Escolar Documentos
Profissional Documentos
Cultura Documentos
Insulation zone
Guidance on thermal
continuity
Red text
Guidance on air
tightness
Rigid insulation /
plasterboard composite
0.21
0.04
0.13
0.77
0.044
1.13
Concrete block
(lightweight, high strength)
0.19
Timber frame
Concrete floor beam
Concrete screed
Render (cement/sand)
Gypsum plaster
(1000kg/m3)
0.13
2.3
1.15
1.0
0.4
1.5
0.25
0.13
0.13
0.13
0.13
160
50
17
1
0.23
0.022
Timber batten /
service void (option)
Vapour control layer
Insulation
Sheathing board
Breather membrane
Wall ties
Cavity
Psi-value calculations
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Isometric cut-away view
Detail 3.00
Design advice
Minimising condensation risk
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Psi value = 0.0464W/mK Pitched Roof: Ventilated Roofspace - Eaves
Detail 3.01
Design advice
Minimising condensation risk
Cavity ventilator
Vapour control layer in
wall and ceiling
Insulation between the
studs must be tightly fitted
leaving no gaps
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Psi value = 0.1006W/mK Pitched Roof: Ventilated Roofspace - Gable
Detail 3.02
Masonry built up
between ladder legs
Cavity ventilator
Design advice
Cavity barrier giving 30
minute fire resistance ensure cavity barrier is not
breeched by inappropriate
rigid sheathing insulation
material
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Psi value = 0.0472W/mK Pitched Roof: Ventilated Rafter Void - Gable
Detail 3.03
Design advice
Minimising condensation risk
1. Check ventilation paths are clear before
installing insulation above the ceiling
Thermal Resistance of insulation used in
details:
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Psi value = 0.0284W/mK Pitched Roof: Ventilated Batten Void (warm roof) - Eaves
Detail 3.04
Vapour
permeable
membrane
(with a vapour
resistance of
not more than
0.25 MN.s/g)
Design advice
Minimising condensation risk
Compressible filler
Cavity ventilator
Cavity barrier giving 30
minute fire resistance ensure cavity barrier is not
breeched by inappropriate
rigid sheathing insulation
material
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Psi value = 0.0431W/mK Pitched Roof: Ventilated Batten Void (warm roof) - Gable
Detail 3.05
Design advice
Vapour control layer in ceiling
Compressible filler
Cavity ventilator
Cavity barrier giving 30
minute fire resistance ensure cavity barrier is not
breeched by inappropriate
rigid sheathing insulation
material
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Psi value = 0.0536W/mK Timber Flat Roof
Detail 3.06
Design advice
Minimising condensation risk
Cavity barrier
giving 30 minute
fire resistance ensure cavity
barrier is not
breeched by
inappropriate rigid
sheathing
insulation material
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Psi value = 0.0299W/mK Timber Flat Roof with Parapet
Detail 3.07
30 minute fire
resisting
proprietary
insulating cavity
barrier with
integral DPC
Design advice
Minimising condensation risk
1. Alternative internal finish at window
reveal - use insulation backed
plasterboard
Compressible fill
Weep Hole
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Lintel at Window Head
Detail 3.08
Jamb detail
Compressible
filler between
window and cill
Solid cill acts as cavity
closer. If pressed cill is
used, a 30 minute fire
rated thermally insulated
cavity closer will be
requied
Design advice
Air tightness tape and
sealant to back of frame
Insulate the window reveal
DPC lapped
behind cill and
below window
Vapour control
layer in wall
Insulation between the
studs must be tightly
fitted leaving no gaps
Cill detail
HEAT 2.7 software image of isotherms
through junction detail.
For illustrative purposes only.
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Windows and Doors - Jambs and Cills
Detail 3.09
Design advice
Minimising condensation risk
Damp proof membrane
above or below slab
20mm strip of perimeter
insulation with thermal
conductivity ( value) not
exceeding 0.025 W/mK around
slab and any screed
Alternative detail
3. Using lightweight blockwork (e.g. with
value of 0.19W/mK) to improve the
thermal performance at the junction where
the external wall and ground floor
constructions meet will change the psi
value
Thermal Resistance of insulation used in
details:
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Psi value = 0.1145W/mK Ground Bearing Floor: Insulation Above Slab
Detail 3.10
Design advice
Minimising condensation risk
Damp proof membrane
50mm strip of perimeter
insulation with thermal
conductivity ( value) not
exceeding 0.025 W/mK around
slab and any screed
Alternative detail
2. Using lightweight blockwork (e.g. with
value of 0.19W/mK) to improve the
thermal performance at the junction
where the external wall and ground floor
constructions meet will change the psi
value
Thermal Resistance of insulation used in
details:
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Psi value = 0.1733W/mK Ground Bearing Floor: Insulation Below Slab
Detail 3.11
Solum
Design advice
Minimising condensation risk
1. Check that all ventilation paths are clear
before installing the floor insulation
Sub floor ventilation should be
per run of external wall or
Alternative detail
2. Using lightweight blockwork (e.g.
with value of 0.19W/mK) to improve
thermal performance at the junction
where the external wall and ground floor
constructions meet will change the psi
value
3. If there are concerns about damaging the
air tightness membrane in the floor finish
during construction, an additional services
void can be created using timber battens
on top of the floor joists
Thermal Resistance of insulation used in
details:
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Psi value = 0.0423W/mK Timber Suspended Ground Floor
Detail 3.12
Design advice
Minimising condensation risk
1. Check that insulation is fitted between
timber studs at corner junctions
Thermal Resistance of insulation used in
details:
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Psi value = 0.0725W/mK Separating Wall
Detail 3.13
Cavity
ventilator
Cavity barrier
giving 30 minute
fire resistance ensure cavity
barrier is not
breeched by
inappropriate rigid
sheathing
insulation material
Design advice
Vapour control layer in wall
Insulation between the studs must be
tightly fitted leaving no gaps
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Psi value = 0.0353W/mK Timber Separating Floor
Detail 3.14
Design advice
Vapour control layer in wall
Insulation between the
studs must be tightly
fitted, leaving no gaps
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Psi value = 0.0574W/mK Intermediate Floor / External Wall
Detail 3.15
Solum
Design advice
Minimising condensation risk
Sub floor ventilation should be
per run of external wall or
Alternative Detail
2. Lightweight thermal blockwork can be
used in the separating wall to improve the
thermal performance but this will also
reduce the acoustic performance of the
wall. If this alternative is used then
additional elements will be required to
meet Section 5 of the Technical
Standards.
Thermal Resistance of insulation used in
details:
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Psi value = 0.0713W/mK Ground Floor/Separating Wall Junction- timber suspended floor Detail 3.16
Design advice
Minimising condensation risk
1. If a screed finish is used instead of a
timber floor, use a strip of perimeter
insulation with a minimum R value of
Damp proof membrane
Lightweight loadbearing concrete
blockwork to minimise thermal bridging
Alternative Detail
2. Heavyweight thermal blockwork can be
used in the separating wall below slab
level but this will reduce the thermal
performance of this junction. Additional
construction elements may be required
along with lightweight blockwork in order
to meet the acoustic requirements of
Section 5 of the the Technical Standards
Thermal Resistance of insulation used in
details:
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Psi value = 0.2765W/mK Concrete Ground Floor/ Separating Wall: Insulation Below Slab Detail 3.17
Design advice
Minimising condensation risk
Damp proof membrane
Alternative Detail
3. Lightweight thermal blockwork can be
used in the separating wall to improve the
thermal performance but this will also
reduce the acoustic performance of the
wall. If this alternative is used then
additional elements will be required to
meet Section 5 of the Technical
Standards.
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Psi value = 0.0146W/mK Concrete Ground Floor/ Separating Wall: Insulation Above Slab Detail 3.18
Cavity barrier
Design advice
Vapour control layer in ceiling
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Psi value = 0.0241W/mK Separating Floor / Wall Junction
Detail 3.19
Cavity barrier
Design advice
Install air tightness barrier around
joists, then lap membrane from
walls over it and tape junction
Vapour control layer in wall
Insulation between the studs
must be tightly fitted
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Psi value = 0.0333W/mK Intermediate Floor
Detail 3.20
Design advice
Minimising condensation risk
1. Check ventilation paths are clear before
installing insulation above the ceiling
Thermal Resistance of insulation used in
details:
Cavity barrier is used in line with
ceiling insulation to prevent thermal
bypass.Use dense insulation or
proprietary cavity barrier in sleeve
Separating walls require
additional layers and components
to comply with Section 2: Fire
and Section 5: Noise
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Psi value = 0.0132W/mK Pitched Roof: Cold Roof / Separating Wall junction
Detail 3.21
Design advice
Minimising condensation risk
1. Check ventilation paths are clear before
installing insulation above the ceiling
Thermal Resistance of insulation used in
details:
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Psi value = 0.0481W/mK Pitched Roof: Ventilated Batten Void / Separating Wall Junction Detail 3.22
Insulation between
the studs must be
tightly fitted leaving
no gaps
Design advice
Minimising condensation risk
Vapour control
layer
Plan view
This example should be read in conjunction with the guidance in the introduction to this document. It illustrates the reduction
of unwanted infiltration in buildings and provides a Psi value for this junction situation which can be used in calculation
provided the principles outlined and any identified component specification are followed.
Timber Frame
Psi value = 0.0179W/mK Wall Junction
Detail 3.23