Introduction to Parameter Planning

BSSPAR1:
Introduction to Parameter Planning

Nokia Siemens Networks

RN20101EN20GLN0

RN20101EN20GLN0

Introduction to Parameter Planning

Legal Notice
Intellectual Property Rights
All copyrights and intellectual property rights for Nokia Siemens Networks training documentation, product documentation and
slide presentation material, all of which are forthwith known as Nokia Siemens Networks training material, are the exclusive
property of Nokia Siemens Networks . Nokia Siemens Networks owns the rights to copying, modification, translation, adaptation
or derivatives including any improvements or developments. Nokia Siemens Networks has the sole right to copy, distribute,
amend, modify, develop, license, sublicense, sell, transfer and assign the Nokia Siemens Networks training material.
Individuals can use the Nokia Siemens Networks training material for their own personal self-development only, those same
individuals cannot subsequently pass on that same Intellectual Property to others without the prior written agreement of Nokia
Siemens Networks .
The Nokia Siemens Networks training material cannot be used outside of an agreed Nokia Siemens Networks training session
for development of groups without the prior written agreement of Nokia Siemens Networks.

Nokia Siemens Networks

RN20101EN20GLN0

RN20101EN20GLN0

Introduction to Parameter Planning

Module Objectives

At the end of the module, the participant will be able to:

Sketch a BSS Managed Object Hierarchy


Look up the parameters at each level, in the parameter dictionary
Identify parameter value ranges and default settings
Find the changes to objects and parameters, that occur with each
BSS software release

Nokia Siemens Networks

RN20101EN20GLN0

RN20101EN20GLN0

Introduction to Parameter Planning

Managed Object Hierarchy


PLMN

BSC

DAP

BAL

MAL

MALD

BCF

BTS2

BTS1

ADCE

ADCW

TRX

PCU

HOC

PCM

RA

LAPD

SEG

POC

RTSL

Nokia Siemens Networks

RN20101EN20GLN0

The BSC radio network configuration management provides the operator with the
means of controlling the radio network configuration data stored in the BSS Radio
Network Configuration Database (BSDATA).
At the top-level user interface of the NSN OSS, the management of various network
elements and managed objects is structured in the hierarchical manner as shown in
the figure.
The PLMN consists of BSC, MSC, SGSN and other objects as its children. We are
going to discuss the objects under the BSC. The objects may represent real network
elements (e.g. BCF, BTS) or functional objects that represent a function of a unit
(e.g. Handover Control, Power Control).
The object SEG is not seen as a separate object class but some of the BTS level
parameters have a significance only at the SEG level. A SEG consists of one or
more BTS objects. For example, in a network with Common BCCH, one BTS with
BCCH and the other BTS without the BCCH, both belong to one logical segment.
The NetAct (OSS) keeps a record of the parameters, states, configuration, and other
relevant details of each cell in the database. In doing so, the operator can see via the
OSS the current parameters.

RN20101EN20GLN0

Introduction to Parameter Planning

Example from Parameter Dictionary


Parameter name

Rxlev Access Min

Abbreviated name

rxLevAccessMin

Managed object

BTS

Multiplicity

Description

With this parameter you define the minimum power level an MS has to receive before it is allowed to
access the cell.

Additional information

Range and step

-110...-47 dBm, step 1 dBm

Formula for getting internal value

internal_value = (gui_value + 110)

Default value

-105 dBm

Default value notes

Required on Creation

optional

Related functions

Modification

Online

Modified

Related parameters

Parameter relationships

Related options

Related features

Interfaces

References

RACApp <-> RAC


Planner <-> RAC
RAC <-> Optimizer
RAC <-> BSC
3GPP Reference: 44.018, 45.008

MML Commands

EQG, EQO

MML Abbreviated Name

RXP

MML Full Name

rxlev access min

Segment Level Parameter

true

File Based Provisioning supported

true

Nokia Siemens Networks

RN20101EN20GLN0

RN20101EN20GLN0

Introduction to Parameter Planning

PRFILE, FIFILE and PAFILE parameters


PRFILE (General Parameter File)
Standard features
Optional features
Interrogate with MML command ZWOS

FIFILE (Feature Information Control File)


Stores optional parameters from the PRFILE
Interrogate with MML command ZWOI

PAFILE (BSC Control Parameter File)


GSM-BSC parameters
GSM Timers
Interrogate with MML command ZEGO

Nokia Siemens Networks

RN20101EN20GLN0

RN20101EN20GLN0

Introduction to Parameter Planning

Features & Activation status

ZWOI command

ZWOS command
7

Nokia Siemens Networks

RN20101EN20GLN0

RN20101EN20GLN0

Introduction to Parameter Planning

GSM-BSC Parameters & Timers

ZEGO command
8

Nokia Siemens Networks

RN20101EN20GLN0

RN20101EN20GLN0

Introduction to Parameter Planning

Viewing parameters
Using NetAct CM Editor

Nokia Siemens Networks

RN20101EN20GLN0

RN20101EN20GLN0

Introduction to Parameter Planning

Viewing parameters
with MML Commands in BSC
ZEQO Output

10

Nokia Siemens Networks

RN20101EN20GLN0

RN20101EN20GLN0

10

Introduction to Parameter Planning

Exporting parameters
Using NetAct CM Ops Manager

11

Nokia Siemens Networks

RN20101EN20GLN0

RN20101EN20GLN0

11

Introduction to Parameter Planning

New objects & parameters

12

Nokia Siemens Networks

RN20101EN20GLN0

Kygouygoliugli

RN20101EN20GLN0

12

Introduction to Parameter Planning

Call Phases (MOC case)


MS

BTS

BSC

CH. REQUEST (RACH)


IMMEDIATE ASSIGN(AGCH)

Phase 1 : Paging, initial MS

SERVICE REQUEST (SDCCH)


AUTHENTICATION (SDCCH)
CIPHERING MODE (SDCCH)
TMSI REALLOCATION (SDCCH)

Phase 2 : MM signalling
Phase 8 : Ciphering
Phase 2 : MM signalling

SETUP (SDCCH)
ASSIGNMENT (SDCCH-FACCH)
CH.RELEASE
ALERTING & CONNECT
(FACCH)
CONN. ACK. and MEASUREMENT
DISCONNECT & RELEASE
(FACCH)

Phase 3 : Basic assignment


Phase 4 : Release
Phase 2 : MM signalling
Phase 15 : Conversation
Phase 4 : Release

Signalling procedures are used during the 15 phases in a basic call


Certain parameters influence the setting up and the release of a call
13

Nokia Siemens Networks

RN20101EN20GLN0

RN20101EN20GLN0

13