Valve Gap
60358-420
.060"
60358-420
.045"
60364-420 ( 4.200)
60364-420 ( 4.200)
Rotor P/N
60364-420 ( 4.200)
60358-420
.030"
787 - 961
GPM
60413-316
.060"
535 - 802
GPM
60323-316 ( 3.160)
60413-316
.045"
478 - 774
GPM
60413-316
.030"
419 - 679
GPM
60323-316 ( 3.160)
60323-316 ( 3.160)
Notes:
1. Yellow Bar denotes the Low Pulse Height Range, dynamic pulse heights in this range are from 100 to 200 PSI at the Valve.
2. Green Bar denotes the Optimal Range with dynamic pulse heights above 200 PSI, less than the maximum recommended pulse and/or velocities below 60 ft/s.
Exceeding the flow range of the green bar may cause large pulses that could damage the pulsers thrust bearings or result in excessive wash of the valve's parts.
3. Red Bar (cross-hatched) denotes the High Wash Zone. APS defines the High Wash Zone for fixed mount pulsers as a flow velocity between 60 - 70 ft/s.
The end of the red bar is the point where the pulser thrust bearing load limit is exceeded.
4. Please Note that Surface Pulses can be significantly impacted by pulse width, pulsation damper settings, depth, mud properties, and other rig conditions.
APS Confidential
SPEC-10040-CUSTOMER REV E
Fixed Mount Pulser Flow Charts - 5.25" Valve
For 8" & 9.5" OD Collar
Predicted Pulse Height at the Valve as a Function of Flow rate for 8.4 Lbs/Gal Mud
600
60413-316 - .030" Gap
500
60413-316 - .060" Gap
400
60358-420 - .045" Gap
300
200
100
0
0
200
400
600
800
1000
1200
This Chart is based on water as the drilling fluid. To predict the pressure for other fluids
scale the pressure by multiplying by the ratio of the fluid density to that of water (specific
weight of the fluid). Example: 10 ppg/8.4 ppg x pressure pulse from chart to estimate
pulse size when using 10 ppg mud.
APS Confidential
SPEC-10040-CUSTOMER REV E
1000
1500
2000
2500
3000
3500
4000
4500
Valve Gap
Rotor P/N
60358-420
1.52 mm
60358-420
1.14 mm
60358-420
.76 mm
60413-316
1.52 mm
60413-316
1.14 mm
60413-316
.76 mm
Notes:
1. Yellow Bar denotes the Low Pulse Height Range, dynamic pulse heights in this range are from 690 to 1,380 kPa at the Valve.
2. Green Bar denotes the Optimal Range with dynamic pulse heights above 1,380 kPa, less than the maximum recommended pulse and/or velocities below 18.3 m/s.
Exceeding the flow range of the green bar may cause large pulses that could damage the pulsers thrust bearings or result in excessive wash of the valve's parts.
3. Red Bar (cross-hatched) denotes the High Wash Zone. APS defines the High Wash Zone for fixed mount pulsers as a flow velocity between 18.3 - 21.3 m/s.
The end of the red bar is the point where the pulser thrust bearing load limit is exceeded.
4. Please Note that Surface Pulses can be significantly impacted by pulse width, pulsation damper settings, depth, mud properties, and other rig conditions.
APS Confidential
SPEC-10040-CUSTOMER REV E
Fixed Mount Pulser Flow Charts - 133 mm (5.25" ) Valve
For 203 mm & 241 mm OD Collar
Predicted Pulse Height at the Valve as a Function of Flow rate for 1000 kg/m 3 Mud
4000
60413-316 - .76 mm Gap
3500
3000
60358-420 - .76 mm Gap
2500
2000
1500
1000
500
0
0
500
1000
1500
2000
2500
3000
3500
4000
4500
This Chart is based on water as the drilling fluid. To predict the pressure for other fluids
scale the pressure by multiplying by the ratio of the fluid density to that of water (specific
3
3
weight of the fluid). Example: 1500 kg/m / 1000 kg/m x pressure pulse from chart to
estimate pulse size when using 1500 kg/m3 mud.
APS Confidential
SPEC-10040-CUSTOMER REV E
100
200
300
400
500
600
700
Valve Gap
60331-316
.060"
433 - 701
GPM
60331-316
.045"
368 - 595
GPM
60323-316 ( 3.160)
60323-316 ( 3.160)
Rotor P/N
60323-316 ( 3.160)
60331-316
.030"
324 - 525
GPM
60363-290
.060"
265 - 467
GPM
60323-290 ( 2.900)
60363-290
.045"
227 - 400
GPM
60363-290
.030"
179 - 315
GPM
60323-290 ( 2.900)
60323-290 ( 2.900)
Notes:
1. Yellow Bar denotes the Low Pulse Height Range, dynamic pulse heights in this range are from 100 to 200 PSI at the Valve.
2. Green Bar denotes the Optimal Range with dynamic pulse heights above 200 PSI, less than the maximum recommended pulse and/or velocities below 60 ft/s.
Exceeding the flow range of the green bar may cause large pulses that could damage the pulsers thrust bearings or result in excessive wash of the valve's parts.
3. Red Bar (cross-hatched) denotes the High Wash Zone. APS defines the High Wash Zone for fixed mount pulsers as a flow velocity between 60 - 70 ft/s.
The end of the red bar is the point where the pulser thrust bearing load limit is exceeded.
4. Please Note that Surface Pulses can be significantly impacted by pulse width, pulsation damper settings, depth, mud properties, and other rig conditions.
APS Confidential
SPEC-10040-CUSTOMER REV E
Fixed Mount Pulser Flow Charts - 4.125" Valve
For 6.25" to 6.75" OD Collar
Predicted Pulse Height at the Valve as a Function of Flow rate for 8.4 Lbs/Gal Mud
700
60363-290 - .030" Gap
60363-290 - .045" Gap
600
500
400
300
200
100
0
0
100
200
300
400
500
600
700
800
This Chart is based on water as the drilling fluid. To predict the pressure for other fluids
scale the pressure by multiplying by the ratio of the fluid density to that of water (specific
weight of the fluid). Example: 10 ppg/8.4 ppg x pressure pulse from chart to estimate
pulse size when using 10 ppg mud.
APS Confidential
SPEC-10040-CUSTOMER REV E
750
1250
1750
2250
2750
Valve Gap
Rotor P/N
60331-316
1.52 mm
60331-316
1.14 mm
60323-316 (80.3mm)
60323-316 (80.3mm)
60331-316
.76 mm
60363-290
1.52 mm
60363-290
1.14 mm
60363-290
.76 mm
Notes:
1. Yellow Bar denotes the Low Pulse Height Range, dynamic pulse heights in this range are from 690 to 1,380 kPa at the Valve.
2. Green Bar denotes the Optimal Range with dynamic pulse heights above 1,380 kPa, less than the maximum recommended pulse and/or velocities below 18.3 m/s.
Exceeding the flow range of the green bar may cause large pulses that could damage the pulsers thrust bearings or result in excessive wash of the valve's parts.
3. Red Bar (cross-hatched) denotes the High Wash Zone. APS defines the High Wash Zone for fixed mount pulsers as a flow velocity between 18.3 - 21.3 m/s.
The end of the red bar is the point where the pulser thrust bearing load limit is exceeded.
4. Please Note that Surface Pulses can be significantly impacted by pulse width, pulsation damper settings, depth, mud properties, and other rig conditions.
APS Confidential
SPEC-10040-CUSTOMER REV E
Fixed Mount Pulser Flow Charts - 105 mm (4.125") Valve
For 159 mm to 171 mm OD Collar
Predicted Pulse Height at the Valve as a Function of Flow rate for 1000 kg/m 3 Mud
4500
60363-290 - .76 mm Gap
60363-290 - 1.14 mm Gap
4000
3500
3000
2500
2000
1500
1000
500
0
0
500
1000
1500
2000
2500
3000
This Chart is based on water as the drilling fluid. To predict the pressure for other fluids scale
the pressure by multiplying by the ratio of the fluid density to that of water (specific weight of
3
3
the fluid). Example: 1500 kg/m / 1000 kg/m x pressure pulse from chart to estimate pulse
3
size when using 1500 kg/m mud.
APS Confidential
SPEC-10040-CUSTOMER REV E
150
250
350
Valve Gap
60330-290 - Discontinued
.060"
199 - 351
GPM
60330-290 - Discontinued
.045"
159 - 280
GPM
60323-290 ( 2.900)
GPM
60323-290 ( 2.900)
Rotor P/N
60323-290 ( 2.900)
60330-290 - Discontinued
.030"
121 - 212
60818-272
.060"
191 - 358
GPM
60323-272 ( 2.720)
60818-272
.045"
154 - 290
GPM
60818-272
.030"
118 - 221
GPM
60323-272 ( 2.720)
60323-272 ( 2.720)
Notes:
1. Yellow Bar denotes the Low Pulse Height Range, dynamic pulse heights in this range are from 100 to 200 PSI at the Valve.
2. Green Bar denotes the Optimal Range with dynamic pulse heights above 200 PSI, less than the maximum recommended pulse and/or velocities below 60 ft/s.
Exceeding the flow range of the green bar may cause large pulses that could damage the pulsers thrust bearings or result in excessive wash of the valve's parts.
3. Red Bar (cross-hatched) denotes the High Wash Zone. APS defines the High Wash Zone for fixed mount pulsers as a flow velocity between 60 - 70 ft/s.
The end of the red bar is the point where the pulser thrust bearing load limit is exceeded.
4. Please Note that Surface Pulses can be significantly impacted by pulse width, pulsation damper settings, depth, mud properties, and other rig conditions.
APS Confidential
SPEC-10040-CUSTOMER REV E
Fixed Mount Pulser Flow Charts - 3.44" Valve
For 4.75" OD Collar
Predicted Pulse Height at the Valve as a Function of Flow rate for 8.4 Lbs/Gal Mud
800
60818-272 - .030" Gap
60330-290 - .030" gap
700
Approximate Pressure Pulse at the Valve (PSI)
600
500
400
300
200
100
0
0
100
200
300
400
This Chart is based on water as the drilling fluid. To predict the pressure for other fluids
scale the pressure by multiplying by the ratio of the fluid density to that of water (specific
weight of the fluid). Example: 10 ppg/8.4 ppg x pressure pulse from chart to estimate
pulse size when using 10 ppg mud.
APS Confidential
SPEC-10040-CUSTOMER REV E
400
600
800
1000
1200
1400
Valve Gap
Rotor P/N
60330-290 - Discontinued
1.52 mm
60330-290 - Discontinued
1.14 mm
60330-290 - Discontinued
.76 mm
456 - 804
LPM
60818-272
1.52 mm
60818-272
1.14 mm
60818-272
.76 mm
446 - 837
LPM
Notes:
1. Yellow Bar denotes the Low Pulse Height Range, dynamic pulse heights in this range are from 690 to 1,380 kPa at the Valve.
2. Green Bar denotes the Optimal Range with dynamic pulse heights above 1,380 kPa, less than the maximum recommended pulse and/or velocities below 18.3 m/s.
Exceeding the flow range of the green bar may cause large pulses that could damage the pulsers thrust bearings or result in excessive wash of the valve's parts.
3. Red Bar (cross-hatched) denotes the High Wash Zone. APS defines the High Wash Zone for fixed mount pulsers as a flow velocity between 18.3 - 21.3 m/s.
The end of the red bar is the point where the pulser thrust bearing load limit is exceeded.
4. Please Note that Surface Pulses can be significantly impacted by pulse width, pulsation damper settings, depth, mud properties, and other rig conditions.
APS Confidential
SPEC-10040-CUSTOMER REV E
Fixed Mount Pulser Flow Charts - 87 mm (3.44") Valve
For 121 mm OD Collar
Predicted Pulse Height at the Valve as a Function of Flow rate for 1000 kg/m 3 Mud
6000
5000
60330-290 - 1.14 mm
Gap
60818-272 - 1.52 mm
Gap
4000
60330-290 - 1.52 mm
Gap
3000
2000
1000
0
0
200
400
600
800
1000
1200
1400
This Chart is based on water as the drilling fluid. To predict the pressure for other fluids
scale the pressure by multiplying by the ratio of the fluid density to that of water (specific
3
3
weight of the fluid). Example: 1500 kg/m / 1000 kg/m x pressure pulse from chart to
3
estimate pulse size when using 1500 kg/m mud.
APS Confidential
SPEC-10040-CUSTOMER REV E
100
200
300
Valve Gap
60712-002
.045"
140 - 242
GPM
60712-002
.030"
106 - 184
GPM
60712-001
.045"
114 - 198
GPM
60712-001
.030"
86 - 148
GPM
Rotor P/N
60323-220 ( 2.200)
60323-220 ( 2.200)
60323-220 ( 2.200)
60323-220 ( 2.200)
Notes:
1. Yellow Bar denotes the Low Pulse Height Range, dynamic pulse heights in this range are from 100 to 200 PSI at the Valve.
2. Green Bar denotes the Optimal Range with dynamic pulse heights above 200 PSI, less than the maximum recommended pulse and/or velocities below 60 ft/s.
Exceeding the flow range of the green bar may cause large pulses that could damage the pulsers thrust bearings or result in excessive wash of the valve's parts.
3. Red Bar (cross-hatched) denotes the High Wash Zone. APS defines the High Wash Zone for fixed mount pulsers as a flow velocity between 60 - 70 ft/s.
The end of the red bar is the point where the pulser thrust bearing load limit is exceeded.
4. Please Note that Surface Pulses can be significantly impacted by pulse width, pulsation damper settings, depth, mud properties, and other rig conditions.
APS Confidential
SPEC-10040-CUSTOMER REV E
600
Approximate Pressure Pulse at the Valve (PSI)
500
400
300
200
100
0
0
100
200
300
This Chart is based on water as the drilling fluid. To predict the pressure for other fluids
scale the pressure by multiplying by the ratio of the fluid density to that of water (specific
weight of the fluid). Example: 10 ppg/8.4 ppg x pressure pulse from chart to estimate pulse
size when using 10 ppg mud.
APS Confidential
SPEC-10040-CUSTOMER REV E
For 89 mm OD Collar
3
1 Second Pulse with 1000 kg/m Mud
200
400
600
800
1000
Valve Gap
60712-002
1.02 mm
530 - 917
LPM
60712-002
.76 mm
402 - 184
LPM
60712-001
1.02 mm
433 - 749
LPM
60712-001
.76 mm
324 - 562
LPM
Rotor P/N
60323-220 (5.59 mm)
60323-220 (5.59 mm)
60323-220 (5.59 mm)
60323-220 (5.59 mm)
Notes:
1. Yellow Bar denotes the Low Pulse Height Range, dynamic pulse heights in this range are from 690 to 1,380 kPa at the Valve.
2. Green Bar denotes the Optimal Range with dynamic pulse heights above 1,380 kPa, less than the maximum recommended pulse and/or velocities below 18.3 m/s.
Exceeding the flow range of the green bar may cause large pulses that could damage the pulsers thrust bearings or result in excessive wash of the valve's parts.
3. Red Bar (cross-hatched) denotes the High Wash Zone. APS defines the High Wash Zone for fixed mount pulsers as a flow velocity between 18.3 - 21.3 m/s.
The end of the red bar is the point where the pulser thrust bearing load limit is exceeded.
4. Please Note that Surface Pulses can be significantly impacted by pulse width, pulsation damper settings, depth, mud properties, and other rig conditions.
APS Confidential
SPEC-10040-CUSTOMER REV E
4500
4000
3500
3000
2500
2000
1500
1000
500
0
0
200
400
600
800
1000
This Chart is based on water as the drilling fluid. To predict the pressure for other fluids
scale the pressure by multiplying by the ratio of the fluid density to that of water (specific
weight of the fluid). Example: 1500 kg/m3 / 1000 kg/m3 x pressure pulse from chart to
estimate pulse size when using 1500 kg/m3 mud.
APS Confidential