Escolar Documentos
Profissional Documentos
Cultura Documentos
CANADA
CNS Automation, Inc.
14251 E. Firestone Blvd. La Mirada, CA 90638
Tel : 562-404-1909 Fax : 562-404-1902
U.S.A / CANADA
USA
Hyundai Elevator
Hyundai Elevator Head Office_The World Class Elevator Test Tower (Hyundai Asan Tower) stands in Icheon, Korea
Company Profile
Incorporated : May 23, 1984
Number of Employees : 1,304(As of September, 1, 2012)
Factory
The selection of elevator speed/model should be made in consideration of the building type,
size, use and the anticipated passenger carrying capacity at peak traffic times.
R&D Center
R & D Center was established in 1986 and employs over 100 employees and is
the core of our new product development.
Type of Machine
Model
(Unit:fpm[m/s])
Test Tower
Standing 672ft(205m) high, our ultra- high speed test tower, named the
Hyundai Asan Tower, was completed in April 2009 and is used to test for
vibration, noise, pressure, as well as the reliability and safety of the parts and
components related to ultrahigh speed systems.
350(1.75)
200(1.0)
At the Hyundai Asan Tower, you will find the worlds fastest elevator running
at speeds up to 3600fpm(18m/sec), as well as the 2000fpm(10m/sec), high speed double
deck elevator, and the worlds fastest 1400fpm(7m/sec) high speed observation elevator.
150(0.75)
Contents
01 Reliable Products YZER04 / LUXEN06
02 Advanced Technology Gearless Traction Machine08
03 Design Design Collection10 / Ceiling Design & Handrail17 / Signal Fixtures18
Standard & Optional Features20 / Layout Plan22 / Entrance Design26 / Power Feeder Data28 / Works To Be Done By Other Contractors29
* MRL: Machine-room-less
HYUNDAI ELEVATOR RELIABLE PRODUCTS
Machine-room-less
elevators (YZER)
The machine roomless elevator YZER is a revolutionary new elevator that eliminates
the need for a rooftop machine room through the use of miniaturized traction machines and control panels,
allowing increased space utilization, resolution of height and sunlight restriction issues, and more freedom
in installation layout and skyline design.
PASSENGER ELEVATORS5
01Reliable Products
HYUNDAI ELEVATOR RELIABLE PRODUCTS
Energy efficiency
Gearless traction machine with permanent magnet synchronous
motor increases energy efficiency.
Eco-friendly
Environmentally-friendly elevator that does not need regular gear
oil replacement.
PASSENGER ELEVATORS7
01Reliable Products
02 Advanced Technology
Gearless
Traction Machine
With the use of gearless traction machine, smoother ride, improved energy-saving,
and environment-friendly features are enhanced.
Comfortable ride
Noise and vibration level has decreased dramatically and
car ride has improved significantly with the use of gearless traction machines
with permanent magnet synchronous motors thanks to the lack of tooth
gear and rope swing.
Environment-friendly components
Gearless traction machine is environment-friendly since gear oil is not
required.
PASSENGER ELEVATORS9
DESIGN
COLLECTION
DESIGN
COLLECTION
FRONT VIEW
CAGE DESIGN
REAR VIEW
ENTRANCE
ENTRANCE
FRONT VIEW
CAGE DESIGN
ENTRANCE
ENTRANCE
Door
Painted Steel(P017)
Ceiling
Door
Painted Steel(P016)
Jamb
Wall
Jamb
Wall
Hall Button
Hall Button
Handrail
Handrail
Car Doors
Painted Steel(P017)
Car Doors
Painted Steel(P016)
Operating Panel
Operating Panel
Car Lantern
Car Lantern
Flooring
Marble(By Others)
Flooring
Marble(By Others)
Ceiling
PASSENGER ELEVATORS11
03Design Collection
REAR VIEW
DESIGN
COLLECTION
DESIGN
COLLECTION
FRONT VIEW
CAGE DESIGN
REAR VIEW
ENTRANCE
ENTRANCE
FRONT VIEW
CAGE DESIGN
Ceiling
Door
Stainless Hairline(#4)
Wall
Jamb
Handrail
FL / Stainless Hairline(#4)
Hall Button
Car Doors
Stainless Hairline(#4)
Indicator
Operating Panel
Handrail
Car Lantern
Car Doors
Stainless Hairline(#4)
Flooring
Marble(By Others)
Operating Panel
Car Lantern
Flooring
Marble(By Others)
Ceiling
Wall
ENTRANCE
ENTRANCE
Door
Jamb
Hall Button
Indicator
PASSENGER ELEVATORS13
03Design Collection
REAR VIEW
DESIGN
COLLECTION
DESIGN
COLLECTION
FRONT VIEW
CAGE DESIGN
Ceiling
Wall
REAR VIEW
ENTRANCE
ENTRANCE
FRONT VIEW
CAGE DESIGN
Door
Jamb
Hall Button
Indicator
Ceiling
Wall
ENTRANCE
Door
Stainless Hairline(#4)
Air-Sterilization System
Jamb
Hall Button
Indicator
Handrail
Handrail
FL / Stainless Hairline(#4)
Car Doors
Car Doors
Stainless Hairline(#4)
Operating Panel
Operating Panel
Car Lantern
Car Lantern
Flooring
Marble(By Others)
Flooring
Marble(By Others)
ENTRANCE
PASSENGER ELEVATORS15
03Design Collection
REAR VIEW
DESIGN
COLLECTION
Ceiling
CD219A
CD251A
Painted Steel(P022),
Acrylic, Convective Air Sterilization System
REAR VIEW
CD299B
CD329B
Handrail
FRONT VIEW
CAGE DESIGN
Ceiling
Wall
ENTRANCE
ENTRANCE
Door
Stainless 2B Vibration
LED Downlight
Jamb
Hall Button
Indicator
Handrail
Car Doors
Stainless 2B Vibration
Operating Panel
Car Lantern
Flooring
Marble(By Others)
1E (1 Pipe Stainless)
PASSENGER ELEVATORS17
Signal Fixtures
Operating Panels
Hall Buttons
No Smoking
HPBU- 230B
HPBU- 230BK
03 Signal Fixtures
HPIU-D310
FIREFIGHTER'S
SERVICE
Firefighter's Cabinet
ANSI 2004 / 05 / 07
Hall Lantern
OFF
H
I
G
H
L
O
W
FAN
O
N
O
N
PHOTOEYE
OFF
ACCESS
Function Switch
OFF
H
I
G
H
L
O
W
H
I
G
H
L
O
W
FAN
FAN
11
11
12
12
10
10
Car Lantern
OFF
OFF
OFF
O
N
LIGHT
DOOR
OPEN
DOOR
CLOSE
ALARM
Push Button
STOP
U
N
S
T
O
P
HELP
HLSU- 640R
HELP
HELP
WHEN FLASHING
HELP IS ON WAY
NO SMOKING
CAPACITY 2500 LBS
ELEV NO. 01
HLSU- 640T
CLSU- 640R
CLSU- 640T
Call Button
No Smoking,
Capacity and Elevator Number
MAIN
Painted Steel
SUB
(Optional)
Note : At least one 'No Smoking' sign is required. Two or more 'No Smoking' sign is optional.
P022 (Black)
P023
PASSENGER ELEVATORS19
Items
Descriptions
Marks
1) Selective collective
The first call determines the direction of the elevator. All calls opposing the respective
direction are serviced after carrying out by the calls of the respective direction.
2) Duplex selective
collective
2 units of elevator provide the effective service for the common hall calls.
3) Automatic bypass
When a car is 80% loaded, it will automatically bypass all hall calls as the bypass load
weighing device is activated.
4) Arrival Voice
5) Signal fixtures
6) Single-side safety
edge of door
7) Ventilation fan
Contact with a passenger or inanimate object causes the doors to stop and
reopen automatically.
The elevator doesnt start if the door is not completely closed.
Items
Descriptions
Marks
During the operation if the car stops between floors, and safety device doesnt work,
the car automatically moves to the nearest floor with the low speed. Then, it opens the
door to allow the passengers to exit off.
Multi-beam from the top to the bottom of the door senses any obstruction caught in the
door. It makes the door reopen and stay open until the obstruction is removed.
When a fire breaks out, all cars activated by the switch or fire detector are immediately
called to a specified rescue floor for the passengers safety.
15) Anti-nuisance
Evaluates the number of people on the car and compares that value to the number of the
car calls registered. If the number of car calls exceeds the number of people in the car by
the load sensor, the car call exceeding the number of passengers will be cancelled after
service nearest call only.
When the firemans switch located at the main floor lobby and operating panel on the
car is activated during a fire or other emergency, a designated car can be called back to a
specified floor for fire fighting service.
This system has various functions, like elevator monitoring and control by a personal
computer and modem.
In case of a power failure, it automatically turns on the emergency light in the car.
9) Automatic interruption of
light and ventilation fan
The lights and ventilation fan are automatically turned off to save energy if there is
no call registered for a period of time. If there is a call registered again, it works again.
It is activated when the attendant turns on the ATT switch in the car operating panel to
tONu position.
When the door is opened, the switch installed at the door operator is activated and
keeps the car from moving. During the operation of car, it locks the door completely so as
not to open the door from out side.
When the seismic sensor detects and earthquake that exceeds a predetermined level,
all cars promptly proceed to land at the nearest floor and park with the doors open to
allow passengers to exit out safely.
To protect the overload of an elevator, this device sounds a buzzer and the elevator
remains stopped at that floor when the number of passengers exceeds the rated
capacity. When the excess number of passengers get out of the car, the buzzer stops
and the elevator door closes.
21) Parking
With the use of the parking switch on the hall button, the car can be parked at a
specified floor, during nights and holidays.
PASSENGER ELEVATORS21
150~350fpm [45~105m/min]
Plan of Hoistway
Section of Hoistway
Standard Dimensions
Trolley beam
(By others)
Unit : feet-inch(mm)
X
Min.2'-10" (863)
Clear Opening
7' (2134)
Overhead(OH)
Min.5'-9" (1753)
Rated Speed
fpm (mpm)
X
X1
Double Door
Min.5'-41/8" (1628)
Control
Panel
1'-21/4" (362)
Min.5'(1524)
Minimum Control
Space Requirements
For One Car
150/200 (45/60)
350 (105)
R2
3' (914)
Minimum Control
Room Requirements
For One Car
(W)3'x(H)7'
M/C Room Entrance
(By others)
X2
4" (102)
Section X-X
X1
Control
Panel
CB
JJ
3' (914)
X1
4" (102)
5'-8"
(1727)
X2
(mm)
X3
(mm)
7'-7"
(2311)
15'-61/16"
(4726)
23'-51/ 8"
(7141)
2500
(1134)
3'-6"
(1067)
3000
(1361)
3'-6"
(1067)
3500
(1588)
3'-6"
(1067)
6'-8"
(2032)
4'-9"
(1448)
8'-7"
(2616)
17'-6"
(5334)
26'-5"
(8052)
5'-5"
(1651)
Y (SO)
(mm)
Y (CO)
(mm)
6'-6"
(1981)
6'-7"
(2007)
7'-0"
(2134)
7'-1"
(2159)
7'-8"
(2337)
7'-9"
(2362)
Unit : feet-inch(mm)
Inspection Ladder
By others
150/200 (45/60)
X1
350 (105)
150/200 (45/60)
Control
Panel
CA
Control
Panel
CA
CB
3'-0"
(914)
X1
(mm)
Depth
350 (105)
150/200 (45/60)
350 (105)
Minimum Control
Room Requirements
For Three Car
CO:
Center Open
350 (105)
350 (105)
Min.8'-4" (2540)
Control
Panel
JJ
SS:
Single Slide
JJ
Capacity
JJ
3' (914)
(W)3'x(H)7'
M/C Room Entrance
(By others)
Overhead
Pit
Pit Reaction
Reaction Force (kN)
Lbs (kg)
CAR
X3
CA
2100
(953)
CB
(mm)
3 Cars
4'-3"
(1295)
150/200 (45/60)
150/200 (45/60)
4" (102)
CA
(mm)
2 Cars
Inspection Receptacle
By others
CWT
(W)3'x(H)7'
M/C Room Entrance
(By others)
Minimum Control
Room Requirements
For Two Car
X1
OP
(mm)
1 Car
CA
JJ
Lbs
(kg)
Min.7' (2134)
Control
Panel
CA
350 (105)
JJ
Control
Panel
Travel (TR)
Minimum Height
7'-6" (2286)
R3
R4
X1
150/200 (45/60)
Control
Panel
CB
CA
SS:
Single Slide
350 (105)
Varies
Clear
Opening
Door Type
150/200 (45/60)
R1
Capacity
2100
(953)
2500
(1134)
3000
(1361)
3500
(1588)
OH (mm)
PP (mm)
CAR (kN)
CWT (kN)
13'-9" (4191)
5'-0" (1524)
71
57
14'-6" (4420)
5'-5" (1651)
91
73
13'-9" (4191)
5'-0" (1524)
81
64
14'-6" (4420)
5'-5" (1651)
104
82
13'-9" (4191)
5'-0" (1524)
90
70
14'-6" (4420)
5'-5" (1651)
115
89
86
65
14'-6" (4420)
127
96
5'-7" (1702)
R1
R2
R3
R4
Trolley1 (TM)
Trolley2 (CAR)
65
65
14
24
20
66
70
70
15
26
20
72
76
76
16
27
20
79
78
78
17
29
20
84
Notes : 1. If occupied spaced exists below the hoistway, Consult Hyundai Sales Engineer.
2. All dimensions are based on 8- 0 cage with 7'-0" entrance door height.
3. Higher car height may affect overhead(OH) dimension.
4. For seismic zones, add 1 (26mm) to dimension X1.
5. When selecting the trolley beam, safety factor needs to be at least level 4.
PASSENGER ELEVATORS23
Section of Hoistway
Standard Dimensions
Unit : feet-inch(mm)
MX1
Capacity
Rated Speed
fpm (mpm)
"A"
MY
RB
CA
CB
RA
X1
JJ
350 (105)
150/200 (45/60)
350 (105)
Clear Opening
7' (2134)
MX2
X2
X1
CA
JJ
JJ
350 (105)
CB
CA
150/200 (45/60)
MY
4" (102)
Control
Panel
150/200 (45/60)
350 (105)
X1
4" (102)
CA
CB
CA
JJ
Control
Panel
(W)3' x (H)7'
M/C Room Entrance
(By others)
Inspection Receptacle
(By others)
JJ
Control
Panel
Control
Panel
JJ
3000
(1361)
3500
(1588)
4000
(1814)
3'-0"
(914)
5'-8"
(1727)
CB
(mm)
3 Cars
X1
(mm)
X2
(mm)
X3
(mm)
8'-31/ 2"
(2527)
16'-11"
(5156)
25'-61/ 2"
(7785)
CO:
Center
Open
CO:
Center
Open
(2832)
3'-6"
(1067)
6'-8"
(2032)
18'-11"
(5766)
7'-8"
(2337)
20'-11"
(6376)
3 Cars
Depth
MX1
(mm)
MX2
(mm)
MX3
(mm)
Y
(mm)
9'-31/ 2"
(2832)
18'-11"
(5766)
27'-61/ 2"
(8395)
20'-11"
(6376)
30'-61/ 2"
10'-6"
(3200)
(3137)
(9309)
6'-11/4"
(1860)
28'-61/ 2"
(8700)
11'-0"
(3353)
10'-31/ 2"
(3137)
6'-8"
(2032)
10'-31/ 2"
(3137)
2 Cars
5'-73 /16"
(1707)
(8700)
5'-5"
(1651)
1 Car
10'-31/ 2"
6'-0"
(1829)
18'-11"
(5766)
Y (CO)
(mm)
28'-61/ 2"
4'-9"
(1448)
9'-31/ 2"
(2832)
4'-0"
(1219)
Y (SO)
(mm)
5'-6"
(1676)
4'-3"
(1295)
9'-31/ 2"
SS:
Single
Slide
Depth
20'-11"
(6376)
30'-61/ 2"
(9309)
6'-9 1/4"
(2063)
31'-61/ 2"
(9614)
11'-8"
(3556)
11'-31/ 2"
( 3442)
22'-11"
(6985)
33'-61/ 2"
(10224)
Capacity
Overhead
Pit
Lbs (kg)
OH (mm)
PP (mm)
CAR (kN)
CWT (kN)
14'-1" (4293)
5'-3" (1600)
70
56
14'-7" (4445)
5'-6" (1676)
90
72
14'-1" (4293)
5'-3" (1600)
82
65
14'-7" (4445)
5'-6" (1676)
104
83
14'-1" (4293)
5'-3" (1600)
91
70
14'-7" (4445)
5'-6" (1676)
116
90
14'-1" (4293)
5'-3" (1600)
86
65
14'-7" (4445)
5'-6" (1676)
127
97
14'-1" (4293)
5'-3" (1600)
95
72
14'-7" (4445)
5'-6" (1676)
141
106
2100
(953)
Pit Reaction
RB (kN)
58
105
60
113
66
122
70
129
73
138
X1
150/200 (45/60)
CA
2500
(1134)
CA
(mm)
2 Cars
Unit : feet-inch(mm)
X3
4" (102)
SS:
Single
Slide
2100
(953)
OP
(mm)
1 Car
Rated speed
fpm (mpm)
MX3
X1
Lbs
(kg)
Travel (TR)
Control
Panel
(W)3' x (H)7'
M/C Room Entrance
(By others)
150/200 (45/60)
150/200 (45/60)
Overhead (OH)
X1
350 (105)
350 (105)
Control
Panel
(W)3' x (H)7'
M/C Room Entrance
(By others)
150/200 (45/60)
Door
Type
CWT
CAR
Inspection Ladder
(By others)
Cinder Concrete &
Water Proofed Finish
(By others)
350 (105)
150/200 (45/60)
350 (105)
150/200 (45/60)
350 (105)
150/200 (45/60)
350 (105)
2500
(1134)
3000
(1361)
3500
(1588)
4000
(1814)
Notes : 1. If occupied spaced exists below the hoistway, Consult Hyundai Sales Engineer.
2. All dimensions are based on 80 cage with 7'-0" entrance door height.
3. Higher cage Height may affect overhead(OH) dimension.
4. For seismic zones, add 2"(51mm) to dimension X1.
5. Max. Travel is 75m.
PASSENGER ELEVATORS25
Jamb
depth
Wall
Thickness
Jamb
depth
Wall
Thickness
AJP150
43 /4" (121)
39 /16" (90)
Wall
Thickness
13 /16" (30)
4"
(102)
AJP150S
Clear Opening
JJ
6"
(152)
6"
(152)
Clear Opening
JJ
Finished wall
(By Others)
13 /16" (30)
6"
(152)
Clear Opening
JJ
6"
(152)
Finished Wall
4"
(102)
Jamb
depth
O
N
Jamb
depth
A
A
BYPASS
Clear Opening
JJ
OFF
FIREMAN
Concrete Opening
HH+4"
Clear Opening
HH
O
N
Clear Opening
HH (Std : 7' (2134))
BYPASS
OFF
Concrete Opening
HH+4"
Clear Opening
HH
4"
(102)
Finished Wall
FIREMAN
Finished wall
(By Others)
Clear Opening
HH (Std : 7' (2134))
Finish
Thickness
13 /16" (30)
Finish
Thickness
Finished Floor
(By Others)
Finished wall
(By Others)
4"
(102)
43 /4" (121)
Finished wall
(By Others)
39 /16" (90)
4"
(102)
Jamb
depth
Clear Opening
JJ
Jamb
depth
4"
(102)
AJP150S
Wall
Thickness
Finish
Thickness
13 /16" (30)
Finish
Thickness
AJP150
Finished Floor
(By Others)
39 /16" (90)
Finished Floor
(By Others)
Clear Opening
JJ
Finished Floor
(By Others)
43 /4" (121)
PASSENGER ELEVATORS27
Hoistway
2100
2500
3000
3500
Rated Speed
fpm (mpm)
1 Car
Motor
(kw)
MCCB
(A)
2 Cars
Power Supply
(KVA)
FLU (A)
FLAcc (A)
FLU (A)
FLAcc (A)
1 Car
2 Cars
1 Car
2 Cars
150/200 (45/60)
5.9
11.5
23.0
23.0
46.0
20
30
11
300(90)
8.8
20.0
40.0
40.0
80.0
20
40
17
350(105)
10.3
20.0
40.0
40.0
80.0
30
50
11
19
on the Hyundai layout not to exceed -0/+1 (25mm) and not less
150/200 (45/60)
7.0
13.5
27.0
27.0
54.0
20
30
13
300(90)
10.5
23.5
47.0
47.0
94.0
30
50
11
20
350(105)
12.2
23.5
47.0
47.0
94.0
30
50
13
23
150/200 (45/60)
8.4
17.5
35.0
35.0
70.0
20
40
16
300(90)
12.5
27.0
54.0
54.0
108.0
30
50
13
24
5. Provide electrical power for lights, tools, welding, and hoisting, etc.
350(105)
14.6
27.0
54.0
54.0
108.0
30
60
15
28
6. Provide one dedicated outside phone line per elevator. And it shall be
150/200 (45/60)
9.9
20.0
40.0
40.0
80.0
30
50
10
19
300(90)
14.8
31.0
62.0
62.0
124.0
30
60
16
28
350(105)
17.3
31.0
62.0
62.0
124.0
40
70
18
33
Smoke Detectors
1. Provide smoke detectors, location as required, with wiring from the
minimum requirements.
by others.
3. Provide a freestanding removable barricade at each hoistway
opening at each floor.
Capacity
(Lbs)
2100
2500
3000
3500
4000
1 Car
MCCB
(A)
2 Cars
Power Supply
(KVA)
Rated Speed
fpm (mpm)
Motor
(kw)
FLU (A)
FLAcc (A)
FLU (A)
FLAcc (A)
1 Car
2 Cars
1 Car
2 Cars
150/200 (45/60)
5.9
11.5
23.0
23.0
46.0
20
30
11
Pit
1. Pit floor must be designed to sustain vertical forces on car and
counterweight rails and impact loads on car and counterweight
300(90)
8.8
20.0
40.0
40.0
80.0
20
40
17
350(105)
10.3
20.0
40.0
40.0
80.0
30
50
11
19
150/200 (45/60)
7.0
13.5
28.0
27.0
56.0
20
30
13
300(90)
10.5
23.5
48.0
47.0
96.0
30
50
11
20
350(105)
12.2
23.5
48.0
47.0
96.0
30
50
13
23
150/200 (45/60)
8.4
17.0
35.0
34.0
70.0
20
40
16
300(90)
12.5
27.0
55.0
54.0
110.0
30
50
13
24
performance.
350(105)
14.6
27.0
55.0
54.0
110.0
30
60
15
28
150/200 (45/60)
9.9
19.5
40.0
39.0
80.0
30
50
10
19
300(90)
14.8
32.0
64.0
64.0
128.0
30
60
16
28
350(105)
17.3
32.0
64.0
64.0
128.0
40
70
18
33
150/200 (45/60)
11.3
22.0
45.0
44.0
90.0
30
50
12
21
300(90)
16.9
36.0
72.0
72.0
144.0
40
70
18
32
350(105)
19.8
36.0
72.0
72.0
144.0
40
70
21
38
Note : The values in the table above are based on 3 phase 480V.
FLU : Full load up current
FLAcc : Full load accelerating current
Electrical
1. Power Conditions
1) Three phase: Provide a permanent three phase electrical feeder
with separate grounding conductor terminating in controller either
at the top landing or landing below before the start of the
PASSENGER ELEVATORS29