Laboratory

Metal Lab, New No. 4, Old No. 128/3, East Vannier Street, IInd Floor,
West K.K. Nagar, Chennai, Tamil Nadu

Accreditation Standard

ISO/IEC 17025: 2005

Discipline
Certificate Number
Last Amended on

Non-Destructive Testing
T-2387
-

S.No. Product /
Material of Test

Specific Test Performed

Issue Date
Valid Until
Page

19.12.2014
18.12.2016
1 of 3

Test Method Specification


against which tests are
performed

Range of Testing /
Limits of Detection

ASME Sec V Article 4 : 2013


ASME SE 164 : 1997
ASME SE 273 : 2013

5 mm to 100 mm thick steel


Sensitivity: /2

AT LABORATORY AND AT SITE


I.
1.

METAL AND ALLOYS


Weld Joints

Ultrasonic Testing

BS EN 1712 : 1997
BS EN 1713 : 1998
BS EN 1714 : 1998
BS EN 583 : 1 1999
BS EN 583 : 2 2001
BS EN 583 : 3 1997
BS EN 583 : 4 2002
BS EN 583 : 5 2001
IS 4260: 2004
2.

Castings

Ultrasonic Testing

ASME Sec. V Article 5 : 2013


ASME SA 609/SA 609M 2013

Thick Steel: 15 mm to 300 mm


Sensitivity: /2

3.

Steel Plates

Ultrasonic Testing

ASME Sec. V Article 5 : 2013


ASME SA 435/ SA 435M
(RA 2007)
ASME SA 578/ SA 578
MS 2007

Thick Steel: 8 mm to 300 mm


Sensitivity: /2

4.

Forgings

Ultrasonic Testing

ASME Sec. V Article 23 : 2013


ASME SA 388/SA388M 2011
ASME SA 745/SA 745M

Thick Steel: 10 mm to 500 mm


Sensitivity: /2

Prachi Kukreti
Convenor

N. Venkateswaran
Program Manager

Laboratory

Metal Lab, New No. 4, Old No. 128/3, East Vannier Street, IInd Floor,
West K.K. Nagar, Chennai, Tamil Nadu

Accreditation Standard

ISO/IEC 17025: 2005

Discipline
Certificate Number
Last Amended on

Non-Destructive Testing
T-2387
-

S.No. Product /
Material of Test

Specific Test Performed

Test Method Specification


against which tests are
performed

Issue Date
Valid Until
Page

19.12.2014
18.12.2016
2 of 3

Range of Testing /
Limits of Detection

(RA 2009)
5.

Aluminum Alloy
Plate

Ultrasonic Testing

ASME Sec. V Article 5 : 2013


ASME SB 548 2009

Thick Aluminum: 10 mm to
300 mm
Sensitivity: /2

6.

Pipe and Tubing

Ultrasonic Testing

ASME Sec. V Article 5 : 2013


ASME SE 213 2009

Thick Steel: 8 mm to 30 mm
Sensitivity: /2

7.

Welded Pipe &


Tubing

Ultrasonic Testing

ASME Sec. V Article 5 : 2013


ASME SE 273 2010

Thick Steel: 8 mm to 30 mm
Sensitivity: /2

8.

Weld Joints
Ferro Magnetic

Magnetic Particle Testing


(Yoke)

ASME Sec. V Article 7 : 2013


ASME SE 709 2008

Surface defect &


Sub-surface defect

BS EN 1290 : 1998
BS EN 1291 : 1999
BS EN ISO 3059 : 2001

(Upto 3 mm depth)

9.

Castings Ferro
Magnetic

Magnetic Particle Testing


(Yoke)

ASME Sec. V Article 7 : 2013


ASME SE 709 2008

Surface defect &


Sub-surface defect
(Upto 3 mm depth)

10.

Forgings Ferro
Magnetic

Magnetic Particle Testing


(Yoke)

ASME Sec. V Article 7 : 2013


ASME SE 709 2008

Surface defect &


Sub-surface defect
(Upto 3 mm depth)

11.

Weld Joints

Liquid Penetrant testing

ASME Sec. V Article 6 : 2013


ASME SE 165 2009
BS EN 1289 : 1998

Defects open to surface

12.

Castings

Liquid Penetrant testing

ASME Sec. V Article 6 : 2013

Defects open to surface

Prachi Kukreti
Convenor

N. Venkateswaran
Program Manager

Laboratory

Metal Lab, New No. 4, Old No. 128/3, East Vannier Street, IInd Floor,
West K.K. Nagar, Chennai, Tamil Nadu

Accreditation Standard

ISO/IEC 17025: 2005

Discipline
Certificate Number
Last Amended on

Non-Destructive Testing
T-2387
-

S.No. Product /
Material of Test

Specific Test Performed

Test Method Specification


against which tests are
performed

Issue Date
Valid Until
Page

19.12.2014
18.12.2016
3 of 3

Range of Testing /
Limits of Detection

ASME SE 165 2009


13.

Forgings

Liquid Penetrant testing

ASME Sec. V Article 6 : 2013


ASME SE 165 2009

Defects open to surface

14.

Ferrous &
Non Ferrous
Materials

Ultrasonic Thickness
Measurements

ASME Sec. V : 2013


ASME SE 797 2010

Thick Steel: 2 mm to 200 mm

-X-X-X-X-X-X-X-X-X-X-X-X-X-X-

Prachi Kukreti
Convenor

N. Venkateswaran