Escolar Documentos
Profissional Documentos
Cultura Documentos
RMT-840
ADJ
SECTION 6
ADJUSTMENTS
How to use
Acrobat Reader
Link
VIDEO SECTION ADJUSTMENT
SERVICE MODE
ADJUSTMENT REMOTE COMMANDER
DATA PROCESS
LEVEL 2
a
a
LEVEL 3
OVERALL
POWER
4. PRINTED WIRING BOARDS CK-143, FK-090, IF-122, JK-274, LB-106,
CD-522, DA-033, DB-018, VC-367 BOARD
AND
MA-431, MK-017, MR-048, PD-222, SE-150,
SCHEMATIC DIAGRAMS
SW-433, VA-119 BOARD
FP-228, FP-467, FP-826, FP-959, FP-961,
FP-962, FP-963, FP-964, FP-965, FP-966,
FP-967, FP-971, FP-972, FP-974, FP-975,
FP-976, FP-977, FP-980, FP-981 FLEXIBLE
CONTROL SWITCH BLOCK (CF5610,
PS5610, VS-5610, ZS-5610)
5. REPAIR PARTS LIST
EXPLODED VIEWS
ELECTRICAL PARTS
a (CD-522, DA-033, DB-018, VC-367 BOARD)
HDR-FX1/FX1E
9-876-770-51
2007I0800-1
2007.09
Published by Kohda TEC
TABLE OF CONTENTS
1.
1-1.
6-1.
1-1.
21.
22.
23.
24.
25.
26.
27.
28.
HDR-FX1/FX1E
1.
2.
HDR-FX1/FX1E
6. ADJUSTMENTS
1.
Procedure 1
Save the EVR data of the machine in which a board is going to be replaced. Download the saved data after a board
is replaced.
(Machine before starting repair)
PC
PC
Procedure 2
Remove the EEPROM from the board of the machine that is going to be repaired. Install the removed EEPROM
to the replaced board.
Remove the EEPROM and install it.
(Former board)
(New board)
Procedure 3
When the data cannot be saved due to defective EEPROM, or when the EEPROM cannot be removed or
installed, save the data from the same model of the same destination, and download it.
(Machine to be repaired)
(Machine to be repaired)
PC
HDR-FX1/FX1E
6-1
Replaced parts
Parts replacement
Lens device
Mechanism deck (Note)
LCD block LCD901 (LCD panell)
LCD block Backlight LED
EVF block LCD902 (LCD panel)
Mechanism deck M901 (Drum assy) Note
Mechanism MD block
PRISM assy (CD-522 board IC101 to 103)
CD-522 board IC104 to 106 (S/H)
LB-106 board D501 (backlight (EVF))
MR-048 board IC0101 (REC/PB AMP)
PD-222 board IC601 (RGB driver, Timing generator (LCD))
SE-150 board SE401/402 (PITCH /YAW sensor)
VA-119 board IC2201 (Video IN/OUT)
VC-367 board IC1101, X1101, X1102 (Timing generator)
VC-367 board IC1104 to 1106 (AGC, A/D conv.)
VC-367 board IC2021 (Base band process, etc.)
VC-367 board IC4001 (DV signal process,RF signal process)
VC-367 board IC6001 (RGB driver (EVF))
VC-367 board IC6002 (Timing generator (EVF))
Block replacement
Adjustment
Section
Adjustment
Initialization of
8,9,A,B,C,D,E,F,13,
14,18,19,1A,1B,1C,
1D,1E,1F page data
Camera
Color EVF
LCD
Mechanism
System control
Servo, RF
Video
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
6-2
z
z
z
z
z
z
z
z
z
z
z z
z z
z
z z
z
z
z
z
z z
z z
Table. 6-1-1(1).
HDR-FX1/FX1E
z z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
EEPROM
replacement
Initialization of
8,9,A,B,C,D,E,F,13,
14,18,19,1A,1B,1C,
1D,1E,1F page data
Camera
Color EVF
LCD
Mechanism
System control
Servo, RF
Video
z
z
z
z
z
z
Table. 6-1-1(2).
HDR-FX1/FX1E
6-3
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z z
z z
z
Supporting
Adjustment
Adjustment
Section
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
J-2
ND filter 0.1
J-6080-807-A
J-5
J-6
Adjustment remote
commander
(RM-95 upgraded)
J-6082-053-B
For PTB-1450:
J-6082-559-A
ND filter 0.4
J-6080-806-A
For PTB-450:
J-6020-250-A
J-7
J-3
ND filter 1.0
J-6080-808-A
J-4
Vector scope
J-8
J-9
For PTB-450:
J-6080-621-A
Camera table
J-6082-384-A
For PTB-1450:
J-6082-560-A
J-10
J-11
J-12
Flange back
adjustment jig
J-6082-563-A
CPC-8 jig
J-6082-388-A
Fig. 6-1-1.
HDR-FX1/FX1E
6-4
Extension cable
(28P 0.8mm)
J-6082-566-A
1-1-2.
Preparations
Note1: For details of how remove the cabinet and boards, refer to 2.
DISASSEMBLY.
Note2: When performing only the adjustments, the lens block and boards
need not be disassembled.
Note3: Before performing the adjustments, check the data of page: 0,
address: 10 is 00. If not, set data: 00 to this address.
1)
Pattern box
100 cm (PTB-450)
40 cm (PTB-1450)
Fig. 6-1-2.
HDR-FX1/FX1E
6-5
[CONNECTION OF EQUIPMENT]
Adjustment remote
commander (RM-95)
CPC lid
Screw (M2x4)
LANC jack
CPC-8 jig
(J-6082-388-A)
DC-IN
AC IN
AC power
adaptor
Fig. 6-1-3.
HDR-FX1/FX1E
6-6
1-1-3. Precaution
1. Setting the Switch
Unless otherwise specified, set the switches as follows and perform adjustments without loading cassette.
1.
2.
3.
4.
5.
6.
7.
8.
9.
2. Order of Adjustments
Basically carry out adjustments in the order given.
Yellow
Cyan
Green
White
Magenta
Red
Blue
C=0, D=0
D
Yellow
Cyan
Green
White
Magenta
Red
Blue
A B
A=B
B A
Fig. a
(Component output terminal
Y signal output waveform)
Enrargement
Difference in level
Fig.6-1-4.
3. Subjects
1) Color bar chart (HD color bar standard picture frame)
When performing adjustments using the color bar chart, adjust
the picture frame as shown in Fig. 6-1-4. (Color reproduction
adjustment frame)
2) Clear chart (HD color bar standard picture frame)
Remove the color bar chart from the pattern box and insert a
clear chart in its place. (Do not perform zoom operations during
this time.)
3) Flange back adjustment chart
Make the chart shown in Fig. 6-1-5 using A0 size (1189mm
841mm) black and white vellum paper.
White
841mm
Black
1189mm
Fig. 6-1-5.
Note: Use matte vellum paper bigger than A0, and make sure the edges of
the black and white paper joined together are not rough.
HDR-FX1/FX1E
6-7
1-2.
INITIALIZATION OF 8, 9, A, B, C, D, E, F, 13,
14, 18, 19, 1A, 1B, 1C, 1D, 1E, 1F PAGE DATA
Note: When reading or writing the 13, 14, 18, 19, 1A, 1B, 1C, 1D, 1E, 1F
page data, select page: 0, address: 10, and set data: 01, then select 3,
4, 8, 9, A, B, C, D, E or F page. The 13, 14, 18, 19, 1A, 1B, 1C, 1D,
1E or 1F page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
1-2-1.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) When changing the A, B, D page data, select page: 0, address:
10, and set data: 00.
3) When changing the 1A, 1B page data, select page: 0, address:
10, and set data: 01.
After completing the modification of 1A, 1B page data, reset
the data of this address to 00.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
Note1: If the A, B, D, 1A, 1B page data has been initialized, the following
adjustments need to be performed again.
1) Modification of A, B, D, 1A, 1B page data
5)
Adjusting page
Adjusting Address
Adjusting page
10 to FF
B
Adjusting Address
Adjusting page
00 to FF
D
1
2
0
2
10
00
00
29
Adjusting Address
Adjusting page
10 to 7A
1A
01
29
Adjusting Address
Adjusting page
00 to FF
1B
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
1
2
0
0
01
10
04
02
Procedure
01
00
01
XX
00
01
3. A Page Table
Note1: The data of page: 0, address: 10 must be 00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the A, B,
D, 1A, 1B Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of A, B,
D, 1A, 1B Page Data).
Address
00 to 0F
10
11 to 17
18
19 to 2E
2F
30
31
32 to FF
Perform Modification of A, B,
D, 1A, 1B Page Data.
Initial value
00
Remark
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-2.
HDR-FX1/FX1E
6-8
4. B Page Table
6. 1A Page Table
Note1: When reading or writing the 1A page data, select page: 0, address:
10, and set data: 01, then select A page. The 1A page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the A, B,
D, 1A, 1B Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of A, B,
D, 1A, 1B Page Data).
Address
00 to FF Fixed data-1
Remark
Table. 6-1-3.
Address
00 to C4
C5
C6 to CE
CF
D0 to D3
D4
D5
D6
D7 to D8
D9
DA to D0
DE
DF to E2
E3
E4 to EC
ED
EE to F1
F2
F3
F4
F5 to F6
F7
F8 to FB
FC
FD to FF
5. D Page Table
Note1: The data of page: 0, address: 10 must be 00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the A, B,
D, 1A, 1B Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of A, B,
D, 1A, 1B Page Data).
Address
00 to 0F
10 to 15
16
17 to 27
28
29
2A
2B
2C
2D
2E
2F
30
31 to 32
33
34 to 56
57
58 to 79
7A
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Table. 6-1-4.
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-5.
7. 1B Page Table
Note1: When reading or writing the 1B page data, select page: 0, address:
10, and set data: 01, then select B page. The 1B page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the A, B,
D, 1A, 1B Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of A, B,
D, 1A, 1B Page Data).
Address
00 to FF Fixed data-1
Remark
Table. 6-1-6.
HDR-FX1/FX1E
6-9
1-2-2.
Note1: When reading or writing the 8, C page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 13, 18, 1C page data, select page: 0,
address: 10, and set data: 01, then select 3, 8 or C page. The 13, 18
or 1C page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: NTSC model: HDR-FX1
PAL model: HDR-FX1E
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) When changing the 8, C page data, select page: 0, address: 10,
and set data: 00.
3) When changing the 13, 18, 1C page data, select page: 0, address:
10, and set data: 01.
After completing the modification of 13, 18, 1C page data,
reset the data of this address to 00.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
5)
6)
Adjusting page
Adjusting Address
Adjusting page
00 to FF
C
Adjusting Address
Adjusting page
10 to FF
13
1
2
0
2
10
00
00
29
Adjusting Address
Adjusting page
00 to FF
18
01
29
Adjusting Address
Adjusting page
00 to FF
1C
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
1
2
0
0
01
10
01
00
3
4
3
3
81
80
00
0C
80
1
2
Procedure
Note:
HDR-FX1/FX1E
6-10
0
3
10
FF
00
3. 8 Page Table
4. C Page Table
Address
00 to 7D
7E
7F to 83
84
85 to 9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9 to AC
AD
AE to B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
BE to BF
C0
C1
C2
C3
C4
C5
C6 to C7
C8
C9
CA
CB
CC
CD
CE
CF
D0
D1
D2
D3
D4 to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Table. 6-1-6.
HDR-FX1/FX1E
6-11
Remark
Fixed data-1
CAP FG duty adj.
Fixed data-1
S VIDEO out Y level adj. (Note3)
S VIDEO out chroma level adj.
(Note3)
Fixed data-1
Backlight adj. (EVF)
VCO adj. (EVF)
VCOM level adj. (EVF)
RGB AMP adj. (EVF)
Fixed data-1
PSIG level adj. (EVF)
White balance adj. (EVF)
Contrast adj. (EVF)
Fixed data-1
VCO adj. (LCD)
V COM adj. (LCD)
RGB AMP adj. (LCD)
Fixed data-1
Transmissive mode white balance
adj. (LCD)
Contrast adj. (SD) (LCD)
Fixed data-1
Fixed data-2
Fixed data-1
Sample hold phase adj. (LCD)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Reflective mode white balance adj.
(LCD)
C page
6. 18 Page Table
Address Initial value
NTSC PAL
72
73
74 to 75
76
31
31
77
18
18
78 to 81
82
75
75
83
36
36
84
36
36
85
70
70
86
2A
2A
87
2A
2A
88 to F3
F4
00
00
F5
00
00
F6
00
00
F7
00
00
F8
00
00
F9
00
00
FA
00
00
FB
00
00
FC
00
00
FD
00
00
FE
00
00
FF
00
00
Note1: When reading or writing the 18 page data, select page: 0, address:
10, and set data: 01, then select 8 page. The 18 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,
13, 18, 1C Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,
13, 18, 1C Page Data).
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Contrast adj.(HD) (LCD)
Contrast adj. (EVF)
Fixed data-1
COMPONENT OUTPT level adj.
Address
00 to 5D Fixed data-1
5E
Fixed data-2
5F to FF Fixed data-1
Table. 6-1-9.
7. 1C Page Table
Note1: When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,
18, 1C Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,
18, 1C Page Data).
Address
00 to 42
43
44 to 46
47
48
49
4A to 4D
4E
4F
50
51
52
53
54
55
56
57
58
59 to 5D
5E
5F to 66
67
68 to 69
6A
6B to B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
Table. 6-1-7.
5. 13 Page Table
Note1: When reading or writing the 13 page data, select page: 0, address:
10, and set data: 01, then select 8 page. The 13 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,
13, 18, 1C Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,
13, 18, 1C Page Data).
Address
Initial value
00 to 0F
04
05
06
07
08
09
0A
0B
0C to 12
13
14 to 24
25
26 to FF
08
00
46
01
02
00
00
00
Remark
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-8.
HDR-FX1/FX1E
6-12
Initial value
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
00
00
00
00
00
80
00
00
00
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Error rate check
1C page
2. Modification of 9, 1D Page Data
If the 9, 1D page data has been initialized, change the data of the
Fixed data-2 address shown in the following table by manual input.
Address
Remark
Initial value
BC
00
Error rate check
BD
00
BE
00
BF
00
C0
00
C1
00
C2
00
C3
80
C4
00
C5
00
C6
00
C7
00
C8
00
C9 to FB
Fixed data-1
FC
Fixed data-2
FD to FF
Fixed data-1
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) When changing the 9 page data, select page: 0, address: 10,
and set data: 00.
3) When changing the 1D page data, select page: 0, address: 10,
and set data: 01.
After completing the modification of 1D page data, reset the
data of this address to 00.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
5)
6)
Table. 6-1-10.
1-2-3.
Note: When reading or writing the 9 page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 1D page data, select page: 0, address:
10, and set data: 01, then select D page. The 1D page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Adjusting page
Adjusting Address
1D
00 to FF
Initializing Method:
Order Page Address Data
10
00
00
29
01
29
Address
00 to 0F
10 to FF Fixed data-1
Remark
Table. 6-1-11.
4. 1D Page Table
Note1: When reading or writing the 1D page data, select page: 0, address:
10, and set data: 01, then select D page. The 1D page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: The data of page: 0, address: 10 must be 00.
Note3: Fixed data-1: Initialized data. (Refer to 1. Initializing the 9, 1D
Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 9, 1D
Page Data).
Procedure
1
2
0
0
01
10
01
00
3
4
3
3
81
80
00
04
80
0
2
9
10 to FF
1
2
3. 9 Page Table
Adjusting page
Adjusting Address
Address
00 to FF Fixed data-1
Remark
Table. 6-1-12.
HDR-FX1/FX1E
6-13
1-2-4.
4)
Note: When reading or writing the E, F page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 14, 19, 1E and 1F page data, select
page: 0, address: 10, and set data: 01, then select 4, 9, E or F page.
The 14, 19, 1E or 1F page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note: If copy the data built in the different model, the camcorder may
not operate.
5)
Adjusting Address
Adjusting page
00 to FF
F
Adjusting Address
Adjusting page
10 to FF
14
Adjusting Address
Adjusting page
00 to FF
19
Adjusting Address
Adjusting page
00 to FF
1E
Adjusting Address
Adjusting page
00 to E5
1F
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
1
2
0
0
01
10
01
03
02
01
01
00
01
00
6)
Adjusting page
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
0
2
10
00
00
29
01
29
3. E Page Table
Note1: The data of page: 0, address: 10 must be 00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the E, F,
14, 19, 1E, 1F Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of E, F,
14, 19, 1E, 1F Page Data).
Address
00 to 17
18
19
1A
1B
1C
1D
1E
1F to 58
59
5A to 64
65
66
67
68
69
6A
6B to 80
81
82
83
84 to 90
91
92 to D3
D4
D5
D6 to D8
D9
DA to FF
Procedure
Set the data.
Set the data.
Set the following data, and press
PAUSE button.
2D: HDR-FX1 (NTSC)
2F: HDR-FX1E (PAL)
Set the data, and press PAUSE
button.
Check that the data changes to
01.
Set the data, and press PAUSE
button.
Perform Modification of E, F,
14, 19, 1E, 1F Page Data.
Remark
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-13.
HDR-FX1/FX1E
6-14
4. F Page Table
Note1: The data of page: 0, address: 10 must be 00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the E, F,
14, 19, 1E, 1F Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of E, F,
14, 19, 1E, 1F Page Data).
Remark
Fixed data-1
HALL adj.
Fixed data-1
MAX GAIN adj.
LV standard data input
Fixed data-1
HALL adj.
Fixed data-1
AWB standard data input
ND OFF
Fixed data-1
Color reproduction adj.
ND OFF
Fixed data-1
Flange back adj.
HDR-FX1/FX1E
6-15
F page
5. 14 Page Table
Address Initial value
NTSC PAL
C4
00
00
C5
EF
EF
C6
1E
1E
C7
2F
2F
C8
00
00
C9
EF
EF
CA
1E
1E
CB
2F
2F
CC
19
19
CD
E4
E4
CE
07
07
CF
F0
F0
D0
0F
0F
D1
4D
4D
D2
0D
0D
D3
E4
E4
D4
19
19
D5
AB
AB
D6
08
08
D7
30
30
D8
0F
0F
D9
13
13
DA
0E
0E
DB
76
76
DC
00
00
DD
EF
EF
DE
1E
1E
DF
2F
2F
E0
00
00
E1
EF
EF
E2
1E
1E
E3
2F
2F
E4
00
00
E5
EF
EF
E6
1E
1E
E7
2F
2F
E8
75
75
E9
72
72
EA
11
11
EB
C0
C0
EC
40
40
ED
C0
C0
EE
40
40
EF
C0
C0
F0
40
40
F1
C0
C0
F2
40
40
F3
C0
C0
F4
00
00
F5 to FF
Note1: When reading or writing the 14 page data, select page: 0, address:
10, and set data: 01, then select 4 page. The 14 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the E, F,
14, 19, 1E, 1F Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of E, F,
14, 19, 1E, 1F Page Data).
Remark
Color reproduction adj. ND 1
Address
00 to FF Fixed data-1
Remark
Table. 6-1-15.
AWB standard data input ND 1
Table. 6-1-14.
HDR-FX1/FX1E
6-16
6. 19 Page Table
7. 1E Page Table
Note1: When reading or writing the 19 page data, select page: 0, address:
10, and set data: 01, then select 9 page. The 19 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the E, F,
14, 19, 1E, 1F Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of E, F,
14, 19, 1E, 1F Page Data).
Note1: When reading or writing the 1E page data, select page: 0, address:
10, and set data: 01, then select E page. The 1E page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the E, F,
14, 19, 1E, 1F Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of E, F,
14, 19, 1E, 1F Page Data).
Address
00 to 69
6A
6B to 6D
6E
6F
70
71 to 78
79
7A
7B
7C
7D to 81
82
83 to 85
86
87 to FF
Address
00 to 74
75
76
77
78 to CD
CE
CF
D0 to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-17.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-16.
HDR-FX1/FX1E
6-17
8. 1F Page Table
Note1: When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the E, F,
14, 19, 1E, 1F Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of E, F,
14, 19, 1E, 1F Page Data).
Address
00 to 0D
0E
0F to 10
11
12
13 to 15
16
17 to 4D
4E
4F to 50
51
52
53
54
55 to D5
D6
D7
D8 to E1
E2
E3
E4 to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-18.
HDR-FX1/FX1E
6-18
1-3.
Subject
Not required
Measurement Point
Measuring Instrument
Specified Value
f=40454500800Hz (NTSC)
f=40500000800Hz (PAL)
Switch setting:
POWER .................................................................. CAMERA
Adjusting method:
Check that the frequency (f) satisfies the specified value.
1
4
8
5
IC1107
R150
R151
R149
IC104
Fig. 6-1-6.
HDR-FX1/FX1E
6-19
IC105
IC106
2. HALL Adjustment
For detecting the position of the lens iris and ND filter, adjust AMP
gain and offset.
Subject
Not required
Checking method:
Order Page Address Data
0
6
03
01
03
00
01
01
01
03
01
69
01
6B
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
F
13 to 17, 24 to 27
Specified Value 1
Specified Value 2
86 to 8A
15 to 19
Specified Value 3
Specified Value 4
29 to 33
6D to 77
10
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01 Set the data.
2
3
6
6
94
95
88
17
4
5
6
6
96
97
72
2E
01
6D
02
01
00
Procedure
1
2
HDR-FX1/FX1E
6-20
2
3
6
6
95
96
00
00
4
5
6
6
97
01
00
00
6
7
0
0
03
01
00
00
3. MR Adjustment
The MR (Magnet resistor) adjustment of the inner focus lens is
carried out automatically. In whichever case, the focus will be
deviated during auto focusing/manual focusing.
Subject
Not required
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
F
70 to 7C
Specified Value1
Specified Value2
40 to C0
03 to 78
Specified Value3
88 to F8
Note1:
Note2:
Note3:
Note4:
Adjusting method:
Order Page Address Data
1
2
0
F
01
70
01
02
71
72
73
74
75
10
76
11
77
12
78
13
79
14
7A
15
7B
16
7C
01
BD
Procedure
Set the data.
Set bit2 and bit3 of the data to
0, and press PAUSE button.
(Note6)
01
00
01
00
HDR-FX1/FX1E
6-21
Measurement Point
Measuring Instrument
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
F
70, A6, A7, EC to EF
Adjustment Page
Adjustment Address
F
70, A8, A9, F0 to F3
Specified Value1
Specified Value2
40 to C0
03 to 78
Specified Value1
Specified Value2
40 to C0
03 to 78
Specified Value3
88 to F8
Specified Value3
88 to F8
Adjusting method:
Adjusting method:
70
3
4
01
02
A6
A7
EC
ED
10
EE
11
EF
B1
70
01
02
A8
A9
F0
F1
10
F2
11
F3
01
00
B3
Note3: The rotating time between TELE end and WIDE end must be 1
sec. or more.
Note4: The adjustment data will be automatically input to page: F, address:
70, A8, A9, F0 to F3.
Note5: For the bit values, refer to 6-4. SERVICE MODE, 4-3. 3. Bit
value discrimination.
HDR-FX1/FX1E
6-22
01
00
Adjustment Page
Adjustment Address
F
E8 to EB
Specified Value
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01 Set the data.
2
01
B5
3
4
5
01
02
03
B7
28
01
00
HDR-FX1/FX1E
6-23
Adjustment Page
Adjustment Address
F
60 to 70, F4
Specified Value
Below 3 cm
Camcorder
Note1: Dark Siemens star chart.
Note2: This adjustment should be carried out upon completion of the
following adjustments.
HALL Adjustment, MR Adjustment
Note3: Make the lens horizontal and perform this adjustment.
Note4: The data of page: 0, address: 10 must be 00.
Note5: Check that the data of page: 6, address: 02 is 00. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Fig. 6-1-8.
Adjusting method:
Order Page Address Data
Switch setting:
ND FILTER ............................................................................. OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
Preparations for the minipattern box:
1) Remove the lens food.
2) The minipattern box is installed as shown in the following
figure.
Note: The attachment lenses are not used.
3)
4)
5)
6)
1
2
0
6
01
01
01
13
01
27
02
6F
Specified voltage:
The specified voltage varies according to the minipattern box, so
adjust the power supply output voltage to the specified voltage
written on the sheet which is supplied with the minipattern box.
01
00
01
00
Below 3 cm
Minipattern box
Camcorder
Camera
table
Regulated power supply
Output voltage : Specified voltage 0.01Vdc
Output current : more than 3.5A
Red (+)
Black ()
Yellow (SENS +)
White (SENS )
Procedure
Black (GND)
Fig. 6-1-7.
HDR-FX1/FX1E
6-24
Adjustment Page
Adjustment Address
F
60 to 70, F4
Specified Value
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01 Set the data.
2
01
13
01
15
02
6F
01
00
13
01
29
02
01
Procedure
01
01
F
60 to 70, F4
Preparations:
1) Set the zoom to the TELE end and expose a subject that is
more than 500m away (subject with clear contrast such as
building, etc.). (Nearby subjects less than 500m away should
not be in the screen.)
Preparations:
1) Check that at both the zoom TELE end and WIDE end, the
center of the chart and center of the monitor TV screen coincide.
0
6
Adjustment Page
Adjustment Address
Switch setting:
ND FILTER ............................................................................. OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
Switch setting:
ND FILTER ............................................................................. OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
1
2
Adjusting method:
Order Page Address Data
Measurement Point
Measuring Instrument
HDR-FX1/FX1E
6-25
Specified Value
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
Checking method:
1) Place the Siemens star 2.0m from the front of the lens.
2) To open the IRIS, decrease the luminous intensity to the
Siemens star up to a point before noise appear on the image.
3) Shoot the Siemens star with the zoom TELE end.
4) Set the FOCUS switch to AUTO.
5) Check that the lens is focused.
6) Set the FOCUS switch to MANUAL.
9) Change the zoom to the WIDE side from the TELE side, and
observe the TV monitor and check that the lens is focused.
HDR-FX1/FX1E
6-26
COMPONENT connector
Oscilloscope and HD TV monitor
Specified Value
C=D
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3) FOCUS .................................................................. MANUAL
4) ZOOM RING/LEVER ............................................... LEVER
Setting method:
Order Page Address Data
1
2
6
6
2C
90
91
92
5
6
6
6
11
Fig. 6-1-9.
2. Vertical period
Procedure
E = 0 (msec), F = 0 (msec)
93
01
79
Fig. 6-1-10.
D
C
A=B
E = 0 (mm)
C=D
F = 0 (mm)
Note3: When using the clear chart, remove the color bar chart from the
pattern box and insert a clear chart in its place. (Do not perform
zoom operations during this time.)
F
Color bar chart picture frame
6
6
2C
01
00
00
4
5
6
6
90
91
00
00
6
7
6
6
92
93
00
00
Fig. 6-1-11.
HDR-FX1/FX1E
6-27
F
2A to 2D
Adjustment Page
Adjustment Address
F
CC to CF
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3) FOCUS .................................................................. MANUAL
4) ZOOM ........................................................................ LEVER
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ........................................................................... 1
(Page: 6, Address: 9B, Bit4=1, Bit5=0)
3) FOCUS .................................................................. MANUAL
4) ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Adjusting method:
Order Page Address Data
Procedure
1
2
0
6
01
01
01
11
01
0B
02
01
00
01
01
01
11
01
0B
02
1
2
Procedure
2
3
HDR-FX1/FX1E
6-28
01
00
F
D4 to D7
Adjustment Page
Adjustment Address
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ........................................................................... 2
(Page: 6, Address: 9B, Bit4=0, Bit5=1)
3) FOCUS .................................................................. MANUAL
4) ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
1
2
01
01
01
11
01
0B
02
F
19
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3) STEADY SHOT (CAMERA SET menu) ........................ OFF
4) FOCUS .................................................................. MANUAL
5) ZOOM ........................................................................ LEVER
Procedure
Set ND FILTRE switch to 2.
Set the data.
Adjusting method:
2
3
6
6
30
C9
01
10
96
97
00
01
6F
02
01
00
HDR-FX1/FX1E
6-29
2
3
6
6
C9
96
00
00
4
5
6
6
97
01
00
00
01
00
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
F
1A, 1B
Filter
Specified Value
0FE0 to 1020
Adjustment Page
Adjustment Address
3C to 3F, 40 to 43
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3) FOCUS .................................................................. MANUAL
4) ZOOM ........................................................................ LEVER
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3) STEADY SHOT (CAMERA SET menu) ........................ OFF
4) FOCUS .................................................................. MANUAL
5) ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
1
Procedure
01
01
3
4
6
6
30
C9
01
10
01
0D
02
7
8
0
1
03
1E
Adjusting method:
2
3
0
F
01
3C
01
2B
3D
E0
3E
58
3F
78
01
83
01
81
02
6
6
30
C9
00
00
4
5
0
0
03
01
00
00
2
3
HDR-FX1/FX1E
6-30
01
00
Adjustment Page
Adjustment Page
Adjustment Address
3C to 3F, D0 to D3
Adjustment Address
3C to 3F, D8 to DB
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ........................................................................... 1
(Page: 6, Address: 9B, Bit4=1, Bit5=0)
3) FOCUS .................................................................. MANUAL
4) ZOOM ........................................................................ LEVER
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ........................................................................... 2
(Page: 6, Address: 9B, Bit4=0, Bit5=1)
3) FOCUS .................................................................. MANUAL
4) ZOOM ........................................................................ LEVER
Adjusting method:
Adjusting method:
01
01
3C
2B
3D
E0
3E
58
3F
78
01
83
01
81
10
02
2
3
01
01
3C
2B
3D
E0
3E
58
3F
78
01
83
01
81
10
02
01
00
2
3
HDR-FX1/FX1E
6-31
01
00
COMPONENT connector
Oscilloscope
Adjustment Page
Adjustment Address
F
38 to 3B (HD)
B4 to B7 (SD)
C0 to C3 (HD CINE)
DC to DF (SD CINE)
H
Note1: The data of page: 0, address: 10 must be 00.
Note2: Check that the data of page: 6, address: 02 is 00. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Fig. 6-1-12.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3) FOCUS .................................................................. MANUAL
4) ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Procedure
1
Set the color bar chart, and
check the picture frame.
(Refer to 10. Picture Frame
Setting.)
2
3
0
6
01
01
01
4D
9D
9E
22
6
7
6
6
12
12
80
00
8
9
01
10
02
61
HDR-FX1/FX1E
6-32
01
00
9D
00
01
00
Measurement Point
Measuring Instrument
COMPONENT connector
Oscilloscope
Measurement Point
Measuring Instrument
COMPONENT connector
Oscilloscope
Adjustment Page
Adjustment Address
F
AC to AF (HD)
B8 to BB (SD)
C4 to C7 (HD CINE)
E0 to E3 (SD CINE)
Adjustment Page
Adjustment Address
F
B0 to B3 (HD)
BC to BF (SD)
C8 to CB (HD CINE)
E4 to E7 (SD CINE)
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ........................................................................... 1
(Page: 6, Address: 9B, Bit4=1, Bit5=0)
3) FOCUS .................................................................. MANUAL
4) ZOOM ........................................................................ LEVER
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ........................................................................... 2
(Page: 6, Address: 9B, Bit4=0, Bit5=1)
3) FOCUS .................................................................. MANUAL
4) ZOOM ........................................................................ LEVER
Adjusting method:
Adjusting method:
0
6
01
01
9D
9E
6
7
6
6
12
12
01
4D
2
3
0
6
01
01
9D
22
9E
22
80
00
6
7
6
6
12
12
80
00
8
9
01
10
02
8
9
01
10
02
61
01
4D
61
6
0
9D
01
00
00
2
3
HDR-FX1/FX1E
6-33
6
0
9D
01
00
00
Checking method:
Order Page Address Data
Measurement Point
Measuring Instrument
Specified Value 1
Vectorscope
(LV5152)
Fig. 6-1-13 (A)
Specified Value 2
Specified Value 3
Adjustment remote
commander
01
0F
C9
10
5
Note1: The data of page: 0, address: 10 must be 00.
Note2: Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
01
00
01
3F
C9
10
01
00
2mm
R-Y
12
B-Y
2mm
13
01
23
14
15
0
1
03
06
R-Y
1mm
B-Y
3mm
0.5mm
10
11
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3) STEADY SHOT (CAMERA SET menu) ........................ OFF
4) FOCUS .................................................................. MANUAL
5 ZOOM ........................................................................ LEVER
Procedure
Indoor white balance check
Check that the lens is not
covered with either filter.
01
00
3mm
C9
00
3
4
03
00
HDR-FX1/FX1E
6-34
Checking method:
Order Page Address Data
Measurement Point
Measuring Instrument
Specified Value 1
Vectorscope
(LV5152)
Fig. 6-1-14 (A)
Specified Value 2
Specified Value 3
Adjustment remote
commander
01
0F
C9
10
01
00
6
Note1: The data of page: 0, address: 10 must be 00.
Note2: Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ........................................................................... 1
(Page: 6, Address: 9B, Bit4=1, Bit5=0)
3) STEADY SHOT (CAMERA SET menu) ........................ OFF
4) FOCUS .................................................................. MANUAL
5 ZOOM ........................................................................ LEVER
7
8
01
3F
C9
10
01
00
10
11
12
2mm
R-Y
14
01
23
15
03
06
16
2mm
B-Y
3mm
0.5mm
R-Y
1mm
LV data check
Place the ND filter 1.5
(1.0+0.1+0.4) on the lens.
13
B-Y
Procedure
3mm
01
00
C9
00
3
4
03
00
HDR-FX1/FX1E
6-35
Checking method:
Order Page Address Data
Procedure
Measurement Point
Measuring Instrument
Specified Value 1
Vectorscope (LV5152)
Fig. 6-1-15 (A)
01
0F
Specified Value 2
C9
10
01
00
Filter
6
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ........................................................................... 2
(Page: 6, Address: 9B, Bit4=0, Bit5=1)
3) STEADY SHOT (CAMERA SET menu) ........................ OFF
4) FOCUS .................................................................. MANUAL
5 ZOOM ........................................................................ LEVER
7
8
01
3F
C9
10
10
11
2mm
R-Y
B-Y
2mm
01
00
C9
00
1mm
3
B-Y
3mm
0.5mm
3mm
HDR-FX1/FX1E
6-36
Fig. 6-1-16.
For HD STD mode
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3) STEADY SHOT (CAMERA SET menu) ........................ OFF
4) FOCUS .................................................................. MANUAL
5) ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
1
Procedure
Set the color bar chart, and
check the picture frame.
(Refer to 10. Picture Frame
Setting.)
Set the data.
01
01
01
4D
9D
5
6
6
6
9E
12
22
80
7
8
12
00
Fig. 6-1-17.
01
00
9D
00
01
00
HDR-FX1/FX1E
6-37
Measurement Point
Specified Value
Measuring Instrument
Switch setting:
1) REC FORMAT (IN/OUT REC menu ................... HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ........................................................................... 1
(Page: 6, Address: 9B, Bit4=1, Bit5=0)
3) STEADY SHOT (CAMERA SET menu) ........................ OFF
4) FOCUS .................................................................. MANUAL
5) ZOOM ........................................................................ LEVER
Switch setting:
1) REC FORMAT (IN/OUT REC menu ................... HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ........................................................................... 2
(Page: 6, Address: 9B, Bit4=0, Bit5=1)
3) STEADY SHOT (CAMERA SET menu) ........................ OFF
4) FOCUS .................................................................. MANUAL
5) ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Adjusting method:
1
2
01
01
01
4D
9D
5
6
6
6
9E
12
22
80
7
8
12
00
Procedure
2
3
0
6
01
01
9D
9E
22
6
7
6
6
12
12
80
00
01
4D
01
00
9D
00
3
4
01
00
2
3
HDR-FX1/FX1E
6-38
6
0
9D
01
00
00
Fig. 6-1-18.
For HD CINE mode
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3) STEADY SHOT (CAMERA SET menu) ........................ OFF
4) FOCUS .................................................................. MANUAL
5) ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
1
Procedure
Set ND FILTRE switch to
OFF.
Set the data.
01
01
3
4
6
6
8A
9B
04
01
4D
9D
7
8
6
6
9E
12
22
80
9
10
12
00
11
Fig. 6-1-19.
Note5: For the bit values, refer to 6-4. SERVICE MODE, 4-3. 3. Bit
value discrimination.
Note6: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 .
01
00
8A
00
3
4
6
0
9D
01
00
00
HDR-FX1/FX1E
6-39
Measurement Point
Specified Value
Measuring Instrument
Switch setting:
1) REC FORMAT (IN/OUT REC menu ................... HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ........................................................................... 1
(Page: 6, Address: 9B, Bit4=1, Bit5=0)
3) STEADY SHOT (CAMERA SET menu) ........................ OFF
4) FOCUS .................................................................. MANUAL
5) ZOOM ........................................................................ LEVER
Switch setting:
1) REC FORMAT (IN/OUT REC menu ................... HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2) ND FILTER ........................................................................... 2
(Page: 6, Address: 9B, Bit4=0, Bit5=1)
3) STEADY SHOT (CAMERA SET menu) ........................ OFF
4) FOCUS .................................................................. MANUAL
5) ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Adjusting method:
Order Page Address Data
1
2
01
01
3
4
6
6
8A
9B
01
9D
7
8
6
6
9E
12
9
10
12
Procedure
Procedure
1
2
01
01
04
3
4
6
6
8A
9B
04
4D
01
4D
9D
22
80
7
8
6
6
9E
12
22
80
00
9
10
12
00
11
11
Note4: For the bit values, refer to 6-4. SERVICE MODE, 4-3. 3. Bit
value discrimination.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 .
Note4: For the bit values, refer to 6-4. SERVICE MODE, 4-3. 3. Bit
value discrimination.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 .
01
00
8A
3
4
6
0
9D
01
01
00
00
8A
00
00
00
3
4
6
0
9D
01
00
00
HDR-FX1/FX1E
6-40
Fig. 6-1-20.
For SD STD mode
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .............................. DV
(Page: 6, Address: 9B, Bit2=1)
2) ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3) STEADY SHOT (CAMERA SET menu) ........................ OFF
4) FOCUS .................................................................. MANUAL
5) ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
1
2
Procedure
Set REC FORMAT to DV.
Set ND FILTRE switch to
OFF.
3
4
0
6
01
01
01
4D
9D
9E
22
7
8
6
6
12
12
80
00
Fig. 6-1-21.
10
6
0
9D
01
00
00
HDR-FX1/FX1E
6-41
Measurement Point
Specified Value
Measuring Instrument
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .............................. DV
(Page: 6, Address: 9B, Bit2=1)
2) ND FILTER ........................................................................... 1
(Page: 6, Address: 9B, Bit4=1, Bit5=0)
3) STEADY SHOT (CAMERA SET menu) ........................ OFF
4) FOCUS .................................................................. MANUAL
5) ZOOM ........................................................................ LEVER
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .............................. DV
(Page: 6, Address: 9B, Bit2=1)
2) ND FILTER ........................................................................... 2
(Page: 6, Address: 9B, Bit4=0, Bit5=1)
3) STEADY SHOT (CAMERA SET menu) ........................ OFF
4) FOCUS .................................................................. MANUAL
5) ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Adjusting method:
Order Page Address Data
1
2
01
01
01
4D
9D
5
6
6
6
9E
12
7
8
12
Procedure
Procedure
1
2
01
01
01
4D
9D
22
80
5
6
6
6
9E
12
22
80
00
7
8
12
00
01
00
9D
00
3
4
01
00
01
00
9D
00
3
4
01
00
HDR-FX1/FX1E
6-42
Fig. 6-1-22.
For SD CINE mode
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .............................. DV
(Page: 6, Address: 9B, Bit2=1)
2) ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3) STEADY SHOT (CAMERA SET menu) ........................ OFF
4) FOCUS .................................................................. MANUAL
5) ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
1
Procedure
Set ND FILTRE switch to
OFF.
Set the data.
01
01
3
4
6
6
8A
9B
04
01
4D
9D
7
8
6
6
9E
12
22
80
9
10
12
00
11
Fig. 6-1-23.
Note5: For the bit values, refer to 6-4. SERVICE MODE, 4-3. 3. Bit
value discrimination.
Note6: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 .
70 IRE = 490 mV
01
00
8A
00
3
4
6
0
9D
01
00
00
HDR-FX1/FX1E
6-43
Measurement Point
Specified Value
Measuring Instrument
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .............................. DV
(Page: 6, Address: 9B, Bit2=1)
2) ND FILTER .............................................................................. 1
(Page: 6, Address: 9B, Bit4=1, Bit5=0)
3) STEADY SHOT (CAMERA SET menu) ........................ OFF
4) FOCUS .................................................................. MANUAL
5) ZOOM ........................................................................ LEVER
Switch setting:
1) REC FORMAT (IN/OUT REC menu) .............................. DV
(Page: 6, Address: 9B, Bit2=1)
2) ND FILTER ........................................................................... 2
(Page: 6, Address: 9B, Bit4=0, Bit5=1)
3) STEADY SHOT (CAMERA SET menu) ........................ OFF
4) FOCUS .................................................................. MANUAL
5) ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
Adjusting method:
Order Page Address Data
1
2
01
01
3
4
6
6
8A
9B
01
9D
7
8
6
6
9E
12
9
10
12
Procedure
Procedure
1
2
01
01
04
3
4
6
6
8A
9B
04
4D
01
4D
9D
22
80
7
8
6
6
9E
12
22
80
00
9
10
12
00
11
11
Note4: For the bit values, refer to 6-4. SERVICE MODE, 4-3. 3. Bit
value discrimination.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 .
70 IRE = 490 mV
Note4: For the bit values, refer to 6-4. SERVICE MODE, 4-3. 3. Bit
value discrimination.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 .
70 IRE = 490 mV
01
00
8A
3
4
6
0
9D
01
01
00
00
8A
00
00
00
3
4
6
0
9D
01
00
00
5
6
HDR-FX1/FX1E
6-44
Switch setting:
1) TV TYPE (IN/OUT REC menu) ................................... 16 : 9
2) ZOOM .................................................................... TELE end
3) FOCUS .................................................................. MANUAL
4) ND FILTER ...................................................................... OFF
37-1.
PSD Sensor Gain Adjustment (1)
Subject
Pattern A
(1.5m from the front of the lens)
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Adjusting method:
Order Page Address Data
0
F
01
84
01
80
01
91
4
5
6
Pattern A
01
8F
White
8
Black
White
Procedure
1
2
Fig. 6-1-24.
V
10
11
84
D84
Falling edge of
waveform when
data is 8F
SV2SV1
SV2 (msec)
SV1 (msec)
Fig. 6-1-25.
HDR-FX1/FX1E
6-45
37-2.
PSD Sensor Gain Adjustment (2)
Subject
Pattern B
(1.5m from the front of the lens)
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Adjusting method:
Order Page Address Data
0
F
01
85
01
80
01
91
4
5
6
Black
Pattern B
01
8F
8
White
White
Fig. 6-1-26.
10
11
Procedure
1
2
85
D85
01
00
01
01
3
Falling edge of
waveform when
data is 8F
Falling edge of
waveform when
data is 91
SH1SH2
SH1 (sec)
SH2 (sec)
Fig. 6-1-27.
HDR-FX1/FX1E
6-46
1
2
0
F
01
84
85
01
1)
2)
Adjustment Page
Adjustment Address
86, 87
Note1: The sensor sensitivity of SE401 and SE402 of the SE-150 board is
written only on the repair parts.
Preparation:
1) Read the PITCH sensor (SE-150 board SE401) sensitivity
written on the repair parts, and name this as S401.
2) Read the YAW sensor (SE-150 board SE402) sensitivity written
on the repair parts, and name this as S402.
4
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Procedure
86
D86
87
D87
HDR-FX1/FX1E
6-47
1-4.
Subject
Measurement Point
Arbitrary
Pin 7 of CN107 of DA-033 board
(EVF VCO)
Measuring Instrument
Adjustment Page
Frequency counter
C
Adjustment Address
Specified Value
34, 35
f = 15734 30Hz (NTSC)
f = 15625 30Hz (PAL)
Switch setting:
1) POWER .................................................................. CAMERA
2) REC FORMAT (IN/OUT REC menu) .................. HDV1080i
3) LCD panel .................................................................... Closed
[Adjusting connector]
Most of the measuring points for adjusting the viewfinder system
are concentrated in CN107 of DA-033 board.
Connect the Measuring Instruments via the CPC-8 jig (J-6082-388A).
The following table shows the Pin No. and signal name of CN107.
Pin No.
Signal Name
Pin No.
Signal Name
1
2
0
C
01
34
3
4
C
C
34
34
01
1
3
EVF COM DC
REG GND
2
4
REG GND
MT 4.9V
5
7
EXT DA
EVF VCO
6
8
REG GND
MS LED ON
9
11
EVF VG
PSIG
10
12
MS BS
MS SCLK
13
15
RF MON
SWP
14
16
MS VCC ON
XMS IN
17
19
FRRV
REC CRRT1
18
20
MC DIO
REC CRRT0
35
D35
01
00
Table 6-1-19.
Procedure
35
35
35
CPC lid
Screw (M2x4)
CN107
1
19
20
Fig. 6-1-28.
HDR-FX1/FX1E
6-48
34
D34
01
00
Arbitrary
Pin 5 of CN107 of DA-033 board
(EXT DA)
Measuring Instrument
Adjustment Page
Digital voltmeter
C
Adjustment Address
Specified Value
32, 33
NORMAL mode : A=1.00 0.05Vdc
BRIGHT mode : B=1.65 0.05Vdc
32
33
33
01
Oscilloscope
C
Adjustment Address
Specified Value
39
A = 6.00 0.05V
Measuring Instrument
Adjustment Page
Adjusting method:
Adjusting method:
Arbitrary
Pin qa of CN107 of DA-033 board
(PSIG)
Subject
Measurement Point
39
39
01
2H
Fig. 6-1-29.
HDR-FX1/FX1E
6-49
Arbitrary
Pin 1 of CN107 of DA-033 board
(EVF COM DC)
Measuring Instrument
Adjustment Page
Digital voltmeter
C
Adjustment Address
Specified Value
36
A = 6.65 0.05Vdc
Adjusting method:
Order Page Address Data
1
2
3
4
0
C
C
0
01
36
36
01
01
00
Subject
Measurement Point
Arbitrary
Pin 9 of CN107 of DA-033 board
(EVF VG)
Measuring Instrument
Adjustment Page
Oscilloscope
C
Adjustment Address
Specified Value
37
A = 7.00 0.10V
Procedure
Adjusting method:
Order Page Address Data
1
2
0
C
01
37
3
4
C
0
37
01
01
Procedure
Set the data.
Change the data and set the
voltage (A) to the specified
value.
Press PAUSE button.
Set the data.
Pedestal
2H
Pedestal
Fig. 6-1-30.
HDR-FX1/FX1E
6-50
Arbitrary
Pin 9 of CN107 of DA-033 board
(EVF VG)
Measuring Instrument
Adjustment Page
Oscilloscope
C
Adjustment Address
Specified Value
3C, 77
A = 2.57 0.05V
1
2
01
01
3C
5
6
7
8
C
0
77
01
Procedure
Set the data.
Set REC FORMAT (IN/OUT
REC menu) to DV.
00
C
3A, 3B
The EVF screen should not be
colored.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01 Set the data.
77
Measuring Instrument
Adjustment Page
Note1: Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC6001
Note2: The data of page: 0, address: 10 must be 00.
3C
Arbitrary
Check on EVF screen
Adjustment Address
Specified Value
Adjusting method:
Order Page Address Data
Subject
Measurement Point
100 IRE
2H
Pedestal
Fig. 6-1-31.
HDR-FX1/FX1E
6-51
3A
80
3B
80
3A
3A
6
7
C
C
3A
3B
8
9
C
C
3B
3B
10
01
00
1-5.
1
2
01
01
01
5A
Switch setting:
1) POWER .................................................................. CAMERA
2) LCD panel ...................................................................... Open
02
03
45
Subject
Adjustment Page
Arbitrary
C
Adjustment Address
Data of page: 3,
address: C6
53
54
58
Contents of error
10
46
D46
11
01
00
Switch setting:
REC FORMAT (IN/OUT REC menu) ..................................... DV
01
01
01
5A
02
03
46
6-52
Procedure
HDR-FX1/FX1E
Procedure
10
45
D45
12
01
00
Arbitrary
C
Adjustment Address
76
Switch setting:
REC FORMAT (IN/OUT REC menu) ......................... HDV1080i
Adjusting method:
Order Page Address Data
1
2
01
01
01
68
02
03
01
00
Arbitrary
Check on LCD display
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
47
The brightness difference between the
section A and section B is minimum.
Procedure
Set REC FORMAT (IN/OUT
REC menu) to HDV1080i.
Set the data.
Note1: This adjustment should be carried out upon completion of the LCD
automatic adjustment.
Note2: The data of page: 0, address: 10 must be 00.
Switch setting:
REC FORMAT (IN/OUT REC menu) ......................... HDV1080i
LCD BACKLIGHT .................................................................. ON
Adjusting method:
Order Page Address Data
Note2: If the data is 01, adjustment has errors. Contents of the error is
written into page: 3, addresses: C6. See the following table.
Data of page: 3,
address: C6
68
Subject
Measurement Point
01
0D
0
C
01
56
47
47
5
6
C
C
47
56
C3
01
00
Contents of error
Contrast adjustment (HD) error
Procedure
1
2
Fig. 6-1-32.
HDR-FX1/FX1E
6-53
Arbitrary
Check on LCD display
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
54
The LCD screen is brightest.
01
0C
01
20
22
0F
55
01
54
7
8
9
C
C
C
54
55
03
54
10
11
54
Dadj
12
55
00
13
0C
00
14
22
00
15
01
00
4B, 4C
The LCD screen should not be
colored.
Adjusting method:
Order Page Address Data
Procedure
1
2
0
C
01
4B
01
80
4C
80
4C
4B
4B
4C
4C
4C
10
01
54
Switch setting:
REC FORMAT (IN/OUT REC menu) ......................... HDV1080i
LCD BACKLIGHT .................................................................. ON
Procedure
0
3
Measuring Instrument
Adjustment Page
Note1: Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC601
Note2: The data of page: 0, address: 10 must be 00.
Switch setting:
REC FORMAT (IN/OUT REC menu) ......................... HDV1080i
LCD BACKLIGHT .................................................................. ON
1
2
Arbitrary
Check on LCD screen
Adjustment Address
Specified Value
Note1: This adjustment should be carried out upon completion of the LCD
automatic adjustment, contrast adjustment (HD) and V COM
adjustment.
Note2: The data of page: 0, address: 10 must be 00.
Adjusting method:
Order Page Address Data
Subject
Measurement Point
00
Fig. 6-1-33.
HDR-FX1/FX1E
6-54
Arbitrary
C
Adjustment Address
70, 71
Switch setting:
REC FORMAT (IN/OUT REC menu) ......................... HDV1080i
LCD BACKLIGHT ................................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
Set LCD BACKLIGHT to
OFF.
2
3
0
3
01
01
02
03
01
02
03
01
10
01
64
65
00
HDR-FX1/FX1E
6-55
2-3.
2-1.
1)
2)
3)
4)
5)
6)
7)
8)
5)
To quit the record mode, select page: 3, address: 01, set data:
00, and press the PAUSE button of the adjustment remote
commander. (Whenever you want to quit the record mode, be
sure to quit following this procedure.)
2-2.
1)
2)
3)
4)
5)
To quit the playback mode, select page: 3, address: 01, set data:
00, and press the PAUSE button of the adjustment remote
commander. (Whenever you want to quit the playback mode,
be sure to quit following this procedure.)
Pin No.
Signal Name
1
3
EVF COM DC
REG GND
2
4
REG GND
MT 4.9V
5
7
EXT DA
EVF VCO
6
8
REG GND
MS LED ON
9
11
EVF VG
PSIG
10
12
MS BS
MS SCLK
13
15
RF MON
SWP
14
16
MS VCC ON
XMS IN
17
19
FRRV
REC CRRT1
18
20
MC DIO
REC CRRT0
Table 6-2-1.
2. Processing after Completing Operations:
1) Connect the adjustment remote commander to the LANC jack
and set the HOLD switch to the ON position.
2) Select page: 3, address: 26, and set data: 00, and press PAUSE
button.
3) Select page: 3, address: 33, and set data: 00.
Entrance Check this section
(Normal waveform)
side
CH1
CH2
(Trigger)
3.3 msec
Fig. 6-2-1.
HDR-FX1/FX1E
6-56
Exit side
HDR-FX1/FX1E
6-57
3-1-2.
Precautions on Adjusting
1)
2)
3)
4)
5)
6)
7)
8)
9)
HDR-FX1/FX1E
6-58
Signal Name
Pin No.
Signal Name
1
3
EVF COM DC
REG GND
2
4
REG GND
MT 4.9V
5
7
EXT DA
EVF VCO
6
8
REG GND
MS LED ON
9
11
EVF VG
PSIG
10
12
MS BS
MS SCLK
13
15
RF MON
SWP
14
16
MS VCC ON
XMS IN
17
19
FRRV
REC CRRT1
18
20
MC DIO
REC CRRT0
CPC lid
CN107
Screw (M2x4)
19
Table 6-3-1.
Fig. 6-3-1.
TV monitor
VIDEO
(Yellow)
Main unit
AUDIO L (White)
Adjustment
remote
commander
(RM-95)
AUDIO R (Red)
LANC jack
AUDIO/VIDEO jack
Fig. 6-3-2.
HDR-FX1/FX1E
6-59
20
Name
Tracking standard (XH2-1)
SW/OL standard (XH2-3)
Audio operation check
(XH5-3 (NTSC), XH5-3P (PAL))
System operation check
(XH5-5 (NTSC), XH5-5P (PAL))
Use
Tape path adjustment
Switching position adjustment
Audio system adjustment
Operation check
Fig. 6-3-3 shows the 75% color bar signals recorded on the alignment
tape for Audio Operation Check.
Note2: Measure with video terminal (Terminated at 75 W)
Blue
Red
Magenta
Green
(75%)
1V
Cyan
Burst signal
Yellow
0.714V
White
Cyan
Green
Magenta
Red
Blue
White (75%)
Yellow
White (100%)
0.286V
0.286V
Black
I
White
(100%)
Black
Blue
Red
Magenta
Green
Cyan
0.3V
Yellow
White
0.7V
1V
Magenta
Red
Blue
White (100%)
Yellow
Cyan
Green
(100%)
0.3V
Burst signal
Audio input/output
Special stereo mini jack
Input level: 327mV
Input impedance: More than 47k
Output level: 327 mV (at load impedance 47 k)
Output impedance: Below 2.2 k
HDR-FX1/FX1E
6-60
3-2.
4)
Note: When reading or writing the 13 page data, select page: 0, address:
10, and set data: 01, then select 3 page. The 13 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Input method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 01.
3) Input the following data to page: 3, addresses: 04 to 08.
Note: Press the PAUSE button of the adjustment remote commander
each time to set the data.
Address
Data
04
08
05
00
06
46
07
01
08
04
4)
5)
D1 (Decimal)
000001 to 065535
065536 to 131071
131072 to 196607
196608 to 262143
262144 to 327679
327680 to 393215
393216 to 458751
458752 to 524287
524288 to 589823
589824 to 655359
655360 to 720895
720896 to 786431
786432 to 851967
851968 to 917503
917504 to 983039
983040 to 999999
09, 0A, 0B
Note: When reading or writing the 13 page data, select page: 0, address:
10, and set data: 01, then select 3 page. The 13 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Input method:
1) Select page: 0, address: 01, and set data: 01.
2) Read the serial No. on the name plate, and take it as D1.
Example: If the serial No. is 77881.
D1=77881
D1
D1-65536
D1-131072
D1-196608
D1-262144
D1-327680
D1-393216
D1-458752
D1-524288
D1-589824
D1-655360
D1-720896
D1-786432
D1-851968
D1-917504
D1-983040
Table 6-3-2.
Note: Use six digits of the low rank when a serial No. is more than
seven digits.
3)
D2 (Decimal)
HDR-FX1/FX1E
6-61
H1 (Hexadecimal)
(Service model code)
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
HexaHexaHexaHexaHexaHexaHexaHexaDecimal decimal Decimal decimal Decimal decimal Decimal decimal Decimal decimal Decimal decimal Decimal decimal Decimal decimal
(D3)
(D3)
(D3)
(D3)
(D3)
(D3)
(D3)
(D3)
(H3)
(H3)
(H3)
(H3)
(H3)
(H3)
(H3)
(H3)
0
256
512
768
1024
1280
1536
1792
2048
2304
2560
2816
3072
3328
3584
3840
4096
4352
4608
4864
5120
5376
5632
5888
6144
6400
6656
6912
7168
7424
7680
7936
0000
0100
0200
0300
0400
0500
0600
0700
0800
0900
0A00
0B00
0C00
0D00
0E00
0F00
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
1A00
1B00
1C00
1D00
1E00
1F00
8192
8448
8704
8960
9216
9472
9728
9984
10240
10496
10752
11008
11264
11520
11776
12032
12288
12544
12800
13056
13312
13568
13824
14080
14336
14592
14848
15104
15360
15616
15872
16128
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
2A00
2B00
2C00
2D00
2E00
2F00
3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
3A00
3B00
3C00
3D00
3E00
3F00
16384
16640
16896
17152
17408
17664
17920
18176
18432
18688
18944
19200
19456
19712
19968
20224
20480
20736
20992
21248
21504
21760
22016
22272
22528
22784
23040
23296
23552
23808
24064
24320
4000
4100
4200
4300
4400
4500
4600
4700
4800
4900
4A00
4B00
4C00
4D00
4E00
4F00
5000
5100
5200
5300
5400
5500
5600
5700
5800
5900
5A00
5B00
5C00
5D00
5E00
5F00
24576
24832
25088
25344
25600
25856
26112
26368
26624
26880
27136
27392
27648
27904
28160
28416
28672
28928
29184
29440
29696
29952
30208
30464
30720
30976
31232
31488
31744
32000
32256
32512
6000
6100
6200
6300
6400
6500
6600
6700
6800
6900
6A00
6B00
6C00
6D00
6E00
6F00
7000
7100
7200
7300
7400
7500
7600
7700
7800
7900
7A00
7B00
7C00
7D00
7E00
7F00
32768
33024
33280
33536
33792
34048
34304
34560
34816
35072
35328
35584
35840
36096
36352
36608
36864
37120
37376
37632
37888
38144
38400
38656
38912
39168
39424
39680
39936
40192
40448
40704
Table 6-3-3.
HDR-FX1/FX1E
6-62
8000
8100
8200
8300
8400
8500
8600
8700
8800
8900
8A00
8B00
8C00
8D00
8E00
8F00
9000
9100
9200
9300
9400
9500
9600
9700
9800
9900
9A00
9B00
9C00
9D00
9E00
9F00
57344
57600
57856
58112
58368
58624
58880
59136
59392
59648
59904
60160
60416
60672
60928
61184
61440
61696
61952
62208
62464
62720
62976
63232
63488
63744
64000
64256
64512
64768
65024
65280
E000
E100
E200
E300
E400
E500
E600
E700
E800
E900
EA00
EB00
EC00
ED00
EE00
EF00
F000
F100
F200
F300
F400
F500
F600
F700
F800
F900
FA00
FB00
FC00
FD00
FE00
FF00
3-3.
Adjusting Procedure:
1. CAP FG duty adjustment
2. Switching position adjustment
3. Error rate check
1. Cap FG Duty Adjustment (VC-367 Board)
Set the Cap FG signal duty cycle to 50% to establish an appropriate
capstan servo. If deviated, the uneven rotation of capstan and noise
can occur.
Measurement Point
Display data of page: 3, address: 02, 03
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
16
Data of page: 3, address: 02 is 00.
Data of page: 3, address: 03 is 00.
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting method:
Order Page Address Data
Procedure
1
Insert the SW/OL reference tape
and enter the VTR STOP mode.
2
3
0
C
01
10
21
01
02
03
01
01
EE
Adjusting method:
Order Page Address Data
Procedure
1
Close the cassette compartment
without inserting a cassette.
2
3
0
3
01
01
02
03
01
01
1B
00
0D
00
Note2: If the data of page: 3, address: 21 is 72, the tape top being played.
After playing the tape for 1 to 2 seconds, stop it, perform step 5
and higher.
If the data of page: 3, address: 21 is 62, the tape end being played.
After rewinding the tape, perform step 5 and higher.
Note3: If bit 0 of the data is 1, the EVEN channel is defective. If bit 1 is
1, the ODD channel is defective. Contents of the defect is written
into page: C, addresses: 10 and 12. See the following table. (For
the bit values, refer to 6-4. SERVICE MODE, 4-3. 4. Bit value
discrimination. ) If bit 3 of the data is 1, the tape end being
played, so rewind the tape and perform the adjustment again.
Note2: If the data is 01, adjustment has errors or the mechanism deck is
defective.
HDR-FX1/FX1E
6-63
Adjusting method:
Order Page Address Data
Arbitrary
Switch setting:
REC FORMAT (IN/OUT menu) .............................................. DV
Adjusting method:
Order Page Address Data
1
01
01
3
4
0
3
10
1D
00
01
40
02
03
Procedure
Set REC FORMAT (IN/OUT
menu) to DV.
Set the data.
01
01
3
4
0
C
10
0D
01
C8
5
6
10
00
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
B3 to C8
Data of page: 3, address: 02 is 00.
Data of page: 3, address: 03 is 00.
Data of page: 3,
address: 03
01
02
03
Procedure
Playback the recorded signal at
Preparations before
adjustments
Set the data.
Note3: If Error rate is abnormal, Check the use tape, clean the tape running
surface. And after inputting initial values to page 1C: address: B3
to C8, perform re-adjustment. (See Table 6-3-4.)
Note1: When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Initial
value
00
00
00
00
00
80
00
00
Address
Initial Address
value
BB
00
C3
BC
00
C4
BD
00
C5
BE
00
C6
BF
00
C7
C0
00
C8
C1
00
C2
00
Table 6-3-4.
Initial
value
80
00
00
00
00
00
Note4: When writing the 1C page data, select page: 0, address: 10, and
set data: 01, then select C page.
After writing the initial values, reset the data of page: 0, address:
10 to 00.
0
C
10
0D
01
00
4
5
0
0
01
10
00
00
HDR-FX1/FX1E
6-64
3-4.
Note1: Before perform the video system adjustments, check that the
specified value of Origin Oscillation Check of CAMERA
SYSTEM ADJUSTMENT is satisfied.
And check that the data of page: 0, address: 10 is 00. If not, set
data: 00 to this address.
Note2: NTSC model: HDR-FX1
PAL model: HDR-FX1E
Switch setting:
DISP OUTPUT (OTHERS menu) ............................ LCD PANEL
1. S VIDEO OUT Y Level Adjustment (VC-367 Board)
Mode
CAMERA
Subject
Measurement Point
Arbitrary
Y signal terminal of S VIDEO jack
(75 terminated)
Measuring Instrument
Adjustment Page
Oscilloscope
C
Adjustment Address
Specified Value
25 [85] (Note3)
A = 1000 14mV
02
11
25[85]
6
7
C
3
25[85]
0C
00
01
00
Oscilloscope
C
Adjustment Address
Specified Value
Measuring Instrument
Adjustment Page
Adjusting method:
Adjusting method:
Arbitrary
Chroma signal terminal of S VIDEO
jack (75 terminated)
External trigger: Y signal terminal of
S VIDEO jack
Subject
Measurement Point
Note4: For the bit values, refer to 6-4. SERVICE MODE, 4-3. 3. Bit
value discrimination.
2
3
0C
02
11
26[86]
6
7
C
C
26[86]
27[87]
8
9
27[87]
10
11
3
0
0C
01
00
00
Note4: For the bit values, refer to 6-4. SERVICE MODE, 4-3. 3. Bit
value discrimination.
H
Fig. 6-3-4.
0.28 sec (NTSC)
0.23 sec (PAL)
HDR-FX1/FX1E
Fig. 6-3-5.
6-65
Arbitrary
Video plug of AUDIO/VIDEO jack
(75 terminated)
Measuring Instrument
Specified Value
Oscilloscope
Sync level: A = 286 18mV (NTSC)
A = 300 18mV (PAL)
Burst level: B = 286 18mV (NTSC)
B = 300 18mV (PAL)
Adjusting method:
Order Page Address Data
1
2
3
4
0
3
01
0C
Procedure
01
02
11
6
7
0C
00
01
00
Note3: For the bit values, refer to 6-4. SERVICE MODE, 4-3. 3. Bit
value discrimination.
B
A
Fig. 6-3-6.
HDR-FX1/FX1E
6-66
Y signal
Arbitrary
Y signal: Y signal terminal of
COMPONENT OUTPUT connector
(75 terminated)
PR signal: PR signal terminal of
COMPONENT OUTPUT connector
(75 terminated)
PB signal: PB signal terminal of
COMPONENT OUTPUT connector
(75 terminated)
Measuring Instrument
Adjustment Page
Oscilloscope
C
Adjustment Address
Specified Value
82, 83, 84
Y level:
PR level:
PB level:
SYNC level:
A = 1000 10mV
B = 525 10mV
C = 525 10mV
D = E = 300 10mV
Fig. 6-3-7.
PR signal
Note: When the component video signals are not outputted, connect the
SW terminal (Pin q;) of the COMPONENT OUTPUT connector to
GND.
Switch setting:
REC FORMAT (IN/OUT REC menu) ......................... HDV1080i
DISP OUTPUT (OTHERS menu) ............................ LCD PANEL
B
E
Adjusting method:
H
0
8
10
01
01
04
4
5
10
00
82
82
Fig. 6-3-8.
PB signal
C
E
9
10
83
11
83
Fig. 6-3-9.
12
13
14
84
15
84
16
17
10
01
18
19
8
0
01
10
00
00
20
01
00
HDR-FX1/FX1E
6-67
3-5.
Recording
600
Audio oscillator
MIC/LINE
Left
Right
Attenuator
Playback
Main unit
TV monitor
Video (Yellow)
Left (White)
AUDIO/
VIDEO
47k
Right
(Red)
47k
47k (1-249-437-11)
Camera E-E
Main unit
Audio oscillator
600
MIC/LINE
Left
Left (White)
Attenuator
Right
AUDIO/
VIDEO
47k
Right
(Red)
47k
47k (1-249-437-11)
Fig. 6-3-10.
HDR-FX1/FX1E
6-68
Measurement Point
Measuring Instrument
Specified Value
Alignment tape:
For audio operation check
(XH5-3 (NTSC))
(XH5-3P (PAL))
Audio left or right terminal of
AUDIO/VIDEO jack
Signal
Measuring Instrument
Specified Value
Measurement Point
Checking Method:
1) Check that the DC voltage of the left and right terminal of
MIC/LINE jack is 2Vdc to 3Vdc. (Do not connect the audio
oscillator and attenuator.)
2) Input the 1kHz, -62dBs signal in the left and right terminal of
MIC/LINE jack
3) Check that the 1kHz signal level is the specified value.
4) Input the 70Hz, -60dBs signal in the left and right terminal of
MIC/LINE jack
5) Check that the 70Hz signal level is the specified value.
6) Set WIND menu (AUDIO SET menu) to ON.
7) Check that the 70Hz signal level is -6dB from the signal level
during WIND OFF.
8) Set WIND menu to OFF.
Measurement Point
Measuring Instrument
Specified Value
Switch setting:
MIC/LINE( AUDIO SET menu) ............................................ MIC
WIND (AUDIO SET menu) .................................................... OFF
AUDIO SELECT .......................................................... MANUAL
AUDIO LEVEL .......................... Position set by 2. Overall Level
Characteristics Check
Checking Method:
1) Check that the playback signal level is the specified value.
Signal
Switch setting:
MIC/LINE( AUDIO SET menu) ........................................... LINE
AUDIO SELECT .......................................................... MANUAL
Checking Method:
1) Input the 1kHz, -6.0dBs signal in the left and right terminal of
MIC/LINE jack
2) Push STATUS CHECK button and display level meters.
3) Turn AUDIO LEVEL knob from 0 position, little by little,
until the level meter which shows smoller level displays
12dB.
4) Record the signal.
5) Playback the recorded section.
6) Check that the 1kHz signal level is the specified value.
Measurement Point
Measuring Instrument
Specified Value
Switch setting:
MIC/LINE( AUDIO SET menu) ........................................... LINE
AUDIO SELECT .......................................................... MANUAL
AUDIO LEVEL .......................... Position set by 2. Overall Level
Characteristics Check
Checking Method:
1) Check that the DC voltage of the left and right terminal of
MIC/LINE jack is 0Vdc. (Do not connect the audio oscillator
and attenuator.)
2) Input the 70Hz, -6dBs signal in the left and right terminal of
MIC/LINE jack
3) Check that the 70Hz signal level is the specified value.
4) Input the 1kHz, -6dBs signal in the left and right terminal of
MIC/LINE jack
5) Check that the 1kHz signal level is the specified value.
6) Input the 20kHz, -6dBs signal in the left and right terminal of
MIC/LINE jack
7) Check that the 20kHz signal level is the specified value.
HDR-FX1/FX1E
6-69
Page
Data
Address
Fig. 6-4-1
3)
Hexadecimal
0 1 2 3 4 5 6 7 8 9 A B C D E F
notation
LCD Display
0 1 2 3 4 5 6 7 8 9 A b c d E F
Decimal notation
conversion value 0 1 2 3 4 5 6 7 8 9 1011 12 1314 15
4)
HDR-FX1/FX1E
6-70
4-2.
DATA PROCESS
A
(A)
B
( b)
C
(c)
D
(d)
E
( E)
F
( F)
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
Upper digit
of hexadecimal
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
A (A)
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
B (b)
176
179
180
181
182
183
184
185
186
187
188
189
190
191
192
177
193
178
C (c)
194
195
196
197
198
199
200
201
202
203
204
205
206
207
D (d)
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
E (E)
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
F (F)
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
Note: The characters shown in the parenthesis ( ) shown the display on the adjustment remote commander.
(Example) If the DDS display or the adjustment remote commander shows BD (bd);
Because the upper digit of the adjustment number is B (b), and the lower digit is D (d), the meeting point
189 of 1 and 2 in the above table is the corresponding decimal number.
Table. 6-4-1.
HDR-FX1/FX1E
6-71
4-3.
SERVICE MODE
Code
00
10
11
22
23
Function
Normal
Forced camera power ON (CAMERA-TAPE mode)
Forced VTR power ON (PLAY/EDIT mode)
Forced camera + VTR power ON
24
30
40
42
Before setting the data , select page: 0, address: 01, and set data: 01.
For page A, the data set is recorded in the non-volatile memory
by pressing the PAUSE button of the adjustment remote
commander. In this case, take note that the test mode will not be
exited even when the main power is turned off.
After completing adjustments/repairs, be sure to return the data
of this address to 00, and press the PAUSE button of the adjustment
remote commander.
Select page: 0, address: 01, and set data: 00.
2. Emergence Memory Address (Mechanism section)
Page C
Address F4 to FF
Address
Contents
F4
EMG code when first error occurs
Upper: MSW code when shift starts when first
F6
error occurs
Lower: MSW code when first error occurs
Lower: MSW code to be moved when first error
F7
occurs
F8
EMG code when second error occurs
Upper: MSW code when shift starts when second
FA
error occurs
Lower: MSW code when second error occurs
Lower: MSW code to be moved when second error
FB
occurs
FC
EMG code when last error occurs
Upper: MSW code when shift starts when last error
FE
occurs
Lower: MSW code when last error occurs
Lower: MSW code to be moved when last error
FF
occurs
When no error occurs in this unit, data 00 is written in the above
addresses (F4 to FF). when first error occurs in the unit, the data
corresponding to the error is written in the first emergency address
(F4 to F7). In the same way, when the second error occurs, the data
corresponding to the error is written in the second emergency address
(F8 to FB). Finally, when the last error occurs, the data corresponding
to the error is written in the last emergency address (FC to FF).
Note: After completing adjustments, be sure to initialize the data of
addresses F4 to FF to 00.
Initializing method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 37, and press the PAUSE
button.
3) Check that the data of page:3, address:02 is 00.
4) Select page: 0, address: 01, and set data: 00.
HDR-FX1/FX1E
6-72
Emergency Type
No error
Loading motor emergency during loading
Loading motor emergency during unloading
T reel emergency during normal rotation
S reel emergency during normal rotation
T reel emergency (Short circuit between S reel
terminal and T reel terminal)
FG emergency at the start up of the capstan
FG emergency at the start up of the drum
FG emergency during normal rotation of the drum
Mechanical Position
UNLOAD
BL
EJ
LOAD
ULE
BL
SR
BL
HL
BL
STOP
BL
R/P
1 1 0 0 = C
1 1 1 0 = E
1 0 0 0 = 8
1 1 1 0 = E
1 0 1 0 = A
1 1 1 0 = E
0 0 1 0 = 2
1 1 1 0 = E
0 1 1 0 = 6
1 1 1 0 = E
0 1 0 0 = 4
A (MSB)
B
C
D (LSB) (Fixed at 0)
Lock released
Cassette compartment
Position
Code
EJ
BL
ULE
SR
HL
2
A
STOP
R/P
NULL
0
F
Contents
Position at which the cassette component lock is released, at the farthest unload side mechanically
at which the mechanism can move no further in the UNLOAD direction.
BLANK code, at the boundary between codes.
EJECT completion position. when the cassette is ejected, the mechanism will stop at this position.
Cassette IN standby. The guide will start protruding out as the mechanism moves towards the
LOAD position.
Position at which it is possible to release the S ratchet.
Guide loading are performed here.
Stop position in the loading state. The pinch roller separates, the tension regulator returns, and the
brake is imposed on both reels.
PB, REC, CUE, REVIEW, PAUSE, FF, REW positions. When pinch roller is pressed, and the tension
regulator is ON, the mechanism is operating at this position in modes in which normal images are
shown.
Code not existing in the MD. Default value.
Status before finding any mechanism position.
HDR-FX1/FX1E
6-73
Display on the
adjustment
remote
commander
0
1
2
3
4
5
6
7
8
A
9
A (A)
B (b)
C (c)
D (d)
E (E)
B
F (F )
Address
Page
bit3
or
bit7
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
Bit values
bit2
bit1
or
or
bit6
bit5
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
bit0
or
bit4
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Address 81
Bit
0
1
3
4
5
Function
POWER SW (XVTR ON SW) (PS5610 block S101)
POWER SW (XCAM ON SW) (PS5610 block S102)
EJECT SW (XEJECT SW) (FP-965 flexible S650)
CC DOWN SW (Mechanism chassis)
DISPLAY/BATTERY INFO SW (XBATT INFO SW)
(FK-090 block S602)
Using method:
1) Select page: 2, address: 81.
2) By discriminating the bit value of display data, the state of the switch can be discriminated.
5. Switch check (2)
Page 7
Address 4F
Bit
4
Function
REC PROOF SW (Mechanism chassis)
Using method:
1) Select page: 7, address: 4F.
2) By discriminating the bit value of display data, the state of the switch can be discriminated.
6. Switch check (3)
Page 7
Address F3
Bit
2
3
Function
S jack (JK-274 board J102)
AUDIO/VIDEO jack (JK-274 board J103)
Using method:
1) Select page: 7, address: F3.
2) By discriminating the bit value of display data, the state of the switch can be discriminated.
HDR-FX1/FX1E
6-74
Address F5
Bit
0
1
2
Function
COMPONENT OUT connector (JK-274 board CN101)
MIC/LINE jack (JK-274 board J101)
Headphone jack (PS5610 block J102)
Using method:
1) Select page: 7, address: F5.
2) By discriminating the bit value of display data, the state of the switch can be discriminated.
8. Switch check (5)
Page 7
Address 5C to 5F, 60 to 6D
Using method:
1) Select page: 7, address: 5C to 5F, 60 to 6D.
2) By discriminating the display data, the pressed key can be discriminated.
Example: If the data of address: 60 is 00 and .the data of address: 61 is 09, the data of KEY AD0 signal is 0009. It can be
discriminated that the STOP button is pressed.
Address
60 (Upper digits)
61 (Lower digits)
(KEY AD0)
(IC8009 <zc. )
62 (Upper digits)
63 (Lower digits)
(KEY AD1)
(IC8009 <zv/ )
64 (Upper digits)
65 (Lower digits)
(KEY AD2)
(IC8009 <zvz )
66 (Upper digits)
67 (Lower digits)
(KEY AD3)
(IC8009 <zvx )
68 (Upper digits)
69 (Lower digits)
(KEY AD4)
(IC8009 <zvc )
6A (Upper digits)
6B (Lower digits)
(KEY AD5)
(IC8009 <zvv )
6C (Upper digits)
6D (Lower digits)
(KEY AD6)
(IC8009 <zvb )
5C (Upper digits)
5D (Lower digits)
(KEY AD7)
(IC8009 <zcm )
5E (Upper digits)
5F (Lower digits)
(KEY AD8)
(IC8009 <zc, )
Data (4 digits)
0000
006C
00D8
014C
01DC
(0000 to 0035) (0036 to 00A2) (00A3 to 0113) (0114 to 0196) (0197 to 0230)
STOP
REW
REC
PLAY
FF
(FK-090
(FK-090
(FK-090
(FK-090
(FK-090
board)
board)
board)
board)
board)
(S009)
(S021)
(S005, 018)
(S007)
(S004)
VOLUME + VOLUME - LCD BRIGHT + LCD BRIGHT(FK-090
(FK-090
(FK-090
(FK-090
board)
board)
board)
board)
(S010)
(S011)
(S014)
(S013)
EXPAND
ZERO SET DATA CODE
END
FOCUS
MEMORY
(FK-090
SEARCH
(CF5610 block)
(FK-090 board)
board)
(FK-090 board)
(S022)
(S001)
(S001)
(S016)
START/STOP REC START/
(PS5610
STOP
block)
(ZS-5610 block)
(S103)
(S003)
EXEC
PICTURE
P-MENU
MENU
STATUS
(SELECT
PROFILE
(MK-017
(MK-017
CHECK
DIAL UNIT) (MK-017 board)
board)
board)
(MK-017 board)
(S107)
(S109)
(S108)
(S102)
ASSIGN 1
ASSIGN 2
ASSIGN 3 AUTO WHT
(CK-143
(CK-143
(CK-143
BAL
board)
board)
board)
(CK-143 board)
(S201)
(S202)
(S203)
(S204)
SHOT TRANS
SHOT
SHOT
(STORE/CHECK/ TRANS A
TRANS B
EXEC)
(FP-961
(FP-961
(FP-961 flexible) flexible)
flexible)
(S611)
(S613)
(S615)
IRIS
GAIN
SHUTTER WHT BAL
(FP-966
(FP-966
SPEED
(FP-966
flexible)
flexible)
(FP-966 flexible)
flexible)
(S660)
(S661)
(S662)
(S663)
BACK LIGHT SPOT LIGHT
REC
(FP-961
(FP-961
REVIEW
flexible)
flexible)
(FP-961 flexible)
(S612)
(S614)
(S610)
HDR-FX1/FX1E
6-75
0280
(0231 to 02E1)
SLOW
(FK-090
board)
(S012)
PAUSE
(FK-090
board)
(S003)
BARS
(FK-090
board)
(S015)
033C
(02E2 to 039F)
PANEL
CLOSE
(FP-967 flexible)
(IC670, 671)
PANEL
REVERSE
(SW-433 board)
(S801)
LCD BACK
LIGHT ON
(FK-090 board)
(S019)
03FC
(03A0 to 03FF)
PANEL
OPEN
(FP-967 flexible)
(IC670, 671)
PANEL
NORMAL
(SW-433 board)
(S801)
LCD BACK
LIGHT OFF
(FK-090 board)
(S019)
No key input
ZEBRA ON PEAKING
ZEBRA/
(MK-017
ON
PEAKING OFF
board)
(MK-017 board) (MK-017 board)
(S105)
(S105)
(S105)
FOCUS
FOCUS
FOCUS
INFINITY AUTO/PUSH AUTO MANUAL
(CK-143 board) (CK-143 board) (CK-143 board)
(S206)
(S206, 205)
(S206)
GAIN L
GAIN H
GAIN M
(FP-963
(FP-963
(FP-963
flexible)
flexible)
flexible)
(S631)
(S631)
(S631)
AUTO LOCK AUTO LOCK AUTO LOCK
AUTO
HOLD
MANUAL
(FP-966 flexible) (FP-966 flexible) (FP-966 flexible)
(S664)
(S664)
(S664)
WHT
WHT
WHT
B
PRESET
A
(FP-963 flexible) (FP-963 flexible) (FP-963 flexible)
(S630)
(S630)
(S630)
9. LED check
Page 7
Switch setting:
POWER .................................................................. CAMERA
Using method:
1) Select page: 7, address: 01, and set data: 90.
2) Select page: 7, address: 04, and set data: 01.
3) Select page: 7, address: 00, set data: 01 and press the PAUSE button.
4) Check that the following LEDs are lit.
FRONT TALLY, REAR TALLY, iLINK HDV, iLINK DV, Mode HDV, Mode DV, SHOT TRANSITION STORE, SHOT TRANSITION
CHECK, SHOT TRANSITION EXEC, CHARGE
5) Select page: 7, address: 01, and set data: 90.
6) Select page: 7, address: 04, and set data: 00.
7) Select page: 7, address: 00, set data: 01 and press the PAUSE button.
8) Select page: 7, address: 00, and set data: 00.
9) Select page: 7, address: 01, and set data: 00.
10. Record of Use check (1)
Page 7
Address A7 to A9
Note1: When replacing the drum assembly or the mechanism deck, initialize the data of address: A7 to A9.
Note2: This data will be kept even if the lithium battery (FP-959 flexible BT591) is removed.
Note3: The data of page: 0, address: 10 must be 00.
Address
Function
A7
Drum rotation
Hour (H)
A8
counted time
Hour (M)
A9
(BCD code)
Hour (L)
Remarks
100000th place digit and 10000th place digit of counted time
1000th place digit and 100th place digit of counted time
10th place digit and 1st place digit of counted time
Using method:
1) The record of use data is displayed at addresses: A7 to A9.
Initializing method:
1) Select page: 7, address: A7, set data: 00 and press the PAUSE button.
2) Select page: 7, address: A8, set data: 00 and press the PAUSE button.
3) Select page: 7, address: A9, set data: 00 and press the PAUSE button.
11. Record of Use check (2)
Page 7
Address C8 to CD
Note1: This data will be kept even if the lithium battery (FP-959 flexible BT591) is removed.
Note2: The data of page: 0, address: 10 must be 00.
Address
C8
C9
CA
CB
CC
CD
Function
User initial power Year
on date
Month
(BCD code)
Day
Final condensation Year
occurrence data
Month
(BCD code)
Day
Remarks
After setting the clock, set the date of power on next
Using method:
1) The record of use data is displayed at addresses: C8 to CD.
HDR-FX1/FX1E
6-76
Address B0 to C6
Note1: This data will be kept even if the lithium battery (FP-959 flexible
BT591) is removed.
Note2: The data of page: 0, address: 10 must be 00.
Address
B0
Self-diagnosis code
Repaired by code (Occurred 1st time) *1
B1
B2
B4
B5
B6
B8
B9
BA
BC
BD
BE
C0
C1
C2
C4
C5
C6
Using method:
1) The past self-diagnosis codes are displayed at addresses: B0 to C6. Refer to SELF-DIAGNOSIS CODE TABLE for detail of the selfdiagnosis code.
Initializing method:
1) Select page: 7, address: 01, and set data: C0.
2) Select page: 7, address: 00, set data: 01 and press the PAUSE button.
3) Check that the data of page: 7, address: B0 to C7 are 00.
4) Select page: 7, address: 00, and set data: 00.
5) Select page: 7, address: 01, and set data: 00.
HDR-FX1/FX1E
6-77
Self-diagnosis Code
Block
Detailed
Function
Code
Symptom/State
Correction
C
C
C
C
0
2
2
3
4
1
2
1
0
0
0
1
0
0
0
0
C
C
3
3
1
1
2
2
0
1
C
C
C
C
C
C
3
3
3
3
3
3
1
1
1
1
1
1
2
2
2
3
4
4
2
3
4
0
0
2
T reel fault.
S reel fault.
T reel fault.
HDR-FX1/FX1E
6-78
FOR
HDR-FX1/FX1E
Take a copy of CAMERA COLOR
REPRODUCTION FRAME with
a clear sheet for use.
HDR-FX1/FX1E
HDR-FX1/FX1E
6-79
FOR
HDR-FX1/FX1E
Take a copy of CAMERA COLOR
REPRODUCTION FRAME with
a clear sheet for use.
HDR-FX1/FX1E
HDR-FX1/FX1E
6-80E
HDR-FX1/FX1E
RMT-840
SECTION 6
ADJUSTMENTS
ADJ
SERVICE MANUAL
Ver. 1.4 2007. 09
This SUPPLEMENT-3 is the revised version
of SUPPLEMENT-2.
Replace the SUPPLEMENT-2 (9-876-770-89)
with the SUPPLEMENT-3.
SUPPLEMENT-3
File this supplement-3 with the service manual.
(DI07-141)
Subject :
Correction of Adjustments
HDR-FX1/FX1E
9-876-770-8C
2007I0800-1
2007.09
Published by Kohda TEC
1.
Before starting adjustment
1-1. Adjusting items when replacing main parts and boards.
Adjusting items when replacing main parts
Page
: Added portion
Before change
Replaced parts
Parts replacement
Adjustment
Section
Adjustment
Initialization of
8,9,A,B,C,D,E,F,13,
14,18,19,1A,1B,1C,
1D,1E,1F page data
Table. 6-1-1(1).
6-2
After change
Replaced parts
Parts replacement
Adjustment
Section
Adjustment
Initialization of
8,9,A,B,C,D,E,F,13,
14,18,19,1A,1B,1C,
1D,1E,1F page data
*3
*2
*1
Table. 6-1-1(1).
Added contents
*1: When the camera control microprocessor is replaced, check that the data of page: 1E, address: D7 is the initial value. If
not, change the data to the initial value. (Refer to Table 6-1-17. 1E Page Table.)
6-3
*2: When the SP (LSI) control microprocessor is replaced, check that the fixed data are corresponding to the version of the
microprocessor. (Refer to 1-2-3. Initialization of 9, 1D page data.)
*3: When the Mechanism control microprocessor is replaced, check that the fixed data are corresponding to the version of
the microprocessor. (Refer to 1-2-2. Initialization of 8, C, 13, 18, 1C page data.)
HDR-FX1/FX1E
: Changed portion
Before change
: Added portion
After change
Page 6-7
1-1.
1-1-3. Precaution
1. Setting the Switch
10. MENU settings
CAMERA SET menu
STEADY SHOT ....................................................... OFF
IN/OUT REC. menu
REC FORMAT .............................................. HDV1080i
COMPONENT ....................................................... 1080i
TV TYPE .................................................................. 16:9
Page 6-8
1-2.
INITIALIZATION OF 8, 9, A, B, C, D, E, F, 13,
14, 18, 19, 1A, 1B, 1C, 1D, 1E, 1F PAGE DATA
Initial value
00 to 0F
10
11 to 17
18
19 to 2E
2F
30
31
32 to FF
00
Remark
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-2.
Address
00 to 0F
10
11 to 17
18
19 to 2E
2F
30
31
32 to CF
D0
D1
D2
D3 to D4
D5
D6
D7
D8
D9
DA to FF
Initial value
00
Remark
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-2.
Page 6-9
5. D Page Table
Address
Remark
33
Fixed data-2
34 to 56 Fixed data-1
57
Fixed data-2
Table. 6-1-4.
Address
33
34 to 44
45
46 to 56
57
Remark
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Table. 6-1-4.
HDR-FX1/FX1E
: Changed portion
Before change
: Added portion
After change
Page 6-9
6. 1A Page Table
Address
Remark
Address
D9
Fixed data-2
DA to D0 Fixed data-1
DE
Fixed data-2
Remark
D9
Fixed data-2
DA to DD Fixed data-1
DE
Fixed data-2
Table. 6-1-5.
Table. 6-1-5.
Page 6-10
Note:
0
3
10
FF
00
Procedure
Set the data.
The data shows the version of the
mechanism control
microprocessor.
10: Ver. 1.0 (MP1)
20: Ver. 2.0 (MP2)
1
2
0
3
10
FF
00
Note: For PAL model, the S VIDEO out Y/chroma level adjustment
addresses are changed by the version of the mechanism control
microprocessor. (Refer to 4. C Page Table.)
Page 6-11
3. 8 Page Table
Note1: The data of page: 0, address: 10 must be 00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,
13, 18, 1C Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,
13, 18, 1C Page Data).
Address
00 to 7D Fixed data-1
Remark
3. 8 Page Table
3-1. 8 Page Table (Mechanism Control Microprocessor
Version 1.0 (MP1) to Version 3.0 (MP3))
Note1: The data of page: 0, address: 10 must be 00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,
13, 18, 1C Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,
13, 18, 1C Page Data).
Address
00 to 7D Fixed data-1
D4 to FF Fixed data-1
Table. 6-1-6.
Remark
D4 to FF Fixed data-1
HDR-FX1/FX1E
: Changed portion
: Added portion
: Deleted portion
Page 6-11
3-2. 8 Page Table (Mechanism Control Microprocessor
Version 4.0 (MP4))
Address
00 to 7D
7E
7F to 83
84
85 to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Initial value
00 to 84
85
86 to FF
Remark
Fixed data-1
Fixed data (Note3)
Fixed data-1
50
Address
00 to FF Fixed data-1
Remark
After change
Page 6-11, 6-12
4. C Page Table
Note1: The data of page: 0, address: 10 must be 00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,
13, 18, 1C Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,
13, 18, 1C Page Data).
Note3: PAL model with the version 1.0 mechanism control
microprocessor, or NTSC model.
Note4: PAL model with the version 2.0 mechanism control
microprocessor. (Refer to 2. Modification of 8, C, 13, 18, 1C
Page Data for version check of the mechanism control
microprocessor (VC-367 board IC8801).).
Remark
4. C Page Table
4-1. C Page Table (Mechanism Control Microprocessor
Version 1.0 (MP1))
Note1: The data of page: 0, address: 10 must be 00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,
13, 18, 1C Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,
13, 18, 1C Page Data).
25
26
27
70
2A
2A
70
2A
2A
25
26
27
85
86
87
88 to F3
70
2A
2A
70
2A
2A
85 to F3
70
2A
2A
70
2A
2A
Remark
Table. 6-1-7.
HDR-FX1/FX1E
Page 6-12
4-2. C Page Table (Mechanism Control Microprocessor
Version 2.0 (MP2) to Version 3.0 (MP3))
Note1: The data of page: 0, address: 10 must be 00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,
13, 18, 1C Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,
13, 18, 1C Page Data).
Note3: For PAL model, when the mechanism control microprocessor is
replaced, check that the data of address: 85 to 87 is other than
00. If not, perform S VIDEO out Y level adjustment and S
VIDEO out chroma level adjustment.
Remark
Fixed data-1
CAP FG duty adj.
Fixed data-1
S VIDEO out Y level adj. (NTSC)
S VIDEO out chroma level adj.
(NTSC)
Fixed data-1
Backlight adj. (EVF)
VCO adj. (EVF)
VCOM level adj. (EVF)
RGB AMP adj. (EVF)
Fixed data-1
PSIG level adj. (EVF)
White balance adj. (EVF)
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Contrast adj.(HD) (LCD)
Contrast adj. (EVF)
Fixed data-1
COMPONENT OUTPT level adj.
HDR-FX1/FX1E
Page 6-12
4-3. C Page Table (Mechanism Control Microprocessor
Version 4.0 (MP4) to Version 8.0 (MP8))
Note1: The data of page: 0, address: 10 must be 00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,
13, 18, 1C Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,
13, 18, 1C Page Data).
Note3: For PAL model, when the mechanism control microprocessor is
replaced, check that the data of address: 85 to 87 is other than
00. If not, perform .S VIDEO out Y level adjustment and S
VIDEO out chroma level adjustment.
Note4: When the mechanism control microprocessor is replaced, check
that the data of the fixed data address shown in the table is the
initial value. If not, change the data to the initial value.
Remark
Fixed data-1
CAP FG duty adj.
Fixed data-1
S VIDEO out Y level adj. (NTSC)
S VIDEO out chroma level adj.
(NTSC)
Fixed data-1
Backlight adj. (EVF)
Remark
COMPONENT OUTPT level adj.
HDR-FX1/FX1E
: Changed portion
Before change
: Added portion
After change
Page 6-12
5. 13 Page Table
Note1: When reading or writing the 13 page data, select page: 0, address:
10, and set data: 01, then select 8 page. The 13 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,
13, 18, 1C Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,
13, 18, 1C Page Data).
Address
Initial value
00 to 03
04
05
06
07
08
09
0A
0B
0C to 12
13
14 to 24
25
26 to FF
08
00
46
01
02
00
00
00
Remark
5. 13 Page Table
5-1. 13 Page Table (Mechanism Control Microprocessor
Version 1.0 (MP1) to Version 2.0 (MP2))
Note1: When reading or writing the 13 page data, select page: 0, address:
10, and set data: 01, then select 8 page. The 13 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,
13, 18, 1C Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,
13, 18, 1C Page Data).
Note3: When the 13 page data has been initialized, check that the data of
the fixed data address shown in the table is the initial value. If not,
change the data to the initial value.
Address
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-8.
00 to 03
04
05
06
07
08
09
0A
0B
0C to 12
13
14 to 24
25
26 to DE
DF
E0 to E8
E9
EA
EB
EC
ED to FF
Initial value
08
00
46
01
02
00
00
00
C5
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data (Note3)
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
HDR-FX1/FX1E
Page 6-12
5-2. 13 Page Table (Mechanism Control Microprocessor
Version 3.0 (MP3))
Note1: When reading or writing the 13 page data, select page: 0, address:
10, and set data: 01, then select 8 page. The 13 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,
13, 18, 1C Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,
13, 18, 1C Page Data).
Note3: When the mechanism control microprocessor is replaced, check
that the data of the fixed data address shown in the table is the
initial value. If not, change the data to the initial value.
Note1: When reading or writing the 13 page data, select page: 0, address:
10, and set data: 01, then select 8 page. The 13 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,
13, 18, 1C Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,
13, 18, 1C Page Data).
Note3: When the mechanism control microprocessor is replaced, check
that the data of the fixed data address shown in the table is the
initial value. If not, change the data to the initial value.
Address
Address
Initial value
00 to 03
04
05
06
07
08
09
0A
0B
0C to 12
13
14 to 24
25
26 to 89
8A
8B
8C to B6
B7
B8
B9
BA to DA
DB
DC
DD
DE
DF to E8
E9
EA to FF
08
00
46
01
02
00
00
00
55
61
0C
60
60
05
01
05
05
81
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data (Note3)
Fixed data-1
Fixed data (Note3)
Fixed data-1
Fixed data (Note3)
Fixed data-1
Fixed data (Note3)
Fixed data-1
00 to 03
04
05
06
07
08
09
0A
0B
0C to 12
13
14 to 24
25
26 to 89
8A
8B
8C to B6
B7
B8
B9
BA to DA
DB
DC
DD
DE
DF to E8
E9
EA to ED
EE
EF to FF
Initial value
08
00
46
01
02
00
00
00
55
61
0C
60
60
05
01
05
05
81
80
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data (Note3)
Fixed data-1
Fixed data (Note3)
Fixed data-1
Fixed data (Note3)
Fixed data-1
Fixed data (Note3)
Fixed data-1
Fixed data (Note3)
Fixed data-1
HDR-FX1/FX1E
Page 6-12
5-4. 13 Page Table (Mechanism Control Microprocessor
Version 6.0 (MP6) to Version 8.0 (MP8))
Note1: When reading or writing the 13 page data, select page: 0, address:
10, and set data: 01, then select 8 page. The 13 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,
13, 18, 1C Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,
13, 18, 1C Page Data).
Note3: When the mechanism control microprocessor is replaced, check
that the data of the fixed data address shown in the table is the
initial value. If not, change the data to the initial value.
Refer to 1. Initialization of 8, C, 13, 18, 1C page data for the
version check of the mechanism control microprocessor.
Address
Initial value
00 to 03
04
05
06
07
08
09
0A
0B
0C to 12
13
14 to 24
25
26 to 89
8A
8B
8C to B6
B7
B8
B9
0C
60
60 or 78
BA to BD
BE
00 or 01
BF to D5
08
00
46
01
02
00
00
00
55
61
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data (Note3)
Fixed data-1
Fixed data (Note3)
Fixed data (Note3)
60: Mechanism control microprocessor
Ver. 6.0 (MP6)
78: Mechanism control microprocessor
Ver. 7.0 (MP7) or Ver. 8.0 (MP8)
Fixed data-1
Fixed data (Note3)
00: Mechanism control microprocessor
Ver. 6.0 (MP6) or Ver. 7.0 (MP7)
01: Mechanism control microprocessor
Ver. 8.0 (MP8)
Fixed data-1
Address
Remark
Initial value
D6
00 or 3C
Fixed data (Note3)
00: Mechanism control microprocessor
Ver. 6.0 (MP6) or Ver. 7.0 (MP7)
3C: Mechanism control microprocessor
Ver. 8.0 (MP8)
D7
00 or 0A
Fixed data (Note3)
00: Mechanism control microprocessor
Ver. 6.0 (MP6)
0A:Mechanism control microprocessor
Ver. 7.0 (MP7) or Ver. 8.0 (MP8)
D8
00 or 3C
Fixed data (Note3)
00: Mechanism control microprocessor
Ver. 6.0 (MP6)
3C: Mechanism control microprocessor
Ver. 7.0 (MP7) or Ver. 8.0 (MP8)
D9
00 or 1E
Fixed data (Note3)
00: Mechanism control microprocessor
Ver. 6.0 (MP6)
1E: Mechanism control microprocessor
Ver. 7.0 (MP7) or Ver. 8.0 (MP8)
DA
Fixed data-1
DB
1E or 1D
Fixed data (Note3)
1E: Mechanism control microprocessor
Ver. 6.0 (MP6)
1D:Mechanism control microprocessor
Ver. 7.0 (MP7) or Ver. 8.0 (MP8)
DC
11 or 15
Fixed data (Note3)
11: Mechanism control microprocessor
Ver. 6.0 (MP6)
15: Mechanism control microprocessor
Ver. 7.0 (MP7) or Ver. 8.0 (MP8)
DD
1E
Fixed data (Note3)
DE
1E
DF to E8
Fixed data-1
E9
81
Fixed data (Note3)
EA to ED
Fixed data-1
EE
80
Fixed data (Note3)
EF to FF
Fixed data-1
HDR-FX1/FX1E
10
: Changed portion
Before change
: Added portion
After change
Page 6-12
6. 18 Page Table
Note1: When reading or writing the 18 page data, select page: 0, address:
10, and set data: 01, then select 8 page. The 18 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,
13, 18, 1C Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,
13, 18, 1C Page Data).
Address
00 to 5D Fixed data-1
5E
Fixed data-2
5F to FF Fixed data-1
Remark
Table. 6-1-9.
6. 18 Page Table
6-1. 18 Page Table (Mechanism Control Microprocessor
Version 1.0 (MP1) to Version 2.0 (MP2))
Note1: When reading or writing the 18 page data, select page: 0, address:
10, and set data: 01, then select 8 page. The 18 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,
13, 18, 1C Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,
13, 18, 1C Page Data).
Address
00 to 38
39
3A
3B
3C
3D to 5D
5E
5F
60
61
62
63 to FF
Remark
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Address
00 to 07
08
09
0A
0B
0C
0D to 76
77
78
79 to 7A
7B
7C
79 to FF
Initial value
96
36
30
38
58
01
40
03
40
Remark
Fixed data-1
Fixed data (Note3)
Fixed data-1
Fixed data (Note3)
Fixed data-1
HDR-FX1/FX1E
11
: Changed portion
Before change
: Added portion
After change
Page 6-12
7. 1C Page Table
Note1: When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,
18, 1C Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,
18, 1C Page Data).
Address
Initial value
Remark
7. 1C Page Table
7-1. 1C Page Table (Mechanism Control Microprocessor
Version 1.0 (MP1) to Version 2.0 (MP2))
Note1: When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,
13, 18, 1C Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,
13, 18, 1C Page Data).
Address
5F to 66
67
68 to 69
6A
6B to B2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-10.
5F
60
61
62 to 66
67
68
69
6A
6B to B2
Initial value
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
HDR-FX1/FX1E
12
Page 6-13
7-2. 1C Page Table (Mechanism Control Microprocessor
Version 3.0 (MP3))
Note1: When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,
13, 18, 1C Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,
13, 18, 1C Page Data).
Note3: When the mechanism control microprocessor is replaced, check
that the data of the fixed data address shown in the table is the
initial value. If not, change the data to the initial value.
Address
Initial value
00 to 42
43
44 to 46
47
48
49
4A to 4D
4E
4F
50
51
52
53
54
55
56
57
58
59 to 5D
5E
5F
60
61
62 to 66
67
68
69
6A
6B
6C
6D to B2
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Address
Remark
Initial value
B3
00
Error rate check
B4
00
B5
00
B6
00
B7
00
B8
80
B9
00
BA
00
BB
00
BC
00
BD
00
BE
00
BF
00
C0
00
C1
00
C2
00
C3
80
C4
00
C5
00
C6
00
C7
00
C8
00
C9 to FB
Fixed data-1
FC
Fixed data-2
FD to FF
Fixed data-1
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
5C
07
HDR-FX1/FX1E
13
Page 6-13
7-3. 1C Page Table (Mechanism Control Microprocessor
Version 4.0 (MP4))
Note1: When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,
13, 18, 1C Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,
13, 18, 1C Page Data).
Note3: When the mechanism control microprocessor is replaced, check
that the data of the fixed data address shown in the table is the
initial value. If not, change the data to the initial value.
Address
Initial value
00 to 42
43
44 to 46
47
48
49
4A to 4D
4E
4F
50
51
52
53
54
55
56
57
58
59 to 5D
5E
5F
60
61
62 to 66
67
68
69
6A
6B
6C
6D
6E
6F to B2
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Address
Remark
Initial value
B3
00
Error rate check
B4
00
B5
00
B6
00
B7
00
B8
80
B9
00
BA
00
BB
00
BC
00
BD
00
BE
00
BF
00
C0
00
C1
00
C2
00
C3
80
C4
00
C5
00
C6
00
C7
00
C8
00
C9 to FB
Fixed data-1
FC
Fixed data-2
FD to FF
Fixed data-1
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
5C
07
DE
1A
Fixed data-1
HDR-FX1/FX1E
14
: Added portion
Page 6-13
7-4. 1C Page Table (Mechanism Control Microprocessor
Version 5.0 (MP5) to Version 8.0 (MP8))
Note1: When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: Fixed data-1: Initialized data. (Refer to 1. Initializing the 8, C,
13, 18, 1C Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 8, C,
13, 18, 1C Page Data).
Note3: When the mechanism control microprocessor is replaced, check
that the data of the fixed data address shown in the table is the
initial value. If not, change the data to the initial value.
Address
00 to 6A
6B
6C
6D
6E
6F to B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9 to FF
Initial value
5C
07
DE
1A
00
00
00
00
00
80
00
00
00
00
00
00
00
00
00
00
80
00
00
00
00
00
Remark
Fixed data-1
Fixed data (Note3)
Fixed data-1
Error rate check
Fixed data-1
After change
Page 6-13
1-2-3.
1-2-3.
HDR-FX1/FX1E
15
: Changed portion
Before change
: Added portion
After change
Page 6-13
4. 1D Page Table
Note1: When reading or writing the 1D page data, select page: 0, address:
10, and set data: 01, then select D page. The 1D page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: The data of page: 0, address: 10 must be 00.
Note3: Fixed data-1: Initialized data. (Refer to 1. Initializing the 9, 1D
Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 9, 1D
Page Data).
Address
00 to FF Fixed data-1
Remark
Table. 6-1-12.
4. 1D Page Table
4-1. 1D Page Table (SP Control Microprocessor Version
1.0 (MP1) to Version 3.0 (MP3))
Note1: When reading or writing the 1D page data, select page: 0, address:
10, and set data: 01, then select D page. The 1D page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
00.
Note2: The data of page: 0, address: 10 must be 00.
Note3: Fixed data-1: Initialized data. (Refer to 1. Initializing the 9, 1D
Page Data.)
Fixed data-2: Modified data. (Refer to 2. Modification of 9, 1D
Page Data).
Address
00 to FF Fixed data-1
Remark
Address
00 to 2C
2D
2E
2F to F3
F4
F5 to FF
Initial value
Remark
Fixed data-1
Fixed data (Note3)
00
00
Fixed data-1
Fixed data (Note3)
Fixed data-1
B4
Address
00 to 2C
2D
2E
2F to F3
F4
F5 to FF
Initial value
E7
F9
B4
Remark
Fixed data-1
Fixed data (Note3)
Fixed data-1
Fixed data (Note3)
Fixed data-1
HDR-FX1/FX1E
16
: Changed portion
Before change
: Added portion
After change
Page 6-14
3. E Page Table
Address
00 to 17 Fixed data-1
Remark
Table. 6-1-13.
Address
00 to 14 Fixed data-1
15
Fixed data-2
16 to 17 Fixed data-1
Remark
Table. 6-1-13.
Page 6-17
6. 19 Page Table
Address
00 to 69 Fixed data-1
Remark
Table. 6-1-16.
Address
00 to 07
08
09
0A
0B to 34
35
36 to 69
Remark
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-16.
7. 1E Page Table
Note3: When the camera control microprocessor is replaced, check that
the data of the fixed data address shown in the table is the initial
value. If not, change the data to the initial value.
Address
00 to 74
75
76
77
78 to CD
CE
CF
D0 to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-17.
Address
00 to 74
75
76
77
78 to CD
CE
CF
D0 to D6
D7
D8 to FF
Initial value
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
55
Fixed data-1
Fixed data (Note3)
Fixed data-1
Table. 6-1-17.
HDR-FX1/FX1E
17
: Changed portion
Before change
After change
Page 6-34
1-3.
Subject
Filter
Measurement Point
Measuring Instrument
Specified Value 1
Specified Value 2
Specified Value 3
Clear chart
(HD color bar standard picture frame)
Filter C14 for color temperature
correction
ND filter 1.0 and 0.4 and 0.1
Video termial of
Display data of
AUDIO/VIDEO
page 1 (Note2)
jack
NTSC or PAL Adjustment remote
vectorscope
commander
Fig. 6-1-13 (A)
Fig. 6-1-13 (B)
8000 to 8B80
Page 6-35
23. White Balance Check ND 1
Subject
Clear chart
(HD color bar standard picture frame)
Filter
Measurement Point
Measuring Instrument
Specified Value 1
Specified Value 2
Specified Value 3
Subject
Filter
Measurement Point
Measuring Instrument
Specified Value 1
Specified Value 2
Specified Value 3
Clear chart
(HD color bar standard picture frame)
Filter C14 for color temperature
correction
ND filter 1.0 and 0.4 and 0.1
Video termial of
Display data of
AUDIO/VIDEO
page 1 (Note2)
jack
NTSC or PAL Adjustment remote
vectorscope
commander
Fig. 6-1-14 (A)
Fig. 6-1-14 (B)
8000 to 8B80
Page 6-36
24. White Balance Check ND 2
Subject
Clear chart
(HD color bar standard picture frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
COMPONENT connector
Measuring Instrument Vectorscope (LV5152)
Specified Value 1
Fig. 6-1-15 (A)
Specified Value 2
Fig. 6-1-15 (B)
Subject
Clear chart
(HD color bar standard picture frame)
Filter
Measurement Point
Measuring Instrument
Specified Value 1
Specified Value 2
HDR-FX1/FX1E
18
: Changed portion
Before change
After change
Page 6-41
9D
6
7
8
9
6
6
6
9E
12
12
22
80
00
10
Adjusting method:
Order Page Address Data
Procedure
1
Set REC FORMAT to DV.
2
Set ND FILTRE switch to
OFF.
3
0
01
01 Set the data.
4
6
01
4D Set the data, and press PAUSE
button.
5
6
9D
Change the data and set the Y
signal level (A) to 90 IRE
(NTSC) or 88 IRE (PAL).
(Note5) (Fig. 6-1-20.)
6
6
9E
22 Set the data.
7
6
12
80 Set the data.
8
6
12
00 Set the data.
9
Check that the Y signal level (A) is
90 IRE (NTSC) or 88 IRE (PAL).
10
Check that each center of all
color luminance points is set in
each color reproduction frame.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 .
90 IRE = 630 mV, 88 IRE = 616 mV
Page 6-42
Adjusting method:
Procedure
Procedure
Set ND FILTRE switch to 1.
01
01
01
01
01
4D
01
4D
9D
9D
9E
22
12
80
9E
22
12
80
12
00
12
00
HDR-FX1/FX1E
19
: Changed portion
Before change
After change
Page 6-42
9D
5
6
7
8
6
6
6
9E
12
12
22
80
00
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to 2.
2
0
01
01 Set the data.
3
6
01
4D Set the data, and press PAUSE
button.
4
9D
5
6
7
8
6
6
6
9E
12
12
22
80
00
Page 6-43
0
6
6
6
01
8A
9B
01
9D
7
8
9
10
6
6
6
9E
12
12
11
01
04
4D
22
80
00
Adjusting method:
Procedure
Note5: For the bit values, refer to 6-4. SERVICE MODE, 4-3. 3. Bit
value discrimination.
Note6: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 .
70 IRE = 490 mV
Procedure
Set ND FILTRE switch to OFF.
01
01
8A
04
9B
01
9D
9E
22
12
80
12
00
10
11
Note5: For the bit values, refer to 6-4. SERVICE MODE, 4-3. 3. Bit
value discrimination.
Note6: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 .
70 IRE = 490 mV, 68 IRE = 476 mV
HDR-FX1/FX1E
20
: Changed portion
Before change
After change
Page 6-44
9D
7
8
9
10
6
6
6
9E
12
12
11
22
80
00
Note4: For the bit values, refer to 6-4. SERVICE MODE, 4-3. 3. Bit
value discrimination.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 .
70 IRE = 490 mV
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to 1.
2
0
01
01 Set the data.
3
6
8A
04 Set the data.
4
6
9B
Check that bit3 is 1. (Note4)
5
6
01
4D Set the data, and press PAUSE
button.
6
6
9D
Change the data and set the Y
signal level (A) to 70 IRE (NTSC)
or 68 IRE (PAL). (Note5)
(Fig. 6-1-22.)
7
6
9E
22 Set the data.
8
6
12
80 Set the data.
9
6
12
00 Set the data.
10
Check that the Y signal level (A) is
70 IRE (NTSC) or 68 IRE (PAL).
11
Check that each center of all color
luminance points is set in each
color reproduction frame.
Note4: For the bit values, refer to 6-4. SERVICE MODE, 4-3. 3. Bit
value discrimination.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 .
70 IRE = 490 mV, 68 IRE = 476 mV
Page 6-44
36. Color Reproduction Check ND 2 SD CINE
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to 2.
2
0
01
01 Set the data.
3
6
8A
04 Set the data.
4
6
9B
Check that bit3 is 1. (Note4)
5
6
01
4D Set the data, and press PAUSE
button.
6
6
9D
Change the data and set the Y
signal level (A) to 70 IRE.
(Note5) (Fig. 6-1-22.)
7
6
9E
22 Set the data.
8
6
12
80 Set the data.
9
6
12
00 Set the data.
10
Check that the Y signal level (A)
is 70 IRE.
11
Check that each center of all
color luminance points is set in
each color reproduction frame.
Note4: For the bit values, refer to 6-4. SERVICE MODE, 4-3. 3. Bit
value discrimination.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 .
70 IRE = 490 mV
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to 2.
2
0
01
01 Set the data.
3
6
8A
04 Set the data.
4
6
9B
Check that bit3 is 1. (Note4)
5
6
01
4D Set the data, and press PAUSE
button.
6
6
9D
Change the data and set the Y
signal level (A) to 70 IRE
(NTSC) or 68 IRE (PAL).
(Note5) (Fig. 6-1-22.)
7
6
9E
22 Set the data.
8
6
12
80 Set the data.
9
6
12
00 Set the data.
10
Check that the Y signal level (A) is
70 IRE (NTSC) or 68 IRE (PAL).
11
Check that each center of all
color luminance points is set in
each color reproduction frame.
Note4: For the bit values, refer to 6-4. SERVICE MODE, 4-3. 3. Bit
value discrimination.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 .
70 IRE = 490 mV, 68 IRE = 476 mV
HDR-FX1/FX1E
21
: Changed portion
Before change
After change
Page 6-49
Camera, HDV1080i
Arbitrary
Pin 5 of CN107 of DA-033 board
(EXT DA)
Digital voltmeter
C
32, 33
NORMAL mode : A=1.00 0.05Vdc
BRIGHT mode : B=1.65 0.05Vdc
Subject
Clear chart
(HD color bar standard picture frame)
Mode
Camera, HDV1080i
Subject
Measurement Point
Arbitrary
Pin 5 of CN107 of DA-033 board
(EXT DA)
Measuring Instrument
Adjustment Page
Digital voltmeter
C
Adjustment Address
32, 33
Specified Value
HDR-FX1/FX1E
22
: Changed portion
Before change
: Added portion
After change
Page 6-50
1-4.
C
0
36
01
00
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01 Set the data.
2
C
36
Change the data and set the DC
voltage (A) to the specified value.
(The data should be 00 to 3F.)
3
C
36
Press PAUSE button.
4
0
01
00 Set the data.
Page 6-51
6. Contrast Adjustment (VC-367 board)
Mode
Camera, HDV1080i and DV
Subject
Arbitrary
Measurement Point
Pin 9 of CN107 of DA-033 board
(EVF VG)
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Oscilloscope
C
3C, 77
A = 2.57 0.05V
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Oscilloscope
C
3C, 77
A = 2.70 0.05V
: Added portion
Before change
After change
Page 6-65
3-4.
Note3: [ ]: PAL model with the version 2.0 or later mechanism control
microprocessor (VC-367 board IC8801). (Refer to 1-2-2.
INITIALIZATION OF 8, C, 13, 18, 1C PAGE DATA for version
check of the mechanism control microprocessor.)
Note3: [ ]: PAL model with the version 2.0 or later mechanism control
microprocessor (VC-367 board IC8801). (Refer to 1-2-2.
INITIALIZATION OF 8, C, 13, 18, 1C PAGE DATA for version
check of the mechanism control microprocessor.)
HDR-FX1/FX1E
23
: Changed portion
Before change
: Added portion
After change
Page 6-69
3-5.
Mode
Signal
Measurement Point
Measuring Instrument
Specified Value
Switch setting:
MIC/LINE( AUDIO SET menu) ............................................ MIC
WIND (AUDIO SET menu) .................................................... OFF
AUDIO SELECT .......................................................... MANUAL
AUDIO LEVEL .......................... Position set by 2. Overall Level
Characteristics Check
Switch setting:
REC FORMAT (IN/OUT REC menu) ......................... HDV1080i
MIC/LINE( AUDIO SET menu) ............................................ MIC
WIND (AUDIO SET menu) .................................................... OFF
AUDIO SELECT .......................................................... MANUAL
AUDIO LEVEL .......................... Position set by 2. Overall Level
Characteristics Check
Checking Method:
1) Check that the DC voltage of the left and right terminal of
MIC/LINE jack is 2Vdc to 3Vdc. (Do not connect the audio
oscillator and attenuator.)
2) Input the 1kHz, -62dBs signal in the left and right terminal of
MIC/LINE jack
3) Check that the 1kHz signal level is the specified value.
4) Input the 70Hz, -60dBs signal in the left and right terminal of
MIC/LINE jack
5) Check that the 70Hz signal level is the specified value.
6) Set WIND menu (AUDIO SET menu) to ON.
7) Check that the 70Hz signal level is -6dB from the signal level
during WIND OFF.
8) Set WIND menu to OFF.
Checking Method:
1) Check that the DC voltage of the left and right terminal of
MIC/LINE jack is 1.8Vdc to 3Vdc. (Do not connect the audio
oscillator and attenuator.)
2) Input the 1kHz, -59dBs signal in the left and right terminal of
MIC/LINE jack
3) Check that the 1kHz signal level is the specified value.
4) Input the 70Hz, -53dBs signal in the left and right terminal of
MIC/LINE jack
5) Check that the 70Hz signal level is the specified value.
6) Set WIND menu (AUDIO SET menu) to ON.
7) Check that the 70Hz signal level is -6dB from the signal level
during WIND OFF.
8) Set WIND menu to OFF.
HDR-FX1/FX1E
24
: Changed portion
Before change
: Added portion
After change
Page 6-69
Switch setting:
MIC/LINE( AUDIO SET menu) ........................................... LINE
AUDIO SELECT .......................................................... MANUAL
AUDIO LEVEL .......................... Position set by 2. Overall Level
Characteristics Check
Checking Method:
1) Check that the DC voltage of the left and right terminal of
MIC/LINE jack is 0Vdc. (Do not connect the audio oscillator
and attenuator.)
Mode
Signal
Measurement Point
Measuring Instrument
Specified Value
Switch setting:
REC FORMAT (IN/OUT REC menu) ......................... HDV1080i
MIC/LINE( AUDIO SET menu) ........................................... LINE
AUDIO SELECT .......................................................... MANUAL
AUDIO LEVEL .......................... Position set by 2. Overall Level
Characteristics Check
Checking Method:
1) Check that the DC voltage of the left and right terminal of
MIC/LINE jack is 0 0.1Vdc. (Do not connect the audio
oscillator and attenuator.)
HDR-FX1/FX1E
25
ENGLISH
JAPANESE
[Description of main button functions on toolbar of the Adobe Acrobat Reader Ver5.0 (for Windows)]
Toolbar
Printing a text
Application of printing:
To set a range to be printed within a page, select the graphic
and drag on the page to enclose a range to
selection tool
be printed, and then click the Print button.
Finding a text
1. Click the Find button
.
2. Enter a character string to be found into a text box, and click
the [Find]. (Specify the find options as necessary)
, zoom tool
or
for zoom-
Switching a page
To move to the first page, click the
Rotate
Click rotate tool
ENGLISH
JAPANESE
Reverse
987677055.pdf
Revision History
Date
1.0
2004.09
Official Release
1.1
2005.05
Supplement-1
Change of adjustments
No
1.2
2005.09
Correction-1
Correction of adjustments
S.M. correction: Page 6-4
Yes
1.3
2006.07
Supplement-2
Revision of Supplement-1
No
1.4
2007.09
Supplement-3
(DI07-141)
Revision of Supplement-2
This SUPPLEMENT-3 is the revised version
of SUPPLEMENT-2.
Replace the SUPPLEMENT-2 (9-876-77089) with the SUPPLEMENT-3.
No
HDR-FX1/FX1E
History
Contents
S.M. Rev.
issued
Ver.