Escolar Documentos
Profissional Documentos
Cultura Documentos
1.9E
Microllam® LVL
Headers
and Beams
Support heavier loads
than comparably sized
conventional glulam or
sawn lumber products
Consistent quality and
uniformity for predictable
performance
Each piece is straight,
strong, and true — resists
bowing, shrinking, and
twisting
Covered by our
Product Warranty
against manufacturing
defects for the life of
the structure
1-800-628-3997
www.trusjoist.com
Changing the Way You Build ™
2 Trus Joist • Microllam® LVL Specifier’s Guide 2020 • August 2003
Microllam® LVL
An Integral Part of the
FrameWorks® Building System
Microllam® laminated veneer lumber (LVL) is manufactured from thin
sheets of veneer structurally bonded together to make headers and
beams that span much longer distances and support heavier loads
than ordinary lumber.
Microllam® LVL headers and beams are available in the following
sizes:
Widths: 13/4" Depths: 51/2", 71/4", 91/4", 91/2", 111/4", 117/8", 14",
16", 18", and 20"
Some sizes may not be available in your region.
The long spans and impressive strength of Microllam® LVL
Contact your local Trus Joist dealer or can make a difference in any floor or roof system.
technical representative for availability.
TA B L E O F C O N T E N T S
Design Properties . . . . . . . . . . . . . . . . . . . . . . . . . 3
Headers Supporting Roof . . . . . . . . . . . . . . . . . . . 4
Ridge Beams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Headers Supporting Floor and Roof . . . . . . . . . . . 6
Floor Girder Beams . . . . . . . . . . . . . . . . . . . . . . . . 7
Load Tables: Floor and Roof . . . . . . . . . . . . . . 8 –13
Framing Connectors . . . . . . . . . . . . . . . . . . . 14 –15
Beam Details and Bearing Information . . . . . . . . 16
Multiple Member Connections . . . . . . . . . . . . . . 17
Tapered End Cuts . . . . . . . . . . . . . . . . . . . . . . . . 18
Allowable Holes . . . . . . . . . . . . . . . . . . . . . . . . . 18
Trus Joist Support Team. . . . . . . . . . . . . . . . . . . . 19
12 0.136
(1) For 12" depth. For others, multiply by [ d ]
(2) Ft has been reduced to reflect the volume effects of
General Assumptions for Microllam® LVL
length, width and thickness. • Lateral support required at bearing and 24" on-center maximum.
(3) Fc⊥ shall not be increased for duration of load. • Bearing lengths are based on Microllam® LVL’s bearing stress of 750 psi.
• No camber.
• All members 71/4" and less in depth are restricted to a maximum deflection
of 5/16".
Microllam® LVL
is intended for dry-use • Tables on pages 4–7 include reductions applied in accordance with code.
13 ⁄4"
1.9E Microllam®
LVL
Allowable Design Properties (100% Load Duration)
Depth
Design Property
51/2" 71/4" 91/4" 91/2" 111/4" 117/8" 14" 16" 18" 20"
Moment (ft-lbs) 2,125 3,555 5,600 5,885 8,070 8,925 12,130 15,555 19,375 23,580
Shear (lbs) 1,830 2,410 3,075 3,160 3,740 3,950 4,655 5,320 5,985 6,650
Moment of Inertia (in.4) 24 56 115 125 208 244 400 597 851 1,167
Weight (plf) 2.8 3.7 4.7 4.8 5.7 6.1 7.1 8.2 9.2 10.2
Sizing Tables
4 Trus Joist • Microllam® LVL Specifier’s Guide 2020 • August 2003
Ho
us Rough
g
eW Openin
idt g
h Openin
Rough
13/4" x 91/4" 13/4" x 111/4" 13/4" x 111/4" 13/4" x 14" 31/2" x 111/4" 31/2" x 14" 31/2" x 16"
36'-0"
125%
51/4" x 71/4" 31/2" x 91/4" 31/2" x 91/4" 31/2" x 91/2" 51/4" x 111/4" 51/4" x 14"
13/4" x 91/4" 13/4" x 91/4" 13/4" x 111/4" 13/4" x 117/8" 13/4" x 14" 31/2" x 117/8" 31/2" x 14"
24'-0"
31/2" x 71/4" 31/2" x 91/4" 31/2" x 91/4" 31/2" x 111/4" 51/4" x 111/4" 51/4" x 117/8"
13/4" x 91/4" 13/4" x 111/4" 13/4" x 111/4" 13/4" x 14" 31/2" x 111/4" 31/2" x 14" 31/2" x 16"
20LL + 20DL 30'-0"
51/4" x 71/4" 31/2" x 91/4" 31/2" x 91/4" 31/2" x 91/2" 51/4" x 91/2" 51/4" x 111/4" 51/4" x 14"
13/4" x 91/4" 13/4" x 111/4" 13/4" x 117/8" 31/2" x 111/4" 31/2" x 117/8" 31/2" x 14" 31/2" x 16"
36'-0"
51/4" x 71/4" 31/2" x 91/4" 31/2" x 91/4" 51/4" x 91/4" 51/4" x 111/4" 51/4" x 117/8" 51/4" x 14"
13/4" x 91/4" 13/4" x 91/4" 13/4" x 111/4" 13/4" x 14" 31/2" x 111/4" 31/2" x 117/8" 31/2" x 14"
24'-0"
31/2" x 71/4" 31/2" x 91/4" 31/2" x 91/4" 51/4" x 91/4" 51/4" x 111/4" 51/4" x 117/8"
13/4" x 91/4" 13/4" x 111/4" 13/4" x 111/4" 13/4" x 14" 31/2" x 111/4" 31/2" x 14" 31/2" x 16"
25LL + 15DL 30'-0"
51/4" x 71/4" 31/2" x 91/4" 31/2" x 91/4" 31/2" x 91/2" 51/4" x 91/2" 51/4" x 111/4" 51/4" x 14"
13/4" x 111/4" 13/4" x 111/4" 13/4" x 14" 31/2" x 111/4" 31/2" x 14" 31/2" x 14" 31/2" x 16"
36'-0"
31/2" x 91/4" 31/2" x 91/4" 31/2" x 91/4" 51/4" x 91/4" 51/4" x 111/4" 51/4" x 117/8" 51/4" x 14"
13/4" x 91/4" 13/4" x 111/4" 13/4" x 111/4" 13/4" x 14" 31/2" x 111/4" 31/2" x 14" 31/2" x 14"
24'-0"
51/4" x 71/4" 31/2" x 91/4" 31/2" x 91/4" 31/2" x 91/4" 51/4" x 91/4" 51/4" x 111/4"
Snow Area
115%
13/4" x 91/2" 13/4" x 111/4" 13/4" x 14" 31/2" x 111/4" 31/2" x 117/8" 31/2" x 14" 31/2" x 16"
30LL + 15DL 30'-0"
31/2" x 91/4" 31/2" x 91/4" 31/2" x 91/4" 51/4" x 91/4" 51/4" x 111/4" 51/4" x 117/8" 51/4" x 14"
13/4" x 111/4" 13/4" x 14" 13/4" x 14" 31/2" x 111/4" 31/2" x 14" 31/2" x 16" 31/2" x 18"
36'-0"
31/2" x 91/4" 31/2" x 91/4" 31/2" x 91/4" 51/4" x 91/4" 51/4" x 111/4" 51/4" x 14" 51/4" x 14"
13/4" x 91/2" 13/4" x 111/4" 13/4" x 14" 31/2" x 111/4" 31/2" x 117/8" 31/2" x 14" 31/2" x 16"
24'-0"
31/2" x 91/4" 31/2" x 91/4" 31/2" x 91/4" 51/4" x 91/4" 51/4" x 111/4" 51/4" x 117/8" 51/4" x 14"
13/4" x 111/4" 13/4" x 14" 13/4" x 14" 31/2" x 111/4" 31/2" x 14" 31/2" x 16" 31/2" x 18"
40LL + 15DL 30'-0"
31/2" x 91/4" 31/2" x 91/4" 31/2" x 91/4" 51/4" x 91/4" 51/4" x 111/4" 51/4" x 14" 51/4" x 14"
13/4" x 14" 31/2" x 91/4" 31/2" x 111/4" 31/2" x 14" 31/2" x 16" 31/2" x 18" 31/2" x 20"
36'-0"
31/2" x 91/4" 51/4" x 91/4" 51/4" x 111/4" 51/4" x 117/8" 51/4" x 14" 51/4" x 16"
General Notes
Table is based on: Bearing Requirements
Minimum header support to be 2 trimmers (3") at ends and 71/2" at
• Uniform loads. continuous span supports.
• More restrictive of simple or continuous span. Ratio of short span to
long span should be greater than 0.4 to prevent uplift. Bold, italic header sizes require 3 trimmers (41/2") at ends and 111/4" at
continuous span supports.
• Roof truss framing with 24" soffits.
• Deflection criteria of L/240 live load and L/180 total load.
Also see General Assumptions on page 3.
Sizing Tables
Trus Joist • Microllam® LVL Specifier’s Guide 2020 • August 2003
5
How to Use This Table Colu
Spa mn
1. Determine appropriate ROOF LOAD and HOUSE WIDTH. cing
House Width
Ridge Beams
Roof Load House Column Spacing
(PSF) Width 10'-0" 12'-0" 14'-0" 16'-0" 18'-0" 20'-0" 22'-0" 24'-0"
31/2" x 91/4" 31/2" x 91/4" 31/2" x 91/4" 31/2" x 111/4" 31/2" x 117/8" 31/2" x 14" 31/2" x 16" 31/2" x 16"
24'-0"
51/4" x 91/4" 51/4" x 111/4" 51/4" x 117/8" 51/4" x 14" 51/4" x 14"
31/2" x 91/4" 31/2" x 91/4" 31/2" x 111/4" 31/2" x 111/4" 31/2" x 14" 31/2" x 16" 31/2" x 16" 31/2" x 18"
20LL + 15DL 30'-0"
51/4" x 91/4" 51/4" x 111/4" 51/4" x 14" 51/4" x 14" 51/4" x 16"
Non-Snow Area
31/2" x 91/4" 31/2" x 91/4" 31/2" x 111/4" 31/2" x 14" 31/2" x 14" 31/2" x 16" 31/2" x 18" 31/2" x 18"
36'-0"
125%
51/4" x 91/4" 51/4" x 111/4" 51/4" x 117/8" 51/4" x 14" 51/4" x 16" 51/4" x 16"
31/2" x 91/4" 31/2" x 91/4" 31/2" x 111/4" 31/2" x 111/4" 31/2" x 14" 31/2" x 14" 31/2" x 16" 31/2" x 18"
24'-0"
51/4" x 91/4" 51/4" x 91/2" 51/4" x 111/4" 51/4" x 14" 51/4" x 16"
31/2" x 91/4" 31/2" x 91/4" 31/2" x 111/4" 31/2" x 117/8" 31/2" x 14" 31/2" x 16" 31/2" x 18" 31/2" x 18"
20LL + 20DL 30'-0"
51/4" x 91/4" 51/4" x 111/4" 51/4" x 117/8" 51/4" x 14" 51/4" x 16" 51/4" x 16"
31/2" x 91/4" 31/2" x 91/2" 31/2" x 111/4" 31/2" x 14" 31/2" x 16" 31/2" x 16" 31/2" x 18" 31/2" x 20"
36'-0"
51/4" x 91/4" 51/4" x 111/4" 51/4" x 14" 51/4" x 14" 51/4" x 16" 51/4" x 18"
31/2" x 91/4" 31/2" x 91/4" 31/2" x 111/4" 31/2" x 111/4" 31/2" x 14" 31/2" x 14" 31/2" x 16" 31/2" x 18"
24'-0"
51/4" x 91/4" 51/4" x 91/2" 51/4" x 111/4" 51/4" x 14" 51/4" x 16"
31/2" x 91/4" 31/2" x 91/4" 31/2" x 111/4" 31/2" x 117/8" 31/2" x 14" 31/2" x 16" 31/2" x 18" 31/2" x 18"
25LL + 15DL 30'-0"
51/4" x 91/4" 51/4" x 111/4" 51/4" x 117/8" 51/4" x 14" 51/4" x 16" 51/4" x 16"
31/2" x 91/4" 31/2" x 91/2" 31/2" x 111/4" 31/2" x 14" 31/2" x 16" 31/2" x 18" 31/2" x 20" 31/2" x 20"
36'-0"
51/4" x 91/4" 51/4" x 111/4" 51/4" x 14" 51/4" x 14" 51/4" x 16" 51/4" x 18"
31/2" x 91/4" 31/2" x 91/4" 31/2" x 111/4" 31/2" x 117/8" 31/2" x 14" 31/2" x 16" 31/2" x 16" 31/2" x 18"
24'-0"
51/4" x 91/4" 51/4" x 111/4" 51/4" x 111/4" 51/4" x 14" 51/4" x 14" 51/4" x 16"
Snow Area
115%
31/2" x 91/4" 31/2" x 91/4" 31/2" x 111/4" 31/2" x 14" 31/2" x 16" 31/2" x 16" 31/2" x 18" 31/2" x 20"
30LL + 15DL 30'-0"
51/4" x 91/2" 51/4" x 111/4" 51/4" x 14" 51/4" x 14" 51/4" x 16" 51/4" x 18"
31/2" x 91/4" 31/2" x 111/4" 31/2" x 117/8" 31/2" x 14" 31/2" x 16" 31/2" x 18" 31/2" x 20" 51/4" x 18"
36'-0"
51/4" x 91/4" 51/4" x 111/4" 51/4" x 117/8" 51/4" x 14" 51/4" x 16" 51/4" x 16"
31/2" x 91/4" 31/2" x 91/4" 31/2" x 111/4" 31/2" x 14" 31/2" x 14" 31/2" x 16" 31/2" x 18" 31/2" x 20"
24'-0"
51/4" x 91/4" 51/4" x 111/4" 51/4" x 14" 51/4" x 16" 51/4" x 16"
31/2" x 91/4" 31/2" x 111/4" 31/2" x 117/8" 31/2" x 14" 31/2" x 16" 31/2" x 18" 31/2" x 20" 51/4" x 18"
40LL + 15DL 30'-0"
51/4" x 91/4" 51/4" x 111/4" 51/4" x 117/8" 51/4" x 14" 51/4" x 16" 51/4" x 16"
31/2" x 91/4" 31/2" x 111/4" 31/2" x 14" 31/2" x 16" 31/2" x 18" 31/2" x 20" 51/4" x 18" 51/4" x 20"
36'-0"
51/4" x 91/4" 51/4" x 111/4" 51/4" x 14" 51/4" x 14" 51/4" x 16"
General Notes
Table is based on: Bearing Requirements
Minimum header support to be 2 trimmers (3") at ends and 71/2" at
• Uniform loads. continuous span supports.
• More restrictive of simple or continuous span. Ratio of short span to
long span should be greater than 0.4 to prevent uplift.
Bold, italic beam sizes require 3 trimmers (41/2") at ends and 111/4" at
continuous span supports.
• Deflection criteria of L/240 live load and L/180 total load.
Also see General Assumptions on page 3.
Sizing Tables
6 Trus Joist • Microllam® LVL Specifier’s Guide 2020 • August 2003
Floor Load
40LL + 12DL 13/4" x 14" 31/2" x 111/4" 31/2" x 111/4" 31/2" x 14" 31/2" x 16" 31/2" x 18" 51/4" x 18"
36'-0"
125%
31/2" x 91/4" 51/4" x 91/4" 51/4" x 91/2" 51/4" x 111/4" 51/4" x 14" 51/4" x 16"
13/4" x 111/4" 13/4" x 14" 13/4" x 14" 31/2" x 117/8" 31/2" x 14" 31/2" x 16" 31/2" x 18"
Roof Load 24'-0"
31/2" x 91/4" 31/2" x 91/4" 31/2" x 111/4" 51/4" x 111/4" 51/4" x 117/8" 51/4" x 14" 51/4" x 16"
20LL + 20DL 13/4" x 14" 13/4" x 14" 31/2" x 111/4" 31/2" x 14" 31/2" x 16" 31/2" x 18" 31/2" x 20"
30'-0"
Floor Load 31/2" x 91/4" 31/2" x 111/4" 51/4" x 91/4" 51/4" x 111/4" 51/4" x 14" 51/4" x 16" 51/4" x 18"
40LL + 12DL 31/2" x 91/4" 31/2" x 111/4" 31/2" x 111/4" 31/2" x 14" 31/2" x 16" 31/2" x 18" 51/4" x 18"
36'-0"
51/4" x 91/4" 51/4" x 117/8" 51/4" x 14" 51/4" x 16"
13/4" x 111/4" 13/4" x 14" 13/4" x 14" 31/2" x 117/8" 31/2" x 14" 31/2" x 16" 31/2" x 18"
Roof Load 24'-0"
31/2" x 91/4" 31/2" x 91/4" 31/2" x 111/4" 51/4" x 111/4" 51/4" x 117/8" 51/4" x 14" 51/4" x 16"
25LL + 15DL 13/4" x 14" 31/2" x 111/4" 31/2" x 111/4" 31/2" x 14" 31/2" x 16" 31/2" x 18" 31/2" x 20"
30'-0"
Floor Load 31/2" x 91/4" 51/4" x 91/4" 51/4" x 91/4" 51/4" x 111/4" 51/4" x 14" 51/4" x 16" 51/4" x 18"
40LL + 12DL 31/2" x 91/4" 31/2" x 111/4" 31/2" x 111/4" 31/2" x 14" 31/2" x 16" 31/2" x 20" 51/4" x 18"
36'-0"
51/4" x 91/4" 51/4" x 117/8" 51/4" x 14" 51/4" x 16"
13/4" x 14" 13/4" x 14" 31/2" x 111/4" 31/2" x 14" 31/2" x 14" 31/2" x 18" 31/2" x 20"
Roof Load 24'-0"
31/2" x 91/4" 31/2" x 91/4" 51/4" x 91/4" 51/4" x 111/4" 51/4" x 14" 51/4" x 16"
Snow Area
30LL + 15DL
115%
13/4" x 14" 31/2" x 111/4" 31/2" x 111/4" 31/2" x 14" 31/2" x 16" 31/2" x 18" 51/4" x 18"
30'-0"
Floor Load 31/2" x 91/4" 51/4" x 91/4" 51/4" x 91/2" 51/4" x 111/4" 51/4" x 14" 51/4" x 16"
40LL + 12DL 31/2" x 91/4" 31/2" x 111/4" 31/2" x 117/8" 31/2" x 16" 31/2" x 18" 51/4" x 16" 51/4" x 18"
36'-0"
51/4" x 91/4" 51/4" x 111/4" 51/4" x 117/8" 51/4" x 14"
13/4" x 14" 31/2" x 111/4" 31/2" x 111/4" 31/2" x 14" 31/2" x 16" 31/2" x 18" 31/2" x 20"
Roof Load 24'-0"
31/2" x 91/4" 51/4" x 91/4" 51/4" x 91/4" 51/4" x 111/4" 51/4" x 14" 51/4" x 16" 51/4" x 18"
40LL + 15DL 31/2" x 91/4" 31/2" x 111/4" 31/2" x 117/8" 31/2" x 14" 31/2" x 18" 51/4" x 16" 51/4" x 18"
30'-0"
Floor Load 51/4" x 91/4" 51/4" x 111/4" 51/4" x 117/8" 51/4" x 14"
40LL + 12DL 31/2" x 111/4" 31/2" x 117/8" 31/2" x 14" 31/2" x 16" 51/4" x 16" 51/4" x 18" 51/4" x 20"
36'-0"
51/4" x 91/4" 51/4" x 111/4" 51/4" x 111/4" 51/4" x 14"
General Notes
Table is based on: Bearing Requirements
Minimum header support to be 2 trimmers (3") at ends and 71/2" at
• Uniform loads. continuous span supports.
• More restrictive of simple or continuous span. Ratio of short span to
long span should be greater than 0.4 to prevent uplift. Bold, italic header sizes require 3 trimmers (41/2") at ends and 111/4" at
continuous span supports.
• Roof truss framing with 24" soffits.
• Wall weights of 80 plf.
• Deflection criteria of L/360 live load and L/240 total load at floor.
Also see General Assumptions on page 3.
Sizing Tables
Trus Joist • Microllam® LVL Specifier’s Guide 2020 • August 2003
7
How to Use This Table
Floor Framing Length
1. Determine appropriate FLOOR LOAD.
Span 1 Span 2
2. Find the FLOOR FRAMING LENGTH that meets or exceeds the sum of spans
1 and 2 for the supported floor joists. When floor joists are continuous span,
spans 1 and 2 cannot be less than 40% of the FLOOR FRAMING LENGTH.
If floor joists are simple span (not continuous over the Microllam® LVL beam),
then the FLOOR FRAMING LENGTH may be taken as 80% of the sum of
spans 1 and 2 of the floor joists.
3. Locate COLUMN SPACING.
4. Select Microllam® LVL beam size.
Column
Spacing
General Notes
Table is based on: Bearing Requirements
Minimum beam support to be 2 trimmers (3") at ends and 71/2" at
• Uniform loads. continuous span supports.
• More restrictive of simple or continuous span. Ratio of short span to
long span should be greater than 0.4 to prevent uplift.
Bold, italic beam sizes require 3 trimmers (41/2") at ends and 111/4" at
continuous span supports.
• Deflection criteria of L/360 live load and L/240 total load.
Also see General Assumptions on page 3.
Load Tables
8 Trus Joist • Microllam® LVL Specifier’s Guide 2020 • August 2003
• For deflection limits of L/240 and L/480, multiply live load values by 1.5 and
0.75, respectively. The resulting load shall not exceed the total load shown.
Also see General Assumptions on page 3.
• Uniform loads (beam weight considered) and the more restrictive of simple
or continuous span.
• Deflection criteria of L/180 total load. (For stiffer deflection criteria, L/240
values are also shown.)
Also see General Assumptions on page 3.
• Uniform loads (beam weight considered) and the more restrictive of simple
or continuous span.
• Deflection criteria of L/180 total load. (For stiffer deflection criteria, L/240
values are also shown.)
Also see General Assumptions on page 3.
7 1/4" minimum
depth support
member
required
(HGLTV only)
• Maximum load for top flange hangers may not be increased for duration of load.
General Notes
The hangers listed are manufactured by Simpson Strong-Tie® Company, Inc. Nailing Requirements
For additional information, refer to their literature.
Contact your Trus Joist representative for assistance with other hanger or
• Fill all round and positive angle nail holes with the proper nails.
support conditions. • 10d x 11/2" nails are 9 gauge (0.148" diameter) by 11/2" long.
• Hanger capacity may be more or less than that of the supported member; • 10d nails are 10d common (0.148" diameter) by 3" long.
therefore, both the hanger and the Microllam® LVL capacities must be
checked.
• 16d nails are 16d common (0.162" diameter) by 31/2" long.
• Leave 1/16" clearance (1/8" maximum) between the end of the supported
member and the support member or hanger.
Header Assumptions
THD
PH BPH LBH HD THDH
• Maximum load for top flange hangers may not be increased for duration of load.
General Notes
The hangers listed are manufactured by United Steel Products Company. For Nailing Requirements
additional information, refer to their literature.
Contact your Trus Joist representative for assistance with other hanger or
• Fill all round and dimple nail holes with the proper nails.
support conditions. • 10d x 11/2" nails are 9 gauge (0.148" diameter) by 11/2" long.
• Hanger capacity may be more or less than that of the supported member; • 10d nails are 10d common (0.148" diameter) by 3" long.
therefore, both the hanger and the Microllam® LVL capacities must be
checked.
• 16d nails are 16d common (0.162" diameter) by 31/2" long.
• 16d R.S. nails are 9 gauge (0.148" diameter) by 31/2" long, ring-shank nails.
• Leave 1/16" clearance (1/8" maximum) between the end of the supported
member and the support member or hanger.
Header Assumptions
Top flange
hanger
Face mount
hanger
Column
L4 Protect wood from direct contact L5 Verify Microllam® LVL beam bearing
with concrete length below
• Bearing lengths for Microllam® LVL are based on a bearing stress of 750 psi.
Multiple-Member Connections for Top-Loaded Beams
Trus Joist • Microllam® LVL Specifier’s Guide 2020 • August 2003
17
13/4"
Maximum Uniform Load Applied to Either Outside Member (PLF) Example Problem
Nailed Connection(1)(2) Through-Bolted Connection(3) Structural Wood Screw Connection(4)
Multiple
Assembly 2 Rows 12d 3 Rows 12d
2 Rows 1/2" 2 Rows 1/2" 2 Rows 2 Rows 300 PLF 430 PLF
(see (0.148" x 3.25") (0.148" x 3.25")
Bolts Bolts 1/4" x 31/2" Screw 1/4" x 31/2" Screw
pictures) Common Wire Common Wire
at 24" o.c. at 12" o.c. at 24" o.c. at 12" o.c.
at 12" o.c. at 12" o.c.
A 470 705 505 1,015 500 995
B 355 530 380 760 375 745
C 340 680 330(5) 665(5)
(1) NAILED CONNECTION values may be doubled for 6" on-center or tripled for 4" on-center nail spacing.
(2) NAILED CONNECTION values require an additional row of nails when nail size is smaller than specified above (minimum 0.128" x 3").
(3) A307 bolts with washers required. Bolt holes to be 9/16" maximum.
(4) Screws must have self-drilling tip and minimum bending yield strength of 217,000 psi. Lead holes may be required by local building official.
Solution:
(5) 6" screws required. First, check allowable load tables to verify
that 3 pcs. can carry the total load of
730 plf with proper live load deflection
General Notes criteria. Maximum load applied to either
outside member is 430 plf. For a 3 pc.
• Verify adequacy of beam in uniform load tables on pages 8-13. 13/4" multiple assembly, 2 rows 12d
• Values listed are for 100% stress level. Increase 15% for snow-loaded roof conditions
or 25% for non-snow roof conditions, where code allows.
(31/4") nails at 12" on-center is good for
only 355 plf. Therefore, use 3 rows 12d
(31/4") nails at 12" on-center (good for
• Use specific gravity of 0.5 when designing connections. 530 plf). Alternates: 2 rows 1/2" bolts or
• Beams wider than 7" require special consideration by the design professional. 1/4" x 31/2" screws at 12" on-center.
Minimum Allowable Reaction for 31 ⁄ 2" Microllam® LVL Beam Members(1) (lbs)
3"/12" slope D1 Outside Heel Height
Bearing Beam Depth
41/2" 5" 51/2" 6" 61/2" 7" 71/2" 8" 10"
Sloped
Beam 71/4" 4,470 4,820 4,820 4,820
end cut
depth 91/4" 4,470 4,885 5,205 5,205 5,205 5,205 5,205 5,205
91/2" 4,470 4,885 5,205 5,205 5,205 5,205 5,205 5,205
111/4" 4,470 4,885 5,205 5,205 5,205 5,205 5,205 5,205 5,205
D1 31/2"
117/8" 4,470 4,885 5,205 5,205 5,205 5,205 5,205 5,205 5,205
Wood Plate(2)
14" 4,885 5,205 5,205 5,205 5,205 5,205 5,205 5,205
16" 5,205 5,205 5,205 5,205 5,205 5,205
18" 5,205 5,205 5,205 5,205 5,205
20" 5,205 5,205 5,205
71/4" 4,820 4,820 4,820
91/4" 4,830 5,245 5,665 6,080 6,150 6,150 6,150
Tapered end cut detailed above 91/2" 4,830 5,245 5,665 6,080 6,320 6,320 6,320 6,320
is not allowed with TJI® joists 111/4" 4,830 5,245 5,665 6,080 6,495 6,910 7,325 7,480
51/4"
117/8" 4,830 5,245 5,665 6,080 6,495 6,910 7,325 7,740 7,810
Wood Plate(2)
14" 4,830 5,245 5,665 6,080 6,495 6,910 7,325 7,740 7,810
16" 5,665 6,080 6,495 6,910 7,325 7,740 7,810
Wood Plate Connection 18" 6,080 6,495 6,910 7,325 7,740 7,810
20" 6,910 7,325 7,740 7,810
Sloped
71/4" 4,470 4,820 4,820 4,820
end cut
91/4" 4,470 4,885 5,300 5,715 6,130 6,150 6,150 6,150
Beam
91/2" 4,470 4,885 5,300 5,715 6,130 6,320 6,320 6,320
D1 depth
111/4" 4,470 4,885 5,300 5,715 6,130 6,545 6,960 7,375 7,480
31/2"
117/8" 4,470 4,885 5,300 5,715 6,130 6,545 6,960 7,375 7,895
Column(3)
Wood plate 14" 4,885 5,300 5,715 6,130 6,545 6,960 7,375 9,040
16" 5,715 6,130 6,545 6,960 7,375 9,040
18" 6,130 6,545 6,960 7,375 9,040
20" 6,960 7,375 9,040
(1) For 13/4" and 51/4" beams multiply by 0.5 and 1.5, respectively.
Column Connection (2) Bearing lengths based on Fc⊥ of 425 psi.
(3) Bearing lengths based on Fc⊥ of 750 psi.
Sloped
end cut
Beam General Notes
depth
D1 • No increase for duration of load is permitted.
Allowable Holes
2 x diameter of the largest hole (minimum)
1
/3 depth
Allowed hole zone
1
/3 depth
Maximum Round
Beam Depth
General Notes Hole Size
51/2" 13/4"
• Allowed hole zone suitable for uniformly loaded beams only. 71/4" to 20" 2"
• No holes in cantilevers.
Trus Joist Suppor t Team
Trus Joist • Microllam® LVL Specifier’s Guide 2020 • August 2003
19
1-800-628-3997
www.trusjoist.com
Changing the Way You Build ™
Rim Board
Headers
Beams
arranty Studs and Columns
Product W oducts wi
ll
that its pr
warrants defects in
Trus Joist errors or t
m ma nu facturing ide d the produc
be free fro prov
addition, equacy
an d ma terial. In wa rrants the ad
hip an y
workmans , the comp building.
and used d life of the
y installed d expecte
is correctl normal an
its design for the
of
706
Idaho 83
• Boise,
llard Drive
200 E. Ma 8-3997
1-800-62
___
_________
_________
_________ nt
_________ Tom Den
ig, Preside
Headers
Beams
Columns
1-800-628-3997
www.trusjoist.com
200 E. Mallard Drive (83706)
P.O. Box 60 ◆ Boise, ID 83707 ◆ (208) 364-1200
Headers
Beams
, FrameWorks®, Microllam®, Parallam®, Silent Floor®, TimberStrand®, TJI®, TJ-Beam® and TJ-Xpert® are registered trademarks
and Changing the Way You Build ™, TJ-YardMate™ and Trus Joist™ are trademarks of Trus Joist, A Weyerhaeuser Business, Boise, Idaho.
August 2003 NW/75M Copyright © 2003 by Trus Joist
If this guide is more than one year old,
contact your dealer or Trus Joist rep. Printed in the USA on recycled paper Reorder 2020