Você está na página 1de 2

TECHNICAL SPECIFICATIONS

NUFLO Gas Turbine Flow Meters


Accurate Gas Flow Measurement
The NUFLO Gas Turbine Flow Meter provides

Designed for maximum life, carbide rotor

accurate gas flow measurement by utilizing a

shaft and bearings require no lubrication. The

lightweight, low inertia rotor to sense gas velocity.

cartridge assembly makes replacement and

Its output frequency has a linear relationship to

inspection of parts easy. The meter is designed

gas velocity over a wide flow range.

for installation between two flanges, and is ideal

The meter tracks the flow rate continuously, offers


little resistance to flow and has a unique cartridge
design that allows removal of all internal parts as
one assembly.

for measurement of fuel gas, production gas,


vent gas and flare gas. The digital pulse output
can be fed to companion readout devices for
direct measurement of flow rate and accumulated
throughput.

The meter exhibits little sensitivity to gas density


above two atmospheres pressure. The low inertia
of the rotor and vee bearings allows overranging
of the meter to twice its rated capacity without
damage for intermittent flow variations.

These measurements can be automatically


compensated for pressure and temperature to
obtain volumetric measurements in standard
units.

Specifications
Size
Flow Range
End Connections
Working Pressure
Test Pressure
Output Frequency
Minimum Output
Voltage
Pressure Drop

Nominal Calibration Factor

2 (50.8 mm)
10:1 to 15:1 (see graph, page 2)
Flow meter installs between two raised
face flanges
0 to 2220 psig (15,306 kPa)
3330 psig (22,960 kPa)
0 to 440 Hz nominal
30 mV peak to peak at 5 Hz

Less than 1 (24.5 mm) water column at


maximum rated flow
Linearity
2% of reading
Repeatability
0.5% of reading
Temperature
0 F to 225 F (-18 C to 107 C)
Pickup Connector
Mates with AN3106A-10SL-4P
Conduit Connection 1 (25.4 mm)
Pressure Tap
1/8 NPT (3.2 mm)
Compliances
CSA Certified Hazardous locations
Class I, Div. 1, Groups A, B, C, D

ANSI 12.27.01 single seal

 ertified by Cameron in compliance with


C
pre-qualified materials of NACE MR0175/
ISO 15156. This certification does not imply
or warrant the application of the product in compliance
with NACE MR0175/ISO 15156 service conditions in
which the customer/user installs the product.

Low Range
Standard Range
High Range

325 p/ACF (11477 p/m3)


125 p/ACF (4415 p/m3)
70 p/ACF (2472 p/m3)

Materials of Construction

Body and Cartridge


Bearing Mounts
Bearings
Rotor
Rotor Shaft
Snap Rings
Set Screws
Pressure Port Plug

Grade 316L stainless steel


Grade 304 stainless steel
Tungsten carbide, vee type
Grade 455 stainless steel, two-bladed
Tungsten carbide
Grade 316 stainless steel
Grade 304 stainless steel
Grade 304 stainless steel

Installation Hardware
All NUFLO gas meters are supplied with universal ANSI Class 150
to Class 600 centering rings and a pickup coil.

Accessories (optional)
Hardware installation kit containing threaded rods, nuts and
gaskets (specify flange rating: ANSI Class 150, 300 or 600)
Conduit pickup extension adapter
Flow conditioners
Meter run sections (specify pressure and flange rating)

Gas Meter Flow Rate

Gas Meter Flow Ranges


MCFD

69,444.4

100,000

1,416,000

34,722.2

50,000

566,400

13,888.9

20,000

283,200

6,944.4

10,000

141,600

3,472.2

5000

56,640

1,388.9

2000

28,320

694.4

1000

14,160

347.2

500

5664

138.9

200

2832

69.4

100

1416

34.7

50

566.4

13.9

20

283.2

6.9

10

141.6

3.5

56.6

1.4

28.3

0.7

LOW

North and South America


14450 JFK Blvd.
Houston, TX 77032
USA
Tel 1.281.582.9500
ms-us@c-a-m.com
Europe, Africa, Caspian and Russia
3 Steyning Way
Southern Cross Trading Estate
Bognor Regis
West Sussex PO22 9TT
England, UK
Tel 44.1243.826741
ms-uk@c-a-m.com
Asia Pacific
Suite 16.02 Menara Am Frst
No. 1 Jalan 19/3
46300 Petaling Jaya
Selangor Darul Ehsan
Malaysia
Tel 603.7954.0145
ms-kl@c-a-m.com

1
(6.9)

2
(13.8)

5
(34.5)

10
(69)

20
(138)

50
(345)

100
200
(690) (1380)

500
(3450)

1000
(6900)

2000
(13800)

FLOWING PRESSURE - PSIG (kPa)


Flow rates are at standard conditions of 14.73 psia and 60 F
and are based on 100% methane gas @ 0.6 s.g.

0.6
G where:

For greater accuracy and additional


performance information, use Cameron's
SizeGas program, available for download from
the Cameron (Measurement Systems) website.

Q (0.6) = ow rate on graph


G
= specic gravity of other gas
Q (g) = ow rate for other gas

Middle East
Level 9, Al Jazira Club Tower A
P.O. Box 47280, Muroor Road
Abu Dhabi
United Arab Emirates
Tel 971.2.596.8400
ms-uk@c-a-m.com
O T H E R L O C AT I O N S

High Range
Standard Range
Low Range

To determine the minimum capacity for other gases use:


Q (g) = Q (0.6)

HIGH

SCFM

2,832,000

L O C AT I O N S

STANDARD

FLOW RATE
3/DAY

ALGERIA
C A N A DA
CHINA
INDIA
M A L AYS I A

Gasket

1.8-in.
(3.2 mm)

10 Nominal Pipe
Diameters
(2-in. diameter pipe)

R U SS I A

Gasket

5 Nominal Pipe
Diameters
(2-in. diameter pipe)
Temperature
Well

UA E
UK
USA
www.c-a-m.com/measurement

INLET
Flow
Conditioner
5 Nominal Pipe
Diameters
(2-in. diameter pipe)

Centering Ring
Gas Turbine Meter
Centering Ring

2012 Cameron | NUFLO is a trademark of Cameron. | Seebridge 12/12 AD00539M

Pressure Tap

Você também pode gostar