ROCKWELL AUTOMATION
PROCUREMENT SPECIFICATION
PROCUREMENT SPECIFICATION
NOTICE: The specification guidelines in this document are intended to aid in the specification of
products. Specific installations have specific requirements, and Rockwell Automation does not
recommend or intend any specific application based solely upon the guidelines provided here.
Because of the variety of uses for this information, the user of, and those responsible for applying
this information, are responsible for ensuring the acceptability of each application and appropriate
use of the guidelines. In no event will Rockwell Automation be liable for misuse, misapplication or
reliance on these guidelines in connection with any specific application. Rockwell Automation also
disclaims indirect or consequential damages resulting from the use or application of this
information.
Note: To download or view a .doc file version of this procurement specification, please visit:
www.rockwellautomation.com/industries/procurement-specifications
Rockwell Automation
1
[PROJECT NUMBER]
[DATE]
[PROJECT NAME]
[PROJECT LOCATION]
TABLE OF CONTENTS
PART 1 GENERAL.......................................................................................................................... 3
1.01 QUALIFICATIONS.............................................................................................................3
1.02 REFERENCES...................................................................................................................3
1.03 ENVIRONMENTAL REQUIREMENTS...............................................................................3
1.04 SUBMITTALS..................................................................................................................... 3
PART 2 PRODUCTS........................................................................................................................ 3
2.01 MANUFACTURERGENERAL..........................................................................................3
2.02 CONSTRUCTIONGENERAL...........................................................................................4
2.03 DISPLAY FEATURESGENERAL......................................................................................4
2.04 LOGIC FEATURESGENERAL.........................................................................................4
2.05 PROGRAMMINGGENERAL............................................................................................4
2.06 PROGRAMMING TECHNIQUESGENERAL....................................................................5
2.07 RATINGSGENERAL........................................................................................................6
2.08 COMPONENT TERMINALSPECIFIC...............................................................................7
PART 3 EXECUTION....................................................................................................................... 9
3.01 INSTALLATION.................................................................................................................. 9
3.02 INTERFACE WITH OTHER PRODUCTS...........................................................................9
3.03 CLEANING......................................................................................................................... 9
3.04 SPARE MATERIALS..........................................................................................................9
Rockwell Automation
2
[PROJECT NUMBER]
[DATE]
[PROJECT NAME]
[PROJECT LOCATION]
PART 1 GENERAL
1.1
1.2
QUALIFICATIONS
A.
Manufacturer must:
Specialize in manufacturing products specified in this section with minimum 20 years
documented experience
Have service personnel available 24 hours per day through a toll-free phone number
Offer local standard and customized training courses
B.
REFERENCES
A.
1.3
ENVIRONMENTAL REQUIREMENTS
A.
B.
1.4
The operator interface terminal shall be designed to meet the following agency
approvals.
c-UL-us listed
Hazardous Locations Class I, Division II, Groups A,B,C,D certified (specific models)
CE marked for all applicable directives
C-Tick marked for use in continental Australia
KCC marked for use in Korea
The supplier shall conform to specified service conditions during and after installation of
products.
The supplier shall maintain area free of dirt and dust during and after installation of
products.
SUBMITTALS
A.
PART 2 PRODUCTS
Any general specifications (GENERAL) are design requirements for all PanelView Component
terminals covered in this document. Design requirements specific to each model start with section
2.08, which are in addition to the general design requirements.
2.1
MANUFACTURERGENERAL
A.
B.
Rockwell Automation
3
[PROJECT NUMBER]
[DATE]
2.2
[PROJECT NAME]
[PROJECT LOCATION]
CONSTRUCTIONGENERAL
A.
B.
2.3
The operator interface terminal shall operate on power input of 18 to 30 VDC (24 VDC
nominal). A DIN-rail-mounted, AC-to-DC power supply 85 to 265 VAC, 47 to 63 Hz
option shall be available.
DISPLAY FEATURESGENERAL
A.
B.
LOGIC FEATURESGENERAL
A.
PROGRAMMINGGENERAL
A.
Rockwell Automation
4
[PROJECT NUMBER]
[DATE]
[PROJECT NAME]
[PROJECT LOCATION]
Up to 20 displays
Up to 100 alarm messages
Recipe upload/download capabilities
Trending capabilities
Datalogging capabilities
Pushbuttons and selectors
ASCII entry devices
Message displays
Embedded numeric and ASCII variable displays
Analog and digital gauges
Object visibility animation
B.
The operator interface terminal shall have built-in programming software for on-screen
application design and setting adjustments without a PC.
C. The operator interface terminal shall be able to accept applications designed on a PC
with programming software.
D. The operator interface terminal shall be able to secure information with user name and
password protection.
E. The software package shall offer such features as cut, copy, paste and object
import/export capabilities in and between various PanelView Component application
files.
F. The operator interface terminal shall be able to display information in various languages,
including:
Chinese
Portuguese
French
Italian
German
Spanish
Korean
Arabic
Czech
Dutch
Finnish
2.6
PROGRAMMING TECHNIQUESGENERAL
A.
The operator interface terminal shall be capable of being configured offline, using
Connected Components Workbench software.
B.
Require at least an Intel Pentium M 1400 MHz processor with 512MB RAM and with
.NET framework 3.5 installed.
Create applications that can be transferred to the operator interface terminal using a
USB flash or Secure Digital (SD) storage card.
Rockwell Automation
5
[PROJECT NUMBER]
[DATE]
[PROJECT NAME]
[PROJECT LOCATION]
C. Connected Components Workbench shall act as a single software package for various
Component products, coordinating the programming of controllers, the configuration of
devices and the screen design of the operator interface.
D. The operator interface terminal shall have a user-configurable alarm system capable of
popping up an alarm banner on a user screen and presenting information that is critical
to the user and of immediate use.
The programming format shall involve placing input and output objects via the offline
programming and configuration package or the web-enabled software.
F. Input and output objects shall be linked to the logic controller via tags that contain
addressing information to access the data in the logic controller.
G. Capability shall exist for the following:
Recipe management (at least one recipe is supported, more options with DataSets)
Reporting (which provides a detailed report of the PVc application including, but not
limited to, screen shots of all screens present in the application, list of tags,
connections, data usage, etc.).
Going online and then downloading the application to the PanelView terminal or
transferring it via USB/SD.
2.7
RATINGSGENERAL
A.
The operator interface terminal shall be able to withstand conducted susceptibility tests
as outlined in:
Vibration
IEC 60068-2-6
Shock
IEC 60068-2-27
Radiated Emissions
CISPR 11: Group 1, Class A
ESD Immunity
EN 61000-4-2
Radiated RF Immunity
EN 61000-4-3
EFT/B Immunity
EN 61000-4-4
Surge Immunity
EN 61000-4-5
Conducted RF Immunity
EN 61000-4-6
Rockwell Automation
6
[PROJECT NUMBER]
[DATE]
2.8
[PROJECT NAME]
[PROJECT LOCATION]
COMPONENT TERMINALSPECIFIC
A.
The display area shall be 49 mm wide by 14 mm high (1.93 inches wide by 0.55
inches high).
B.
The display area shall be 67 mm wide by 33 mm high (2.64 inches wide by 1.30
inches high).
The display area shall be 95 mm wide by 53.9 mm high (3.74 inches wide by 2.12
inches high).
The back of the operator interface terminal shall have a diagnostic status indicator.
The operator interface terminal shall have a real-time clock with battery backup. The
battery is replaceable.
Rockwell Automation
7
[PROJECT NUMBER]
[DATE]
[PROJECT NAME]
[PROJECT LOCATION]
The display area shall be 115 mm wide by 86 mm high (4.53 inches wide by 3.39
inches high).
The back of the operator interface terminal shall have a diagnostic status indicator.
The operator interface terminal shall have a real-time clock with battery backup. The
battery is replaceable.
The operator interface terminal shall have a slot for a Secure Digital (SD) memory
card for loading the application, for upgrading firmware and for external storage.
E.
The display area shall be 211 mm wide by 158 mm high (8.31 inches wide by 6.22
inches high).
The back of the operator interface terminal shall have a diagnostic status indicator.
The operator interface terminal shall have a real-time clock with battery backup. The
battery is replaceable.
The operator interface terminal shall have a slot for a Secure Digital (SD) memory
card for loading the application, for upgrading firmware and for external storage.
Rockwell Automation
8
[PROJECT NUMBER]
[DATE]
[PROJECT NAME]
[PROJECT LOCATION]
PART 3 EXECUTION
3.1
INSTALLATION
A.
B.
C.
D.
3.2
3.3
The supplier shall provide all required cables, cords and connections for interface with
other control system components.
The supplier shall coordinate size and configuration of enclosure to meet project
requirements.
CLEANING
A.
3.4
SPARE MATERIALS
A.
For each size operator interface terminal being installed, the supplier shall provide:
Antiglare overlay kit
Backlight lamp where operator interface terminal has a field-replaceable backlight
Real-time clock replacement battery where operator interface terminal has a
replaceable battery
END OF SECTION
Rockwell Automation, Rockwell Software, Allen-Bradley, Connected Components Workbench, MicroLogix, Micro800,