Escolar Documentos
Profissional Documentos
Cultura Documentos
a
d io R ou ter
166 kbps
1× ETH, 2× COM, 1× USB
G
e
n
er
a
l
0.1–10 watts, -40 to +70 °C
T
e
c
hn
i
c
alp
a
ra
m
et
e
rs
relevant state-of-the-art concepts have been carefully implemented.
Fast remote access
RipEX provides 24/7 reliable service for mission-critical applications
like SCADA & Telemetry for Utilities, SmartGrid power networks or
SW feature keys
R
a
d
io
p
ar
a
me
te
r
s I
n
te
rf
a
ce
s Transaction networks connecting Lottery terminals or POS or ATMs.
Native IP device
Frequency bands 135-154; 154-174; 215-240; 300-320; 320-340; 340-360; Ethernet 10/100 Base-T Auto MDI/MDIX RJ45 Every unit can serve as the central master, a repeater, a remote terminal,
368-400; 400-432; 432-470; 470-512; 928-960* MHz COM 1 RS232 / 300–115 200 bps DB9F
Channel spacing 6.25 / 12.5 / 25 / 50 kHz COM 2 RS232/RS485 SW configurable DB9F or all of these simultaneously. Anti-collision protocol on Radio channel
Frequency stability +/- 1.0 ppm 300–115 200 bps allows whatever traffic: master or even multi master-slave polling and
Modulation
E
l
e
ct
ri
c
al
* not available yet
Casing Rugged die-cast aluminium
CONTROL
CENTER
RTU PLC
Smart grid
Weather
LAN
Sleep mode 0.1 W
Radio link testing Yes (ping with RSS, Data Quality, Homogenity) LAN
Save mode 2 W COM 2
Watched values Device – Ucc, Temp, PWR, VSWR, *HW Alarm Input.
Radio channel – *RSScom, *DQcom, TXLost[%]
S
W User interfaces – ETH[Rx/Tx], COM1[Rx/Tx],COM2[Rx/Tx]
APPLICATION "B"
COM 1
ver. 1.7
R
a
d
io
mo
d
em
&R
o
u
te
r
C
o
v
er
a
ge U
s
e
rp
ro
t
o
co
ls
One radio hop up to 50 km or more
Modbus, IEC101, DNP3, Comli, DF1, Profibus, SLIP,
Line of sight is not required Siemens 3964(R), IEC104, DNP3/TCP, Modbus TCP and
Carrier output power 0.1 - 10W others
Exceptional data sensitivity SCADA serial protocol addresses are mapped to RipEX
-99 dBm / 83 kbps / 25 kHz / BER 10e-6 addresses
-115 dBm / 10 kbps / 25 kHz / BER 10e-6 TCP(UDP) protocols are handled transparently or using
Any unit can work simultaneously as a repeater Terminal server or TCP proxy
Any IP network can interconnect RipEX units
Each packet is transferred as an acknowledged unicast
Backup routes
Sophisticated anti-collision protocol on Radio channel =>
- Tested alternative paths between two RipEX units simultaneous report by exception and multi-master polling
- Automatic switch-over to backup gateway
Embedded Modbus RTU / Modbus TCP converter
- Unlimited number of Alternative paths
- Alternative paths priorities
D
i
a
gno
s
t
i
cs
&Ne
t
wo
rk
M
an
ag
e
me
n
t S
e
c
ur
i
t
y
Statistic logs for interfaces and communication links
Licensed radio bands
Historical and on-line values displayed in graphs
FEC, interleaving, proprietary data compression
20 periods (e.g. days) of history
CRC32 data integrity control on Radio channel
N
a
t
i
ve
IP
d
ev
i
c
e Watched values (RSS, Ucc, Temp, PWR, etc.) also from
neighbouring units
Proprietary protocol on Radio channel with packet
acknowledgement
Router mode - RipEX works as a standard IP Router with 2 interfaces (Radio and Ethernet) and 2 COM port devices without
SNMP including TRAP alarms
AES256 encryption
any compromise. There is a sophisticated anti-collision protocol on Radio channel, where every single packet is acknowledged. HW Alarm input, HW Alarm output
Firewall - Layer 2 – MAC, Layer 3 – IP, Layer 4 – TCP/UDP
Moreover each unit can simultaneously work as a store-and-forward repeater. Monitoring – on-line analysis of communication over any of
Password - protected access, https web interface
Bridge mode - Packets received on any interface are broadcast to the respective interfaces on all units. Packets received on
the interfaces
SSL (own) certificate up to 2048 bits for https
COM are broadcast to both COM1 and COM2 at remote sites, allowing you to connect 2 RTU's to each remote unit.
IP specialities
Terminal server - encapsulates serial protocol to TCP(UDP) and vice versa and eliminates a transfer of TCP
overhead over Radio channel, 5 independent sessions
TCP proxy - converts TCP to UDP, eliminates transfer of TCP overhead
Subnets - unlimited number of virtual Ethernet interfaces (IP aliases)
R
e
l
i
ab
il
i
ty O
t
h
er
s
VLAN - unlimited number of VLANs assigned to Subnets
Removable sticker plate for your notes
ARP proxy - any IP address simulating (for RTU’s without routing capabilities within the same subnet) Every single unit tested in a climatic chamber as well as in
real traffic
DIN rail, flat, vertical or 19” rack mounting
Separated Rx and Tx antenna connectors *
Heavy-duty or industrial components
Integrated GPS *
Industrial rugged die-cast aluminium case
Hazardous locations: II 3G Ex ic IIC T4 Gc
-40 to +70 oC
E
a
s
yt
oc
on
f
i
gu
re
a
nd
ma
i
n
tai
n D
a
t
as
pe
e
d 3 years warranty * optionally
Basic IP knowledge is sufficient
166 kbps / 50 kHz, 42 kbps / 12,5 kHz, 11 kbps / 6,25 kHz
Web interface or CLI via SSH
Optimization - embedded optimization triples throughput on
Service access via ETH or USB/ETH adapter independently.
Wizards - fast and simple setup
the Radio channel
Stream mode - transmitting starts immediately on the Radio
A
c
c
es
s
or
i
es
All configuration parameters within one page channel, without waiting for the end of the received frame
Fast remote access - only the effective data from remote on COM => zero latency
RipEX-HS – redundant 19‘ hot standby chassis
unit are transferred over the air, html page downloaded from
Auto-speed - receiver is automatically adjusted to the data - Two hot-stand-by standard RipEX units inside
the local unit rate of the incoming frame - Automatic switchover capability on detection of failure
Automatic Firmware and SW keys upgrade from flash disc - For important sites where no single point of failure is required
Wifi adapter – with DHCP for service access
ETH/USB adapter with DHCP for service access
Demo case – the set of 3 units for bench or field tests
S
Wf
e
at
ur
ek
e
ys E
n
e
rg
ys
a
vi
n
gs
Brackets – for flat or vertical mounting
possible direct DIN rail mounting without brackets
Advance features only when and where needed
Sleep mode - 0.1 W, triggered by Digital input
19‘ rack shelves –for single or double units
Coded - Router mode, 83 kbps, COM2, 10W, Backup routes
Save mode - 2 W, wake up by a received packet from
Others – power supplies, antennas, cables…
Free Master-key trial - for 30 days in every RipEX Radio channel or by Digital input