Proposed Rules Federal Register


Vol. 73, No. 63

Tuesday, April 1, 2008

This section of the FEDERAL REGISTER • Hand Delivery: U.S. Department of Discussion
contains notices to the public of the proposed Transportation, Docket Operations, M– We have received a report of water
issuance of rules and regulations. The 30, West Building Ground Floor, Room
purpose of these notices is to give interested contamination in the electrical and
W12–140, 1200 New Jersey Avenue, SE., electronic units in the main equipment
persons an opportunity to participate in the Washington, DC 20590, between 9 a.m.
rule making prior to the adoption of the final center. The water contamination caused
rules.
and 5 p.m., Monday through Friday, a central air data computer (CADC–2)
except Federal holidays. and an air data inertial reference unit
For service information identified in (ADIRU–1) to malfunction with eight
DEPARTMENT OF TRANSPORTATION this AD, contact Boeing Commercial cockpit indications of failure. When
Airplanes, P.O. Box 3707, Seattle, loading cargo in rain or snow
Federal Aviation Administration Washington 98124–2207. conditions, water can spill onto the
main deck cargo floor and flow through
14 CFR Part 39 Examining the AD Docket
the power drive units (PDUs). If the
[Docket No. FAA–2008–0376; Directorate You may examine the AD docket on amount of water exceeds the drain
Identifier 2007–NM–322–AD] the Internet at http:// capacity of the PDUs above the main
RIN 2120–AA64 www.regulations.gov; or in person at the equipment center, water can spill onto
Docket Management Facility between 9 the electrical and electronic units. This
Airworthiness Directives; Boeing a.m. and 5 p.m., Monday through water contamination could cause one or
Model 747–100, 747–200B, 747–300, Friday, except Federal holidays. The AD more of the approximately 80 electrical
and 747SR Series Airplanes docket contains this proposed AD, the and electronic units to malfunction. The
regulatory evaluation, any comments malfunction of one or more electrical
AGENCY: Federal Aviation received, and other information. The and electronic units in the main
Administration (FAA), DOT. street address for the Docket Office equipment center, if not corrected,
ACTION: Notice of proposed rulemaking (telephone 800–647–5527) is in the could adversely affect the airplane’s
(NPRM). ADDRESSES section. Comments will be continued safe flight.
SUMMARY: We propose to adopt a new
available in the AD docket shortly after Relevant Service Information
airworthiness directive (AD) for certain receipt.
We have reviewed Boeing Alert
Boeing Model 747–100, 747–200B, 747– FOR FURTHER INFORMATION CONTACT: Service Bulletin 747–25A3368, Revision
300, and 747SR series airplanes that Marcia Smith, Aerospace Engineer, 1, dated June 25, 2007. The service
have been converted by Boeing to the Cabin Safety and Environmental bulletin describes procedures for
Boeing Special Freighter configuration. Systems Branch, ANM–150S, FAA, installing a closeout panel and moisture
This proposed AD would require Seattle Aircraft Certification Office, curtains to protect the electrical and
installation of a closeout panel and 1601 Lind Avenue, SW., Renton, electronic units in the main equipment
moisture curtains for the main Washington 98057–3356; telephone center from water contamination.
equipment center. This proposed AD (425) 917–6484; fax (425) 917–6590. We have also reviewed Boeing Alert
would also require changing the drain Service Bulletin 747–25A3346, dated
SUPPLEMENTARY INFORMATION:
tubes for the power drive units and the September 13, 2007. The service
pitot static tubes and installing larger Comments Invited bulletin describes procedures for
moisture shrouds. This proposed AD changing the PDU drain tubes and pitot
results from a report of water We invite you to send any written static tubes, and installing larger
contamination in the electrical and relevant data, views, or arguments about moisture shrouds to provide additional
electronic units in the main equipment this proposed AD. Send your comments protection from water contamination.
center. We are proposing this AD to to an address listed under the Operators should note that
prevent the malfunction of one or more ADDRESSES section. Include ‘‘Docket No.
accomplishing the actions specified in
electrical and electronic units in the FAA–2008–0376; Directorate Identifier Boeing Alert Service Bulletin 747–
main equipment center, which could 2007–NM–322–AD’’ at the beginning of 25A3346 concurrently with the actions
adversely affect the airplane’s continued your comments. We specifically invite specified in Boeing Alert Service
safe flight. comments on the overall regulatory, Bulletin 747–25A3368 would
DATES: We must receive comments on economic, environmental, and energy necessitate less work than
this proposed AD by May 16, 2008. aspects of this proposed AD. We will accomplishing the service bulletins at
consider all comments received by the different times.
ADDRESSES: You may send comments by
closing date and may amend this
any of the following methods:
proposed AD because of those FAA’s Determination and Requirements
• Federal eRulemaking Portal: Go to
comments. of This Proposed AD
http://www.regulations.gov. Follow the
mstockstill on PROD1PC66 with PROPOSALS

instructions for submitting comments. We will post all comments we We are proposing this AD because we
• Fax: 202–493–2251. receive, without change, to http:// evaluated all relevant information and
• Mail: U.S. Department of www.regulations.gov, including any determined the unsafe condition
Transportation, Docket Operations, M– personal information you provide. We described previously is likely to exist or
30, West Building Ground Floor, Room will also post a report summarizing each develop in other products of the(se)
W12–140, 1200 New Jersey Avenue, SE., substantive verbal contact we receive same type design(s). This proposed AD
Washington, DC 20590. about this proposed AD. would require accomplishing the

VerDate Aug<31>2005 16:36 Mar 31, 2008 Jkt 214001 PO 00000 Frm 00001 Fmt 4702 Sfmt 4702 E:\FR\FM\01APP1.SGM 01APP1
Federal Register / Vol. 73, No. 63 / Tuesday, April 1, 2008 / Proposed Rules 17259

actions specified in the service 2007. However, this proposed AD Costs of Compliance
information described previously. would allow accomplishment of the
original issue of Boeing Alert Service We estimate that this proposed AD
Clarification of Service Information would affect 42 airplanes of U.S.
Bulletin 747–25A3368 before the
Boeing Alert Service Bulletin 747– effective date of the proposed AD only registry. The following table provides
25A3346 specifies prior or concurrent the estimated costs, at an average labor
if the additional work specified in
accomplishment of Boeing Alert Service rate of $80 per work hour, for U.S.
Revision 1 of the service bulletin is
Bulletin 747–25A3368, dated August 25, operators to comply with this proposed
accomplished.
2005, or Revision 1, dated June 25, AD.
ESTIMATED COSTS
Number of
U.S.-
Action Work hours Parts Cost per product Fleet cost
registered
airplanes

Installation for Boeing Alert Service Bul- Up to 10 ................. Up to $11,672 ........ Up to $12,472 ........ 42 Up to $523,824.
letin 747–25A3368.
Installation for Boeing Alert Service Bul- Up to 62 ................. Up to $31,621 ........ Up to $36,581 ........ 42 Up to $1,536,402.
letin 747–25A3346.

Authority for This Rulemaking under the criteria of the Regulatory Unsafe Condition
Flexibility Act. (d) This AD results from a report of water
Title 49 of the United States Code
You can find our regulatory contamination in the electrical and electronic
specifies the FAA’s authority to issue units in the main equipment center. We are
rules on aviation safety. Subtitle I, evaluation and the estimated costs of issuing this AD to prevent the malfunction of
section 106, describes the authority of compliance in the AD Docket. one or more electrical and electronic units in
the FAA Administrator. ‘‘Subtitle VII: List of Subjects in 14 CFR Part 39 the main equipment center, which could
Aviation Programs,’’ describes in more adversely affect the airplane’s continued safe
detail the scope of the Agency’s Air transportation, Aircraft, Aviation flight.
authority. safety, Safety. Compliance
We are issuing this rulemaking under (e) Comply with this AD within the
the authority described in ‘‘Subtitle VII, The Proposed Amendment
compliance times specified, unless already
Part A, Subpart III, Section 44701: Accordingly, under the authority done.
General requirements.’’ Under that delegated to me by the Administrator, Installation of Closeout Panel and Moisture
section, Congress charges the FAA with the FAA proposes to amend 14 CFR part Curtains
promoting safe flight of civil aircraft in 39 as follows:
air commerce by prescribing regulations (f) For the airplanes identified in Boeing
Alert Service Bulletin 747–25A3368,
for practices, methods, and procedures PART 39—AIRWORTHINESS Revision 1, dated June 25, 2007: Within 24
the Administrator finds necessary for DIRECTIVES months after the effective date of this AD,
safety in air commerce. This regulation install the closeout panel and moisture
is within the scope of that authority 1. The authority citation for part 39 curtains for the main equipment center, by
because it addresses an unsafe condition continues to read as follows: accomplishing all of the applicable actions
that is likely to exist or develop on specified in the Accomplishment
Authority: 49 U.S.C. 106(g), 40113, 44701. Instructions of the service bulletin.
products identified in this rulemaking
action. § 39.13 [Amended] Installation of Larger Moisture Shrouds and
Additional Drain Lines
Regulatory Findings 2. The FAA amends § 39.13 by adding
the following new AD: (g) For the airplanes identified in Boeing
We determined that this proposed AD Alert Service Bulletin 747–25A3346, dated
would not have federalism implications Boeing: Docket No. FAA–2008–0376; September 13, 2007: Within 72 months after
under Executive Order 13132. This Directorate Identifier 2007–NM–322–AD. the effective date of this AD, change the drain
proposed AD would not have a tubes for the power drive units and the pitot
Comments Due Date
substantial direct effect on the States, on static tubes and install larger moisture
(a) We must receive comments by May 16, shrouds, by accomplishing all of the
the relationship between the national 2008. applicable actions specified in the
Government and the States, or on the Accomplishment Instructions of the service
distribution of power and Affected ADs
bulletin.
responsibilities among the various (b) None. Note 2: Accomplishing the actions
levels of government. specified in Boeing Alert Service Bulletin
Applicability
For the reasons discussed above, I 747–25A3346 dated September 13, 2007,
certify this proposed regulation: (c) This AD applies to Boeing Model 747– concurrently with the actions specified in
100, 747–200B, 747–300, and 747SR series Boeing Alert Service Bulletin 747–25A3368,
1. Is not a ‘‘significant regulatory airplanes, certificated in any category, as Revision 1, dated June 25, 2007, would
mstockstill on PROD1PC66 with PROPOSALS

action’’ under Executive Order 12866, identified in Boeing Alert Service Bulletin necessitate less work than accomplishing the
2. Is not a ‘‘significant rule’’ under the 747–25A3346, dated September 13, 2007; service bulletins at different times.
DOT Regulatory Policies and Procedures and Boeing Alert Service Bulletin 747–
(44 FR 11034, February 26, 1979), and 25A3368, Revision 1, dated June 25, 2007. Credit for Actions Done According to
3. Will not have a significant Note 1: The affected airplanes are those Previous Issue of the Service Bulletin
economic impact, positive or negative, that have been converted by Boeing to the (h) Actions done before the effective date
on a substantial number of small entities Boeing Special Freighter configuration. of this AD in accordance with Boeing Alert

VerDate Aug<31>2005 16:36 Mar 31, 2008 Jkt 214001 PO 00000 Frm 00002 Fmt 4702 Sfmt 4702 E:\FR\FM\01APP1.SGM 01APP1
17260 Federal Register / Vol. 73, No. 63 / Tuesday, April 1, 2008 / Proposed Rules

Service Bulletin 747–25A3368, dated August optional terminating action for the Comments Invited
25, 2005, are acceptable for compliance with repetitive inspections. This proposed
the corresponding actions required by We invite you to send any written
AD would require an additional relevant data, views, or arguments about
paragraph (f) of this AD, provided that all of inspection to detect cracks of the
the additional work specified in Boeing Alert this proposed AD. Send your comments
Service Bulletin 747–25A3368, Revision 1,
balance weight brackets, applicable to an address listed under the
dated June 25, 2007, is accomplished in related investigative and corrective ADDRESSES section. Include ‘‘Docket No.
accordance with paragraph (f) of this AD. actions, and replacement of a certain FAA–2008–0375; Directorate Identifier
balance weight bracket when it has 2007–NM–272–AD’’ at the beginning of
Alternative Methods of Compliance reached its maximum life limit. This
(AMOCs) your comments. We specifically invite
proposed AD results from a report comments on the overall regulatory,
(i)(1) The Manager, Seattle Aircraft indicating that several reworked balance
Certification Office, FAA, ATTN: Marcia economic, environmental, and energy
weight brackets have exhibited signs of aspects of this proposed AD. We will
Smith, Aerospace Engineer, Cabin Safety and
Environmental Systems Branch, ANM–150S,
premature failure. We are proposing this consider all comments received by the
1601 Lind Avenue, SW., Renton, Washington AD to prevent failure of the balance closing date and may amend this
98057–3356; telephone (425) 917–6484; fax weight brackets of the elevator trim tabs, proposed AD because of those
(425) 917–6590; has the authority to approve which could cause loss of the balance comments.
AMOCs for this AD, if requested using the weight. This could result in incorrect We will post all comments we
procedures found in 14 CFR 39.19. trim during takeoff and landing, and receive, without change, to http://
(2) To request a different method of reduced controllability of the airplane.
compliance or a different compliance time www.regulations.gov, including any
DATES: We must receive comments on personal information you provide. We
for this AD, follow the procedures in 14 CFR
39.19. Before using any approved AMOC on this proposed AD by May 1, 2008. will also post a report summarizing each
any airplane to which the AMOC applies, ADDRESSES: You may send comments by substantive verbal contact we receive
notify your appropriate principal inspector any of the following methods: about this proposed AD.
(PI) in the FAA Flight Standards District • Federal eRulemaking Portal: Go to
Office (FSDO), or lacking a PI, your local http://www.regulations.gov. Follow the Discussion
FSDO. instructions for submitting comments. On June 16, 2004, we issued AD
Issued in Renton, Washington, on March • Fax: 202–493–2251. 2004–13–08, amendment 39–13690 (69
24, 2008. • Mail: U.S. Department of FR 38813, June 29, 2004), for all Short
Ali Bahrami, Transportation, Docket Operations, M– Brothers Model SD3–60 airplanes. That
Manager, Transport Airplane Directorate, 30, West Building Ground Floor, Room AD requires inspection of the welded
Aircraft Certification Service. W12–140, 1200 New Jersey Avenue, SE., joints of the balance weight brackets for
[FR Doc. E8–6613 Filed 3–31–08; 8:45 am] Washington, DC 20590. the left and right elevator trim tabs for
BILLING CODE 4910–13–P
• Hand Delivery: U.S. Department of cracking; repetitive inspections, as
Transportation, Docket Operations, M– applicable; and corrective actions
30, West Building Ground Floor, Room including the eventual replacement of
DEPARTMENT OF TRANSPORTATION W12–140, 1200 New Jersey Avenue, SE., all brackets, which constitutes
Washington, DC 20590, between 9 a.m. terminating action for the repetitive
Federal Aviation Administration and 5 p.m., Monday through Friday, inspections. That AD resulted from a
except Federal holidays. report indicating that a balance weight
14 CFR Part 39 For service information identified in assembly for an elevator trim tab
this AD, contact Short Brothers, detached during landing. We issued that
[Docket No. FAA–2008–0375; Directorate
Identifier 2007–NM–272–AD]
Airworthiness & Engineering Quality, AD to prevent the loss of the balance
P.O. Box 241, Airport Road, Belfast BT3 weight for the elevator trim tab, which
RIN 2120–AA64 9DZ, Northern Ireland. could result in incorrect trim during
Examining the AD Docket takeoff and landing, and reduced
Airworthiness Directives; Short
controllability of the airplane.
Brothers Model SD3–60 Airplanes You may examine the AD docket on On February 11, 2005, we issued AD
AGENCY: Federal Aviation the Internet at http:// 2005–04–13, amendment 39–13985 (70
Administration (FAA), Department of www.regulations.gov; or in person at the FR 9212, February 25, 2005), for all
Transportation (DOT). Docket Management Facility between 9 Short Brothers Model SD3–60 airplanes.
a.m. and 5 p.m., Monday through That AD requires, for certain airplanes,
ACTION: Notice of proposed rulemaking
Friday, except Federal holidays. The AD repetitive inspections for cracking of the
(NPRM). docket contains this proposed AD, the balance weight brackets of the elevator
SUMMARY: The FAA proposes to regulatory evaluation, any comments trim tabs, and replacement of any
supersede two existing airworthiness received, and other information. The cracked bracket with a new or reworked
directives (ADs) that apply to all Short street address for the Docket Office bracket that conforms to the approved
Brothers Model SD3–60 airplanes. One (telephone 800–647–5527) is in the design standard. That AD also provides
of the ADs currently requires inspection ADDRESSES section. Comments will be for an optional terminating action for
of the welded joints of the balance available in the AD docket shortly after the repetitive inspections. That AD
weight brackets for the elevator trim receipt. resulted from reports indicating that
tabs for cracking; repetitive inspections, FOR FURTHER INFORMATION CONTACT: balance weight brackets (which might
mstockstill on PROD1PC66 with PROPOSALS

as applicable; and corrective actions Todd Thompson, Aerospace Engineer, have been installed in accordance with
including the eventual replacement of International Branch, ANM–116, FAA, AD 2004–13–08) have been found
all brackets. The other AD currently Transport Airplane Directorate, 1601 cracked on both the left and right
requires, for certain airplanes, repetitive Lind Avenue, SW., Renton, Washington elevator trim tabs. We issued that AD to
inspections for cracking of the balance 98057–3356; telephone (425) 227–1175; prevent failure of the balance weight
weight brackets and replacement of any fax (425) 227–1149. bracket for the elevator trim tab, which
cracked bracket, and provides for an SUPPLEMENTARY INFORMATION: could cause loss of the balance weight.