Você está na página 1de 6

www.hilti.co.

th/holth
Company:
Specifier:
Address:
Phone | Fax:
E-Mail:

Hilti PROFIS Rebar 2.4.0

FOTHELO

Page:
Project:
Fastening point:
Date:

1
ANCHOR SUITES SIGNAGE
Node no 11
15/07/2015

Specifiers comments:

Design standard:

EC2 / ETA

Application type:

Standard applications/Column extension

1. Loads
Loads
Md
Md,xz

3. Material & Safety

Drilling

Structure

0.00 kNm

Hole condition

Dry

Concrete class (existing structure)

C20/25

0.00 kNm

Drilling method

Hammer drilling

Char. yield strength (existing)

500 N/mm

Drilling aid

Drilling aid is used

Char. yield strength (new)

500 N/mm

Nd

140 kN

Highest

17.5 kN/bar

Lowest

17.5 kN/bar

Fire design
Fire rating

2. Drilling & Temperature

Temperature (EC2/ETA)
During installation

from 5 C to 40 C

During service

20 C / 20 C

None

Fatigue design
None
Seismic
Seismic loads

No

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.co.th/holth
Company:
Specifier:
Address:
Phone | Fax:
E-Mail:

Hilti PROFIS Rebar 2.4.0

FOTHELO

Page:
Project:
Fastening point:
Date:

2
ANCHOR SUITES SIGNAGE
Node no 11
15/07/2015

4. Eurocode 2 parameters

5. Existing reinforcement

6. Post-installed reinforcement

cc

1.00

Longitudinal reinforcement

Reinforcements parameters

ct

1.00

Bar size

16.0 mm

Diameter

25.0 mm

Concrete cover

40.0 mm

Spacing - Y

162 mm

Number of bars

4x4

Spacing - X

162 mm

25.0 mm

ct,bond

1.00

ud

0.0200

k2

0.850

Bar size

10.0 mm

cd (EC2, 8.4.4.1)

68.8 mm

'

0.920

Concrete cover

40.0 mm

Bond conditions

Good

max

0.0400

Spacing

250 mm

Min. reinforcement

100 mm/m

c2

2.0010-3

Parameters

c2u

3.5010-3

0.700

Transverse pressure

0.00 N/mm

0.700

Cover of tension force line b

0.00 mm

Bond conditions

Good

Transverse reinforcement

Other

Concrete cover to face


Concrete cover to face

30.0 mm

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.co.th/holth
Company:
Specifier:
Address:
Phone | Fax:
E-Mail:

Hilti PROFIS Rebar 2.4.0

FOTHELO

Page:
Project:
Fastening point:
Date:

3
ANCHOR SUITES SIGNAGE
Node no 11
15/07/2015

Selected solution
Bar size

Drill bit size

Bar spacing - Y
centre/centre

Bar spacing - X
centre/centre

Distance
centre/surface

Drilled hole
required

Anchorage for
yield of bar

[mm]

D [mm]

s [mm]

s [mm]

cs [mm]

vreq [mm]

vy [mm]

25.0

32.0

163

163

238

577

1,353

Bar with
highest load

Required accessories
Drilling

Cleaning

Setting

- Suitable rotary hammer


- Properly sized drill bit

- Compressed air with required accessories to


blow from the bottom of the hole
- Proper diameter wire brush

- Dispenser including cassette and mixer


- For deep installations, a piston plug is
necessary

Bar with highest load (tension)


Design Input
Design force in bar

FE

17.5 kN

Stress in bars

sd

35.7 N/mm

Adhesive used

Hilti HIT-RE 500

Splice Post-Installed Reinforcement


Bond condition

Good 1

1.00

(input)

Bond strength

fbd,pi

2.30 N/mm

ETA 08/0105

Basic anchorage length

lb,rqd = (/4)(sd/fbd,pi)

96.9 mm

Basic anchorage length (Fyd)

lb,rqd,fyd = (/4)(fyd/fbd,pi)

Factor for splice

1.50

Factor for minimum length

fmult,min

1.00

Minimum splice length

lb,min = fmult,minmax(0.36lb,rqd,fyd; 15; 200 mm)

532 mm

Min of clear cover or half spacing

cd

68.8 mm

Influence cover/spacing

2 = {0.7 1-0.15[(cd-)/] 1.0}

Transverse reinforcement

Ast = t2/4 (1+0.76lb,rqd/st)

110 mm

Min. transverse reinforcement

Ast,min = 2(/4)(sd / fyd)

40.3 mm

K-factor

K = (EN 1992-1-1, table 8.2)

1,181 mm

0.738

0.0500
2

Influence of transv. reinf.

3 = {0.7 1-K(Ast-Ast,min)/( /4) 1.0}

Transverse pressure

0.00 N/mm

Influence of transv. pressure

5 = {0.7 1-0.04p 1.0}

1.00

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

0.993

www.hilti.co.th/holth
Company:
Specifier:
Address:
Phone | Fax:
E-Mail:

Hilti PROFIS Rebar 2.4.0

FOTHELO

Page:
Project:
Fastening point:
Date:

4
ANCHOR SUITES SIGNAGE
Node no 11
15/07/2015

Total influence factor

= {235 0.7}

0.732

Design splice length

l0,pi = max(6lb,rqd; l0,min)

532 mm

Bond condition

Good 1

1.00

Bond strength

fbd,ci

2.32 N/mm

Basic anchorage length

lb,rqd = (/4)(sd/fbd,ci)

100 mm

Basic anchorage length (Fyd)

lb,rqd,fyd = (/4)(fyd/fbd,ci)

749 mm

Factor for splice

1.50

Factor for minimum length

fmult,min

1.00

Minimum splice length

lb,min = fmult,minmax(0.36lb,rqd,fyd; 15; 200 mm)

337 mm

Shape of cast-in bars

Min of clear cover or half spacing

cd

Influence cover/spacing

2 = {0.7 1-0.15[(cd-)/] 1.0}

Transverse reinforcement

Ast = t2/4 (1+0.76lb,rqd/st)

112 mm

Min. transverse reinforcement

Ast,min = 2(/4)(sd / fyd)

65.5 mm

K-factor

K = (EN 1992-1-1, table 8.2)

Splice Cast-in Reinforcement

0.700

40.0 mm
0.775

0.0500
2

Influence of transv. reinf.

3 = {0.7 1-K(Ast-Ast,min)/( /4) 1.0}

0.995

Transverse pressure

0.00 N/mm

Influence of transv. pressure

5 = {0.7 1-0.04p 1.0}

1.00

Total influence factor

= {235 0.7}

Design splice length

l0,ci = max(16lb,rqd; l0,min)

337 mm

Controlling splice length

l0 = max(l0,pi; l0,ci)

532 mm

Clear distance spliced bars

79.8 mm

Increase of splice length

l0,e = max(e-4; 0)

15.8 mm

Front cover

cf

30.0 mm

0.771

Definition of the installation length

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

(input)

www.hilti.co.th/holth
Company:
Specifier:
Address:
Phone | Fax:
E-Mail:

Hilti PROFIS Rebar 2.4.0

FOTHELO

Page:
Project:
Fastening point:
Date:

Installation length

5
ANCHOR SUITES SIGNAGE
Node no 11
15/07/2015

linst = l0 + l0,e + cf

577 mm

Design force in bar

FE

17.5 kN

Stress in bars

sd

35.7 N/mm

Adhesive used

Hilti HIT-RE 500

Bar with lowest load (tension)


Design Input

Splice Post-Installed Reinforcement


Bond condition

Good 1

1.00

(input)

Bond strength

fbd,pi

2.30 N/mm

ETA 08/0105

Basic anchorage length

lb,rqd = (/4)(sd/fbd,pi)

96.9 mm

Basic anchorage length (Fyd)

lb,rqd,fyd = (/4)(fyd/fbd,pi)

Factor for splice

1.50

Factor for minimum length

fmult,min

1.00

Minimum splice length

lb,min = fmult,minmax(0.36lb,rqd,fyd; 15; 200 mm)

532 mm

Min of clear cover or half spacing

cd

68.8 mm

Influence cover/spacing

2 = {0.7 1-0.15[(cd-)/] 1.0}

Transverse reinforcement

Ast = t2/4 (1+0.76lb,rqd/st)


2

1,181 mm

0.738

110 mm

Min. transverse reinforcement

Ast,min = (/4)(sd / fyd)

40.3 mm

K-factor

K = (EN 1992-1-1, table 8.2)

Influence of transv. reinf.

3 = {0.7 1-K(Ast-Ast,min)/(2/4) 1.0}

Transverse pressure

0.00 N/mm

Influence of transv. pressure

5 = {0.7 1-0.04p 1.0}

1.00

Total influence factor

= {235 0.7}

Design splice length

l0,pi = max(6lb,rqd; l0,min)

532 mm

Bond condition

Good 1

1.00

Bond strength

fbd,ci

2.32 N/mm

Basic anchorage length

lb,rqd = (/4)(sd/fbd,ci)

100 mm

0.0500
0.993

0.732

Splice Cast-in Reinforcement

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

(input)

www.hilti.co.th/holth
Company:
Specifier:
Address:
Phone | Fax:
E-Mail:

Hilti PROFIS Rebar 2.4.0

FOTHELO

Page:
Project:
Fastening point:
Date:

6
ANCHOR SUITES SIGNAGE
Node no 11
15/07/2015

Basic anchorage length (Fyd)

lb,rqd,fyd = (/4)(fyd/fbd,ci)

749 mm

Factor for splice

1.50

Factor for minimum length

fmult,min

1.00

Minimum splice length

lb,min = fmult,minmax(0.36lb,rqd,fyd; 15; 200 mm)

Shape of cast-in bars

Min of clear cover or half spacing

cd

Influence cover/spacing

2 = {0.7 1-0.15[(cd-)/] 1.0}

Transverse reinforcement

Ast = t2/4 (1+0.76lb,rqd/st)

337 mm
0.700

40.0 mm

Min. transverse reinforcement

Ast,min = (/4)(sd / fyd)

K-factor

K = (EN 1992-1-1, table 8.2)

0.775

112 mm
65.5 mm
0.0500

Influence of transv. reinf.

3 = {0.7 1-K(Ast-Ast,min)/( /4) 1.0}

0.995

Transverse pressure

0.00 N/mm

Influence of transv. pressure

5 = {0.7 1-0.04p 1.0}

1.00

Total influence factor

= {235 0.7}

Design splice length

l0,ci = max(16lb,rqd; l0,min)

337 mm

Controlling splice length

l0 = max(l0,pi; l0,ci)

532 mm

Clear distance spliced bars

79.8 mm

Increase of splice length

l0,e = max(e-4; 0)

15.8 mm

Front cover

cf

30.0 mm

Installation length

linst = l0 + l0,e + cf

577 mm

0.771

Definition of the installation length

Remarks
This design exclusively considers the local load transfer from the post-installed tensile reinforcement at the intersection between new and existing
concrete. The joint surfaces for concreting must be roughened to at least such an extent that aggregates protrude. It assumes that adequate
transverse reinforcement is provided in the anchorage area if required.
The shear load carrying capacity of the cross section has to be designed separately.
The Installation (drilling, cleaning, setting) must be according to the approval!
Fixed diameter and spacing selected. Please be aware that over-reinforcement of the section may lead to brittle failure of the fastening.
The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to be
followed to ensure a proper installation.
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan