Você está na página 1de 2

MARLEY Roofing | South Africa http://www.marleyroofing.co.za/products_ludlow_specs.

php

Overview

Monarch

Modern

Mendip

Double Roman

Double Roman “Plus”

Ludlow

Description
Advanced features
Technical data Ludlow Technical data
Colour Range

Homestead
Nominal tile size: 420 x 332 mm
Fittings & Accessories
Nominal hanging length: 390 mm
Ekonoroof
Nominal tile mass: 4,5 kg
Undertile Membrane
Nominal cover width 294 mm
at lock mid-shuffle position:

The side interlock provides for a practical 2 mm play between the tiles (± 1 mm
either way of the nominal cover) which gives flexibility when setting out the roof
and helps to achieve the correct perpendicular alignment of the courses.

1 de 2 18-02-2010 23:08
MARLEY Roofing | South Africa http://www.marleyroofing.co.za/products_ludlow_specs.php

Minimum roof pitch with 100 mm tile headlap 17,5°

Minimum roof pitch with 75 mm tile headlap 26°

Rafter/Trusses As per structural requirements

Rafters centres 760 mm with 38 x 38 mm batten


(maximum)
900 mm with 38 x 50 mm batten fixed flat

1000 mm with 38 x 50 batten on edge

Note: Above 760 mm the rafter spacing can be


increased only with engineer-designed trusses and
with 38 mm x 50 mm batten of the correct grade. All
structural timber to comply with SANS 10163,1783-2,
1783-4,10149 and 10005.

Underlay Marley high-quality Undertile Membrane is


recommended in all cases. Modern practice has
demonstrated that the underlay is a fundamental part
of a tiled roof at pitches below 26° and for pitches
above 45°, and at all pitches in exposed and coastal
areas.

Tiling data at pitches of 17,5° to 25°

Minimum tile headlap 100 mm

Maximum batten centres 320 mm

Batten per m 2 (net length) 3,13 m

Tiles per m 2 (net) 10,63

Mass of tiles per m 2 ± 47,9 kg


1. The minimum pitch and
minimum headlap must not
Tiling data at pitches of 26° and above
be reduced under any
circumstance. It is always
Minimum tile headlap 75 mm better to raise the safety
factor of the roof by adding a
Maximum batten centres 345 mm full course of tiles and
increasing the tile headlap
Batten per m 2 (net length) 2,9 m evenly on the rafter length.
2. In exposed areas the tile
Tiles per m 2 (net) 9,86 headlap may be increased,
but greater lap is not as
Mass of tiles per m 2 ± 44,4 kg effective as a steeper pitch.

Distance from top edge of first batten 335 mm


to outside edge of fascia board

Distance from top edge of top batten to rafter 25 mm


apex

The figures quoted above are nett. Wastage must be added.


All tiling and fixing to comply with SANS 10062 : 2003 Code of Practice and
with Marley standard fixing specifications.

Cutting and drilling of tiles:


Refer to Marley Health and Safety instruction.

Next

Home - About us - Product Range - Tile Finishes - Cost Comparisons - Roofs of Distinction - Services - Clay Tiles - Contact us

2 de 2 18-02-2010 23:08

Você também pode gostar