Product Benefits
A world-class ASCO
Automatic or Manual Power
Transfer Switch with digital microprocessor controller.
ASCO 7000 Series Power Transfer Load Center
with quick-connect Cam-Lok assembly
and Telco section
The area they demand, including mandated clearances, can total as much as 23 sq. feet for 200 or 400
Amp Services.
With space at a premium and more advanced communications technologies being installed at sites, it
makes sense to streamline and simplify site power
protection and distribution strategies.
ASCO Power
Transfer Switches
Square D 42-circuit
panel board
Telco cabinet
ASCO
Transient
Voltage Surge
Suppressor
Service
Breakers
ASCO
5500 Series
Thin Web
Server
ASCO 7000L
Power Transfer Switch
Load Center Product
Features
Conventional double throw
transfer switch configuration
Automatic Transfer Switch is
listed to UL1008, the standard for
Transfer Switch Equipment, and
meets NFPA 110 for Emergency
and Standby Power Systems and
the National Electrical Code
(NEC) articles 700,701, and 702.
Also certified to CSA 22.2
No. 178
Rated up to 240VAC, 200, or
400 amps
Available in Type 1 indoor, or
Type 3R secure aluminum
outdoor enclosure
Reliable and field proven single
solenoid operating mechanism
Programmable microprocessor
controller with keypad and LCD
display
16mm, industrial grade control
switches and indicating lights
Switch position LED indicators and
source acceptability lights
Four auxiliary contacts, two
contacts closed when switch is
in normal position and two
contacts closed when switch is
in emergency position
Local/remote communications
capability for interfacing with
ASCO PowerQuest communication products
Features
Digital microprocessor.
Touch pad programming of features and settings
without the need for meters, or variable power supplies.
Sixteen (16) selectable operating voltages available in a
single Controller.
On-board diagnostics provide control panel and ATS status information to analyze system performance.
Displays and counts down active timing functions.
Time Delays
Output signals for remote indication of normal and emergency source acceptability
The 7000 SERIES Microprocessor Based Controller is used with all sizes of Power
Transfer Switches from 30 through 4000 Amperes. It represents the most advanced
digital controller in the industry and includes, as standard, all of the voltage,
frequency, control, timing and diagnostic functions required for most emergency
and standby power applications.
Because of severe voltage transients frequently encountered with industrial
distribution systems, the microprocessor logic board is separated and isolated from
the power board as shown below. This improves electrical noise immunity performance
and helps assure compliance with the rigorous transient suppression standards highlighted below.
7000 Series
Microprocessor Controller.
EN 55011:1991
EN 50082-2:1995
EN 61000-4-2:1995
ENV 50140:1993
EN 61000-4-4:1995
EN 61000-4-5:1995
EN 61000-4-6:1996
EN 61000-4-11:1994
200
Load
Center
Poles
4 = 42
Space
2 poles,
1
Amperes
Voltage
Code
Continuous
Rating
200
400
3 poles,
3
208
240
Controller
Options
Insert X
if optional
accessories
are required
+ 240V 60Hz
Optional
Accessories2
Enclosure
73TL1
Type 1
(Standard)
11BG - Programmable
Engine Exerciser
Type 3R
Secure
(Outdoor)
14AA/14BA - Auxiliary
Contacts (2 Sets)1
37P - Generator
Receptacle 3
Specific
Voltage & Freq
This Information
is necessary
to allow correct
settings prior to
shipment
1. Available on 300L, Power Transfer Load Center only. (two sets are standard) for 7000L Series.
2. See page 12-15 for optional accessories.
3. Available for Type 3R enclosure only, rated 200 Amps. Not available for 400 Amp.
One
One
Two
200
400
Phase
Poles
Width
200
2,3
30(762)
78(1981)
6(152)
250(115)
400
2,3
38(965)
80(2032)
7-1/4(184)
300(138)
2,3
36(914)
53(1346)
11(279)
305(141)
2,3
38(965)
84(2134)
11-1/4(286)
325(149)
Switch Rating
Amps
Depth
Approx. Shipping
Weight Lb. (kg)
Enclosed UL Type1
Enclosed UL Type3R
Aluminum Secure
2001
400
1. Add 20 inches to the height of the type 3R enclosure if accessory 128TB, Telco cabinet is required.
See page 15 for description of optional Telco compartment.
Battery to
Maintain Engine
Exerciser Clock
Settings
Re-transfer to
Normal Adjustable
Time Delay
Transfer to
Emergency Adjustable
Time Delay
Customer Control
Interfaces
Performance Features
600 volt spacing per UL and CSA standards.
Interfacing relays are industrial grade, plug-in type with dust covers.
Meets or exceeds the requirements for Electromagnetic Compatibility (EMC).
The ASCO Series 300 Microprocessor Controller is used with all sizes of Power Transfer Switches. It represents the most
reliable microprocessor controller in the industry and includes, as standard, all of the voltage, frequency, control, timing and
connectivity functions required for most emergency and standby power applications.
Time Delays
10
200
Load
Center
Poles
4 = 42
Space
2 poles,
1
Amperes
Voltage
Code
Continuous
Rating
200
400
3 poles,
3
208
240
Controller
Options
Insert X
if optional
accessories
are required
Enclosure
C
M
73TL1
Optional
Accessories2
Type 1
(Standard)
11BG - Programmable
Engine Exerciser
Type 3R
Secure
(Outdoor)
14AA/14BA - Auxiliary
Contacts (2 Sets)1
37P - Generator
Receptacle 3
+ 240V 60Hz
Specific
Voltage & Freq
This Information
is necessary
to allow correct
settings prior to
shipment
1. Available on 300L, Power Transfer Load Center only. (two sets are standard) for 7000L Series.
2. See page 12-15 for optional accessories.
3. Available for Type 3R enclosure only, rated 200 Amps. Not available for 400 Amp.
One
One
Two
200
400
Phase
Poles
Width
200
2,3
30(762)
78(1981)
6(152)
250(115)
400
2,3
38(965)
80(2032)
7-1/4(184)
300(138)
2,3
36(914)
53(1346)
11(279)
305(141)
2,3
38(965)
84(2134)
11-1/4(286)
325(149)
Switch Rating
Amps
Depth
Approx. Shipping
Weight Lb. (kg)
Enclosed UL Type1
Enclosed UL Type3R
Aluminum Secure
2001
400
Note: 1. Add 20 inches to the height of the type 3R enclosure if accessory 128TB, Telco cabinet is required.
(see pg. 15 for Telco compartment description)
11
ASCO 7000 Series and Series 300 Power Transfer Load Centers - Optional Accessories
Accessory 11BG
A programmable engine exerciser that provides for
weekly or bi-weekly operation, includes one form C contact for source availability of normal and one contact for
availability of emergency (contact rating 2 amps @ 30
Vdc, 0.5 amp @ 125 Vac resistive). The programmable
engine exerciser incorporates a 7 day or 14 day time base
with a digital readout display. Includes with or without
load control selection for exerciser period. Available on
Series 300L Power Transfer Switch Load Center only, not
required for 7000L Series.
Accessory 73V
Transient voltage surge suppression. ASCO 458 series with
integral LED status indication per phase (Service Available &
Status OK), One (1) Form C contact connected to terminal
block to signal overall status OK.
Single Phase
73VN1: (1) TVSS connected to Normal source only
73VB1: (2) TVSS connected to Normal and Emergency sources
73VL1: (1) TVSS connected to the Load source only
Three Phase
73VN3: (1) TVSS connected to Normal source only
73VB3: (2) TVSS connected to Normal and Emergency sources
73VL3: (1) TVSS connected to Load source only
Alternate TVSS offering: Load Surge Suppressor:
Located at line side of panelboard, ASCO 510 series
with phase monitoring alarm, and load phase voltage
availability indicators (LED)
Single phase 73TL1: (2) TVSS connected to Load source only
Three phase 73TL3: (3) TVSS connected to Load source only
All TVSS UL 1449 3rd Edition Listed
12
Accessory 130MG
Accessory 117IB
Generator selector circuit breaker (emergency source #1 &
emergency source #2). One each for two/three pole,
200/400A circuit breaker for two separate generator
inputs (UL Listed).
200A - Manual slide type interlock to permit connection
of only one generator to the transfer switch emergency
source input.
400A Walking Beam interlock to permit connection
of only one generator to the transfer switch emergency
source input.
Accessory 85L
Power Manager for load monitoring. The Electronic
Access Module (EAM) provides measurement of voltage,
frequency, and current, and calculation of power,
energy, and power factor.
The data monitor is connected to measure single phase 2
or 3 wire, or three phase 3 or 4 wire systems based on the
configuration of the Power Transfer Load Center.
13
14
Accessory 14AA/14BA
Auxiliary contacts to indicate position of main contacts.
Two (2) for normal and two emergency position (one set is
standard). Available on 300L, Power Transfer Load Center
only, (two sets are standard) for 7000L Series (7000 ATS
shown)
Accessory 128TB
15
EmersonNetworkPower.com
Outside Plant
AC Power
Connectivity
Embedded Computing
Embedded Power
DC Power
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. 2009 Emerson Electric Co.
Publication 3213
September, 2009