Você está na página 1de 41

Alarm System Monitor Centre PH-BC110

User manual

Ver: 6/8/2010

1. System Requirement-------------------------------------------------------------------P04
2. Installation ------------------------------------------------------------------------------------------P04
2.1 Install IIS(very important)----------------------------------------------------------------------P04
2.2 Install Alarm Receiving center-----------------------------------------------------------------P05
2.3 Install Service ------------------------------------------------------------------------------------P05
2.4 Install softdog driver ----------------------------------------------------------------------------P06

2.5 Install Voice Card driver-------------------------------------------------------------------------P06


3. Operations for Software Centre------------------------------------------------------------------P09
3.1 Create/Edit communication protocol ------------------------------------------------------------P09
3.2 Change client(host)) distribution map----------------------------------------------------------P09
3.3 Creat client(host) Information -------------------------------------------------------------------P09
3.4 Configure the host and the detector--------------------------------------------------------------P10
3.5 Software Centre Test -------------------------------------------------------------------------P11
4.Function of the Software ---------------------------------------------------------------------------P13
4.1 Login------------------------------------------------------------------------------------------------P13
4.2 Alarm Center --------------------------------------------------------------------------------P14
4.3 Remote Control and Group Remote Control------------------------------------------------P14
4.4 Alarm Records-------------------------------------------------------------------------------------P16
4.5 Logs-------------------------------------------------------------------------------------------------P16
4.6 Client information--------------------------------------------------------------------------------P17
4.7 System configuration.------------------------------------------------------------------------------P19
4.7.1 Operate Setup
4.7.2 Add the Communication Config
4.7.3 Administrator--------------------------------------------------------------------------------------P19
4.7.4 Create and change the Host Type/ Control Command

7. FAQ-----------------------------------------------------------------------------------------------------P20

Dear users,

Thank you for purchasing our products.


This software is a professional and integrated alarm receiving platform system which adopts SMS
&voice transmission of GSM & telephone network to receive alarm information. It is practically
used on the alarm center where the police are on duty.
There are lots of functions of this alarm system including receiving alarm information, building
user database, receiving SMS and voice, printing alarm details in time etc,. However, this software
neednt professional operation knowledge and professional operator. Its interface is intuitive and
friendly, So it is easy to learn and use.

1. System Requirement
1.1 Operating systemwindows 2000windows XPwindows2003 or above
1.2 Necessary toolsMicrosoft .NET Framework 2.0 or above and Internet Information Services
(IIS)

2.Installation
2.1 Install IIS
Installation package content as below:

Quick installation
Runautorun.exe, Pop-up the window as below

Note: If you already have IIS server, please do not re-install, otherwise it will lead to the existing
site can not run properly.

Check whether the IIS is installed.


Go -Control Panel>> Administrative Tools,
service", and if so, that has IIS installed,
the alarm center", if not, please click on "1.

2.2 install the


alarm center

check whether there is "Internet information


please skip directly to the content 2), install
Install IIS"
After clicking "1. Install IIS" will
installed automatically. If no
prompt error, then no problem to
install alarm center

"2. Install
Note: virtual directory is
AlarmAlarmSystem,
Center"
can be
screen,modified.
click
The default
"Next"website
url:
http://localhost/AlarmSystem
Installing, please
Then Click "Next"

wait...

2.
3

Installation is complete.
Please install the service

Start Service
2.4
Install
softdog
driver
Click
the

Window after clicking "3.


Start Service."Press any key
to continue

"4.Setup SoftDog", you will see this figure


2.5 Install Voice
Card Driver
Click
"5.Setup
VoiceCard",
you
will see this figure
After

installation completed, the web site will automatically open when you close the installation
window.
Hardware installation:
1. GSM receiver module
GSM receiver package

Accessories inside:

Installation:

Insert the SIM card:


USB
to
the

computer
Turn on GSM module, if the
green LED flash which
between two red LED, it

means OK, if not, please check the SIM card and the antenna install properly.

Click "My Computer" "" Properties "" Hardware "" Device Manager "," port (COM and LPT), to
view the module's port number, different ports have different port number. Such as: Prolific USBto-Serial Comm Port (COM9).

Softdog
Connecting
the
computer,
click
"My Computer" ""
Properties
""
Hardware
""
Device Manager ","
Universal
Serial
Transfer controller,
if
it
display
"SoftDog USB
Device"
that
means
working
properly,
if
not, pls check
whether push
out or the
driver
is
installed.

Website process
The first run of the site operational
procedures:

Login website

Test and complete

Add
Communication
Protocol

Change the user distribution

Set the alarm position and


detector position

3.1 Create/Edit communication protocol


(1) Login website
Enter in the browser "http://localhost/alarmsystem"
Default administrator account: admin , passwore: admin

Creating Customer
Information

Note:
URL format: http:// server IP address / virtual directory
Virtual directory: "that means virtual directory in the "alarm center setup" .
For example: the server's IP: 192.168.1.223
Virtual directory: alarmsystem
1. If this PC is the server.
Enter for browse "http://localhost/alarmsystem" or "http://192.168.1.223/alarmsystem"
2. If the server in the LAN.
Enter for browse: http//192.168.1.223/alarmsystem
(2) Add GSM communication protocol

Into the "System Setup" page, click on "GSM Alarm Receiver Setup", click "Add" will jump to
the "Communication config add" page, set it according to your need, the default configuration for
the speed is 9600, data bits: 8; Parity Check: none; Stop bit: 1. Phone number is SIM card uumber
in the GSM Alarm Receiver.
For example: The port in device manager before is Prolific USB-to-Serial Comm Port (COM9)
After selection, press confirm to complete the operation.

Go
to
"Open
Alam
System"
page,
click
"Alam
System is
Closed,
Whether
Open
it
or not".

After successful operation, Alarm system will start automatically in10 seconds. Following picture
shows the startup interface

Note: "edit" can only appear when there is a communications protocol, the contents of the serial
port name is the serial port which added before. If you need more ports, click on "Add" in the
section of "communication parameter configuration item"
Please remove the useless serial port, or it may lead to failure of the remote control. If you can not
start the alarm receiver, please check the softdog is inserted, while GSM Alarm Receiver Alarm
cat is connected

3.2 Change Client(Host) distribution map


Enter System Setup page, click Client Detail, click Change Client(host) distribution
background picture jump to upload picture page, upload your picture.

Note: Picture will be activate after restart the software.

3.3 Create client(host) information (Page: Client database)

Into the "Customer Database" page, click "New" will display the contents under the plan, select
"Host Type", enter "user name", "phone number" and the machine address, click "confirm" to
complete the operation. Example: user host ABC model G11 phone number is 13800138000
within the host, the machine address of the AAA

Note: If the host type is null, please add the "host type"page: System Setup>> Host SettingFor
detail please refer to "4.7.4 Create and change the Host Type/ Control Command."
For more practical system, please fill out optional items.

3.4 Configure the host and the detector

In the "Client Database" page, click on "Client Settings" will jump to "client settings" page

1) Change the alarm location


Click "change Position of Hosts" will jump to "coordinate choice" page, the default location in
the upper left corne.
Click the place where you are or drag the icon to your location.
Note: Blue hawk for disarm, Yellow hawk for arm, Red hawk for alarm.
2) Change the detector location
Operation please refer to 1) Change the alarm location or click the "edit" to input Coordinates.
Note: the icon now is red.

3.5 Software centre alarm test


It will sound and the red triangle will appear on the page when the preset alarm number called
GSM Alarm Receiver.

Note: If the above screen doesn't appear, please check the softdog is plugged in, GSM Alarm
Receiver is configured and whether the number already in "customer database."
The figure after clicking the "red triangle" or click the "fast track"

Click "Remove Alarm" for disarm. Click "Remark" for the history.
Alarm handle:
1.Fast track: Fast handle multiple alarms.

2.Alarm Records: Handle each alarm directly.


3.Click alarm icon on the map: Jump to client detailed information and handle single alarm.
Note: on the page of "Client Data Base," click "detail" and it will display "client today alarm
information"

Features navigation
System is based on permissions to restrict the operation, only the user with relevant permissions
can perform the relevant operations, such as: Administrators have the "edit" permission. No "edit"
permission's user only can view the content.

4.Function

of the Software

4.1 Login
1) Administrator login
The Administrator who have different permissions can perform different operations, for example:

User does not have the "edit" permission can not modify the relative information.
2) Client login
Client can only view the their personal alarm records, log regards and personal information; Also
can remote control the system set Remote control function can be set off by system setting

Note: Default Account: User Name; Password: 123456.


3. No need password to login. This need to be set by administrator, setting as below:

In "System Setup" page, click "Edit" will go to below figure:

Click "True" will see "Verification"

Tick the "Verification", "True" will become "false" , then click "Confirm."
Note: No-password-login client, do not have the "host-password modification " permissions

4.2 Alarm center

1. Click in the client (host) icon on the map, you can view the client (host) information, print,
remote control and send Email.
2. Click "Show Mini Navigate Map" which is at the top left corner, then mini map will be shown,
you can jump fast by click the "mini map" to the corresponding position. When alarm, the "mini
map" will appear red dot.
3. Click at the bottom of the page, to check today's alarm record
Note: 1. Client (host): a large map of the inside of the Blue Hawk [disarm] \ Yellow Hawk [arm] \
Red Hawk [alarm]). * Only user with the disarm's permission can remove the alarm.
4.3 Remote Control and Group Remote Control

This

function has two ways to remote or control the host, such as arm\ disarm\ quick arm\ partial arm:
1. In "Remote control" page, choose "phone number," click "Verification," if this phone number
correct, there will appear some corresponds notes below the "comfirm" button. If the Verification
pass, then the user's detector will be auto-loaded.ukuk
2. In "Alarm center" page, you can click the host you want to control on the map.

Then you will see this map as below:

Click "Remote Control" will jump to "Remote Control" page and fill in phone number, auto-load
"option" and the "arm zone". As the picture below:

Group Remote Control:


Go -Remote Control-Remote Control MoreIn

"Remote Control More" page, you can send message by group.

4.4
Alarm
Record

You can click the "detail" for further information

4.5
Logs
Log
records
can view
by
clicking
"details," or click "Search" and then choose a period, like the figure below:

4.6 client information

Add the new user: Click the button Add, follow the prompt fill all the information.
Edit the users information: click the button Edit, follow the prompt modify the information.
Delete the users information: click the button Delete, then there will be a the dialog box, please
click the OK.
Client Setting: Click Client Setting, there will skip to the setting page. It can
check\add\alter\delete the detector information, modify the clients position (Host) on the large
map (Host distribution) and the position on the mini map (Detector distribution). Pictures as
follow:
The host password is in Client databaseClient SettingChange the password
The initial password is: 1234
If the Host is G60, the password can be changed into 123456.
Setting:
you
can
check\add\alter\delete the detector
information, modify the clients
position (Host) on the large map
(Host distribution) and the
position on the mini map
(Detector distribution).
Client

the
Change the customers backgrounds, login in the alarm center page andYou
findcantheupload
Alarm
JPG/BMP/GIF/PNG
details, you can select the JPG/BMP/GIF/PNG format of the pictures to replaceformats
the olddocuments.
one.

*Change the host password: This change used for the password of remote control host. And only
the super administrator and make the change.
Note: If the host password from the website is different with the password on the host which be
matched, it can not remote control the host.
Click the "Change the alarm position" or "change the detector position", it will change to the
"position change page", like the picture below:

Change the alarm or detector position: Drag the icon to the place you want, then loose the left
mouse button, there will be a dialogue box jump out, if you click "YES," the position will update,
or you can relocation.
Note:
1. Change the alarm position: The icon is the blue hawkyellow hawk or red hawk.
2. Change the detector position: The icon is a red hawk.
System configuration

4.7.1 Operate Setup


Check Password Of LoginCheck that whether need to input the ID and password
when logon in the system
Check Password Of OperateCheck that whether need to input the password when
increase or modify the information.
Check Password Of Alarm DisarmCheck that whether need to input the password for
disarm the host.
Opening up the remote controlCheck that whether the user can use the remote control
when login in.
Sound options AllAll of the emergency will have the sound reminder; "Only
alarm": There will have the sound reminder only when the SMS contains "Alarm".
2.GSM Alarm Receiver Setup: Remember to add the corresponding port after the user
added the GSM alarm module. Default parameters are: [ Speed]9600[Data Bits]8[Parity
Check]None[Stop Bit]1.
3.Client Distribution Background Picture: Please alter the corresponding coordinate
of the alarm after the change of the background of the customer distribution.

4.Administrator Information
5.Host Settingadd the host type and the control command.
6.International Telephone Dialing CodeSwift to the international dial code.
7.Database Backup And RestoreDatabase Backup And Restore and set the frequency
of auto-backup.
8.Language optionSwift the English and Chinese options in the system.
9.Regionsadd the countries and areas
10.Remote Control Group frequencyThe default frequency of mass-message under
the control is 10 seconds. Two or more than two sets can turn down the count seconds, if the
count seconds is too low there will be unsuccessful transmit of SMS.
Note: Client Distribution Background Picture: The map in the page of "Alarm center"

4.7.2 Add the Communication Config


The communication protocol can help to realize the communication between the voice card and
GSM. Login in the page of "System Setup", click the column of "GSM Alarm Reciever Setup",
click "add" will skip to the page of "Communication Config Add", please kindly choose the option
according to your case, default setting is [Speed]9600[Data Bits]8[Parity Check]None[Stop Bit]1.
After the choose, please click the "Confirm" to finish this operation.
1. Modify the GSM Communication Config
Login in the page of "System Setup", click the column of "GSM Alarm Receiver Setup", there will
skip to the page of "Communication Config Edit" when click the "Edit", choose the port which
will be changed in the "Name", then select the parameters which need to be changed, press
"Confirm" to finish the operation.
Note: There will have the "Edit" function only when the communication protocol is exist, the
content of the port is the one already added. If need add more ports, please find the "Add" inside
of "GSM Alarm Receiver Setup". Please delete the none used ports, or else there will be failure if
use the remote control.

4.7.3 Administrator
This system will be distinguished the authorize by administrator-1. Can modify self and other administrator's authorize only when the "Edit permission" is
authorized;
2. Can add the information only when the "Add" is authorized;
3. Can delete the information only when the "Delete" is authorized;
4. Can edit the information only when the "Edit" is authorized;
5. Can add the remote control commands only when the "Add Control Commands" is authorized;
6. Can remote control the alarm host only when the "Remote control" is authorized;
7. Can disarm the host only when the "Disarm" is authorized;
8. Can do the backup of the database only when the "Database backup" is authorized.
Note: Can modify self information and other administrator's right only when the "Edit permission"
is authorized.;

4.7.4 Create and change the Host Type/ Control Command


1. Add the Host Type
Enter the System Setup then click the "Host Setting", add the host name and the host type then
click confirm.
Note If your host is T-5C or PH-T-2 series, please set the host type as "Only Call Telephone
Network Data Card," other host is as "default."
2. Add the Control Command
Enter the System Setup page then click the "Host Setting," chose the Host name add the type
name and the control coding, press confirm for confirmation.
Note: The type name is the name of command, can be changed by the user.
Control command is used for remote controlling and programming the alarm host, please add the
coding according to the user manual from different host model.
If the setting can not follow the command of the alarm host, the function of remote control can not
realize.

J) FAQ
Question 1: Website usage procedures?
New Client (Host) Register -- Entering Client (Host) detail, Delete / Change Host and Detector's
position -- complete.
[Remark]The default position of host and detector is (1, 1)
Question 2: How to add a new Client (Host)?
Situated: Client (Host) information --New -- Complete.
[Remark]After add new client (Host), remember to change the position of host and detector.
Question 3: How to change the location of hosts and detectors?
Situated: Client (Host) -- Details -1.Change the position of host: Click Change the position of Client(Host) -- icon is Blue Hawk,
Yellow Hawk, Red Hawk -- Using Mouse click icon, don't release left button, dragging the icon to
the position where you want, release left button, It will pop up a confirm window click "Yes" to
update, otherwise you can continue dragging.
2.Change the position of detector: Click" Change the position of Detector" -- icon is Red Hawk -Using Mouse click icon, don't release left button, dragging the icon to the position where you
want, release left button, It will pop up a confirm window click "Yes" to update, otherwise you can
continue dragging.
[Remark]Default coordinate (1, 1)
Question 4: Why some administrators can add/edit/delete messages, but I can't?
This system is distinguished by administrator permission
1. Have "Edit Permission" permission can edit yourself and other administrators' permission;

2. Have "Add" permission can add information;


3. Have "Delete" permission can delete information;
4. Have "Edit" Permission can edit information;
5. Have "Add commands" permission can add remotely control commands;
6. Have "Remote control" permission can remotely control host;
7. Have "Disarm" permission can cancel warning sound;
8. Have "Database Backup and Restore" permission can backup and restore the database;
[Remark]: Only have "Edit Permission" permission can edit yourself and other administrators'
permission;
Question 5: Why some icon in "Alarm Center" turn to red and issue warning sound? How to
cancel it?
When the Telephone Network Data Card receive the alarm information, As long as Click the red
icon (Alarm) in the "Alarm center". The warning sound will automatically vanish, at the same
time the icon turn to blue (disarm), As long as Click the red icon(alarm) in the "Alarm center".
[Remark]: Only have "Disarm" permission can cancel the warning sound.
Question 6: How to increase the IIS connections?
Internet Information Services (IIS) is limited in the number of instantaneous connections that can
be made to the system. This means we cannot have more users connected to the system at the
same time. . Solution: Manufacturer to consult with system developers on how to enable multiple
access on IIS
Microsoft provides a management tool for IIS, the latest version is 2.2. MetaEdit work in
Windows NT4.0, Windows 2000, it can also work in Windows XP, Moreover, MetaEdit can only
manage II4.0, IIS5.0 or higher version of IIS. Download address:
http://download.microsoft.com/download/iis50/Utility/5.0/NT45/EN-US/MtaEdt22.exe
After installing MetaEdit, in the Start menu under Administrative Tools program group, click
and run "MetaEdit 2.2," when there's a window, expand the directory tree on the left of the
window to the LM W3SVC, select the MaxConnections which under the Name list on the right
items, double-click, the dialog box will appears, the Data text box default is 10, this key can be
freely modified, no special restrictions, -1 for no limit
Then navigate to the LM W3SVC 1, select MaxConnections in the Name list, this is the "Default
Web Site" connections in IIS, and then double-click and modify the value in Date, but here the key
maximum is 40, more is useless. (Note: The maximum client connection IIS on Win 2000 is
2,000,000,000.) If you have multiple sites, you can modify in turn.

) Under windows9X/Me/NT/2000 Operating system


The old version driver user need reinstall soft dog kid V3.1 driver. The driver will
automatically check the operating system, whether it is the updated vision of soft dog driver.
Note: If user use the USB soft dog, before the driver installed, do not plug in the USB soft
dog. Otherwise cause the error when install the driver.
2) Install UDA soft dog driver under windows XP/Server2003
1. At first run the USB-soft Dog-driver the installation package
2. Plug in USB soft dog to the USB port on computer, The system automatically install the
updated driver due to the USB soft dog driver already have got the certification.
3)Uninstall Driver
Browse the soft dog Kit directory, Find and Run:\Driver\softdogInstdrv.exe. when Pop up window,
select Uninstall
2.5 Install Voice Card Driver
The operation need specific driver installation procedure;
1.Copy Driver\BfVoice
2.Copy file Driver\BfVoive8.sys to windows directory: system32\Drivers cover the old files.

3.Copy Driver\BfVoice.dll
4.Copy file Driver\BfVoive8.sys to windows directory : system32\Drivers cover the old files.
5.Restart computer.
NotePlease note that there are not any copy of BfVoice8.sys&BfVoice in the Windows
directory.
Page
3. Operations for Software Centre
If this is your first time use the Software, please do as this:
3.1 System Running
Open Internet Explorer web browser or other web browser (IE6 or above),
URL: http:// server IP address / virtual directory site alias
Virtual directory: "Alarm Center Setup" in the virtual directorysite Virtual alias
Directory: The directory name in alarm center installation
E.g. IP 192.168.1.223
Virtual Directory[website name]: alarm system
1.The computer is a server.
Url:"http://localhost/alarmsystem" or "http://192.168.1.223/alarmsystem"
2.LAN: Url: http://localhost/alarmsystem Or http://192.168.1.223/alarmsystem
Default username: admin,
Default password: admin
Page
3.2 Add/Edit Administrator Information
Change the administrator password:After you login your account, please change your password.
E.g: Enter into Administrator Information page, Click Edit then input the new password, click
Confirm. Complete the operation.
3.3 Add/Edit GSM communication protocol and Voice Card
Interval.
1) Add communication protocol
Only having protocolthe software can communicate with Voice Card and GSM Alarm Receiver.
Enter into System Setup page, click Communication Config.-Add-Communication
Password box
Confirm
Page
Config. page, please set the parameter as you want, the default Config.: speed: 9600, Digit
Bit:8;Parity check: None; stop bit:1
2) Change GSM communication protocol
Enter into System Setup, click communication config. Click Edit jump to Edit
communication config page, Select the port in the serial port name, then select the parameter,
click confirm complete.
3) Change the Voice Card Interval Time
Voice Card Interval Time: You can choose the best time for receiving one Alarm Message by this
operation.
And the time can be 400ms to 1500ms.You can set up by yourself.
Enter into System Setup , click Voice Card interval -Voice Card Interval -Edit

-Confirm .Then finish.


Default parameter:400ms
Only one card parameter range: 400ms-1500ms
Multi card parameter range:1-300
3.4 Add, Edit Host type and Remotely control command
Page
1) Add Host Type
Enter into Remotely control page, click Add control command - Add command -Add host
type to add type, click confirm to finish.
Note: If the Client(host)s Type is T-5C, T-2A, Please set the alarm Type as Only Call
Telephone Network Data Card,The other host type for default
2)Add remotely control command.
Enter remote control page, Click add control command jump to add Control command page,
click add control command to select host name, type and input control command. Click confirm
complete.
Note: Type is the command name.
Remotely control commands is the remotely control code, Please add is follow the manual.
If enter wrong command, the software can't remotely control host.
3.5 Change Client(Host) distribution map.
Enter System Setup page, click Client Detail, click Change Client(host) distribution
background picture jump to upload picture page, upload your picture.
3.6 Add Client(host) information
Page
1) Enter Client Database page, click Add can display the picture as below.
Fill the table with related content.
E.g.: The Client(host) is ABC and the Type is G10, The Client(Host) telephone number is
13800138000.
NoteIf the client(host) type is nullplease add Client (host) TypeFollow the instruction.
2) Change Client (host) and detectors position
Enter Client Database age, click Detail jump to Client details page.
Page
1.Change the position of Client (host)
Click Chang the position of Client (host) jump to coordinate select page, the default
coordinate is (0,0)
Method 1
Move the mouse to position what you want, and press left button of mouse, pop up a window,
click Confirm complete operation. Click Cancel to return.
Method 2
Using Mouse click icon, don't release left button ,dragging the icon to the position where you
want,
release left button, It will pop up a confirm window, click "Yes" to update, otherwise you can
continue dragging.
Note:The Blue hawk [Arm] Yellow hawk [Disarm] Red hawk [Alarm]
3.Change the position of detector

It is the same operation of the change client (host)s position.


If you dont want to change detectors position via using mouse, you can input the coordinates at
the end of detectors icon.
Note: Selected icon is Red Hawk
Page
4. Function of the Software
This system distinguish administrators permission. E.g.: some administrators only have "Edit"
Permission
4.1 login
1.Administrator login;
After login the system, with different permission administrator can execute
corresponding operation.
E.g.:
Login system without username and password, the administrator need set the system config. As
below:
Page
Enter System Config, in System Config Content click Edit jump to the window as below.
Click text box, As below.
Select Verification, then click Confirm
Note: if login system without password, the administrator cant change the client (host)
password.
4.2Alarm center
1. Click the client(host) icon in the map, can query client(host) details, print information, remotely
control and send E-mail, also can remotely control Client (Host).
2. Click Show navigation map on the left in the page, can show mini map, click on Mini map
jump to corresponding position in big map. When alarm is trigged, there is a red point in the
mini map.
3. Click show no alarm records can show the no daily alarm records. And set Alarm
inspection to Automatic alarm inspection.
textbox
The Client
(host)
Page
Note:
*. Client (host): In big map Blue Hawk (m)\Yellow Hawk
*. Only having Disarm permission, the administrator can disarm Client (host)
4.3 Remotely control
Can use this function to remotely control client(Host).Such as:Arm/disarm/quickarm/partial
arm/partial disarm.
.
1. On Remotely control page, Select Phone Number, then input phone number click Check,
after verify telephone number, It will appear information. If pass the verification, The option of
setting and guarding zones will automatically load.
E.g.: Remotely control Host(8613760156915) guarding zone 1 arm, select Arm in option, select

Guarding zone 1 click confirm to complete.


On Alarm center page, select the Client (host) what you want to remotely control.
Click Client (host) icon on Alarm Center page.
After input phone number, click Confirm Send control SMS.
Page
Pop up the window as below:
Click "Remotely control", jump to "Remotely control" page and automatically fill the Telephone
number, loading "option" and "Guarding zones". As below:
The Client (host)
Click the Client (host) in Alarm center page,
jump to this page
Can show, print information
and sent E-mail, Remotely
control
Page
4.4 Alarm Records
Click Detail
also can click Query alarm records via client name, telephone number or Host ID to proceed
to quickly query
4.5 Log
Click Detail , or click Log Records via select period time to proceed quick query.
Query alarm Records
Client Name, Telephone No. Host ID
Log records query
Page
4.6 Client Database
1.Add new client(Host): click Add,
2.Edit client(Host) information: click Edit
3.Delete client(Host) information: click Delete, pop up confirm window.
4.Details(client):click Detail, jump to Detail page, can Check\Add\Edit\Delete detectors
information and change Client(host)s position in big map and detectors position in small map.
4.1)Change Host password
Open Client Databaseclient setupchange password
Default: 1234
if the type of alarm host is G60, the default password is 123456
4.2) Edit user map:
change the background picture of "Alarm Detail " in "Alarm Center". support
format:JPG\BMP\GIF\PNG.
Click text boxpop up date box
window
Details can Check
\Add\Edit\Delete
Client(host)
Page

Change Client (host) password:


Note: Changing the Remotely control host password, only available for super administrator.
If the Client( host) password is not accordance with the remote host, then the host can not be
controlled remotely.
Click Change position of client (host), jump to Details
1.Using Mouse click icon, don't release left button, dragging the icon to the position where you
want, release left button, It will pop up a confirm window click "Yes" update, otherwise you can
continue dragging.
Note:
1. Changing the position of Client (host): icon is Blue hawk, Yellow hawk, Red hawk.
2. Changing the position of Detector: icon is Red hawk.
Can upload JPG\BMP\GIF\PN
Page
5. Administrator
This system distinguish administrators permission:
1.Have Edit Permission permission can edit yourself and other administrators permission.
2.Have Add permission can add information.
3.Have Delete permission can delete information.
4.Have Edit permission can edit information.
5.Have Add Commands permission can add remotely control commands.
6.Have Remotely Control permission can remotely control Client (Host).
7.Have Disarm permission can cancel warning sound.
8.Have Database Backup & Restore permission can backup and restore the database.
Note: Have Edit Permission permission can edit yourself and other administrators
permission.
6. System Setup
1.System config ( verification):
System password verification: whether login system need password or not.
Edit information verification: Whether Edit information need password or not.
2. Voice card setting:
After add new Data Card, remember to add corresponding port. default setting: Speed:9600, Data
bit:8, Parity: None stop bit:1.
3. Client(Host) distribution background:
After change the client(host)background picture, please change the corresponding host coordinate.
Note: Client(Host) distribution background picture is "Alarm center" map.
Page
7. FAQS
Faq1. Website usage?
1.Register new client(host)---enter into client (host) details, add\delete\change host and detectors
position---complete.
Note: The default coordinates is (1,1)
Faq 2. How to add a new Client(Host)?
1Click Client information -- Add -- Complete.
Note: After adding client information, please remember to change the client (host) and

detectors coordinates.
Faq 3: How to change the coordinate of client (host) and detector?
Click Client (host) information Detail -1.Change position of Client (host):
Click "Change Client (host) position" Blue, yellow, red Hawk Icon-- Using Mouse click icon,
don't release left button ,dragging the icon to the position where you want, release left button, It
will pop up a confirm window click "Yes" update, otherwise you can continue dragging.
2.Change position of Detector:
Click "Change Detector position" Red PatrolHawk Icon --Using Mouse click icon, don't release
left button, dragging the icon to the position where you want, release left button, It will pop up a
confirm window click "Yes" update, otherwise you can continue dragging.
Note: Default coordinates (1,1)
Faqs 4. why some administrators can add\edit\delete messages, but I can't?
This system distinguish administrators permission.
1.Have"Edit Permission" permission can edit yourself and other administrators' permission;
2.Have "Add" permission can add information
3.Have "Delete" permission can delete information
4.Have "Edit" Permission can edit information;
5. Have" Add commands" permission can add remote control commands
6.Have "Remote Control" permission can remotely control host
7.Have"Disarm"permission can cancel warning sound
8.Have"Database Backup & Restore" permission can backup and restore the database;
Edit Permission: "Administrator information" Edit -Note: Only having "Edit Permission" permission can edit yourself and other administrators'
permission.
Faqs 5: There is individual icon turn to red (alarm) and what I can do?
When the Voice Card receive the alarm information, As long as click the red icon(Alarm) on the
"Alarm center" page. The warning sound will automatically vanish, at the same time the icon turn
to blue(disarm)
Note: Only having "Disarm" permission can cancel the warning

Você também pode gostar