Type
& Size

Page 59
for Thread
Specs

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Nylon
Nylon, Cable Glands for Hazardous Duty Locations, Black Anodized Aluminum Clamp
Clamp, V0, UL94, NEMA 6, 150 PSIG, IP 68/69K, 10 BAR

F1/F

Clearance
Hole

Body
Length

Thread
Length

Wrench
Flats

+ .01
(+.25 mm)

(Dome)

(Standard)

Inches (mm)

CD09AA-CP
CD11AA-CP
CD13AA-CP
CD16AA-CP
CD21AA-CP
CD29AA-CP
CD36AA-CP
CD42AA-CP
CD48AA-CP

.16 - .31 (4 - 8)
.24 - .39 (6 - 10)
.24 - .47 (6 - 12)
.39 - .55 (10 - 14)
.51 - .71 (13 - 18)
.71 - .98 (18 - 25)
.87 - 1.26 (22 - 32)
1.26 - 1.50 (32 - 38)
1.46 - 1.73 (37 - 44)

PG 9
PG 11
PG 13
PG 16
PG 21
PG 29
PG 36
PG 42
PG 48

.60 (15.2)
.73 (18.5)
.80 (20.3)
.89 (22.5)
1.12 (28.4)
1.47 (37.3)
1.85 (47)
2.13 (54.1)
2.34 (59.4)

.87 (22)
.98 (25)
1.06 (27)
1.10 (28)
1.22 (31)
1.53 (39)
1.88 (48)
1.93 (49)
1.93 (49)

.59 (15)
.59 (15)
.59 (15)
.39 (10)
.43 (11)
.51 (13)
.51 (13)
.51 (13)
.55 (14)

.75 (19)
.87 (22)
.94 (24)
1.06 (27)
1.30 (33)
1.65 (42)
2.09 (53)
2.36 (60)
2.56 (65)

CD16MA-CP
CD20MA-CP
CD25MA-CP
CD32MA-CP
CD40MA-CP
CD50MA-CP
CD63MA-CP

.16 - .31 (4 - 8)
.24 - .47 (6 - 12)
.51 - .71 (13 - 18)
.71 - .98 (18 - 25)
.87 - - 1.26 (22 - 32)
1.26 - 1.50 (32 - 38)
1.46 - 1.73 (37 - 44)

M16 x 1.5
M20 x 1.5
M25 x 1.5
M32 x1.5
M40 x 1.5
M50 x 1.5
M63 x 1.5

.63 (16)
.79 (20)
.98 (25)
1.26 (32)
1.57 (40)
1.97 (50)
2.48 (63)

1.14 (29)
1.40 (35.5)
1.61 (41)
1.93 (49)
2.28 (58)
2.42 (61.5)
2.44 (62)

.59 (15)
.59 (15)
.43 (11)
.43 (11)
.51 (13)
.51 (13)
.55 (14)

.75 (19)
.94 (24)
1.30 (33)
1.65 (42)
2.09 (53)
2.36 (60)
2.56 (65) / 2.68 (68)

Nylon
Spline

Ex-e Conduit &


Fitting Systems

Anodized
Alumium
Clamp

Ex-e EMI / RFI Nickel


Plated Brass Glands

Nylon body with Anodized


Aluminum Clamp provides extra
pull-out resistance and torque
prevention to the cable.

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Nylon
Body
Only

Ex-e Multi-Hole &


Romex Glands

UL746C
f1

Ex-e
Nylon Glands

(Standard)

Buna-N
O-Ring (Included)

Ex-e / Ex-d
Accessories

(CP)
Buna-N Form
Seal Insert

www.sealconex.com

25

Technical
Information

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Ex-d EXIOS
Cable Glands

II 2G 1D

For Non-Armored Cable


Nylon
Nylon, Cable Glands with Romex Inserts
Inserts, Hazardous Duty Locations, Black/Gray, V0, UL 94, NEMA 6, IP 68
Part Numbers

UL746C
f1

Ex-e EMI / RFI Nickel


Plated Brass Glands

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Ex-e Multi-Hole &


Romex Glands

Ex-e
Nylon Glands

Ex-d Nickel Plated Brass &


Stainless Steel Glands

ATEX

-4F to 203F
(-20C to 95C)

Black

Gray

Thread
Type
& Size

Slot Size

-4F to 203F
(-20C to 95C)

Dimensions in Inches (mm)


A

F1/F

Clearance
Hole

Body
Length

Thread
Length

Wrench
Flats

Page 59
for Thread
Specs

+ .01
(+.25 mm)

(Dome)

(Standard)

1/2-E NPT

.83 (21.1)

1.10 (28)

.51 (13)

1.06 (27)

3/4 NPT
1 NPT

1.05 (26.7)
1.35 (34.3)

1.22 (31)
1.53 (39)

.55 (14)
.75 (19)

1.29 (33)
1.65 (42)

Inches (mm)
HxW

(Standard)

(Standard)

CD16NS-E1
CD16NS-E5
CD21NS-E1
CD29NS-E1

CD16NS-E2
CD16NS-E6
CD21NS-E2
CD29NS-E2

.24 x .55 (6 x 14)


.28 x .47 (7 x 12)
.24 x .55 (6 x 14)
.31 x .87 (8 x 22)

CD29LS-E1

CD29LS-E2

1.26 x .87 (8 x 22)

1-1/4 NPT

1.65 (41.9)

1.53 (39)

.63 (16)

1.65 / 1.81
(42 / 46)

CD36NS-E1
CD36NS-E3
CD36NS-E5
CD36NS-E7

CD36NS-E2
CD36NS-E4
CD36NS-E6
CD36NS-E8

.39 x 1.12 (10 x 28.5)


.22 x 1.14 (5.5 x 29)
.47 x 1.20 (12 x 30.5)
.30 x 1.22 (7.5 x 31)

1-1/2 NPT

1.92 (48.7)

2.09 (53)

.26 (6.5)

.55 (14)

CD22MS-E1
CD22MS-E5
CD25MS-E1
CD25MS-E3
CD32MS-E1
CD40MS-E1
CD40MS-E3
CD40MS-E5
CD40MS-E7
CD50MS-E1

CD22MS-E2
CD22MS-E6
CD25MS-E2
CD25MS-E4
CD32MS-E2
CD40MS-E2
CD40MS-E4
CD40MS-E6
CD40MS-E8
CD50MS-E2

.24 x .55 (6 x 14)


.28 x .47 (7 x 12)
.24 x .55 (6 x 14)
.28 x .55 (7 x 14)
.31 x .87 (8 x 22)
.39 x 1.12 (10 x 28.5)
.20 x 1.14 (5.5 x 29)
.47 x 1.20 (12 x 30.5)
.30 x 1.22 (7.5 x 31)
.45 x 1.31 (11.5 x 33.5)

M20 x 1.5

.79 (20)

1.10 (28)

.35 (9)

1.06 (27)

M25 x 1.5

.98 (25)

1.22 (31)

.43 (11)

1.29 (33)

M32 x 1.5

1.26 (32)

1.53 (39)

.43 (11)

1.65 (42)

M40 x 1.5

1.57 (40)

1.89 (48)

.51 (13)

2.09 (53)

M50 x 1.5

1.97 (50)

1.93 (49)

.51 (13)

2.36 (60)

CD16AS-E1
CD16AS-E5
CD21AS-E1
CD21AS-E3
CD29AS-E1
CD36AS-E1
CD36AS-E3
CD36AS-E5
CD36AS-E7

CD16AS-E2
CD16AS-E6
CD21AS-E2
CD21AS-E4
CD29AS-E2
CD36AS-E2
CD36AS-E4
CD36AS-E6
CD36AS-E8

.24 x .55 (6 x 14)


.28 x .47 (7 x 12))
.24 x .55 (6 x 14)
.28 x .55 (7 x 14)
.31 x .87 (8 x 22)
.39 x 1.12 (10 x 28.5)
.20 x 1.14 (5.5 x 29)
.47 x 1.20 (12 x 30.5)

PG 16

.89 (22.5)

1.10 (28)

.39 (10)

1.06 (27)

PG 21

1.12 (28.4)

1.22 (31)

.43 (11)

1.29 (33)

PG 29

1.47 (37.3)

1.53 (39)

.43 (11)

1.65 (42)

PG 36

1.85 (47)

1.89 (48)

.51 (13)

2.09 (53)

CD42AS-E1

CD42AS-E2

.45 x 1.31 (11.5 x 33.5)

2.13 (54.1)

1.93 (49)

.51 (13)

2.36 (60)

.30 x 1.22 (7.5 x 31)


PG 42

Ex-e Conduit &


Fitting Systems

*Note: UL f1 (746C) rating applies to Black Nylon Fittings only.

ROMEX is a federally registered trademark of Southwire Company.


Black Nylon
Body Only

UL746C
f1

Cable Glands with Inserts for Flat Cables


These form seals are also available with Cable Glands made of other
materials. (Nickel Plated Brass, Stainless Steel, etc.)

Ex-e / Ex-d
Accessories

Technical
Information

Romex - Nylon - Black / Gray Cable Glands


NPT / Metric / PG - UL / ATEX / Inmetro / Ex-e

* Additional UL Information
Our FLAKA (for Romex style cable) HSK-K-Ex PG 16 & 1/2-Enlarged are UL listed.
UL file # E168975.
To meet UL, only Romex style cable (flat top and bottom) can be used with this style
Cable Glands (No Zip Cable, No Ribbon cable, etc.)

26

www.sealconex.com

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Thermo Plastic
Elastomer Form
Seal Insert

Romex - Nickel Plated Brass Cable Glands


NPT / Metric / PG - UL / ATEX / IECEx / Inmetro / Ex-e

Ex-d EXIOS
Cable Glands

ATEX

II 2G 1D

For Non-Armored Cable


Part Numbers

Slot Size

-4F to 203F
(-20C to 95C)

Thread
Type
& Size

(Standard)

Inches (mm)
HxW

Clearance
Hole

Body
Length

Thread
Length

Wrench
Flats

Page 59
for Thread
Specs

+ .01
(+.25 mm)

.24 x .55 (6 x 14)


.28 x .55 (7 x 14)
.31 x .87 (8 x 22)

(Dome)

(Standard)

3/4 NPT

1.05 (26.7)

.98 (25)

.51 (13)

1.18 (30)

1 NPT

1.35 (34.3)

1.14 (29)

.75 (19)

1.57 (40)

CD22MS-EB1
CD22MS-EB2
CD25MS-EB1
CD25MS-EB2
CD32MS-EB1
CD40MS-EB1
CD40MS-EB2
CD40MS-EB3
CD40MS-EB4
CD50MS-EB1
CD63MS-EB1

.24 x .55 (6 x 14)


.28 x .47 (7 x 12)
.24 x .55 (6 x 14)
.28 x .55 (7 x 14)
.31 x .87 (8 x 22)
.39 x 1.12 (10 x 28.5)
.20 x 1.14 (5.5 x 29)
.47 x 1.20 (12 x 30.5)
.29 x 1.22 (7.5 x 31)
.45 x 1.31 (11.5 x 33.5)
.47 x 1.50 (12 x 38)

M20 x 1.5

.79 (20)

.94 (24)

.24 (6)

.94 (24)

M25 x 1.5

.98 (25)

1.02 (26)

.28 (7)

1.18 (30)

M32 x 1.5

1.26 (32)

1.22 (31)

.31 (8)

1.57 (40)

M40 x 1.5

1.57 (40)

1.46 (37)

.31 (8)

1.97 (50)

M50 x 1.5
M63 x 1.5

1.97 (50)
2.48 (63)

1.46 (37)
1.49 (38)

.35 (9)
.39 (10)

2.24 (57)
2.52 (64) / 2.68 (68)

CD16AS-EB1
CD16AS-EB2
CD21AS-EB1
CD21AS-EB2
CD29AS-EB1
CD36AS-EB1
CD36AS-EB2
CD36AS-EB3
CD36AS-EB4
CD42AS-EB1
CD48AS-EB2

.24 x .55 (6 x 14)


.28 x .47 (7 x 12)
.24 x .55 (6 x 14)
.28 x .55 (7 x 14)
.31 x .87 (8 x 22)
.39 x 1.12 (10 x 28.5)
.20 x 1.14 (5.5 x 29)
.47 x 1.18(12 x 30)
.29 x 1.22 (7.5 x 31)
.45 x 1.31 (11.5 x 33.5)
.47 x 1.50 (12 x 38)

PG 16

.89 (22.5)

.91 (23)

.26 (6.5)

.94 (24)

PG 21

1.12 (28.4)

.94 (24)

.28 (7)

1.18 (30)

PG 29

1.47 (37.3)

1.14 (29)

.31 (8)

1.57 (40)

PG 36

1.85 (47)

1.37 (35)

.31 (8)

1.97 (50)

PG 42
PG 48

2.13 (54.1)
2.34 (59.4)

1.46 (37)
1.49 (38)

.35 (9)
.39 (10)

2.24 (57)
2.52 (64)

Ex-e EMI / RFI Nickel


Plated Brass Glands

F1/F

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Ex-e Multi-Hole &


Romex Glands

Ex-e
Nylon Glands

CD21NS-EB1
CD21NS-EB2
CD29NS-EB1

Dimensions in Inches (mm)


A

Nickel Plated Brass

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Nickel Plated Brass


Brass, Cable Glands with Romex Inserts
Inserts, Hazardous Duty Locations, V0, UL94, NEMA 6, IP 68

ROMEX is a federally registered trademark of Southwire Company.

Cable Glands with Inserts for Flat Cables


These form seals are also available with Cable Glands made of other materials. (Nickel Plated Brass, Stainless Steel, etc.)

Ex-e Conduit &


Fitting Systems

Elastomer Form
Seal Insert

Ex-e / Ex-d
Accessories

Thermo Plastic
Elastomer Form
Seal Insert

* Additional UL Information

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

www.sealconex.com

27

Technical
Information

Our FLAKA (for Romex style cable) HSK-K-Ex PG16 are UL listed
(UL file # E168975)
To meet UL, only Romex style cable (flat top and bottom) can be used
with this style Cable Gland (No Zip Cable, No Ribbon cable, etc.)

Ex-d EXIOS
Cable Glands

II 2G 1D

Multi-Hole - Nylon / Nickel Plated Brass Cable Glands


NPT - UR / CSA / ATEX / IECEx / Inmetro / Ex-e

Nylon & Nickel Plated Brass


Brass, Cable Glands with Multi-Hole Inserts
Inserts, Hazardous Duty Locations, V0, UL94, NEMA 6, IP 68
Part Numbers

UL746C
f1

-4F to 203F
(-20C to 95C)

-4F to 203F
(-20C to 95C)

-4F to 203F
(-20C to 95C)

Black

Gray

Nickel Plated Brass

**

Thread
Type
& Size

Ex-e Multi-Hole &


Romex Glands

Ex-e Nickel Plated Brass &


Stainless Steel Glands

CD09N1-BX
CD09N2-BX
CD09N3-BX
CD09N4-BX
CD09N5-BX
CD09N6-BX
CD09N7-BX
CD09N8-BX
CD09N9-BX
CD09NP-BX

CD09N1-GX
CD09N2-GX
CD09N3-GX
CD09N4-GX
CD09N5-GX
CD09N6-GX
CD09N7-GX
CD09N8-GX
CD09N9-GX
CD09NP-GX

CD09N1-MX
CD09N2-MX
CD09N3-MX
CD09N4-MX
CD09N5-MX
CD09N6-MX
CD09N7-MX
CD09N8-MX
CD09N9-MX
CD09NP-MX

CD13N1-BX
CD13N2-BX
CD13N3-BX
CD13N4-BX
CD13N5-BX
CD13N6-BX
CD13N7-BX
CD13N8-BX
CD13N9-BX
CD13NP-BX

CD13N1-GX
CD13N2-GX
CD13N3-GX
CD13N4-GX
CD13N5-GX
CD13N6-GX
CD13N7-GX
CD13N8-GX
CD13N9-GX
CD13NP-GX

CD13N1-MX
CD13N2-MX
CD13N3-MX
CD13N4-MX
CD13N5-MX
CD13N6-MX
CD13N7-MX
CD13N8-MX
CD13N9-MX
CD13NP-MX

CD16N0-BX
CD16N1-BX
CD16N2-BX
CD16N3-BX
CD16N4-BX
CD16N5-BX
CD16N6-BX
CD16N7-BX
CD16N8-BX
CD16NP-BX

CD16N0-GX
CD16N1-GX
CD16N2-GX
CD16N3-GX
CD16N4-GX
CD16N5-GX
CD16N6-GX
CD16N7-GX
CD16N8-GX
CD16NP-GX

CD16N0-MX
CD16N1-MX
CD16N2-MX
CD16N3-MX
CD16N4-MX
CD16N5-MX
CD16N6-MX
CD16N7-MX
CD16N8-MX
CD16NP-MX

No.
of
Holes

3/8 NPT

1/2 NPT

1/2-E NPT

Diameter
of Holes

Part Numbers of
Inserts only

mm

Inches

4
2
5
2
10
6
3
4
4

1.4
3.0
1.6
1.7
1.4
1.4
1.7
1.7
2.3
Solid Insert

.06
.12
.06
.07
.06
.06
.07
.07
.09

1.089.0900.19
1.089.0901.19
1.089.0902.19
1.089.0903.19
1.089.0904.19
1.089.0905.19
1.089.0906.19
1.089.0907.19
1.089.0908.19
1.089.0999.19

3
6
3
2
3
2
2
2
2

2.0
3.0
4.0
5.0
3.0
5.2
3.8
4.2
2.5
Solid Insert

.08
.12
.16
.20
.12
.20
.15
.17
.10

1.089.1300.19
1.089.1301.19
1.089.1302.19
1.089.1303.19
1.089.1304.19
1.089.1305.19
1.089.1306.19
1.089.1307.19
1.089.1308.19
1.089.1399.19

6
3
3
4
5
6
2
3
6

3.8
3.0
4.0
4.0
4.0
4.0
6.0
5.6
3.0
Solid Insert

.15
.12
.16
.16
.16
.16
.24
.22
.12

1.089.1609.19
1.089.1600.19
1.089.1601.19
1.089.1602.19
1.089.1603.19
1.089.1604.19
1.089.1605.19
1.089.1606.19
1.089.1607.19
1.089.1699.19

* Note: IECEx approval appy only to Nickel Plated Brass Multi-Hole


**Note: UL f1 (746C) rating applies to Black Nylon Fittings only.

For Specifications and Dimensions for Black & Gray Nylon


(page 22) or Nickel Plated Brass (page 35) where the
appropriate Fittings are listed.

Ex-e / Ex-d
Accessories

Technical
Information

Dimensions in Inches (mm)

Page 59
for Thread
Specs

Ex-e Conduit &


Fitting Systems

Ex-e EMI / RFI Nickel


Plated Brass Glands

For Non-Armored Cable

Ex-e
Nylon Glands

Ex-d Nickel Plated Brass &


Stainless Steel Glands

ATEX

Thermo Plastic
Elastomer Form
Seal Insert

Buna-N
O-Ring (Included)

28

www.sealconex.com

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

***

Multi-Hole - Nylon / Nickel Plated Brass Cable Glands


NPT - UR / CSA / ATEX / IECEx / Inmetro / Ex-e

Ex-d EXIOS
Cable Glands

ATEX

II 2G 1D

For Non-Armored Cable


Part Numbers
-4F to 203F
(-20C to 95C)
UL746C
f1

** Black

-4F to 203F
(-20C to 95C)

-4F to 203F
(-20C to 95C)

Gray

Nickel Plated Brass

Thread
Type
& Size

Dimensions in Inches (mm)


No.
of Holes

Page 59
for Thread
Specs

CD29N1-BX
CD29N2-BX
CD29N3-BX
CD29NP-BX

CD29N1-GX
CD29N2-GX
CD29N3-GX
CD29NP-GX

CD29N1-MX
CD29N2-MX
CD29N3-MX
CD29NP-MX

CD29L1-BX
CD29L2-BX
CD29L3-BX
CD29LP-BX

CD29L1-GX
CD29L2-GX
CD29L3-GX
CD29LP-GX

CD36N1-BX
CD36N2-BX
CD36N3-BX
CD36N4-BX
CD36NP-BX

CD36N1-GX
CD36N2-GX
CD36N3-GX
CD36N4-GX
CD36NP-GX

3/4 NPT

1 NPT

1-1/4 NPT

1-1/2 NPT

mm

Inches

4
3
2
4
1
4
3
4/1
2

6.0
7.0
8.0
5.0
8.0
5.2
5.2
5.2/3.7
7.4
Solid Insert

.24
.28
.31
.20
.31
.20
.20
.20/.15
.29

1.089.2100.19
1.089.2101.19
1.089.2102.19
1.089.2103.19
1.089.2104.19
1.089.2105.19
1.089.2106.19
1.089.2107.19
1.089.2108.19
1.089.2199.19

6
4
4

6.5
9.0
9.5
Solid Insert

.26
.35
.37

1.089.2900.19
1.089.2901.19
1.089.2902.19
1.089.2999.19

6
4
4

6.5
9.0
9.5
Solid Insert

.26
.35
.37

1.089.2900.19
1.089.2901.19
1.089.2902.19
1.089.2999.19

5
7
6
2

9.0
9.0
8.0
15.0
Solid Insert

.35
.35
.31
.59

1.089.3600.19
1.089.3601.19
1.089.3602.19
1.089.3603.19
1.089.3699.19

Ex-e Nickel Plated Brass &


Stainless Steel Glands

CD21N1-MX
CD21N2-MX
CD21N3-MX
CD21N4-MX
CD21N5-MX
CD21N6-MX
CD21N7-MX
CD21N8-MX
CD21N9-MX
CD21NP-MX

Part Numbers
of Inserts only

Ex-e Multi-Hole &


Romex Glands

CD21N1-GX
CD21N2-GX
CD21N3-GX
CD21N4-GX
CD21N5-GX
CD21N6-GX
CD21N7-GX
CD21N8-GX
CD21N9-GX
CD21NP-GX

Diameter
of Holes

Ex-e
Nylon Glands

CD21N1-BX
CD21N2-BX
CD21N3-BX
CD21N4-BX
CD21N5-BX
CD21N6-BX
CD21N7-BX
CD21N8-BX
CD21N9-BX
CD21NP-BX

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Nylon & Nickel Plated Brass


Brass, Cable Glands with Multi-Hole Inserts
Inserts, Hazardous Duty Locations, V0, UL94, NEMA 6, IP 68

***Note: InMetro only applies to all Nylon Cable Glands.

Ex-e EMI / RFI Nickel


Plated Brass Glands

* Note: IECEx approval appy only to Nickel Plated Brass Multi-Hole


**Note: UL f1 (746C) rating applies to Black Nylon Fittings only.

Ex-e Conduit &


Fitting Systems

For Specifications and Dimensions for Black & Gray


Nylon (page 22) or Nickel Plated Brass (page 35)
where the appropriate Fittings are listed.

Thermo Plastic
Elastomer Insert

Ex-e / Ex-d
Accessories

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

www.sealconex.com

29

Technical
Information

Buna-N
O-Ring (Included)

Ex-d EXIOS
Cable Glands

Multi-Hole - Nylon / Nickel Plated Brass Cable Glands


Metric - UR / CSA / ATEX / IECEx / Inmetro / Ex-e

***

For Non-Armored Cable


Nylon & Nickel Plated Brass
Brass, Cable Glands with Multi-Hole Inserts
Inserts, Hazardous Duty Locations, V0, UL94, NEMA 6, IP 68
Part Numbers

UL746C
f1

-4F to 203F
(-20C to 95C)

-4F to 203F
(-20C to 95C)

-4F to 203F
(-20C to 95C)

Black

Gray

Nickel Plated Brass

**

Thread
Type
& Size

Dimensions in Inches (mm)

Ex-e Multi-Hole &


Romex Glands

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Ex-e EMI / RFI Nickel


Plated Brass Glands

Ex-e Conduit &


Fitting Systems

CD12MP-BX

CD12MP-GX

CD12MP-MX

CD16M1-BX
CD16M2-BX
CD16M3-BX
CD16M4-BX
CD16M5-BX
CD16M6-BX
CD16M7-BX
CD16M8-BX
CD16M9-BX
CD16MP-BX

CD16M1-GX
CD16M2-GX
CD16M3-GX
CD16M4-GX
CD16M5-GX
CD16M6-GX
CD16M7-GX
CD16M8-GX
CD16M9-GX
CD16MP-GX

CD16M1-MX
CD16M2-MX
CD16M3-MX
CD16M4-MX
CD16M5-MX
CD16M6-MX
CD16M7-MX
CD16M8-MX
CD16M9-MX
CD16MP-MX

CD17M1-BX
CD17M2-BX
CD17M3-BX
CD17M4-BX
CD17M5-BX
CD17MP-BX

CD17M1-GX
CD17M2-GX
CD17M3-GX
CD17M4-GX
CD17M5-GX
CD17MP-GX

CD17M1-MX
CD17M2-MX
CD17M3-MX
CD17M4-MX
CD17M5-MX
CD17MP-MX

CD20M1-BX
CD20M2-BX
CD20M3-BX
CD20M4-BX
CD20M5-BX
CD20M6-BX
CD20M7-BX
CD20M8-BX
CD20M9-BX
CD20MP-BX

CD20M1-GX
CD20M2-GX
CD20M3-GX
CD20M4-GX
CD20M5-GX
CD20M6-GX
CD20M7-GX
CD20M8-GX
CD20M9-GX
CD20MP-GX

CD20M1-MX
CD20M2-MX
CD20M3-MX
CD20M4-MX
CD20M5-MX
CD20M6-MX
CD20M7-MX
CD20M8-MX
CD20M9-MX
CD20MP-MX

CD22M0-BX
CD22M1-BX
CD22M2-BX
CD22M3-BX
CD22M4-BX
CD22M5-BX
CD22M6-BX
CD22M7-BX
CD22M8-BX
CD22MP-BX

CD22M0-GX
CD22M1-GX
CD22M2-GX
CD22M3-GX
CD22M4-GX
CD22M5-GX
CD22M6-GX
CD22M7-GX
CD22M8-GX
CD22MP-GX

CD22M0-MX
CD22M1-MX
CD22M2-MX
CD22M3-MX
CD22M4-MX
CD22M5-MX
CD22M6-MX
CD22M7-MX
CD22M8-MX
CD22MP-MX

mm

M12 x 1.5

M16 x 1.5

M16 x 1.5
(Enlarged)

M20 x 1.5

M20 x 1.5
(Enlarged)

Diameter
of Holes

No. of Holes

Page 59
for Thread
Specs

www.sealconex.com

Inches

Solid Insert

1.089.0799.19

4
2
5
2
10
6
3
4
4

1.4
3.0
1.6
1.7
1.4
1.4
1.7
1.7
2.3
Solid Insert

.06
.12
.06
.07
.06
.06
.07
.07
.09

1.089.0900.19
1.089.0901.19
1.089.0902.19
1.089.0903.19
1.089.0904.19
1.089.0905.19
1.089.0906.19
1.089.0907.19
1.089.0908.19
1.089.0999.19

2
3
2
3
4

3.0
3.0
4.0
1.5
2.8
Solid Insert

.12
.12
.16
.06
.11

1.089.1100.19
1.089.1101.19
1.089.1102.19
1.089.1103.19
1.089.1104.19
1.089.1199.19

3
6
3
2
3
2
2
2
2

2.0
3.0
4.0
5.0
3.0
5.2
3.8
4.2
2.5
Solid Insert

.08
.12
.16
.20
.12
.20
.15
.17
.10

1.089.1300.19
1.089.1301.19
1.089.1302.19
1.089.1303.19
1.089.1304.19
1.089.1305.19
1.089.1306.19
1.089.1307.19
1.089.1308.19
1.089.1399.19

6
3
3
4
5
6
2
3
6

3.8
3.0
4.0
4.0
4.0
4.0
6.0
5.6
3.0
Solid Insert

.15
.12
.16
.16
.16
.16
.24
.22
.12

1.089.1609.19
1.089.1600.19
1.089.1601.19
1.089.1602.19
1.089.1603.19
1.089.1604.19
1.089.1605.19
1.089.1606.19
1.089.1607.19
1.089.1699.19

For Specifications and Dimensions for Black (page 20) & Gray
Nylon (page 22) or Nickel Plated Brass (page 35) where the
appropriate Fittings are listed.

30

Part Numbers
of Inserts only

***Note: InMetro only applies to all Nylon Cable Glands.

* Note: IECEx approval appy only to Nickel Plated Brass Multi-Hole


**Note: UL F1 rating applies to Black Nylon Fittings only.

Ex-e / Ex-d
Accessories

Technical
Information

II 2G 1D

Ex-e
Nylon Glands

Ex-d Nickel Plated Brass &


Stainless Steel Glands

ATEX

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

***

Multi-Hole - Nylon / Nickel Plated Brass Cable Glands


Metric - UR / CSA / ATEX / IECEx / Inmetro / Ex-e

Ex-d EXIOS
Cable Glands

ATEX

II 2G 1D

For Non-Armored Cable


Part Numbers
-4F to 203F
(-20C to 95C)
UL746C
f1

** Black

-4F to 203F
(-20C to 95C)

-4F to 203F
(-20C to 95C)

Gray

Nickel Plated Brass

Thread
Type
& Size

Dimensions in Inches (mm)

CD32M1-MX
CD32M2-MX
CD32M3-MX
CD32MP-MX

CD40M1-BX
CD40M2-BX
CD40M3-BX
CD40M4-BX
CD40MP-BX

CD40M1-GX
CD40M2-GX
CD40M3-GX
CD40M4-GX
CD40MP-GX

CD40M1-MX
CD40M2-MX
CD40M3-MX
CD40M4-MX
CD40MP-MX

M40 x 1.5

CD50MP-BX

CD50MP-GX

CD50MP-MX

M50 x 1.5

CD63M1-BX
CD63M2-BX
CD63M3-BX
CD63MP-BX

CD63M1-GX
CD63M2-GX
CD63M3-GX
CD63MP-GX

CD63M1-MX
CD63M2-MX
CD63M3-MX
CD63MP-MX

M32 x 1.5

M63 x 1.5

* Note: IECEx approval appy only to Nickel Plated Brass Multi-Hole


**Note: UL F1 rating applies to Black Nylon Fittings only.

4
3
2
4
1
4
3
4/1
2

6.0
7.0
8.0
5.0
8.0
5.2
5.2
5.2/3.7
7.4
Solid Insert

.24
.28
.31
.20
.31
.20
.20
.20/.15
.29

1.089.2100.19
1.089.2101.19
1.089.2102.19
1.089.2103.19
1.089.2104.19
1.089.2105.19
1.089.2106.19
1.089.2107.19
1.089.2108.19
1.089.2199.19

6
4
4

6.5
9.0
9.5
Solid Insert

.26
.35
.37

1.089.2900.19
1.089.2901.19
1.089.2902.19
1.089.2999.19

5
7
6
2

9.0
9.0
8.0
15.0
Solid Insert

.35
.35
.31
.59

1.089.3600.19
1.089.3601.19
1.089.3602.19
1.089.3603.19
1.089.3699.19

Solid Insert
8
6
3

10.0
12.0
18.0
Solid Insert

1.089.4299.19
.39
.47
.71

1.089.4800.19
1.089.4801.19
1.089.4802.19
1.089.4899.19

Ex-e EMI / RFI Nickel


Plated Brass Glands

CD32M1-GX
CD32M2-GX
CD32M3-GX
CD32MP-GX

Inches

Ex-e Nickel Plated Brass &


Stainless Steel Glands

CD32M1-BX
CD32M2-BX
CD32M3-BX
CD32MP-BX

M25 x 1.5

mm

Ex-e Multi-Hole &


Romex Glands

CD25M1-MX
CD25M2-MX
CD25M3-MX
CD25M4-MX
CD25M5-MX
CD25M6-MX
CD25M7-MX
CD25M8-MX
CD25M9-MX
CD25MP-MX

Part Numbers of
Inserts only

Ex-e
Nylon Glands

CD25M1-GX
CD25M2-GX
CD25M3-GX
CD25M4-GX
CD25M5-GX
CD25M6-GX
CD25M7-GX
CD25M8-GX
CD25M9-GX
CD25MP-GX

Diameter
of Holes

No. of Holes

Page 59
for Thread
Specs

CD25M1-BX
CD25M2-BX
CD25M3-BX
CD25M4-BX
CD25M5-BX
CD25M6-BX
CD25M7-BX
CD25M8-BX
CD25M9-BX
CD25MP-BX

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Nylon & Nickel Plated Brass


Brass, Cable Glands with Multi-Hole Inserts
Inserts, Hazardous Duty Locations, V0, UL94, NEMA 6, IP 68

***Note: InMetro only applies to all Nylon Cable Glands.

For Specifications and Dimensions for Black (page 20) & Gray
Nylon (page 22) or Nickel Plated Brass (page 35) where the
appropriate Fittings are listed.

Ex-e Conduit &


Fitting Systems

Optional Locking Nuts &


Other Accessories on
page 46 - 54

Ex-e / Ex-d
Accessories

Thermo PlasticElastomer
Insert

www.sealconex.com

31

Technical
Information

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

***

Multi-Hole - Nylon / Nickel Plated Brass Cable Glands


PG - UR / CSA / ATEX / IECEx / Inmetro / Ex-e
For Non-Armored Cable

Nylon & Nickel Plated Brass


Brass, Cable Glands with Multi-Hole Inserts
Inserts, Hazardous Duty Locations, V0, UL94, NEMA 6, IP 68
Part Numbers
-4F to 203F
(-20C to 95C)

Ex-e Conduit &


Fitting Systems

Ex-e EMI / RFI Nickel


Plated Brass Glands

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Ex-e Multi-Hole &


Romex Glands

Ex-e
Nylon Glands

UL746C
f1

-4F to 203F
(-20C to 95C)

-4F to 203F
(-20C to 95C)

Gray

Nickel Plated Brass

** Black

CD07AP-BX

CD07AP-GX

CD07AP-MX

CD09A1-BX
CD09A2-BX
CD09A3-BX
CD09A4-BX
CD09A5-BX
CD09A6-BX
CD09A7-BX
CD09A8-BX
CD09A9-BX
CD09AP-BX

CD09A1-GX
CD09A2-GX
CD09A3-GX
CD09A4-GX
CD09A5-GX
CD09A6-GX
CD09A7-GX
CD09A8-GX
CD09A9-GX
CD09AP-GX

CD09A1-MX
CD09A2-MX
CD09A3-MX
CD09A4-MX
CD09A5-MX
CD09A6-MX
CD09A7-MX
CD09A8-MX
CD09A9-MX
CD09AP-MX

CD11A1-BX
CD11A2-BX
CD11A3-BX
CD11A4-BX
CD11A5-BX
CD11AP-BX

CD11A1-GX
CD11A2-GX
CD11A3-GX
CD11A4-GX
CD11A5-GX
CD11AP-GX

CD11A1-MX
CD11A2-MX
CD11A3-MX
CD11A4-MX
CD11A5-MX
CD11AP-MX

CD13A1-BX
CD13A2-BX
CD13A3-BX
CD13A4-BX
CD13A5-BX
CD13A6-BX
CD13A7-BX
CD13A8-BX
CD13A9-BX
CD13AP-BX

CD13A1-GX
CD13A2-GX
CD13A3-GX
CD13A4-GX
CD13A5-GX
CD13A6-GX
CD13A7-GX
CD13A8-GX
CD13A9-GX
CD13AP-GX

CD13A1-MX
CD13A2-MX
CD13A3-MX
CD13A4-MX
CD13A5-MX
CD13A6-MX
CD13A7-MX
CD13A8-MX
CD13A9-MX
CD13AP-MX

CD16A0-BX
CD16A1-BX
CD16A2-BX
CD16A3-BX
CD16A4-BX
CD16A5-BX
CD16A6-BX
CD16A7-BX
CD16A8-BX
CD16AP-BX

CD16A0-GX
CD16A1-GX
CD16A2-GX
CD16A3-GX
CD16A4-GX
CD16A5-GX
CD16A6-GX
CD16A7-GX
CD16A8-GX
CD16AP-GX

CD16A0-MX
CD16A1-MX
CD16A2-MX
CD16A3-MX
CD16A4-MX
CD16A5-MX
CD16A6-MX
CD16A7-MX
CD16A8-MX
CD16AP-MX

Thread
Type
& Size

Dimensions in Inches (mm)


No.
of
Holes

Diameter
of Holes

Page 59
for Thread
Specs

mm

PG 7

Solid Insert

PG 9

PG 11

PG 13 / 13.5

PG 16

4
2
5
2
10
6
3
4
4
2
3
2
3
4

www.sealconex.com

Inches

1.089.0799.19

1.4
.06
1.089.0900.19
3.0
.12
1.089.0901.19
1.6
.06
1.089.0902.19
1.7
.07
1.089.0903.19
1.4
.06
1.089.0904.19
1.4
.06
1.089.0905.19
1.7
.07
1.089.0906.19
1.7
.07
1.089.0907.19
For specifications
and
2.3
.09
1.089.0908.19
4
Solid Insert dimensions see page
1.089.0999.19
where the appropriate
Fittings
3.0
.12are listed. 1.089.1100.19
3.0
.12
1.089.1101.19
4.0
.16
1.089.1102.19
1.5
.06
1.089.1103.19
2.8
.11
1.089.1104.19
Solid Insert
1.089.1199.19

3
6
3
2
3
2
2
2
2

2.0
3.0
4.0
5.0
3.0
5.2
3.8
4.2
2.5
Solid Insert

.08
.12
.16
.20
.12
.20
.15
.17
.10

1.089.1300.19
1.089.1301.19
1.089.1302.19
1.089.1303.19
1.089.1304.19
1.089.1305.19
1.089.1306.19
1.089.1307.19
1.089.1308.19
1.089.1399.19

6
3
3
4
5
6
2
3
6

3.8
3.0
4.0
4.0
4.0
4.0
6.0
5.6
3.0
Solid Insert

.15
.12
.16
.16
.16
.16
.24
.22
.12

1.089.1609.19
1.089.1600.19
1.089.1601.19
1.089.1602.19
1.089.1603.19
1.089.1604.19
1.089.1605.19
1.089.1606.19
1.089.1607.19
1.089.1699.19

For Specifications and Dimensions for Black (page 21) & Gray
Nylon (page 22) or Nickel Plated Brass (page 36) where the
appropriate Fittings are listed.

32

Part Numbers of
Inserts only

***Note: InMetro only applies to all Nylon Cable Glands.

* Note: IECEx approval appy only to Nickel Plated Brass Multi-Hole


**Note: UL F1 rating applies to Black Nylon Fittings only.

Ex-e / Ex-d
Accessories

Technical
Information

II 2G 1D

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Ex-d EXIOS
Cable Glands

ATEX

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

***

Multi-Hole - Nylon / Nickel Plated Brass Cable Glands


PG - UR / CSA / ATEX / IECEx / Inmetro / Ex-e

Ex-d EXIOS
Cable Glands

ATEX

II 2G 1D

For Non-Armored Cable


Part Numbers
-4F to 203F
(-20C to 95C)
UL746C
f1

** Black

Thread
Type
& Size

-4F to 203F
(-20C to 95C)

-4F to 203F
(-20C to 95C)

Gray

Nickel Plated Brass

Dimensions in Inches (mm)


No.
of
Holes

Diameter
of Holes

Page 59
for Thread
Specs

CD29A1-GX
CD29A2-GX
CD29A3-GX
CD29AP-GX

CD29A1-MX
CD29A2-MX
CD29A3-MX
CD29AP-MX

CD36A1-BX
CD36A2-BX
CD36A3-BX
CD36A4-BX
CD36AP-BX

CD36A1-GX
CD36A2-GX
CD36A3-GX
CD36A4-GX
CD36AP-GX

CD36A1-MX
CD36A2-MX
CD36A3-MX
CD36A4-MX
CD36AP-MX

PG 36

CD42AP-BX

CD42AP-GX

CD42AP-MX

PG 42

CD48A1-BX
CD48A2-BX
CD48A3-BX
CD48AP-BX

CD48A1-GX
CD48A2-GX
CD48A3-GX
CD48AP-GX

CD48A1-MX
CD48A2-MX
CD48A3-MX
CD48AP-MX

PG 29

PG 48

Inches

6.0
7.0
8.0
5.0
8.0
5.2
5.2
5.2/3.7
7.4
Solid Insert

.24
.28
.31
.20
.31
.20
.20
.20/.15
.29

1.089.2100.19
1.089.2101.19
1.089.2102.19
1.089.2103.19
1.089.2104.19
1.089.2105.19
1.089.2106.19
1.089.2107.19
1.089.2108.19
1.089.2199.19

6
4
4

6.5
9.0
9.5
Solid Insert

.26
.35
.37

1.089.2900.19
1.089.2901.19
1.089.2902.19
1.089.2999.19

5
7
6
2

9.0
9.0
8.0
15.0
Solid Insert

.35
.35
.31
.59

1.089.3600.19
1.089.3601.19
1.089.3602.19
1.089.3603.19
1.089.3699.19

Solid Insert
8
6
3

10.0
12.0
18.0
Solid Insert

1.089.4299.19
.39
.47
.71

1.089.4800.19
1.089.4801.19
1.089.4802.19
1.089.4899.19

***Note: InMetro only applies to all Nylon Cable Glands.

* Note: IECEx approval appy only to Nickel Plated Brass Multi-Hole


**Note: UL F1 rating applies to Black Nylon Fittings only.

Thermo
Plastic
Elastomer
Insert

Ex-e EMI / RFI Nickel


Plated Brass Glands

CD29A1-BX
CD29A2-BX
CD29A3-BX
CD29AP-BX

PG 21

mm

4
3
2
4
1
4
3
4/1
2

Ex-e Nickel Plated Brass &


Stainless Steel Glands

CD21A1-MX
CD21A2-MX
CD21A3-MX
CD21A4-MX
CD21A5-MX
CD21A6-MX
CD21A7-MX
CD21A8-MX
CD21A9-MX
CD21AP-MX

Ex-e Multi-Hole &


Romex Glands

CD21A1-GX
CD21A2-GX
CD21A3-GX
CD21A4-GX
CD21A5-GX
CD21A6-GX
CD21A7-GX
CD21A8-GX
CD21A9-GX
CD21AP-GX

Part Numbers of
Inserts only

Ex-e
Nylon Glands

CD21A1-BX
CD21A2-BX
CD21A3-BX
CD21A4-BX
CD21A5-BX
CD21A6-BX
CD21A7-BX
CD21A8-BX
CD21A9-BX
CD21AP-BX

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Nylon & Nickel Plated Brass


Brass, Cable Glands with Multi-Hole Inserts
Inserts, Hazardous Duty Locations, V0, UL94, NEMA 6, IP 68

Ex-e Conduit &


Fitting Systems

Ex-e / Ex-d
Accessories

Optional Locking Nuts &


Other Accessories starting
on page 46 - 54.
For Specifications and Dimensions for Black (page 21) & Gray
Nylon (page 22) or Nickel Plated Brass (page 36) where the
appropriate Fittings are listed.

www.sealconex.com

33

Technical
Information

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

For Non-Armored Cable


Technical Description








Ex-e
Nylon Glands

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Ex-d EXIOS
Cable Glands

Nickel Plated Brass & Stainless Steel Cable Glands


Features & Benefits - Ex-e
E103997
104031
0 UE11

Ex-e Cable Glands for non-armored cable - Cost Saving Option!


Approvals & Certifications - ATEX/IECEx, UL/UR, CE, CSA, Gost and German Lloyd!
Ref. Standards
NEMA 4x & 6 (IP 67 & 68) - Liquid Tight - Submersible to 300 ft!
EN 60079-0
IP 69K rated - Ideal in splash or hose down applications!
EN 60079-7
Patented form seal allows 150 PSIG (10 BAR) rating - Highest in Industry!
V0 flame rating according to UL 94 Halogen & Phosphorous Free non toxic!
RoHS & Deca BDE - Environmentally Compliant to the newest standards!
Large selection in Nickel Plated Brass and Stainless Steel - Cable Range from .08 (2 mm) to 1.73 (44 mm)
Non-Corrosive - Resistant to salt water, weak acids, weak alkalis, alcohol, esters, ketones, ether, gasoline,
mineral, animal & vegetable oil.

Ex-e Multi-Hole &


Romex Glands

Your One Stop Solution For All Cable & Wire Accessories!

Unique Product

Ex-e Nickel Plated Brass &


Stainless Steel Glands

The patented recess form seal guarantees


NEMA 4x & 6 (IP 68 / IP 69K) at 150 PSIG (10 BAR).

Pull-out Resistance & Cable Protection


Overlapping clamping splines apply a concentric
force, preventing the form seal from being pulled out
of the gland. This ensures pull-out protection without
damage to the cable.

Ex-e EMI / RFI Nickel


Plated Brass Glands

Liquid Tight

Ex-e Conduit &


Fitting Systems

Machined O-Ring Groove: All of our Ex Cable Glands


come with an O-Ring, resulting in a Liquid Tight Seal
between cable gland and installation.

Time Saving Installation


Simply push the cable through Cable Glands - Tighten Dome Nut - Done!
No disassembly of the cable glands required!

Ex-e / Ex-d
Accessories

Technical
Information

UL/UR
CSA
CAGE

II 2G 1D

ATEX
34

www.sealconex.com

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Nickel Plated Brass Cable Glands - Low Temperature


NPT / Metric - UL / UR / CSA / ATEX / IECEx / Ex-e

II 2G 1D

Ex-d EXIOS
Cable Glands

ATEX

For Non-Armored Cable


Part Numbers
-4F to 203F
(-20C to 95C)

Cable Range

-76F to 203F
(-60C to 95C)

Thread
Type
& Size

F1/F

Clearance
Hole

Body
Length

Thread
Length

Wrench
Flats

Inches (mm)

+ .01
(+.25 mm)

(Dome)

(Standard &
Low Temp.)

CD09NA-MX
CD09NR-MX
CD13NA-MX
CD13NR-MX
CD21NA-MX
CD21NR-MX
CD29NA-MX
CD29NR-MX

CC09NA-MX
CC09NR-MX
CC13NA-MX
CC13NR-MX
CC21NA-MX
CC21NR-MX
CC29NA-MX
CC29NR-MX

.16 - .31 (4 - 8)
.08 - .24 (2 - 6)
.24 - .47 (6 - 12)
.20 - .35 (5 - 9)
.55 - .71 (14 - 18)
.39 - .63 (10 - 16)
.79 - .98 (20 - 25)
.51 - .79 (13 - 20)

.83 (21)

.59 (15)

.67 (17) / .75 (19)

1/2 NPT .83 (21.1) .94 (24)

.51 (13)

.87 (22) / .94 (24)

3/4 NPT 1.05 (26.7) .98 (25)

.51 (13)

1.18 (30)

1 NPT 1.35 (34.3) 1.14 (29)

.75 (19)

1.57 (40)

Page 59
for Thread
Specs

3/8 NPT .68 (17.2)

(MX)

Nylon Spline

Elongated MetricThreads are recommended


where the Cable Gland has to pass through a
thick wall or the application just needs the
Extra Thread Length.

Buna-N
O-Ring (Included)

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Buna-N Form
Seal Insert

Ex-e Multi-Hole &


Romex Glands

Ex-e
Nylon Glands

(Low Temp.)

Dimensions in Inches (mm)


A

-60C

(Standard)

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Nickel Plated Brass Cable Glands for Hazardous Duty Locations, Low Temperature, V0, UL94, NEMA 6, 150 PSIG,
IP 68/69K, 10 BAR

Nickel Plated Brass Cable Glands for Hazardous Duty Locations, Low Temperature, Protection Class V0, UL94, NEMA 6, 150 PSIG, IP 68/69K, 10 BAR
Part Numbers
-4F to 203F
(-20C to 95C)

-76F to 203F
(-60C to 95C)

Cable Range
-4F to 203F
(-20C to 95C)

Thread
Type
& Size

F1/F

Clearance
Hole

Body
Length

Thread
Length

Thread
Length

Wrench
Flats

Page 59
for Thread
Specs

(Low Temp. )

(Elongated)

CD12MA-MX
CD12MR-MX
CD16MA-MX

CC12MA-MX
CC12MR-MX
CC16MA-MX

CD12DA-MX
CD12DR-MX
CD16DA-MX

CD16MR-MX
CD17MA-MX
CD17MR-MX
CD20MA-MX
CD20MR-MX
CD22MA-MX
CD22MR-MX
CD25MA-MX
CD25MR-MX
CD32MA-MX
CD32MR-MX
CD40MA-MX
CD40MR-MX
CD50MA-MX
CD50MR-MX
CD63MA-MX
CD63MR-MX

CC16MR-MX
CC17MA-MX
CC17MR-MX
CC20MA-MX
CC20MR-MX
CC22MA-MX
CC22MR-MX
CC25MA-MX
CC25MR-MX
CC32MA-MX
CC32MR-MX
CC40MA-MX
CC40MR-MX
CC50MA-MX
CC50MR-MX
CC63MA-MX
CC63MR-MX

CD16DR-MX
CD17DA-MX
CD17DR-MX
CD20DA-MX
CD20DR-MX
CD22DA-MX
CD22DR-MX
CD25DA-MX
CD25DR-MX
CD32DA-MX
CD32DR-MX
CD40DA-MX
CD40DR-MX
CD50DA-MX
CD50DR-MX
CD63DA-MX
CD63DR-MX

Inches (mm)

+ .01
(+.25 mm)

(Dome)

(Standard &
Low Temp.)

(Elongated)

.12 - .26 (3 - 6.5)


.08 - .20 (2 - 5)
.16 - .31 (4 - 8)
.08 - .24 (2 - 6)
.24 - .39 (6 - 10)
.12 - .28 (3 - 7)
.24 - .47 (6 - 12)
.20 - .35 (5 - 9)
.39 - .55 (10 - 14)
.28 - .47 (7 - 12)
.55 - .71 (14 - 18)
.39 - .63 (10 - 16)
.79 - .98 (20 - 25)
.51 - .79 (13 - 20)
.87 - 1.26 (22 - 32)
.79 - 1.02 (20 - 26)
1.26 - 1.50 (32 - 38)
.98 - 1.22 (25 - 31)
1.46 - 1.73 (37 - 44)
1.14 - 1.38 (29 - 35)

M12 x 1.5

.47 (12)

.75 (19)

.26 (6.5)

.39 (10)

.55 (14)

M16 x 1.5

.63 (16)

.83 (21)

.24 (6)

.39 (10)

.67 (17) /
.75 (19)

M16 x 1.5

.63 (16)

.87 (22)

.24 (6)

.39 (10)

.79 (20)

M20 x 1.5

.79 (20)

.91 (23)

.24 (6)

.39 (10)

.87 (22)

M20 x 1.5

.79 (20)

.94 (24)

.24 (6)

.39 (10)

.94 (24)

M25 x 1.5

.98 (25)

1.02 (26)

.28 (7)

.47 (12)

1.18 (30)

M32 x 1.5 1.26 (32)

1.22 (31)

.31 (8)

.47 (12)

1.57 (40)

M40 x 1.5 1.57 (40) 1.46 (37)

.31 (8)

.59 (15)

1.97 (50)

M50 x 1.5 1.97 (50)

1.46 (37)

.35 (9)

.59 (15)

2.24 (57)

M63 x 1.5 2.48 (63)

1.50 (38)

.39 (10)

.59 (15)

2.52 (64) /
2.68 (68)

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

www.sealconex.com

35

Technical
Information

Ex-e / Ex-d
Accessories

Ex-e Conduit &


Fitting Systems

Ex-e EMI / RFI Nickel


Plated Brass Glands

-60C

(Standard)

Dimensions in Inches (mm)

Ex-d EXIOS
Cable Glands

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Ex-e
Nylon Glands

Ex-e Multi-Hole &


Romex Glands

II 2G 1D

Nickel Plated Brass Cable Glands - Low Temperature


PG / PG Elongated - UL / UR / CSA / ATEX / IECEx / Ex-e
For Non-Armored Cable

Nickel Plated Brass Cable Glands for Hazardous Duty Locations, Low Temperature, V0, UL94, NEMA 6, 150 PSIG, IP 69K, 10 BAR
Part Numbers
-4F to 203F
(-20C to 95C)

-78F to 203F
(-60C to 95C)

Cable Range
-4F to 203F
(-20C to 95C)

(Standard)

(Low Temp.)

(Elongated)

(Elongated Low Temp.)

Inches (mm)

CD07AA-MX
CD07AR-MX
CD09AA-MX
CD09AR-MX
CD11AA-MX
CD11AR-MX
CD13AA-MX
CD13AR-MX
CD16AA-MX
CD16AR-MX
CD21AA-MX
CD21AR-MX
CD29AA-MX
CD29AR-MX
CD36AA-MX
CD36AR-MX
CD42AA-MX
CD42AR-MX
CD48AA-MX
CD48AR-MX

CC07AA-MX
CC07AR-MX
CC09AA-MX
CC09AR-MX
CC11AA-MX
CC11AR-MX
CC13AA-MX
CC13AR-MX
CC16AA-MX
CC16AR-MX
CC21AA-MX
CC21AR-MX
CC29AA-MX
CC29AR-MX
CC36AA-MX
CC36AR-MX
CC42AA-MX
CC42AR-MX
CC48AA-MX
CC48AR-MX

CD07CA-MX
CD07CR-MX
CD09CA-MX
CD09CR-MX
CD11CA-MX
CD11CR-MX
CD13CA-MX
CD13CR-MX
CD16CA-MX
CD16CR-MX
CD21CA-MX
CD21CR-MX
CD29CA-MX
CD29CR-MX
CD36CA-MX
CD36CR-MX
CD42CA-MX
CD42CR-MX
CD48CA-MX
CD48CR-MX

CC07CA-MX
CC07CR-MX
CC09CA-MX
CC09CR-MX
CC11CA-MX
CC11CR-MX
CC13CA-MX
CC13CR-MX
CC16CA-MX
CC16CR-MX
CC21CA-MX
CC21CR-MX
CC29CA-MX
CC29CR-MX
CC36CA-MX
CC36CR-MX
CC42CA-MX
CC42CR-MX
CC48CA-MX
CC48CR-MX

.12 - .26 (3 - 6.5)


.08 - .20 (2 - 5)
.16 - .31 (4 - 8)
.08 - .24 (2 - 6)
.24 - .39 (6 - 10)
.12 - .28 (3 - 7)
.24 - .47 (6 - 12)
.20 - .35 (5 - 9)
.39 - .55 (10 - 14)
.28 - .47 (7 - 12)
.55 - .71 (14 - 18)
.39 - .63 (10 - 16)
.79 - .98 (20 - 25)
.51 - .79 (13 - 20)
.87 - 1.26 (22 - 32)
.79 - 1.02 (20 - 26)
1.26 - 1.50 (32 - 38)
.98 - 1.22 (25 - 31)
1.46 - 1.73 (37 - 44)
1.14 - 1.38 (29 - 35)

Dimensions in Inches (mm)


A

F1/F

Clearance
Hole

Body
Length

Thread
Length

Thread
Length

Wrench
Flats

Page 59
for Thread
Specs

+ .01
(+.25 mm)

(Dome)

(Standard)

(Elongated &
Low Temp.)

PG 7

.49 (12.5)

.75 (19)

.20 (5)

.39 (10)

.55 (14)

PG 9

.60 (15.2)

.83 (21)

.24 (6)

.39 (10)

.67 (17)

PG 11

.73 (18.5) .87 (22)

.24 (6)

.39 (10)

.79 (20)

PG 13

.80 (20.3) .94 (24) .26 (6.5)

.39 (10)

.87 (22)

PG 16

.89 (22.5) .91 (23) .26 (6.5)

.39 (10)

.94 (24)

PG 21

1.12 (28.4) .94 (24)

.28 (7)

.47 (12)

1.18 (30)

PG 29

1.47 (37.3) 1.14 (29) .31 (8)

.47 (12)

1.57 (40)

PG 36

1.85 (47) 1.38 (35) .31 (8)

.59 (15)

1.97 (50)

PG 42

2.13 (54.1) 1.46 (37) .35 (9)

.59 (15)

2.24 (57)

PG 48

2.34 (59.4) 1.50 (38) .39 (10)

.59 (15)

2.52 (64)

(MX)

Nylon Spline

Ex-e Conduit &


Fitting Systems

Buna-N Form
Seal Insert

Buna-N
O-Ring (Included)

Elongated PG Threads are recommended where


the Cable Gland has to pass through a thick wall
or the application just needs the Extra Thread
Length.

Ex-e / Ex-d
Accessories

Technical
Information

-78F to 203F
(-60C to 95C)

Thread
Type
& Size

-60C

-60C

Ex-e EMI / RFI Nickel


Plated Brass Glands

Ex-e Nickel Plated Brass &


Stainless Steel Glands

ATEX

36

www.sealconex.com

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

II 2G 1D

Ex-d EXIOS
Cable Glands

Nickel Plated Brass Cable Glands with (MZ) Clamp


NPT / Metric / PG - UL / UR / CSA / ATEX / IECEx / Ex-e

ATEX

For Non-Armored Cable

Part Numbers
-4F to 203F
(-20C to 95C)

Cable Range

Thread
Type
& Size

-4F to 266F
(-20C to 130C)

Dimensions in Inches (mm)


A

F1/F

Clearance
Hole

Body
Length

Thread
Length

Wrench
Flats

+ .01
(+.25 mm)

3/8 NPT
1/2 NPT
3/4 NPT
1 NPT

.68 (17.2)
.83 (21.1)
1.05 (26.7)
1.35 (34.3)

(Clamp)
1.10 (28)
1.30 (33)
1.46 (37)
1.69 (43)

.59 (15)
.51 (13)
.51 (13)
.75 (19)

.67 (17) / .75 (19)


.87 (22) / .94 (24)
1.18 (30)
1.57 (40)

CD12MA-EZ
CD16MA-EZ
CD17MA-EZ
CD20MA-EZ
CD22MA-EZ
CD25MA-EZ
CD32MA-EZ
CD40MA-EZ
CD50MA-EZ
CD63MA-EZ

CD12MA-EZ-V
CD16MA-EZ-V
CD17MA-EZ-V
CD20MA-EZ-V
CD22MA-EZ-V
CD25MA-EZ-V
CD32MA-EZ-V
CD40MA-EZ-V
-

.12 - .26 (3 - 6.5)


.16 - .31 (4 - 8)
.24 - .39 (6 - 10)
.24 - .47 (6 - 12)
.39 - .55 (10 - 14)
.55 - .71 (14 - 18)
.79 - .98 (20 - 25)
.94 - 1.26 (24 - 32)
1.26 - 1.50 (32 - 38)
1.46 - 1.73 (37 - 44)

M12 x 1.5
M16 x 1.5
M16 x 1.5
M20 x 1.5
M20 x 1.5
M25 x 1.5
M32 x 1.5
M40 x 1.5
M50 x 1.5
M63 x 1.5

.47 (12)
.63(16)
.73 (16)
.79 (20)
.79 (20)
.98 (25)
1.26 (32)
1.57 (40)
1.97 (50)
2.48 (63)

1.02 (26)
1.10 (28)
1.18 (30)
1.30 (33)
1.30 (33)
1.46 (37)
1.69 (43)
1.97 (50)
2.01 (51)
2.04 (52)

.26 (6.5)
.24 (6)
.24 (6)
.24 (6)
.24 (6)
.28 (7)
.31 (8)
.31 (8)
.35 (9)
.39 (10)

.55 (14)
.75 (19)
.79 (20)
.87 (22)
.94 (24)
1.18 (30)
1.57 (40)
1.97 (50)
2.24 (57)
2.52 (64) / 2.68 (68)

CD07AA-EZ
CD09AA-EZ
CD11AA-EZ
CD13AA-EZ
CD16AA-EZ
CD21AA-EZ
CD29AA-EZ
CD36AA-EZ
CD42AA-EZ
CD48AA-EZ

CD07AA-EZ-V
CD09AA-EZ-V
CD11AA-EZ-V
CD13AA-EZ-V
CD16AA-EZ-V
CD21AA-EZ-V
CD29AA-EZ-V
CD36AA-EZ-V
CD42AA-EZ-V
CD48AA-EZ-V

.12 - .26 (3 - 6.5)


.16 - .31 (4 - 8)
.24 - .39 (6 - 10)
.28 - .47 (7 - 12)
.39 - .55 (10 - 14)
.51 - .71 (13 - 18)
.79 - .98 (20 - 25)
.94 - 1.26 (24 - 32)
1.26 - 1.50 (32 - 38)
1.46 - 1.73 (37 - 44)

PG 7
PG 9
PG 11
PG 13
PG 16
PG 21
PG 29
PG 36
PG 42
PG 48

.49 (12.5)
.60 (15.2)
.73 (18.5)
.80 (20.3)
.89 (22.5)
1.12 (28.4)
1.47 (37.3)
1.85 (47)
2.13 (54.1)
2.34 (59.4)

1.02 (26)
1.10 (28)
1.14 (29)
1.30 (33)
1.30 (33)
1.46 (37)
1.69 (43)
1.97 (50)
2.01 (51)
2.04 (52)

.20 (5)
.24 (6)
.24 (6)
.24 (6)
.24 (6)
.28 (7)
.31 (8)
.31 (8)
.35 (9)
.39 (10)

.55 (14)
.67 (17)
.79 (20)
.87 (22)
.94 (24)
1.18 (30)
1.57 (40)
1.97 (50)
2.24 (57)
2.52 (64)

Ex-e EMI / RFI Nickel


Plated Brass Glands

CD09NA-EZ-V
CD13NA-EZ-V
CD21NA-EZ-V
-

Ex-e Nickel Plated Brass &


Stainless Steel Glands

CD09NA-EZ
CD13NA-EZ
CD21NA-EZ
CD29NA-EZ

Inches (mm)
.16 - .31 (4 - 8)
.28 - .47 (7 - 12)
.51 - .71 (13 - 18)
.79 - .98 (20 - 25)

Ex-e Multi-Hole &


Romex Glands

(Clamp w/ FPM)

Ex-e
Nylon Glands

Page 59
for Thread
Specs

(Clamp w/ Buna-N)

(EZ-V)

(EZ)
Buna-N
O-Ring (Included)

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Nickel Plated Brass Cable Glands with MZ Clamp for Hazardous Duty Locations, Nylon/PVDF Splines with Buna-N/ FPM Inserts
Inserts, V0, NEMA 6, 150
PSIG, IP 68/69K, 10 BAR

FPM
Form Seal
Inserts

PVDF Spline

Ex-e Conduit &


Fitting Systems

Nylon Spline

FPM
O-Rings
(Included)

Buna-N Form
Seal Insert

Ex-e / Ex-d
Accessories

Nickel Plated Brass with MZ Clamps


Extra Pull-out Resistance and Cable
torque prevention

www.sealconex.com

37

Technical
Information

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Elongated Thread is
recommend where the
Cable Glands has to pass
through a thick wall or the
application just needs the
Extra Thread Length.

Nickel Plated Brass Cable Glands for Hazardous Duty Locations, PVDF Spline with FPM Insert
Insert, V0, UL94, NEMA 6,
150 PSIG, IP 68/69K, 10 BAR
Part Numbers

Cable Range

Thread
Type
& Size

-4F to 266F
(-20C to 130C)

Ex-d EXIOS
Cable Glands

Ex-e Multi-Hole &


Romex Glands

(Standard)

Inches (mm)

CD09NA-RX
CD09NR-RX
CD13NA-RX
CD13NR-RX
CD21NA-RX
CD21NR-RX

.16 - .31 (4 - 8)
.08 - .24 (2 - 6)
.24 - .47 (6 - 12)
.20 - .35 (5 - 9)
.55 - .71 (14 - 18)
.39 - .63 (10 - 16)

Ex-e Nickel Plated Brass &


Stainless Steel Glands

FPM Form
Seal Inserts

PVDF Spline

Dimensions in Inches (mm)


A

F1/F

Clearance
Hole

Body
Length

Thread
Length

Wrench
Flats

Page 59
for Thread
Specs

+ .01
(+.25 mm)

(Dome)

(Standard)

3/8 NPT

.68 (17.2)

.83 (21)

.59 (15)

.67 (17) /
.75 (19)

1/2 NPT

.83 (21.1)

.94 (24)

.51 (13)

.87 (22) /
.94 (24)

3/4 NPT

1.05 (26.7)

.98 (25)

.51 (13)

1.18 (30)

FPM
O-Rings
(Included)

(RX)

PVDF is Ideal for Higher Temperature Applications!

Nickel Plated Brass Cable Glands for Hazardous Duty Locations, PVDF Spline with FPM Insert
Insert, V0, UL94, NEMA 6, 150 PSIG, IP 68/69K, 10 BAR

Ex-e EMI / RFI Nickel


Plated Brass Glands

Part Numbers

Ex-e Conduit &


Fitting Systems

-4F to 266F
(-20C to 130C)

Ex-e / Ex-d
Accessories

Technical
Information

Nickel Plated Brass Cable Glands (PVDF) Spline


NPT / Metric - UL / UR / CSA / ATEX / IECEx / Ex-e

II 2G 1D

For Non-Armored Cable

Ex-e
Nylon Glands

Ex-d Nickel Plated Brass &


Stainless Steel Glands

ATEX

38

Cable Range

-4F to 266F
(-20C to 130C)

(Standard)

(Elongated)

Inches (mm)

CD12MA-RX
CD12MR-RX
CD16MA-RX
CD16MR-RX
CD17MA-RX
CD17MR-RX
CD20MA-RX
CD20MR-RX
CD22MA-RX
CD22MR-RX
CD25MA-RX
CD25MR-RX
CD32MA-RX
CD32MR-RX
CD40MA-RX
CD40MR-RX

CD12DA-RX
CD12DR-RX
CD16DA-RX
CD16DR-RX
CD17DA-RX
CD17DR-RX
CD20DA-RX
CD20DR-RX
CD22DA-RX
CD22DR-RX
CD25DA-RX
CD25DR-RX
CD32DA-RX
CD32DR-RX
CD40DA-RX
CD40DR-RX

.12 - .26 (3 - 6.5)


.08 - .20 (2 - 5)
.16 - .31 (4 - 8)
.08 - .24 (2 - 6)
.24 - .39 (6 - 10)
.12 - .28 (3 - 7)
.24 - .47 (6 - 12)
.20 - .35 (5 - 9)
.39 - .55 (10 - 14)
.28 - .47 (7 - 12)
.55 - .71 (14 - 18)
.39 - .63 (10 - 16)
.79 - .98 (20 - 25)
.51 - .79 (13 - 20)
.87 - 1.26 (22 - 32)
.79 - 1.02 (20 - 26)

www.sealconex.com

Thread
Type
& Size

Dimensions in Inches (mm)


A

F1/F

Clearance
Hole

Body
Length

Thread
Length

Thread
Length

Wrench
Flats

Page 59
for Thread
Specs

+ .01
(+.25 mm)

(Dome)

(Standard)

(Elongated)

M12 x 1.5

.47 (12)

.75 (19)

.26 (6.5)

.39 (10)

.55 (14)

M16 x 1.5

.63 (16)

.83 (21)

.24 (6)

.39 (10)

.67 (17) /
.75 (19)

M16 x 1.5

.63 (16)

.87 (22)

.24 (6)

.39 (10)

.79 (20)

M20 x 1.5

.79 (20)

.91 (23)

.24 (6)

.39 (10)

.87 (22)

M20 x 1.5

.79 (20)

.94 (24)

.24 (6)

.39 (10)

.94 (24)

M25 x 1.5

.98 (25)

1.02 (26)

.28 (7)

.47 (12)

1.18 (30)

M32 x 1.5

1.26 (32)

1.22 (31)

.31 (8)

.47 (12)

1.57 (40)

M40 x 1.5

1.57 (40)

1.46 (37)

.31 (8)

.59 (15)

1.97 (50)

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

II 2G 1D

Nickel Plated Brass Cable Glands (PVDF) Spline


PG / PG Elong. - UL / UR / CSA / ATEX / IECEx / Ex-e

Ex-d EXIOS
Cable Glands

ATEX

For Non-Armored Cable


Part Numbers
-4F to 266F
(-20C to 130C)

Cable Range

Thread
Type
& Size

-4F to 266F
(-20C to 130C)

F1/F

Clearance
Hole

Body
Length

Thread
Length

Thread
Length

Wrench
Flats

Inches (mm)

+ .01
(+.25 mm)

(Dome)

(Standard)

(Elongated)

CD07AA-RX
CD07AR-RX
CD09AA-RX
CD09AR-RX
CD11AA-RX
CD11AR-RX
CD13AA-RX
CD13AR-RX
CD16AA-RX
CD16AR-RX
CD21AA-RX
CD21AR-RX
CD29AA-RX
CD29AR-RX
CD36AA-RX
CD36AR-RX
CD42AA-RX
CD42AR-RX
CD48AA-RX
CD48AR-RX

CD07CA-RX
CD07CR-RX
CD09CA-RX
CD09CR-RX
CD11CA-RX
CD11CR-RX
CD13CA-RX
CD13CR-RX
CD16CA-RX
CD16CR-RX
CD21CA-RX
CD21CR-RX
CD29CA-RX
CD29CR-RX
CD36CA-RX
CD36CR-RX
CD42CA-RX
CD42CR-RX
CD48CA-RX
CD48CR-RX

.12 - .26 (3 - 6.5)


.08 - .20 (2 - 5)
.16 - .31 (4 - 8)
.08 - .24 (2 - 6)
.24 - .39 (6 - 10)
.12 - .28 (3 - 7)
.24 - .47 (6 - 12)
.20 - .35 (5 - 9)
.39 - .55 (10 - 14)
.28 - .47 (7 - 12)
.55 - .71 (14 - 18)
.39 - .63 (10 - 16)
.79 - .98 (20 - 25)
.51 - .79 (13 - 20)
.87 - 1.26 (22 - 32)
.79 - 1.02 (20 - 26)
1.26 - 1.50 (32 - 38)
.98 - 1.22 (25 - 31)
1.46 - 1.73 (37 - 44)
1.14 - 1.38 (29 - 35)

PG 7

.49 (12.5)

.75 (19)

.20 (5)

.39 (10)

.55 (14)

PG 9

.60 (15.2)

.83 (21)

.24 (6)

.39 (10)

.67 (17)

PG 11

.73 (18.5)

.87 (22)

.24 (6)

.39 (10)

.79 (20)

PG 13

.80 (20.3)

.94 (24)

.26 (6.5)

.39 (10)

.87 (22)

PG 16

.89 (22.5)

.91 (23)

.26 (6.5)

.39 (10)

.94 (24)

PG 21

1.12 (28.4)

.94 (24)

.28 (7)

.47 (12)

1.18 (30)

PG 29

1.47 (37.3)

1.14 (29)

.31 (8)

.47 (12)

1.57 (40)

PG 36

1.85 (47)

1.38 (35)

.31 (8)

.59 (15)

1.97 (50)

PG 42

2.13 (54.1)

1.46 (37)

.35 (9)

.59 (15)

2.24 (57)

PG 48

2.34 (59.4)

1.50 (38)

.39 (10)

.59 (15)

2.52 (64)

PVDF Spline

(RX)

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Ex-e Multi-Hole &


Romex Glands

Ex-e
Nylon Glands

(Elongated)

FPM Form Seal


Inserts

Dimensions in Inches (mm)

Page 59
for Thread
Specs

(Standard)

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Nickel Plated Brass Cable Glands for Hazardous Duty Locations, PVDF Splines with FPM Insert
Insert, V0, UL94, NEMA 6, 150 PSIG, IP 68/69K, 10 BAR

FPM
O-Rings
(Included)

Ex-e EMI / RFI Nickel


Plated Brass Glands

PVDF is Ideal for Higher Temperature Applications!

Ex-e Conduit &


Fitting Systems

www.sealconex.com

39

Technical
Information

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Ex-e / Ex-d
Accessories

Elongated Thread is recommended where the Cable Gland


has to pass through a thick wall or the application just
needs the Extra Thread Length.

Ex-d EXIOS
Cable Glands

(303) Stainless Steel Cable Glands - Low Temperature


Metric / PG - UL / UR / CSA / ATEX / IECEx / Ex-e

II 2G 1D
*

For Non-Armored Cable


(303) Stainless Steel (INOX) Cable Glands for Hazardous Duty Locations, Low Temperature, Nylon/PVDF Clamping Spline with Buna-N/ FPM
Inserts, V0, NEMA 6, 150 PSIG, IP 68/69K, 10 BAR
Part Numbers
-4F to 203F
(-20C to 95C)

Cable Range

-78F to 203F
(-60C to 95C)

-4F to 266F
(-20C to 130C)

Ex-e Multi-Hole &


Romex Glands

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Ex-e EMI / RFI Nickel


Plated Brass Glands

(Nylon Spline w/ Buna-N)

(Nylon Spline Low Temp.)

(PVDF Spline w/ FPM)

Inches (mm)

CD12MA-SX
CD12MR-SX
CD17MA-SX
CD17MR-SX
CD22MA-SX
CD22MR-SX
CD25MA-SX
CD25MR-SX
CD32MA-SX
CD32MR-SX
CD40MA-SX
CD40MR-SX

CC12MA-SX
CC12MR-SX
CC17MA-SX
CC17MR-SX
CC22MA-SX
CC22MR-SX
CC25MA-SX
CC25MR-SX
CC32MA-SX
CC32MR-SX
CC40MA-SX
CC40MR-SX

CD12MA-SX-V
CD12MR-SX-V
CD17MA-SX-V
CD17MR-SX-V
CD22MA-SX-V
CD22MR-SX-V
CD25MA-SX-V
CD25MR-SX-V
CD32MA-SX-V
CD32MR-SX-V
CD40MA-SX-V
CD40MR-SX-V

.12 - .26 (3 - 6.5)


.08 - .20 (2 - 5)
.20 - .39 (5 - 10)
.12 - .28 (3 - 7)
.39 - .55 (10 - 14)
.28 - .47 (7 - 12)
.51 - .71 (13 - 18)
.35 - .63 (9 - 16)
.79 - .98 (20 - 25)
.51 - .79 (13 - 20)
.87 - 1.26 (22 - 32)
.79 - 1.02 (20 - 26)

CD07AA-SX
CD07AR-SX
CD09AA-SX
CD09AR-SX
CD11AA-SX
CD11AR-SX
CD13AA-SX
CD13AR-SX
CD16AA-SX
CD16AR-SX
CD21AA-SX
CD21AR-SX
CD29AA-SX
CD29AR-SX
CD36AA-SX
CD36AR-SX

CC07AA-SX
CC07AR-SX
CC09AA-SX
CC09AR-SX
CC11AA-SX
CC11AR-SX
CC13AA-SX
CC13AR-SX
CC16AA-SX
CC16AR-SX
CC21AA-SX
CC21AR-SX
CC29AA-SX
CC29AR-SX
CC36AA-SX
CC36AR-SX

CD07AA-SX-V
CD07AR-SX-V
CD09AA-SX-V
CD09AR-SX-V
CD11AA-SX-V
CD11AR-SX-V
CD13AA-SX-V
CD13AR-SX-V
CD16AA-SX-V
CD16AR-SX-V
CD21AA-SX-V
CD21AR-SX-V
CD29AA-SX-V
CD29AR-SX-V
CD36AA-SX-V
CD36AR-SX-V

.12 - .26 (3 - 6.5)


.08 - .20 (2 - 5)
.16 - .31 (4 - 8)
.08 - .24 (2 - 6)
.20 - .39 (5- 10)
.12 - .28 (3 - 7)
.24 - .47 (6 - 12)
.20 - .35 (5 - 9)
.39 - .55 (10 - 14)
.28 - .47 (7 - 12)
.51 - .71 (13 - 18)
.35 - .63 (9 - 16)
.79 - .98 (20 - 25)
.51 - .79 (13 - 20)
.87 - 1.26 (22 - 32)
.79 - 1.02 (20 - 26)

Dimensions in Inches (mm)


A

Clearance
Hole

Body
Length

Thread
Length

Wrench
Flats

Page 59
for Thread
Specs

+ .01
(+.25 mm)

(Dome)

M12 x 1.5

.47 (12)

.75 (19)

.26 (6.5)

.55 (14)

M16 x 1.5

.63 (16)

.87 (22)

.24 (6)

.87 (22)

M20 x 1.5

.79 (20)

.91 (23)

.24 (6)

.94 (24)

M25 x 1.5

.98 (25)

.94 (24)

.28 (7)

1.18 (30)

M32 x 1.5

1.26 (32)

1.14 (29)

.31 (8)

1.61 (41)

M40 x 1.5

1.57 (40)

1.38 (35)

.31 (8)

1.97 (50)

PG 7

.49 (12.5)

.75 (19)

.20 (5)

.55 (14)

PG 9

.60 (15.2)

.83 (21)

.24 (6)

.67 (17)

PG 11

.73 (18.5)

.87 (22)

.24 (6)

.87 (22)

PG 13

.80 (20.3)

.94 (24)

.24 (6)

.87 (22)

PG 16

.89 (22.5)

.91 (23)

.24 (6)

.94 (24)

PG 21

1.12 (28.4)

.94 (24)

.28 (7)

1.18 (30)

PG 29

1.47 (37.3)

1.14 (29)

.31 (8)

1.61 (41)

PG 36

1.85 (47)

1.38 (35)

.31 (8)

1.97 (50)

*CE & CSA apply to all SX style cable glands.

Ex-e Conduit &


Fitting Systems

(SX)

Buna-N Form
Seal Insert

Nylon Spline

Buna-N
O-Ring (Included)

Also available 316L Stainless Steel


e.g.- CDxxxx-6X & CDxxxx-6X-V
See more information online

Nylon is Ideal for Lower Temperature Applications!

(SX-V)

Ex-e / Ex-d
Accessories

Technical
Information

Thread
Type
& Size

-60C

Ex-e
Nylon Glands

Ex-d Nickel Plated Brass &


Stainless Steel Glands

ATEX

FPM Form
Seal Insert

PVDF Spline

FPM
O-Rings
(Included)

PVDF is Ideal for Higher Temperature Applications!


40

www.sealconex.com

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

II 2G 1D

EMI / RFI (Braided) Nickel Plated Brass Cable Glands


(Low Temp.) - NPT / Metric - CSA / ATEX / IECEx / Ex-e

Ex-d EXIOS
Cable Glands

ATEX

For Non-Armored Braided Cable


Part Numbers
-4F to 203F
(-20C to 95C)

Cable Range

-76F to 203F
(-60C to 95C)

Thread
Type
& Size

-4F to 266F
(-20C to 130C)

F1/F

Clearance
Hole

Body
Length

Thread
Length

Wrench
Flats

Page 59
for Thread
Specs

(PVDF Spline w/ FPM)

CD09NA-EX
CD09NR-EX
CD13NA-EX
CD13NR-EX
CD21NA-EX
CD21NR-EX

CC09NA-EX
CC09NR-EX
CC13NA-EX
CC13NR-EX
CC21NA-EX
CC21NR-EX

CD09NA-EX-V
CD09NR-EX-V
CD13NA-EX-V
CD13NR-EX-V
CD21NA-EX-V
CD21NR-EX-V

Inches (mm)
.16 - .31 (4 - 8)
.08 - .24 (2 - 6)
.24 - .47 (6 - 12)
.20 - .35 (5 - 9)
.55 - .71 (14 - 18)
.39 - .63 (10 - 16)

+ .01
(+.25 mm)

(Dome)

3/8 NPT

.68 (17.2)

.83 (21)

.59 (15)

.67 (17) / .75 (19)

1/2 NPT

.83 (21.1)

.94 (24)

.51 (13)

.87 (22) / .94 (24)

3/4 NPT 1.05 (26.7) .98 (25)

.51 (13)

1.18 (30)

CD12MA-EX

CC12MA-EX

.12 - .26 (3 - 6.5)

CD12MR-EX

CC12MR-EX

.08 - .20 (2 - 5)

M12 x 1.5

.47 (12)

.75 (19)

.26 (6.5)

.55 (14)

CD17MA-EX

CC17MA-EX

.24- .39 (6 - 10)

CD17MR-EX

CC17MR-EX

.12 - .27 (3 - 7)

M16 x 1.5

.63 (16)

.87 (22)

.24 (6)

.79 (20)

.39 - .55 (10- 14)

.27 - .47 (7 - 12)

M20 x 1.5

.79 (20)

.91 (23)

.24 (6)

.94 (24)

CD25MA-EX

CC25MA-EX

.55 - .71 (14 - 18)

CD25MR-EX

CC25MR-EX

.39 - .63 (10 - 16)

M25 x 1.5

.98 (25)

.94 (24)

.28 (7)

1.18 (30)

CD32MA-EX

CC32MA-EX

.79 - .98 (20 - 25)

CD32MR-EX

CC32MR-EX

.51 - .79 (13 - 20)

M32 x 1.5

1.26 (32)

1.22 (31)

.31 (8)

1.57 (40)

CD40MA-EX

CC40MA-EX

.87 - 1.26 (22 - 32)

CD40MR-EX

CC40MR-EX

.79 - 1.02 (20 - 26)

M40 x 1.5

1.57 (40)

1.46 (37)

.31 (8)

1.97 (50)

CD50MA-EX

CC50MA-EX

1.26 - 1.50 (32 - 38)

CD50MR-EX

CC50MR-EX

.98 - 1.22 (25 - 31)

M50 x 1.5

1.97 (50)

1.46 (37)

.35 (9)

2.24 (57)

CD63MA-EX

CC63MA-EX

1.46 - 1.73 (37 - 44)

CD63MR-EX

CC63MR-EX

1.14 - 1.38 (29 - 35)

M63 x 1.5

2.48 (63)

1.50 (38)

.39 (10)

2.52 (64) /
2.68 (68)

Buna-N
Form Seal
Insert

FPM Form
Seal Insert

Elongated Threads are also available in Metric Stainless Steel

Buna-N
O-Ring

Ex-e Conduit &


Fitting Systems

The Standard version has an integral O-ring, which


presses the braiding against the inside wall of the
body. Can only be used with braided shield.

Nylon
Spline
Buna-N
O-Ring
(Included)

*CE apply to all -EX style cable glands.

PVDF (-EX-V)

Standard (-EX)

Ex-e EMI / RFI Nickel


Plated Brass Glands

CC22MA-EX
CC22MR-EX

Ex-e Nickel Plated Brass &


Stainless Steel Glands

CD22MA-EX
CD22MR-EX

Ex-e Multi-Hole &


Romex Glands

Ex-e
Nylon Glands

(Nylon Spline Low Temp.)

Dimensions in Inches (mm)


A

-60C

(Nylon Spline w/ Buna-N)

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Nickel Plated Brass


Brass, Cable Glands EMI/RFI Proof for Braided Cables for Hazardous Duty Locations, Low Temperatures, Nylon/PVDF Spline with
Buna-N & FPM Inserts, V0, UL94, NEMA 6, 150 PSIG, IP 68/69K, 10 BAR

PVDF
Spline

Ex-e / Ex-d
Accessories

FPM
O-Rings
(Included)

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

www.sealconex.com

41

Technical
Information

Patented 360 grounding due to the internal


O-Ring, ensures perfect contact between
braided shield of cable and fitting.

Ex-d EXIOS
Cable Glands

II 2G 1D

Nickel Plated Brass


Brass, Cable Glands EMI/RFI Braided Cables for Hazardous Duty Locations, Low Temperatures, Nylon/PVDF Spline with Buna-N &
FPM Inserts, V0, UL94, NEMA 6, 150 PSIG, IP 68/69K, 10 BAR
Part Numbers
-4F to 203F
(-20C to 95C)

-76F to 203F
(-60C to 95C)

Cable Range

Thread
Type
& Size

-4F to 266F
(-20C to 130C)

(Nylon Spline w/ Buna-N)

(Nylon Spline Low Temp.)

(PVDF Spline w/ FPM)

Inches (mm)

CD07AA-EX
CD07AR-EX
CD09AA-EX
CD09AR-EX
CD11AA-EX
CD11AR-EX
CD13AA-EX
CD13AR-EX
CD16AA-EX
CD16AR-EX
CD21AA-EX
CD21AR-EX
CD29AA-EX
CD29AR-EX
CD36AA-EX
CD36AR-EX
CD42AA-EX
CD42AR-EX
CD48AA-EX
CD48AR-EX

CC07AA-EX
CC07AR-EX
CC09AA-EX
CC09AR-EX
CC11AA-EX
CC11AR-EX
CC13AA-EX
CC13AR-EX
CC16AA-EX
CC16AR-EX
CC21AA-EX
CC21AR-EX
CC29AA-EX
CC29AR-EX
CC36AA-EX
CC36AR-EX
CC42AA-EX
CC42AR-EX
CC48AA-EX
CC48AR-EX

CD07AA-EX-V
CD07AR-EX-V
CD09AA-EX-V
CD09AR-EX-V
CD11AA-EX-V
CD11AR-EX-V
CD13AA-EX-V
CD13AR-EX-V
CD16AA-EX-V
CD16AR-EX-V
CD21AA-EX-V
CD21AR-EX-V
CD29AA-EX-V
CD29AR-EX-V
CD36AA-EX-V
CD36AR-EX-V
CD42AA-EX-V
CD42AR-EX-V
CD48AA-EX-V
CD48AR-EX-V

.12 - .26 (3 - 6.5)


.08 - .20 (2 - 5)
.16 - .31 (4 - 8)
.08 - .24 (2 - 6)
.24 - .39 (6 - 10)
.12 - .28 (3 - 7)
.24 - .47 (6 - 12)
.20 - .35 (5 - 9)
.39 - .55 (10 - 14)
.28 - .47 (7 - 12)
.55 - .71 (14 - 18)
.39 - .63 (10 - 16)
.79 - .98 (20 - 25)
.51 - .79 (13 - 20)
.87 - 1.26 (22 - 32)
.79 - 1.02 (20 - 26)
1.26 - 1.50 (32 - 38)
.98 - 1.22 (25 - 31)
1.46 - 1.73 (37 - 44)
1.14 - 1.38 (29 - 35)

Ex-e Multi-Hole &


Romex Glands

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Dimensions in Inches (mm)


A

Clearance
Hole

Body
Length

Thread
Length

Wrench
Flats

Page 59
for Thread
Specs

+ .01
(+.25 mm)

(Dome)

PG 7

.49 (12.5)

.75 (19)

.20 (5)

.55 (14)

PG 9

.60 (15.2)

.83 (21)

.24 (6)

.67 (17)

PG 11

.73 (18.5)

.87 (22)

.24 (6)

.79 (20)

PG 13

.80 (20.3)

.94 (24)

.26 (6.5)

.87 (22)

PG 16

.89 (22.5)

.91 (23)

.26 (6.5)

.94 (24)

PG 21

1.12 (28.4)

.94 (24)

.28 (7)

1.18 (30)

PG 29

1.47 (37.3)

1.14 (29)

.31 (8)

1.57 (40)

PG 36

1.85 (47)

1.38 (35)

.31 (8)

1.97 (50)

PG 42

2.13 (54.1)

1.46 (37)

.35 (9)

2.24 (57)

PG 48

2.34 (59.4)

1.50 (38)

.39 (10)

2.52 (64)

-60C

*CE apply to all -EX style cable glands.


Elongated Threads also available in PG

The Standard version has an integral O-Ring,


which presses the braiding against the inside
wall of the body. Can only be used with
braided shield.

Ex-e EMI / RFI Nickel


Plated Brass Glands

Standard (-EX)
PVDF (-EX-V)

Buna-N
Form Seal
Insert
FPM Form
Seal Insert

Ex-e Conduit &


Fitting Systems

Nylon
Spline

Buna-N
O-Ring
(Included)

Ex-e / Ex-d
Accessories

Technical
Information

EMI / RFI (Braided) Nickel Plated Brass Cable Glands


(Low Temp.) - PG Threads - CSA / ATEX / IECEx / Ex-e
For Non-Armored Braided Cable

Ex-e
Nylon Glands

Ex-d Nickel Plated Brass &


Stainless Steel Glands

ATEX

Buna-N
O-Ring

PVDF
Spline

FPM
O-Rings
(Included)

Patented 360 grounding due to the internal


O-Ring, ensures perfect contact between
braided shield of cable and fitting.
The patented internal sealing edge results in a superior
seal between the Nylon & PVDF clamping splines and
Nickel Plated Brass body.

42

www.sealconex.com

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

II 2G 1D

EMI / RFI (Braided / Foil) Nickel Plated Brass Glands


(Low Temp.) - Metric / PG - CSA / ATEX / IECEx / Ex-e

Ex-d EXIOS
Cable Glands

ATEX

For Non-Armored Foil & Braided Cable


Part Numbers
-4F to 203F
(-20C to 95C)

-4F to 203F
(-20C to 95C)

Cable Range
-76F to 203F
(-60C to 95C)

-76F to 203F
(-60C to 95C)

-60C

Thread
Type
& Size

-60C

Dimensions in Inches (mm)


A

Clearance
Hole

Body
Length

Thread
Length

Thread
Length

Wrench
Flats

(Standard)

(Elongated)

(Standard
Low Temp.)

(Elongated
Low Temp.)

Inches (mm)

Page 59
for Thread
Specs

CD17MA-FX
CD22MA-FX
CD25MA-FX
CD32MA-FX
CD40MA-FX

CD17DA-FX
CD22DA-FX
CD25DA-FX
CD32DA-FX
CD40DA-FX

CC17MA-FX
CC22MA-FX
CC25MA-FX
CC32MA-FX
CC40MA-FX

CC17DA-FX
CC22DA-FX
CC25DA-FX
CC32DA-FX
CC40DA-FX

.20 - .39 (5 - 10)


.39 - .55 (10 - 14)
.51 - .71 (13 - 18)
.71 - .98 (18 - 25)
.94 - 1.26 (24 - 32)

M16 x 1.5
M20 x 1.5
M25 x 1.5
M32 x 1.5
M40 x 1.5

.73 (18.5)
.89 (22.5)
1.12 (28.4)
1.47 (37.3)
1.85 (47)

(Dome) (Standard) (Elongated)


1.14 (29)
.24 (6)
.39 (10)
.79 (20)
1.22 (31)
.24 (6)
.39 (10)
.94 (24)
1.49 (38)
.28 (7)
.47 (12) 1.18 (30)
1.69 (43)
.31 (8)
.47 (12) 1.57 (40)
2.03 (51)
.31 (8)
.59 (15) 1.97 (50)

Ex-e
Nylon Glands

CD11AA-FX
CD13AA-FX
CD16AA-FX
CD21AA-FX
CD29AA-FX
CD36AA-FX

CC11AA-FX
CC13AA-FX
CC16AA-FX
CC21AA-FX
CC29AA-FX
CC36AA-FX

.20 - .39 (5 - 10)


.24 - .47 (6 - 12)
.39 - .55 (10 - 14)
.51 - .71 (13 - 18)
.71 - .98 (18 - 25)
.87 - 1.26 (22 - 32)

PG 11
PG 13
PG 16
PG 21
PG 29
PG 36

.73 (18.5)
.80 (20.3)
.89 (22.5)
1.12 (28.4)
1.47 (37.3)
1.85 (47)

1.14 (29)
1.22 (31)
1.26 (32)
1.49 (38)
1.69 (43)
1.89 (48)

Ex-e Multi-Hole &


Romex Glands

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Nickel Plated Brass


Brass, Cable Glands for EMI/RFI Braided & Foil Shielded Cables in Hazardous Duty Locations, Low Temperature, Metallized Nylon
Spline with Buna-N Inserts, V0, NEMA 6, 150 PSIG, IP 68/69K, 10 BAR

+ .01
(+.25 mm)

.24 (6)
.26 (6.5)
.26 (6.5)
.28 (7)
.31 (8)
.31 (8)

.79 (20)
.87 (22)
.94 (24)
1.18 (30)
1.57 (40)
1.97 (50)

*Note: Approval rating applies to Metric Threads only.


*CE apply to all EX style (Nylon Spline) cable glands.

Feed-Through works well with foil or braided


shield and provides reliable grounding by
means of metal spring fingers.
Overlapping clamping splines
apply a concentric force,preventing
the form seal from being pulled out
of the fitting. This ensures pull-out
protection without damage to the
cable.

Fold Shield
Over Jacket

Ex-e EMI / RFI Nickel


Plated Brass Glands

Our Metal-Coated Nylon Spline


Insert provides the higest electrical
shielding in the industry.

Total Jacket
Removal

Flexible contact points allow contact with


variable braid and foil cable diameters.

Buna-N Form
Seal Insert

Metallized
Nylon
Spline

Elongated Thread is recommended


where the Cable Glands have to pass
through a thick wall or an application
that` needs the Extra Thread Length.

Ex-e / Ex-d
Accessories

(FX)

Buna-N
O-Ring (Included)

800-456-9012

www.sealconex.com

43

Technical
Information

Use our recommened EMI Locking Nuts with


cutting edges which cut through paint to ensure
proper grounding (see page 47).
Dimensions, specifications and certifications may be changed without prior notice.

Ex-e Conduit &


Fitting Systems

Partial Jacket
Stripping

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Feed-Through (-FX)

Ex-d EXIOS
Cable Glands

II 2G 1D

EMI / RFI w/ Clamp (Braided) Nickel Plated Brass Glands


(Low Temp.) - NPT / Metric / PG - CSA / ATEX / IECEx / Ex-e
For Non-Armored Braided Cable

Nickel Plated Brass


Brass, Cable Glands for EMI/RFI Braided Cables in Hazardous Duty Locations, Low Temperature, Nylon/PVDF Spline with Buna-N &
FPM Inserts, V0, NEMA 6, 150 PSIG, IP 68/69K, 10 BAR
Part Numbers
-4F to 203F
(-20C to 95C)

-76F to 203F
(-60C to 95C)

Cable Range
-4F to 266F
(-20C to 130C)

Thread
Type
& Size

Dimensions in Inches (mm)


A

F1/F

Clearance
Hole

Body
Length

Thread
Length

Wrench
Flats

Inches (mm)

Page 59
for Thread
Specs

+ .01
(+.25 mm)

(Clamp)

(Clamp w/ Buna-N
Low Temp.)

CD09NA-EXZ
CD13NA-EXZ
CD21NA-EXZ

CC09NA-EXZ
CC13NA-EXZ
CC21NA-EXZ

CD09NA-EXZ-V
CD13NA-EXZ-V
CD21NA-EXZ-V

.16 - .31 (4 - 8)
.28 - .47 (7 - 12)
.51 - .71 (13 - 18)

3/8 NPT
1/2 NPT
3/4 NPT

.68 (17.2)
.83 (21.1)
1.05 (26.7)

1.06 (27)
1.22 (31)
1.42 (36)

.59 (15)
.51 (13)
.51 (13)

.67/.75 (17/19)
.87/.94 (22/24)
1.18 (30)

CD12MA-EXZ
CD17MA-EXZ
CD22MA-EXZ
CD25MA-EXZ
CD32MA-EXZ
CD40MA-EXZ
CD50MA-EXZ
CD50MR-EXZ
CD63MA-EXZ
CD63MR-EXZ

CC12MA-EXZ
CC17MA-EXZ
CC22MA-EXZ
CC25MA-EXZ
CC32MA-EXZ
CC40MA-EXZ
CC50MA-EXZ
CC50MR-EXZ
CC63MA-EXZ
CC63MR-EXZ

.12 - .26 (3 - 6.5)


.24 - .39 (6 - 10)
.39 - .55 (10 - 14)
.55 - .71 (14 - 18)
.79 - .98 (20 - 25)
.94 - 1.26 (24 - 32)
1.26 - 1.50 (32 - 38)
1.10 - 1.22 (28 - 31)
1.46 - 1.73 (37 - 44)
1.26 - 1.38 (32 - 35)

M12 x 1.5
M16 x 1.5
M20 x 1.5
M25 x 1.5
M32 x 1.5
M40 x 1.5

.49 (12.5)
.73 (18.5)
.89 (22.5)
1.12 (28.4)
1.47 (37.3)
1.85 (47)

1.02 (26)
1.14 (29)
1.26 (32)
1.38 (35)
1.61 (41)
1.89 (48)

.26 (6.5)
.24 (6)
.24 (6)
.28 (7)
.31 (8)
.31 (8)

.55 (14)
.79 (20)
.94 (24)
1.18 (30)
1.57 (40)
1.97 (50)

M50 x 1.5

1.85 (47)

2.01 (51)

.35 (9)

2.24 (57)

M63 x 1.5

1.85 (47)

2.04 (52)

.39 (10)

2.68 (68)

CD07AA-EXZ
CD09AA-EXZ
CD11AA-EXZ
CD13AA-EXZ
CD16AA-EXZ
CD21AA-EXZ
CD29AA-EXZ
CD36AA-EXZ
CD42AA-EXZ
CD42AR-EXZ
CD48AA-EXZ
CD48AR-EXZ

CC07AA-EXZ
CC09AA-EXZ
CC11AA-EXZ
CC13AA-EXZ
CC16AA-EXZ
CC21AA-EXZ
CC29AA-EXZ
CC36AA-EXZ
CC42AA-EXZ
CC42AR-EXZ
CC48AA-EXZ
CC48AR-EXZ

CD07AA-EXZ-V
CD09AA-EXZ-V
CD11AA-EXZ-V
CD13AA-EXZ-V
CD16AA-EXZ-V
CD21AA-EXZ-V
CD29AA-EXZ-V
CD36AA-EXZ-V
CD42AA-EXZ-V
CD42AR-EXZ-V
CD48AA-EXZ-V
CD48AR-EXZ-V

.12 - .26 (3 - 6.5)


.16 - .31 (4 - 8)
.24 - .39 (6 - 10)
.28 - .47 (7 - 12)
.39 - .55 (10 - 14)
.51 - .71 (13 - 18)
.79 - .98 (20 - 25)
.94 - 1.26 (24 - 32)
1.26 - 1.50 (32 - 38)
1.10 - 1.22 (28 - 31)
1.46 - 1.73 (37 - 44)
1.26 - 1.38 (32 - 35)

PG 7
PG 9
PG 11
PG 13
PG 16
PG 21
PG 29
PG 36

.49 (12.5)
.60 (15.2)
.73 (18.5)
.80 (20.3)
.89 (22.5)
1.12 (28.4)
1.47 (37.3)
1.85 (47)

1.02 (26)
1.10 (28)
1.14 (29)
1.30 (33)
1.26 (32)
1.38 (35)
1.61 (41)
1.89 (48)

.20 (5)
.24 (6)
.24 (6)
.26 (6.5)
.26 (6.5)
.28 (7)
.31 (8)
.31 (8)

.55 (14)
.67 (17)
.79 (20)
.87 (22)
.94 (24)
1.18 (30)
1.57 (40)
1.97 (50)

PG 42

2.13 (54.1)

2.01 (51)

.35 (9)

2.24 (57)

PG 48

2.34 (59.4)

2.01 (51)

.39 (10)

2.52 (64)

Ex-e EMI / RFI Nickel


Plated Brass Glands

Ex-e Nickel Plated Brass &


Stainless Steel Glands

(Clamp w/ Buna-N)

(Clamp w/ FPM)

Ex-e
Nylon Glands

-60C

Ex-e Multi-Hole &


Romex Glands

Ex-d Nickel Plated Brass &


Stainless Steel Glands

ATEX

*CE apply to all EX style (Nylon Spline) cable glands.

FPM Form
Seal Insert

PVDF
Clamp (-EXZ-V)

Ex-e Conduit &


Fitting Systems

FPM
O-Rings
(Included)

Buna-N
O-Ring

Standard
Clamp (-EXZ)

Buna-N
O-Ring
(Included)

Ex-e / Ex-d
Accessories

Technical
Information

PVDF Spline

Buna-N Form
Seal Insert

44

www.sealconex.com

Nickel Plated Brass MZ Clamps


Extra Pull-out Resistance
Torque Prevention on Braid

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Ex-d EXIOS
Cable Glands

Corrugated Conduit - Nylon - Snapflex-Ex


Conduit System - Metric - Ex-e

ATEX

Corrugated Conduit: Snapflex-Ex

(RAL 9005)

B
A

Snapflex-Ex
Conduit
Size

Roll
Length
feet (m)

SF-1016-BX
SF-1420-BX
SF-1825-BX
SF-2432-BX
SF-3140-BX

16
20
25
32
40

164 (50)
164 (50)
164 (50)
164 (50)
82 (25)

Dimensions

Dimensions

Inner
Diameter (A)

Outer
Diameter (B)

Inches (mm)

Inches (mm)

.42 (10.7)
.55 (14.1)
.72 (18.3)
.96 (24.3)
1.23 (31.2)

.63 (16)
.79 (20)
.98 (25)
1.26 (32)
1.57 (40)

Ex-e
Nylon Glands

Fast installation of flexible


Polyamide Conduit
ATEX Certified Conduit
Standard applications in
hazardous locations type e

-4F to 203F
(-20C to 95C)

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Part Numbers

Conduits of the Snapflex-Ex series are based on Metric dimensions. They were
designed for standard application in hazard location type e according to
EN 60079-0 and EN 60079-7.

Ex-e Multi-Hole &


Romex Glands

Mounting Brackets - Nylon - Snapclip-Ex


Conduit System - Metric - Ex-e

ATEX

Mounting Brackets
Part Numbers
C1

-4F to 203F
(-20C to 95C)

Dimensions
A

B1

C1

Width

Length

OverallLength

Height

OverallHeight

Mounting
Hole

Mounting
Hole
Recess

16
20
25
32
40

.47 (12)
.47 (12)
.59 (15)
.63 (16)
.63 (16)

1.06 (27)
1.22 (31)
1.42 (36)
1.69 (43)
2.01 (51)

1.16 (29.5)
1.32 (33.5)
1.42 (36)
1.79 (45.5)
2.11 (53.5)

.21 (5.3)
.21 (5.3)
.21 (5.3)
.21 (5.3)
.21 (5.3)

.39 (10)
.39 (10)
.39 (10)
.39 (10)
.39 (10)

E
B
B1

MC-16-BX
MC-20-BX
MC-25-BX
MC-32-BX
MC-40-BX

Hold conduit securely in place.


Material: Black Nylon 6/6

Conduit & Strain Relief Fittings - Snapclic DUO


Nickel Plated Brass - Conduit System - Metric - Ex-e

Rotatable
Conduit

II 2G 1D
Snapclic DUO Conduit Fitting - Nickel Plated Brass
Part Numbers

Cable Range

-4F to 203F
(-20C to 95C)

SnapflexEx
A
Conduit
Size SeeHole
pageO.D.

Page 59
for Thread
Specs

49 for thread
+ .01
specs
(+.25 mm)

Dimensions
B

Thread
Length

Body
Length

Outer
Diameter

Wrench
Flat

M16 x 1.5

16

.63 (16)

.24 (6)

.984 (25)

1.52 (38.5)

.94/.79 (24/20)

M20 x 1.5

20

.79 (20)

.24 (6)

1.18 (30)

1.63 (41.5)

1.10/.94 (28/24)

M25 x 1.5

25

.98 (25)

.28 (7)

1.38 (35)

1.75 (44.5) 1.34/1.18 (34/30)

M32 x 1.5

32

1.26 (32)

.31 (8)

1.65 (42)

2.07 (52.5)

1.57 (40)

M40 x 1.5

40

1.57 (40)

.31 (8)

1.97 (50)

2.32 (59)

1.97 (50)

Ex-e Conduit &


Fitting Systems

Inches (mm)

IP 68

Ex-e / Ex-d
Accessories

DUO17MA-MX .20 - .39 (5 - 10)


DUO17MR-MX
.12 - .28 (3 - 7)
DUO22MA-MX .39 - .55 (10 - 14)
DUO22MR-MX .28 - .47 (7 - 12)
DUO25MA-MX .51 - .71 (13 - 18)
DUO25MR-MX .35 - .63 (9 - 16)
DUO32MA-MX .71 - .94 (18 - 24)
DUO32MR-MX .51 - .79 (13 - 20)
DUO40MA-MX .87 - 1.22 (22 - 31)
DUO40MR-MX .79 - 1.02 (20 - 26)

Thread
Type
& Size

IP 54

Ex-e EMI / RFI Nickel


Plated Brass Glands

ATEX

.83 (21)
.82 (27)
1.10 (28) 1.46 (37)
1.34 (34) 1.46 (37)
1.65 (42) 1.67 (42.5)
2.01 (51) 2.05 (52

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Fits
Snapflex-Ex
Conduit
Size

Also Available In PG, NPT &


Elongated Threads with EMI
protection!

Suggested Clearance
Hole for Non-Threaded
Mounting

800-456-9012

Dimensions, specifications and certifications may be changed without prior notice.

www.sealconex.com

45

Technical
Information

Protection Rating:
Threaded / Installation side - IP 68
Conduit side - IP 54

Locking Nuts
303 Stainless Steel

Page 46

Page 47

Locking Nuts
Nickel Plated Brass

Locking Nuts
Nylon (Black & Gray)

Page 48

Page 48

Hole Plugs
Mushroom Hole Plugs

Thread Reducers
Metric & PG

Hex Hole Plugs


Nylon & Nickel Plated Brass Page 49-50

Page 51-53

Seal Ring
Fiber Reinforced Nylon

Page 54

Page 54

Earth Tags
Grounding Tags

Washers
Serrated Washers

Page 54

Page 54

Shroud
Protective Sleeve

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Ex-e Multi-Hole &


Romex Glands

Ex-e
Nylon Glands

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Ex-d EXIOS
Cable Glands

Accessories for Cable Glands


Overview

Ex-e EMI / RFI Nickel


Plated Brass Glands

Locking Nuts - Accessories


(303) Stainless Steel (INOX) - Metric / PG Sizes
Locking Nuts: (303) Stainless Steel - Metric Threads
Part Numbers

Ex-e Conduit &


Fitting Systems

Page 59
for Thread
Specs

NM-12-SS
NM-16-SS
NM-20-SS
NM-25-SS
NM-32-SS
NM-40-SS
NM-50-SS
NM-63-SS

Ex-e / Ex-d
Accessories

Technical
Information

Thread
Type
& Size

M12 x 1.5
M16 x 1.5
M20 x 1.5
M25 x 1.5
M32 x 1.5
M40 x 1.5
M50 x 1.5
M63 x 1.5

Dimensions in Inches (mm)


G

Thickness

Wrench
Flats

.11 (2.8)
.11 (2.8)
.12 (3)
.14 (3.5)
.14 (3.5)
.20 (5)
.20 (5)
.24 (6)

.59 (15)
.75 (19)
.94 (24)
1.18 (30)
1.42 (36)
1.81 (46)
2.24 (57)
2.76 (70)

Typical applications for Stainless Steel:


Off-shore, Marine, Chemical Plants, Food Processing,
Clean Room, Other Rugged Applications
46

www.sealconex.com

Locking Nuts: (303) Stainless Steel - PG Threads


Part Numbers

Thread Type
& Size
Page 59
for Thread
Specs

NP-07-SS
NP-09-SS
NP-11-SS
NP-13-SS
NP-16-SS
NP-21-SS
NP-29-SS
NP-36-SS

PG 7
PG 9
PG 11
PG 13 / 13.5
PG 16
PG 21
PG 29
PG 36

(303) Stainless
Steel Locking
Nuts

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Dimensions in Inches (mm)


G

Thickness

Wrench
Flats

.11 (2.8)
.11 (2.8)
.12 (3)
.12 (3)
.12 (3)
.14 (3.5)
.16 (4)
.20 (5)

.67 (17)
.87 (22)
.87 (22)
.94 (24)
1.06 (27)
1.26 (32)
1.61 (41)
1.97 (50)

Wrench
Flat (H)

Locking Nuts: Nickel Plated Brass - NPT & Metric Threads


Thread Type
& Size
Page 59
for Thread
Specs

Nickel Plated Brass

Locking Nuts: Nickel Plated Brass - PG Threads

Dimensions in Inches (mm)


G

Thickness

Wrench
Flats

.14 (3.5)
.12 (3)
.14 (3.5)
.14 (3.5)

.75 (19)
.94 (24)
1.18 (30)
1.38 (35)

NM-12-BR
NM-16-BR
NM-20-BR
NM-25-BR
NM-32-BR
NM-40-BR
NM-50-BR
NM-63-BR
NM-75-XL

M12 x 1.5
M16 x 1.5
M20 x 1.5
M25 x 1.5
M32 x 1.5
M40 x 1.5
M50 x 1.5
M63 x 1.5
M75 x 1.5

.11 (2.8)
.11 (2.8)
.12 (3)
.14 (3.5)
.16 (4)
.18 (4.5)
.22 (5.5)
.24 (6)
.31 (8)

.59 (15)
.75 (19)
.91 (23)
1.14 (29)
1.42 (36)
1.77 (45)
2.17 (55)
2.76 (70)
3.35 (85)

Nickel Plated Brass


NP-07-BR
NP-09-BR
NP-11-BR
NP-13-BR
NP-16-BR
NP-21-BR
NP-29-BR
NP-36-BR
NP-42-BR
NP-48-BR

Wrench
Flat (H)

Thickness

Wrench
Flats

.11 (2.8)
.11 (2.8)
.12 (3)
.12 (3)
.12 (3)
.14 (3.5)
.16 (4)
.20 (5)
.20 (5)
.22 (5.5)

.59 (15)
.71 (18)
.83 (21)
.91 (23)
1.02 (26)
1.26 (32)
1.61 (41)
2.01 (51)
2.36 (60)
2.52 (64)

Thread
Type
& Size

Dimensions in Inches (mm)


H

Thickness

Wrench Flats

Zinc Plated Steel

Page 59
for Thread
Specs

NN-10-ST
NN-34-ST
NN-36-ST

1 NPT
1-1/4 NPT
1-1/2 NPT

.24 (6)
.20 (5)
.16 (4)

1.73 (44)
2.01 (53)
2.19 (55.5)

Ex-e Nickel Plated Brass &


Stainless Steel Glands

(-ST)
Zinc Plated
Steel Locking
Nuts

Wrench
Flat (H)

PG 7
PG 9
PG 11
PG 13 / 13.5
PG 16
PG 21
PG 29
PG 36
PG 42
PG 48

Locking Nuts: Zinc Plated Steel - NPT Threads


Part Numbers

(-BR)
Nickel Plated
Brass Locking
Nuts

Page 59
for Thread
Specs

Dimensions in Inches (mm)

Ex-e Multi-Hole &


Romex Glands

3/8 NPT
1/2 NPT
3/4 NPT
1 NPT

Thread
Type
& Size

Ex-e
Nylon Glands

NN-09-BR
NN-13-BR
NN-21-BR
NN-29-BR

Part Numbers

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Part Numbers

Ex-d EXIOS
Cable Glands

Locking Nuts - Accessories


Nickel Plated Brass/Zinc Plated Steel - NPT/Metric/PG

EMI/RFI Locking Nuts - Accessories


Nickel Plated Brass - Metric / PG Sizes

Part Numbers

Thread Type
& Size
Page 59
for Thread
Specs

Locking Nuts: (EMI/RFI) Nickel Plated Brass


PG Threads

Dimensions in Inches (mm)


G

Thickness

Wrench
Flats

.12 (3)

.94 (24)

NM-12-BE
NM-16-BE
NM-20-BE
NM-25-BE
NM-32-BE
NM-40-BE
NM-50-BE
NM-63-BE

M12 x 1.5
M16 x 1.5
M20 x 1.5
M25 x 1.5
M32 x 1.5
M40 x 1.5
M50 x 1.5
M63 x 1.5

.11 (2.8)
.11 (2.8)
.12 (3)
.14 (3.5)
.18 (4.5)
.20 (5)
.20 (5)
.24 (6)

.59 (15)
.75 (19)
.94 (24)
1.18 (30)
1.42 (36)
1.81 (46)
2.36 (60)
2.76 (70)

EMI/RFI Proof
Locking Nuts

Page 59
for Thread
Specs

NP-07-BE
NP-09-BE
NP-11-BE
NP-13-BE
NP-16-BE
NP-21-BE
NP-29-BE
NP-36-BE
NP-42-BE
NP-48-BE

PG 7
PG 9
PG 11
PG 13 / 13.5
PG 16
PG 21
PG 29
PG 36
PG 42
PG 48

Dimensions in Inches (mm)


G

Thickness

Wrench
Flats

.11 (2.8)
.11 (2.8)
.12 (3)
.12 (3)
.12 (3)
.14 (3.5)
.16 (4)
.20 (5)
.20 (5)
.22 (5.5)

.59 (15)
.71 (18)
.83 (21)
.91 (23)
1.02 (26)
1.26 (32)
1.61 (41)
2.01 (51)
2.36 (60)
2.52 (64)

Ex-e / Ex-d
Accessories

1/2 NPT

Thread
Type
& Size

Ex-e Conduit &


Fitting Systems

NN-13-BE

Part Numbers

Ex-e EMI / RFI Nickel


Plated Brass Glands

Locking Nuts: (EMI/RFI) Nickel Plated Brass


NPT & Metric Threads

These Locking Nuts have cutting edges which slice


through paint coatings on metal enclosures to ensure
grounding. Ideal in vibrating installations too.

800-456-9012

Wrench Flat (H)

Dimensions, specifications and certifications may be changed without prior notice.

www.sealconex.com

47

Technical
Information

Ex-d EXIOS
Cable Glands

Locking Nuts - Accessories


Nylon - NPT / Metric / PG Sizes
Locking Nuts: Nylon Black & Gray, V0 Rated UL 94

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Part Numbers

Black

Gray

Thickness

Wrench Flats

Ex-e
Nylon Glands

Ex-e Multi-Hole &


Romex Glands

Ex-e Nickel Plated Brass &


Stainless Steel Glands

NN-09-BK
NN-13-BK
NN-21-BK
NN-29-BK

NN-09-GY
NN-13-GY
NN-21-GY
NN-29-GY

3/8 NPT
1/2 NPT
3/4 NPT
1 NPT

.28 (7)
.24 (6)
.28 (7)
.28 (7)

.94 (24)
1.06 (27)
1.26 (32)
1.57 (40)

NM-12-BK
NM-16-BK
NM-20-BK
NM-25-BK
NM-32-BK
NM-40-BK
NM-50-BK
NM-63-BK

NM-12-GY
NM-16-GY
NM-20-GY
NM-25-GY
NM-32-GY
NM-40-GY
NM-50-GY
NM-63-GY

M12 x 1.5
M16 x 1.5
M20 x 1.5
M25 x 1.5
M32 x 1.5
M40 x 1.5
M50 x 1.5
M63 x 1.5

.20 (5)
.20 (5)
.24 (6)
.26 (6.5)
.28 (7)
.28 (7)
.31 (8)
.31 (8)

.67 (17)
.87 (22)
1.06 (27)
1.26 (32)
1.61 (41)
1.97 (50)
2.36 (60)
2.95 (75)

NP-07-BK
NP-09-BK
NP-11-BK
NP-13-BK
NP-16-BK
NP-21-BK
NP-29-BK
NP-36-BK
NP-42-BK
NP-48-BK

NP-07-GY
NP-09-GY
NP-11-GY
NP-13-GY
NP-16-GY
NP-21-GY
NP-29-GY
NP-36-GY
NP-42-GY
NP-48-GY

PG 7
PG 9
PG 11
PG 13 / 13.5
PG 16
PG 21
PG 29
PG 36
PG 42
PG 48

.20 (5)
.20 (5)
.20 (5)
.24 (6)
.24 (6)
.28 (7)
.28 (7)
.31 (8)
.31 (8)
.31 (8)

.75 (19)
.87 (22)
.94 (24)
1.06 (27)
1.18 (30)
1.41 (36)
1.81 (46)
2.36 (60)
2.56 (65)
2.76 (70)

ATEX

Nylon Locking Nuts

II 2G 1D

Wrench
Flat (H)

Mushroom Hole Plugs - Accessories


Elastomer - NPT / Metric / PG - ATEX / IECEx / Ex-e
Hole Plugs: Mushroom - NPT/Metric & PG Threads

Part Numbers

Thread
Type
& Size

-4F to 203F
(-20C to 95C)

Ex-e Conduit &


Fitting Systems

Ex-e EMI / RFI Nickel


Plated Brass Glands

-40F to 212F
(-40C to 100C)

Dimensions in Inches (mm)

Page 59
for Thread
Specs

Ex-e / Ex-d
Accessories

Technical
Information

-40F to 212F
(-40C to 100C)

Thread
Type
& Size

(Mushroom Plug)

Page 59
for Thread
Specs

PV-07-BX
PV-09-BX
PV-11-BX
PV-13-BX
PV-16-BX
PV-21-BX
PV-29-BX
PV-36-BX
PV-42-BX
PV-48-BX

PG 7 / M12 x 1,5
PG 9 / M16 x 1.5 / 3/8 NPT
PG 11 / M16-E
PG 13 / M20 x 1.5 / 1/2 NPT
PG 16 / 1/2 NPT-E / M20-E
PG 21 / M25 x 1.5 / 3/4 NPT
PG 29 / M32 x 1.5 / 1 NPT / 1 1/4 NPT
PG 36 / M40 x 1.5 / 1 1/4 NPT
PG 42 / M50 x 1.5
PG 48 / M63 x 1.5

Dimensions in Inches (mm)


A

Plug
Diameter

Dome
Height

Overall
Height

Dome
Width
A

.25 (6.3)
.31 (7.8)
.39 (9.8)
.46 (11.8)
.54 (13.8)
.70 (17.8)
.98 (25)
1.26 (32)
1.50 (38)
1.73 (44)

.18 (4.5)
.22 (5.5)
.22 (5.5)
.32 (8)
.35 (9)
.43 (11)
.39 (10)
.43 (11)
.47 (12)
.47 (12)

.45 (11.5)
.53 (13.5)
.57 (14.5)
.71 (18)
.75 (19)
.87 (22)
.98 (25)
1.10 (28)
1.18 (30)
1.18 (30)

.37 (9.5)
.43 (11)
.53 (13.5)
.63 (16)
.73 (18.5)
.87 (22)
1.14 (29)
1.50 (38)
1.69 (43)
1.93 (49)

* Note: Mushroom Plugs should only be used in cable glands with standard inserts.

48

www.sealconex.com

D
H

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

II 2G 1D

Hex Plugs - Accessories - Nylon / Nickel Plated


Brass - Metric / PG - ATEX / IECEx / Ex-e

Ex-d EXIOS
Cable Glands

ATEX

Hex Plugs: Nylon w/ Buna-N O-Ring - Metric & PG Threads, IP 68/69K, 150 PSIG, 10 BAR
-4F to 194F
(-20C to 90C)

Thread
Type
& Size
Page 59
for Thread
Specs

Dimensions in Inches (mm)


H

Overall
Height

Overall
Width

Thread
Length

Wrench
Flat

Allen
Wrench
Size

.65 (16.5)
.81 (20.5)
1.00 (25.5)
1.20 (30.5)
1.50 (38)
1.89 (48)
2.36 (60)
2.95 (75)

.33 (8.5)
.33 (8.5)
.35 (9)
.41 (10.5)
.45 (11.5)
.45 (11.5)
.53 (13.5)
.57 (14.5)

.59 (15)
.75 (19)
.94 (24)
1.10 (28)
1.42 (36)
1.81 (46)
2.17 (55)
2.76 (70)

.24 (6)
.31 (8)
.31 (8)
.31 (8)
.31 (8)
.31 (8)
.31 (8)
.31 (8)

HP-07-BX
HP-09-BX
HP-11-BX
HP-13-BX
HP-16-BX
HP-21-BX
HP-29-BX
HP-36-BX
HP-42-BX
HP-48-BX

PG 7
PG 9
PG 11
PG 13 / 13.5
PG 16
PG 21
PG 29
PG 36
PG 42
PG 48

.51 (13)
.51 (13)
.57 (14.5)
.57 (14.5)
.63 (16)
.69 (17.5)
.71 (18)
.79 (20)
.79 (20)
.83 (21)

.65 (16.5)
.81 (20.5)
1.00 (25.5)
1.00 (25.5)
1.20 (30.5)
1.50 (38)
1.89 (48)
2.36 (60)
2.56 (65)
2.95 (75)

.33 (8.5)
.33 (8.5)
.35 (9)
.35 (9)
.41 (10.5)
.45 (11.5)
.45 (11.5)
.53 (13.5)
.53 (13.5)
.57 (14.5)

.59 (15)
.75 (19)
.94 (24)
.94 (24)
1.10 (28)
1.42 (36)
1.81 (46)
2.17 (55)
2.36 (60)
2.76 (70)

.24 (6)
.31 (8)
.31 (8)
.31 (8)
.31 (8)
.31 (8)
.31 (8)
.31 (8)
.31 (8)
.31 (8)

Nylon Hex Plug


X
D

H
T

THREAD TYPE

Note: HP & HM Nylon Plugs can be


tightened with Hex & Allen wrenches,
as well as regular screwdrivers.

Nickel Plated Brass


Hex Plug

Ex-e Nickel Plated Brass &


Stainless Steel Glands

.51 (13)
.51 (13)
.57 (14.5)
.63 (16)
.69 (17.5)
.71 (18)
.79 (20)
.83 (21)

*CE applies to all Nickel Plated Brass Hex Plugs only!


H
T
THREAD TYPE

Hex Plugs: Nickel Plated Brass - Metric & PG Threads , IP 68/69K, 150 PSIG, 10 BAR
Part Numbers
-4F to 203F
(-20C to 95C)

-4F to 356F
(-20C to 180C)

-76F to 356F
(-60C to 180C)

Thread
Type
& Size

Dimensions in Inches (mm)


T

Overall
Height

Thread
Length

Wrench
Flat

Page 59
for Thread
Specs

M12 x 1.5
M16 x 1.5
M20 x 1.5
M25 x 1.5
M32 x 1.5
M40 x 1.5
M50 x 1.5
M63 x 1.5

.37 (9.5)
.35 (9)
.37 (9.5)
.41 (10.5)
.49 (12.5)
.51 (13)
.59 (15)
.65 (16.5)

.26 (6.5)
.24 (6)
.24 (6)
.28 (7)
.31 (8)
.31 (8)
.35 (9)
.39 (10)

.55 (14)
.75 (19)
.87 (22)
1.18 (30)
1.61 (41)
1.81 (46)
2.17 (55)
2.76 (70)

HP-07-MX
HP-09-MX
HP-11-MX
HP-13-MX
HP-16-MX
HP-21-MX
HP-29-MX
HP-36-MX
HP-42-MX
HP-48-MX

HP-07-MX-V
HP-09-MX-V
HP-11-MX-V
HP-13-MX-V
HP-16-MX-V
HP-21-MX-V
HP-29-MX-V
HP-36-MX-V
HP-42-MX-V
HP-48-MX-V

HP-07-MX-S
HP-09-MX-S
HP-11-MX-S
HP-13-MX-S
HP-16-MX-S
HP-21-MX-S
HP-29-MX-S
HP-36-MX-S
HP-42-MX-S
HP-48-MX-S

PG 7
PG 9
PG 11
PG 13.5
PG 16
PG 21
PG 29
PG 36
PG 42
PG 48

.31 (8)
.35 (9)
.37 (9.5)
.39 (10)
.39 (10)
.41 (10.5)
.49 (12.5)
.51 (13)
.59 (15)
.65 (16.5)

.20 (5)
.24 (6)
.24 (6)
.26 (6.5)
.26 (6.5)
.28 (7)
.31 (8)
.31 (8)
.35 (9)
.39 (10)

.55 (14)
.67 (17)
.79 (20)
.87 (22)
.94 (24)
1.18 (30)
1.61 (41)
1.97 (50)
2.28 (58)
2.56 (65)

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

When extra approvals


are required, use the part
numbers on page 50!
Part Numbers
HM-xx-MX-D
HM-xx-MVX-D
HM-xx-MIX-D

O-Rings
Buna-N
FPM
Silicone

www.sealconex.com

49

Technical
Information

Silicone
HM-12-MX-S
HM-16-MX-S
HM-20-MX-S
HM-25-MX-S
HM-32-MX-S
HM-40-MX-S
HM-50-MX-S
HM-63-MX-S

Ex-e / Ex-d
Accessories

FPM
HM-12-MX-V
HM-16-MX-V
HM-20-MX-V
HM-25-MX-V
HM-32-MX-V
HM-40-MX-V
HM-50-MX-V
HM-63-MX-V

Nickel Plated Brass


Hex Plug in Metric
Threads Ex-d versions.

Ex-e Conduit &


Fitting Systems

Buna-N
HM-12-MX
HM-16-MX
HM-20-MX
HM-25-MX
HM-32-MX
HM-40-MX
HM-50-MX
HM-63-MX

Also Available:

Ex-e EMI / RFI Nickel


Plated Brass Glands

Ex-e Multi-Hole &


Romex Glands

M12 x 1.5
M16 x 1.5
M20 x 1.5
M25 x 1.5
M32 x 1.5
M40 x 1.5
M50 x 1.5
M63 x 1.5

Ex-e
Nylon Glands

Black Nylon
HM-12-BX
HM-16-BX
HM-20-BX
HM-25-BX
HM-32-BX
HM-40-BX
HM-50-BX
HM-63-BX

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Part Numbers

Part Numbers
-4F to 203F
(-20C to 95C)

-4F to 356F
(-20C to 180C)

Thread
Type
& Size

-78F to 356F
(-60C to 180C)

Dimensions in Inches (mm)

Ex-e
Nylon Glands

-60C

Ex-e Multi-Hole &


Romex Glands

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Ex-e EMI / RFI Nickel


Plated Brass Glands

Ex-e Conduit &


Fitting Systems

Ex-e / Ex-d
Accessories

Technical
Information

Hex Plugs - Accessories


(303) Stainless Steel - Metric / PG - Ex-e

II 2G 1D

Hex Plugs: (303) Stainless Steel Ex-e - Metric & PG Threads, IP 68/69K, NEMA 6, 150 PSIG, 10 BAR

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Ex-d EXIOS
Cable Glands

ATEX

Page 59
for Thread
Specs

Silicone version
accommodates
-60C

Overall
Height

Thread
Length

Wrench
Flat

Temperature

Buna-N
HM-12-SX
HM-16-SX
HM-20-SX
HM-25-SX
HM-32-SX
HM-40-SX
HM-50-SX
HM-63-SX

FPM
HM-12-SX-V
HM-16-SX-V
HM-20-SX-V
HM-25-SX-V
HM-32-SX-V
HM-40-SX-V
HM-50-SX-V
HM-63-SX-V

Silicone
HM-12-SX-S
HM-16-SX-S
HM-20-SX-S
HM-25-SX-S
HM-32-SX-S
HM-40-SX-S
HM-50-SX-S
HM-63-SX-S

M12 x 1.5
M16 x 1.5
M20 x 1.5
M25 x 1.5
M32 x 1.5
M40 x 1.5
M50 x 1.5
M63 x 1.5

.37 (9.5)
.35 (9)
.37 (9.5)
.41 (10.5)
.49 (12.5)
.51 (13)
.59 (15)
.65 (16.5)

.26 (6.5)
.24 (6)
.24 (6)
.28 (7)
.31 (8)
.31 (8)
.35 (9)
.39 (10)

.55 (14)
.75 (19)
.87 (22)
1.18 (30)
1.61 (41)
1.81 (46)
2.17 (55)
2.76 (70)

HP-07-SX
HP-09-SX
HP-11-SX
HP-13-SX
HP-16-SX
HP-21-SX
HP-29-SX
HP-36-SX
HP-42-SX
HP-48-SX

HP-07-SX-V
HP-09-SX-V
HP-11-SX-V
HP-13-SX-V
HP-16-SX-V
HP-21-SX-V
HP-29-SX-V
HP-36-SX-V
HP-42-SX-V
HP-48-SX-V

HP-07-SX-S
HP-09-SX-S
HP-11-SX-S
HP-13-SX-S
HP-16-SX-S
HP-21-SX-S
HP-29-SX-S
HP-36-SX-S
HP-42-SX-S
HP-48-SX-S

PG 7
PG 9
PG 11
PG 13.5
PG 16
PG 21
PG 29
PG 36
PG 42
PG 48

.31 (8)
.35 (9)
.37 (9.5)
.39 (10)
.39 (10)
.41 (10.5)
.49 (12.5)
.51 (13)
.59 (15)
.65 (16.5)

.20 (5)
.24 (6)
.24 (6)
.26 (6.5)
.26 (6.5)
.28 (7)
.31 (8)
.31 (8)
.35 (9)
.39 (10)

.55 (14)
.67 (17)
.79 (20)
.87 (22)
.94 (24)
1.18 (30)
1.61 (41)
1.97 (50)
2.28 (58)
2.56 (65)

ATEX

AISI 303 Stainless


Steel Hex Plugs

Hex Plugs - Accessories - Nickel Plated Brass &


(316L) Stainless Steel - NPT / Metric - Ex-d/Ex-e

II 2G 1D
Ex d IIC

Hex Plugs: Nickel Plated Brass & (316L) Stainless Steel Ex-d/Ex-e - Metric Threads, IP 68/69K, NEMA 6, 150 PSIG, 10 BAR
Part Numbers - Nickel Plated Brass *
-4F to 203F
(-20C to 95C)

-4F to 356F
-76F to 356F
(-20C to 180C) (-60C to 180C)

Part Numbers - Stainless Steel **


-4F to 203F
(-20C to 95C)

-4F to 356F
-76F to 356F
(-20C to 180C) (-60C to 180C)

-60C

-60C

Buna-N
HN-38-MX-D*
HN-12-MX-D*
HN-34-MX-D*
HN-10-MX-D*
HN-54-MX-D*
HN-64-MX-D*

Viton

HM-12-MX-D
HM-16-MX-D
HM-20-MX-D
HM-25-MX-D
HM-32-MX-D
HM-40-MX-D
HM-50-MX-D
HM-63-MX-D

HM-12-MVX-D
HM-16-MVX-D
HM-20-MVX-D
HM-25-MVX-D
HM-32-MVX-D
HM-40-MVX-D
HM-50-MVX-D
HM-63-MVX-D

Silicone

HM-12-MIX-D
HM-16-MIX-D
HM-20-MIX-D
HM-25-MIX-D
HM-32-MIX-D
HM-40-MIX-D
HM-50-MIX-D
HM-63-MIX-D

Thread
Type
& Size

Buna-N
HN-38-6X-D*
HN-12-6X-D*
HN-34-6X-D*
HN-10-6X-D*
HN-54-6X-D*
HN-64-6X-D*

Viton

HM-12-6X-D
HM-16-6X-D
HM-20-6X-D
HM-25-6X-D
HM-32-6X-D
HM-40-6X-D
HM-50-6X-D
HM-63-6X-D

HM-12-6VX-D
HM-16-6VX-D
HM-20-6VX-D
HM-25-6VX-D
HM-32-6VX-D
HM-40-6VX-D
HM-50-6VX-D
HM-63-6VX-D

Page 59
for Thread
Specs

Silicone

Dimensions in Inches (mm)


H

Overall
Height

Overall
Height

Thread
Length

Wrench
Flat

(Nickel
Plated
Brass)

(Stainless
Steel)

NPT 3/8 .79 (20) .79 (20) .63 (16) *.63 (16) & **.75 (19)
NPT 1/2 .93 (23.5) .93 (23.5) .79 (20)
.75 (24)
NPT 3/4 .94 (24) .94 (24) .81 (20.5)
1.18 (30)
NPT 1 1.16 (29.5) 1.16 (29.5) .98 (25)
1.61 (41)
NPT 1 1/4 1.22 (31) 1.22 (31) 1.02 (26)
1.81 (46)
NPT 1 1/2 1.27 (32.5) 1.27 (32.5) 1.04 (26.5)
2.17 (55)
HM-12-6IX-D
HM-16-6IX-D
HM-20-6IX-D
HM-25-6IX-D
HM-32-6IX-D
HM-40-6IX-D
HM-50-6IX-D
HM-63-6IX-D

M12 x 1.5
M16 x 1.5
M20 x 1.5
M25 x 1.5
M32 x 1.5
M40 x 1.5
M50 x 1.5
M63 x 1.5

.67 (17)
.63 (16)
.61 (15.5)
.61 (15.5)
.65 (16.5)
.67 (17)
.71 (18)
.73 (18.5)
X

*All NPT Hex Plugs do not


come with an O-Ring.

AISI (316L) Stainless


Steel Hex Plugs

H
T

.75 (19)
.75 (19)
.77 (19.5)
.77 (19.5)
. 81 (20.5)
.83 (21)
.87 (22)
.89 (22.5)

Silicone version
accommodates
-60C

THREAD TYPE

50

www.sealconex.com

.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Temperature

.55 (14)
.75 (19)
.87 (22)
1.18 (30)
1.61 (41)
1.81 (46)
2.17 (55)
2.76 (70)

Thread Reducers - Accessories


Nickel Plated Brass - Metric / PG - Ex-e

II 2G 1D

Ex-d EXIOS
Cable Glands

ATEX

Part Numbers
-4F to 203F
(-20C to 95C)

Thread Type & Size

-76F to 356F
(-60C to 180C)

-60C

Male
Thread
A

Female
Thread
B

Page 59
for Thread
Specs

Page 59
for Thread
Specs

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Thread Reducers: Nickel Plated Brass - Metric & PG Threads, IP 68/69K, 150 PSIG, 10 BAR
Dimensions in Inches (mm)
H

Overall
Height

Thread
Length

Wrench
Flat

.20 (5)
.24 (6)
.24 (6)
.28 (7)
.28 (7)
.31 (8)
.31 (8)
.31 (8)
.31 (8)
.31 (8)
.31 (8)
.35 (9)
.35 (9)
.35 (9)
.39 (10)
.39 (10)
.39 (10)

.67 (17)
.87 (22)
.87 (22)
1.14 (29)
1.14 (29)
1.34 (34)
1.34 (34)
1.34 (34)
1.69 (43)
1.69 (43)
1.69 (43)
2.17 (55)
2.17 (55)
2.17 (55)
2.56 (65)
2.56 (65)
2.56 (65)

RQ-0907-MX
RQ-1107-MX
RQ-1109-MX
RQ-1309-MX
RQ-1609-MX
RQ-1611-MX
RQ-1613-MX
RQ-2111-MX
RQ-2113-MX
RQ-2116-MX
RQ-2916-MX
RQ-2921-MX
RQ-3621-MX
RQ-3629-MX
RQ-4229-MX
RQ-4236-MX
RQ-4836-MX
RQ-4842-MX

RQ-0907-MX-S
RQ-1107-MX-S
RQ-1109-MX-S
RQ-1309-MX-S
RQ-1609-MX-S
RQ-1611-MX-S
RQ-1613-MX-S
RQ-2111-MX-S
RQ-2113-MX-S
RQ-2116-MX-S
RQ-2916-MX-S
RQ-2921-MX-S
RQ-3621-MX-S
RQ-3629-MX-S
RQ-4229-MX-S
RQ-4236-MX-S
RQ-4836-MX-S
RQ-4842-MX-S

PG 9
PG 11
PG 11
PG13
PG 16
PG 16
PG 16
PG 21
PG 21
PG 21
PG 29
PG 29
PG 36
PG 36
PG 42
PG 42
PG 48
PG 48

PG 7
PG 7
PG 9
PG 9
PG 9
PG 11
PG 13
PG 11
PG 13
PG 16
PG 16
PG 21
PG 21
PG 29
PG 29
PG 36
PG 36
PG 42

.35 (8.8)
.35 (9)
.35 (9)
.37 (9.5)
.37 (9.5)
.37 (9.5)
.37 (9.5)
.41 (10.3)
.41 (10.3)
.41 (10.3)
.45 (11.5)
.45 (11.5)
.49 (12.5)
.49 (12.5)
.53 (13.5)
.53 (13.5)
.53 (13.5)
.53 (13.5)

.24 (6)
.24 (6)
.24 (6)
.26 (6.5)
.26 (6.5)
.26 (6.5)
.26 (6.5)
.28 (7)
.28 (7)
.28 (7)
.31 (8)
.31 (8)
.35 (9)
.35 (9)
.39 (10)
.39 (10)
.39 (10)
.39 (10)

.67 (17)
.79 (20)
.79 (20)
.87 (22)
.94 (24)
.94 (24)
.94 (24)
1.18 (30)
1.18 (30)
1.18 (30)
1.57 (40)
1.57 (40)
1.97 (50)
1.97 (50)
2.24 (57)
2.24 (57)
2.52 (64)
2.52 (64)

Ex-e Conduit &


Fitting Systems

.31 (8)
.35 (9)
.35 (9)
.39 (10)
.39 (10)
.43 (11)
.43 (11)
.43 (11)
.47 (12)
.47 (12)
.47 (12)
.51 (13)
.51 (13)
.51 (13)
.55 (14)
.55 (14)
.55 (14)

Ex-e EMI / RFI Nickel


Plated Brass Glands

M12 x 1.5
M12 x 1.5
M16 x 1.5
M16 x 1.5
M20 x 1.5
M16 x 1.5
M20 x 1.5
M25 x 1.5
M20 x 1.5
M25 x 1.5
M32 x 1.5
M25 x 1.5
M32 x 1.5
M40 x 1.5
M32 x 1.5
M40 x 1.5
M50 x 1.5

Ex-e Nickel Plated Brass &


Stainless Steel Glands

M16 x 1.5
M20 x 1.5
M20 x 1.5
M25 x 1.5
M25 x 1.5
M32 x 1.5
M32 x 1.5
M32 x 1.5
M40 x 1.5
M40 x 1.5
M40 x 1.5
M50 x 1.5
M50 x 1.5
M50 x 1.5
M63 x 1.5
M63 x 1.5
M63 x 1.5

Ex-e Multi-Hole &


Romex Glands

w/ Silicone O-Ring
RM-1612-MX-S
RM-2012-MX-S
RM-2016-MX-S
RM-2516-MX-S
RM-2520-MX-S
RM-3216-MX-S
RM-3220-MX-S
RM-3225-MX-S
RM-4020-MX-S
RM-4025-MX-S
RM-4032-MX-S
RM-5025-MX-S
RM-5032-MX-S
RM-5040-MX-S
RM-6332-MX-S
RM-6340-MX-S
RM-6350-MX-S

Ex-e
Nylon Glands

w/ Buna-N O-Ring
RM-1612-MX
RM-2012-MX
RM-2016-MX
RM-2516-MX
RM-2520-MX
RM-3216-MX
RM-3220-MX
RM-3225-MX
RM-4020-MX
RM-4025-MX
RM-4032-MX
RM-5025-MX
RM-5032-MX
RM-5040-MX
RM-6332-MX
RM-6340-MX
RM-6350-MX

X
H
T
THREAD TYPE

Silicone version
accommodates
-60C
Temperature

www.sealconex.com

51

Technical
Information

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Ex-e / Ex-d
Accessories

NPT Threads &


Additonal Sizes
Available Upon
Request!

Thread Reducers - Accessories


(303) Stainless Steel - Metric / PG - Ex-e

II 2G 1D

Thread Reducers: (303) Stainless Steel - Metric & PG Threads, IP 68/69K, 150 PSIG, 10 BAR

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Ex-d EXIOS
Cable Glands

ATEX

Part Numbers
-4F to 203F
(-20C to 95C)

Thread Type & Size

-76F to 356F
(-60C to 180C)

Ex-e Conduit &


Fitting Systems

Ex-e EMI / RFI Nickel


Plated Brass Glands

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Ex-e Multi-Hole &


Romex Glands

Ex-e
Nylon Glands

-60C

Male
Thread
A

Female
Thread
B

Page 59
for Thread
Specs

Page 59
for Thread
Specs

Dimensions in Inches (mm)


H

Overall
Height

Thread
Length

Wrench
Flat

w/ Buna-N O-Ring
RM-1612-SX
RM-2012-SX
RM-2016-SX
RM-2516-SX
RM-2520-SX
RM-3216-SX
RM-3220-SX
RM-3225-SX
RM-4020-SX
RM-4025-SX
RM-4032-SX
RM-5025-SX
RM-5032-SX
RM-5040-SX
RM-6332-SX
RM-6340-SX
RM-6350-SX

w/ Silicone O-Ring
RM-1612-SX-S
RM-2012-SX-S
RM-2016-SX-S
RM-2516-SX-S
RM-2520-SX-S
RM-3216-SX-S
RM-3220-SX-S
RM-3225-SX-S
RM-4020-SX-S
RM-4025-SX-S
RM-4032-SX-S
RM-5025-SX-S
RM-5032-SX-S
RM-5040-SX-S
RM-6332-SX-S
RM-6340-SX-S
RM-6350-SX-S

M16 x 1.5
M20 x 1.5
M20 x 1.5
M25 x 1.5
M25 x 1.5
M32 x 1.5
M32 x 1.5
M32 x 1.5
M40 x 1.5
M40 x 1.5
M40 x 1.5
M50 x 1.5
M50 x 1.5
M50 x 1.5
M63 x 1.5
M63 x 1.5
M63 x 1.5

M12 x 1.5
M12 x 1.5
M16 x 1.5
M16 x 1.5
M20 x 1.5
M16 x 1.5
M20 x 1.5
M25 x 1.5
M20 x 1.5
M25 x 1.5
M32 x 1.5
M25 x 1.5
M32 x 1.5
M40 x 1.5
M32 x 1.5
M40 x 1.5
M50 x 1.5

.35 (9)
.37 (9.5)
.37 (9.5)
.41 (10.5)
.41 (10.5)
.49 (12.5)
.49 (12.5)
.49 (12.5)
.51 (13)
.51 (13)
.51 (13)
.59 (15)
.59 (15)
.59 (15)
.65 (16.5)
.65 (16.5)
.65 (16.5)

.20 (5)
.24 (6)
.24 (6)
.28 (7)
.28 (7)
.31 (8)
.31 (8)
.31 (8)
.31 (8)
.31 (8)
.31 (8)
.35 (9)
.35 (9)
.35 (9)
.39 (10)
.39 (10)
.39 (10)

.67 (17)
.87 (22)
.87 (22)
1.06 (27)
1.06 (27)
1.34 (34)
1.34 (34)
1.34 (34)
1.69 (43)
1.69 (43)
1.69 (43)
2.17 (55)
2.17 (55)
2.17 (55)
2.56 (65)
2.56 (65)
2.56 (65)

RQ-0907-SX
RQ-1107-SX
RQ-1109-SX
RQ-1309-SX
RQ-1309-SX
RQ-1609-SX
RQ-1611-SX
RQ-1613-SX
RQ-2111-SX
RQ-2113-SX
RQ-2116-SX
RQ-2916-SX
RQ-2921-SX
RQ-3621-SX
RQ-3629-SX
RQ-4229-SX
RQ-4236-SX
RQ-4836-SX
RQ-4842-SX

RQ-0907-SX-S
RQ-1107-SX-S
RQ-1109-SX-S
RQ-1309-SX-S
RQ-1309-SX-S
RQ-1609-SX-S
RQ-1611-SX-S
RQ-1613-SX-S
RQ-2111-SX-S
RQ-2113-SX-S
RQ-2116-SX-S
RQ-2916-SX-S
RQ-2921-SX-S
RQ-3621-SX-S
RQ-3629-SX-S
RQ-4229-SX-S
RQ-4236-SX-S
RQ-4836-SX-S
RQ-4842-SX-S

PG 9
PG 11
PG 11
PG13
PG13
PG 16
PG 16
PG 16
PG 21
PG 21
PG 21
PG 29
PG 29
PG 36
PG 36
PG 42
PG 42
PG 48
PG 48

PG 7
PG 7
PG 9
PG 9
PG 11
PG 9
PG 11
PG 13
PG 11
PG 13
PG 16
PG 16
PG 21
PG 21
PG 29
PG 29
PG 36
PG 36
PG 42

.35 (8.8)
.35 (9)
.35 (9)
.37 (9.5)
.37 (9.5)
.37 (9.5)
.37 (9.5)
.37 (9.5)
.41 (10.3)
.41 (10.3)
.41 (10.3)
.45 (11.5)
.45 (11.5)
.49 (12.5)
.49 (12.5)
.53 (13.5)
.53 (13.5)
.53 (13.5)
.53 (13.5)

.24 (6)
.24 (6)
.24 (6)
.26 (6.5)
.26 (6.5)
.26 (6.5)
.26 (6.5)
.26 (6.5)
.28 (7)
.28 (7)
.28 (7)
.31 (8)
.31 (8)
.35 (9)
.35 (9)
.39 (10)
.39 (10)
.39 (10)
.39 (10)

.67 (17)
.79 (20)
.79 (20)
.87 (22)
.87 (22)
.94 (24)
.94 (24)
.94 (24)
1.18 (30)
1.18 (30)
1.18 (30)
1.57 (40)
1.57 (40)
1.97 (50)
1.97 (50)
2.24 (57)
2.24 (57)
2.52 (64)
2.52 (64)

Silicone version
accommodates
-60C
AISI (303) Stainless
Steel Thread Reducers

Technical
Information

Ex-e / Ex-d
Accessories

Temperature

H
T
THREAD TYPE

52

www.sealconex.com

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Thread Reducers - Accessories


Nickel Plated Brass - Metric Threads - Ex-d/Ex-e

II 2G 1D
Ex d IIC

Part Numbers

Thread Type & Size

-76F to 356F
(-60C to 180C)

-60C

Page 59
for Thread
Specs

Page 59
for Thread
Specs

M16 x 1.5
M20 x 1.5
M20 x 1.5
M25 x 1.5
M25 x 1.5
M32 x 1.5
M32 x 1.5
M32 x 1.5
M40 x 1.5
M40 x 1.5
M40 x 1.5

M12 x 1.5
M12 x 1.5
M16 x 1.5
M16 x 1.5
M20 x 1.5
M16 x 1.5
M20 x 1.5
M25 x 1.5
M20 x 1.5
M25 x 1.5
M32 x 1.5

Dimensions in Inches (mm)


H

Temperature

Overall
Height

Thread
Length

Wrench
Flat

H
T
THREAD TYPE

.75 (19)
.77 (19.5)
.77 (19.5)
.77 (19.5)
.77 (19.5)
.81 (20.5)
.81 (20.5)
.81 (20.5)
.83 (21)
.83 (21)
.83 (21)

.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)

.75 (19)
.87 (22)
.87 (22)
1.18 (30)
1.18 (30)
1.61 (41)
1.61 (41)
1.61 (41)
1.81 (46)
1.81 (46)
1.81 (46)

Ex-e Multi-Hole &


Romex Glands

Thread Reducer - Accessories


(316L) Stainless Steel - Metric - Ex-d/Ex-e

II 2G 1D
Ex d IIC

Thread Reducers: (316L) Stainless Steel (INOX) Ex-d /Ex-e - Metric Threads
Part Numbers
-4F to 203F
(-20C to 95C)

Thread Type & Size

-76F to 356F
(-60C to 180C)

-60C

Page 59
for Thread
Specs

Page 59
for Thread
Specs

M16 x 1.5
M20 x 1.5
M20 x 1.5
M25 x 1.5
M25 x 1.5
M32 x 1.5
M32 x 1.5
M32 x 1.5
M40 x 1.5
M40 x 1.5
M40 x 1.5

M12 x 1.5
M12 x 1.5
M16 x 1.5
M16 x 1.5
M20 x 1.5
M16 x 1.5
M20 x 1.5
M25 x 1.5
M20 x 1.5
M25 x 1.5
M32 x 1.5

Dimensions in Inches (mm)


H

Overall
Height

Thread
Length

Wrench
Flat

Temperature
X

H
T

.75 (19)
.77 (19.5)
.77 (19.5)
.77 (19.5)
.77 (19.5)
.81 (20.5)
.81 (20.5)
.81 (20.5)
.83 (21)
.83 (21)
.83 (21)

.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)
.63 (16)

.75 (19)
.87 (22)
.87 (22)
1.18 (30)
1.18 (30)
1.61 (41)
1.61 (41)
1.61 (41)
1.81 (46)
1.81 (46)
1.81 (46)

THREAD TYPE

Ex-e Conduit &


Fitting Systems

w/ Silicone O-Ring
RM-1612-6IX-D
RM-2012-6IX-D
RM-2016-6IX-D
RM-2516-6IX-D
RM-2520-6IX-D
RM-3216-6IX-D
RM-3220-6IX-D
RM-3225-6IX-D
RM-4020-6IX-D
RM-4025-6IX-D
RM-4032-6IX-D

Female
Thread
B

Silicone version
accommodates
-60C

Ex-e EMI / RFI Nickel


Plated Brass Glands

w/ Buna-N O-Ring
RM-1612-6X-D
RM-2012-6X-D
RM-2016-6X-D
RM-2516-6X-D
RM-2520-6X-D
RM-3216-6X-D
RM-3220-6X-D
RM-3225-6X-D
RM-4020-6X-D
RM-4025-6X-D
RM-4032-6X-D

Male
Thread
A

Ex-e Nickel Plated Brass &


Stainless Steel Glands

ATEX

w/ Silicone O-Ring
RM-1612-MIX-D
RM-2012-MIX-D
RM-2016-MIX-D
RM-2516-MIX-D
RM-2520-MIX-D
RM-3216-MIX-D
RM-3220-MIX-D
RM-3225-MIX-D
RM-4020-MIX-D
RM-4025-MIX-D
RM-4032-MIX-D

Female
Thread
B

Ex-e
Nylon Glands

w/ Buna-N O-Ring
RM-1612-MX-D
RM-2012-MX-D
RM-2016-MX-D
RM-2516-MX-D
RM-2520-MX-D
RM-3216-MX-D
RM-3220-MX-D
RM-3225-MX-D
RM-4020-MX-D
RM-4025-MX-D
RM-4032-MX-D

Male
Thread
A

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Silicone version
accommodates
-60C

Thread Reducers: Nickel Plated Brass Ex-d/Ex-e - Metric Threads


-4F to 203F
(-20C to 95C)

Ex-d EXIOS
Cable Glands

ATEX

Ex-e / Ex-d
Accessories

More Ex-d/Ex-e Adapters & Reducers


Options Available!
Sizes: Please Inquire
Thread Type: NPT, Metric, PG

Materials: Nylon, Bare Brass


Ratings/Approvals: Class/Division
800-456-9012

Dimensions, specifications and certifications may be changed without prior notice.

www.sealconex.com

53

Technical
Information

Ex-d EXIOS
Cable Glands

Red Fiber Washer & Grounding (Earth) Tags


Accessories - NPT / Metric Sizes - Ex-e

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Reinforced Nylon - Red Fiber


Seal Rings - NPT
Part Numbers
-76F to 221F
(-60C to 105C)

Seal Ring
Thickness

Page 59
for Thread
Specs

(Standard)

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Ex-e Multi-Hole &


Romex Glands

Ex-e
Nylon Glands

SR-09-FN
SR-13-FN
SR-21-FN
SR-29-FN
SR-54-FN
SR-36-FN
SR-20-FN
SR-52-FN
SR-30-FN

Fits
Thread
Size

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

3/8 NPT
1/2 NPT
3/4 NPT
1 NPT
1 1/4 NPT
1 1/2 NPT
2 NPT
2 1/2 NPT
3 NPT

Part Numbers
-76F to 221F
(-60C to 105C)

Seal
Ring
Thickness

Page 59
for Thread
Specs

(Standard)

SM-16-FN
SM-20-FN
SM-25-FN
SM-32-FN
SM-40-FN
SM-50-FN
SM-63-FN
SM-75-FN

Fits
Thread
Size

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

M16 x 1.5
M20 x 1.5
M25 x 1.5
M32 x 1.5
M40 x 1.5
M50 x 1.5
M63 x 1.5
M75 x 1.5

Thread
Size

Raw Brass (BB) &


Nickel Plated Brass
(BR) Grounding
(Earth) Tags are
installed between
the cable gland & equipment
to provide proper grounding.

(Raw Brass & NPB)

Page 59
for Thread
Specs

TN-09-BB
TN-13-BB
TN-21-BB
TN-54-BB
TN-36-BB
TN-20-BB
TN-52-BB
TN-30-BB

3/8 NPT
1/2 NPT
3/4 NPT
1 1/4 NPT
1 1/2 NPT
2 NPT
2 1/2 NPT
3 NPT

TN-13-BR
TN-21-BR
TN-29-BR

1/2 NPT
3/4 NPT
1 NPT

TM-20-BB
TM-25-BB
TM-32-BB
TM-40-BB
TM-50-BB
TM-63-BB
TM-75-BB

M20 x 1.5
M25 x 1.5
M32 x 1.5
M40 x 1.5
M50 x 1.5
M63 x 1.5
M75 x 1.5

Serrated Washers & Shrouds - Accessories


NPT / Metric Sizes - Ex-e
Serrated Washers - NPT

Ex-e Conduit &


Fitting Systems

Ex-e EMI / RFI Nickel


Plated Brass Glands

Part Numbers
-4F to 203F
(-20C to 95C)

Fits
Thread
Size

(Stainless Steel: AISI 316)

Page 59
for Thread
Specs

WN-09-SS
WN-13-SS
WN-21-SS
WN-29-SS
WN-54-SS
WN-36-SS
WN-20-SS
WN-52-SS
WN-30-SS

3/8 NPT
1/2 NPT
3/4 NPT
1 NPT
1 1/4 NPT
1 1/2 NPT
2 NPT
2 1/2 NPT
3 NPT

Shroud - NPT & Metric

Serrated Washers - Metric


Part Numbers
-4F to 203F
(-20C to 95C)

Fits
Thread
Size

(Stainless Steel: AISI 316)

Page 59
for Thread
Specs

WM-16-SS
WM-20-SS
WM-25-SS
WM-32-SS
WM-40-SS
WM-50-SS
WM-63-SS
WM-75-SS

M16 x 1.5
M20 x 1.5
M25 x 1.5
M32 x 1.5
M40 x 1.5
M50 x 1.5
M63 x 1.5
M75 x 1.5

Part Numbers

Fits
EXIOS
Size

Page 59
for Thread
Specs

(PVC)

SE-2K-PV
SE-2M-PV
SE-2L-PV
SE-25-PV
SE-32-PV
SE-40-PV
SE-50-PV
SE-63-PV
SE-75-PV

Fits
Thread
Size

20-1
20-2
20-3
25
32
40
50
63
75

3/8 NPT / M20


1/2 NPT / M20
1/2 NPT / M25
3/4 NPT / M25
1 NPT / M32
1-1/4 NPT / M40
2 NPT / M50
2-1/2 NPT / M63
3 NPT / M75

Provides additional weather and corrosion protection for


Cable Glands in Hazardous locations.

Ex-e / Ex-d
Accessories

Technical
Information

Grounding (Earth) Tags


Part Numbers
Thread
Type
-4F to 203F
(-20C to 95C)
& Size

Reinforced Nylon - Red Fiber


Seal Rings - Metric

54

www.sealconex.com

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Ex-e
Nylon Glands

Ex-e Multi-Hole &


Romex Glands

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Ex-e EMI / RFI Nickel


Plated Brass Glands

Ex-e Conduit &


Fitting Systems

Ex-e / Ex-d
Accessories

Our Service makes the difference!

Non-Hazloc Products

UL746C
f1

Technical
Information

800-456-9012

Ex-d Nickel Plated Brass &


Stainless Steel Glands

55
55

www.sealconex.com

Committed To Excellence!

Ex-d EXIOS
Cable Glands

Liquid Tight Cable Gland Fittings,


Accessories & Conduit System

Ex-d EXIOS
Cable Glands

M23 Circular Connectors (RJ45 Ethernet)


Nickel Plated Brass - Ex-i

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Ideal in Low Voltage Applications!


IP 67 (NEMA 4x)
EMI Ready
Available in Nickel Plated Brass
& Stainless Steel (316L)

Ex-e
Nylon Glands

SCADA
RTUs
Data Collection

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Ex-e Multi-Hole &


Romex Glands

Check Online at www.sealconex.com for latest


information and new product release!

M23 Circular Connectors (Signal / Power)


Nickel Plated Brass - Ex-e
For Non-Armored Cable

Ex-e EMI / RFI Nickel


Plated Brass Glands

Ex-e Circular Connectors


Panel Mount
Connectors

Ex-e Conduit &


Fitting Systems

(Back)

Technical
Information

Ex-e / Ex-d
Accessories

(Front)

Comin

Approvals Pending (Please ask for Details)


Power: 6 & 8-pos, 630 Volt
Signal: 8, 12, 16, 17 & 19-pos
IP67 (NEMA 4x)
-40C - 95C (-40F - 203F)
ATEX Class 1, Zone 1 & 2
Class 2, Zone 20, 21 & 22

Straight
Connectors

g Soo

56

www.sealconex.com

Straight
Panel Mount
Connectors

n!

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Ex-d EXIOS
Cable Glands

Circular Connectors
(M16, M23, M27, M40, RJ45, PoE)

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Our Service makes the difference!

Non-Hazloc Products
M23

Power

Signal

Ex-e
Nylon Glands

Signal: 3-28 pins (8-20 Amps)


Power: 6, 8, 9 & 10 pins (8-55 Amps)
Types: (Standard) Nickel Plated Brass & Stainless Steel,
Straight, Elbow, Panel Mount, Single Hole, Over-mold, RJ45 &
PoE (Power Over Ether); Nickel Plated Brass & Stainless Steel
(316L) Straight, Elbow (Angled) Panel, Single Hole
Applications: Robotic, Medical, Motion Control Technology,
Automation, Packaging, Sensors, Renewable Energy, etc.
Quick
Disconnect

PoE
RJ45

Ex-e Multi-Hole &


Romex Glands

Locks with a simple rotation!

Ex-e Nickel Plated Brass &


Stainless Steel Glands

M16
M12/M16 & M16
M40
M27
STAINLESS STEEL

Ex-e EMI / RFI Nickel


Plated Brass Glands

Fewer Parts & Reduced


Assembly Time!

Introduction
Marketing Segment

Ex-e Conduit &


Fitting Systems

Chemical Industries

Recycling

Refineries

Pharmaceutical

Motion Control

Oilfield Service Companies

Waste

Construction

The Petroleum Industry

Wood Processing

Textile

Energy/Coal

Agriculture

Marine

Process Industry

Metal

International Companies

Paint Manufacturing

Food Processing

Industrial Manufacturing Sector


www.sealconex.com

57

Technical
Information

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Ex-e / Ex-d
Accessories

Oil & Gas Production

Ex-d EXIOS
Cable Glands

Technical Information
Torque Specifications & Thread Diameter
Sizes & Dimensions for SEALCON Liquid Tight Cable Glands

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Ex-e Multi-Hole &


Romex Glands

Ex-e
Nylon Glands

M12 1.5

M16 x 1.5

16.0 mm / .63

14.5 mm / .57

M20 x 1.5

20.0 mm / .79

18.5 mm / .72

M25 x 1.5

25.0 mm / .98

M32 x 1.5

32.0 mm / 1.26 30.5 mm / 1.20

PG

Major Thread Minor Thread


Diameter
Diameter

PG 7
PG 9

12.5 mm / .49
15.2 mm / .60

11.3 mm / .44
13.9 mm / .54

PG 11

18.6 mm / .73

17.3 mm / .68

PG 13
PG 16

20.4 mm / .80
22.5 mm / .89

19.1 mm / .75
21.2 mm / .83

NPT

Major Thread Minor Thread


Diameter
Diameter

3/8

16.8 mm / .66

15.2 mm / .60

1/2
1/2-E

20.8 mm / .82
20.8 mm / .82

18.8 mm / .74
18.8 mm / .74

PG 21 28.3 mm / 1.11 26.8 mm / 1.05

3/4

26.2 mm / 1.03

24.1 mm / .95

PG 29 37.0 mm / 1.46 35.5 mm / 1.39

1
1-1/4

32.8 mm / 1.29 30.5 mm / 1.20


41.4 mm / 1.63 38.1 mm / 1.50

PG 36 47.0 mm / 1.85 45.5 mm / 1.79

1-1/2

47.8 mm / 1.88 45.7 mm / 1.80

23.5 mm / .92

M40 x 1.5

40.0 mm / 1.57 38.5 mm / 1.51

M50 x 1.5

50.0 mm / 1.97 48.5 mm / 1.90


PG 42 54.0 mm / 2.13 52.5 mm / 2.13
PG 48 59.3 mm / 2.33 57.8 mm / 2.27

M63 x 1.5
M75 x 1.5
M90 x 1.5

63.0 mm / 2.48 61.5 mm / 2.42


75.0 mm / 2.95
NA*
90.0 mm / 3.54
NA*

74.85 mm / 2.95
89.8 mm / 3.54

2
60.33mm / 2.35
2-1/2 73.03 mm / 2.86
3
88.9 mm / 3.5

Determine Sizes & Type of Fitting:

Ex-e Nickel Plated Brass &


Stainless Steel Glands

1.

2.
3.
4.

Check markings on the hex portion (wrenching flats). PG, NPT or Metric size should be embedded.
This only applies to Nylon parts.
Measure major thread diameter and compare with chart above. This may tell you whether it is a
PG, NPT or Metric thread (Nylon or Brass)
Confirm grommet type inside fitting. (See table on right for grommet identification)
The shading (grouping) indicates same size bodies, but different threads.

Note:

Dome Opening = the largest possible dimension for one or more cables.
The chart can also be useful when working with knockouts (drilling holes)

NA*
NA*
NA*

Dome
Opening
6.5 mm / .26
6.5 mm / .26
8.0 mm / .31
8.0 mm / .31
10.0 mm / .39
12.0 mm / .47
12.0 mm / .47
14.0 mm / .55
18.0 mm / .71
18.0 mm / .71
25.0 mm / 0.98
25.0 mm / 0.98
25.0 mm / 0.98
32.0 mm / 1.26
32.0 mm / 1.26
38.0 mm / 1.50
38.0 mm / 1.50
44.0 mm / 1.73
67.5 mm / 2.66
81.5 mm / 3.21
3.175 mm/ 1.25

Grommet Identification
Color
Type of Grommet
Black
Gray
Beige
Green
Red

Standard
Reduced
Multi-Hole / Solid Plug
FPM
Silicone

Recommended Torque Specifications for HSK Cable Glands Only

Ex-e EMI / RFI Nickel


Plated Brass Glands

Torque in lb/in = pound / inch (Nm) Newton Meters


Plastic Fittings
Dome Nuts
13.28 (1.50)
17.70 (2.0)
26.55 (3.0)
39.83 (4.5)
39.83 (4.5)
44.2 (5)
57.53 (6.5)
88.51 (10.0)
132.76 (15.0)
159.31 (18.0)
NA*
NA*
NA*
NA*

Sizes

Ex-e Conduit &


Fitting Systems

PG7, M12 x 1.5


PG9, PG11, 3/8 NPT, M16 x 1.5
1/2NPT ENLARGED, M16x1.5 ENLARGED
PG13.5, PG16, 1/2 NPT, M20 x 1.5
M20 x 1.5 ENLARGED
PG21, M25 x 1.5, 3/4NPT,
PG29, M32 x 1.5, 1 NPT
PG36, 1-1/2NPT, M40 x 1.5
PG42, PG48, M50 x 1.5
M63 x 1.5
M75 x 1.5
2 NPT
2-1/2 NPT
M90 x 1.5

Ex-e / Ex-d
Accessories

Technical
Information

Major Thread Minor Thread


Diameter
Diameter
12.0 mm / .47 10..5 mm / .41

Metric

Note:

Torque for dome nuts was determined using a metal rod. It may vary for cable, depending on the crush resistance of the cable.
To determine the actual torque empirically, we recommend testing the actual cable used. The values shown above are for reference only.
Torque Specification is based on Norm: EN 50262

Pull-Test Rating for Cable Glands


The Pull-Test Rating of our Cable Glands complies with Industry Standards.
Pull-Test Rating: Up To 35 lbs.
58

Metal Fittings
Dome Nuts
35.40 (4.0)
53.10 (6.0)
44.25 (5.0)
70.81 (8.0)
88.51 (10)
106.21 (12.0)
132.76 (15.0)
132.76 (15.0)
212.42 (24.0)
265.53 (30.0)
354.03 (40.0)
398.28 (45.0)
541.04 (60.0)
1062.09 (120.0)

www.sealconex.com

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Ex-d EXIOS
Cable Glands

Technical Information
Thread Specifications & Pitch: NPT / Metric / PG
Thread Specifications`
Thread Size

3/8 NPT

1/2 NPT

3/4 NPT

1-1/4 NPT

1-1/2 NPT

Major Dia. in Inches (mm)

.675 (17.145)

.84 (21.336)

1.05 (26.67)

1.314 (33.40) 1.66 (42.164)

1.90 (48.26)

Pitch in Inches (mm)


Number of Pitch n

.056 (1.411)

.071 (1.814)

.071 (1.814)

.087 (2.208)

.087 (2.208)

.087 (2.208)

.087 (2.208)

.125 (3.175)

18

14

14

11 1/2

11 1/2

11 1/2

11 1/2

60

1 NPT

2 NPT

Ex-d Nickel Plated Brass &


Stainless Steel Glands

NPT Threads
3

2.375 (60.325) 3.50 (88.9)

Pitch

conicity: 6.25%

Ex-e
Nylon Glands

NPT Thread = National Pipe Thread


Taper rate for all NPT threads is 1/16
The taper on NPT threads allows them to form a seal when torqued as the
flanks of the threads compress against each other, as opposed to straight
thread fittings
90

Ex-e Multi-Hole &


Romex Glands

Metric Threads
Thread Size

M12

M16

M20

M25

Major Dia. in Inches (mm)

.47 (12)

.63 (16)

.79 (20)

.98 (25)

Pitch in Inches (mm)


Thru hole in inches (mm)

.059 (1.5)

.059 (1.5)

.492 (12.5)

.63 (16)

M90

2.36 (60)

2.95 (75)

.059 (1.5) .059 (1.5) .059 (1.5) .059 (1.5) .059 (1.5) .059 (1.5)

.059 (1.5)

.79 (2.0)

2.36 (60)

2.95 (75)

.79 (20)

M32

.98 (25)

M40

M50

M63

1.26 (32) 1.57 (40) 1.97 (50) 2.48 (63)

Ex-e Nickel Plated Brass &


Stainless Steel Glands

60

M75

1.26 (32) 1.57 (40) 1.97 (50) 2.48 (63)

Most commonly used thread type world-wide


Characterized by its major diameter and its pitch
Designated by the letter M followed by the value of the nominal diameter and
the pitch, both expressed in millimeters and separated by the multiplication
sign (i.e. M12 x 1.5)

Pitch

PG Threads
PG 7

PG 9

PG 11

PG 13 / 13.5

Major Dia. in Inches (mm)

.49 (12.5)

.60 (15.2)

.73 (18.6)

.80 (20.4)

.89 (22.5) 1.11 (28.3)

PG 16

PG 21

PG 29

PG 36

1.46 (37)

1.85 (47)

PG 42

Pitch in Inches (mm)


Thru hole in inches (mm)

.05 (1.27) .055 (1.41) .055 (1.51)

.055 (1.51)

.055 (1.51) .062 (1.59) .062 (1.59) .062 (1.59) .062 (1.59) .062 (1.59)

.50 (12.7) .606 (15.4) .74 (18.8) .8149 (20.7) .897 (22.8) 1.12 (28.6) 1.47 (37.4) 1.87 (47.5) 2.14 (54.5) 2.35 (59.8)

Ex-e EMI / RFI Nickel


Plated Brass Glands

Thread Size

PG 48

2.13 (54) 2.39 (59.3)

80
Pitch

Ex-e Conduit &


Fitting Systems

PG Thread = Panzer-Gewinde (Panzer-Rohr-Gewinde)


German thread type
Depth of thread smaller than NPT or Metric, but larger flank
angle

Ex-e / Ex-d
Accessories

Other Technical Information


can be found online at

www.sealconex.com

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

www.sealconex.com

59

Technical
Information

For questions please call our Inside Technical Sales Department - 1-800-456-9012 or 303-699-1135.

Ex-d EXIOS
Cable Glands

Technical Information
Euro Zone & North American Class / Div / Group
Our products have been approved by many different certification authorities.
HUMMEL AG is a certified manufacturer and supplier of electro-mechanical devices.

ge
n
ox
y

For an explosion to occur, three conditions must be fulfilled; see the explosion triangle diagramm.
1. Fuel
2. Oxygen
3. Source of Ignition
By eliminating one of these three conditions, an explosion cannot occur.

n
itio
ign
of
fuel

Ex-e
Nylon Glands

Potentially Explosive Atmosphere


A potentially explosive atmosphere is understood to be a mixture of a combustible material and oxygen. Oxygen is generally present as a component of air. Combustible materials can be gases, fluids, vapors, mist or dusts. If the proportion of oxygen falls below a certain value dependent
on the material, known as the oxygen limit concentration, then this mixture cannot be ignited.
Zone 2

Ex-e Multi-Hole &


Romex Glands

lower
explosion
limit

ideal or
stoichiometric
mixture

upper
explosion
limit

Zone 0
Zone 1

Zone 0
lean mixture

European Zones / IEC /


CENELEC / ATEX
Classification

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Zone 0 (Gases)
Zone 20 (Dust)
Zone 1 (Gases)

explosion atmosphere

rich mixture

North American
Classification

Definition of Zone or Division


Relates to areas in which a potentially explosive atmosphere consisting of a mixture of air
and gases, vapors or mist exists continuously (Zone 0), or a mixture of dust and air exists
continuously (Zone 20) for long periods or frequently

Class I, Division 1 (gases)

Relates to areas in which a potentially explosive atmosphere of gases, vapors or mist


(Zone 1) or a mixture of dust and air (Zone 21) occurs occasionally

Class I, Division 1 (gases)

Relates to areas in which it is unlikely that a potentially explosive atmosphere of gases,


vapors or mist might occur (Zone 2) or (note the difference between conductive and
non-conductive dust!) relates to areas in which it is unlikely that a potentially explosive
atmosphere of suspended dust might occur (Zone 22), but if it does, only seldom and for
a short period of time

Class I, Division 2 (gases)

Zone 21 (Dust)
Zone 2 (Gases)
Zone 22 (Dust)

Class II, Division 1 (dust)

Class II, Division 1 (dust)

Class II, Division 2 (dust)


Class III, Division 1 (fibers)

Ex-e EMI / RFI Nickel


Plated Brass Glands

Class III, Division 2 (fibers)

Apparatus Group and Device Category EPL

Gases and Dust

Group I Mining
M1 High Degree of Safety EPL Ma
M2 High Degree of Safety EPL Mb

Gas
IIA
Propane
IIB
Ethylene
IIC
Hydrogene

Ex-e Conduit &


Fitting Systems

Group II Non-Mining
1 Very High Degree of Safety
Gas (Zone 0,1, 2) EPL Ga
Dust (Zone 20, 21, 22) EPL Da
2 High Degree of Safety
Gas (Zone 1, 2) EPL Gb
Dust (Zone 21, 22) EPL Db
3 Normal Degree of Safety
Gas (Zone 2) EPL Gc
Dust (Zone 22) EPL Gc

Ex-e / Ex-d
Accessories

Technical
Information

explosion
triangle

What is an explosion?

ce
ur
so

Ex-d Nickel Plated Brass &


Stainless Steel Glands

ATEX

Dust
IIIA
IIIB
IIIC

Combustible Dust
Non-Conductive Dust
Conductive Dust

Temperature Classes

Temperature
Class
T1
T2
T3
T4
T5
T6

Highest Permissible
Surface Temperature
of the Operating Facility
450C
300C
200C
135C
100C
85C

Ignition Temperature of
Combustible Materials
> 450C
> 300C < 450C
> 200C < 300C
> 135C < 200C
> 100C < 200C
> 85C < 100C

Disclaimer / Terms of Use


The information provided herein is provided as a general reference regarding the use of the applicable products in generic applications. This information is provided
without warranty. It is your responsibility to ensure that you are using all mentioned products properly in your specific application although this presentation strives to
maintain accurate and relevant information. There is no official guarantee that the information provided herein is accurate or has changed. If you use the information
provided herein in your specific application, please double check its applicability and be advised that you are using this information at your own risk. The purchaser of
the product must confirm the suitability of the product for the intended use, and assume all risk and liability in connection with its use.

60

www.sealconex.com

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Ex-d EXIOS
Cable Glands

Technical Information
Protection Ratings & Certifications

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Protection Concepts
Electrical
Ex-ia
Ex-ib
Ex-ic

IEC 60079-11 / EN 60079-11


IEC 60079-11 / EN 60079-11
IEC 60079-11 / EN 60079-11

Zone 0, 1, 2
Zone 1, 2
Zone 2

Limit the energy

Increased safety

Ex-e

IEC 60079-7 / EN 60079-7

Zone 1, 2

Non arcs, sparks or


hot surfaces, IP54 or better

Flameproof enclosure

Ex-d

IEC 60079-1 / EN 60079-1

Zone 1, 2

Contain the explosion


Use a flamepath

Ex-t

IEC 60079-31 / EN 60079-31

Zone 20,21,22

Dust tight enclosure IP6X

Ex-e
Nylon Glands

Intrinsic safety
Intrinsic safety
Intrinsic safety

Dust Protection

Ex-e Multi-Hole &


Romex Glands

Enclosure

Additional International Ex-Certifications, Installation Instructions, Approvals &


Licence Numbers for Cable Glands, Cable Glands can be found online at
http://sealconex.com/certificates.htm

Ex-e Nickel Plated Brass &


Stainless Steel Glands

IP 20

IP 21

IP 22

IP 23

Protected against solid foreign


object larger in diameter than
2.5 mm

IP 3x

IP 30

IP 31

IP 32

IP 33

IP 34

Protected against access


to hazardous parts with a wire
larger in diameter than 1.0 mm

Protected against solid foreign


objects larger in diameter than
1.0 mm

IP 4x

IP 40

IP 41

IP 42

IP 43

IP 44

Protected against access


to hazardous parts with a wire
larger in diameter than 1.0 mm

Prevent penetration of dust


sufficient to cause damage inside
the equipment.

IP 5x

IP 50

Protected against access


to hazardous parts with a wire
larger in diameter than 1.0 mm

Dust proof

IP 6x

IP 60

IP 00

Protected against access to


hazardous parts with the back
of the hand

Protected against soild foreign


objects larger in diameter than
50 mm

IP 1x

Protected against access to


hazardous parts with a finger

Protected against soild foreign


objects larger in diameter than
12.5 mm

Protected against access to


hazardous parts with a tool
larger in diameter than 25 mm

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

IP 54

Protection against
permanent submersion

Water splashed from any


direction shall have no
harmful effects

IP 2x

IP 0x

Protection against
temporary submersion

Water sprayed at an angle up to


60 on either side of the vertical
shall have no harmful effects

IP 12

Non-protected

Water projected in powerful


jets from any direction shall
have no harmful effects

Protected against vertically


falling water drops when
device is tilted up to 15

IP 11

Non-protected

Water projected in jets from


any direction shall have no
harmful effects

Protection against drip water


(or dripping water)

IP 10

Penetration of water

IP x4

2. Code

IP x3

IP x5

IP x6

IP x7

IP x8

IP 66

IP 67

IP 68

IP 55

IP 65

www.sealconex.com

61

Technical
Information

IP x2

Protection of equipment
against penetration of solid
foreign objects

Ex-e / Ex-d
Accessories

IP x1

Protection against human


access to hazardous parts

Ex-e Conduit &


Fitting Systems

IP x0

1. Code

Ex-e EMI / RFI Nickel


Plated Brass Glands

Non-protected

International Protection, EN 60529

Ex-d EXIOS
Cable Glands

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Ex-e
Nylon Glands

Ex-e Multi-Hole &


Romex Glands

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Ex-e EMI / RFI Nickel


Plated Brass Glands

Ex-e Conduit &


Fitting Systems

Ex-e / Ex-d
Accessories

Technical
Information

Index / Cross Reference


www.sealconex.com
Sealcon
Hummel
Part Numbers
Part Numbers
CCxxAx-EX
1.646
CCxxAx-EXZ
1.641
CCxxAx-FX
1.637
CCxxAx-MX, Cx-MX
1.640
CCxxAx-SX
1.642
CCxxMx-6X-D
1.632
CCxxMx-EX
1.646
CCxxMx-EXZ
1.641
CCxxMx-EZ-D
1.628
CCxxMx-FX, Dx-FX
1.637
CCxxMx-MX
1.640
CCxxMx-MX-D
1.622
CCxxMx-SX
1.642
CCxxNx-6X-D
1.632
CCxxNx-EX
1.646
CCxxNx-EXZ
1.641
CCxxNx-EZ-D
1.628
CCxxNx-MX
1.640
CCxxNx-MX-D
1.622
CDxxAA-BX
1.291
CDxxAA-CP
1.215
CDxxAA-EX
1.616
CDxxAA-EX-V
1.666
CDxxAA-EXZ
1.617
CDxxAA-EXZ-V
1.667
CDxxAA-EZ
1.611
CDxxAA-EZ-V
1.661
CDxxAA-FX
1.636
CDxxAA-GX
1.291
CDxxAA-MX
1.610
CDxxAA-RX
1.660
CDxxAA-SX, -SX-V 1.612, 1.662
CDxxAA-UX
1.291
CDxxAR-BX
1.291
CDxxAR-EX
1.616
CDxxAR-EX-V
1.666
CDxxAR-EXZ
1.617
CDxxAR-EXZ-V
1.667
CDxxAR-GX
1.291
CDxxAR-MX
1.610
CDxxAR-RX
1.660
CDxxAR-SX, -SX-V 1.612, 1.622
CDxxAR-UX
1.291
CDxxAS-EBx
1.689
CDxxAS-Ex
1.589
CDxxAx-GX / -BX
1.599
CDxxAx-MX
1.687
CDxxCA-BX
1.291
CDxxCA-GX
1.291
CDxxCA-MX
1.610
CDxxCA-RX
1.660
CDxxCA-UX
1.291
CDxxCR-BX
1.291
CDxxCR-GX
1.291
CDxxCR-MX
1.610
CDxxCR-RX
1.660
CDxxCR-UX
1.291
CDxxDA-BX
1.291
CDxxDA-BXA
1.292
CDxxDA-FX
1.636
CDxxDA-GX
1.291
CDxxDA-MX
1.610
CDxxDA-RX
1.660
CDxxDA-UX
1.291
CDxxDR-BX
1.291
CDxxDR-BXA
1.292
CDxxDR-GX
1.291
CDxxDR-MX
1.610

62

www.sealconex.com

Hummel
Sealcon
Description
Page Nr.
HSK-M-Ex (Low Temp.)
42
HSK-MZ-Ex (Low Temp.)
44
HSK-M-EMV-D-Ex
43
HSK-M-Ex (Low Temp.)
36
HSK-M-Ex (Low Temp.)
40
HSK-INOX-Ex-d
16
HSK-M-Ex (Low Temp.)
41
HSK-MZ-Ex (Low Temp.)
44
HSK-MZ-Ex-d
15
HSK-M-EMV-D-Ex
43
HSK-M-Ex (Low Temp.)
35
HSK-M-Ex-d
14
HSK-M-Ex (Low Temp.)
40
HSK-INOX-Ex-d
16
HSK-M-Ex (Low Temp.)
41
HSK-MZ-Ex (Low Temp.)
44
HSK-MZ-Ex-d
15
HSK-M-Ex (Low Temp.)
35
HSK-M-Ex-d
14
HSK-K-Ex
21
HSK-K-MZ-Ex
25
HSK-M-EMV-Ex
42
HSK-M-EMV-PVDF-Ex
42
HSK-MZ-EMV-Ex
44
HSK-MZ-EMV-PVDF-Ex
44
HSK-MZ-Ex
37
HSK-MZ-PVDF-Ex
37
HSK-M-EMV-D-Ex
43
HSK-K-Ex
24
HSK-M-Ex
36
HSK-M-PVDF-Ex
39
HSK-INOX-Ex, -PVDF-Ex
40
HSK-K-Ex
21
HSK-K-Ex
21
HSK-M-EMV-Ex
42
HSK-M-EMV-PVDF-Ex
42
HSK-MZ-EMV-Ex
44
HSK-MZ-EMV-PVDF-Ex
44
HSK-K-Ex
24
HSK-M-Ex
36
HSK-M-PVDF-Ex
39
HSK-INOX-Ex, -PVDF-Ex
40
HSK-K-Ex
24
HSK-M-FLAKA-Ex
27
HSK-K-FLAKA-Ex
26
HSK-K-Multi-Ex
32-33
HSK-M-Multi-Ex
32-33
HSK-K-Ex
21
HSK-K-Ex
24
HSK-M-Ex
36
HSK-M-PVDF-Ex
39
HSK-K-Ex
21
HSK-K-Ex
21
HSK-K-Ex
24
HSK-M-Ex
36
HSK-M-PVDF-Ex
39
HSK-K-Ex
21
HSK-K-Ex
20
HSK-K-Ex-Active
18
HSK-M-EMV-D-Ex
43
HSK-K-Ex
23
HSK-M-Ex
35
HSK-M-PVDF-Ex
38
HSK-K-Ex
20
HSK-K-Ex
20
HSK-K-Ex-Active
18
HSK-K-Ex
23
HSK-M-Ex
35

Sealcon
Hummel
Part Numbers
Part Numbers
CDxxDR-RX
1.660
CDxxDR-UX
1.291
CDxxLx-BX
1.291
CDxxLx-BXA
1.292
CDxxLx-GX
1.291
CDxxLx-EZ-D
1.628
CDxxMA-6VX-D
1.633
CDxxMA-BX
1.291
CDxxMA-BXA
1.292
CDxxMA-CP
1.215
CDxxMA-EX
1.616
CDxxMx-EXZ
1.617
CDxxMA-EZ
1.611
CDxxMA-EZ-D
1.628
CDxxMA-EZ-V
1.661
CDxxMA-FX
1.636
CDxxMA-GX
1.291
CDxxMA-MX
1.610
CDxxMA-RX
1.660
CDxxMA-RX-D
1.634
CDxxMA-SX, -SX-V 1.612, 1.662
CDxxMA-UX
1.291
CDxxMR-6VX-D
1.633
CDxxMR-BX
1.291
CDxxMR-BXA
1.292
CDxxMR-EX
1.616
CDxxMR-EXZ
1.617
CDxxMR-EZ-V
1.661
CDxxMR-GX
1.291
CDxxMR-MX
1.610
CDxxMR-RX
1.660
CDxxMR-RX-D
1.634
CDxxMR-SX, -SX-V 1.612, 1.662
CDxxMR-UX
1.291
CDxxMS-EBx
1.689
CDxxMS-Ex
1.589
CDxxMx-GX / -BX
1.599
CDxxMx-MX
1.687
CDxxNA-6VX-D
1.633
CDxxNA-BX
1.291
CDxxNA-BXA
1.292
CDxxNA-EX
1.616
CDxxNA-EX-V
1.666
CDxxNA-EXZ
1.617
CDxxNA-EXZ-V
1.667
CDxxNA-EZ
1.611
CDxxNA-EZ-D
1.628
CDxxNA-EZ-V
1.661
CDxxNA-GX
1.291
CDxxNA-MX
1.610
CDxxNA-RX
1.660
CDxxNA-RX-D
1.634
CDxxNA-UX
1.291
CDxxNR-6VX-D
1.633
CDxxNR-BX
1.291
CDxxNR-BXA
1.292
CDxxNR-EX
1.616
CDxxNR-EX-V
1.666
CDxxNA-EXZ
1.617
CDxxNR-GX
1.291
CDxxNR-MX
1.610
CDxxNR-RX
1.660
CDxxNR-RX-D
1.634
CDxxNR-UX
1.291
CDxxNS-EBx
1.689
CDxxNS-Ex
1.589
CDxxNx-BX
1.599
CDxxNx-GX
1.599

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Hummel
Sealcon
Description
Page Nr.
HSK-M-PVDF-Ex
38
HSK-K-Ex
20
HSK-K-Ex, HSK-K-Multi
29
HSK-K-Ex-Active
19
HSK-K-Ex, HSK-K-Multi
29
HSK-M-MZ-Ex-d
15
HSK-INOX-PVDF-Ex-d
16
HSK-K-Ex
20
HSK-K-Ex-Active
18
HSK-K-MZ-Ex
25
HSK-M-EMV-Ex
41
HSK-MZ-EMV-Ex
44
HSK-MZ-Ex
37
HSK-M-MZ-Ex-d
15
HSK-MZ-PVDF-Ex
37
HSK-M-EMV-D-Ex
43
HSK-K-Ex
23
HSK-M-Ex
35
HSK-M-PVDF-Ex
38
HSK-M-PVDF-Ex-d
14
HSK-INOX-Ex, -PVDF-Ex
40
HSK-K-Ex
20
HSK-INOX-PVDF-Ex-d
16
HSK-K-Ex
20
HSK-K-Ex-Active
18
HSK-M-EMV-Ex
41
HSK-MZ-EMV-Ex
44
HSK-MZ-PVDF-Ex
37
HSK-K-Ex
23
HSK-M-Ex
35
HSK-M-PVDF-Ex
38
HSK-M-PVDF-Ex-d
14
HSK-INOX-Ex, -PVDF-Ex
40
HSK-K-Ex
20
HSK-M-FLAKA-Ex
27
HSK-K-FLAKA-Ex
26
HSK-K-Multi-Ex
30-31
HSK-M-Multi-Ex
30-31
HSK-INOX-PVDF-Ex-d
16
HSK-K-Ex
22
HSK-K-Ex-Active
19
HSK-M-EMV-Ex
41
HSK-M-EMV-PVDF-Ex
41
HSK-MZ-EMV-Ex
44
HSK-MZ-EMV-PVDF-Ex
44
HSK-MZ-Ex
37
HSK-M-MZ-Ex-d
15
HSK-MZ-PVDF-Ex
37
HSK-K-Ex
22
HSK-M-Ex
35
HSK-M-PVDF-Ex
38
HSK-M-PVDF-Ex-d
14
HSK-K-Ex
22
HSK-INOX-PVDF-Ex-d
16
HSK-K-Ex
22
HSK-K-Ex-Active
19
HSK-M-EMV-Ex
41
HSK-M-EMV-PVDF-Ex
41
HSK-MZ-EMV-Ex
44
HSK-K-Ex
22
HSK-M-Ex
35
HSK-M-PVDF-Ex
38
HSK-M-PVDF-Ex-d
14
HSK-K-Ex
22
HSK-M-FLAKA-Ex
27
HSK-K-FLAKA-Ex
26
HSK-K-Multi-Ex
28-29
HSK-K-Multi-Ex
28-29

57

Sealcon
Hummel
Part Numbers
Part Numbers
NN-xx-ST
NP-xx-BE
1.167
NP-xx-BK
1.262
NP-xx-BR
1.161
NP-xx-GY
1.262
NP-xx-SS
1.161
PV-xx-BX
1.296
RM-xxxx-6X-D
1.898
RM-xxxx-6IX-D
1.899
RM-xxxx-MX
1.078
RM-xxxx-MX-D
1.878
RM-xxxx-MIX-D
1.879
RM-xxxx-MX-S
1.079
RM-xxxx-SX
1.098
RM-xxxx-SX-S
1.099
RQ-xxxx-MX
1.078
RQ-xxxx-MX-S
1.079
RQ-xxxx-SX
1.098
RQ-xxxx-SX-S
1.099
SE-xx-PV
1.802
SF-xxxx-BX
1.560
SM-, SR-xx-FN
1.326
TN-, TM-xx-BB, -BR
1.022
WN-, WM-xx-SS
1.329
YAxxxx-BB
1.608
YExxxx-BB, B1
1.605
YPxxxx-BB, B1
1.606
YUxxxx-B1, BR
1.6U6
YZxxxx-BB, B1
1.605

Hummel
Description
GM-EMV
GM-FS
GM-Ms
GM-FS
GM-INOX
HSK-V-Ex
RSD-INOX-Ex-d
RSD-INOX-Ex-d-VMQ
RSD-Ms-Ex
RSD-Ms-Ex-d
RSD-Ms-Ex-d-VMQ
RSD-Ms-VMQ-Ex
RSD-INOX-Ex
RSD-INOX-VMQ-Ex
RSD-Ms-Ex
RSD-Ms-VMQ-Ex
RSD-INOX-Ex
RSD-INOX-VMQ-Ex
Snapflex-Ex
Red Fiber Washer
Earthtag
Serrated Washer
EXIOS A2F
EXIOS Standard
EXIOS Barrier
EXIOS UL Barrier
EXIOS MZ

Sealcon
Page Nr.
47
47
48
47
48
46
48
53
53
51
53
53
51
52
52
51
51
52
52
54
45
54
54
54
12
8
6
4
9

Sealcon - Hazloc Solutions


Qualifying Questions & Inquiry Form
Gland / SRF Material:

Cable Types:

Thread:

Ex-i
Ex-e
Ex-d
ATEX
IECEx
UL
CSA (cUS)
Other : ________

Brass
Nickel Plated
316 Stainless Steel
Nylon / Plastic
Snapflex / DUOFitting
Circular Connectors
Other: _________________

SWA (Steel Wire Armor) W


SWB (Steel Wire Braid) X
DST (Double-Steel Tape) Z
--(Lead Sheath)
--(Unarmored)
--(Tek/MC/Corrugated)

METRIC
NPT
Other: ______________

Euro Zone:
1

2 (Gas)

20

21

22 (Dust)

0 - 2.5 mm (up to 0.1)

-60 C to 105 C (EXIOS)


-20 C to 95 C (SRF)
-20 C to 130 C (PVDF)
Other:____________
IP Ratings:

Class 1 Div 1 (Gas)


Class 1 Div 2 (Gas)
Class 2 Div 1 (Dust)
Class 2 Div 2 (Dust)

66 67
68 Other:___

Cable Description:

Compound Filled:
Yes

Metric:
M12, M16, M20, M25, M32,
M40, M50, M63, M75
NPT:
3/8, , , 1, 1, 1,
2, 2, 3

No

Accessories:
Shrouds
Hex Plugs
Serrated Washers
Blind Plugs
Earth Tags
Adapters
Red Fiber Washer
Reducers
Lock Nuts
Breather Drain

Cable I.D. O.D:

Ex-e / Ex-d
Accessories

Class & Div

Armor thickness:

Sizes):

Ex-e Conduit &


Fitting Systems

Operating Temp:

Ex-e EMI / RFI Nickel


Plated Brass Glands

Ratings & Approvals:

Gland Quantity:

Quote

Catalog

Certifications

800-456-9012
Dimensions, specifications and certifications may be changed without prior notice.

Other

www.sealconex.com

63

Technical
Information

Requesting:
Sample

Ex-e Nickel Plated Brass &


Stainless Steel Glands

Sealcon
Page Nr.
28-29
45
50
50
50
49
50
50
49
49
50
50
50
50
49
49
49
49
50
50
50
45
47
48
47
48
46
47
47
48
47
48

Ex-e Multi-Hole &


Romex Glands

Hummel
Description
HSK-M-Multi-Ex
Snapclic-DUO-MX
V-INOX-Ex-d (Silicon)
V-INOX-Ex-d (Viton)
V-INOX-Ex-d (Buna-N)
V-Ex
V-INOX-Ex-d (Silicone)
V-INOX-Ex-d (Buna-N)
V-Ms-Ex (Silicone)
V-Ms-Ex (Viton)
V-INOX-Ex-d (Viton)
V-INOX-Ex
V-INOX-VMQ-Ex
V-INOX-FPM-Ex
V-Ex
V-Ms-Ex
V-Ms-VMQ-Ex
V-Ms-FPM-Ex
V-INOX-Ex
V-Ms-VMQ-Ex
V-INOX-FPM-Ex
Snapclip-Ex
GM-EMV
GM-FS
GM-Ms
GM-FS
GM-INOX
GM-Ms
GM-EMV
GM-FS
GM-Ms
GM-FS

Ex-e
Nylon Glands

Hummel
Part Numbers
1.687
1.566
1.897
1.896
1.895
1.297
1.896
1.895
1.199
1.198
1.897
1.192
1.193
1.194
1.297
1.197
1.199
1.198
1.192
1.193
1.194
1.731
1.167
1.262
1.161
1.262
1.161
1.161
-

Ex-d Nickel Plated Brass &


Stainless Steel Glands

Sealcon
Part Numbers
CDxxNx-MX
DUOxxMx-MX
HM-xx-6IX-D
HM-xx-6VX-D
HM-xx-6X-D
HM-xx-BX
HM-xx-MIX-D
HM-xx-MX-D
HM-xx-MX-S
HM-xx-MX-V
HM-xx-MVX-D
HM-xx-SX
HM-xx-SX-S
HM-xx-SX-V
HP-xx-BX
HP-xx-MX
HP-xx-MX-S
HP-xx-MX-V
HP-xx-SX
HP-xx-SX-S
HP-xx-SX-V
MC-xx-BX
NM-xx-BE
NM-xx-BK
NM-xx-BR
NM-xx-GY
NM-xx-SS
NM-xx-XL
NN-xx-BE
NN-xx-BK
NN-xx-BR
NN-xx-GY

Ex-d EXIOS
Cable Glands

Index / Cross Reference


www.sealconex.com

We Provide Customers with Cable Management Solutions!

Setting Standards
Hummel AG

Hummel AG

Hummel AG

Other catalogs & flyers available.


Call for details...

For the most current up to date information on


these products and everything else Sealcon has to
offer please visit our website:
www.sealconex.com
Our website is continuously updated. Sealcon
catalogs are also available for download online.
Look for your nearest Local Distributor online!

Committed to Excellence!

7374 S. Eagle Street


Centennial, CO 80112-4221 USA
Toll Free: 800-456-9012 / 303-699-1135
Fax: 303-680-5344
Email: infoex@sealconex.com
Web: www.sealconex.com
0415

Você também pode gostar